BACKGROUND: The electrocardiogram (ECG) patterns during pacing from the great cardiac vein (GCV) and the middle cardiac vein (MCV) are not well known. METHODS: We recorded 12-lead ECGs during GCV and MCV pacing in 26 patients undergoing implantation of a cardiac resynchronization device. The left ventricular (LV) lead was passed down the GCV (n = 19) or MCV (n = 7) prior to moving it to a lateral or posterolateral vein for permanent implantation. RESULTS AND CONCLUSIONS: Pacing within the GCV resulted in a left bundle branch block (LBBB) morphology with no or minimal R-wave in V(1) in 14 patients and a right bundle branch block (RBBB) pattern (R > S in lead V(1)) in four patients. In one patient, lead V1 during GCV pacing was isoelectric (R = S). A more distal pacing site in the GCV yielded a LBBB pattern in all the patients. All leads placed in the MCV resulted in a LBBB configuration. An ECG pattern with a RBBB pattern was invariably recorded during LV pacing in 125 consecutive outpatients with biventricular pacemakers and LV leads in the posterolatral and lateral coronary veins. Knowledge of the ECG patterns from various pacing sites in the coronary venous system may be helpful for troubleshooting all types of pacing systems, especially those where the coronary venous pacing site is unintentional.  相似文献   

2.
Recently the use of alternate site pacing to improve cardiac function in patients with bradyarrhythmias has increased. In the present study, hemodynamics of right ventricular septal pacing were studied in seven dogs. A bipolar screw-in lead and endocardial lead were placed in the proximal right ventricular septum and right ventricular apex, respectively. The right ventricle was paced from each site. A conductance catheter and Millar catheter were inserted into the left ventricle to determine the left ventricular pressure and the pressure-volume loop. Cardiac output was measured using the thermodilution method. In five of the seven dogs, ventricular activation was documented by isochronal epicardial activation mapping during each pacing mode. Mean arterial pressure and cardiac output during septal pacing were significantly higher than during apical pacing (110 +/- 17 mmHg vs 100 +/- 18 mmHg; 1.00 +/- 0.39 L/min vs 0.89 +/- 0.33 L/min). The positive dp/dt during septal pacing was significantly higher than during apical pacing (2137 +/- 535 mmHg/s vs 1911 +/- 404 mmHg/s). End-systolic elastance during septal pacing was significantly higher compared to apical pacing (13.1 +/- 0.3 mmHg/mL vs 8.9 +/- 4.0 mmHg/mL). The ventricular activation time during septal pacing was significantly shorter than during apical pacing. The epicardial maps generated during septal pacing were similar to those from atrial pacing. We conclude that hemodynamics and interventricular conduction are less disturbed by proximal right ventricular septal pacing than apical pacing in dogs with normal hearts.  相似文献   

3.
Ventricular activation onset-triggered (VAOT) left ventricular pacing modalities synchronize left ventricular paced activation with existing intrinsic ventricular activation, in patients with complete LBBB and adequate rate. The purpose of this study was to evaluate the safety and feasibility of VAOT pacing with one left ventricular pacing lead, during temporary pacing in the postoperative period following open heart surgery. VAOT pacing was studied in five patients with LBBB and two patients with previously implanted right ventricular pacemakers. The VAOT pacing system used was assembled by modifying the function of existing equipment and its programming is described in detail. Comparative ECGs are reported, documenting the changes in ventricular activation produced by VAOT pacing. Stability of surface ECG acquisition was found to be essential to the success of temporary VAOT pacing and inappropriate pacing due to ECG instability is described. Patients were studied at rest and none experienced congestive heart failure. In the comparison of cardiac output, with and without VAOT pacing, no significant differences were found in LBBB patients or those with right ventricular pacemakers. In the comparison of arterial pressure, with and without VAOT pacing, no significant differences were found in six patients, however, in one LBBB patient with intrinsic predominant ventricular trigeminy, VAOT pacing was observed to have an antiarrhythmic effect resulting in suppression of ventricular ectopy and stabilization of arterial pressure. All patients survived VAOT pacing and the postoperative period without complications requiring additional intervention or treatment. (PACE 2004; 27[Pt. I]:730–739)  相似文献   

