 共查询到18条相似文献,搜索用时 203 毫秒
1.
目的 比较AL-Scan、IOL-Master和A超测量白内障患者眼轴长度(axiallength, AL)的准确性和一致性。方法 选取年龄相关性白内障患者95例(142眼),术前分别应用AL-Scan、IOL-Master和A超进行AL测量。根据AL将患者分为AL≤22mm(20眼)、22mm<AL≤26mm(98眼)和AL>26mm(24眼)3组。应用方差分析对3种方法测量的结果进行比较,应用Bland-Altman法对其一致性进行分析。结果 AL≤22mm组AL-Scan、IOL-Master和A超测得AL结果分别为(21.53±0.30)mm、(21.54±0.29)mm及(21.51±0.30)mm,差异无统计学意义(P>0.05);22mm<AL≤26mm组分别为(23.68±0.76)mm、(23.71±0.77)mm及(23.65±0.75)mm,差异无统计学意义(P>0.05);AL>26mm组分别为(28.46±1.60)mm、(28.50±1.62)mm及(28.40±1.63)mm,差异无统计学意义(P>0.05)。AL测量的95%一致性界限范围是0.20mm(AL-Scan和IOL-Master)、1.12mm(IOL-Master和A超)和1.12mm(AL-Scan和A超)。结论 AL-Scan、IOL-Mas-ter和A超测量白内障患者AL同样准确,但AL-Scan与IOL-Master之间具有良好的一致性。  相似文献   

2.
目的 探讨准分子激光角膜原位磨镶术对患者的角膜曲率、前房深度及眼轴长度产生的影响。方法 准分子激光角膜原位磨镶术患者61例122眼,用光学相干生物测量仪(IOL-Master)分别测量术前及术后0.5a的角膜曲率、前房深度及眼轴长度,用电脑自动验光仪分别测量术前及术后0.5a的角膜曲率,对结果进行统计学分析比较手术前后各个参数的改变,用临床病史法计算出术后矫正角膜曲率(K矫正),建立K矫正对术后测量的角膜曲率(K术后)的回归公式,并比较IOL-Master和电脑自动验光仪测量术前和术后角膜曲率的一致性。结果 IOL-Master测量术前和术后的角膜曲率分别为(43.25±1.15)D和(39.13±1.92)D,前房深度分别为(3.65±0.21)mm和(3.55±0.20)mm,眼轴长度分别为(25.58±0.89)mm和(25.49±0.87)mm,手术前后三组数据相比差异均有统计学意义(均为P=0.000)。电脑自动验光仪测量的手术前后角膜曲率分别为(43.20±1.15)D和(39.06±1.89)D,推导的回归公式为:K矫正=1.093×K术后-4.013。Bland-Altman分析显示IOL-Master和电脑自动验光仪在测量术前和术后角膜曲率上一致性较好。结论 准分子激光角膜原位磨镶术后患者的角膜曲率、前房深度及眼轴长度均较术前降低,相比较角膜曲率改变更明显,可采用回归公式对术后角膜曲率进行矫正。IOL-Master和电脑自动验光仪在测量术前和术后角膜曲率上一致性较好,临床上可以替代使用。  相似文献   

