首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Attempts at improving anastomoses have included the development of stapling techniques. Our purpose was to evaluate arcuate-legged clipped versus standard sutured anastomoses of the hepatic artery (HA), portal vein (PV), and bile duct in a porcine liver transplantation model. Two groups of pigs were studied intraoperatively and 1 day after liver transplantation. A control group underwent sutured anastomosis of PV and HA with polypropylene and of bile duct with polydioxanone (n = 8). An experimental group underwent anastomoses with arcuate-legged clips (n = 8). We analyzed the time to perform anastomosis and flows before and at various time points after anastomosis. In addition, patency and histology of the anastomoses were evaluated 1 day after operation, including a fibrin-thrombosis score, medial injury, and inflammation score. Times to complete HA and PV anastomoses were not different between clipped and sutured groups. However, the time was shorter to complete bile duct anastomosis with clips than with sutures (6.3 +/- 1.1 minutes and 13.3 +/- 2.0 minutes, respectively). Flows through HA anastomoses were not different between groups, but flow through the PV was higher in clipped compared with sutured anastomosis (P = 0.06). Patency was 100 per cent with no leaks for all three anastomoses in both groups. Histologic data were similar between vascular anastomotic groups. Sutured bile duct anastomoses revealed mild smooth muscle injury in 75 per cent whereas clipped bile duct anastomoses displayed no smooth muscle injury. We conclude that arcuate-legged clipped anastomosis represents a viable option to sutured anastomoses of the PV, HA, and bile duct anastomoses. Bile duct anastomoses were completed in less than half the time and with less tissue damage documented histologically.  相似文献   

2.
To date, the gold standard for performing a microvascular anastomosis has been the penetrating suture with attached needle. During the last two decades, non-penetrating techniques have been introduced, including the Unilink system for end-to-end anastomoses, and the VCS clip-applier system for both end-to-end and end-to-side anastomoses. The aim of this study was to compare the results of different techniques used to create microvascular anastomoses in free-flap reconstructions. Between January 1995 and October 1999, we performed 474 microvascular anastomoses in 216 consecutive free-tissue transfers. The anastomosis techniques included manual sutures (42%), Unilink rings (34%) and VCS clips (24%). Seven combined sutured-clipped anastomoses were excluded from further analysis. The mean anastomotic time when rings were applied was significantly shorter than when using clips (P 0.0001) or sutures (P 0.0001). Venous anastomoses using clips took less time than those using sutures (P 0.05). There were 19 anastomotic failures, all of which lead to early flap failure. Ten flaps were salvaged by early reoperation; nine flaps were lost. Three more flaps were lost as a result of other causes, bringing the flap survival rate down to 94.4%. Early flap failure was caused by failure of the arterial anastomosis in eight cases; all of them were sutured (these represented 5% of all arterial anastomoses with sutures). None of the clipped arterial anastomoses failed. Early flap failure was caused by failure of the venous anastomosis in 11 patients. Three of these anastomoses were sutured (representing 6% of all venous anastomoses with sutures), seven were anastomosed with rings (representing 5% of all venous anastomoses with rings) and one was clipped (representing 2% of all venous anastomoses with clips). Both the VCS clip-applier system and the Unilink system are easy to handle and allow fast microvascular anastomoses without intraluminal penetration. The patency rate of clipped vessels is at least as good as the patency rates of vessels anastomosed using sutures or rings.  相似文献   

3.
This study compared the healing of laser-welded and sutured canine femoral arteriovenous anastomoses. Arteriovenous fistulas 2 cm in length were created bilaterally in the femoral vessels of 10 dogs and were studied at 1 (n = 2), 2 (n = 2), 4 (n = 3), and 8 (n = 3) weeks. In each animal, one anastomosis (control) was closed with running 6-0 polypropylene sutures, and the contralateral anastomosis (experimental) was sealed with an argon laser (0.5 watt, 4 minutes of exposure, 1830 J/cm2/1 cm length of anastomosis). At removal all experimental anastomoses were patent without hematomas, aneurysms, or luminal narrowing. Histologic examination at 4 weeks revealed that laser-welded anastomoses had less inflammatory response and almost normal collagen and elastin reorientation. At 8 weeks sutured anastomoses had significant intimal hyperplasia whereas laser repairs had normal luminal architecture. Tensile strength and collagen production, measured by the synthesis of hydroxyproline and the steady-state levels of type I and type III procollagen messenger ribonucleic acids, at the anastomoses and in adjacent vein and artery specimens were similar in sutured and laser-welded repairs at 2, 4, and 8 weeks. We conclude that argon laser welding of anastomoses is an acceptable alternative to suture techniques, with the advantage of improved healing without foreign body response and possible diminished intimal hyperplasia at the anastomotic line.  相似文献   