4.
The right ventricular apex has been used as the traditional pacing site since the development of transvenous pacing in 1959. Some studies suggest that pacing the right ventricular apex may cause remodeling and is harmful. In the past decade, there have been a multitude of studies of the hemodynamic, electrophysiological, electrocardiographic, and clinical effects of ventricular pacing at other sites. Pacing of the left ventricle singly or with biventricular pacing has emerged as an effective and safe therapy for moderate to severe congestive heart failure in patients with prolonged QRS complexes. Studies of alternate right ventricular sites, like the right ventricular outflow tract, have given mixed results. Not all patients can be treated with left ventricular pacing, which is a time-consuming and difficult procedure. Right ventricular pacing is easier and less expensive than left ventricular pacing and further study of additional right ventricular sites seems warranted. (PACE 2004; 27[Pt. II]:871–877)  相似文献   

5.
Background: Biventricular (BiV) pacing and left ventricular (LV) pacing both improve LV function in patients with heart failure and LV dyssynchrony. We studied the hemodynamic effect of the atrioventricular (AV) interval and the associated changes in the right ventricular (RV) electrogram (EGM) during LV pacing and compared this with the hemodynamic effect of optimized sequential BiV pacing.
Methods: In 16 patients with New York Heart Association (NYHA) class II to IV, sinus rhythm with normal AV conduction, left bundle branch block (LBBB), QRS > 130 ms, and optimal medical therapy, the changes in RV EGM during LV pacing with varying AV intervals were studied. The hemodynamic effect associated with these changes was evaluated by invasive measurement of LVdP/dtmax and compared with the result of optimized sequential BiV pacing in the same patient.
Results: All patients showed electrocardiographic fusion during LV pacing. The morphology of the RV EGM showed changes in the RV activation that indicated a shift in the extent of fusion from LV pacing. These changes were associated with significant changes in LVdP/dtmax. Baseline LV dP/dtmax was 734 ± 177 mmHg/s, which increased to 927 ± 202 mmHg/s (P<0.0001) with optimized LV pacing and to 920 ± 209 mmHg/s (P<0.0001) with optimized sequential BiV pacing.
Conclusion: The RV EGM is a proper indicator for intrinsic activation over the right bundle during LV pacing and reveals the transition to fusion in the RV EGM that is associated with a decrease in LVdP/dtmax. The hemodynamic effect of optimized LV pacing is equal to optimized sequential BiV pacing.  相似文献   

6.
Left ventricular and biventricular pacing in congestive heart failure   总被引:3,自引:0,他引:3  
Dual-chamber pacing improved hemodynamics acutely in a subset of patients with left ventricular (LV) dysfunction but conveyed no long-term symptomatic benefit in most. More recently, LV pacing and biventricular (multisite) pacing have been used to improve systolic contractility by altering the electrical and mechanical ventricular activation sequence in patients with severe congestive heart failure (CHF) and intraventricular conduction delay or left bundle branch block (LBBB). Intraventricular conduction delay and LBBB cause dyssynchronous right ventricular and LV contraction and worsen LV dysfunction in cardiomyopathies. Both LV and biventricular cardiac pacing are thought to improve cardiac function in this situation by effecting a more coordinated and efficient ventricular contraction. Short-term hemodynamic studies have shown improvement in LV systolic function, which seems more pronounced with monoventricular LV pacing than with biventricular pacing. Recent clinical studies in limited numbers of patients suggest long-term clinical benefit of biventricular pacing in patients with severe CHF symptoms. Continuing and future studies will demonstrate whether and in which patients LV and biventricular pacing are permanently effective and equivalent and which pacing site within the LV produces the most beneficial hemodynamic results.  相似文献   

7.
BACKGROUND: Cardiac resynchronization therapy (CRT) has been introduced as a new therapeutic modality in patients with chronic heart failure. However, most studies have investigated the hemodynamic effects in congestive, but not postoperative heart failure. OBJECTIVE: The following study investigates hemodynamic effects of perioperative temporary biventricular pacing in patients undergoing open heart surgery.In 54 patients one left and one right ventricular epicardial wire was placed during open heart operations. Hemodynamic parameters were measured immediately after the operation and 6 as well as 24 hours postoperatively. Transesophageal echocardiography was performed 1 hour postoperatively. RESULTS: Of the 54 patients (59.2%), 32 responded to biventricular pacing with an increase in cardiac output; in these patients synchronized ventricular contraction could be verified echocardiographically. This hemodynamic benefit persisted 6 hours and 24 hours postoperatively. The remaining 22 patients did not show any hemodynamic improvement from biventricular stimulation. CONCLUSION: Biventricular pacing leads to significant rise in cardiac output in approximately 59% of patients with severely reduced left ventricular function and widened QRS complexes. Further studies are necessary to define clearly the clinical characteristics of patients who show remodeling by CRT.  相似文献   