3.
目的 评价用IOLMaster和SRK-Ⅱ、SRK-T、Holladay-1和Haigis四种公式计算眼轴≥27mm的高度近视眼人工晶状体(intraocularlens,IOL)度数的准确性。方法 回顾性分析于我院行白内障超声乳化摘出联合IOL植入术、眼轴≥27mm的高度近视合并白内障患者105例(148眼)的临床资料,用IOLMaster测量并用以上四种公式计算IOL度数和预测术后屈光度。按照眼轴长度分组,从27mm起每增加1mm为一组,分别计算各组术后3个月时实际术后等效球镜度(actualpostoperativesphericalequivalence,APSE)与四种公式计算的预测术后等效球镜度(predictedpostoperativesphericalequivalence,PPSE)的差值,即为预测屈光度误差值(predictiveerror,PE)。比较四种公式在不同眼轴长度区间PE的统计学差异,将眼轴组间PE没有统计学差异的组合并得到眼轴长区间,并计算出这四种IOL计算公式在不同眼轴长度区间的PE。结果 148眼眼轴长度为(31.06±2.32)mm,PE在SRK-Ⅱ、SRK-T、Holladay-1和Haigis公式分别为(1.01±1.53)D、(0.76±0.96)D、(1.24±0.80)D和(0.78±0.84)D;四种公式计算的PPSE与APSE间差异均有统计学意义(均为P<0.05),SRK-T和Haigis公式的PE差异无统计学意义(P>0.05);Holladay-1公式的PE与SRK-T、Haigis公式的PE均有显著差异(均为P<0.05)。将眼轴组间PE没有统计学差异的组合并后得到27~30mm、30~32mm、32~34mm、≥34mm四个眼轴长度区间,SRK-T/Haigis公式在各区间的PE分别为(0.21±0.65)D/(0.48±0.71)D、(0.58±0.56)D/(0.58±0.61)D、(1.18±0.67)D/(0.97±0.61)D和(1.97±1.44)D/(1.76±1.26)D。结论 在眼轴≥27mm的高度近视眼IOL度数计算上SRK-Ⅱ、SRK-T、Haigis和Holladay-1公式预测术后屈光度均为近视方向的过矫正。在不同眼轴长度区间用SRK-T/Haigis公式计算时,适当向近视方向调整PPSE(-0.2~-2.0)/(-0.5~-1.8)D而得到的植入IOL度数可以改善计算公式的准确性。  相似文献   

4.
目的 探讨中老年白内障患者眼生物学参数分布状况及变化规律。方法 选取2012年7月至2013年7月于我院住院手术治疗的40岁以上白内障患者1861例,应用IOLMaster测量仪测量眼轴(axiallength,AL)、前房深度(anteriorchamberdepth,ACD),对结果进行统计分析。结果 1861例白内障患者AL均值为23.19mm(95%可信区间为23.15~23.23mm),ACD均值为3.14mm(95%可信区间为3.12~3.16mm),男性AL、ACD均大于女性,差异均有统计学意义(均为P<0.05);AL、ACD随着年龄的增长而减小或变浅(均为P<0.001)。结论 AL、ACD随着年龄的增长而递减,应用IOL-Master测量仪测量白内障患者的眼生物学参数结果可以反映正常人群的眼解剖参数参考范围及变化趋势。  相似文献   

5.
目的 比较A超与光学相干生物测量仪(IOLMASTER)测量低信噪比(signaltonoiseratio,SNR)高度近视眼人工晶状体(intraocularlens,IOL)度数的精确性。方法 对2015年3月至2016年2月间在我院行白内障超声乳化联合IOL植入手术并且眼轴长度大于26mm的高度近视患者57例(69眼)进行回顾性研究。SNR≤2组11眼、SNR>2~5组23眼、SNR>5~10组20眼,无法用IOLMASTER检出的病例设为A超测量组15眼。分别用IOLMASTER或接触式A超测算度数,计算公式采用HOLLADAY-1公式,并按各自方法植入同一类型IOL,术后3个月分别计算各组的平均绝对屈光误差值。结果 SNR>5~10组、SNR>2~5组、SNR≤2组、A超测量组的绝对屈光误差值分别为(0.44±0.18)D、(0.46±0.26)D、(0.69±0.22)D、(0.81±0.29)D,其中SNR>2~5组及SNR>5~10组分别与其他2组比较,差异均有统计学意义(均为P<0.05),而SNR>2~5组与SNR>5~10组以及SNR≤2组与A超测量组之间差异均无统计学意义(均为P>0.05)。结论对于低SNR的高度近视眼患者,采用IOLMASTER测算IOL度数比传统A超方式具有更高的精确性。  相似文献   

