首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Rodent enamel microstructure has been extensively investigated, primarily on the basis of 2D electronic microscopy data. The nature and dynamics of the ameloblasts (the enamel-secreting cells) have also been well studied. However, critical issues still remain surrounding exactly how the ameloblasts produce the astonishing microstructural complexity of enamel, and how this subtle architecture evolved through time. In this article, we used a new methodology based on confocal laser microscopy to reconstruct the enamel microstructure of rodent incisors in three dimensions (3D) with the ameloblasts in situ. We proposed interpretations regarding the possible relationships between the workings of the ameloblasts and the resulting enamel prisms, especially how the phenomenon of decussation is generated. Finally, we were able to represent the two main types of modern rodent incisor microstructures (uniserial and multiserial decussations), as a set of parameters that have been entered into the 3D enamel simulation software Simulenam to generate 3D models that can be digitally manipulated. Associating 2D data of incisor enamel microstructure of fossil rodents and Simulenam, it was then possible to better understand how the various decussation parameters evolved through time and gave rise to the two modern microstructure types from the same ancestral type (pauciserial). This study also confirmed that rodent and artiodactyl enamel do not share the same mechanism of decussation formation. Anat Rec, 302:1195–1209, 2019. © 2018 Wiley Periodicals, Inc.  相似文献   

2.
The Joint Photographic Experts Group (JPEG) standard format is one of the most widely used in image compression technologies. More recently, JPEG2000 format has emerged as a state-of-the-art technology that provides substantial improvements in picture quality at higher compression ratios. However, there has been no attempt to date to determine which of the two compression formats produces less variability in the automated evaluation of immunohistochemically stained digital images in agreement with their compression rates and complexity degrees. The evaluation of Ki67 and FOXP3 immunohistochemical nuclear markers was performed in a total of 329 digital images: 47 were captured in uncompressed Tagged Image File Format (TIFF), 141 were converted to three JPEG compressed formats (47 each with 1:3, 1:23 and 1:46 compression) and 141 were converted to three JPEG2000 compressed formats (47 each with 1:3, 1:23 and 1:46 compression). The count differences between images in TIFF versus JPEG formats were compared with those obtained between images in TIFF versus JPEG2000 formats at the three levels of compression. It was found that, using JPEG2000 compression, the results of the stained nuclei count are close enough to the results obtained with uncompressed images, especially in highly complex images at minimum and medium compression. Otherwise, in images of low complexity, JPEG and JPEG2000 had similar count efficiency to that of the original TIFF images at all compression levels. These data suggest that JPEG2000 could give rise to an efficient means of storage, reducing file size and storage capacity, without compromise on the immunohistochemical analytical quality.  相似文献   

3.
INTRODUCTION   In the treatmentof labial teeth by light-cure composite resin,before acid-etchingthe artificial grinding method isusually adopted to thin the enamel supperficial layerso as to enhance the acid-etching effect and to improve the fixation of…  相似文献   

4.
The aim of the study was to evaluate the effect of two lossy image compression methods on fractal dimension (FD) calculation. Ten periapical images of the posterior teeth with no restorations or previous root canal therapy were obtained using storage phosphor plates and were saved in TIF format. Then, all images were compressed with lossy JPEG and JPEG2000 compression methods at five compression levels, i.e., 90, 70, 50, 30, and 10. Compressed file sizes from all images and compression ratios were calculated. On each image, two regions of interest (ROIs) containing healthy trabecular bone in the posterior periapical area were selected. The FD of each ROI on the original and compressed images was calculated using differential box counting method. Both image compression and analysis were performed by a public domain software. Altogether, the FD of 220 ROIs was calculated. FDs were compared using ANOVA and Dunnett tests. The FD decreased gradually with compression level. A statistically significant decrease of the FD values was found for JPEG 10, JPEG2000 10, and JPEG2000 30 compression levels (p < 0.05). At comparable file sizes, the JPEG induced a smaller FD difference. In conclusion, lossy compressed images with appropriate compression level may be used for FD calculation.  相似文献   

