1.
ImmunoCard STAT! E. coli O157:H7 (Meridian Diagnostics, Inc., Cincinnati, Ohio) is a novel rapid (10-min) test for the presence of Escherichia coli O157:H7 in stools. The test may be performed either directly on stool specimens or on an overnight broth culture of stool. In a multicenter prospective study, 14 of 14 specimens positive by culture for E. coli O157:H7 were positive by the ImmunoCard STAT! O157:H7 test, and there were no false positives from 263 culture-negative specimens. In a retrospective study, the test was positive in 339 (81%) of 417 stored culture-positive specimens and the specificity was 95% (98 of 103 specimens). No false positives were associated with alternate stool pathogens. The ImmunoCard STAT! O157:H7 test has high sensitivity and specificity.  相似文献   

2.
We evaluated the Meridian IC-STAT direct fecal and broth culture antigen detection methods with samples from children infected with Escherichia coli O157:H7 and correlated the antigen detection results with the culture results. Stools of 16 children who had recently had stool cultures positive for this pathogen (population A) and 102 children with diarrhea of unknown cause (population B) were tested with the IC-STAT device (direct testing). Fecal broth cultures were also tested with this device (broth testing). The results were correlated to a standard of the combined yield from direct culture of stools on sorbitol-MacConkey (SMAC) agar and culture of broth on SMAC agar. Eleven (69%) of the population A stool specimens yielded E. coli O157:H7 when plated directly on SMAC agar. Two more specimens yielded this pathogen when the broth culture was similarly plated. Of these 13 stool specimens, 8 and 13 were positive by direct and broth testing (respective sensitivities, 62 and 100%). Compared to the sensitivity of a simultaneously performed SMAC agar culture, the sensitivity of direct testing was 73%. Three (3%) of the population B stool specimens contained E. coli O157:H7 on SMAC agar culture; one and three of these stool specimens were positive by direct and broth testing, respectively. The direct and broth IC-STAT tests were 100% specific with samples from children from population B. Direct IC-STAT testing of stools is rapid, easily performed, and specific but is insufficiently sensitive to exclude the possibility of infection with E. coli O157:H7. Performing the IC-STAT test with a broth culture increases its sensitivity. However, attempts to recover E. coli O157:H7 by culture should not be abandoned but, rather, should be increased when the IC-STAT test result is positive.  相似文献   

3.
A method for the rapid detection of verotoxin-producing Escherichia coli in stool samples by PCR was evaluated. Verotoxin-1 and verotoxin-2 genes in DNA extracted directly from stool samples were amplified with oligonucleotide primers. Stools spiked with control organisms, E. coli C600 (H19B) (verotoxin-1) or E. coli C600 (933W) (verotoxin-2), demonstrated that verotoxin-1-containing organisms could be detected at 10(2) CFU per 0.1 g of stool and verotoxin-2-containing organisms could be detected at 10(7) CFU per 0.1 g of stool. Testing of stool samples from patients with diarrhea showed a high concordance between PCR positivity and the presence of verotoxin-producing E. coli, determined by isolation of serotype O157:H7 on sorbitol-MacConkey medium (34 of 35 stool samples) or by colony blots with gene probes (19 of 21 stool samples). Conversely, only 1 of 20 (5.0%) stool samples that were O157:H7 culture negative and colony blot negative and that contained free verotoxin only was positive by PCR. As well, only 4 of 145 (2.8%) stool samples that were negative for serotype O157:H7 or free verotoxin were PCR positive. PCR of DNA extracted directly from stool samples provides a rapid method for the detection of stool samples containing verotoxin-producing E. coli compared with colony blot testing.  相似文献   

4.
An evaluation of the sensitivities of three DNA extraction methods, i.e., FTA filter paper, a QIAamp stool mini kit, and a conventional phenol-chloroform method, by using specimens with known concentrations of Enterocytozoon bieneusi spores was performed. FTA filter paper and the QIAamp stool mini kit were the most sensitive methods, which could detect E. bieneusi in specimens with a concentration of 800 spores/ml. We also compared five previously described PCR methods that use five different primer pairs for the detection of E. bieneusi and showed that MSP3-MSP4B and EBIEF1-EBIER1 were the most sensitive primers. Although both sets of primers showed the same sensitivity, using the MSP3-MSP4B primers can directly provide genotypic information by sequencing. A blinded diagnostic test to compare PCR and light microscopy methods for the detection of E. bieneusi in stool specimens was also conducted. The use of FTA filter paper for DNA extraction together with the PCR method using the primer pair MSP3-MSP4B showed 100% sensitivity and 100% specificity for the detection of E. bieneusi in stool specimens, while the light microscopy method gave a sensitivity of 86.7% and a specificity of 100%.  相似文献   