6.
目的 应用IOL-Master通过不同人工晶状体计算公式,分析轴性高度近视眼患者行白内障手术后目标屈光和实际屈光的符合程度,评价不同人工晶状体计算公式的准确度。方法 收集2013年1月至2014年4月在我院行白内障手术的轴性高度近视患者66例(100眼),将其按眼轴长度(axiallength,AL)分为三组,组1为26mm≤AL<28mm(54眼),组2为28≤AL<30mm(28眼),组3为AL≥30mm(18眼);按角膜曲率(K)分为四组,组1为≤42.00D(17眼),组2为>42.00~44.00D(27眼),组3为>44.00~46.00D(48眼),组4为>46.00D(8眼)。术前均采用Haigis、SRK/T、HolladayI及HofferQ公式进行人工晶状体度数计算。应用IOL-Master的部分相干干涉测量(partialcoherenceinterferometry,PCI)技术计算人工晶状体度数。分析Haigis、SRK/T、HolladayI及HofferQ四种计算公式所预估的术后目标屈光度与术后6个月的实际屈光度符合程度。结果 按AL分组,组1中,四种公式对术后实际屈光的预测准确度一样,四种方法之间比较,差异无统计学意义(P>0.05);组2中,SRK/T公式的目标屈光与实际屈光的差值最小,准确度最高,四种方法之间比较,差异有统计学意义(P<0.05);组3中,Haigis公式的目标屈光与实际屈光的差值最小,准确度最高,四种方法之间比较,差异有统计学意义(P<0.05)。按角膜曲率分组,各组中四种方法之间比较,差异无统计学意义(P>0.05)。结论 利用IOL-Master对长眼轴进行人工晶状体度数计算时,Haigis公式具有相对稳定的准确度,而随着患者眼轴的增加,准确度逐渐下降。  相似文献   

7.
郭琳  马波 《眼科新进展》2014,(9):868-871
目的 比较年龄相关性白内障患者术前IOLMaster、角膜地形图及Pentacam测量角膜散光各参数的差异。方法 收集我院年龄相关性白内障患者56例(67眼),术前分别通过IOLMaster、角膜地形图及Pentacam测量平坦子午线角膜屈光力即最小角膜曲率(flatkeratometry,Kf)、陡峭子午线角膜屈光力即最大角膜曲率(steepkeratometry,Ks)、平均角膜曲率(meankera-tometry,Km)、散光度参数J0(cylinderat0-degreemeridian)及轴向参数J45(cylinderat45-degreemeridian);采用配对t检验对三组测量结果的差异进行比较,不同测量仪器所得的数据的相关性采用Pearson相关性分析,三种方法测量结果的一致性采用Bland-Altman分析。结果 IOLMaster测量Kf、Ks、Km、J0、J45分别为(43.524±1.751)D、(44.352±1.839)D、(43.938±1.753)D、(0.059±0.455)D、(0.264±0.228)D;角膜地形图所测Kf、Ks、Km、J0、J45分别为(43.404±1.740)D、(44.290±1.843)D、(43.847±1.753)D、(0.046±0.453)D、(0.242±0.222)D;Pentacam所测Kf、Ks、Km、J0、J45分别为(43.401±1.739)D、(44.285±1.838)D、(43.843±1.751)D、(0.047±0.456)D、(0.241±0.221)D;IOLMaster和角膜地形图及Pentacam的检测结果比较差异均有统计学意义(均为P<0.05),角膜地形图及Pentacam检测结果比较差异无统计学意义(P>0.05);Pearson相关分析显示,Kf、Ks、Km、J0、J45等5个指标在三种检查仪器检测结果之间均有高度的正相关性(均为P<0.001)。Bland-Altman一致性分析说明三种仪器的检测结果具有较好的一致性。结论 IOLMaster、角膜地形图及Pentacam均可以应用于年龄相关性白内障患者术前测量角膜散光的各项参数。  相似文献   

