首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BACKGROUND: Viral contamination of platelet (PLT) concentrates can result in transfusion-transmitted diseases. A photochemical treatment (PCT) process with amotosalen-HCl and long-wavelength ultraviolet light (UVA), which cross-links nucleic acids, was developed to inactivate viruses and other pathogens in PLT concentrates. STUDY DESIGN AND METHODS: High titers of pathogenic or blood-borne viruses, representing 10 different families, were added to single-donor PLT concentrates containing 3.0 x 10(11) to 6.0 x 10(11) PLTs in approximately 300 mL of 35 percent plasma and 65 percent PLT additive solution (InterSol). After PCT with 150 micromol per L amotosalen and 3 J per cm(2) UVA, residual viral infectivity was assayed by sensitive cell culture or animal systems. RESULTS: Enveloped viruses were uniformly sensitive to inactivation by PCT whereas nonenveloped viruses demonstrated variable inactivation. Log reduction of enveloped viruses for cell-free HIV-1 was >6.2; for cell-associated HIV-1, >6.1; for clinical isolate HIV-1, >3.4; for clinical isolate HIV-2, >2.5; for HBV, >5.5; for HCV, >4.5; for DHBV, >6.2; for BVDV, >6.0; for HTLV-I, 4.2; for HTLV-II, 4.6; for CMV, >5.9; for WNV, >5.5; for SARS-HCoV, >5.8; and for vaccinia virus, >4.7. Log reduction of nonenveloped viruses for human adenovirus 5 was >5.2; for parvovirus B19, 3.5->5.0; for bluetongue virus, 5.6-5.9; for feline conjunctivitis virus, 1.7-2.4; and for simian adenovirus 15, 0.7-2.3. CONCLUSION: PCT inactivates a broad spectrum of pathogenic, blood-borne viruses. Inactivation of viruses in PLT concentrates with amotosalen and UVA offers the potential to prospectively prevent the majority of PLT transfusion-associated viral diseases.  相似文献   

2.
BACKGROUND: Bacterial contamination of platelet (PLT) concentrates can result in transfusion-transmitted sepsis. A photochemical treatment (PCT) process with amotosalen HCl and long-wavelength ultraviolet light (UVA), which cross-links nucleic acids, was developed to inactivate bacteria and other pathogens in PLT concentrates. STUDY DESIGN AND METHODS: High titers of pathogenic aerobic and anaerobic Gram-positive bacteria (10 species), aerobic Gram-negative bacteria (7 species), and spirochetes (2 species) were added to single-donor PLT concentrates containing 3.0 x 10(11) to 6.0 x 10(11) PLTs in approximately 300 mL of 35 percent plasma and 65 percent PLT additive solution (InterSol, Baxter Healthcare) or saline. After PCT with 150 micro mol per L amotosalen and 3 J per cm(2) UVA, residual bacterial levels were detected by sensitive microbiologic methods. RESULTS: The level of inactivation of viable bacteria was expressed as log reduction. Log reduction of Gram-positive bacteria for Staphylococcus epidermidis was > 6.6; for Staphylococcus aureus, 6.6; for Streptococcus pyogenes, > 6.8; for Listeria monocytogenes, > 6.3; for Corynebacterium minutissimum, > 6.3; for Bacillus cereus (vegetative), > 5.5; for Lactobacillus sp., > 6.4; for Bifidobacterium adolescentis, > 6.0; for Propionibacterium acnes, > 6.2; and for Clostridium perfringens, > 6.5. Log reduction of Gram-negative bacteria for Escherichia coli was > 6.4; for Serratia marcescens, > 6.7; for Klebsiella pneumoniae, > 5.6; for Pseudomonas aeruginosa, 4.5; for Salmonella choleraesuis, > 6.2; for Yersinia enterocolitica, > 5.9; and for Enterobacter cloacae, 5.9. Log reduction of spirochetes for Treponema pallidum was 6.8 to 7.0, and for Borrelia burgdorferi, > 6.9. CONCLUSION: PCT inactivates high levels of a broad spectrum of pathogenic bacteria. The inactivation of bacteria in PLT concentrates offers the potential to prospectively prevent PLT-transfusion-associated bacteremia.  相似文献   