5.
This study aims to compare the integrity and reproducibility of measurements created from uncompressed and compressed digital images in order to implement compliance with 21 CFR Part 11 for image analysis studies executed using 21 CFR Part 58 compliant capture systems. Images of a 400-mesh electron microscope grid and H&E stained rat liver tissue were captured on an upright microscope with digital camera using commercially available analysis software. Digital images were stored as either uncompressed TIFFs or in one of five different levels of JPEG compression. The grid images were analyzed with automatic detection of bright objects while the liver images were segmented using color cube-based morphometry techniques, respectively, using commercially-available image analysis software. When comparing the feature-extracted measurements from the TIFF uncompressed to the JPEG compressed images, the data suggest that JPEG compression does not alter the accuracy or reliability to reproduce individual data point measurements in all but the highest compression levels. There is, however, discordance if the initial measure was obtained with a TIFF format and subsequently saved as one of the JPEG levels, suggesting that the use of compression must precede feature extraction. It is a common practice in software packages to work with TIFF uncompressed images. However, this study suggests that the use of JPEG compression as part of the analysis work flow was an acceptable practice for these images and features. Investigators applying image file compression to other organ images will need to validate the utility of image compression in their work flow. A procedure to digitally acquire and JPEG compress images prior to image analysis has the potential to reduce file archiving demands without compromising reproducibility of data.  相似文献   

6.
《Journal of anatomy》2017,230(2):272-281
The Havers‐Halberg Oscillation (HHO) hypothesis links evidence for the timing of a biorhythm retained in permanent tooth enamel (Retzius periodicity) to adult body mass and life history traits across mammals. Potentially, these links provide a way to access life history of fossil species from teeth. Recently we assessed intra‐specific predictions of the HHO on human children. We reported Retzius periodicity (RP) corresponded with enamel thickness, and cusp formation time, when calculated from isolated deciduous teeth. We proposed the biorhythm might not remain constant within an individual. Here, we test our findings. RP is compared between deciduous second and permanent first molars within the maxillae of four human children. Following this, we report the first RPs for deciduous teeth from modern great apes (= 4), and compare these with new data for permanent teeth (= 18) from these species, as well as with previously published values. We also explore RP in teeth that retain hypoplastic defects. Results show RP changed within the maxilla of each child, from thinner to thicker enameled molars, and from one side of a hypoplastic defect to the other. When considered alongside correlations between RP and cusp formation time, these observations provide further evidence that RP is associated with enamel growth processes and does not always remain constant within an individual. RP of 5 days for great ape deciduous teeth lay below the lowermost range of those from permanent teeth of modern orangutan and gorilla, and within the lowermost range of RPs from chimpanzee permanent teeth. Our data suggest associations between RP and enamel growth processes of humans might extend to great apes. These findings provide a new framework from which to develop the HHO hypothesis, which can incorporate enamel growth along with other physiological systems. Applications of the HHO to fossil teeth should avoid transferring RP between deciduous and permanent enamel, or including hypoplastic teeth.  相似文献   

7.
Evidence of a periodic biorhythm is retained in tooth enamel in the form of Retzius lines. The periodicity of Retzius lines (RP) correlates with body mass and the scheduling of life history events when compared between some mammalian species. The correlation has led to the development of the inter‐specific Havers–Halberg oscillation (HHO) hypothesis, which holds great potential for studying aspects of a fossil species biology from teeth. Yet, our understanding of if, or how, the HHO relates to human skeletal growth is limited. The goal here is to explore associations between the biorhythm and two hard tissues that form at different times during human ontogeny, within the context of the HHO. First, we investigate the relationship of RP to permanent molar enamel thickness and the underlying daily rate that ameloblasts secrete enamel during childhood. Following this, we develop preliminary research conducted on small samples of adult human bone by testing associations between RP, adult femoral length (as a proxy for attained adult stature) and cortical osteocyte lacunae density (as a proxy for the rate of osteocyte proliferation). Results reveal RP is positively correlated with enamel thickness, negatively correlated with femoral length, but weakly associated with the rate of enamel secretion and osteocyte proliferation. These new data imply that a slower biorhythm predicts thicker enamel for children but shorter stature for adults. Our results develop the intra‐specific HHO hypothesis suggesting that there is a common underlying systemic biorhythm that has a role in the final products of human enamel and bone growth.  相似文献   

