Jong Hun Ji Sang Eun Park In Soo Song Hanvit Kang Ji Yoon Ha Jae Jung Jeong 《Clinics in Orthopedic Surgery》2014,6(4):365-372
Background
We report intra- and postoperative complications of unicompartmental knee arthroplasty (UKA).Methods
This study was conducted on 246 cases of UKA which were performed for degenerative osteoarthritis confined to the medial compartment, from May 2002 to May 2010, for which follow-up periods longer than one year were available. Complications were divided into intra- and postoperative complications. Pre- and postoperative clinical scores, the range of motion, and radiologic findings were analyzed.Results
Complications developed in a total of 24 cases (9.8%, 24/246). Among them, 6 cases had intraoperative complications while 18 had postoperative complications. Among the 6 intraoperative complications, one fracture of the medial tibial condyle, two fractures of the intercondylar eminence, one rupture of the medial collateral ligament, one widening of the peg hole leading to femoral component malposition and late failure, and one total knee arthroplasty (TKA) conversion of a large bony defect of tibial avascular necrosis were observed. Among the 18 postoperative complications, four cases of aseptic loosening of the femoral component, one soft tissue impingement due to malalignment, nine cases of polyethylene bearing dislocation, one case of suprapatellar bursitis, one periprosthetic fracture, one TKA conversion due to medial component overhanging, and one TKA conversion due to pain of unexplained cause were observed.Conclusions
The mid-term clinical outcomes of UKA were excellent in our study. However, the incidence of complications was very high (9.8%). To prevent intra- and postoperative complications, proper selection of the patients and accurate surgical techniques are required. 相似文献2.
Hac? Bayram Tosun Abuzer Uluda? Sancar Serbest Seyitali Gümü?ta? ?brahim Halil Erdo?du 《International journal of surgery case reports》2014,5(7):419-423
INTRODUCTION
Nonpigmented villonodular synovitis (non-PVNS) is a benign proliferative disease involving the synovium. It is a rare condition that is little recognized. Non-PVNS has been reported as a cause of total knee replacement failure.PRESENTATION OF CASE
We report a case of extensive diffuse non-PVNS in a patient with tibial component loosening after total knee replacement and review the related literature.DISCUSSION
It is reported that pigmented villonodular synovitis (PVNS) occurs less frequently than non-PVNS after knee replacement. However, there are many more case reports of PVNS than non-PVNS after knee arthroplasty in the English-language literature.CONCLUSION
Previously, there were no reported cases of extensive diffuse non-PVNS after total knee arthroplasty (TKA). This case study highlights an unusual case of non-PVNS as a cause of TKA failure. We propose that non-PVNS should be considered as a differential diagnosis in patients after TKA who present with recurrent pain and effusion/hemarthrosis of the knee, and that it is one of the causes of implant loosening after TKA. 相似文献3.
Philippe Hernigou Pascal Duffiet Didier Julian Issac Guissou Alexandre Poignard Charles Henri Flouzat-Lachaniette 《HSS journal》2013,9(2):134-137
Background
The controversy regarding the outcome of total knee arthroplasties after high tibial osteotomy may relate to malalignment secondary to overcorrection after high tibial osteotomy (HTO) [1, 2] and to the type of arthroplasty itself (posterior-stabilized arthroplasty or posterior cruciate ligament-retaining prosthesis).Questions/Purpose
We asked two questions: (1) Would a posterior-stabilized arthroplasty provide sufficient constrain and improve pain and function in patients with severe malalignment due to a previous HTO? (2) Will malalignment of the previous HTO jeopardize the long-term results of a total knee reconstruction with a posterior-stabilized implant?Patients and Methods
We retrospectively reviewed 25 posterior-stabilized TKAs in 25 patients with severe valgus deformity after HTO (ranging from 10° to 20° of valgus) and compared the results with a series of matched 25 posterior-stabilized TKAs in 25 patients with normocorrection after HTO ranging from 5° of valgus to 5° of varus. Clinical, operative, and radiographic data were reviewed. Minimum follow-up was 10 years after the arthroplasty (average, 15 years; range, 10–20 years).Results
All the knees had standard posterior-stabilized total knee arthroplasty implants. Patients with an overcorrected HTO were more likely to require a soft tissue release to balance the knee. However, Average Knee Society and Function Score improved, respectively, from 48 to 85 and from 50 to 90 points in the severely overcorrected group, versus, respectively, 50 to 89 and 52 to 97 in the normocorrected group, but the range of mobility was superior for patients with normal alignment. Fifteen-year survivorship after the arthroplasty comparison showed no significant difference between the two groups (one revision in each group).Conclusions
Patients with an overcorrected HTO are more likely to require a soft tissue release to balance the knee. However, both groups show improvements in function and pain. With a posterior-stabilized arthroplasty, the degree of deformity has no impact on the longevity of the TKA.Electronic supplementary material
The online version of this article (doi:10.1007/s11420-013-9344-x) contains supplementary material, which is available to authorized users. 相似文献4.
