1.
The Amplatzer duct occluder: experience in 209 patients   总被引:56,自引:0,他引:56  
OBJECTIVES: The aim of the study was to assess the safety and efficacy of the Amplatzer ductal occluder (ADO) in transcatheter occlusion of patent ductus arteriosus (PDA). BACKGROUND: Transcatheter closure of small to moderate sized PDAs is an established procedure. The ADO is a self-expandable device with a number of salutary features, notably its retrievability, ease of delivery via small 5F to 7F catheters and a range of sizes suitable even for the larger PDAs. METHODS: Between November 1997 and August 1999, the ADO was successfully implanted in 205 of 209 patients with PDA. The inclusion criteria for this device occlusion method were patients with clinical and echocardiographic features of moderate to large PDA, weighing > or =3.5 kg as well as asymptomatic adolescents and adults with PDA measuring > or =5.0 mm on two-dimensional (2D) echocardiogram. Occlusion was achieved via the antegrade venous approach. Follow-up evaluations were performed with 2D echocardiogram, color-flow mapping and Doppler measurement of the descending aorta and left pulmonary artery velocity at 24 h and 1, 3, 6 and 12 months after implantation. RESULTS: Two hundred and five patients had successful PDA occlusion using this device. The patients were between two months and 50 years (median 1.9) and weighed between 3.4 kg and 63.2 (median 8.4). Infants made up 26% of the total patients. The PDA measured from 1.8 to 12.5 mm (mean 4.9) at the narrowest diameter. Forty-four percent of patients achieved immediate complete occlusion. On color Doppler the closure rates at 24 h and 1 month after implant were 66% and 97%, respectively. At 6 and 12 months all except one patient attained complete occlusion. Device embolization occurred in three patients; in two this was spontaneous, and in the other it was due to catheter manipulation during postimplant hemodynamic measurement. Mild aortic narrowing was seen in an infant. CONCLUSIONS: Patent ductus arteriosus occlusion using ADO is safe and efficacious. It is particularly useful in symptomatic infants and small children with relatively large PDA. Embolization can be minimized by selection of appropriate sized devices, and caution should be exercised in infants <5 kg.  相似文献   

2.
Objectives: The present study evaluates two transcatheter closure strategies utilized at a single center and makes recommendations for device selection when occluding the patent ductus arteriosus. Background: A variety of devices are available for transcatheter closure of the patent ductus arteriosus (PDA) but no guidelines exist to guide operator device choice. Methods: A total of 132 patients underwent attempted transcatheter PDA closure utilizing one of two consecutive closure strategies between January 2000 and June 2005. Strategy A (n = 64; January 2000–May 2003) utilized Gianturco coils only. Strategy B (n = 68; June 2003–June 2005) utilized a single Gianturco coil for the PDA with a minimal diameter ≤1 mm (n = 28) or an Amplatzer Duct Occluder (ADO) if the PDA diameter exceeded 1 mm (n = 40). Success was defined as complete occlusion on a follow up echocardiogram. Results: 58 of 64 (90.6%) patients treated utilizing strategy A had successful coil implantation. 68 of 68 (100%) patients treated utilizing strategy B had successful coil/device implantation. At follow up echocardiography, 32 of 44 (72.7%) strategy A patients had complete ductal closure, as compared with 57 of 58 (98.3%) strategy B patients (P < 0.0001). Stepwise logistic regression analysis identified closure strategy as the most powerful predictor of procedural success (OR = 85.9; CI 5.6–9.99). Conclusions: A transcatheter PDA closure strategy consisting of a single Gianturco coil for PDA ≤ 1 mm or an ADO for larger sized PDA (strategy B) achieves superior outcomes compared to the use of coils alone. © 2008 Wiley‐Liss, Inc.  相似文献   

