首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PURPOSE: In this study we assessed the relative yield of 10 core biopsy, and the whole range of alternative 8 and 6 core biopsy protocols over that of the classic sextant biopsy protocol. We determined the optimum number of cores per biopsy according to prostate volume in patients who experienced prostate biopsy for the first time. MATERIALS AND METHODS: A total of 503 men with the indications of abnormal digital rectal examination and/or serum prostate specific antigen greater than 2.5 ng/ml were included in the study. All patients underwent a 10 core biopsy protocol with an additional 1 core from each suspicious area detected by transrectal ultrasound. Prostate volume was divided into quartiles, namely 14.9 to 35, 35.1 to 50, 50.1 to 65 and 65.1 to 150 cc. The optimum number of biopsy cores was determined in patients with different prostate volumes. RESULTS: Median age was 63 years and prostate specific antigen was 7.4 ng/ml in the whole group. Of 503 patients 159 (31.6%) were positive for prostate cancer. Cancer detection rates decreased significantly from 49.6% to 20.8% as prostate volume increased in preset quartiles. Lesion biopsies revealed the lowest unique cancer detection rates for all prostate volume quartiles (0% to 3%). There was an obvious positive trend in cancer detection rates in favor of the 10 core biopsy protocol over sextant biopsies in all patient groups. Classic sextant biopsy protocol proved to be inadequate for all prostate volumes. Among sextant biopsy protocols laterally placed cores including the apex, lateral mid gland and lateral base had the best cancer detection rates (81% to 95%). The 8 core biopsy scheme consisting of the apex, mid gland, lateral mid gland and lateral base resulted in an only 1% lower detection rate (97%) than the 10 core biopsy protocol in the lowest quartile. The yield of the 10 core biopsy protocol in patients with a prostate volume of between 35.1 and 150 cc outscored that of the optimal 8 core biopsy scheme including the apex, base, lateral mid gland and lateral base with 3% to 8% differences in the cancer detection rate. CONCLUSIONS: The 10 core biopsy protocol must be used in all group of patients except patients with a prostate volume of 14.9 to 35 cc. In patients with a prostate volume of 14.9 to 35 cc the 8 core biopsy protocol consisting of the apex, mid gland, lateral mid gland and lateral base can be used since it revealed results similar to those of the 10 core biopsy protocol. The classic sextant biopsy protocol seemed inadequate for all prostate volumes. Patients with a larger prostate had lower cancer detection rates. Transrectal ultrasound directed lesion biopsies may be omitted when using 10 core biopsy protocols since the yield of these biopsies was less than 2%.  相似文献   

2.
PURPOSE: Research to improve prostate cancer detection with transrectal ultrasound-guided prostate biopsies has focused on increasing the number of cores and the directing of biopsies laterally. In this study, we describe our experience with the addition of anterior apical biopsies. MATERIALS AND METHODS: A total of 164 consecutive patients with an increased or increasing prostate-specific antigen and/or abnormal digital rectal examination underwent transrectal ultrasound and systematic biopsy. We performed our standard laterally directed sextant biopsies plus additional mid parasagittal plane biopsies at the base and mid-gland, and an anteriorly directed biopsy at the apex. Site-specific detection and tumor characteristics are reported. RESULTS: Prostate cancer was detected in 71 patients (43.3%). The most commonly unique site was the anterior apex. Excluding these biopsies would have missed 17% of the cancers detected. The cancers limited to the anterior apex had tumor characteristics similar to all other cancers detected. CONCLUSION: In our experience, the anterior apical biopsies increase the detection of prostate cancer on transrectal ultrasound-guided biopsies. Further study on incorporating this site into the biopsy scheme is indicated.  相似文献   