8.
目的 对比分析CirrusHD-OCT和A超测量中央角膜厚度的差异性及相关性,并探索CirrusHD-OCT角膜测厚与眼轴长度的关系。方法 回顾性研究2015年1月至4月拟在我院行角膜激光矫正近视手术的患者42例(84眼),按眼轴长度分为三组,A组(32眼):眼轴长度24~26mm组;B组(31眼):眼轴长度>26~28mm组;C组(21眼):眼轴长度>28mm组。利用CirrusHD-OCT和A超分别测量患者的中央角膜厚度,用配对t检验来比较两种方法测厚的差异性,用Pearson分析两种方法测厚的相关性,用两独立样本t检验比较不同眼轴组角膜厚度的差异性。结果 A组CirrusHD-OCT和A超测量患者的中央角膜厚度分别为(539.91±30.74)μm和(540.22±30.79)μm,测量结果差异无统计学意义(t=0.230,P>0.05)。B组CirrusHD-OCT和A超测量患者的中央角膜厚度分别为(543.94±31.75)μm和(544.36±33.58)μm,测量结果差异无统计学意义(t=0.304,P>0.05)。C组CirrusHD-OCT和A超测量患者的中央角膜厚度分别为(548.19±25.81)μm和(545.43±26.70)μm,测量结果差异也无统计学意义(t=1.766,P>0.05)。CirrusHD-OCT和A超测量结果具有显著正相关性(r=0.97,P<0.05)。三组间CirrusHD-OCT角膜测厚的差异性比较,A组与B组测量值差异无统计学意义(t=0.504,P>0.05)、A组与C组测量值差异无统计学意义(t=0.999,P>0.05)、B组与C组测量值差异无统计学意义(t=0.499,P>0.05)。CirrusHD-OCT测量角膜厚度与眼轴长度无相关性。结论 CirrusHD-OCT测量中央角膜厚度结果可靠,且CirrusHD-OCT和A超的测量结果显著的正相关。CirrusHD-OCT角膜测厚与眼轴长度无关。  相似文献   

9.
目的 对比植入非对称区域折射型多焦点人工晶状体(multifocalintraocularlens,MIOL;SBL-3)与可调节型IOL(ac-commodatingIOL,AIOL;TetraflexHD)后的视觉质量。方法 前瞻性队列研究。选取在我院诊断为单纯性白内障,并行白内障超声乳化联合IOL植入术的患者26例(38眼)为研究对象,其中植入SBL-3MIOL者18眼为MIOL组,植入TetraflexHDAIOL者20眼为AIOL组。术后1个月、3个月分别检查患者裸眼远、近视力,最佳矫正远、近视力及远视力矫正下近视力,3个月时使用视觉质量分析系统评估患者斯特列尔比率、调制传递函数截止频率(MTFcutoff)值及客观调节幅度。采用SPSS18.0分析数据。结果 术后3个月时两组患者间裸眼远视力及最佳矫正远、近视力差异均无统计学意义(均为P>0.05);MIOL组裸眼近视力及远视力矫正下近视力分别为(0.245±0.079)logMAR、(0.279±0.074)logMAR,均优于AIOL组的(0.303±0.094)logMAR和(0.339±0.077)logMAR,差异均有统计学意义(均为P<0.05);术后3个月时,视觉质量分析系统测得MIOL组和AIOL组斯特列尔比率值分别为0.19±0.29和0.15±0.05,客观调节幅度分别为(2.72±0.49)D和(2.19±0.49)D,两组相比差异均有统计学意义(均为P<0.05)。结论 非对称区域折射型MIOL与AIOL在视觉质量方面具有差异性。  相似文献   

10.
目的 探讨后巩膜加固术治疗硅油填充术后复发性超高度近视黄斑裂孔性视网膜脱离(macularholeretinaldetachment,MHRD)的可行性及疗效。方法 选取2011年6月至2014年6月硅油填充术后的复发性超高度近视性MHRD患者36例(36眼),所有患者均由同一术者行黄斑区改良后巩膜加固术,术后3个月取出硅油。术后随访12个月,观察记录术后并发症、视网膜脱离复位情况、黄斑裂孔闭合情况、术后视力、眼轴长度等指标。结果 36眼视网膜完全复位,视网膜复位率为100%;末次随访SD-OCT示22眼黄斑裂孔完全闭合,占61.1%,11眼黄斑部分闭合,占30.6%,3眼仍未闭合,占8.3%;31眼术后最佳矫正视力(bestcorrectvisualacuity,BCVA)较术前提高,占86.1%,5眼BCVA较术前无明显改变,占13.9%;术前患者BCVA为(1.48±0.92)logMAR,术后BCVA为(0.93±0.38)logMAR,差异有统计学意义(P<0.05);术前患者眼轴长度为(30.95±1.16)mm,术后为(28.46±1.34)mm,差异有统计学意义(P<0.001)。所有患眼均未发生眼底出血、眼内炎、涡静脉回流障碍、眼前部缺血综合征等并发症。结论 改良后巩膜加固术是治疗硅油填充术后复发性超高度近视MHRD安全有效的手术方法,能提高视网膜解剖复位率、黄斑裂孔闭合率、视力及减少并发症。  相似文献   