3.
The purpose of this article is to present the immediate and short-term results of the international registry of transcatheter closure of patent ductus arteriosus (PDA) using the Amplatzer duct occluder (ADO). Three hundred sixteen patients (221 females) in various centers with clinical and/or echocardiographic evidence of PDA underwent an attempt of catheter closure at a median age of 2.1 years and median weight of 10.7 kg. The median Qp/Qs ratio was 2.3, the median length of the PDA was 6.7 mm and the median diameter of the PDA at its narrowest point (usually the pulmonic end) was 3.8 mm. Immediately after closure and by angiography, the PDA was completely closed in 177/311 patients (56%) and within 24 hr the complete closure rate increased to 76% (235/308). Complications were encountered in 15 patients, including 1 major complication due to device embolization and subsequent death, 6 moderate complications, and 8 minor complications. The median fluoroscopy time was 12 min and the median total procedure time was 70 min. One hundred fourteen patients reached the 6-month follow-up. Color Doppler echocardiography demonstrated complete closure in 109 patients (94.6%). Thirty-eight patients reached the 1-year follow-up mark. There was complete closure in 100% of the patients as documented by color Doppler echocardiography. So far there has been no episodes of delayed device migration, endocarditis, thromboembolism, and wire fracture or device disruption. We conclude that the ADO is safe and effective in most patients with PDA up to a diameter of 10.6 mm. Further clinical trials are underway to assess its long-term safety and efficacy.  相似文献   

4.
Objectives. The aim of this study was to assess the immediate and short-term results of anterograde catheter closure of a moderate- to large-sized patent ductus arteriosus (PDA) using the new self-expandable, respositionable Amplatzer duct occluder (ADO) device.Background. Transcatheter closure of a PDA using devices or coils is technically challenging and may be accompanied by a 38% incidence of residual shunts.Methods. Twenty-four patients (6 male, 18 female) underwent attempted transcatheter closure of a PDA using the ADO at a median age of 3.8 years (range 0.4 to 48) and a median weight of 15.5 kg (range 6 to 70). The mean PDA diameter at its narrowest segment was 3.7 ± 1.5 mm. A 6F long sheath was used for delivery of the ADO. Follow-up evaluation was performed with color flow mapping of the main pulmonary artery within 24 h and at 1 and 3 months after closure.Results. Twenty three of the 24 patients had successful device placement. Angiography showed that 7 patients had complete immediate closure, 14 had a trace shunt (foaming through the device with no jet), and 2 had a small residual shunt (with a jet). Within 24 h, color Doppler revealed complete closure in all patients. The unsuccessful attempt was during an initial trial with a prototype that has been modified. The median fluoroscopy time was 13.5 min (range 6.3 to 47). All patients were discharged home the next day. There were no complications. Of the 23 patients, 21 completed the 1-month follow-up, all (95% confidence interval [CI] 86% to 100%) with complete closure, and 18 of 23 patients completed the 3-month follow-up, also all (95% CI 83% to 100%) with complete closure.Conclusions. Anterograde transcatheter closure using the new ADO is an effective therapy for patients with a PDA diameter up to 6 mm. Further clinical trials are underway.  相似文献   

5.
Background : Reduced left lung perfusion has been described after transcatheter closure of the patent ductus arteriosus (PDA) with several prostheses. Although the Amplatzer ductal occluder (ADO) device is currently the most widely used occluder for closure of large‐sized PDAs, the potential consequences of flow distribution to the lungs of this device have not been completely clarified. We evaluated lung perfusion following occlusion of PDA with the ADO device. Methods : Forty‐seven patients underwent successful transcatheter PDA occlusion using the ADO device were included in this study. Lung perfusion scans were performed 6 months after the procedure. Results : Decreased perfusion to the left lung (defined as < 40% of total lung flow) was observed in 17 patients (36%), 5 of whom were low‐weight symptomatic infants. Ductal ampulla length was significantly shorter and minimal ductal diameter to ampulla diameter ratio was significantly higher in patients with decreased left lung perfusion and correlated well with left lung perfusion values (r = 0.516 and r = ?0.501, respectively). A cut‐off value of ≤5.8 mm for the ductal ampulla length and ≥1.9 for ampulla diameter to ampulla length ratio showed high sensitivity and specificity for reduced lung perfusion. Conclusions : The incidence of abnormal left lung perfusion is high 6 months after transcatheter closure of PDA with the ADO, more likely in the low weight symptomatic infants and in patients with a short duct or a relatively shallow duct having abrupt narrowing of a large ampulla. © 2010 Wiley‐Liss, Inc.  相似文献   

