1.
When irradiating a polymer gel dosimeter to relatively high doses, edge enhancing effects (overshoots) may be noticed near dose gradients, resulting in a loss of spatial dose integrity. These overshoots are believed to be a consequence of monomers diffusing into the high-dose region, where they react with long-living macroradicals. Macroradicals may also be responsible for the temporal chemical instability of post-irradiation polymerization that occurs in the polymer gel dosimeter. In this study, a mathematical model is proposed that simulates the edge enhancing effect. The model is based on the hypothesis that the macroradicals are responsible for both the temporal instability and loss of spatial dose integrity. All input parameters for the model are obtained from independent experiments. The edge enhancing effect is studied both experimentally and theoretically for polymer gel dosimeters with various gelatin concentrations. The change in the edge enhancement is also investigated over post-irradiation time. Comparisons between polymer gel measurements and simulations confirm the hypothesis that there is a strong relation between the spatial and temporal instabilities.  相似文献   

2.
This study reports new N-isopropylacrylamide (NIPAM) polymer gel recipes with increased dose sensitivity and improved dose resolution for x-ray CT readout. NIPAM can be used to increase the solubility of N, N'-methylenebisacrylamide (Bis) in aqueous solutions from approximately 3% to 5.5% by weight, enabling the manufacture of dosimeters containing up to 19.5%T, which is the total concentration of NIPAM and Bis by weight. Gelatin is shown to have a mild influence on dose sensitivity when gels are imaged using x-ray CT, and a stronger influence when gels are imaged optically. Phantoms that contain only 3% gelatin and 5 mM tetrakis hydroxymethyl phosphonium chloride are sufficiently stiff for dosimetry applications. The best cosolvent-free gel formulation has a dose sensitivity in the linear range (~0.88 H Gy(-1)) that is a small improvement compared to the best NIPAM-based gels that incorporate isopropanol as a cosolvent (~0.80 H Gy(-1)). This new gel formulation results in enhanced dose resolution (~0.052 Gy) for x-ray CT readout, making clinical applications of this imaging modality more feasible.  相似文献   

3.
A new method for the evaluation of radiotherapy 3D polymer gel dosimeters has been developed using ultrasound to assess the significant structural changes that occur following irradiation of the dosimeters. The ultrasonic parameters of acoustic speed of propagation, attenuation and transmitted signal intensity were measured as a function of absorbed radiation dose. The dose sensitivities for each parameter were determined as 1.8 x 10(-4) s m(-1) Gy(-1), 3.9 dB m(-1) Gy(-1) and 3.2 V(-1) Gy(-1) respectively. All parameters displayed a strong variation with absorbed dose that continued beyond absorbed doses of 15 Gy. The ultrasonic measurements demonstrated a significantly larger dynamic range in dose response curves than that achieved with previously published magnetic resonance imaging (MRI) dose response data. It is concluded that ultrasound shows great potential as a technique for the evaluation of polymer gel dosimeters.  相似文献   

4.
Two oxygen scavengers have been successfully tested to produce normoxic polymer gel dosimeters under normal atmospheric conditions. The first is ascorbic acid and the second is a chloride (also sulfate) salt of tetrakis (hydroxymethyl) phosphonium. These antioxidants, added to the dosimeter during gel preparation, chemically remove dissolved oxygen that otherwise inhibits propagation of the polymerization reaction during irradiation of the dosimeter. These gel dosimeters are radiosensitive after manufacture under normoxic conditions. However, we show herein that the accuracy of the dosimetric measurement is compromised due to chemical reactions of the antioxidant with radicals. In addition, we provide evidence that both antioxidant and oxygen act as radical scavengers that affect the amount of polymer formed in the gel dosimeter. This can result in important dose inaccuracies in both methacrylic acid-based and acrylamide-based normoxic dosimeter gels.  相似文献   