4.
PURPOSE: The gross, light microscopic, and scanning microscopic appearance of arterial and venous anastomoses in expanded polytetrafluoroethylene (ePTFE) access grafts constructed with nonpenetrating clips were compared with that of those constructed with polypropylene suture. We hypothesized that clip-constructed anastomoses would provide controlled approximation of native vessel intimal and medial components with the ePTFE grafts. We further hypothesized that anastomotic healing with clips would involve primarily an intimal cellular response, as compared with suture-constructed anastomoses in which cells within the media and adventitia walls participate. METHODS: Femoral artery to femoral vein arteriovenous (AV) grafts were constructed in five dogs using 4-mm internal diameter ePTFE graft material. Each animal received one AV graft with anastomoses constructed by using polypropylene sutures in one leg and one AV graft with anastomoses constructed with Vascular Closure System clips in the contralateral leg. Animals were given aspirin for the duration of the study, and grafts were explanted at 5 weeks. At the time of explantation, graft segments were grossly evaluated and then underwent light and scanning electron microscopic analysis. RESULTS: At the time of explantation, all access grafts were patent. Joining the ePTFE grafts to the native vessels with clips resulted in minimal vessel wall damage. The lumenal contours of the discontinuous approximation were smooth and without gross endothelial disruption. These observations are in contrast to the lumenal compromise and endothelial disturbance associated with the sutured anastomoses. Furthermore, hemostasis was achieved immediately in the clipped grafts, decreasing the incidence of perianastomic hematoma. Finally, cellular reconstitution occurred at the anastomotic cleft in both the sutured and the clipped junctions. The neointima exhibited an endothelial cell lining on the lumenal surface and the presence of alpha-smooth muscle cell actin positive cells within the subendothelial layer. CONCLUSION: Vascular Closure System clips are a viable alternative to suture for the approximation of ePTFE AV access grafts to native blood vessels. The use of the clips resulted in a more streamlined anastomosis, with decreased vessel wall damage, immediate hemostasis, and a trend toward shorter procedure times.  相似文献   

5.
Vascular closure staples (VCS) provide a novel technique for fashioning vascular anastomoses, allowing a single operator to perform suture-less anastomoses. They may be used primarily or in an adjuvant role. When VCS are compared to a running suture, advantages include the avoidance of intimal damage, platelet aggregation and intimal hyperplasia at the anastomotic suture line, and a shorter time taken to complete the anastomosis. We report our early experience using VCS in an array of vascular anastomoses and conclude that VCS are a useful addition to the vascular surgeon's armamentarium. They help to decrease the time taken to construct an anastomosis, and are particularly useful in an adjuvant setting, complementing conventionally placed sutures.  相似文献   

6.
Zdolsek J  Ledin H  Lidman D 《Microsurgery》2005,25(8):596-598
Sutured anastomoses of small vessels are considered difficult to learn. Mechanical anastomosis systems allow a more rapidly performed anastomosis. In order to compare the process of learning to perform sutured and mechanical microvascular anastomoses, two surgeons, with limited microvascular experience, performed 30 aortic and 30 femoral vein anastomoses in 30 Wistar rats. The methods compared were conventional suture, vascular closure system (VCS) and microvascular anastomatic coupler system (MAC). There were no inter-surgeon differences regarding patency or time to perform anastomoses. The average time to perform a suture anastomosis was 39 min (patency 80%). Anastomoses with the VCS system took 24 min (patency 25%), whereas the MAC couplers took 13 min to perform (patency 95%). There was a significant learning effect with sutures, but no obvious reduction in time to perform MAC coupler or VCS clip anastomoses was seen. MAC couplers were easiest to use, and allowed us to perform rapid anastomoses with high patency.  相似文献   