6.
目的评价Amplatzer封堵器治疗动脉导管未闭(PDA)合并重度肺动脉高压(SPH)的初步疗效.方法对12例(女9例,男3例)PDA合并SPH患者实施封堵治疗.其中10例采用Amplatzer动脉导管未闭封堵器,2例采用Amplatzer房间隔缺损封堵器.结果全组12例PDA封堵器均放置成功.11例PDA封堵后30分至1小时肺动脉收缩压、肺动脉平均压均明显降低.1例封堵术后即刻肺动脉压无变化.术后36小时彩色多普勒估测肺动脉压明显下降,封堵术后30分降主动脉造影,无残余分流9例,微量残余分流2例,少量残余分流1例.全组术后24~48小时彩色多普勒检查,动脉水平左向右分流均完全消失.无重要并发症发生.随访1~24个月(平均8个月),患者症状改善,11例心脏缩小,无1例发生再通.结论采用Amplatzer法封堵治疗PDA合并SPH,近期疗效满意.  相似文献   

7.

Aim

To assess the challenges, feasibility, and efficacy of device closure of patent ductus arteriosus (PDA) in small children weighing ⩽10 kg for different types of devices used in an initial experience at Sohag University hospital.

Methods

Between March 2011 and September 2014, 91 patients with PDA underwent transcatheter closure in our institute, among whom 54 weighed ⩽10 kg. All of these patients underwent transcatheter closure of PDA using either a Cook Detachable Coil, PFM Nit-Occlud, or Amplatzer duct occluder. A retrospective review of the treatment results and adverse events was performed.

Results

Successful device placement was achieved in 53/54 small children (98.1%). The median minimum PDA diameter was 2.4 mm [interquartile range (IQR, 1.8–3.5 mm), median weight 8 kg (IQR, 7–10 kg), and median age 10 months (IQR, 8–17 months)]. Mild aortic obstruction occurred in one case (1.9%), as the device became displaced towards the aorta after release. The device embolized in one case (1.9%) and no retrieval attempt was made. Five cases (9.3%) had minor vascular complications.

Conclusion

With the current availability of devices for PDA closure, transcatheter closure of PDA is considered safe and efficacious in small children weighing ⩽10 kg with good mid-term outcome. The procedure had a low rate of high-severity adverse events even with the initial experience of the catheterization laboratory.  相似文献   

8.
Between May 1997 and June 2000, 69 patients, ages 0.1 to 34 years, underwent attempted anterograde transcatheter closure of a patent ductus arteriosus (PDA) using the Amplatzer Duct Occluder (ADO). The ADO is a cone-shaped, self-centering, and repositionable occluder made of nitinol wire mesh. A 5Fr to 7Fr sheath was used for the delivery of the device. The mean PDA diameter (at the pulmonary end) was 4.6 +/- 1.9 mm (range 1 mm-8.5 mm). Sixty-seven of the 69 patients had successful device placement. The mean ADO smallest diameter was 6.9 +/- 1.8 mm (range 4 mm-12 mm). Complete angiographic closure occurred in 62 (92.5%) of 67 patients (95% confidence interval, 88.22%-98.77%). In five patients, there was a trivial residual shunt immediately after the procedure. At 24 hours, color Doppler flow imaging revealed complete closure in all 67 (100%) patients. The unsuccessful attempts occurred in two patients with a small, 1-mm diameter native PDA and residual PDA after surgical occlusion. Fluoroscopy time was 7.6 +/- 1.8 minutes (4 min-18 min). No complications were observed. At a median follow-up of 1.5 years (range 0.25 to 3.2 years), all patients had complete closure without complications. We conclude that transcatheter closure using the ADO is a highly effective and safe treatment for most patients with PDA.  相似文献   

9.
Background: Several devices such as coils and Amplatzer duct occluder (ADO) are used for catheter closure of patent arterial ducts (PDA). These carry a high success rate but residual shunts, suboptimal device orientation, and technical problems are encountered. The Amplatzer duct occluder II (ADO II) is designed to address these limitations. Objectives: To evaluate the technical features of the new ADO II device for PDA closure and document the immediate/early closure rate, complications and device behavior during implantation. Methods: Prospective, two center study from February 2008 to January 2009. Twenty‐seven patients (18 females) received the ADO II. The median age was 22 months (range: 7 months–68 years) and the median weight was 11.7 kg (range: 6.9–108). The median PDA diameter was 2.6 mm (range: 1–4.4). The approach was arterial in 13 and venous in 14 patients. Follow‐up included echocardiography at 1 day and 1 month postimplantation. Results: All implantations were technically successful with immediate complete angiographic closure in 21 and trivial contrast flow in six patients. The median procedure time was 43 min (range: 15–82) and the fluoroscopy time was 6 min (range: 2.2–26.5). Echocardiography confirmed no residual shunts on the following day. There were no complications. Conclusion: The new ADO II is a versatile and very effective device for closure of PDAs of various shapes, lengths, and up to diameters of 5.5 mm. The disc articulations, high early closure rate, arterial or venous approach options, and small diameter delivery catheter are all beneficial features. © 2009 Wiley‐Liss, Inc.  相似文献   