5.
The radiological properties of the normoxic polymer gel dosimeters MAGIC, MAGAS, and MAGAT [methacrylic and ascorbic acid in gelatin initiated by copper; methacrylic acid gelatine gel with ascorbic acid; and methacrylic acid gelatine and tetrakis (hydroxymethyl) phosphonium chloride, respectively] have been investigated. The radiological water equivalence was determined by comparing the polymer gel macroscopic photon and electron interaction cross sections over the energy range from 10 keV to 20 MeV and by Monte Carlo modeling of depth doses. Normoxic polymer gel dosimeters have a high gelatine and monomer concentration and therefore mass density (kg m(-3)) up to 3.8% higher than water. This results in differences between the cross-section ratios of the normoxic polymer gels and water of up to 3% for the attenuation, energy absorption, and collision stopping power coefficient ratios through the Compton dominant energy range. The mass cross-section ratios were within 2% of water except for the mass attenuation and energy absorption coefficients ratios, which showed differences with water of up to 6% for energies less than 100 keV. Monte Carlo modeling was undertaken for the polymer gel dosimeters to model the electron and photon transport resulting from a 6 MV photon beam. The absolute percentage differences between gel and water were within 1% and the relative percentage differences were within 3.5%. The results show that the MAGAT gel formulation is the most radiological water equivalent of the normoxic polymer gel dosimeters investigated due to its lower mass density measurement compared with MAGAS and MAGIC gels.  相似文献   

6.
Mather ML  Baldock C 《Medical physics》2003,30(8):2140-2148
A novel imaging system for investigation of absorbed dose distributions in radiotherapy polymer gel dosimeters using ultrasound is introduced. A prototype transmission ultrasound computed tomography (UCT) imaging system is developed and evaluated. The imaging capabilities of the system are assessed through investigation of an irradiated polyacrylamide gel test phantom. Images based on transmitted signal amplitude and time of flight (TOF) of the ultrasonic signal through the phantom are reconstructed using a filtered backprojection technique. In general, the reconstruction of the square field in the TOF image was superior to the transmission image, however, transmission images displayed superior contrast to TOF images. The image quality achieved with this prototype system is promising and could be significantly enhanced through improvements, in particular through the development of more sophisticated experimental equipment. It is concluded that UCT is a viable technique for imaging absorbed dose distributions in polymer gel dosimeters and investigations are continuing to further improve the system.  相似文献   

7.
Xu Y  Wuu CS  Maryanski MJ 《Medical physics》2004,31(11):3024-3033
Performance analysis of a commercial three-dimensional (3-D) dose mapping system based on optical CT scanning of polymer gels is presented. The system consists of BANG 3 polymer gels (MGS Research, Inc., Madison, CT), OCTOPUS laser CT scanner (MGS Research, Inc., Madison, CT), and an in-house developed software for optical CT image reconstruction and 3-D dose distribution comparison between the gel, film measurements and the radiation therapy treatment plans. Various sources of image noise (digitization, electronic, optical, and mechanical) generated by the scanner as well as optical uniformity of the polymer gel are analyzed. The performance of the scanner is further evaluated in terms of the reproducibility of the data acquisition process, the uncertainties at different levels of reconstructed optical density per unit length and the effects of scanning parameters. It is demonstrated that for BANG 3 gel phantoms held in cylindrical plastic containers, the relative dose distribution can be reproduced by the scanner with an overall uncertainty of about 3% within approximately 75% of the radius of the container. In regions located closer to the container wall, however, the scanner generates erroneous optical density values that arise from the reflection and refraction of the laser rays at the interface between the gel and the container. The analysis of the accuracy of the polymer gel dosimeter is exemplified by the comparison of the gel/OCT-derived dose distributions with those from film measurements and a commercial treatment planning system (Cadplan, Varian Corporation, Palo Alto, CA) for a 6 cm x 6 cm single field of 6 MV x rays and a 3-D conformal radiotherapy (3DCRT) plan. The gel measurements agree with the treatment plans and the film measurements within the "3%-or-2 mm" criterion throughout the usable, artifact-free central region of the gel volume. Discrepancies among the three data sets are analyzed.  相似文献   

8.
9.
Changes in the linear attenuation coefficient of polymer gel dosimeters post-irradiation enable the imaging of dose distributions by x-ray computed tomography (CT). Various compositions of polymer gel dosimeters manufactured from acrylamide (AA), and N,N'-methylene-bis-acrylamide (BIS) comonomers and gelatin or agarose gelling agents were investigated. This work shows that increasing the comonomer concentration increases the CT-dose sensitivity of the polymer gel dosimeter. This can be further increased by replacing gelatin with agarose. Varying the gelatin concentration however does not significantly change the CT-dose sensitivity. Among the compositions studied, dose resolution (D(delta)95%) was found to be optimal for polymer gel dosimeters comprising 5% gelatin, 3% AA, 3% BIS and 89% water.  相似文献   