8.
There are unresolved clinical problems that require the provision of accurate 3-D images of tissue structures such as teeth. In particular, measurements of dental enamel thickness are necessary to quantify problems associated with enamel erosion, yet currently there is no nondestructive method to obtain this information. We present a method that relies on the use of pulsed terahertz radiation to gain 3-D information from dental tissues. We discuss results from 14 samples and demonstrate that we can reliably and accurately quantify enamel thickness. We show that in a series of 22 surfaces, we can image pertinent subsurface features 91% of the time. Example images are shown where structures in teeth at depth are rendered accurate to within 10 microm. We discuss issues that arise using this imaging method and propose ways in which it could be used in clinical practice.  相似文献   

9.
An ultrathin scanning fiber endoscope, originally developed for cancer diagnosis, was used to image dental occlusal surfaces as well as shallow artificially induced enamel erosions from human extracted teeth (n=40). Enhanced image resolution of occlusal surfaces was obtained using a short-wavelength 405-nm illumination laser. In addition, artificial erosions of varying depths were also imaged with 405-, 404-, 532-, and 635-nm illumination lasers. Laser-induced autofluorescence images of the teeth using 405-nm illumination were also obtained. Contrast between sound and eroded enamel was quantitatively computed for each imaging modality. For shallow erosions, the image contrast with respect to sound enamel was greatest for the 405-nm reflected image. It was also determined that the increased contrast was in large part due to volume scattering with a smaller component from surface scattering. Furthermore, images obtained with a shallow penetration depth illumination laser (405 nm) provided the greatest detail of surface enamel topography since the reflected light does not contain contributions from light reflected from greater depths within the enamel tissue. Multilayered Monte Carlo simulations were also performed to confirm the experimental results.  相似文献   

10.
11.
The aim of this paper was to quantitatively assess caries changes of teeth by using digital image analysis. Digital images of stained sections of crowns of teeth were acquired with a computer-assisted light microscope. In each image, spots representing the main and total demineralization of enamel were segmented to determine their area. The area of total demineralization was significantly different between premolars with sealed fissures and unprotected premolars as indicated by the Mann–Whitney test. Fissures on occlusal surfaces of premolars were characterized by their width, height, and distance from the bottom of the fissure to the enamel–dentin junction. This distance was also significantly different between protected and unprotected teeth. The results of our in vitro studies of enamel lesions allow us to plan an effective diagnosis, prophylaxis, and treatment of early caries changes in in vivo conditions. © 2003 Biomedical Engineering Society. PAC2003: 8764Rr, 8757Ra, 8757Nk, 8780Pa  相似文献   

12.
The 2D arrangement of rows of enamel rods with alternating (decussating) tilt angles across the thickness of the inner layer in rat and mouse incisor enamel is well known and assumed to occur in a uniform and repetitive pattern. Some irregularities in the arrangement of rows have been reported, but no detailed investigation of row structure across the entire inner enamel layer currently exists. This investigation was undertaken to determine if the global row pattern in mouse mandibular incisor enamel is predominately regular in nature with only occasional anomalies or if rows of enamel rods have more spatial complexity than previously suspected. The data from this investigation indicate that rows of enamel rods are highly variable in length and have complex transverse arrangements across the width and thickness of the inner enamel layer. The majority of rows are short or medium in length, with 87% having < 100 rods per row. The remaining 13% are long rows (with 100–233 rods per row) that contain 46% of all enamel rods seen in transverse sections. Variable numbers of rows were associated with the lateral, central and mesial regions of the enamel layer. Each region contained different ratios of short, medium and long rows. A variety of relationships was found along the transverse length of rows in each region, including uniform associations of alternating rod tilts between neighboring rows, and instances where two rows having the same rod tilt were paired for variable distances then moved apart to accommodate rows of opposite tilt. Sometimes a row appeared to branch into two rows with the same tilt, or conversely where two rows merged into one row depending upon the mesial‐to‐lateral direction in which the row was viewed. Some rows showed both pairing and branching/merging along their length. These tended to be among the longest rows identified, and they often crossed the central region with extensions into the lateral and mesial regions. The most frequent row arrangement was a row of petite length nestled at the side of another row having the same rod tilt (30% of all rows). These were termed ‘focal stacks’ and may relate to the evolution of uniserial rat and mouse incisor enamel from a multilayered ancestor. The mesial and lateral endpoints of rows also showed complex arrangements with the dentinoenamel junction (DEJ), the inner enamel layer itself, and the boundary area to the outer enamel layer. It was concluded that the diversity in row lengths and various spatial arrangements both within and between rows across the transverse plane provides a method to interlock the enamel layer across each region and keep the enamel layer compact relative to the curving DEJ surface. The uniserial pattern for rows in mouse mandibular incisors is not uniform, but diverse and very complex.  相似文献   