3.
不同前列腺穿刺活检方案检出前列腺癌的比较   总被引:4,自引:0,他引:4  
目的探讨理想的前列腺穿刺活检方案。方法临床表现怀疑前列腺癌患者214例,其中前列腺特异抗原〉4.0ng/ml 203例。均行13针前列腺穿刺活检术。年龄50~90岁,平均70岁;PSA水平0.8~112.3ng/ml,平均18.7ng/ml;前列腺体积12.3~182.5ml,平均61.3ml;直肠指诊阴性173例,阳性者41例。依穿刺结果,对比分析13针中6、8、10和13针穿刺阳性率。结果13针穿刺阳性率为36.0%(77/214)。在各种穿刺点组合中包含前列腺尖部、中部、底部、外侧中部、外侧底部的10针法能发现全部前列腺癌阳性病例的97.4%,与13针穿刺结果的差异无统计学意义(P=0.5)。结论对于初次前列腺活检的病例,包含尖部、中部、底部、外侧中部、外侧底部的10针法是较为合理的选择。  相似文献   

4.
PURPOSE: We examine the potential impact of extended systematic biopsy schemes in patients with a prior negative prostate biopsy. MATERIALS AND METHODS: Between January 1999 and March 2001, 185 patients with a prior negative prostate needle biopsy underwent repeat biopsy. Systematic 10 core biopsies (sextant, lateral mid gland and lateral base) were performed in all patients. A subset of 111 patients underwent 6 additional biopsies directed anteriorly. All biopsy results were reviewed by a single pathologist. The overall and unique cancer detection rates were calculated for each biopsy site. McNemar's test was then used to compare the yield of various simulated biopsy schemes to define the optimal biopsy regimen. RESULTS: Overall, 67 of 185 patients (36%) were found to have cancer on repeat biopsy. The highest detection rate was found for the apex, lateral base and lateral mid sites. The mid lobar base site consistently yielded the lowest detection rate. These results were mirrored in the unique cancer detection rate calculations. The traditional sextant scheme detected only 73% of tumors. Using a lateral sextant scheme (apex, lateral mid gland and lateral base), the detection rate increased to 85% (p = 0.15). An 8 core biopsy scheme (apex, mid gland, lateral mid gland and lateral base) increased the detection rate to 95%. However, there was no significant increase in cancer detection rate when the 8 core scheme was compared to the 10 core scheme. The 6 anteriorly directed biopsies uniquely detected only 2 cancers. CONCLUSIONS: We recommend that patients with a prior negative prostate biopsy who are undergoing repeat biopsy receive at least an 8 core biopsy scheme weighted toward the lateral aspect of the prostate.  相似文献   

5.
B超引导10点前列腺穿刺法诊断前列腺癌的结果分析   总被引:2,自引:0,他引:2  
目的探讨经直肠超声引导下10点法前列腺穿刺活检中前列腺癌阳性结果的分布情况。方法本组473例均因PSA>4ng/ml而进行经直肠超声引导下10点法宝前列腺穿刺活检,穿刺点为在标准的系统6点(前列腺旁正中线矢状切面尖部、中部、底部)的基础上,两外侧各增加2针(外侧周缘中部、底部)。本组患者年龄为41~85岁,平均65岁;PSA水平4.1~444ng/ml,平均15.05ng/ml;前列腺体积8.0~160.0ml,平均42.17ml。对穿刺各针的阳性率及各区域独立出现的阳性率进行分析。结果穿刺总阳性率为26.6%(126/473)。前列腺各穿刺部位的阳性率为:外侧底部23.7%(112/473)、外侧中部20.7%(98/473)、底部19.5%(92/473)、中部18.4%(87/473)、尖部23.9%(113/473)。只有该区域出现阳性的分布情况:外侧底部8.7%(11/126)、外侧中部5.6%(7/126)、底部2.4%(3/126)、中部3.2%(4/126)、尖部7.1%(9/126)。各穿刺部位的阳性率具有统计学差异(P<0.01)。结论经直肠超声引导下经直肠前列腺10点法穿刺活检术可明显提高前列腺癌的临床检出率。其前列腺的尖部、外侧底部和外侧中部的穿刺阳性率要比其他部位高。  相似文献   