7.
PURPOSE: Vein collars and patches are used at the distal anastomoses of infrainguinal prosthetic grafts to improve graft patency. We initiated a randomized, prospective study to determine whether a Tyrell vein collar at the venous anastomosis of forearm loop arteriovenous grafts (AVGs) would improve patency. METHODS: Patients who required new forearm AVGs were randomized to (1) a standard end-to-side graft-vein anastomosis (control group) or (2) a Tyrell vein collar between the graft and the vein (study group). End points were (1) graft thrombosis, (2) graft removal and ligation, or (3) inadequate graft function. Randomization of 75 subjects was planned. The study was terminated early for ethical reasons. RESULTS: Seventeen patients (eight men, nine women) with a mean age of 52.8 years (range, 31-79 years) had 17 grafts placed (control group, n = 10; study group, n = 7). Comorbidities were not different between the groups (P>.05). Six (86%) of seven study grafts failed by 9 months (mean, 4.6 months). Four (66%) failed study grafts had venous outflow tract stenosis from intimal hyperplasia. This was confirmed at surgery in three and by angiography in one. The 9-month primary patency was 80% for the control group versus 17% for the study group (P =.015). Smaller outflow vein diameter in the study group (P =. 048) did not account for this inferior graft patency. CONCLUSION: A Tyrell vein collar at the venous anastomosis of a forearm AVG resulted in premature graft failure. The use of a Tyrell vein collar may accelerate venous anastomosis intimal hyperplasia.  相似文献   

8.
OBJECTIVE: There is some evidence to suggest that prosthetic distal bypass graft patency can be improved, and the risk of intimal hyperplasia diminished, by interposing a distal vein cuff. We studied intimal remodeling in an end-to-side distal prosthetic anastomosis constructed with and without a vein cuff. METHODS: Twenty-four prosthetic bypasses were constructed with (N=12) or without (N=12) a distal vein cuff in 12 pigs. At 10 weeks, the 20 anastomoses and adjacent arteries from the surviving 10 pigs were studied by histology, immunohistochemistry and morphometry. RESULTS: Intimal hyperplasia was significantly less on all zones of the arterial floor and all suture zone of arteries anastomosed with a vein cuff than within arteries anastomosed without a vein cuff (0.11 versus 0.34; p=0.001 and 0.35 versus 1.19; p=0.0001, respectively). Intimal hyperplasia was also more prominent within the vein cuff than within the recipient artery, with or without a vein cuff (1.35 versus 0.38; p=0.0001). CONCLUSION: An interposition vein cuff at the distal anastomosis between a prosthesis and an artery alters the distribution of intimal hyperplasia. By acting as an expansion chamber where intimal hyperplasia can develop harmlessly, the vein cuff may protect the arterial anastomosis from stenosis.  相似文献   

9.
BACKGROUND AND OBJECTIVES: To improve minimally invasive direct coronary artery bypass surgery (MID-CAB), new techniques of vascular anastomosis that are faster and more reliable need to be developed. STUDY DESIGN/MATERIALS AND METHODS: Common carotids in a canine model were transected and an end-to-end anastomosis was performed by using one of four techniques (1) continuous 6-0 polypropylene closure (suture; n=6), (2) vascular clip (VCS; n=6), laser welding using 50% albumin solder with (3) a 1.32-micro laser (1.32las; n=6), and (4) a 1.9-micro diode laser (1.9las; n=4). Times for anastomosis (TA) were compared between groups by t-test. Pressures at which anastomosis failed (leak point pressure, LPP) were determined and compared by analysis of variance. RESULTS: TA was faster for 1.32las and 1.9las at 8.4+/-0.7 and 7.8+/-0.3 min, respectively, when compared with suture at 13.8+/-1.0 min (P=0.001, confidence interval [CI]-8.1, -2.6 for 1.32las and CI -8.9, -3.1 for 1.9las). There was no statistical difference between VCS (8.3+/-3.3 min) and any other group (P > 0.17). LPPs (mm Hg) were similar for all groups: 350+/-37 for 1.32las, 280+/-31 for 1.9las, 347+/-46 for suture, and 358+/-53 for VCS, P=0.68. CONCLUSIONS: In this study, laser welding using 50% human albumin solder resulted in faster anastomotic times. Anastomoses were equivalent to conventional sutured anastomoses in failing at similar pressures. Laser welding using human albumin solder may be advantageous in improving coronary anastomoses during MID-CAB, but long-term anastomotic strength and histologic evaluation need to be investigated.  相似文献   