5.
Escherichia coli serotype O157:H7 is a recently recognized human pathogen associated with hemorrhagic colitis. Unlike most E. coli strains, E. coli O157:H7 does not ferment sorbitol. Therefore, the efficacy of MacConkey agar containing sorbitol (SMAC medium) instead of lactose as a differential medium for the detection of E. coli O157:H7 in stool cultures was determined in comparison with MacConkey agar. The relative frequency of non-sorbitol-fermenting (NSF) organisms other than E. coli O157:H7 in feces was low at 10 to 20% (95% confidence limits), and NSF organisms also occurred mostly in small numbers. In a field trial involving over 1,000 diarrheal stools, E. coli O157:H7 was isolated from 18 stools, all of which were from patients with bloody diarrhea. In every instance, the growth of E. coli O157:H7 on SMAC medium was heavy and occurred in almost pure culture as colorless NSF colonies in contrast to fecal flora, which are mostly sorbitol fermenting and hence appear pink on this medium, whereas on MacConkey agar cultures, the growth of E. coli O157:H7 was indistinguishable from fecal flora. SMAC medium permitted ready recognition of E. coli O157:H7 in stool cultures. Detection of E. coli O157:H7 on SMAC medium had a sensitivity of 100%, a specificity of 85%, and an accuracy of 86%. SMAC medium stool culture is a simple, inexpensive, rapid, and reliable means of detecting E. coli O157:H7, and we recommend routine use of SMAC medium especially for culturing bloody stools.  相似文献   

6.
An enzyme-linked immunosorbent assay for the detection of Shiga toxins (Premier EHEC assay; Meridian Diagnostics, Inc.) was compared to conventional sorbitol-MacConkey culture for the recovery of enterohemorrhagic Escherichia coli. A total of 74 enteric pathogens, including 8 E. coli O157:H7 isolates, were recovered from 974 stool specimens. Two of these specimens were not tested by Premier assaying due to insufficient sample and are not considered in the data analysis. The Premier EHEC assay detected the 6 evaluable specimens which were culture positive for E. coli O157:H7 and identified an additional 10 specimens as containing Shiga toxin. Seven isolates were recovered from these 10 specimens by an immunoblot assay and were confirmed as toxin producers by a cytotoxin assay. Of these seven, four isolates were serotype O157:H7, one was O26:NM, one was O6:H-, and one was O untypeable:H untypeable. Three specimens contained Shiga toxin by both EHEC immunoassaying and cytotoxin testing; however, no cytotoxin-producing E. coli could be recovered. The sorbitol-MacConkey method had a sensitivity and a specificity of 60 and 100%, respectively, while the Premier EHEC assay had a sensitivity and a specificity of 100 and 99.7%, respectively, for E. coli O157:H7 only. The Premier EHEC assay also detected an additional 20% Shiga toxin-producing E. coli (STEC) that were non-O157:H7. Thus, the Premier EHEC assay is a sensitive and specific method for the detection of all STEC isolates. Routine use would improve the detection of E. coli O157:H7 and allow for determination of the true incidence of STEC other than O157:H7. The presence of blood in the stool and/or the ages of the patients were poor predictors of the presence of STEC. Criteria need to be determined which would allow for the cost-effective incorporation of this assay into the routine screen for enteric pathogens in high-risk individuals, especially children.  相似文献   

7.
Objective: To determine the incidence of infection with Escherichia coli O157:H7 in a tertiary referral center in Chicago, where a similar study had been performed in 1984, to evaluate cases of disease reported to the Illinois Department of Public Health (IDPH) in 1993, and to determine laboratory practices used to detect this infection throughout the state.
Methods: During a 6-month period in 1993, all stool specimens at Rush-Presbyterian-St Luke's Medical Center (RPSLMC) were tested for E. coli O157:H7. Reports of diagnosed E. coli O157:H7 cases investigated by IDPH were also reviewed. A survey of 73 hospitals in the Chicago area was performed to determine routine culturing practices, specifically, the selection of stool specimens for evaluation for this pathogen.
Results: In the RPSLMC survey, two cases were identified among 1985 samples (incidence 0.1%), similar to the 0.08% incidence detected in a similar study conducted at the same institution in 1984. Through passive surveillance, the IDPH received 44 reports of E. coli O157:H7 in 1993. The hospital survey revealed that, in the seven labs testing all stool specimens for E. coli O157:H7, an incidence of 16/8137 specimens (0.2%) was determined.
Conclusions: These data suggest that sporadic E. coli O157:H7 remains uncommon in Illinois and that the incidence may not have changed over a 9-year period. The low yield and substantial cost of culturing all stools suggest that only specimens from patients with bloody diarrhea should be evaluated routinely in areas of low endemicity.  相似文献   