6.
Urologists routinely use the systematic sextant needle biopsy technique to detect prostate cancer. However, recent evidence suggests that this technique has a significant sampling error and data based upon whole-mounted step-sectioned radical prostatectomy specimens using a three-dimensional computer-assisted prostate biopsy simulator suggests that an increased detection rate is possible using laterally placed biopsies. The simulated 10-core biopsy pattern (traditional sextant biopsy cores and four laterally placed biopsies in the right and left apex and mid portion of the prostate gland) was shown to be superior to the traditional sextant biopsy. The objective of this pilot study was to confirm the higher prostate cancer detection rate obtained using the 10-core biopsy pattern in patients. We reviewed data on 35 consecutive patients with a pathologic diagnosis of prostate cancer biopsied by a single urologist using the 10-core biopsy pattern. The frequency of positive biopsy was determined for each core. Additionally, the sextant and 10-core prostate biopsy patterns were compared with respect to prostate cancer detection rate. Of the 35 patients diagnosed with prostate cancer, 54.3%(19/35) were diagnosed by the sextant biopsy only. The 10-core pattern resulted in an additional 45.7%(16/35) of patients being diagnosed solely with the laterally placed biopsies. The laterally placed biopsies had the highest frequency of positive biopsies when compared to the sextant cores. In conclusion, biopsy protocols that use laterally placed biopsies based upon a five region anatomical model are superior to the routinely used sextant prostate biopsy pattern. Prostate Cancer and Prostatic Diseases (2000) 3, 43-46  相似文献   

7.
PURPOSE: The performance characteristics of percent free (f) prostate specific antigen (PSA) for differentiating between benign prostatic hyperplasia and prostate cancer were originally established using primarily sextant biopsy. We determined whether the addition of 6 laterally directed cores to the traditional sextant prostate biopsy affects the performance of percent fPSA. MATERIALS AND METHODS: We retrospectively evaluated a cohort of 350 consecutive biopsies in men with negative digital rectal examinations and PSA between 4 and 10 ng/ml who underwent systematic 12 core biopsy (S12C) biopsy at Scott Department of Urology between March 1999 and January 2003. The effects of 6 additional, laterally directed biopsies on the sensitivity, specificity and area under the ROC curve for percent fPSA was evaluated in the 277 men in whom percent fPSA was measured. RESULTS: Cancers detected exclusively in the 6 laterally directed cores were associated with percent fPSA values similar to those in patients with a benign S12C biopsy. This resulted in a modest and yet predictable decrease in the sensitivity of percent fPSA at each biopsy threshold value without affecting specificity. There was a nonstatistically significant decrease in the area under the ROC curve with the addition of 6 laterally directed cores to sextant biopsy (medial sextant cores 0.66 vs S12C 0.60). CONCLUSIONS: The 12 core biopsy strategies have a higher cancer detection rate than sextant biopsies and they are gaining widespread acceptance. The addition of 6 laterally directed cores to traditional sextant biopsy may result in a modest decrease in the sensitivity of percent fPSA at each selected biopsy threshold without affecting specificity.  相似文献   

8.
OBJECTIVE: To review and critically analyse all the recent literature on the detection and characterisation of prostate cancer by means of extended and saturation protocols. METHODS: A systematic review of the literature was performed by searching MedLine from January 1995 to April 2007. Electronic searches were limited to the English language, and the key words "prostate cancer," "diagnosis," "transrectal ultrasound (TRUS)," "prostate biopsy," and "prognosis" were used. RESULTS: The prostate biopsy technique has changed significantly since the original Hodge sextant biopsy protocol. Several types of local anaesthesia are now available, but periprostatic nerve block (PPNB) has proved to be the most effective method to reduce pain during TRUS biopsy. It remains controversial whether PPNB should be associated with other medications. The optimal extended protocol (sextant template with at least four additional cores) should include six standard sextant biopsies, with additional biopsies (up to 12 cores) taken more laterally (anterior horn) to the base and medially to the apex. Repeat biopsies should be based on saturation biopsies (number of cores >/= 20) and should include the transition zone, especially in a patient with an initial negative biopsy. As a means of increasing accuracy of prostatic biopsy and reducing unnecessary prostate biopsy, colour and power Doppler imaging, with or without contrast enhancement, and elastography now can be successfully adopted, but their routine use is still controversial. CONCLUSION: Extended and saturation biopsy schemes should be performed at first and repeat biopsy, respectively. The widespread use of local anaesthesia makes the procedures more comfortable.  相似文献   