10.
Background : Over the past three decades, transcatheter occlusion of patent ductus arteriosus (PDA) has evolved to be the procedure of choice. Gianturco and Flipper coils are the most commonly used coils in the United States for closure of small and moderate size PDAs. For larger PDAs, interventionalists in the United States commonly use the Amplatzer Duct Occluder (ADO) and those in Europe use the ADO or the Nit‐Occlud Coils (NOC). A comparison between Gianturco coils, Flipper coils, ADO, and NOC has never been made. Objective : To compare the success and complication rate associated with the four different devices used for transcatheter closure of PDA. Success was defined as complete closure of PDA with absence of a residual shunt (R.S.) at six months follow‐up. Methods : Two institutions collaborated in combining their data to evaluate the results of transcatheter closure of PDA. Results : Totally, 546 patients underwent successful PDA occlusion at both institutions. Gianturco and Flipper coils were used in 120 (22%) and 119 (22%) patients respectively. A total of 152 (28%) patients received ADO and 155 (28%) patients received NOC. Immediate R.S. were noted in 226 (41.4%) patients in the entire study group with the NOC group having the highest percentage of R.S. (80/155, 51.6%, P = 0.004). Of the 484 patients with follow‐up echocardiograms at 6 months, 35 (7.2%) patients had persistent R.S. The NOC (3/143, 2.1%) and ADO (5/150, 3.3%) groups had the least R.S. at six months follow‐up. Conclusion : Per our definition of success, the Nit‐Occlud coils and the Amplatzer duct‐occluder devices had significantly higher success rate for PDA occlusion versus the coils. © 2010 Wiley‐Liss, Inc.  相似文献   

11.
目的 采用 Amplatzer封堵器和 Porstm ann海绵塞子封堵器方法 ,经皮穿刺动脉、静脉 ,治疗动脉导管未闭(PDA) ,并对其疗效 ,安全性进行评价。方法  2 0例患者 ,其中男 5例 ,女 15例 ,年龄 10~ 32岁。15例行 Porstm ann法 ,5例做 Am platzer法 ,均经临床症状、体检、EKG(心电图 )、X线胸片及超声心动图检查证实为 PDA。结果  2 0例患者手术都成功。术后即刻心前区连续性杂音消失。造影示 19例完全堵闭 ,仅 1例存在少量残余分流 ,术后发生溶血 ,经内科保守处理 96小时后超声心动图示分流消失。 2 0例病人随访 6~ 36个月未发现装置移位、再通或狭窄。结论  Amplatzer封堵器和 Porstmann封堵器经导管介入治疗 PDA是一种安全有效的治疗方法  相似文献   

12.
OBJECTIVES: The study aims to find safety of transcatheter closure of large patent ductus arteriosus (PDA) >or=4 mm in patients weighing or=4 mm in patients or=4 mm might be considered safe and effective in infants weighing 相似文献   

13.
In the present study, we report the initial clinical experience with the new angled Amplatzer duct occluder (ADO) for the percutaneous closure of patent ductus arteriosus (PDA). Percutaneous closure of PDA using standard ADO in infants and in patients with small PDA ampulla is difficult, or even impossible, due to protrusion of the aortic disk into the descending thoracic aorta. The aortic disk of an angled ADO is angled at 32 degrees to the body of the device and concave toward the aorta to prevent protrusion of the disk into the aorta. Percutaneous closure of PDA was attempted in nine patients with a median age of 5.2 years (range, 0.5-12.7) and median weight of 20 kg (range, 4.9-55). Selection of the occluder and the implantation technique were similar to the standard ADO. The minimal PDA diameter ranged from 2.1 to 3.7 mm (median, 2.5 mm). Occluders were successfully implanted in all patients. Immediate complete PDA closure was achieved in all patients. There were no complications. The new angled ADO is a safe and effective device for PDA closure, particularly suitable for infants and patients with small PDA ampulla. Further studies and long-term follow-up are necessary to confirm our initial experience.  相似文献   