13.
BACKGROUND: This paper concentrates on strategies for less costly handling of medical images. Aspects of digitization using conventional digital cameras, lossy compression with good diagnostic quality, and visualization through less costly monitors are discussed. METHOD: For digitization of film-based media, subjective evaluation of the suitability of digital cameras as an alternative to the digitizer was undertaken. To save on storage, bandwidth and transmission time, the acceptable degree of compression with diagnostically no loss of important data was studied through randomized double-blind tests of the subjective image quality when compression noise was kept lower than the inherent noise. A diagnostic experiment was undertaken to evaluate normal low cost computer monitors as viable viewing displays for clinicians. RESULTS: The results show that conventional digital camera images of X-ray images were diagnostically similar to the expensive digitizer. Lossy compression, when used moderately with the imaging noise to compression noise ratio (ICR) greater than four, can bring about image improvement with better diagnostic quality than the original image. Statistical analysis shows that there is no diagnostic difference between expensive high quality monitors and conventional computer monitors. CONCLUSION: The results presented show good potential in implementing the proposed strategies to promote widespread cost-effective telemedicine and digital medical environments.  相似文献   

14.
This presentation focuses on the quantitative comparison of three lossy compression methods applied to a variety of 12-bit medical images. One Joint Photographic Exports Group (JPEG) and two wavelet algorithms were used on a population of 60 images. The medical images were obtained in Digital Imaging and Communications in Medicine (DICOM) file format and ranged in matrix size from 256 × 256 (magnetic resonance [MR]) to 2,560 × 2,048 (computed radiography [CR], digital radiography [DR], etc). The algorithms were applied to each image at multiple levels of compression such that comparable compressed file sizes were obtained at each level. Each compressed image was then decompressed and quantitative analysis was performed to compare each compressed-thendecompressed image with its corresponding original image. The statistical measures computed were sum of absolute differences, sum of squared differences, and peak signal-to-noise ratio (PSNR). Our results verify other research studies which show that wavelet compression yields better compression quality at constant compressed file sizes compared with JPEG. The DICOM standard does not yet include wavelet as a recognized lossy compression standard. For implementers and users to adopt wavelet technology as part of their image management and communication installations, there has to be significant differences in quality and compressibility compared with JPEG to justify expensive software licenses and the introduction of proprietary elements in the standard. Our study shows that different wavelet implementations vary in their capacity to differentiate themselves from the old, established lossy JPEG.  相似文献   

15.
Enamel bond strength is an important factor in restorative dentistry and crucially depends on the enamel roughness. To increase roughness, different etching procedures are employed and profilometric estimations, with probe profilometers, including atomic force microscopy (AFM), have been made. However, no correlation between roughness and bond strength has been found. To search for a possible error source leading to the underestimation of enamel roughness when utilizing probe profilometers, the authors compared scanning electron microscopy and AFM images of acid-etched tooth enamel. The results showed that AFM imaging cannot correctly depict the acid-etched enamel surface, because of the high steepness of the enamel crystallites and the generation of convolute images. This leads to a large underestimation of the profilometric parameters measured with AFM, or other profilometers, on acid-etched tooth enamel surfaces.  相似文献   