9.
经直肠超声引导13点前列腺系统穿刺活检术160例报告   总被引:13,自引:3,他引:13  
目的 探讨经直肠超声引导 13点前列腺系统穿刺活检术诊断前列腺癌的临床价值。 方法 对 160例直肠指诊阳性和 (或 )PSA >4ng/ml的患者行经直肠超声引导 13点前列腺系统穿刺活检术。即在标准的经直肠超声引导 6点前列腺系统穿刺活检术同时 ,增加前列腺中间部位及前列腺两侧旁正中线远侧的穿刺点数 ,共穿刺活检 13点。将增加的 7点活检部位病理结果与标准的 6点前列腺系统穿刺活检术进行比较。 结果  160例患者中确诊为前列腺癌者 5 6例 ( 3 5 % )。 5 6例患者如按 6点穿刺方法 ,将有 12例患者漏诊 ,占 2 1%。 160例患者均未出现严重并发症。 结论 经直肠超声引导 13点前列腺系统穿刺活检术可明显提高前列腺癌的临床检出率  相似文献   

10.
Kawakami S  Okuno T  Yonese J  Igari T  Arai G  Fujii Y  Kageyama Y  Fukui I  Kihara K 《European urology》2007,51(3):675-82; discussion 682-3
OBJECTIVES: To explore an optimal combination of sampling sites to detect prostate cancer in a repeat biopsy setting. METHODS: A transrectal ultrasound-guided systematic three-dimensional 26-core biopsy (3D26PBx), a combination of transrectal 12 and transperineal 14 core biopsies, was performed in 235 Japanese men with prior negative biopsy. Using recursive partitioning, we evaluated cancer detection of all possible combinations of sampling sites and selected the combination that provides the highest cancer detection rate at a given number of biopsy cores. RESULTS: Prostate cancer was detected in 87 of the 235 (37%) men. The 3D26PBx improved cancer detection by 89% relative to the conventional transrectal sextant biopsy. Neither Gleason score nor percentage of Gleason 4/5 cancers differed between cancers with and without positive cores within the transrectal sextant-sampling sites. A three-dimensional combination of transrectal and transperineal approaches outperformed either transrectal or transperineal approach alone. Recursive partitioning revealed that a three-dimensional 16-core (transrectal eight cores plus transperineal eight cores) biopsy could detect all the cancers with the minimum number of cores. CONCLUSIONS: We propose a three-dimensional combination of transrectal eight cores taken from the far lateral peripheral zone and the parasagittal base, and transperineal eight cores taken from the anterior and posterior apex and the transition zone as an optimal set of sampling sites for repeat biopsy.  相似文献   

11.
OBJECTIVE: To assess cancer-detection rates in repeat 12-core biopsy protocols, as extended multicore prostate biopsy protocols have become standard when investigating men with a raised prostate-specific antigen (PSA) level, but repeat prostate biopsy protocols are still developing. PATIENTS AND METHODS: During a 4.5-year period, 241 of 590 patients with persistently high age-specific PSA levels of 2.6-10 ng/mL and an initial benign biopsy were invited for repeat transrectal ultrasonography-guided 12-core prostatic biopsy. The protocol for repeat biopsy was identical to the first biopsy, and included a periprostatic nerve block. The first six biopsies were obtained from the periphery of the gland directed more laterally at the base, mid-zone and apices. The remainder were parasagittal sextant biopsies. Pathological findings were analysed on an individual core basis. RESULTS: The mean age of the 241 men was 63.4 years; cancer was diagnosed in 40 (16.6%) on repeat biopsy. Men with cancer were older and had a higher median PSA level. The median Gleason score was 6, with a median of two cores positive for cancer. Maximum cancer detection rates were from peripheral apices (37.5%), basal biopsies had the lowest detection rates (23.8% and 16.3%), and parasagittal biopsies missed 35% of detected cancers. Patients with cancer also had significantly lower prostate volumes and higher PSA densities (both P < 0.001). CONCLUSION: A low cancer yield from both peripheral basal and parasagittal basal specimens on repeat biopsy indicates adequate sampling at initial biopsy. The maximum cancer yield in the peripheral mid-zones and apical zones suggests the necessity for concentrated sampling of these zones in repeat biopsy protocols.  相似文献   

