首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
2.
The appropriate communication and management of incidental findings on emergency department (ED) radiology studies is an important component of patient safety. Guidelines have been issued by the ACR and other medical associations that best define incidental findings across various modalities and imaging studies. However, there are few examples of health care facilities designing ways to manage incidental findings. Our institution aimed to improve communication and follow-up of incidental radiology findings in ED patients through the collaborative development and implementation of system-level process changes including a standardized loop-closure method. We assembled a multidisciplinary team to address the nature of these incidental findings and designed new workflows and operational pathways for both radiology and ED staff to properly communicate incidental findings. Our results are based on all incidental findings received and acknowledged between November 1, 2016, and May 30, 2017. The total number of incidental findings discovered was 1,409. Our systematic compliance fluctuated between 45% and 95% initially after implementation. However, after overcoming various challenges through optimization, our system reached a compliance rate of 93% to 95%. Through the implementation of our new, standardized communication system, a high degree of compliance with loop closure for ED incidental radiology findings was achieved at our institution.  相似文献   

3.
PurposeThe aim of this study was to scale structured report templates categorizing actionable renal findings across health systems and create a centralized registry of patient and report data.MethodsIn January 2017, three academic radiology departments agreed to prospectively include identical structured templates categorizing the malignant likelihood of renal findings in ≥90% of all adult ultrasound, MRI, and CT reports, a new approach for two sites. Between November 20, 2017, and September 30, 2019, deidentified HL7 report data were transmitted to a centralized ACR registry. An automated algorithm extracted categories. Radiologists were requested to addend reports with missing or incomplete templates after the first month. Separately, each site submitted patient sociodemographic and clinical data 12 months before and at least 3 months after enrollment.ResultsA total of 164,982 eligible radiology reports were transmitted to the registry; 4,159 (2.5%) were excluded because of missing categories or radiologist names. The final cohort included 160,823 examinations on 102,619 unique patients. Mean template use before and after addendum requests was 99.3% and 99.9% at SITE1, 86.5% and 94.6% at SITE2, and 91.4% and 96.0% at SITE3. Matching patient sociodemographic and clinical data were obtained on 96.9% of reports from SITE1, 94.2% from SITE2, and 96.0% from SITE3. Regulatory, cultural, and technology barriers to the creation of a multisite registry were identified.ConclusionsBarriers to the adoption of unified structured report templates for actionable kidney findings can be addressed. Deidentified report and patient data can be securely transmitted to an external registry. These data can facilitate the collection of diverse evidence-based population imaging outcomes.  相似文献   

4.
5.

Purpose

Our aims were to analyze the change in interventional radiology physician major adverse event (AE) reporting after initiation of a monthly morbidity and mortality (M&M) conference compliance review and to describe the association of procedure class and potentially preventable errors with major AE occurrence.

Methods

In late 2010, to motivate timely reporting, we instituted a structured monthly M&M conference review confirming whether each complication warranted institutional AE reporting and whether timely reporting had occurred. In this study, we retrospectively analyzed the M&M conference minutes over the subsequent 5 years. Logistic regression was used to model the change of AE reporting over time as well as the association of procedure class with the risk of an AE. Each AE was classified as to whether it seemed potentially preventable.

Results

There were 46,660 patient encounters, 1,160 (2.5%) major and minor complications, and 462 (1.0%) reportable AEs. From 2011 to 2015, the percentage of reportable AEs reported increased from 67% to 98%. The number of months from initiation of the M&M conference review was a significant predictor of the likelihood of AE reporting (odds ratio 1.06, 95% confidence interval 1.04, 1.08, P < .0001). Procedure class was strongly associated with the risk of a reportable AE (P < .0001). At least 111 (24%) reportable AEs were potentially preventable.

Conclusions

Increasing AE reporting occurred after initiation of a monthly M&M conference compliance review. The incidence of reportable AEs was strongly associated with procedure class, and a significant percentage of these events were potentially preventable.  相似文献   

6.
RATIONALE AND OBJECTIVES: The authors performed this study to investigate the impact of changing from a film-based image interpretation system to one using digital image workstations on the training of radiology residents in the interpretation of radiographs. MATERIALS AND METHODS: Data were collected during a period when a conventional system of image interpretation with hard-copy images and multiviewers was used and during a period when digital image workstations were used. During each period, it was noted whether the first interpretation of the radiographs was performed by a radiology resident, by an attending radiologist, or as a group effort including both an attending radiologist and a radiology resident(s). In addition, it was noted whether a radiology resident or an attending radiologist dictated the report. RESULTS: The proportion of images first interpreted by the radiology resident alone decreased from 38% (53 of 139) when using the conventional system to 17% (34 of 199) after the switch to interpreting images on the workstations (P = .001). During the film-based period, radiology residents dictated 45% of reports (141 of 312), but during the workstation period, radiology residents dictated only 4% of reports (24 of 667; P = .001). CONCLUSION: The authors observed a decrease in autonomous participation by radiology residents in image interpretation and dictation of reports and an increase in "group reading" after the switch from a film-based system to a workstation system.  相似文献   