10.
OBJECTIVE: Late graft failure is still a significant problem, particularly in cases with poor runoff vessels. The main cause of late graft failure is intimal thickening of the anastomotic region. Vascular closure system (VCS) clips may provide ideal anastomosis, since they do not penetrate the wall. Therefore, we examined whether the VCS clips affect intimal thickening under poor runoff conditions in the canine autogenous vein grafts. METHODS: A canine poor runoff model was prepared at both femoral veins. Four weeks after the first surgical procedure, two groups were established according to the two different methods of anastomosis employed. The right femoral vein graft was performed using polypropylene sutures, conventional surgical anastomosis (control group), while the left femoral vein graft was performed using VCS clips anastomosis (VCS group). Four weeks after grafting, the vein grafts were removed and the intimal thickening of proximal, distal anastomosis and midportion of the vein grafts were examined histologically. RESULTS: In the control group, flow rate and variation were 26+/-8 ml/min and 51+/-10 dynes/cm(2), respectively. In the VCS group, the flow rate and variation were 23+/-11 ml/min and 44+/-14 dynes/cm(2), respectively. There were no significant differences between the two groups. The average value of intimal thickening of both the anastomotic region and the midportion of the vein graft in the VCS group was significantly inhibited compared to that of the control group. The number of positive cells of masson trichrome stain in the VCS group was significantly less than that of the control group. CONCLUSIONS: These experiments indicate that VCS clips significantly inhibit intimal thickening under poor runoff conditions in canine autogenous vein grafts to a greater extent compared to suture-constructed anastomosis. One mechanism that may account for the decreased intimal thickening is the inhibition of the expression of transforming growth factor-beta (TGF-beta), because the number of positive cells of masson trichrome stain in the VCS group was significantly less than that of the control group.  相似文献   

11.
Tissue fusion using laser energy is a promising new technology that may improve the healing of anastomoses. This study evaluated the feasibility of using argon laser energy to fuse vascular tissue and biologic vascular prostheses (St. Jude Medical, Inc.) in a canine arteriovenous (A-V) fistula model. Five animals had 4-cm length, 3-mm internal diameter grafts (n;eq 10) placed bilaterally as side-to-side A-V interpositions from the femoral artery to femoral vein. One A-V graft was placed using argon laser energy with the vessel edges aligned by 6-0 polypropylene traction sutures at 3 to 4 mm intervals. The contralateral graft was sutured using running 6-0 polypropylene suture. Anastomoses were successfully fashioned in all animals except for episodes of delayed bleeding at two laser-fused segments (15 min and 2 hrs) and one segment in a suture control (6 days). The implants were removed to evaluate the integrity and healing of the anastomoses at 2 hrs, 8 days, and at 7, 9, and 11 weeks. In all instances, there was no evidence of anastomotic dehissance or enlargement. Histologic examination of the anastomoses revealed coapted vessel and prosthetic edges in laser-fused specimens and a limited foreign-body response to the permanent sutures in the suture controls. In the longer term specimens there was marked intimal proliferation at the venous anastomosis in all implants, with recent bilateral occlusions of the 7 and 11 week implants at the venous connection. We conclude that laser fusion of biologic vascular prostheses to autogenous vessel is possible with healing and no evidence of anastomotic dehissance. The technique may provide a method to limit development of anastomotic stenosis by eliminating the foreign body reaction. In addition, the canine arteriovenous model used in these experiments develops aggressive intimal lesions at the venous anastomosis within weeks and may be used to evaluate the effect of anastomotic technique on the development of this lesion.  相似文献   