12.
Extensive biopsy protocol improves the detection rate of prostate cancer   总被引:8,自引:0,他引:8  
PURPOSE: We evaluated improvement in the rate of prostate cancer detection when using an extensive biopsy protocol involving peripheral cores. MATERIALS AND METHODS: We prospectively evaluated 303 consecutive men who underwent transrectal ultrasound guided biopsy due to elevated prostate specific antigen (PSA) and/or abnormal digital rectal examination. Ten biopsies were performed, including at least 5 at the base and middle of each lobe. In addition to standard biopsy at a 45-degree angle, a more peripheral 30-degree angle biopsy was obtained. At the apex only 1 standard biopsy was done. However, when prostate volume was greater than 50 cm.3, an additional peripheral biopsy was obtained at the apex. RESULTS: The complication rate in this biopsy protocol was 1% (3 patients). Prostate cancer was detected in 118 of the 303 men (38. 9%). Overall this extensive protocol resulted in 6.6% improvement in the detection rate. Improvement was 6.5% in men with PSA 10 ng./ml. or less and 7% in those with PSA greater than 10 (not significant). CONCLUSIONS: Increasing the number of biopsy cores and improving prostate peripheral zone sampling resulted in a significant improvement in the detection of prostate cancer.  相似文献   

13.
Eskicorapci SY  Baydar DE  Akbal C  Sofikerim M  Günay M  Ekici S  Ozen H 《European urology》2004,45(4):444-8; discussion 448-9
OBJECTIVE: To evaluate the efficacy of TRUS guided 10-core biopsy strategy for Turkish patients who had biopsy of the prostate for the first time. METHODS: Between February 2001 and May 2003, 303 consecutive men with suspected prostate cancer were included in the study. Indications for TRUS guided prostate biopsy were: abnormal digital rectal examination and/or a serum PSA over 2.5 ng/ml. All of the patients underwent a 10-core biopsy protocol with additional core from the each suspicious area detected by TRUS. Besides the sextant technique, 4 more biopsies were obtained from the lateral peripheral zone. We aimed to analyze whether cancer detection improved with the extended versus the standard sextant biopsy in our series overall and in each subgroup. RESULTS: Of 303 patients 94 (31%) were positive for prostate cancer. Median age and PSA of prostate cancer patients were significantly higher than of the non-cancer patients. Besides prostate volumes of the cancer patients were significantly lower than of the non-cancer ones. The cancer detection rates were 31% (94/303) and 23.1% (70/303) for the 10-core biopsy strategy and sextant biopsy strategies, respectively. Thus the 10-core biopsy technique increased cancer detection rate by 25.5% (24/94) for the whole group of patients. A statistically significant number of additional cancers were detected with 10-core biopsy strategy for all the subgroups of the patients. Furthermore 10-core biopsy protocol detected more cancers (at least 6.4%) than all the probable different combinations of 8-core biopsy protocols. Among the 94 cancer patients, biopsy from a suspicious area revealed cancer in 31.9% of them; however, in all of these patients cancer was already present in the 10-core biopsy. On the other hand, lesion biopsies revealed 5.7% additional cancers if sextant technique was used. There were only 3 (0.9%) serious complications requiring hospitalization and all 3 were infections controlled by appropriate antibiotics. CONCLUSION: Adding 4 lateral peripheral biopsies to the conventional sextant biopsy (10-core biopsy strategy) technique has increased the cancer detection rate by 25.5% without significant morbidity and without increasing the number of insignificant cancers. 10-core biopsy protocol was superior to all probable 8-core biopsy protocols in our study group. Additional biopsies from suspicious areas detected by transrectal ultrasonography revealed no further benefit if 10-core technique was used. We therefore suggest that 10-core biopsy protocol should be the preferred strategy in early detection of prostate cancer.  相似文献   