5.
K.T. Rajshekhar M.N. Kumar P. Venugopal Thomas Chandy 《Journal of Clinical Orthopaedics and Trauma》2014,5(4):211-214
Aim
The purpose of this study was to evaluate the efficacy of the enhanced PS femoral component design released in 2008 by DePuy. The patellar clunk syndrome has been reported in a significant number of patients following total knee arthroplasty. Design modifications of the implant have been made to reduce the incidence of the patellar clunk, especially in the posterior substituted designs.Methods
130 total knee replacements performed using the enhanced PS femoral components were followed-up with clinical and radiographic evaluations.Results
Patellar clunk was seen in 3 of the 130 knees (2%). This is much less than the incidence of patellar clunk reported until now.Conclusions
Removal of the sharp ridge in the intercondylar groove in the newer implant seems to have been effective in reducing the incidence of the patellar clunk. It also indicates that the sharp ridge was the most probable cause of the clunk. 相似文献6.
SS Sarmah S Patel G Reading M El-Husseiny S Douglas FS Haddad 《Annals of the Royal College of Surgeons of England》2012,94(5):302-307
INTRODUCTION
The number of total knee arthroplasties performed continues to rise annually and it would be expected that complications, which include periprosthetic fractures, will also therefore become more commonplace. This article reviews the current literature regarding this injury and identifies the treatment principles that enable patients to regain optimal function.METHODS
A comprehensive search of the Pubmed and Embase™ databases was performed to identify relevant articles. Keywords and MeSH (Medical Subject Headings) terms included in the search strategy were ‘periprosthetic fracture(s)’, ‘femur’, ‘tibia’, ‘patella(r)’, ‘complication(s)’, ‘failure(s)’, ‘risk(s)’, ‘prevalence’, ‘incidence’, ‘epidemiology’ and ‘classification(s)’. The search was limited to all articles published in English and reference lists from the original articles were reviewed to identify pertinent articles to include in this review. A total number of 43 studies were identified.RESULTS
Common treatment aims have been identified when managing patients with a periprosthetic fracture around total knee arthoplasty. The main criterion that determines which option to choose is the degree of remaining bone stock and the amount of fracture displacement.CONCLUSIONS
Treatment of a periprosthetic fracture around total knee arthroplasty will either be non-operative, osteosynthesis or revision arthroplasty. It is imperative that a suitable option is chosen and based on the published literature, pathways are outlined to aid the surgeon. 相似文献7.
Amy Steinhoff Victor Hakim Richard H. Walker Clifford W. Colwell Jr. Steven N. Copp 《HSS journal》2015,11(1):50-55
Background
Ceramic-on-ceramic bearing surfaces were developed to provide an alternate to metal-on-polyethylene to decrease wear-induced osteolysis in total hip arthroplasty patients. In an effort to decrease the risk of ceramic acetabular component fracture or damage during implantation, a raised metal rim was added.Questions/Purposes
How many fractures or impingements have occurred in our population of patients with ceramic liners with raised rims?Methods
With IRB-approved consent, a case series was reviewed from a single center registry and 4 of 169 patients were identified who had revision hip surgery with the ceramic liner with a raised metal rim: one for ceramic liner fracture and three for metallosis, pain, and squeaking. Implant alignment and operative findings were reviewed.Results
One ceramic liner fracture and three cases of metallosis from impingement of the femoral neck on the posterior elevated metal rim of the acetabular liner were observed at revision. The femoral neck in each patient had a divot that corresponded to a divot in the posterosuperior liner rim. Three of the four patients had audible squeaking or clicking prior to revision. A total of 3% of patients in this series had clinically significant impingement with this implant type.Conclusion
Acoustic phenomenon in a ceramic on ceramic bearing surface should be investigated with a cross-table lateral radiograph to evaluate component position. If symptomatic impingement is demonstrated, revision should be considered to avoid failure from metallosis or fracture.Electronic supplementary material
The online version of this article (doi:10.1007/s11420-014-9415-7) contains supplementary material, which is available to authorized users.Keyword: total hip arthroplasty, ceramic fracture, metallosis, ceramic bearing, acoustic phenomenon 相似文献8.