11.
目的 明确有晶状体眼后房型人工晶状体(ICL)植入术术前及术后眼轴长度在不同设定条件下是否存在差别,由此确定术后眼轴测量的方式,为ICL术后发生的白内障进行人工晶状体测算提供指导.方法 选取自2008年5月至2009年12月间于中国医科大学眼科医院行ICL植入术患者70例(135只眼),年龄21~48岁,于术前1周及术后3个月分别行IOL-Master、A超测量眼轴长度.并设定IOL-Master测量方式为正常眼(即phakic眼)及人工晶体眼(Pseudophakic PMMA)模式,A超为正常眼及特殊眼模式,其中特殊眼晶体声速设为1555 m/s.将所得数据进行统计学分析,术前术后各变量采用配对样本t检验,结果术前以IOL-Master测量眼轴长度平均为(28.02±0.22)mm,A超测量眼轴长度平均为(27.81±0.22)mm;术后以IOL-Master正常眼模式及Pseudophakic PMMA 模式测量眼轴长度平均值分别为:(28.01±0.22)及(28.12±0.22)mm;术后以A超正常眼模式及特殊眼模式测量眼轴长度平均值分别为(27.82±0.22)、(26.40±0.21)mm.术前采用A超及IOL-Master测量眼轴,两者比较差异有统计学意义(t=9.722,P=0.000);术前采用A超,而术后IOL-Master Phakic模式及Pseudophakic PMMA模式测量眼轴,与术前相比差异均有统计学意义(t=-9.058,-14.646;P=0.000);术前采用IOL-Master,术后采用A超正常眼及特殊眼模式下的测量的结果与术前比较,差异均有统计学意义(t=10.832,61.470;P=0.000).结论 有晶状体眼后房型人工晶状体植入后对眼轴长度的测量根据选择测量方式的不同较之术前有一定的变化.建议有晶状体眼后房型人工晶状体植入矫正高度近视眼术前及术后对眼轴的测量尽量采用.IOL-Master正常眼模式,如因白内障造成IOL-Master测量困难,则应采用A超正常模式测量眼轴.
Abstract:
Objective To definitute axial length measuring mode of the phakic eyes after posterior chamber implantation of lens. Methods All patients came from the Ophthalmology Hospital of China Medical University . Seventy patients with 135eyes,aged 21-48 years old. Among this group 28 were male,53eyes;42 were female, 82 eyes. A-ultrasound and IOL-Master was used to measure axial length one week before preoperative and three months after ICL implantation. There are two measuring mode in A-ultrasound and IOL-Master: normal and special. All the results were analysed by the SPSS11.5 statistical methods.Results (1) preoperative AXL of A-ultrasound and IOL-Master average are: (27.81 ±0.22) mm,(28. 02 ±0.22) mm; (2) postoperative AXL of phakic and Pseudophakic PMMA mode of IOL-Master average are: (28.01 ±0. 22) mm, (28. 12 ±0.22)mm; (3) postoperative AXL of normal and special mode of A-ultrasound average are: (27. 82 ± 0. 22 ) mm, ( 26. 40 ± 0. 21 ) mm. Conclusion According to the different meansuring mode, there are some difference of AXL between the preoperative and postoperative ICL.The more accurately meansuring mode is IOL-Master phakic mode before and after operation. A-ultrasound normal mode can be used if the lens become so turbid that the AXL can't be obtained by IOL-Master.  相似文献   