14.
OBJECTIVE: To assess the cancer detection rate per individual core biopsy in a 12-core protocol and develop an optimal biopsy regimen for detecting early prostate cancer. PATIENTS AND METHODS: The study included 445 new patients who had a 12-core transrectal ultrasonography (TRUS)-guided prostatic biopsy over a 40-month period. The 12- core biopsy protocol included parasagittal sextant and six peripheral biopsies. The cancer detection rate per individual core was evaluated to give an optimal biopsy protocol. RESULTS: Prostate cancer was detected in 142 patients (31.9%). Parasagittal sextant biopsy would have failed to detect 40 (28.2%) of the cancers. Among the various possible biopsy protocols, the optimum 10-core biopsy strategy excluding the parasagittal mid-zone biopsies from the 12-core protocol achieved a cancer detection rate of 98.6%. CONCLUSION: The cancer detection rate increased from 71.8% for parasagittal sextant biopsies to 88.7% by adding peripheral basal biopsies (8-biopsy protocol); 98.6% of cancers in the series would have been detected with a 10-biopsy strategy omitting the parasagittal mid-zone biopsies. Thus we recommend a 10-core protocol incorporating six peripheral biopsies in patients with elevated age- specific prostate-specific antigen levels (2.6-10.0 ng/mL) for maximising cancer detection.  相似文献   

15.
Prostate biopsy (PBx) techniques have significantly changed since the original Hodge's ‘sextant scheme’, which should now be considered obsolete. The feasibility of carrying out a biopsy scheme with a high number of cores in an outpatient setting is a result of the great improvement and efficacy of local anesthesia. Peri‐prostatic nerve block with lidocaine injection should be considered the ‘gold standard’ because it provides the best pain relief to patients undergoing PBx. The optimal extended protocol should now include the sextant template with an additional 4–6 cores directed laterally (anterior horn) to the base and medially to the apex. Saturation biopsies (i.e. template with ≥20 cores, including transition zone) should be carried out only when biopsies are repeated in patients where there is a high suspicion of prostate cancer. Complementary imaging methods (such as color‐ and power‐Doppler imaging, with or without contrast enhancement, and elastography) could be used in order to increase the accuracy of biopsy and reduce the number of unnecessary procedures. Nevertheless, the routine use of these methods is still under evaluation.  相似文献   

16.
P G Borboroglu  C L Amling 《European urology》2001,39(6):648-53; discussion 654
OBJECTIVE: To investigate whether sextant location of positive prostate biopsy predicts the site of positive surgical margins (PSM) at the time of radical prostatectomy (RP) in patients with clinical stage T1c prostate cancer. METHODS: A retrospective query of the Center for Prostate Disease Research (CPDR) database at our institution identified 456 patients with clinical stage T1c prostate cancer who underwent standard sextant prostate biopsy prior to RP. Each biopsy was submitted separately for pathologic analysis according to sextant location. The sextant location of positive biopsies was compared to the sites of PSM after RP. RESULTS: PSM were found in 129 of 456 (28%) RP specimens. The incidence of PSM at the prostate apex in patients with a positive or negative apical sextant biopsy was similar (9 and 8% respectively, p>0.05). The incidence of PSM at the prostate base in patients with a positive or negative sextant biopsy of the prostate base was also the same (7% in both groups, p>0.05). As the number of positive biopsy cores on one side of the prostate increased (0, 1, 2, and 3) so did the chance of an ipsilateral PSM (5.4, 16.2, 35.7 and 45.0%, respectively; p<0.005). CONCLUSIONS: Positive sextant biopsy location (apex and base) does not correlate with site of PSM at RP. However, ipsilateral PSM are more likely as the number of positive sextant biopsies on that side increases. While pathologic processing of biopsy specimens according to longitudinal prostate location (base, mid and apex) is probably unnecessary, the number of positive biopsies on a given side may be useful preoperative information.  相似文献   