8.
During a 10-week period in the summer of 1990, an epidemiologic investigation of the prevalence of verotoxin (VT)-producing Escherichia coli infection was conducted in Calgary, Alberta, Canada. Consecutive stool specimens (n = 3,577) were cultured for E. coli O157:H7, and fecal filtrates were tested for free VTs (FVTs). E. coli O157:H7 was recovered from 22 specimens (0.6%), but VT was detected in 74 specimens (2.1%). Sixty-nine stool specimens positive for FVTs or E. coli O157:H7 were probed for VT genes by colony blot hybridization; 22 of 38 VT gene probe-positive isolates were non-O157:H7 E. coli organisms. Fourteen of 22 strains could not be induced to produce VT in vitro, despite the presence of FVTs in the stool sample, positivity on colony blot hybridization, positive PCR probes with the primers described by Pollard et al. (D. R. Pollard, W. M. Johnson, H. Lior, S. D. Tyler, and K. R. Rozee, J. Clin. Microbiol. 28:540-545, 1990) or Gannon et al. (V. P. Gannon, R. K. King, J. Y. Kim, and E. J. Golsteyn-Thomas, Appl. Environ. Microbiol. 58:3809-3815, 1992) (but not those described by Karch and Meyer [H. Karch and T. Meyer, J. Clin. Microbiol. 27:2751-2757, 1989]), and positive Southern blot analysis of isolates in 10 of 14 strains. The patient survey questionnaire showed that E. coli O157:H7 infection was associated with bloody diarrhea of short duration, whereas infection with other serotypes or persistence of FVT only was associated with longer-duration nonbloody diarrheal illness.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

9.
The plasmid-borne sfpA gene encodes the pilin subunit in sorbitol-fermenting (SF) enterohemorrhagic Escherichia coli (EHEC) O157:H-. We investigated the distribution of sfpA among 600 E. coli isolates comprising the complete E. coli standard reference (ECOR) and diarrheagenic E. coli (DEC) strain collections and clinical isolates associated with enteric disease. sfpA was detected in DEC3F SF EHEC O157:H- strain 493/89, each of 107 SF EHEC O157:H- clinical isolates, and 14 Shiga toxin-negative SF E. coli O157:H- strains which contained eae, which encodes gamma-intimin, and fliC, which encodes the H7 antigen. sfpA was absent from all other strains, including the ECOR strain collection, all non-SF EHEC O157:H7 strains, and all E. coli O55:H7 strains (E. coli O55:H7 is the postulated ancestor of Shiga toxin-producing E. coli [STEC] O157). These results suggest that there was a single acquisition of the sfpA gene in the nonmotile SF E. coli O157 branch, presumably after the eae-encoding pathogenicity island (the locus of enterocyte effacement) was acquired and motility was lost. We then applied the sfpA PCR in combination with rfbO157, stx, and eae PCRs to screen 636 stool samples from patients with diarrhea or hemolytic-uremic syndrome for SF STEC O157:H-. In 27 cases, the simultaneous presence of the sfpA, eae, and rfbO157 amplicons indicated the presence of SF E. coli O157:H- strains, and the result was subsequently confirmed by isolation. All but two of these strains possessed stx2. None of the other stool samples was positive by the sfpA PCR; 59 of these stool samples contained EHEC O157:H7. The sfpA gene can be recommended as a target for screening for SF E. coli O157:H-.  相似文献   