8.
Controversy exists as to whether short AV delay pacing is beneficial in left ventricular dysfunction with the studies performed coming to disparate conclusions. The right ventricular apical pacing previously studied results in asynchronous contraction and relaxation sequences and may limit the potential benefits of short AV delay pacing. In this study the hemodynamic effects of septal (resulting in a more physiological activation sequence) and apical right ventricular activation were compared in 15 patients with heart failure. VDD pacing with AV delays of 50,100, and 150 msec was evaluated. Apical VDD pacing did not increase the cardiac output significantly, 4.1 ± 0.75 to 4.45 ± 0.74 L/min, whereas septal VDD pacing increased the cardiac output to 4.86 ± 0.79 L/min (P = 0.037). Apical pacing increased the cardiac output in 10 patients and septal pacing in 11 patients. We conclude that selected patients with ventricular dysfunction benefit from short AV delay pacing. Septal ventricular activation confers significant hemodynamic improvements over apical activation.  相似文献   

9.
Right ventricular (RV) apical pacing impairs left ventricular function by inducing dys-synchronous contraction and relaxation. Chronic RV apical pacing is associated with an increased risk of atrial fibrillation, morbidity, and even mortality. These observations have raised questions regarding the appropriate pacing mode and site, leading to the introduction of algorithms and new pacing modes to reduce the ventricular pacing burden in dual chamber devices, and a shift of the pacing site away from the RV apex. However, further investigations are required to assess the long-term results of pacing from alternative sites in the right ventricle, because long-term results so far are equivocal. The potential benefit of prophylactic biventricular, mono-chamber left ventricular, and bifocal RV pacing should be explored in selected patients with a narrow QRS complex, especially those with impaired left ventricular function. His bundle pacing is a promising and evolving technique that requires improvements in lead technology.  相似文献   

10.
[目的]对比研究右心室不同部位起搏对患者心脏结构和左心功能的影响.[方法]90例Ⅲ度或高度房室传导阻滞患者, 随机分为三组, A组行右室流入道(RVIS)间隔部起搏,B组行右室流出道(RVOT)间隔部起搏,C组行右心室心尖部(RVA)起搏. 观察三组手术中情况,监测术中血流动力学变化及手术曝光时间,比较三组术后随访的起搏器工作情况,心电图QRS波宽度,左心功能及血浆中B型钠尿肽(BNP)的差异.[结果]术中监测血流动力学,A组及B组明显优于C组.术后随访观察,A组及B组心电图QRS波宽度明显窄于C组,A组及B组具有更好的心脏功能.[结论]右心室间隔部起搏无论右室流出道起搏还是右室流入道间隔部起搏都是安全,有效的,比右室心尖部起搏更有利于双心室电激动的同步性,且长期对心脏结构及心功能影响也较少.  相似文献   

11.
Background: Chronic right ventricular apical (RVA) pacing has been associated with increased risk of heart failure and adverse outcome. The acute effects of RVA pacing on three‐dimensional (3D) ventricular function and mechanical dyssynchrony are not well known. We performed a real‐time 3D echocardiographic (RT3DE) study to assess global and regional left ventricular function during RVA pacing. Methods: Twenty‐six patients with implanted cardiac devices and normal intrinsic atrioventricular conduction were included in the study. RT3DE was performed during intrinsic sinus rhythm and during RVA pacing. Quantification of global and regional left ventricular function was performed offline by time‐volume analysis of 16 myocardial segments. Time to reach minimum regional volume was calculated for each segment as a percentage of the cardiac cycle. The systolic dyssynchrony index (SDI) was defined as the standard deviation of these time periods. Longitudinal function was assessed by time‐volume analysis of apical, midventricular, and basal segments. Results: During RVA pacing, a reversed apical‐to‐basal longitudinal contraction sequence was observed in 58% of all patients. RVA pacing was associated with increased left ventricular (LV) dyssynchrony (SDI increase from 4.4 ± 2.2% to 6.3 ± 2.4%, P = 0.001) and reduced LV ejection fraction (decrease from 53 ± 13% to 47 ± 14%, P = 0.05). Conclusion: RT3DE assessment of LV function provides evidence that pacing from the RVA results in acute alterations in LV contraction sequence and increased LV dyssynchrony. Further studies are warranted to assess the potential of RT3DE to identify patients who might be at increased risk of pacing‐induced heart failure or who might benefit from alternate‐site or multisite pacing. (PACE 2011; 76–81)  相似文献   

