首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Forty-five cemented total hip replacements in thirty-eight patients who were less than fifty years old were followed with physical examinations and radiographs for five to eleven years (average, 7.3 years) after surgery. The average age of the patients at the time of surgery was 40.7 years. The average Iowa hip rating at follow-up was 91.9 points (range, 58 to 100 points). No surgical deaths, infections, or dislocations were encountered. All of the patients had been repeatedly advised to avoid running, jumping, heavy labor, and lifting more than forty pounds (eighteen kilograms). Revision of a prosthetic component was necessary in four hips (8.9 per cent); all of the revisions were successful. Radiolucent lines were seen about the acetabular components of thirty-one hips but in only three (6.6 per cent) were these judged to be progressive bone-cement demarcation lines. Only one of those three hips was symptomatic. Three hips (6.6 per cent) also had subsidence of the femoral component into the femoral canal, but only one hip was symptomatic. Resorption of the medial aspect of the proximal end of the femur was seen in five hips, the maximum resorption being three to five millimeters. I have concluded that cemented total hip arthroplasty can give acceptable results in patients who are thirty to fifty years old, and that the result can be reasonably long-lasting if the patients are willing to avoid strenuous activity.  相似文献   

2.
Forty primary uncemented total hip arthroplasties (THAs) were performed in 34 patients with an average age of 41.2 years (range, 21-78 years). Four hips had one component placed with cement: three femoral, one acetabular. Diagnoses included rheumatoid arthritis (30 hips), juvenile rheumatoid arthritis (seven hips), and systemic lupus erythematosus (three hips). The follow-up period averaged 3.7 years (range, two to six years). Thirty-five percent of the patients were using corticosteroids before hip replacement and throughout the follow-up period, whereas 44% of the patients had been using steroids in the past. Additionally, 79% of the patients were taking some form of antiinflammatory medications at follow-up examination. Clinical evaluation based on a ten-point rating scale indicated significant improvements from preoperative to the most recent follow-up examination for pain (from 3.1 to 9.0), walking (4.0-7.3), function (3.5-6.0), and activity (3.0-4.9). None of the hips required revision surgery, and none are pending. There was no evidence of roentgenographic failure; however, 43% of femoral and 12.8% of acetabular components showed some minor radiolucencies with sclerotic lines. None of these involved 100% of the bone-prosthesis interface. Femoral component subsidence occurred in two hips, and acetabular component migration occurred in one hip. Complications included three (8.1%) intraoperative femoral fractures, of which two required internal fixation. One patient had postoperative, culture negative, wound drainage. No deep sepsis occurred. These findings suggest that uncemented THA may be successful in the rheumatoid patient. Pain relief, walking, function, and activity levels are similar to those seen in cemented replacements with this length of follow-up period.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
From January 1979 to February 1982, 143 patients (seventy-nine women and sixty-four men) with 146 uninfected cemented total hip arthroplasties had revision cemented hip arthroplasty at The Hospital for Special Surgery for what was considered to be mechanical failure. The average age of the patients at primary arthroplasty was 56.1 years and at revision, 62.1 years. Loosening of the femoral component before revision correlated with varus positioning in 50 per cent of the hips, inadequate cement in 34 per cent, and a relatively young age in 16 per cent. The average age of the patients (fifteen hips) with a loose femoral component that had been placed in a neutral or valgus position with good cementing technique was 48.2 years at the time of primary arthroplasty. Loosening of the acetabular component was attributed to high placement of the cup in 41 per cent, inadequate bone in 18 per cent, a vertical orientation of the opening of the cup in 7 per cent, and poor cementing technique in 3 per cent. Complications associated with revision included perforation of the femoral cortex in 13 per cent, postoperative deep infection in 3.4 per cent, postoperative dislocation in 8.2 per cent, trochanteric complications in 6.2 per cent, and sciatic palsy in 0.7 per cent. Of the 139 hips that were followed for an average of 3.6 years (range, two to five years) after revision, the results were excellent in 59 per cent, good in 7 per cent, fair in 16 per cent, and poor in 18 per cent. After revision of the 139 hips, 29 per cent showed progressive radiolucencies; 18 per cent, femoral subsidence; and 9 per cent, acetabular migration. Definite mechanical failure after revision was identified in 15.8 per cent of the hips. These failures were due to loosening in 12.2 per cent of the hips, femoral fracture in 2.2 per cent, and disabling dislocation in 1.4 per cent. At the time of follow-up, twelve hips (8.6 per cent) had been revised a second time: six (4.3 per cent) for loosening of one or both components, three (2.2 per cent) for femoral fracture, and three (2.2 per cent) for infection. Mechanical failure and progressive radiolucencies were associated with poor quality of bone (p less than 0.001) and inadequate anatomical reconstruction (p less than 0.03).  相似文献   