10.
A direct fecal Shiga-like toxin assay (DSLTA) was used to prospectively screen 9,449 unselected stool samples, received at the British Columbia Provincial Health Laboratories and the Metropolitan Laboratories of Vancouver, for Shiga-like toxin I and Shiga-like toxin II. The results were compared with results of routine stool culture on sorbitol-MacConkey agar (SMAC) for Escherichia coli O157:H7. Of 80 specimens positive by either method, 59 (74%) and 74 (93%) were positive by SMAC and DSLTA, respectively; 53 (66%) were positive by both methods, 21 (26%) were positive by DSLTA only, and 6 (7%) were positive by SMAC only. On further screening, Shiga-like toxin-producing E. coli were detected in 8 (38%) of the 21 stools positive by DSLTA only, including serotypes O157:H7 (1 stool), O26:K60 (5 stools), O128:K67 (1 stool), and O103:H2 (1 stool). For the remaining 13 stools in which no SLTEC was found but DSLTA was positive, clinical information revealed that 11 of 12 patients had diarrheal illnesses, and 4 of these 11 had bloody diarrhea or hemolytic-uremic syndrome. Stools positive only by SMAC were collected earlier in the illness than stools positive by DSLTA, suggesting that free fecal toxin levels may be too low to detect at this time. Overall we found that DSLTA detected 19% more positive specimens than SMAC and that Shiga-like toxin-producing E. coli serotypes other than E. coli O157:H7 are causing disease in the province of British Columbia, Canada.  相似文献   

11.
Among bovine fecal and recto-anal mucosal swab samples cultured in our laboratory for Escherichia coli O157:H7, we frequently isolated E. coli organisms that were phenotypically similar to the O157:H7 serotype as non-sorbitol fermenting and negative for beta-glucuronidase activity but serotyped O nontypeable:H25 (ONT:H25). This study determined the prevalence and virulence properties of the E. coli ONT:H25 isolates. Among dairy and feedlot cattle (n = 170) sampled in Washington, Idaho, and Alberta, Canada, the percentage of animals culture positive for E. coli ONT:H25 ranged from 7.5% to 22.5%, compared to the prevalence of E. coli O157:H7 that ranged from 0% to 15%. A longitudinal 8-month study of dairy heifers (n = 40) showed that 0 to 15% of the heifers were culture positive for E. coli O157:H7, while 15 to 22.5% of the animals were culture positive for E. coli ONT:H25. As determined by a multiplex PCR, the E. coli ONT:H25 isolates carried a combination of virulence genes characteristic of the enterohemorrhagic E. coli, including intimin, translocated intimin receptor, Stx2, and hemolysin (eae-beta, tir, stx(2vh-a), and hly). E. coli ONT:H25 isolates from diverse geographic locations and over time were fingerprinted by separating XbaI-restricted chromosomal DNA by pulsed-field gel electrophoresis (PFGE) separation. Two strains of E. coli ONT:H25 were highly similar by PFGE pattern. Experimental inoculation of cattle showed that E. coli ONT:H25, like E. coli O157:H7, colonized the bovine recto-anal junction mucosa for more than 4 weeks following a single rectal application of bacteria.  相似文献   

12.
The isolation and characterization of Escherichia coli O157:H7 and non-O157 Shiga toxin-producing E. coli (STEC) strains from sheep are described. One flock was investigated for E. coli O157:H7 over a 16-month period that spanned two summer and two autumn seasons. Variation in the occurrence of E. coli O157:H7-positive sheep was observed, with animals being culture positive only in the summer months but not in the spring, autumn, or winter. E. coli O157:H7 isolates were distinguished by pulsed-field gel electrophoresis (PFGE) of chromosomal DNA and toxin gene restriction fragment length polymorphism (RFLP) analysis. Ten PFGE patterns and five RFLP patterns, identified among the isolates, showed that multiple E. coli O157:H7 strains were isolated from one flock, that a single animal simultaneously shed multiple E. coli O157:H7 strains, and that the strains shed by individuals changed over time. E. coli O157:H7 was isolated only by selective enrichment culture off 10 g of ovine feces. In contrast, strains of eight STEC serotypes other than O157:H7 were cultured from feces of sheep from a separate flock without enrichment. The predominant non-O157 STEC serotype found was O91:NM (NM indicates nonmotile), and others included O128:NM, O88:NM, O6:H49, and O5:NM. Irrespective of serotype, 98% of the ovine STEC isolates possessed various combinations of the virulence-associated genes for Shiga toxin(s) and the attaching-and-effacing lesion (stx1, stx2, and eae), suggesting their potential for human pathogenicity. The most common toxin-eae genotype was positive for stx1, stx2, and eae. A Vero cell cytotoxicity assay demonstrated that 90% of the representative STEC isolates tested expressed the toxin gene. The report demonstrates that sheep transiently shed a variety of STEC strains, including E. coli O157:H7, that have potential as human pathogens.  相似文献   