3.
4.
BACKGROUND: A photochemical treatment (PCT) system has been developed to inactivate a broad spectrum of pathogens and white blood cells in platelet (PLT) products. The system comprises PLT additive solution (PAS III), amotosalen HCl, a compound adsorption device (CAD), a microprocessor-controlled ultraviolet A light source, and a commercially assembled system of interconnected plastic containers. STUDY DESIGN AND METHODS: A clinical prototype of the PCT system was used in a large, randomized, controlled, double-blind, Phase III clinical trial (SPRINT) that compared the efficacy and safety of PCT apheresis PLTs to untreated apheresis PLTs. The ability of multiple users was assessed in a blood center setting to perform the PCT and meet target process specifications. RESULTS: Each parameter was evaluated for 2237 to 2855 PCT PLT products. PCT requirements with respect to mean PLT dose, volume, and plasma content were met. Transfused PCT PLT products contained a mean of 3.6 x 10(11) +/- 0.7 x 10(11) PLTs. The clinical process, which included trial-specific samples, resulted in a mean PLT loss of 0.8 x 10(11) +/- 0.6 x 10(11) PLTs per product. CAD treatment effectively reduced the amotosalen concentration from a mean of 31.9 +/- 5.3 micromol per L after illumination to a mean of 0.41 +/- 0.56 micromol per L after CAD. In general, there was little variation between sites for any parameter. CONCLUSIONS: The PCT process was successfully implemented by 12 blood centers in the United States to produce PCT PLTs used in a prospective, randomized trial where therapeutic efficacy of PCT PLTs was demonstrated. Process control was achieved under blood bank operating conditions.  相似文献   

5.
6.
7.
8.
9.
核黄素联合紫外线A照射对血浆中伪狂犬病毒的灭活效果   总被引:2,自引:1,他引:2  
目的考察核黄素联合紫外线A对血浆中伪狂犬病毒的灭活效果。方法以伪狂犬病毒为模拟病毒,以Vero细胞为培养细胞,用病毒感染细胞,制备病毒增殖液;分别采用5、10、15及20J/cm2联合核黄素处理血浆,观察处理前后血浆病毒灭活的效果,筛选灭活病毒合适的紫外线剂量;将含有伪狂犬病毒血浆的样本分为实验组:采用上述筛选的紫外线强度照射联合核黄素处理;对照组1:单独采用紫外线A照射;对照组2:单独采用核黄素处理;阴性对照组:未采用紫外线照射和核黄素处理;分别在实验前后采用96孔细胞病变法,对照细胞病变效应,根据Reed-Muench公式计算病毒滴度。结果采用不同强度的紫外线联合核黄素处理血浆,紫外线强度为15及20J/cm2的灭活血浆病毒的效果明显,处理后病毒滴度分别下降4.55和4.39logs;实验组和对照组1病毒滴度分别下降4.55和4.28logs,有统计学意义(P<0.05);对照组2病毒滴度降低1.93logs,没有病毒灭活效果。结论核黄素联合紫外线可灭活血浆中伪狂犬病毒,单独紫外线照射也具有灭活血浆伪狂犬病毒的效果;而仅单独采用核黄素处理而未联合紫外线照射,对血浆中伪狂犬病毒灭活效果不明显。  相似文献   

10.
BACKGROUND: The human erythrovirus B19 (B19) is a small (18- to 26-nm) nonenveloped virus with a single-stranded DNA genome of 5.6 kb. B19 is clinically significant and is also generally resistant to pathogen inactivation methods. Photochemical treatment (PCT) with amotosalen and ultraviolet A (UVA) inactivates viruses, bacteria, and protozoa in platelets (PLTs) and plasma prepared for transfusion. In this study, the capacity of PCT to inactivate B19 in human PLT concentrates was evaluated. STUDY DESIGN AND METHODS: B19 inactivation was measured by a novel enzyme-linked immunosorbent spot (ELISPOT) erythroid progenitor cell infectivity assay and by inhibition of long-range (up to 4.3 kb) polymerase chain reaction (PCR), under conditions where the whole coding region of the viral genome was amplified. B19-infected plasma was used to test whether incubation of amotosalen with virus before PCT enhanced inactivation compared to immediate PCT. RESULTS: Inactivation of up to 5.8 log of B19 as measured by the infectivity assay, or up to 6 logs as measured by PCR inhibition can be achieved under non-limiting conditions. Inactivation efficacy was found to increase with incubation prior to UVA illumination. Without incubation prior to illumination 2.1 +0.4 log was inactivated as determined by infectivity assay. When measured by PCR inhibition, inactivation varied inversely with amplicon size. When primers that spanned the entire coding region of the B19 genome were used, maximum inhibition of PCR amplification was demonstrated. CONCLUSION: Under defined conditions, PCT with amotosalen combined with UVA light can be used to inactivate B19, a clinically significant virus that can be transmitted through blood transfusion, and heretofore has been demonstrated to be refractory to inactivation.  相似文献   