4.
Seventy-five primary cemented total hip arthroplasties (THAs) were performed in 53 patients with rheumatoid arthritis and juvenile rheumatoid arthritis. All patients were followed for an average of 7.4 years, unless their prosthetic hips failed before that time. Clinical evaluation was based on a 10-point maximum rating scale, and ratings for pain, walking, function, and activity improved from preoperative values to the most recent follow-up examination. Revision THA was performed for aseptic acetabular loosening in four hips, and femoral loosening in one hip. Sepsis occurred in another four hips. Complications of wound healing occurred in 14 hips. Roentgenographic evidence of loosening was seen in six acetabular components, in three femoral components, and in the femoral and acetabular component of one hip; none of these hips have as yet required revision THA. The Kaplan-Meier survivorship analysis revealed a 93% survival probability at seven years, which fell to 77% at 12 years in these patients. A trend was that younger, larger patients had increased failure and component loosening rates. Cemented primary THA has been a satisfactory operation in the rheumatoid patient. The relatively high rate of wound healing problems and sepsis may be due to the systemic immune nature of rheumatoid arthritis; however, 25% of these prosthetic hips either failed or are at risk for future failure. Thus, improved techniques are still necessary to increase the long-term success of THA in the rheumatoid patient.  相似文献   

5.
We reviewed the cases of thirty-six patients who had forty cemented total hip replacements with the Harris metal-backed acetabular component. The operations were done between 1972 and 1977, and the duration of follow-up averaged 7.6 years (range, five to 10.8 years). The average age of the patients was forty-four years (range, sixteen to sixty-two years). Aseptic loosening of the acetabular component occurred in three hips (7.5 per cent), and three more sockets were revised for other reasons. Two of the three sockets with aseptic loosening were in the fifteen patients (seventeen hips) who were forty-five years old or younger. The remaining loose cup was in one of the twenty-one patients (twenty-three hips) who were forty-six years old or older. The reduction in the rate of aseptic loosening of the socket in our series, compared with the higher rates reported in similar long-term studies in which other acetabular components were used, supports the conclusion that there is enhanced longevity of acetabular fixation when a metal-backed acetabular component is used in cemented total hip arthroplasty.  相似文献   

6.
A retrospective review was undertaken of thirty-seven hips (thirty-four patients) that had had a complex cemented total hip arthroplasty. In these hips, circumstances had necessitated that the center of the hip be placed farther proximally, as measured from the interteardrop line, than the anatomical position that is normally used. The mean duration of clinical and roentgenographic follow-up was eleven years (range, seven to seventeen years), and the mean age of the patients was fifty-one years (range, sixteen to seventy-three years). Most of these hips had a major deficiency or defect of the acetabular bone stock, or both. Of the six acetabular components (16 per cent) that became loose and were followed for ten years, only one needed revision. Because this study was aimed specifically at assessment of the acetabular component, if the femoral component alone needed revision, the final clinical rating that was used was the one obtained after the femoral revision. Thirty-one hips (84 per cent) were rated as having a good or excellent result; they had an average Harris hip-rating score of 43 points preoperatively and 93 points postoperatively. Thirty-three of the thirty-seven acetabular components were not substantially displaced laterally as compared with the anatomical location that is normally used. Our findings suggest that, when circumstances dictate, proximal positioning of the acetabular component without lateral displacement can give an acceptable result in cemented total hip-replacement procedures.  相似文献   

7.
Fifty patients requiring bilateral total hip arthroplasty underwent a concomitant conventional hip arthroplasty on one side and an articular resurfacing procedure on the other, done by the senior one of us (M. A. R.). The average age of the patients was sixty-two years (range, twenty-one to eighty-seven years), and forty-seven of them were followed with serial radiographs and clinical evaluation for one year or more. The length of follow-up was five years for thirty-four patients with both prostheses intact. The average pain score for all hips at three years postoperatively was 5.5 points. Although the majority of patients at each follow-up interval did not prefer one procedure to the other, the conventional arthroplasty was significantly superior for those who had a preference, and radiographic evaluation revealed a statistically significant increased incidence of acetabular lucency at the bone-cement interface of the resurfacing arthroplasty at one, two, three, five, and seven years postoperatively (p less than 0.002). Two of the conventional prostheses were revised during this time-period (one because of infection and one, a broken stem) whereas thirteen (26 per cent) of the resurfacing prostheses were revised (eight hips had femoral loosening, five with concomitant acetabular loosening; three had acetabular loosening; and one had a femoral neck fracture) at an average of fifty-two months postoperatively (p less than 0.001).  相似文献   