13.
The Association of State and Territorial Public Health Laboratory Directors has recommended that clinical laboratories screen at least all bloody stools for Escherichia coli O157:H7. We contacted the microbiology supervisors of 230 randomly selected clinical laboratories in the United States and administered a standardized questionnaire regarding stool culture practices. Of the 129 laboratories that performed stool cultures, only 70 (54%) reported screening either all stools or all bloody stools submitted for culture for E. coli O157:H7.  相似文献   

14.
An enzyme-linked immunosorbent assay (ELISA) produced by LMD Laboratories, Inc., Carlsbad, Calif., was compared with culture for the detection of Escherichia coli O157. Nine of 185 stool specimens evaluated had positive results by the LMD E. coli O157 ELISA and grew E. coli O157 on culture; 174 had negative by LMD E. coli O157 ELISA results and did not grow E. coli O157 on culture. Of 174 specimens negative by LMD E. coli O157 ELISA, 117 specimens grew other enteric pathogens: Campylobacter spp. (46 isolates), Salmonella spp. (43 isolates), Yersinia spp. (20 isolates), and Shigella spp. (8 isolates). There were two indeterminant results by the LMD E. coli O157 ELISA. One stool specimen did not grow other enteric pathogens on culture, and one grew a Campylobacter sp. on culture. Both had negative LMD E. coli O157 ELISA results upon repeat testing. The LMD E. coli O157 ELISA is an accurate, easy-to-read screening method for the detection of E. coli O157 in fecal specimens.  相似文献   

15.
The present study was conducted to compare two stool antigen detection kits with PCR for the diagnosis of Entamoeba histolytica infections by using fecal specimens submitted to the Department of Microbiology at St. Vincent's Hospital, Sydney, and the Institute of Medical and Veterinary Science, Adelaide, Australia. A total of 279 stool samples containing the E complex (E. histolytica, Entamoeba dispar, and Entamoeba moshkovskii) were included in this study. The stool specimens were tested by using two commercially produced enzyme immunoassays (the Entamoeba CELISA PATH and TechLab E. histolytica II kits) to detect antigens of E. histolytica. DNA was extracted from all of the samples with a Qiagen DNA stool mini kit (Qiagen, Hilden, Germany), and a PCR targeting the small-subunit ribosomal DNA was performed on all of the samples. When PCR was used as a reference standard, the CELISA PATH kit showed 28% sensitivity and 100% specificity. The TechLab ELISA (enzyme-linked immunosorbent assay) kit did not prove to be useful in detecting E. histolytica, as it failed to identify any of the E. histolytica samples which were positive by PCR. With the TechLab kit, cross-reactivity was observed for three specimens, one of which was positive for both E. dispar and E. moshkovskii while the other two samples contained E. moshkovskii. Quantitative assessment of the PCR and ELISA results obtained showed that the ELISA kits were 1,000 to 10,000 times less sensitive, and our results show that the CELISA PATH kit and the TechLab ELISA are not useful for the detection of E. histolytica in stool samples from patients in geographical regions where this parasite is not endemic.  相似文献   

16.
Shiga toxin-producing Escherichia coli (STEC) in northern Alberta was detected using two enzyme immunoassays and an in-house real-time PCR. Of 2,328 stool samples, 8 were positive for O157:H7 STEC and 13 were positive for non-O157 STEC. No significant gender (P = 0.17) or age (P = 0.81) differences between groups were seen. Most positive diarrheal stool samples were nonbloody.  相似文献   

17.
多重实时荧光定量PCR检测肠出血性大肠杆菌O157:H7   总被引:1,自引:0,他引:1  
目的 利用多重荧光定量PCR技术,建立一种快速、准确、特异检测肠出血性大肠杆菌O157:H7的定量方法.方法 选取肠出血性大肠杆菌O157:H7编码脂多糖基因(rfbE)和编码鞭毛抗原基因(fliC)作为检测的靶基因,设计引物和TaqMan-MGB探针,探针的5'端分别用FAM和HEX进行荧光标记,3'端标记MGB.优化PCR扩增体系,对多重实时荧光定量PCR方法的特异性、灵敏度、重复性评价,同时进行一定数量临床样本鉴定,与常规方法进行比较.结果 本研究所建立的多重实时荧光定量PCR方法可准确、特异地检测和鉴定肠出血性大肠杆菌O157:H7,能够有效甄别肠出血性大肠杆菌O157:H7与非H7菌株,其他菌株均无阳性结果;该方法的灵敏度可达到10 CFU/ml;定量检测的批间和批内变异系数均小于5%;对66例临床样本进行评价,结果显示15例肠出血性大肠杆菌O157:H7阳性,2例为肠出血性大肠杆菌O157:非H7阳性,其中16例与常规培养法结果符合,符合率达到98.49%.结论 本研究建立的检测肠出血性大肠杆菌O157:H7多重实时荧光定量PCR方法快速,结果准确、可靠,操作简便,为肠出血性大肠杆菌O157:H7的临床诊断、现场流行病学调查和食品安全监测提供了新的鉴定方法.  相似文献   