10.
Measurement errors in polymer gel dosimetry can originate either during irradiation or scanning. One concern related to the exothermic nature of polymerization reaction was that the heat released in polymer gel dosimeters during irradiation modifies their dose response. In this paper, the effect of heat released from the exothermal polymerization reaction on the dose response of a number of dosimeters was studied. In addition, we investigated whether heat-generated geometric distortion existed in newly proposed gel dosimeters that contain highly thermoresponsive polymers. Our results suggest that despite a significant internal temperature increase in some gel compositions, their dose responses are not affected when oxygen is well expelled mechanically from the gel mixture. We also report on significant pre-irradiation instability in some recently developed polymer gel dosimeters but that geometric distortions were not observed. Data obtained by a set of small calibration vials are compared to those obtained from larger phantoms, and potential physicochemical causes of deviations between them are identified.  相似文献   

11.
Polymer gel dosimeters offer a wide range of potential applications in the three-dimensional verification of complex dose distribution such as in intensity-modulated radiotherapy (IMRT). Until now, however, polymer gel dosimeters have not been widely used in the clinic. One of the reasons is that they are difficult to manufacture. As the polymerization in polymer gels is inhibited by oxygen, all free oxygen has to be removed from the gels. For several years this was achieved by bubbling nitrogen through the gel solutions and by filling the phantoms in a glove box that is perfused with nitrogen. Recently another gel formulation was proposed in which oxygen is bound in a metallo-organic complex thus removing the problem of oxygen inhibition. The proposed gel consists of methacrylic acid, gelatin, ascorbic acid, hydroquinone and copper(II)sulphate and is given the acronym MAGIC gel dosimeter. These gels are fabricated under normal atmospheric conditions and are therefore called 'normoxic' gel dosimeters. In this study, a chemical analysis on the MAGIC gel was performed. The composition of the gel was varied and its radiation response was evaluated. The role of different chemicals and the reaction kinetics are discussed. It was found that ascorbic acid alone was able to bind the oxygen and can thus be used as an anti-oxidant in a polymer gel dosimeter. It was also found that the anti-oxidants N-acetyl-cysteine and tetrakis(hydroxymethyl)phosphonium were effective in scavenging the oxygen. However, the rate of oxygen scavenging is dependent on the anti-oxidant and its concentration with tetrakis(hydroxymethyl)phosphonium being the most reactive anti-oxidants. Potentiometric oxygen measurements in solution provide an easy way to get a first impression on the rate of oxygen scavenging. It is shown that cupper(II)sulphate operates as a catalyst in the oxidation of ascorbic acid. We, therefore, propose some new normoxic gel formulations that have a less complicated chemical formulation than the MAGIC gel.  相似文献   

12.
Modelling of post-irradiation events in polymer gel dosimeters.   总被引:1,自引:0,他引:1  
The nuclear magnetic resonance (NMR) spin-spin relaxation time (T2) is related to the radiation-dependent concentration of polymer formed in polymer gel dosimeters manufactured from monomers in an aqueous gelatin matrix. Changes in T2 with time post-irradiation have been reported in the literature but their nature is not fully understood. We investigated those changes with time after irradiation using FT-Raman spectroscopy and the precise determination of T2 at high magnetic field in a polymer gel dosimeter. A model of fast exchange of magnetization taking into account ongoing gelation and strengthening of the gelatin matrix as well as the polymerization of the monomers with time is presented. Published data on the changes of T2 in gelatin gels as a function of post-manufacture time are used and fitted closely by the model presented. The same set of parameters characterizing the variations of T2 in gelatin gels and the increasing concentration of polymer determined from FT-Raman spectroscopy are used successfully in the modelling of irradiated polymer gel dosimeters. Minimal variations in T2 in an irradiated PAG dosimeter are observed after 13 h.  相似文献   

13.
A technique is described for investigation of the ultrasonic attenuation coefficient for evaluation of absorbed dose in polymer gel dosimeters. Using this technique the attenuation coefficient as a function of absorbed dose in PAG and MAGIC polymer gel dosimeters was measured. The ultrasonic attenuation coefficient dose sensitivity for PAG was found to be 2.9 +/- 0.3 dB m(-1) Gy(-1) and for MAGIC gel 4.2 +/- 0.3 dB m(-1) Gy(-1). Unlike previous studies of ultrasonic attenuation in polymer gel dosimeters this technique enables a direct measure of the attenuation coefficient.  相似文献   