16.
Treatment of periodontitis which involves the furcation area of molar teeth has always been a challenge. Sixty extracted human molar teeth were used for an anatomic study to clarify the possible morphologic factors which may affect the diagnosis, prognosis, and clinical management of periodontally involved teeth. Teeth were embedded in methylmethacrylate and cut in 70 μm cross sections from the cementoenamel junction to the apex. Cervical enamel projection, root and root trunk lengths, root proximities as well as depths of root concavities coronally, apically, and at the furcation roof were measured. Cervical enamel projections were observed in 30% of the teeth examined. The shortest root trunk was found at the buccal aspect of mandibular first molars, permitting furcation involvement at early stages of periodontal disease. The most apically located furcation was found at the distal site of maxillary first molars. Furcation roofs showed severe concavities and complex cementum morphology. Teeth exhibiting cervical enamel projection were found to have deeper root concavities compared to teeth without cervical enamel projection and mesial roots of mandibular molars possessed greater furcal concavities than distal roots. The presence of root concavities complicates the diagnosis of furcation involvement and restricts access of periodontal instruments, resulting in incomplete treatment. Furcation anatomy may also influence the long-term prognosis of the teeth by favoring the retention of bacterial deposits and making oral hygiene procedures almost impossible. The present study shows that knowledge of a tooth's unique anatomic characteristics is a prerequisite for effective periodontal therapy. Clin. Anat. 11:177–186, 1998. © 1998 Wiley-Liss, Inc.  相似文献   

17.
Enamel formation front (EFF) angles represent the leading edge of enamel matrix secretion at particular points in time. These angles are influenced by rates of enamel extension (the rates at which tooth crowns grow in height), rates of enamel matrix secretion and the angles that prisms make with the enamel‐dentine junction. Previous research suggests, but has not yet established, that these angles reflect aspects of primate biology related to their pace of growth and development, most notably brain and body size. The present study tested this possibility on histological sections using phylogenetically‐controlled and Bonferroni‐corrected analyses spanning a broad taxonomic range. Ten species were represented in the analysis of anterior teeth; 17 in the analysis of posterior (postcanine) teeth (with varying sample sizes). Also, tested was the relationship of EFF angles to striae of Retzius periodicity (long period growth rhythms in enamel) and degree of folivory, as both factors are related to primate developmental rates. Finally, several analyses were conducted to investigate whether tooth size (operationalized as EDJ length) might mediate these relationships. Central results are as follows: (1) Relationships between EFF angles and brain weight (anterior teeth) and between EFF angles and body mass (anterior and posterior teeth) are statistically significant and (2) Mid‐crown EFF angles are not statistically significantly related to EDJ lengths. These results suggest that tooth size does not mediate relationships between EFF angles and brain weight/body mass and are discussed with respect to underlying enamel growth variables (especially rates of enamel extension and secretion). Anat Rec, 2017. © 2017 Wiley Periodicals, Inc. Anat Rec, 301:125–139, 2018. © 2017 Wiley Periodicals, Inc.  相似文献   

18.
目的 通过对早期自然龋变光学相干断层成像(OCT)图像进行定量分析,寻找适于光学相干断层成像技术检测早期龋的定量参数指标.方法 选取D0期、D1期和D2期自然发生釉质龋双尖牙标本各3颗,利用光学相干断层成像分别对上述不同程度早期釉质龋人离体牙进行扫描,并以龋变区域(目标区域)平均灰度值与正常区域(背景区域)平均灰度之比...  相似文献   

19.
Efficient data compression is essential for practical daily operation of computed radiography (CR) systems. In this study the clinical applicability of type III irreversible high data compression using an FCR 9501 chest unit (Fuji Photo Film, Tokyo, Japan) was evaluated. Sixty-eight normal and 93 various abnormal cases, with an additional 15 cases of lung cancers with solitary lung nodules, were selected from the file. A pair of hard copies of original images and images reconstructed using type III compression was made for each case. Six radiologists evaluated the image quality by visual rating and receiver operating characteristic (ROC) curve analysis. For all five anatomic regions of normal cases, “original equal to compressed” was the most common response, followed by “original significantly better than compressed.” When abnormal cases were evaluated for diagnostic information, there was no significant difference between the compressed and original images. ROC curve analysis on lung nodules with lung cancer showed no significant difference between the two. Compressed CR images using the type III irreversible technique are clinically applicable and acceptable despite slight degradation of image quality.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