17.
We aimed to evaluate the cancer detection rates of 6-, 10-, 12-core biopsy regimens and the optimal biopsy protocol for prostate cancer diagnosis in patients with renal failure. A total of 122 consecutive patients with renal failure underwent biopsy with age-specific prostate-specific antigen (PSA) levels up to 20?ng/mL. The 12-core biopsy technique (sextant biopsy?+?lateral base, lateral mid-zone, lateral apex, bilaterally) performed to all patients. Pathology results were examined separately for each sextant, 10-core that exclude parasagittal mid-zones from 12-cores (10a), 10-core that exclude apex zones from 12-cores (10b) and 12-core biopsy regimens. Of 122 patients, 37 (30.3%) were positive for prostate cancer. The cancer detection rates for sextant, 10a, 10b and 12 cores were 17.2%, 29%, 23.7% and 30.7%, respectively. Biopsy techniques of 10a, 10b and 12 cores increased the cancer detection rates by 40%, 27.5% and 43.2% among the sextant technique, respectively. Biopsy techniques of 10a and 12 cores increased the cancer detection rates by 17.1% and 21.6% among 10b biopsy technique, respectively. There were no statistical differences between 12 core and 10a core about cancer detection rate. Adding lateral cores to sextant biopsy improves the cancer detection rates. In our study, 12-core biopsy technique increases the cancer detection rate by 5.4% among 10a core but that was not statistically different. On the other hand, 12-core biopsy technique includes all biopsy regimens. We therefore suggest 12-core biopsy or minimum 10-core strategy incorporating six peripheral biopsies with elevated age- specific PSA levels up to 20?ng/mL in patients with renal failure.  相似文献   

18.
Update on prostate biopsy technique   总被引:1,自引:0,他引:1  
PURPOSE OF REVIEW: Over the past decade, a considerable number of modifications have been made to the techniques for prostate cancer biopsy. In this review, we discuss the developments reported in the literature since January 2003. RECENT FINDINGS: The addition of laterally directed biopsies has enhanced the diagnostic performance of the conventional sextant biopsy approach. Several models of the extended biopsy technique have been introduced that increase the number of cores by combining sextant and lateral biopsies to enhance the cancer detection rate. Several reports have shown that the cancer detection rate decreases as prostate volume increases, compared with an increasing cancer detection rate on repeat biopsy in men with large prostate gland volumes. Other studies have shown that the percentage of positive cores and the total percentage of tumor found at biopsy are significant independent predictors of pathological outcome on multivariate analysis. In randomized, double-blind studies, infiltration of the neurovascular bundles with lidocaine significantly reduces pain associated with extended biopsies. SUMMARY: Current reports have suggested that: (1) extended biopsy schemes decrease the false-negative rate compared with conventional sextant biopsy; (2) laterally directed biopsies from the anterior horn should be included in extended biopsy protocols; and (3) local anesthesia reduces pain associated with extended biopsy.  相似文献   

19.
The widespread use of measurement of prostate-specific antigen for prostate cancer screening has led to a dramatic increase in the number of transrectal biopsies. Although transrectal ultrasound-guided prostate biopsy is the gold standard in the diagnosis of prostate cancer, the strategies for initial and repeat biopsies remain controversial. Over the past decade numerous biopsy protocols have been developed. Several protocols have been established that increase the number of cores by combining sextant and lateral biopsies to increase the cancer detection rate. We review the current methods of prostate biopsies, the indication to perform an initial and repeat biopsy, the impact of prostate volume on the number of cores taken, and the morbidity of the procedure.  相似文献   

20.
G Aus  S Bergdahl  J Hugosson  P Lodding  C G Pihl  E Pileblad 《European urology》2001,39(6):655-60; discussion 661
OBJECTIVE: Prostate cancer has its most frequent location in the posterior-lateral part of the gland. The aim of this study was to evaluate the cancer detection rate of six systemic prostate biopsies with mid lobar biopsies taken far laterally in the prostate. PATIENTS AND METHODS: A total of 692 patients (aged 50--66 years) enrolled in a screening study underwent prostate biopsies because of an elevated serum prostate-specific antigen (PSA; > or =3 ng/ml) level. The outcome of the biopsies was related to findings at digital rectal examination (DRE) and transrectal ultrasound (TRUS) and to the location within the prostate. RESULTS: Prostate cancer was detected in 164 patients. DRE and TRUS were suspicious of malignancy in 66 cases (40%) and 84 cases (51%), respectively. The two biopsies taken far laterally midlobar in the prostate detected as many as 83% of the cancers and when combined with two apical biopsies, 96% of all cancers were detected. CONCLUSION: At PSA screening in this age-group, only 57% of the prostate cancers detectable by sextant biopsies were palpable or visible at TRUS. Most of the cancers (96%) were detectable by only four systematic, carefully directed biopsies. In men with normal DRE, the two lateral midlobar biopsies should be taken first during the biopsy procedure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