Background
Gender disparities in total knee arthroplasty utilization may be due to differences in perceptions and expectations about total knee arthroplasty outcomes. This study evaluates the impact of a decision aid on perceptions about total knee arthroplasty and decision-making parameters among patients with knee osteoarthritis.Methods
Patients with moderate to severe knee osteoarthritis viewed a video about knee osteoarthritis treatments options, including total knee arthroplasty, and received a personalized arthritis report. An adapted version of the Western Ontario and McMaster Universities Osteoarthritis Index was used to assess pain and physical function expectations following total knee arthroplasty before/after the intervention. These scores were compared to an age- and gender-adjusted means for a cohort of patients who had undergone total knee arthroplasty. Decision readiness and conflict were also measured.Results
At baseline, both men and women had poorer expectations about post-operative pain and physical outcomes compared with observed outcomes of the comparator group. Following the intervention, women’s mean age-adjusted expectations about post- total knee arthroplasty pain outcomes improved (Pre: 27.0; Post: 21.8 [p =0.08; 95% CI −0.7, 11.0]) and were closer to observed post-TKA outcomes; whereas men did not have a significant change in their pain expectations (Pre: 21.3; Post: 19.6 [p = 0.6; 95% CI −5.8, 9.4]). Women also demonstrated a significant improvement in decision readiness; whereas men did not. Both genders had less decision conflict after the intervention.Conclusions
Both women and men with osteoarthritis had poor estimates of total knee arthroplasty outcomes. Women responded to the intervention with more accurate total knee arthroplasty outcome expectations and greater decision readiness. Improving patient knowledge of total knee arthroplasty through a decision aid may improve medical decision-making and reduce gender disparities in total knee arthroplasty utilization.Electronic supplementary material
The online version of this article (doi:10.1186/s12891-015-0473-x) contains supplementary material, which is available to authorized users. 相似文献9.
Borrione F Bonnevialle P Mabit C Guingand O Bertin D Bonnomet F Denis C Gagna G 《International orthopaedics》2011,35(12):1777-1782
Purpose
Our goal was to evaluate the five-year follow-up results of the Scorpio single radius total knee arthroplasty.Method
We performed a retrospective study based upon a multicentre database to evaluate the minimum five-year follow-up clinical and radiological results of 747 patients (831 knees) who underwent primary Scorpio single radius total knee arthroplasty.Results
The mean age of the patients was 71.9 years. At a minimal five-year follow-up, 141 patients were lost to follow-up, 83 patients had died, eight patients had undergone revision of a component, and the remaining 589 patients (602 knees) had a complete clinical and radiological evaluation after a median of six years (range, 5–8). The mean clinical component of the knee score was 92.2 points, and the mean functional component of the knee score was 76.9 points. At last follow-up, 530 of the 602 knees were rated as excellent or good. Only four knees developed patellar complications requiring revision. The survival rate at six years was 95.2% ± 1.9% and 98.3% ± 0.6 with revision for any reason and revision for mechanical failure as the end point, respectively.Conclusion
This medium-term study indicates favourable clinical and radiological results for this single flexion-extension radius design arthroplasty, with a low complication rate on the patellar side. 相似文献10.
Patient characteristics affecting the prognosis of total hip and knee joint arthroplasty: a systematic review
下载免费PDF全文
![点击此处可从《Canadian journal of surgery》网站下载免费的PDF全文](/ch/ext_images/free.gif)
Pasqualina L. Santaguida Gillian A. Hawker Pamela L. Hudak Richard Glazier Nizar N. Mahomed Hans J. Kreder Peter C. Coyte James G. Wright 《Canadian journal of surgery》2008,51(6):428-436
Background
Total joint arthroplasty is a highly efficacious and cost-effective procedure for moderate to severe arthritis in the hip and knee. Although patient characteristics are considered to be important determinants of who receives total joint arthroplasty, no systematic review has addressed how they affect the outcomes of total joint arthroplasty. This study addresses how patient characteristics influence the outcomes of hip and knee arthroplasty in patients with osteoarthritis.Methods
We searched 4 bibliographic databases (MEDLINE 1980–2001, CINAHL 1982–2001, EMBASE 1980–2001, HealthStar 1998–1999) for studies involving more than 500 patients with osteoarthritis and 1 or more of the following outcomes after total joint arthroplasty: pain, physical function, postoperative complications (short-and long-term) and time to revision. Prognostic patient characteristics of interest included age, sex, race, body weight, socioeconomic status and work status.Results
Sixty-four of 14 276 studies were eligible for inclusion and had extractable data. Younger age (variably defined) and male sex increased the risk of revision 3-fold to 5-fold for hip and knee arthroplasty. The influence of weight on the risk of revision was contradictory. Mortality was greatest in the oldest age group and among men. Function for older patients was worse after hip arthroplasty (particularly in women). Function after knee arthroplasty was worse for obese patients.Conclusion
Although further research is required, our findings suggest that, after total joint arthroplasty, younger age and male sex are associated with increased risk of revision, older age and male sex are associated with increased risk of mortality, older age is related to worse function (particularly among women), and age and sex do not influence the outcome of pain. Despite these findings, all subgroups derived benefit from total joint arthroplasty, suggesting that surgeons should not restrict access to these procedures based on patient characteristics. In addition, future research needs to provide standardized measures of outcomes. 相似文献11.