7.
8.
9.
10.
ObjectiveSince its introduction in 2011, the CT/MRI diagnostic Liver Imaging Reporting and Data System (LI-RADS) has been updated in 2014, 2017, and 2018. We evaluated the impact of CT/MRI diagnostic LI-RADS on liver MRI research methodology for the diagnosis of hepatocellular carcinoma (HCC).Materials and MethodsThe MEDLINE, EMBASE, and Cochrane databases were searched for original articles reporting the diagnostic performance of liver MRI for HCC between 2011 and 2019. The MRI techniques, image analysis methods, and diagnostic criteria for HCC used in each study were investigated. The studies were classified into three groups according to the year of publication (2011–2013, 2014–2016, and 2017–2019). We compared the percentage of studies adopting MRI techniques recommended by LI-RADS, image analysis methods in accordance with the lexicon defined in LI-RADS, and diagnostic criteria endorsed by LI-RADS. We compared the pooled sensitivity and specificity between studies that used the LI-RADS and those that did not.ResultsThis systematic review included 179 studies. The percentages of studies using imaging techniques recommended by LI-RADS were 77.8% for 2011–2013, 85.7% for 2014–2016, and 84.2% for 2017–2019, with no significant difference (p = 0.951). After the introduction of LI-RADS, the percentages of studies following the LI-RADS lexicon were 0.0%, 18.4%, and 56.6% in the respective periods (p < 0.001), while the percentages of studies using the LI-RADS diagnostic imaging criteria were 0.0%, 22.9%, and 60.7%, respectively (p < 0.001). Studies that did not use the LI-RADS and those that used the LI-RADS version 2018 showed no significant difference in sensitivity and specificity (86.3% vs. 77.7%, p = 0.102 and 91.4% vs. 89.9%, p = 0.770, respectively), with some difference in heterogeneity (I2 = 94.3% vs. 86.7% in sensitivity and I2 = 86.6% vs. 53.2% in specificity).ConclusionLI-RADS imparted significant changes in the image analysis methods and diagnostic criteria used in liver MRI research for the diagnosis of HCC.  相似文献   

11.
12.
13.
PurposeThe aim of this study was to assess the impact of a structured reporting template on adherence to the Prostate Imaging Reporting and Data System (PI-RADS) version 2 lexicon and on the diagnostic performance of prostate MRI to detect clinically significant prostate cancer (CS-PCa).MethodsAn imaging database was searched for consecutive patients who underwent prostate MRI followed by MRI-ultrasound fusion biopsy from October 2015 through October 2017. The initial MRI reporting template used included only subheadings. In July 2016, the template was changed to a standardized PI-RADS-compliant structured template incorporating dropdown menus. Lesion, patient characteristics, pathology, and adherence to the PI-RADS lexicon were extracted from MRI reports and patient charts. Diagnostic performance of prostate MRI to detect CS-PCa using combined ultrasound-MRI fusion and systematic biopsy as a reference standard was assessed.ResultsThree hundred twenty-four lesions in 202 patients (average age, 67 years; average prostate-specific antigen level, 5.9 ng/mL) were analyzed, including 217 MRI peripheral zone (PZ) lesions, 84 MRI non-PZ lesions, and 23 additional PZ lesions found on systematic biopsy but missed on MRI. Thirty-three percent (106 of 324) were CS-PCa. Adherence to the PI-RADS lexicon improved from 32.9% (50 of 152) to 88.4% (152 of 172) (P < .0001) after introduction of the structured template. The sensitivity of prostate MRI for CS-PCa in the PZ increased from 53% to 70% (P = .011). There was no significant change in specificity (60% versus 55%, P = .458).ConclusionsA structured template with dropdown menus incorporating the PI-RADS lexicon and classification rules improves adherence to PI-RADS and may increase the diagnostic performance of prostate MRI for CS-PCa.  相似文献   