8.
A clinical and roentgenographic study was done on 52 primary total hip arthroplasties (THAs) in which all patients were treated with hip reconstruction with a combination of a cementless, porous-coated acetabular component and a cemented femoral component. The operations were performed between November 1982 and May 1984, and the patients were followed for an average of 31 months (range, 24-40 months). The average age of the patients (55 years) was younger than in many THA series. At the last follow-up assessment, 50 hips were classified as good or excellent, one as fair, and one as a poor result. No total hip component required revision. No acetabular components had migrated as judged by conventional roentgenographic examination, and only one hip had progressive radiolucencies around the acetabular component. No femoral component was rated definitely loose or probably loose, and only one was rated possibly loose. If long-term follow-up study confirms these preliminary results, the combination of a cemented femoral component with a cementless socket may prove to be of value for selected patients requiring THA.  相似文献   

9.
BACKGROUND: This report presents the results of the senior author's initial twenty-five-year experience with the use of Charnley total hip arthroplasty with cement. The purpose of this paper was to evaluate the long-term results of total hip arthroplasty. METHODS: Between July 1970 and April 1972, the senior author (R. C. J.) performed 330 Charnley total hip replacements with cement using a hand-packing cement technique in 262 patients. Fifty-one patients (sixty-two hips) who were alive at least twenty-five years post-operatively were evaluated from a clinical standpoint with use of a standard-terminology questionnaire. The average age of this group at the time of surgery was fifty-six years (range, thirty-five to seventy-one years) compared with sixty-five years (range, twenty-one to eighty-nine years) for the entire group. All patients were evaluated for radiographic changes at the time of their most recent follow-up. Of the fifty-one patients (sixty-two hips) who were alive at least twenty-five years postoperatively, thirty-one (thirty-six hips) had a follow-up radiograph made at a minimum of twenty-five years after the surgery. The average duration of radiographic follow-up for the fifty-one patients was 22.7 years (range, two to twenty-seven years). RESULTS: Of the sixty-two hips in the fifty-one patients who were alive at least twenty-five years postoperatively, fourteen (23 percent) had been revised. Three (5 percent) had the revision because of loosening with infection; eleven (18 percent), because of aseptic loosening; and none, because of dislocation. The prevalence of revision due to aseptic loosening of the acetabular component in all 316 hips (excluding those that were lost to follow-up or that were revised for infection or dislocation) was 6 percent (eighteen hips), whereas the prevalence in the fifty-nine hips (excluding the three revised for infection) in the patients who were alive at least twenty-five years after the arthroplasty was 15 percent (nine hips). The prevalence of revision because of aseptic loosening of the femoral component in all 316 hips was 3 percent (nine hips), and the prevalence in the fifty-nine hips in the living patients was 7 percent (four hips). In the group of living patients, osteolysis occurred in Gruen zone 1 or 7 in thirty-three hips and in Gruen zones 2 through 6 in two hips. Ballooning acetabular osteolysis occurred in five hips. Of the 327 hips for which the outcome was known after a minimum of twenty-five years, 295 (90 percent) had retained the original implants until the patient died or until the most recent follow-up examination. Of the sixty-two hips in patients who lived for at least twenty-five years after the surgery, forty-eight (77 percent) had retained the original prosthesis. CONCLUSIONS: Our follow-up study at twenty-five years following Charnley total hip arthroplasty with cement demonstrates the durability of the results of the procedure. These results should provide a means for comparison with the results of newer cementing techniques as well as those associated with newer cemented and cementless hip designs.  相似文献   