12.
OBJECTIVE: The aim of this study is to determine whether adenoviral inducible nitric oxide synthase (iNOS) gene transfer could inhibit intimal hyperplasia (IH) in porcine internal jugular veins interposed into the carotid artery circulation. METHODS: Porcine internal jugular veins were transduced passively with 1 x 10(11) particles of an adenoviral vector carrying either the human iNOS (AdiNOS) or beta-galactosidase (AdlacZ) cDNA for 30 minutes and then interposed into the carotid artery circulation. Segments of each vein graft were maintained in an ex vivo organ culture to measure nitrite accumulation, a marker of nitric oxide synthesis. The grafts were analyzed immunohistochemically for the presence of neutrophils, macrophages, and leukocytes by staining for myeloperoxidase, ED1, and CD45, respectively, at 3 (n = 4) and 7 (n = 4) days. Morphometric analyses and cellular proliferation (Ki67 staining) were assessed at 3 (n = 4), 7 (n = 4), and 21 days (n = 8). RESULTS: AdlacZ-treated vein grafts demonstrated high levels of beta-galactosidase expression at 3 days with a gradual decline thereafter. Nitrite production from AdiNOS-treated vein grafts was approximately fivefold greater than AdlacZ-treated grafts (P =.00001). AdiNOS or AdlacZ treatment was associated with minimal graft inflammation. Cellular proliferation rates were significantly reduced in AdiNOS-treated grafts as compared with controls at both 3 (41%, P =.000004) and 7 days (32%, P =.0001) after bypass. This early antiproliferative effect was most pronounced at the distal anastomosis (65%, P =.0005). The iNOS gene transfer reduced the intimal/medial area ratio in vein grafts at 7 (36%, P =.009) and 21 days (30%, P =.007) versus controls. This inhibition of IH was again more prominent in the distal segments of the grafts (P =.01). CONCLUSION: Adenovirus-mediated iNOS gene transfer to porcine internal jugular vein grafts effectively reduced cellular proliferation and IH. Although iNOS gene transfer reduced IH throughout the entire vein graft, the most pronounced effect was measured at the distal anastomosis. These results suggest potential for iNOS-based genetic modification of vein grafts to prolong graft patency.  相似文献   

13.
An experimental microvenous thrombosis model was developed combining vein grafting in femoral vein defects with exaggerated vessel injuries using a knotted suture in the vessel repair. The rat femoral vein grafts were separately subjected to injuries caused by an anastomosis performed with a suture knotted with eight half-hitches at the distal anastomosis (upstream), the proximal anastomosis (downstream), and both anastomotic sites. These groups were compared to vein grafting done with a standard suture. Vessel patency was assessed at 20 min and 24 hr, and the thrombus component was histologically analyzed at 24 hr after the procedures. One hundred percent of control vein grafts were patent at 24 hr. All experimental groups had significantly decreased patency at 24 hr (P<0.001). Among the experimental groups, knotted suture anastomoses at both anastomoses produced significantly lower patency (13.3%, P<0.05) than knotted suture anastomoses at distal anastomoses. Histological analyses of thrombosed grafts showed that a large amount of thrombocyte deposition and inflammatory cells were noted at both anastomotic sites in the vein grafts with a knotted suture at the distal anastomosis and in the grafts with a knotted suture at both anastomoses. Thrombocyte deposition and inflammatory cells were seen only at the site of proximal anastomosis when using a knotted suture at the proximal anastomosis site alone. This study demonstrated that quantified microvenous thrombosis can be produced by exaggerating vessel injuries with a knotted suture in a vein graft model. This thrombosis model can be used to study the effects of antithrombogenic agents. © 1995 Wiley-Liss, Inc.  相似文献   

14.
BACKGROUND: A new stainless steel anastomosis device developed by St. Jude Medical Cardiovascular Group was studied in a canine model. METHODS: In 12 dogs, coronary saphenous vein grafts were made to the left anterior descending coronary artery and to the circumflex coronary artery; one anastomosis was completed with the St. Jude Medical stainless steel connector device, and the other with conventional suturing. A 30-day coronary angiogram was performed in surviving animals, and, after sacrifice, anastomoses were measured, examined grossly, and submitted for histologic study. RESULTS: All 12 animals survived the procedure, and 9 survived to sacrifice at 30 days. Comparing the connector grafts and sutured grafts, no significant differences were found between vessel diameters, intraoperative graft flows, graft patency, and histology. The average loading time for the connector was 8.5 minutes (range 4 to 16 minutes). Mean time for the 12 connector anastomoses was 3 minutes (range 2 to 5 minutes) compared with 8.4 minutes for suture (range 4 to 13 minutes). CONCLUSIONS: The side-to-side stainless steel connector anastomotic device produces a secure anastomosis with minimal variability; compared with suture methods, it is expeditious and has comparable 30-day histology and angiographic results. It promises to be an important addition to the surgical armamentarium for the treatment of coronary artery disease.  相似文献   