14.
Objectives: To describe the technique and results of transcatheter closure of ventricular septal defects (VSDs) by a modified retrograde transarterial approach using the new Amplatzer Duct Occluder II (ADO II). Background: Transcatheter device closure of ventricular septal defects (VSDs) by antegrade method is well established, but a challenging procedure. We describe a retrograde technique that obviates the need for arteriovenous looping. Material and Methods: This is a prospective study from a single center. Between April 2009 and February 2010 13 children were identified for closure of various types of perimembranous and muscular VSDs using the ADO II device. All had met the criteria for surgical closure. Following left ventricular angiogram two were excluded as technically nonfeasible. The median age was 48 months (range 15–78). The median weight was 14 kg (range 7.5–20). The device was successfully deployed in the 11 selected children by the method described. The follow‐up evaluation included chest roentgenogram, ECG, and echocardiogram on day 1, at 6 weeks, at 3, 6, and 12 months. Results: The immediate and follow up complete closure rates were 73 and 82%, respectively. The median fluoroscopic time was 14 min (range 8.2–45). There were no procedure related complications. All patients were doing well at median follow up of 10 months; none showing any conduction abnormality. Conclusion: Transcatheter retrograde device closure of selected cases of Ventricular Septal Defects using the Amplatzer Duct Occluder II is simple and appears safe in the short term and can be completed within a short fluoroscopic time.© 2010 Wiley‐Liss, Inc.  相似文献   

15.
Objectives: The study aims to find safety of transcatheter closure of large patent ductus arteriosus (PDA) ≥4 mm in patients weighing ≤6 kg.
Background: Large PDA ≥4 mm in patients ≤6 kg challenge the interventionist due to need for large delivery sheath, kink of delivery sheath, and encroachment of aorta or pulmonary artery (PA) by the device. Many institutions refer them for surgery.
Methods: Preterm neonates and ducts with coarctation were excluded. All other patients were taken for catheter closure. Ducts with roomy ampulla were closed with multiple coils aided by bioptome, and others with Amplatzer duct occluders.
Results: Twenty-eight patients aged 2–18 months (median 5.5 months) and weighing 3.8–6 kg (median 4.7 kg) had large PDA (mean diameter 6.3 ± 2 mm) with hyperkinetic pulmonary hypertension. Four patients had bioptome-aided coil closure. Twenty-two other ducts were closed with devices. Two procedures failed due to sheath kink in one patient and device pulling through a duct in the other patient. Four infants needed blood transfusions. The mean procedural time was 42 ± 20 minutes. On a mean follow-up of 25.5 ± 14.8 months, there were no residual flows and no gradients across aorta or pulmonary artery.
Conclusions: Transcatheter closure of large ducts ≥4 mm might be considered safe and effective in infants weighing ≤6 kg also. Decision on coils versus devices depends on ductal morphology. On midterm follow-up with somatic growth, there was no occurrence of aortic or PA gradients.  相似文献   

16.
ObjectiveRetrospective analysis of feasibility, safety and advantages of device closure of patent ductus arteriosus (PDA) using only venous access.BackgroundArterial access for transcatheter device closure of PDA has been a standard practice, but has inherent complications, especially in infants.MethodRecords of patients who underwent PDA device closure from 2004 to 2012 were reviewed. Echocardiography was used for patient selection and for assessment of procedural outcome.Result151 out of 179 patients underwent PDA device closure with venous access alone, weighing 2.2–58 kg with half <10 kg and follow up of 6 months–8 years. Fluoroscopic time ranged from 2.2 to 16 min. Immediate closure was achieved in 146 patients. Two patients had new-onset left pulmonary artery turbulence and one had residual flow.ConclusionPDA device closure without arterial access can be accomplished safely and effectively in vast majority of patients including infants.  相似文献   