10.
BACKGROUND: This follow-up study updates the results in a consecutive series of nineteen cemented total hip replacements with a swan-neck femoral component in patients with congenital dislocation or severe hip dysplasia. The series was previously reported on in 1993. METHODS: The patients were petite, with an average height of 152 cm and an average weight of 50 kg, and the femoral canals could not accommodate an off-the-shelf femoral component. Sixteen of the nineteen hips were available for follow-up at an average of 13.3 years (range, eleven to twenty years). Fourteen hips had up-to-date clinical and radiographic examinations. RESULTS: At the time of the latest follow-up, thirteen hips were rated as excellent; two, as good; and one, as a failure because of loosening of both components requiring revision eleven years after the index operation. Another hip required acetabular revision because of loosening fifteen years after the index operation. The rates of femoral and acetabular component revision were 6% and 12.5%, respectively. Radiographic analysis demonstrated that no femoral component was loose. One cup was definitely loose at 19.5 years, and three cups were possibly loose at an average of fourteen years. The radiographic rate of acetabular loosening was 33%. The total rate of cup failure (radiographic loosening and revision) was 43%. CONCLUSIONS: The excellent clinical and radiographic results associated with the swan-neck femoral component, and the 94% rate of survival, at an average of 13.3 years (range, eleven to twenty years) indicate that the biomechanical objectives of this custom-designed prosthesis for patients with congenital dislocation or severe hip dysplasia were met. On the basis of this favorable long-term experience, we still use this prosthesis when the anatomic abnormality cannot be adequately addressed by use of a commercially available prosthetic component.  相似文献   

11.
The influence of treatment with indomethacin in the first 6 postoperative weeks on the incidence of early loosening and radiolucencies following cemented total hip replacement were studied in 102 hips. Ninety-nine hips in 99 patients without postoperative antiinflammatory treatment served as control group. One year after surgery, two patients in the indomethacin group and five patients in the control group were suspected of having loosening of one or both prosthetic components. However, no patients had a revision. The lateral acetabular cement-bone interface most frequently showed a radiolucent line. Concerning the incidence of radiolucent lines in any acetabular or femoral cement-bone interface zone, no difference could be shown between the two groups. When evaluated 1 year after surgery, postoperative treatment with indomethacin does not increase the incidence of aseptic loosening or cement-bone interface radiolucencies in cemented total hip replacement.  相似文献   

12.
人工全髋关节置换术后翻修的假体选择   总被引:9,自引:5,他引:4  
目的探讨人工全髋关节置换术后翻修的假体选择. 方法 1995年1月~2002年6月进行全髋关节翻修术33例(33髋),其中男7髋,女26髋.翻修原因:无菌性松动22例,感染后松动8例(其中2例合并窦道形成);股骨头置换术后髋臼磨损3例,不伴有假体中心性脱位.对无菌性松动和股骨头磨损患者采用骨水泥固定型假体13例,生物固定型假体12例,股骨侧翻修假体均选择骨水泥固定型广泛涂层假体,8例感染患者均行一期骨水泥固定型全髋置换. 结果随访6个月~7年6个月,平均3年11个月.2例出现X线透亮带,但无临床不稳;4例遗留持续性疼痛,无假体脱位、断裂.本组Harris评分由术前的24~47分(平均38.6分),上升为术后的68~88分(平均82.4分),满意率87.9%. 结论无菌性松动是全髋关节置换术后翻修的主要原因.髋臼侧翻修假体可选择骨水泥型假体、也可选择生物型假体,股骨侧翻修假体均选择骨水泥固定型广泛涂层假体,感染后的翻修选择骨水泥假体较好.  相似文献   

13.
BACKGROUND: Acetabular revision in patients with rheumatoid arthritis is often difficult because of the poor quality and quantity of the acetabular bone stock. The purpose of this study was to evaluate the midterm clinical and radiographic outcomes of acetabular revision with use of an impaction bone-grafting technique and a cemented polyethylene cup. METHODS: Thirty-five consecutive acetabular revisions were performed with impaction bone-grafting and use of a cemented cup in twenty-eight patients with rheumatoid arthritis. The average age at the revision was fifty-seven years. The minimum duration of follow-up of all reconstructions that were still functioning or that were followed until the time of death was three years (mean, 7.5 years; range, three to fourteen years). No patient was lost to follow-up, but five patients (six hips) died before the time of the review. The acetabular bone defects were classified as cavitary in twelve hips and as combined segmental-cavitary in twenty-three. RESULTS: The five patients (six hips) who died had been doing well at the time of their latest follow-up. Of the remaining patients, six (six hips) had a repeat revision. The average Harris hip score of the living patients with a surviving implant at the time of follow-up was 82 points, and there was no or only mild pain in twenty-one of the twenty-three hips. Radiographic analysis of all twenty-nine hips that had not been revised showed loosening in one hip and a nonprogressive radiolucent line in one zone in two others. Kaplan-Meier analysis demonstrated a prosthetic survival rate, with aseptic loosening as the end point, of 90% at eight years. CONCLUSION: Acetabular revision with impaction bone-grafting and a cemented cup in patients with rheumatoid arthritis had acceptable results at an average of 7.5 years postoperatively.  相似文献   