15.
OBJECTIVE: Narrowing of vascular anastomoses is a frequently encountered surgical problem, with intimal hyperplasia being one of its most important causes. The aim of the present study was to compare in a rabbit model 'manual' (hand-sewn) with 'stapled' anastomoses (using a staple device) with respect to occurrence and severity of intimal hyperplasia. MATERIALS AND METHODS: Twenty-four male rabbits (mean weight 2,849 g) were randomly allocated to one of two groups (n = 12). An end-to-end anastomosis of the left femoral artery was performed in all animals under general anesthesia. The anastomosis was hand sewn in group 1, while a vascular closure stapler (VCS) was used in group 2. Both anastomotic time and total operation time were recorded. After 28 days, the rabbits were sacrificed. The femoral artery of operated and nonoperated sides were removed and prepared for anatomopathological examination. The I/M ratio (= difference between tunica intima and tunica media) was determined on hematoxylin-eosin stained slides. All results were analyzed using Student's t test. RESULTS: Mean anastomotic times were 25 +/- 7 min for the 'manual' group and 17 +/- 9 min for the 'stapled' group (p = 0.02). There was no significant difference in the total operation time (55 +/- 15 vs. 41 +/- 18 min, p = 0.057). All animals survived the anastomosis procedure. In the group of 'manual' anastomosis, morbidity was significantly higher. At the moment of sacrifice, all anastomoses were patent. There was no difference in the I/M ratio between the groups. CONCLUSIONS: The use of VCS is a promising alternative to hand-sewn anastomoses. It takes less time to perform a stapled anastomosis, the technique has a shorter learning period and morbidity seems to be lower when vascular anastomoses are applied with the VCS in this rabbit model.  相似文献   

16.
The achievement of patency of the microvascular anastomosis in free flap surgery is dependent on a number of factors, central to which is atraumatic handling of the vessel lumen, and intimal apposition. Initial laboratory studies demonstrating the superiority of the non-penetrating vascular closure staple (VCS - Anastoclip ?) were followed by our report in 1999 on a series of free flaps. There is still a paucity of data in the literature on the use of non-penetrating devices for microvascular anastomosis, and our review gives evidence to support the routine use of the VCS in microsurgical free flap surgery. We now report on its successful use over a thirteen year period in 819 free flap reconstructions. Our data indicates the VCS device to be as effective as sutured anastomoses in free tissue transfer surgery. There is also statistically significant data (Barnard's Exact Test) to demonstrate a higher vascular patency rate of the VCS device over sutured anastomoses when sub group analysis is performed. 'Take-back' revision rates were lower amongst flaps that employed VCS use. For arterial anastomoses, this equated to 3/654(0.05%) vs 4/170(2.4%) with hand-sewn anastomoses (p?=?0.02). Similarly, for venous anastomoses the 'take-back' revision rate was 7/661(1.1%) vs 8/165(4.8%) with hand-sewn anastomoses (p?=?0.003). Furthermore, the major advantage of the VCS is reduction in anastomosis time, from approximately 25?min per anastomosis for sutures to between five and 10?min for staples.  相似文献   

17.
Mechanism of tissue fusion in argon laser-welded vein-artery anastomoses   总被引:1,自引:0,他引:1  
The mechanism of laser vascular tissue welding remains unknown. This study compared the acute tissue response and long-term healing of sutured and laser-welded anastomoses of vein segments used to bypass ligated canine femoral arteries. For each procedure, one anastomosis was formed using running 6-0 polypropylene suture (control), and the other anastomosis was formed using argon laser tissue welding (experimental). The vein grafts were harvested at 4 (n = 2), 8 (n = 1), 12 (n = 1), and 16 (n = 2) weeks, and selected samples were evaluated by histologic examination, electron microscopy, tensile strength testing, and by measuring the formation of [3H]hydroxyproline as an index of collagen synthesis. Examination of successful laser fusions immediately after they were formed showed bonding of collagen to collagen and elastin to collagen. Follow-up evaluations showed that the precision of tissue apposition affected the rate of healing and tensile strength. Laser-welded anastomoses demonstrated a progression of healing similar to sutured repairs, with remodeling of fibrous tissue and collagen being the primary component of weld integrity. This study demonstrates that sutured and argon laser-welded vein-artery anastomoses heal comparably up to 16 weeks postoperatively, and that laser welding is a satisfactory alternative to sutured anastomoses.  相似文献   