12.
Purpose: A comparison of axial length estimates using applanation A‐scan ultrasound and the Zeiss IOLMaster was conducted. The accuracy in predicting postoperative refraction determined by each method was also compared. Methods: A cross‐sectional study was performed on 51 eyes in 46 patients presenting to clinical practice for cataract surgery assessment. Preoperative measurement of axial length was performed with applanation ultrasound and the IOLMaster. The IOLMaster measurements were used to determine the intraocular lens power based on the SRK/T formula. Postoperative refractive outcomes were obtained and spherical equivalent calculated and compared to the predicted refractive error with each biometric method. Results: On average the axial lengths measured by the IOLMaster were longer by 0.15 mm compared to ultrasound biometry (P < 0.01). Using the IOLMaster over applanation ultrasound biometry significantly improved the postoperative refractive outcome from 0.65 D to 0.42 D (P = 0.011). Conclusions: The IOLMaster provides an accurate axial length measurement and results in accurate intraocular lens power calculation based on the SRK/T formula. It is quick and easy to use and provides a non‐contact technique with no risk of infection or corneal abrasion.  相似文献   

13.
AIM: To evaluate the accuracy of segmented measurement of axial length (AL) in high myopia filled with silicone oil by immersion B-scan ultrasonography (immersion B-scan). METHODS: From June 2016 to June 2020, a total of 67 ultra-high myopia inpatients (67 eyes) who underwent silicone oil removal combined with cataract extraction and intraocular lens (IOL) implantation were retrospectively enrolled. The preoperative axial length (AL) of 31 patients with severe cataract were segmented measured using immersion B-scan (B-scan group) and another 36 patients with mild or moderate cataract were measured using IOLMaster 500 (IOLMaster group). The post-operative ALs in two groups were both measured using IOLMaster 500. The IOL power was calculated with Haigis formula. The differences in ALs between pre- and post-surgery, as well as the postoperative refractive spherical equivalent, absolute refractive error, the prediction deviation of postoperative refraction and best corrected visual acuity (BCVA) were compared. RESULTS: The pre- and post-operative ALs were 30.46±1.63 mm (range 28.09-33.51 mm) and 30.42±1.70 mm (range 28.03-33.90 mm) in B-scan group (t=0.644, P=0.542) and 30.51±1.21 mm (range 28.03-33.90 mm) and 30.43±1.27mm (range 28.54-33.50 mm) in IOLMaster group (t=1.843, P=0.074), respectively. Three months after surgery, BCVA were 0.45±0.13 (range 0.3-0.9) and 0.44±0.20 (range 0.2-1.0) in B-scan and IOLMaster group respectively (t=0.086, P=0.932). There was no significant difference of the postoperative spherical equivalent (-3.11±0.65 D vs -3.21±0.51 D, t=0.671, P=0.505) and the absolute refractive error (0.589±0.340 vs 0.470±0.245 D, t=1.615, P=0.112) between two groups. In B-scan group, absolute refractive error within ±0.50 D was found in 18 eyes (58.1%), within ±1.00 D in 26 eyes (83.9%), and within ±1.50 D in 31 eyes (100%). In IOLMaster group, absolute refractive error within ±0.50 D was found in 23 eyes (63.9%), within ±1.00 D in 34 eyes (94.4%), and within ±1.50 D in 36 eyes (Z=0.757, P=0.449). CONCLUSION: The segmented measurement of ALs by immersion B-scan shows comparable measurement accuracy with that of IOLMaster 500 in ultra-high myopia patients with severe cataract secondary to silicone oil filling and can obtain an ideal postoperative refractive state.  相似文献   