David G. Chess R. Wayne Grainger Tom Phillips Zane D. Zarzour Bruce R. Sheppard 《Canadian journal of surgery》1996,39(5):389-392
Objective
To review the clinical performance of the anatomic medullary locking (AML) femoral stem in total hip arthroplasty.Design
A clinical and radiographic review.Setting
A tertiary lower limb joint replacement centre.Patients
Two hundred and twenty-one patients with noninflammatory gonarthrosis.Interventions
Two hundred and twenty-seven primary total hip arthroplasties with the noncemented AML component completed by two surgeons.Main Outcome Measures
Independent review by two experienced reviewers of the postoperative Harris hip score, radiographs of component fixation, size and degree of diaphyseal fill.Results
Harris hip score was 84 (range from 43 to 98); component fixation showed bone ingrowth in 41%, stable fixation with fibrous ingrowth in 56% and unstable fixation in 3%; severe thigh pain in 4% of cases correlated with unstable fixation, and there was mild thigh pain in 20% of cases.Conclusion
The AML femoral stem performs well in replacement arthroplasty compared with other noncemented stems. 相似文献12.
Lustig S Scholes CJ Stegeman TJ Oussedik S Coolican MR Parker DA 《International orthopaedics》2012,36(9):1835-1839
Purpose
Flexion contracture has been shown to impair function and reduce satisfaction following total knee arthroplasty (TKA). The aim of this study was to identify modifiable intra-operative variables that predict post-TKA knee extension.Methods
Data was collected prospectively on 95 patients undergoing total knee arthroplasty, including pre-operative assessment, intra-operative computer assisted surgery (CAS) measurements and functional outcome including range of motion at one year. Patients were divided into two groups: those with mild flexion contracture (> 5°) at the one-year follow-up and those achieving full extension.Results
The sagittal orientation of the distal femoral cut differed significantly between groups at the one-year follow-up (p = 0.014). Sagittal alignment of greater than 3.5° from the mechanical axis was shown to increase the relative risk of a mild flexion contracture at one-year follow-up by 2.9 times, independent of other variables.Conclusion
Increasing the sagittal alignment of the distal femoral cut more than 3.5° from the mechanical axis is an independent risk factor for clinically detectable flexion contracture one year from index procedure. 相似文献13.
K. Sue Robinson David R. Anderson Michael Gross David Petrie Ross Leighton William Stanish David Alexander Michael Mitchell William Mason Bruce Flemming Marlene Fairhurst-Vaughan Michael Gent 《Canadian journal of surgery》1998,41(5):368-373
Objective
To determine whether compression ultrasonography or clinical examination should be considered as screening tests for the diagnosis of deep vein thrombosis (DVT) after total hip or knee arthroplasty in patients receiving warfarin prophylaxis postoperatively.Design
A prospective cohort study.Setting
A single tertiary care orthopedic centre.Patients
One hundred and eleven patients who underwent elective total hip or knee arthroplasty were enrolled. Postoperatively the warfarin dose was adjusted daily to maintain the international normalized ratio between 1.8 and 2.5. Eighty-six patients successfully completed the study protocol.Intervention
Before they were discharged from hospital, patients were assessed for DVT by clinical examination, bilateral compression ultrasonography of the proximal venous system and bilateral contrast venography.Results
DVT was found in 29 patients (34%; 95% confidence interval [CI] 24% to 45%), and 6 patients (7%; 95% CI 3% to 15%) had proximal DVT. DVT developed in 18 (40%) of 45 patients who underwent total knee arthroplasty and in 11 (27%) of 41 patients who underwent total hip arthroplasty. The sensitivity of compression ultrasonography for the diagnosis of proximal DVT was 83% (95% CI 36% to 99%) and the specificity was 98% (95% CI 91% to 99%). The positive predictive value of compression ultrasonography was 71%. In contrast, clinical examination for DVT had a sensitivity of 11% (95% CI 2% to 28%) and a positive predictive value of 25%.Conclusions
DVT is a common complication after total hip or knee arthroplasty. Compression ultrasonography appears to be a relatively accurate noninvasive test for diagnosing postoperative proximal DVT. In contrast, clinical examination is a very insensitive test. Whether routine use of screening compression ultrasonography will reduce the morbidity of venous thromboembolism after joint arthroplasty requires confirmation in a prospective trial involving long-term follow-up of patients. 相似文献14.