12.
目的:探讨右心室起搏比例和不同部位起搏对老年患者心功能的影响。方法回顾性分析92例植入体内埋藏式双腔心脏起搏器(DDD)的老年患者的临床资料,根据术后1年起搏器程控仪获取的右心室起搏比例,将右心室起搏比例≥50%患者纳入A组,右心室起搏比例<50%患者纳入B组,比较两组术前和术后1年彩色多普勒心脏超声的变化。同时,将A组分为右室心尖部(RVA)起搏者和右室间隔部(RVS)起搏者进行亚组分析。结果 A组术后1年左房内径(LAD)较术前增大,左室射血分数(LVEF)较术前和B组降低,差异均有统计学意义(t分别=2.43、4.20、6.37,P均<0.05);B组术后1年LAD、左室舒张末期内径(LVEDD)、LVEF和术前比较,差异均无统计学意义(t分别=0.73、0.78、1.16,P均>0.05)。亚组分析结果显示两亚组术前LAD、LVEDD、LVEF比较,差异均无统计学意义(t分别=0.77、0.35、1.32,P均>0.05),两组术后LVEDD、LVEF比较,差异均有统计学意义(t分别=2.86、4.62,P均<0.05),RVS组术后LAD、LVEDD、LVEF与术前比较,差异均无统计学意义(t分别=1.45、0.14、0.48,P均>0.05);而RVA组术后LAD、LVEDD均较术前明显扩大,LVEF较术前明显下降(t分别=2.20、3.13、4.31,P均<0.05)。结论老年患者中右室间隔部起搏与右室心尖部起搏相比更有利于保持患者心功能的稳定,但同时应尽量减少不必要的右心室起搏。  相似文献   

13.
The right ventricular apex has been the traditional site for lead placement in patients with atrioventricular block. Pacing at the right ventricular apex may have long-term deleterious effects on left ventricular (LV) function, promoting heart failure and increasing mortality. Pacing at the right ventricular septum has been proposed to minimize deterioration in LV function. Although experimental data suggest that septal pacing protects LV function, clinical studies have provided conflicting results. A recent large study in patients with heart block did not show a protective effect with septal pacing. Other pacing approaches are becoming increasingly relevant; however, prediction of what method should be employed in which patient is not currently possible. Other factors such as baseline LV function and associated co-morbidities impact LV function, irrespective of pacing site. Continued monitoring of cardiac function post-implant is therefore critical to ongoing care. An algorithm for managing patients with atrioventricular block is proposed.  相似文献   

14.
Permanent Ventricular Pacing Via the Great Cardiac Vein   总被引:4,自引:0,他引:4  
Two cases of left ventricular pacing via the great cardiac vein are presented. A 64-year-old female with a mechanical prosthetic tricuspid valve and slow atrial fibrillation had a failed attempt at pacing from the middle cardiac vein. In a 58-year-old male with hypertrophic obstructive cardiomyopathy and brodycardia tachycardia svndrome. transvenous permanent pacing could not be achieved via the right ventricle or middle cardiac vein. In both cases, successful pacing via the great cardiac vein was achieved but with an elevated stimulation threshold. These cases illustrate an alternate transvenous route when difficulties occur using standard ventricular pacing sites.  相似文献   

15.
Background: Compared to atrioventricular sequential pacing, ventricular demand pacing is known to have somewhat more deleterious hemodynamic effects, which probably arise from increased sympathetic tonus and inappropriate baroreceptor activation. Endothelial function is affected by various local and systemic factors including baroreceptor activity. The aim of this study was to explore whether cardiac pacing would have any effect on endothelial functions.
Methods: Twelve patients (six male, mean age: 75 ± 9 years) with previously implanted DDD or VDD cardiac pacemakers were included. All patients had stable atrial rhythms during the study. Patients were randomized to either atrial-based pacing mode (VDD or DDD) or ventricular demand pacing mode (VVI) first, and then cross-over was performed with the other pacing mode. Endothelial function was assessed by brachial artery ultrasonography. Basal diameter of the brachial artery, and both flow-mediated dilation (FMD) and endothelium-independent vasodilation with nitroglycerin were measured 1 hour after each pacing mode.
Results: Compared to atrial-based pacing mode, ventricular demand pacing was associated with a significantly worse FMD both as absolute and percentage values (0.17 ± 0.09 mm vs 0.28 ± 0.11 mm, P = 0.015 and 4.84 ± 2.37 % vs 7.00 ± 2.88 %, P = 0.028, respectively). However, there was no significant difference in nitroglycerin-mediated vasodilation values between the two pacing sessions.
Conclusions: Acute ventricular demand pacing (VVI pacing) is clearly associated with attenuation of FMD in patients with atrial-based pacing systems. The attenuation of endothelial vasodilation might have a role in hemodynamic and clinical deterioration in patients with VVI pacemakers.  相似文献   