18.
The largest reported outbreak of waterborne Escherichia coli O157:H7 in the United States occurred in upstate New York following a county fair in August 1999. Culture methods were used to isolate E. coli O157:H7 from specimens from 128 of 775 patients with suspected infections. Campylobacter jejuni was also isolated from stools of 44 persons who developed diarrheal illness after attending this fair. There was one case of a confirmed coinfection with E. coli O157:H7 and C. jejuni. Molecular detection of stx(1) and stx(2) Shiga toxin genes, immunomagnetic separation (IMS), and selective culture enrichment were utilized to detect and isolate E. coli O157:H7 from an unchlorinated well and its distribution points, a dry well, and a nearby septic tank. PCR for stx(1) and stx(2) was shown to provide a useful screen for toxin-producing E. coli O157:H7, and IMS subculture improved recovery. Pulsed-field gel electrophoresis (PFGE) was used to compare patient and environmental E. coli O157:H7 isolates. Among patient isolates, 117 of 128 (91.5%) were type 1 or 1a (three or fewer bands different). Among the water distribution system isolates, 13 of 19 (68%) were type 1 or 1a. Additionally, PFGE of C. jejuni isolates revealed that 29 of 35 (83%) had indistinguishable PFGE patterns. The PFGE results implicated the water distribution system as the main source of the E. coli O157:H7 outbreak. This investigation demonstrates the potential for outbreaks involving more than one pathogen and the importance of analyzing isolates from multiple patients and environmental samples to develop a better understanding of bacterial transmission during an outbreak.  相似文献   

19.
We examined 1,266 fecal specimens from healthy cattle during the investigations of two sporadic cases of hemolytic uremic syndrome associated with raw milk consumption and an outbreak of gastroenteritis and hemolytic uremic syndrome caused by Escherichia coli serotype O157:H7. We collected specimens from heifers, calves, and adult cows on 22 farms, in a stockyard, and in a packing house. We also collected 3 raw hamburger specimens from a restaurant and 23 raw milk samples from two farms. All specimens were examined for E. coli O157:H7 by using sorbitol-MacConkey agar, H immobilization, O157 agglutination, and tissue culture cytotoxicity. E. coli O157:H7 was isolated from 16 heifers or calves and 1 adult cow on 22 farms, 1 stockyard calf, 2 beef specimens, and 1 raw milk sample. Selected fecal specimens were also examined for the presence of other Shiga-like-toxin-producing E. coli (SLTEC) by testing polymyxin B extracts of colony sweeps and then testing individual colonies for toxin production. SLTEC other than O157 was isolated from 8 of 10 farms investigated and from the stockyard; 8% of adult cows and 19% of heifers and calves were positive for SLTEC. Several animals were positive for SLTEC by colony sweep only. This investigation demonstrates that dairy cattle are a reservoir of E. coli O157:H7 and other SLTEC.  相似文献   

20.
Objective: To reassess the occurrence of verocytotoxin-producing Escherichia coli (VTEC) in French hemolytic uremic syndrome (HUS) patients.
Method: From March 1991 to January 1995, direct detection of verotoxin genes (VT) by the polymerase chain reaction (PCR) was performed on stool samples from 169 patients suffering from HUS.
Results: Fifty-one were PCR positive (30.1%); one was positive for the VT1 gene and the others for the VT2 gene. VTEC was isolated from only 32 of the 51 PCR-positive samples. E. coli O157:H7 was isolated from five patients. E. coli O111 was isolated from seven patients during an outbreak of HUS. Among the other VT2 E. coli strains, only four were serotypable. Of the 51 PCR-positive stools, 19 were culture negative for VTEC.
Conclusions: This study provides evidence that in France E. coli O157 and other VTEC serotypes are involved in HUS.  相似文献   