Nishikant Kumar Chandrashekhar Yadav Swapnil Singh Ashok Kumar Aruljothi Vaithlingam Sanjay Yadav 《Journal of Clinical Orthopaedics and Trauma》2015,6(2):85-88
Aim
Thigh pain following tourniquet application is a common complaint in early post operative period following total knee arthroplasty.Method
Post operative Thigh pain was evaluated in 30 consecutive simultaneous bilateral total knee arthroplasty patients between July 2013 and January 2014. Patient thigh pain was evaluated with the VAS score. The scale was applied on first, second, third day & second and six weeks after surgery.Result
There were statistically significant difference in VAS score in non-tourniquet group on first, second, third post operative day. We did not find statistically significant difference at Second and Six weeks post operatively.Conclusion
This Randomized trial demonstrates that non-tourniquet use in TKA has less early postoperative pain and leads to better recovery. 相似文献15.
Gurava Reddy V Krishna Mootha A Chiranjeevi T Kantesaria P Kumar Ramireddy V Reddy D 《International journal of surgery case reports》2011,2(7):175-177
Introduction
Periprosthetic fracture following total knee arthroplasty is a potentially serious condition. Here we report a case of bilaterally symmetrical (mirror) fracture of supracondylar area following trivial trauma.Presentation of case
Both fractures were OTA 33A2 and according to Rorabeck classification they were type II. Both fractures were fixed by dual plating technique using non locking plates. Intra operative fracture site biopsy revealed marked osteopenia and hence the patient was treated for osteoporosis.Discussion
Both fractures united well at 14 weeks. At final follow up of 6 years there were no radiological signs of implant loosening and the patient was able to walk without any aids and had a range of 80° and 60° flexion in the right and left knees respectively.Conclusion
We conclude that in the pre locking plate''s era such difficult case has been successfully managed by dual plating technique. 相似文献16.
U Butt R Ahmad D Aspros GC Bannister 《Annals of the Royal College of Surgeons of England》2011,93(1):54-56
INTRODUCTION
Wound ooze is common following total knee arthroplasty (TKA) and persistent wound infection is a risk factor for infection, and increased length and cost of hospitalisation.PATIENTS AND METHODS
We undertook a prospective study to assess the effect of tourniquet time, peri-articular local anaesthesia and surgical approach on wound oozing after TKA.RESULTS
The medial parapatellar approach was used in 59 patients (77%) and subvastus in 18 patients (23%). Peri-articular local anaesthesia (0.25% Bupivacaine with 1:1,000,000 adrenalin) was used in 34 patients (44%). The mean tourniquet time was 83 min (range, 38–125 min). We found a significant association between cessation of oozing and peri-articular local anaesthesia (P = 0.003), length of the tourniquet time (P = 0.03) and the subvastus approach (P = 0.01).CONCLUSIONS
Peri-articular local anaesthesia, the subvastus approach and shorter tourniquet time were all associated with less wound oozing after total knee arthroplasty. 相似文献17.