14.
Post-irradiation changes in the linear attenuation coefficient, mu, of polymer gel dosimeters give rise to a change which can be measured with x-ray computed tomography. Polymer gel dosimeters were manufactured consisting of 3% (by weight) acrylamide and 3% N,N'-methylene-bis-acrylamide comonomers dissolved in aqueous gelatin (5% gelatin by total weight and 89% de-ionized distilled water). Mu was measured in a collimated radiation beam of photons from an 241Am source. Density, rho, of polymer gel dosimeters was measured using volumetric flasks with capillary stoppers. The measured post-irradiation data of mu was plotted against the data of rho for different batches, and linear least squares fits gave r2 values of 0.99605 and 0.99953, with P values of less than 0.001. This confirms that the post-irradiation change in mu is proportional to that of rho. The change in rho implies a change in volume regardless of the evaluation modality of the polymer gel dosimeter.  相似文献   

15.
The change in linear attenuation coefficient with absorbed dose has been investigated for aqueous polyacrylamide, gelatine and tetrakis (PAGAT) and aqueous methacrylic acid, gelatine and tetrakis (MAGAT) normoxic polymer gel dosimeters using tetrakis (hydroxy methyl) phosphonium chloride as the antioxidant. The measured linear attenuation coefficient increased linearly with absorbed dose up to 15 Gy for PAGAT gels and 10 Gy for MAGAT gels. Computerized tomography (CT) numbers or Hounsfield units (H) were calculated from the linear attenuation coefficients and compared with values obtained using a CT scanner. Both calculated and measured CT numbers followed a similar pattern when fitted with a biexponential curve. The CT numbers obtained from linear attenuation measurements were found to be greater than that obtained with the CT scanner for both PAGAT and MAGAT polymer gels. The H-dose sensitivities of the MAGAT and PAGAT polymer gel dosimeters measured on a CT scanner were calculated to be (0.85 +/- 0.08) H Gy(-1) and (0.31 +/- 0.03) H Gy(-1), respectively. The H-dose sensitivities of the MAGAT and PAGAT polymer gel dosimeters from attenuation measurements were found to be (1.10 +/- 0.66) H Gy(-1) and (0.34 +/- 0.01) H Gy(-1), respectively.  相似文献   

16.
Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range investigated. The ultrasonic attenuation dose sensitivity at 4 MHz in MAGIC gels was determined to be 4.7 +/- 0.3 dB m(-1) Gy(-1) and for PAG 3.9 +/- 0.3 dB m(-1) Gy(-1). Ultrasonic speed dose sensitivities were 0.178 +/- 0.006 m s(-1) Gy(-1) for MAGIC gel and -0.44 +/- 0.02 m s(-1) Gy(-1) for PAG. Density and compressional elastic modulus were investigated to explain the different sensitivities of ultrasonic speed to radiation for PAG and MAGIC gels. The different sensitivities were found to be due to differences in the compressional elastic modulus as a function of dose for the two formulations. To understand the physical phenomena underlying the increase in ultrasonic attenuation with dose, the viscoelastic properties of the gels were studied. Results suggest that at ultrasonic frequencies, attenuation in polymer gel dosimeters is primarily due to volume viscosity. It is concluded that ultrasonic attenuation significantly increases with absorbed dose. Also, the ultrasonic speed in polymer gel dosimeters is affected by changes in dosimeter elastic modulus that are likely to be a result of polymerization. It is suggested that ultrasound is a sufficiently sensitive technique for polymer gel dosimetry.  相似文献   

17.
Polymer gel dosimeters of different formulations were manufactured from different monomers of acrylamide, acrylic acid, methacrylic acid, 1-vinyl-2-pyrrolidinone, 2-hydroxyethyl methacrylate and 2-hydroxyethyl acrylate. Gelatin and agarose were used as the gelling agents and N,N'-methylene-bis-acrylamide was used as a co-monomer in each polymer gel dosimeter. The T2 dependence of each dosimeter was analysed using a model of fast exchange of magnetization. The influence of the half-dose and the apparent T2 of the polymer-proton pool on the dose resolution (Dpdelta) were examined. Comparisons are made with the commonly employed R2-dose sensitivity. Differences exist suggesting that experiments reported in the literature using what were thought to be more optimal dosimeters may not actually be so. Based on Dpdelta of each formulation, conclusions are drawn on the optimal formulation required for a specific range of absorbed doses. In addition, information about the extent of polymerization of the monomers used along with some characteristics of the polymer network formed are reported. The influence of the concentration of monomers and gelling agent was subsequently evaluated using a model of fast exchange of magnetization. Based on these calculations, further improvement in Dpdelta can be expected.  相似文献   