18.
BACKGROUND: The left internal thoracic artery (LITA) is accepted as a superior graft for the left coronary system because of its better long-term patency rate than saphenous grafts. The postsurgical histomorphometric changes at the distal anastomosis of LITA grafts are not well documented. METHODS: The cellular changes within the intima of 59 LITA grafts were analyzed by light microscopy. RESULTS: Grafts implanted 1 week or less (n = 34) showed no postsurgical tissue proliferation. Of the 7 grafts implanted 1 to 8 weeks, only the suture sites exhibited intimal thickening (6 of 7 grafts, 0.08 +/- 0.07 mm). The remaining grafts (n = 18), aged 2 months to 10 years, showed significant intimal thickening at the suture sites (0.39 +/- 0.17 mm) and on the hood (0.29 +/- 0.25 mm), with variable thickening on the floor (10 of 18 left anterior descending coronary arteries, 0.11 +/- 0.12 mm). The graft body showed insignificant intimal changes (10 of 18, 0.03 +/- 0.04 mm), with mild focal atherosclerotic lesions in 2 of 18 late LITA grafts. CONCLUSIONS: Left internal thoracic artery grafts develop fibromuscular intimal hyperplasia primarily around the anastomosis. The response on the hood appears to be a hemodynamic response, secondary to that of the suture sites.  相似文献   

19.
PURPOSE: Anastomotic compliance is an important predictive factor for long-term patency of small diameter vascular reconstruction. In this experimental study we compare the compliance of continuous and interrupted sutured vascular anastomoses with those using nonpenetrating clips. METHODS: Both common carotid arteries in nine goats (average weight, 57 +/- 5.7 kg) were transected, and end-to-end anastomoses were constructed with nonpenetrating clips or polypropylene sutures. The latter were applied with both interrupted and continuous techniques. Intraluminal pressure was measured with a Millar Mikro-tip transducer, and vessel wall motion was determined with duplex ultrasound equipped with an echo-locked wall-tracking system. Diametrical compliance was determined. Environmental scanning electron microscopy was performed on explanted anastomoses. RESULTS: There was a reduction in anastomotic compliance and associated proximal and distal para-anastomotic hypercompliant zones with the use of all techniques. However, compliance loss was significantly less in those anastomoses with clips and interrupted sutures when compared with continuous suture (P <.001). Furthermore, the total compliance mismatch across anastomoses with continuous sutures was significantly greater than those with clips or interrupted sutures (P <.05). The mean time for constructing clipped anastomoses was 5.7 +/- 1.4 minutes, which was significantly less than either continuous (P <.0001) or interrupted sutures (P <.0001). Furthermore, environmental scanning electron microscopy demonstrated minimal intimal damage with good intimal apposition in the clip group. CONCLUSION: Anastomoses performed with nonpenetrating clips resulted in improved para-anastomotic compliance profiles and reduced intimal damage when compared with those with polypropylene sutures. These benefits may enhance long-term graft patency by reducing the risk of anastomotic intimal hyperplasia.  相似文献   

20.
Background and Objectives: The argon laser-assisted vascular anastomosis may solve the problems of conventional sutured anastomosis, such as vascular stenosis and arrest of growth owing to a foreign-body reaction to suture material. Study Design/Materials and Methods: Twelve argon laser-assisted vascular anastomoses, seven conventional anastomoses with interrupted sutures, and five conventional anastomoses with continuous sutures were performed in 12 young mongrel dogs. Results: Five months later, the external diameter at the anastomosis had increased 70.5% in the laser group, 67.0% in the interrupted suture group, and 22.9% in the continuous suture group. Histological examination of the laser-assisted anastomoses showed almost complete healing, with no granulomatous response around the anastomotic site. In the interrupted suture group, marked scaring and foreign body reactions were observed on the vessel wall at the site of the anastomosis. The continuous suture group showed more remarkable disorientation of the vascular layer and intimal hyperplasia than the interrupted suture group. Conclusion: Vascular anastomosis using the argon laser offers advantages over the conventional procedure in growing vessels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号