Purpose
Several authors have observed that standard instrumentation (SI) may be insufficient for addressing component malalignment. Patient-matched cutting blocks (PMCB) technology was introduced to improve surgeons’ ability to achieve a neutral postoperative mechanical axis following total knee arthroplasty (TKA). The current retrospective study was designed to compare the ability of SI and PMCB to achieve a hip-knee-ankle angle (HKA) within ±3° of the ideal alignment of 180°.Methods
Between October 2009 and December 2012, 170 TKAs in 166 patients (four bilateral) using VISIONAIRE (Smith & Nephew) PMCB technology were performed. Additionally, 160 TKAs in 160 consecutive patients that had received a total knee arthroplasty using SI during the same time period were used as a control group, All surgeries were performed by the same surgeon. Standardized pre- and postoperative long-leg standing x-rays were retrospectively evaluated to compare the two patient cohorts.Results
X-rays were available for analysis for 156 knees in the SI group and 150 in the PMCB group. The average post-surgical HKA was 178.7 ± 2.5 in the SI group and 178.4 ± 1.5 in the PMCB group. However, the rate of ± 3° outliers was 21.2 % in the SI group and 9.3 % in the PMCB group. There were no intraoperative complications with the use of PMCB technology or SI.Conclusions
PMCB technology proved superior to conventional instrumentation in achieving a neutral mechanical axis following TKA. Further follow-up will be needed to ascertain the long-term impact of these findings. 相似文献18.
Till O. Klatte Reza Sabihi Daniel Guenther Atul F. Kamath Johannes M. Rueger Thorsten Gehrke Daniel Kendoff 《HSS journal》2015,11(3):198-203
Background
Existing hardware may contribute to increased risk of bacterial contamination and subsequent periprosthetic joint infection (PJI) in conversion shoulder arthroplasty performed for failed fracture fixation.Questions/Purposes
This study examined the incidence of positive pre-operative aspiration and inflammatory marker data, along with correlation of pre-operative positive aspiration or inflammatory markers and subsequent infection following conversion shoulder arthroplasty for failed open reduction and internal fixation (ORIF) and the need for re-operation at 4.6-year follow-up.Methods
Twenty-eight patients who underwent conversion to shoulder arthroplasty for any reason after fracture fixation were retrospectively reviewed in a single center. A pre-operative aspiration was done in 17 patients; all patients had intra-operative tissue sampling. All procedures were single-stage removal of hardware and performance of the arthroplasty. In cases of pre-operative positive bacterial growth, a single-stage procedure was performed according to the septic ENDO-Klinik protocol.Results
In 4 of 17 pre-operative joint aspirations, bacterial growth was detected; one pre-operative negative aspiration demonstrated bacterial growth in intra-operative sampling. In three of them, the infection has been validated through intra-operatively results. Pre-operative aspiration showed a sensitivity of 75% and specificity of 92% (p < 0.005) for infection. No post-operative PJIs were observed. Six revisions were performed, most commonly for aseptic loosening (two cases) and conversion of hemiarthroplasty to a reverse design (two cases).Conclusions
In conclusion, the risk of low-grade shoulder infection after fracture osteosynthesis may be higher than in hip and knee joints, based on limited study data. Adequate pre-operative testing is recommended to rule out occult shoulder infection in this setting.Electronic supplementary material
The online version of this article (doi:10.1007/s11420-015-9450-z) contains supplementary material, which is available to authorized users. 相似文献19.
Is etoricoxib effective in preventing heterotopic ossification after primary total hip arthroplasty?
Jaap J. Brunnekreef Paul Hoogervorst Marieke J. Ploegmakers Wim H. Rijnen Berend W. Schreurs 《International orthopaedics》2013,37(4):583-587
Purpose
Heterotopic ossification is a common complication after total hip arthroplasty. Non-steroidal anti-inflammatory drugs (NSAIDs) are known to prevent heterotopic ossifications effectively, however gastrointestinal complaints are reported frequently. In this study, we investigated whether etoricoxib, a selective cyclo-oxygenase-2 (COX-2) inhibitor that produces fewer gastrointestinal side effects, is an effective alternative for the prevention of heterotopic ossification.Methods
We investigated the effectiveness of oral etoricoxib 90 mg for seven days in a prospective two-stage study design for phase-2 clinical trials in a small sample of patients (n = 42). A cemented primary total hip arthroplasty was implanted for osteoarthritis. Six months after surgery, heterotopic ossification was determined on anteroposterior pelvic radiographs using the Brooker classification.Results
No heterotopic ossification was found in 62 % of the patients that took etoricoxib; 31 % of the patients had Brooker grade 1 and 7 % Brooker grade 2 ossification.Conclusions
Etoricoxib seems effective in preventing heterotopic ossification after total hip arthroplasty. This finding further supports the use of COX-2 inhibitors for the prevention of heterotopic ossification following total hip arthroplasty. 相似文献20.
Osamu Tanifuji John David Blaha Shin Kai 《Clinical orthopaedics and related research》2013,471(3):1014-1020