14.
The purpose of the current study was to update the results of a prospective, single-surgeon series of primary Charnley total hip arthroplasties performed with cement. This investigation is one of the first studies in which hips treated with total hip arthroplasty with cement were followed for a minimum of thirty years. Twenty-seven patients (thirty-four [10.3%] of the hips in the initial study group) were alive at a minimum of thirty years postoperatively. These patients served as the focus of the present study. Revision because of aseptic loosening of the acetabular component was performed in 7.3% (twenty-three) of the hips from the original study group (excluding those revised because of infection or dislocation) and 26% (eight) of the hips in the living cohort. Revision because of aseptic loosening of the femoral component was performed in 3.2% (ten) of the hips from the original study group (excluding those revised because of infection or dislocation) and 10% (three) of the hips in the living patients. Since the twenty-five-year review, three hips were revised (one because of acetabular loosening, one because of femoral loosening, and one because of instability). This end-result study demonstrated the remarkable durability of cemented Charnley total hip replacements over a span of three decades, with 88% of the original prostheses intact at the time of the final follow-up or at the patient's death.  相似文献   

15.
The results of 123 total hip replacements with a noncemented Harris-Galante I acetabular component were reviewed (minimum 5-year clinical follow-up). The average clinical follow-up was 7 years (range, 5-10.8 years). No acetabular components were revised for loosening. One cup was revised for recurrent dislocation. In 3 cases, the acetabular liner was replaced at the time of femoral component revision (aseptic loosening), and in 1 case, a liner was revised because of recurrent dislocations. Of the hips, 92 had a complete set of radiographs for analysis. None of the acetabular components had migrated. Of the 92 acetabular components, 90 were considered radiographically stable (98%). Of these hips, 24 had linear radiolucencies of < or =2 mm in < or =2 of 4 zones and were considered stable. Two cups (2%) were considered possibly unstable. One of these had a linear radiolucent line in 3 zones, and the other had an osteolytic lesion measuring 6 x 11 mm in greatest dimensions. No acetabular components were definitely unstable. The average Harris Hip Score improved from 50 points (range, 17-89 points) preoperatively to 95 points (range, 74-99 points) at the latest follow-up examination. The average Hospital for Special Surgery hip score improved from 21 points (range, 10-31 points) preoperatively to 38 points (range, 27-40) at the last follow-up examination. Noncemented acetabular fixation with the Harris-Galante I component showed excellent clinical results at a minimum of 5 years' follow-up.  相似文献   

16.
This is a prospective, consecutive study of 98 total hip arthroplasties implanted by 1 surgeon in 66 patients with rheumatoid arthritis. The mean follow-up time was 7.4 years (range, 2-13 years). All 98 acetabular components were uncemented titanium fiber metal-coated components fixed with multiple screws. Sixty-five hips had bulk or cancellous allograft for protrusio acetabuli. Following a prospective protocol based on patient age, 51 hips had an uncemented femoral component, and 47 hips had a cemented femoral component. Using the Harris Hip Score, 30 hips were rated as excellent; 44, good; 15, fair; and 9, poor. There were no early deep infections. One hybrid hip was removed for late metastatic infection at 7 years. Radiographic evaluation of 98 acetabular components showed 1 case of septic loosening, 2 cases of aseptic loosening (1 patient asymptomatic), and 1 case with severe wear and ischial osteolysis. None of the 47 cemented femoral components subsided, and osteolysis was seen in only 3 femora (7%). Of the 51 uncemented femoral components, subsidence occurred in 7 hips (14%), and osteolysis occurred in 15 hips (30%). Uncemented acetabular components have a high rate of success in patients with rheumatoid arthritis who have a total hip arthroplasty. There is a high rate of subsidence and osteolysis, however, with first-generation cementless femoral components.  相似文献   