17.
Objectives : To describe a new percutaneous PDA device. Background : The ADO II was developed by AGA Medical for closure of small‐moderate sized PDAs via a small delivery catheter from an antegrade or retrograde catheter approach. The objective of this study was to evaluate the technical feasibility, safety, and efficacy of the ADO II in a canine PDA model. Methods : The ADO‐II consists of multi‐layer nitinol wire braid with symmetric retention disks and an articulating connecting center waist, without sewn‐in polyester, that can be delivered though a 4‐5F catheter. A PDA was surgically created in nine dogs. Transcatheter occlusion of the PDA was performed using the ADO II. Angiographic and hemodynamic data were obtained at 7, 30, 60, and 90 days post‐procedure. The devices were then harvested for pathology. Results : Devices were placed transarterially (n = 8) and transvenously (n = 1). All PDAs were occluded and there were no significant pressure gradients (P > 0.05) at the immediate and 90 post‐implant evaluations. Pathology found endothelial coverage on all aortic and pulmonary disks, except at the tip of the microscrew. There were no procedural complications. One canine was euthanized 4 hr after device implant because of a clinical deterioration. The staff veterinarian and pathologist concluded that the animal's illness was not device related. Conclusions : The Amplatzer ADO II devices can be safely deployed in animal models of PDAs, with complete resolution of the PDA shunt. The lower profile and symmetry of the ADO II allows for venous or arterial approach and smaller delivery catheter size. The ADO‐II is expected to be a preferred alternative for closure of small‐moderate PDAs. © 2009 Wiley‐Liss, Inc.  相似文献   

18.
Objectives: This study assessed the feasibility and efficacy of implanting a new miniaturized nitinol device to occlude the patent ductus arteriosus (PDA) in a newborn porcine model. Background: Transcatheter device closure is the standard of care for PDA in older children and adults. Currently available technology is not designed for the newborn infant. Methods: The Amplatzer Duct Occluder II 0.5 is a new transcatheter Nitinol device without fabric designed to close the PDA with small aortic and pulmonary artery structures. The device was implanted in 8 infant pigs (average weight 2,400 g) after balloon dilation of PDA (average diameter 2.7 mm, average length 5.8 mm) with immediate, ~ 7, ~ 30, and ~ 90 day follow‐up by echocardiography, angiography, and final pathological examination. Half were implanted arterial, and half venous. Results: The device was successfully implanted in all animals. There was complete occlusion of the PDA in all cases without obstruction of the pulmonary arteries or aorta. There was complete late endothelialization without thrombus. The only complication was transection of a femoral artery accessed by cutdown. Conclusions: The success of this animal study confirms safety and feasibility of the Amplatzer Duct Occluder II 0.5 (now known as the ADO II AS) for use when the aorta and pulmonary arteries are small. Consideration can be given to transcatheter closure of the PDA in preterm and other small infants with this device. © 2011 Wiley Periodicals, Inc.  相似文献   

19.
Percutaneous patent ductus arteriosus (PDA) closure is a safe and feasible treatment, and it is recommended over surgical approach in the majority of cases. Amplatzer duct occluder (ADO—AGA Medical Corporation, Golden Valley, MN) is the preferred device for transcatheter treatment of PDA. Recently, the ADO II (AGA Medical Corporation, Golden Valley, MN), allowing PDA closure through a small delivery catheter from an antegrade or retrograde approach, received the European Community mark approval. Here, we report, for the first time, successful PDA closure in a 66‐year‐old female with the ADO II device, using a transradial approach. © 2010 Wiley‐Liss, Inc.  相似文献   

20.
特殊形态动脉导管未闭的介入治疗   总被引:2,自引:0,他引:2  
目的探讨特殊形态动脉导管未闭(PDA)的介入治疗方法,评价其临床应用价值。方法7例应用标准型Amplatzer导管封堵器难以完成介入治疗的PDA患者,根据造影显示PDA形态及临床特点,相应选用成角型Amplatzer导管封堵器以及偏心型导管封堵器进行介入治疗,术后以心脏超声随诊评价疗效。结果7例患者皆成功完成介入治疗,无严重并发症发生;其中2例应用成角型Amplatzer导管封堵器,5例应用偏心型导管封堵器;2例经二次手术完成,余患者一次治疗完成。7例患者中,封堵术后即刻造影显示有2例封堵完全,术后24h心脏超声检查示6例封堵完全,术后3个月复查皆封堵完全。结论需要设计和生产不同形态和大小的封堵装置,以扩大PDA介入治疗的适应证。  相似文献   