14.
目的:比较CarlZeiss IOL-Master与传统生物测量方法在测量无晶状体眼患儿眼轴长度的准确性。方法:术前分别应用传统超声生物测量方法,自动电脑验光仪及IOL-Master测量眼轴长度及角膜曲率。按超声方法测量结果计算植入人工晶状体的屈光度。利用IOL-Master测量结果计算其预测屈光误差。术后1mo检查患者的屈光状态。结果:当眼轴≤26mm时,IOL-Master测得的眼轴均值为(23.28±0.63)mm,接触式A超测量的眼轴均值为(23.24±0.64)mm,两者之间比较差异无显著性意义。当眼轴>26mm时,IOL-Master测得的眼轴均值为(26.48±0.35)mm,接触式A超测量的眼轴均值为(26.68±0.38)mm,两者之间比较差异有显著性意义(P<0.01)。IOL-Master测得的角膜曲率为(44.42±1.18)D,自动验光仪测得的角膜曲率为(44.40±1.25)D,两者之间比较差异无显著性意义。当眼轴≤26mm时,术后实际屈光度为(-0.28±0.36)D,IOL-Master组预计术后屈光度为(-0.39±0.53)D,传统生物测量方法组预计术后屈光度(-0.25±0.15)D,各组之间比较差异无显著性意义。当眼轴>26mm时,术后实际屈光度为(0.38±0.18)D,IOL-Master组预计术后屈光度为(0.43±0.24)D,传统生物测量方法组预计术后屈光度为(-0.05±0.07)D,实际屈光度与IOL-Master预计术后屈光度两者之间比较差异无显著性意义,实际屈光度与传统生物测量方法组的预计术后屈光度两者之间比较差异有显著性意义(P<0.01)。结论:无晶状体眼患儿进行眼轴测量时,IOL-Master有非接触、高准确、操作简便等优点,另外对无晶状体眼的高度近视患儿IOL-Master测量的准确性高,在一些特殊情况仍需依赖于传统接触式A超测量。  相似文献   

15.
目的 探讨IOL-Master测量硅油填充眼眼轴长度可行性以及其计算晶状体度数的精确性.方法 选择2007年6月至2008年12月间在本院行玻璃体切割联合眼内硅油填充术3~6个月后,行白内障摘除人工晶状体植入联合硅油取出术的患者,共78例,83只眼.术前行IOL-Master测量眼轴长度,并将测量值用SRK/Ⅱ公式计算出人工晶状体度数.术后1周行接触式A超,术后3个月行IOL-Master复测眼轴长度.术后3月综合验光仪行主觉验光.结果 眼轴长度测量结果术前IOL-Master与术后A超及IOL-Master分别比较,差异无统计学意义(P=0.505,0.065),但是术后A超与IOL-Master测量结果差异有统计学意义(P=0.012).术后3个月绝对屈光误差≤0.5D共73只眼,占88.0%;>0.5D共10只眼,占12.0%.结论 IOL-Master对于硅油填充眼的眼轴长度测量具有较好可信性,其计算人工晶状体度数预测性高.  相似文献   

16.
周健  周玲  吴玉丽  胡丹  惠延年 《眼科学报》2000,16(4):270-275
目的观察儿童白内障摘除及人工晶状体植入后眼球及屈光状态的变化,探讨屈光状态变化的原因.方法测量10例(12只眼)白内障患儿术前及术后(指本次随访时)的眼球轴长、角膜曲率及术后角膜顶点到人工晶状体前表面顶点的距离(The distance from the vertex of the cornea to the anterior vertex of intraocularlens AVpc),比较术眼在手术前后的变化及与对照眼(未手术的对侧眼)在术前、术后的差异.在术后两周内及本次随访时检影,观察其人工晶状体眼屈光状态的变化.患儿手术时年龄7.16±1.94岁,随访时间平均35.8月(23~48月).结果术眼(n=12)眼轴长在术后平均增加0.39±0.48 mm;对照眼(n=8)轴长增加0.66±0.68mm.术眼、对照眼在手术后眼轴长的增加均有显著的统计学意义(P<0.05),而术眼与对照眼的轴长增加量之间无显著性差异(P>0.05).术眼、对照眼的角膜曲率在手术前后分别比较、双眼之间比较均无显著性差异(P>0.05).术后测量的AVpcl为3.83±0.58 mm,而估算的AVpc2为4.663 0±0.224 2 mm,两者之间有显著的统计学差异(P<0.01),提示人工晶状体在眼内的位置前移0.832 0±0.744 1 mm.根据手术前后眼轴长和角膜曲率值,按照SRKⅡ公式估算,在本次随访时人工晶状体眼有-1.53±1.70 D(n=12,P<0.01)的屈光变化;而实际检影结果却有-3.86±2.48 D(n=9,P<0.05)的变化;估计量与实际量之间有显著的统计学差异(P<0.05).结论在儿童期行白内障摘除及人工晶状体植入不影响眼球的生长,由于眼轴长度的增加及并发症引起人工晶状体在眼内的位置前移可能引起人工晶状体眼向近视状态变化,所以,在决定植入儿童眼内的人工晶状体度数时应在正视度数上适当减少度数,以求得人工晶状体眼在远期获得正视或轻度近视状态.眼科学报2000;16270~275.  相似文献   