18.
Polymer gel dosimeters offer a wide range of applications in the three-dimensional verification of complex radiation dose distributions such as in intensity-modulated radiotherapy (IMRT). With the release of polymer gel dosimeters that can be fabricated in normal atmospheric ('normoxic') conditions, the gel manufacturing process has been significantly simplified. Gel dosimeters are calibrated by use of a series of calibration vials irradiated with known doses or by use of a calibration phantom with a known dose distribution. The overall accuracy of the polymer gel dosimeters is determined by different dosimetric properties. In this study, we show the influence of the temperature history during storage of the gel dosimeter on the dose response curve for two gel dosimeters using the monomers acrylamide/N,N'-methylene-bis-acrylamide (nPAG) and methacrylic acid (nMAG) respectively and bis[tetrakis(hydroxymethyl)phosphonium]sulphate (THP) as antioxidant in both gel dosimeters. This study reveals that differences in temperature history after fabrication of normoxic polymer gel dosimeters may compromise the dosimetric accuracy. It was found that the acrylamide based gel dosimeter (nPAG) is less dependent on the post-manufacture temperature history than the methacrylic acid based gel dosimeter (nMAG). The importance of an equal temperature history for the gel dosimeter and calibration vials is emphasized by this study. A reproducibility study has also been performed on the nPAG gel dosimeter when additional efforts are made to control the temperature changes upon cooling.  相似文献   

19.
There is a lack of standardized methodology to perform dose calculations for targeted radionuclide therapy and at present no method exists to objectively evaluate the various approaches employed. The aim of the work described here was to investigate the practicality and accuracy of calibrating polymer gel dosimeters such that dose measurements resulting from complex activity distributions can be verified. Twelve vials of the polymer gel dosimeter, 'MAGIC', were uniformly mixed with varying concentrations of P-32 such that absorbed doses ranged from 0 to 30 Gy after a period of 360 h before being imaged on a magnetic resonance scanner. In addition, nine vials were prepared and irradiated using an external 6 MV x-ray beam. Magnetic resonance transverse relaxation time, T2, maps were obtained using a multi-echo spin echo sequence and converted to R2 maps (where T2 = 1/R2). Absorbed doses for P-32 irradiated gel were calculated according to the medical internal radiation dose schema using EGSnrc Monte Carlo simulations. Here the energy deposited in cylinders representing the irradiated vials was scored. A relationship between dose and R(2) was determined. Effects from oxygen contamination were present in the internally irradiated vials. An increase in O2 sensitivity over those gels irradiated externally was thought to be a result of the longer irradiation period. However, below the region of contamination dose response appeared homogenous. Due do a drop-off of dose at the periphery of the internally irradiated vials, magnetic resonance ringing artefacts were observed. The ringing did not greatly affect the accuracy of calibration, which was comparable for both methods. The largest errors in calculated dose originated from the initial activity measurements, and were approximately 10%. Measured R2 values ranged from 5-35 s(-1) with an average standard deviation of 1%. A clear relationship between R2 and dose was observed, with up to 40% increased sensitivity for internally irradiated gels. Curve fits to the calibration data followed a single exponential function. The correlation coefficients for internally and externally irradiated gels were 0.991 and 0.985, respectively. With the ability to accurately calibrate internally dosed polymer gels, this technology shows promise as a means to evaluate dosimetry methods, particularly in cases of non-uniform uptake of a radionuclide.  相似文献   

20.
Radiation-induced chemical changes in polyacrylamide gels (PAGs) used in 3D radiation dosimetry have been studied using Fourier transform Raman spectroscopy. Consumption of monomer and crosslinker were characterized for polymer gel dosimeters with initial fraction of crosslinker (%C) varying from to 100%. Results indicate that the rate of monomer/crosslinker consumption is highly nonlinear over %C. This indicates that maximum polymer gel dosimeter sensitivity (i.e. slope of the monomer consumption curves) is dependent not only on initial %C but also on dose range. For low-dose regions (<5 Gy) 30%C PAGs are the most sensitive dosimeters, their maximum sensitivity being a factor of 1.8 times greater than 50%C PAGs. In mid-dose range (S-15 Gy), however, 50%C PAGs are the most sensitive dosimeters, being potentially a factor of 1.3 more sensitive than any other PAG studied. In high-dose regions (> 15 Gy) 70%C PAGs are at least 1.5 times more sensitive than any other PAG studied. A qualitative model is presented which helps to explain the variation in overall monomer consumption rate as a function of initial %C. The variation in the shapes (i.e. mathematical course) of the consumption curves for different %C PAGs is, in part, qualitatively explained by consideration of the average number of monomer to crosslinker molecules available for reaction in each PAG as it is irradiated to higher doses. Finally, we demonstrate the importance of an existing polymer network on the subsequent monomer consumption rate in a 50%C PAG.  相似文献   