17.
Twenty-three of twenty-nine hips that were previously reported on were studied at an average of fourteen years (range, eight to 16.5 years) after total hip arthroplasty with cement. The original arthroplasties had been performed between November 1971 and January 1976. In all hips, there was dislocation or severe dysplasia. In six hips, superolateral bone grafts were used to increase acetabular coverage. At the latest follow-up examination, seven hips were rated excellent; nine, good; and one, fair. There were six failures (26 per cent) that were revised: four hips (17 per cent) had a fractured Trapezoidal-28 stem, one had loose femoral and acetabular components, and one had loosening of only the acetabular component. Radiographic analysis of the remaining hips revealed that one had progressive acetabular radiolucencies. This patient had an excellent clinical result. Two-thirds of the failures were due to a fractured stem.  相似文献   

18.
The outcome and complications of 37 primary total hip arthroplasties by one surgeon in 24 patients with Charnley Class C juvenile idiopathic arthritis with up to 19.6 years follow-up are reported. Twenty-six femoral components were cementless; all acetabular components were cementless with screws. Age at operation averaged 22.6 years. Two patients (3 hips) have died. Twelve hips in 9 patients have failed. Six cementless acetabular components with conventional polyethylene were revised because of osteolysis after 5.5 to 14.5 years. All 3 cementless C2 femoral stems with minimal porous coating failed. One of eight cemented AML Bantam stems loosened at 3.5 years; 2 of 23 cementless AML Bantam stems loosened at 9.5 and 19.6 years. Pain relief and functional improvement are dramatic after total hip arthroplasty in juvenile idiopathic arthritis; however, the long-term outcome is guarded.  相似文献   

19.
BACKGROUND: In recent studies, good intermediate-term results have been reported after primary hybrid total hip arthroplasty (a cementless acetabular component with a cemented femoral stem) for the treatment of primary osteoarthritis. However, few studies have described the results of this technique in patients with developmental dysplasia of the hip. METHODS: One hundred primary hybrid total hip replacements were performed in ninety patients to treat degenerative arthritis of the hip secondary to developmental dysplasia. Seventy-one patients (eighty-one hips) were available for clinical and radiographic evaluation. The average duration of follow-up was 10.6 years. There were ten men and sixty-one women. Seventy hips were classified as type 1 (dysplasia); seven, as type 2 (low dislocation); and four, as type 3 (high dislocation), according to the classification system of Hartofilakidis et al. RESULTS: At the time of the final follow-up, the average Harris hip score was 86 points. Structural autograft was used in fifteen hips to supplement acetabular coverage. Within five years postoperatively, the acetabular component in six of the fifteen hips had an average of 4.5 mm of vertical migration and an average increase in vertical rotation of 3 degrees, but the position appeared to stabilize thereafter. Revisions were performed in two hips because of recurrent dislocation. No acetabular or femoral component was revised because of aseptic loosening. Osteolysis was identified around two acetabular components and two femoral components. The average rate of polyethylene wear was 0.09 mm per year. CONCLUSIONS: Hybrid total hip arthroplasty for the treatment of symptomatic degenerative arthritis secondary to developmental dysplasia provides favorable results at intermediate-term follow-up. With lower grades of dysplasia, the majority of patients can be treated effectively without a structural bone graft by placement of the cementless acetabular component at a medial or high position.  相似文献   

20.
The authors studied the clinical and radiographic results of a modern titanium-alloy femoral stem with a cobalt-chrome-alloy head for use in cemented total hip arthroplasty. One hundred sixteen hips (102 patients) were operated on using modern cement techniques and prospectively followed using the Hospital for Special Surgery hip rating system and standard radiographic criteria. At a mean follow-up period of 4.8 years (range, 2–8 years), 69 hips were rated excellent, 38 good, 4 fair, and 5 poor. A total of 13 femoral components (11%) were radiographically loose according to the criteria of Harris. In 11 of these loose femoral components, debonding or separation at the cement-prosthesis interface, was the initial cause of failure, with bone-cement interface erosions occurring later in five hips. Revision of a loose femoral component has been performed in three hips and is pending in two other hips (4.3%). Significant calcar resorption was seen in only 17 hips (14.6%), and serial measurements of distal femoral cortical widths showed no distal cortical hypertrophy except in one femur. The incidence of loosening with this cemented titanium-alloy femoral component (with a cobalt-chrome-alloy head) is much higher than published reports of similar cobalt-chrome-alloy stems. The authors have abandoned the use of titaniumalloy femoral components for cemented total hip arthroplasty.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号