14.
使用美国制造的标准化SPECT体模,对SPECT设备进行了包括断层均匀性、空间分辨力、空间线性和影像对比度等多项参数在内的成像性能检测。本文简介了检测方法、测量结果及评价标准,着重讨论断层影像相对于平面影像均匀性与线性大幅度下降的原因,最后就SPECT设备QA(QC)检测计划的建立与实施提出了建议。  相似文献   

15.
ObjectiveAssess impact of a multifaceted pay-for-performance (PFP) initiative on radiologists’ behavior regarding key quality and safety measures.MethodsThis institutional review board–approved prospective study was performed at a large, 12-division urban academic radiology department. Radiology patient outcome measures were implemented October 1, 2017, measuring report signature timeliness, critical results communication, and generation of peer-learning communications between radiologists. Subspecialty division-wide and individual radiologist targets were specified, performance was transparently communicated on an intranet dashboard updated daily, and performance was financially incentivized (5% of salary) quarterly. We compared outcomes 12 months pre- versus 12 months post-PFP implementation. Primary outcome was monthly 90th percentile time from scan completion to final report signature (CtoF). Secondary outcomes were percentage timely closed-loop communication of critical results and number of division-wide peer-learning communications. Statistical process control analysis and parallel coordinates charts were used to assess for temporal trends.ResultsIn all, 144 radiologists generated 1,255,771 reports (613,273 pre-PFP) during the study period. Monthly 90th percentile CtoF exhibited an absolute decrease of 4.4 hours (from 21.1 to 16.7 hours) and a 20.9% relative decrease post-PFP. Statistical process control analysis demonstrated significant decreases in 90th percentile CtoF post-PFP, sustained throughout the study period (P < .003). Between 95% (119 of 125, July 1, 2018, to September 30, 2018) and 98.4% (126 of 128, October 1, 2017, to December 31, 2017) of radiologists achieved >90% timely closure of critical alerts; all divisions exceeded the target of 90 peer-learning communications each quarter (range: 97-472) after January 1, 2018.DiscussionImplementation of a multifaceted PFP initiative using well-defined radiology patient outcome measures correlated with measurable improvements in radiologist behavior regarding key quality and safety parameters.  相似文献   

16.
The ACR Council passed Resolution 47 at its 2020 annual meeting establishing a representative task force (TF) to explore the concept of the “multispecialty radiologist,” previously proposed in 2012. The TF held eight virtual meetings over 8 months, considered data from a 2020 ACR Membership Tracking Survey, conducted a review of current literature, and collected anecdotal experience from TF members and ACR leadership. ACR legal counsel and a cross-section of ACR Commissions and Committees also provided input. The TF concluded that there is scant interest from the radiology community in the multispecialty radiologist title and no agreed-upon definition for the term. Radiologists may identify as diagnostic or subspecialty radiologists; however, the roles they fill in clinical practice include general, multispecialty, and subspecialized radiology. The TF proposes definitions for each of these terms to support radiologist recruitment aligned with optimal patient care in the practice community and to improve the quality of data collection about the field. To reduce ambiguity, the TF proposes adoption of the defined terms by the radiology community, including radiologist recruiters and employers, and suggests ways in which resident training and the ABR board examination can be adapted to support this new structure. Additionally, as part of an exploration of hyperspecialization and trainee preparedness for clinical practice, the TF discussed the challenges faced by community-based practices seeking to provide a full range of high-quality, radiologist-delivered diagnostic and interventional services to their patient populations.  相似文献   

17.
目的 引入CAN现场总线和嵌入式技术改进航天飞行训练模拟器接口系统.方法 提出了基于CAN总线,ITM (interface transform module)+ CPM (center process module)的设计思路和技术途径.ITM具备某种接口功能,并转换成CAN数据,ITM之间彼此独立,地位平等,作为一...  相似文献   

18.
目的 为载人离心机研制能模拟不同形状过载曲线的测控系统。方法 采用测控计算机和实时控制器的上下位机控制方案。结果 系统性能满足载人离心机试验要求。结论 测控系统功能完善,安全可靠,操作简单,控制精度高。  相似文献   

19.
Scientific reporting and communication is a challenging topic for which traditional study programs do not offer structured learning activities on a regular basis. This paper reports on the development and implementation of a web application and associated learning activities that intend to raise the awareness of reporting and communication issues among students in forensic science and law. The project covers interdisciplinary case studies based on a library of written reports about forensic examinations. Special features of the web framework, in particular a report annotation tool, support the design of various individual and group learning activities that focus on the development of knowledge and competence in dealing with reporting and communication challenges in the students’ future areas of professional activity.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号