11.
BACKGROUND: This study evaluated the efficacy of photochemical treatment (PCT) with amotosalen and ultraviolet A (UVA) light to inactivate Trypanosoma cruzi in contaminated platelet (PLT) components. STUDY DESIGN AND METHODS: Fifteen pools of buffy-coat PLTs (BC-PLTs) were inoculated with approximately 5 x 10(3) to 5 x 10(5) per mL of viable T. cruzi of the G, Tulahuen (T), or Y strains. Samples from BC-PLTs were assayed for infectivity before and after PCT with 150 micromol per L amotosalen and 3 J per cm(2) UVA light. Infectivity was determined with three different methods: 1) in vitro culture to detect viable epimastigotes, 2) [(3)H]thymidine incorporation in culture, and 3) in vivo inoculation into interferon-gamma receptor (IFN-gammaR)-deficient mice. RESULTS: The in vitro assay yielded viable parasite titers of 3.9 x 10(5), 2.8 x 10(4), and 5.6 x 10(3) per mL (corresponding to 5.6, 4.4, and 3.8 logs/mL) for the Y, T, and G strains, respectively. PCT was able to inactivate all three strains of T. cruzi to below the limit of detection (10 parasites/mL) in the sensitive in vivo assay. Because 10-mL samples, each concentrated into a 1-mL sample for inoculation, were tested in the in vivo assay, log reductions achieved were greater than 5.6, greater than 4.4, and greater than 3.8 for the Y, T, and G strains of T. cruzi, respectively. CONCLUSIONS: The pathogen reduction system with amotosalen HCl and UVA demonstrated robust efficacy for inactivation of high doses of three different strains of T. cruzi and offers the potential to make the PLT supply safer.  相似文献   

12.
BACKGROUND: The INTERCEPT Blood System, a photochemical treatment (PCT) process, has been developed to inactivate pathogens in platelet concentrates. These studies evaluated the efficacy of PCT to inactivate pathogens in plasma and the effect of PCT on plasma function. STUDY DESIGN AND METHODS: Jumbo (600 mL) plasma units were inoculated with high titers of test pathogens and treated with 150 micromol per L amotosalen and 3 J per cm(2) long-wavelength ultraviolet light. The viability of each pathogen before and after treatment was measured with biological assays. Plasma function was evaluated through measurement of coagulation factors and antithrombotic protein activities. RESULTS: The levels of inactivation expressed as log-reduction were as follows: cell-free human immunodeficiency virus-1 (HIV-1), greater than 6.8; cell-associated HIV-1, greater than 6.4; human T-lymphotropic virus-I (HTLV-I), 4.5; HTLV-II, greater than 5.7; hepatitis B virus (HBV) and hepatitis C virus, greater than 4.5; duck HBV, 4.4 to 4.5; bovine viral diarrhea virus, 6.0; severe acute respiratory syndrome coronavirus, 5.5; West Nile virus, 6.8; bluetongue virus, 5.1; human adenovirus 5, 6.8; Klebsiella pneumoniae, greater than 7.4; Staphylococcus epidermidis and Yersinia enterocolitica, greater than 7.3; Treponema pallidum, greater than 5.9; Borrelia burgdorferi, greater than 10.6; Plasmodium falciparum, 6.9; Trypanosoma cruzi, greater than 5.0; and Babesia microti, greater than 5.3. Retention of coagulation factor activity after PCT was expressed as the proportion of pretreatment (baseline) activity. Retention was 72 to 73 percent of baseline fibrinogen and Factor (F)VIII activity and 78 to 98 percent for FII, FV, FVII, F IX, FX, FXI, FXIII, protein C, protein S, antithrombin, and alpha2-antiplasmin. CONCLUSION: PCT of plasma inactivated high levels of a wide range of pathogens while maintaining adequate coagulation function. PCT has the potential to reduce the risk of transfusion-transmitted diseases in patients requiring plasma transfusion support.  相似文献   