17.
王铀  龚凌  姜德咏 《国际眼科杂志》2013,13(11):2343-2345
目的:比较评估A超及IOL Master在硅油眼患者眼轴长度测量的精确性,探讨IOL Master在硅油眼人工晶状体度数计算中的临床应用价值。方法:分析我院2012-06/12间收治的硅油眼白内障手术患者30例30眼,分别用接触式A超及IOL Master测量术前、术后眼轴长度比较两者之间差异。并将术前IOL Master测量自动获取IOL度数后预估患眼屈光状态与术后1mo复查患者屈光状态(等效球镜度数)行统计学分析。结果:A超与术前IOL Master测量眼轴有显著性差异,使用IOL Master测量术前、术后眼轴无显著差异,术后使用A超及IOL Master测量眼轴之间无显著性差异。采用IOL Master术前测量眼轴所得人工晶状体度数植入人工晶状体术后屈光状态与术前预估无明显差异。结论:IOL Master测量眼轴较A超有明显优越性,但对于某些不能使用IOL Master测量的病例仍需结合A超等其他测量方法辅助测量。  相似文献   

18.
目的分析高度近视眼应用SRK/T公式与优化Haigis公式计算人工晶状体(IOL)度数对白内障术后屈光误差的分布情况及影响因素,探讨2种公式的精确度。方法回顾性研究。选取2011年7月至2015年3月来温州医科大学附属眼视光医院行手术治疗,眼轴长度(AL)≥26 mm的高度近视白内障患者38例(63眼)。术前用IOLMaster检查AL、角膜屈光力(K)、前房深度(AC),应用SRK/T公式及优化Haigis公式计算IOL度数,术中植入单焦点可折叠IOL,术后3个月或3个月以上进行主觉验光。2种公式术后屈光误差值比较采用配对资料t检验,远视偏移比例比较采用McNemar配对检验,绝对误差值(AE)分布比较采用Wilcoxon秩和检验,对2种公式预留度数的差值及AE与AL、K及AC进行Peason相关分析,对2种公式误差值的影响因素进行多因素线性回归分析。结果SRK/T公式及优化Haigis公式术后平均屈光误差值分别为(-0.52±0.79)D与(-0.67±0.79)D,远视偏移比例分别为78%与86%。2种公式预留度数的差值与AL呈负相关关系(r=-0.27,P<0.05),与K呈正相关关系(r=0.73,P<0.01)。2种公式AE与AL呈正相关关系(SRK/T:r=0.43,P<0.01;优化Haigis:r=0.31,P<0.05)。AC≤3.5 mm时,SRK/T公式与优化Haigis公式屈光误差值直线回归方程分别为■=3.74-0.15AL(R2=0.27,F=3.88,P<0.05)与■=12.03-0.19K-0.13AL(R2=0.27,F=3.73,P<0.05);AC>3.5 mm时,SRK/T公式与优化Haigis公式屈光误差值直线回归方程分别为■=1.40AC-0.37AL(R2=0.62,F=13.40,P<0.01)与■=14.02+1.76AC-0.25K-0.35AL(R2=0.62,F=13.59,P<0.01)。结论对于AL较长者,SRK/T远视偏移更明显,优化Haigis公式优于SRK/T公式。对于角膜曲率较大者,优化Haigis公式术后屈光远视偏移误差增大,SRK/T公式优于优化Haigis公式。当AC>3.5 mm,2种公式可适量减少预留近视度数。  相似文献   