共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
3.
4.
5.
6.
Arthrodesis of the distal interphalangeal joint of the hand is a reliable procedure for creating a painless stable joint. Numerous techniques are described within the literature for varying indications. We undertook a systematic review of all studies published within the English literature to provide a comparison of the different techniques. The published studies were predominantly of Level IV evidence. The most commonly employed techniques were Kirschner wire, headless compression screw and cerclage wires. There was no difference in infection rates. Headless compression screws appear to have increased union rates but are associated with complications not seen with other well-established and cheaper techniques. The screw diameter is often similar to or larger than the joint itself, which can result in penetration. Furthermore, they limit the available angle for achieving fusion. Other than in terms of union, there is insufficient evidence to show the headless compression screw is superior to other techniques. 相似文献
7.
8.
9.
10.
11.
Arthrodesis of the distal interphalangeal (DIP) joint is a reliable means of achieving pain relief in a symptomatic DIP joint
afflicted by a variety of degenerative, inflammatory, or posttraumatic conditions. Successful arthrodesis is more reproducible
when rigid compression of the joint is achieved. The emergence of an increasing number of commercially available headless
or variable pitch compression screws reflects the growing trend among hand surgeons to utilize rigid stabilization of the
DIP joint so that motion at more proximal levels can be initiated immediately without affecting arthrodesis rates. Successful
closed percutaneous DIP arthrodesis can be achieved in a patient with hypertrophic osteoarthropathy, passively correctable
deformity, and patients at increased risk for perioperative soft tissue complications associated with open arthrodesis. We
present a novel percutaneous DIP fusion technique utilizing a cannulated headless compression screw in a select group of patients.
The sagittal plane diameters of the distal and middle phalanges are templated. Cannulated headless compression screws, 2.4
and 3.0 mm, with short or long terminal threads at the leading end of the screw are selected based upon patient-specific anatomic
considerations. Pain-free status and radiographic fusion were achieved in both patients (gout arthropathy, n = 1; posttraumatic arthritis, n = 1) at an average of 6 weeks postoperatively. Our current indications, along with pearls and pitfalls with this technique,
are reviewed. In select patients, this percutaneous DIP joint arthrodesis is advantageous in comparison with open fusion techniques. 相似文献
12.
13.
14.
William J. Warrender David E. Ruchelsman Michael G. Livesey Chaitanya S. Mudgal Michael Rivlin 《Hand (New York, N.Y.)》2020,15(6):798
Background: There has been a recent increase in the use of headless compression screws for fixation of metacarpal neck and shaft fractures as they offer several advantages, and minimal complications have been reported. This study aimed to evaluate the clinical complications and their solutions following retrograde intramedullary headless compression screw fixation of metacarpal fractures. We describe complications and the approach to their management. Methods: We performed a multicenter case series through retrospective review of all patients treated with intramedullary headless screw fixation of metacarpal fractures by 3 fellowship-trained hand surgeons. Patient demographics, implant used, type of complication, pre- and postoperative radiographs, operative reports, and sequelae were reviewed for each case. We defined complications as infection, loss of fixation, hardware failure, malrotation, nonunion, malunion, metal allergy, and any repeat surgical intervention. Results: Four complications (2.5%) were identified through the review of 160 total metacarpal fractures. One complication was a nickel allergy, one was a broken screw after repeat trauma, and 2 patients had bent intramedullary screws. Screw removal in 3 patients was simple and without complications or persistent limitations. One bent screw with a refracture was left in place. No serious complications were seen. Conclusion: Intramedullary screw fixation of metacarpal fractures is safe with a low incidence of complications (2.5%) that can be safely and effectively managed. 相似文献
15.
16.
17.
18.
19.