13.
14.
15.
16.
17.
BackgroundTest the ability of Mirasol Pathogen Reduction Technology (PRT, Terumo BCT, Lakewood Co, USA) treatment with riboflavin and ultraviolet light (R + UV) in reducing SARS-CoV-2 infectivity while maintaining blood product quality.Material and methodsSARS-CoV-2 strains were isolated and titrated to prepare cell free virus for plasma units infection. The units were then under treatment with Mirasol PRT. The infectious titers were determined before and after treatment with an in house microtitration assay on Vero E6 cells. Thirty-six plasma pool bags underwent PRT treatment.ResultsIn all the experiments, the measured titer following riboflavin and UV treatment was below the limit of detection of microtitration assay for all the different SARS-CoV-2 strains. Despite the high copies number detected by RT-PCR for each viral strain after treatment, viruses were completely inactivated and not able to infect VERO E6 cells.ConclusionRiboflavin and UV light treatment effectively reduced the virus titers of human plasma to the limit of detection in tissue culture, regardless of the strain. These data suggest that pathogen reduction in blood products highlight the safety of CP therapy procedures for critically ill COVID-19 patients, while maintaining blood product quality.  相似文献   

18.
19.
BACKGROUND: It is estimated that approximately 300,000 neonates undergo transfusions annually. The neonatal immune system is immature, making such patients more susceptible to the effects associated with transfusion-transmitted bacteria, viruses, protozoa, and white blood cells (WBCs). The INTERCEPT Blood System is a photochemical process (PCT) utilizing amotosalen and long-wavelength ultraviolet to inactivate pathogens and WBCs in both platelet (PLT) and plasma components for transfusion. A series of clinical studies has shown PCT PLTs and PCT plasma to be safe and effective for transfusion in adults and pediatric patients. Because clinical studies in neonates are technically difficult and ethically challenging, preclinical toxicologic studies were conducted in neonatal rats to evaluate the safety of PCT blood components for neonates.
STUDY DESIGN AND METHODS: This study examined daily intravenous administration to neonatal rats of amotosalen in 35 percent:65 percent plasma:InterSol from 1 µg per kg per day (representing 1-unit transfusion) to 457 µg per kg per day (representing multiple transfusions) from Postnatal Day 4 (PND4) to PND31. Rats were observed for viability, clinical signs, and body weights until PND31 and then subjected to pathology evaluation. Hematology, clinical chemistry, and urinalysis data were also collected on PND31. Toxicokinetic parameters were evaluated on PND4 and PND31.
RESULTS: There were no amotosalen-related effects on clinical signs, body weight, hematology, clinical chemistry, urinalysis, gross pathology, or histopathology, despite the exposure of neonatal rats to amotosalen concentrations as high as approximately 48 times the standard exposure in adult patients.
CONCLUSION: This study demonstrates the safety of PCT for transfusion in neonatal rats and augments data from other studies and clinical use supporting the use of PCT in neonatal patients.  相似文献   

20.
BACKGROUND: A photochemical treatment (PCT) method utilizing a novel psoralen, amotosalen HCl, with ultraviolet A illumination has been developed to inactivate viruses, bacteria, protozoa, and white blood cells in platelet (PLT) concentrates. A randomized, controlled, double-blind, Phase III trial (SPRINT) evaluated hemostatic efficacy and safety of PCT apheresis PLTs compared to untreated conventional (control) apheresis PLTs in 645 thrombocytopenic oncology patients requiring PLT transfusion support. Hemostatic equivalency was demonstrated. The proportion of patients with Grade 2 bleeding was not inferior for PCT PLTs. STUDY DESIGN AND METHODS: To further assess the safety of PCT PLTs, the adverse event (AE) profile of PCT PLTs transfused in the SPRINT trial is reported. Safety assessments included transfusion reactions, AEs, and deaths in patients treated with PCT or control PLTs in the SPRINT trial. RESULTS: A total of 4719 study PLT transfusions were given (2678 PCT and 2041 control). Transfusion reactions were significantly fewer following transfusion of PCT than control PLTs (3.0% vs. 4.1%; p = 0.02). Overall AEs (99.7% PCT vs. 98.2% control), Grade 3 or 4 AEs (79% PCT vs. 79% control), thrombotic AEs (3.8% PCT vs. 3.7% control), and deaths (3.5% PCT vs. 5.2% control) were comparable between treatment groups. Minor hemorrhagic AEs (petechiae [39% PCT vs. 29% control; p < 0.01] and fecal occult blood [33% PCT vs. 25% control; p = 0.03]) and skin rashes (56% PCT vs. 42% control; p < 0.001) were significantly more frequent in the PCT group. CONCLUSION: The overall safety profile of PCT PLTs was comparable to untreated PLTs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号