16.
We report three patients with cardiomyopathy and pronounced stimulus to QRS latency during left ventricular (LV) pacing from an epicardial cardiac vein. Delayed LV activation during simultaneous biventricular pacing produced an electrocardiographic pattern dominated by right ventricular stimulation. Hemodynamic parameters improved immediately after advancing LV stimulation (in one patient) or pacing the LV only (in two patients) coupled with dramatic improvement of heart failure symptoms.  相似文献   

17.
BACKGROUND: Frequent and unnecessary right ventricular apical pacing increases the risk of atrial fibrillation or congestive heart failure. We evaluated a new pacing algorithm, managed ventricular pacing (MVP) which automatically changes modes between AAI/R and DDD/R in patients receiving pacemakers for symptomatic bradycardia. METHODS: Patients were randomized to the MVP mode or DDD/R mode for 1 month and then crossed over to the alternate pacing modality for an additional month. On completion of the crossover phase, the pacing mode selected was individualized and patients were followed for an additional 4 months. RESULTS: Of the 129 patients who successfully completed the crossover study, the cumulative percent ventricular pacing was significantly reduced in the MVP mode (median 1.4%) compared to the DDD/R mode (median 89.6%, 94.0% relative reduction; 95% CI 89.3-98.8%, P < 0.001). Patients with sinus node disease (SND, n = 51) when compared to patients with AV block (AVB) (n = 68) experienced a greater reduction in ventricular pacing with the MVP mode compared to the DDD/R mode (median relative reduction 99.1%; 95% CI 97.5-99.9% vs median relative reduction 60.1%; 95% CI 16.7-93.9% P < 0.001). The reduced percent ventricular pacing during MVP was sustained over longer term follow-up. CONCLUSIONS: The majority of patients with a bradycardia indication for cardiac pacing do not require ventricular pacing most of the time. The MVP mode significantly reduces unnecessary right ventricular pacing. This mode benefits even patients with intermittent AVB and is sustained over longer term follow-up.  相似文献   

18.
Background: Few studies have assessed the long‐term effects of cardiac resynchronization therapy (CRT) in patients with advanced heart failure (HF) and previously right ventricular apical pacing (RVAP). Aims: To assess the clinical and hemodynamic impact of upgrading to biventricular pacing in patients with severe HF and permanent RVAP in comparison with patients who had CRT implantation as initial therapy. Methods and Results: Thirty‐nine patients with RVAP, advanced HF (New York Heart Association [NYHA] III–IV), and severe depression of left ventricular ejection fraction (LVEF) were upgraded to biventricular pacing (group A). Mean duration of RVAP before upgrading was 41.8 ± 13.3 months. Clinical and echocardiographic results were compared to those obtained in a group of 43 patients with left bundle branch block and similar clinical characteristics undergoing “primary” CRT (group B). Mean follow‐up was 35 ± 10 months in patients of group A and 38 ± 12 months in group B. NYHA class significantly improved in groups A and B. LVEF increased from 0.23 ± 0.07 to 0.36 ± 0.09 (P < 0.001) and from 0.26 ± 0.02 to 0.34 ± 0.10 (P < 0.001), respectively. Hospitalizations were reduced by 81% and 77% (P < 0.001). Similar improvements in echocardiographic signs of ventricular desynchronization were also observed. Conclusion: Patients upgraded to CRT exhibit long‐term clinical and hemodynamic benefits that are similar to those observed in patients treated with CRT as initial strategy. (PACE 2010; 841–849)  相似文献   

19.
In patients needing a pacemaker (PM) for bradycardia indications, the amount of right ventricular (RV) apical pacing has been correlated with atrial fibrillation (AFib) and heart failure (HF) in both DDD and VVI mode. RV pacing was linked with left ventricular (LV) dyssynchrony in almost 50% of patients with PM implantation and atrioventricular (AV) node ablation for AFib. In patients with normal systolic function needing a PM, apical RV pacing resulted in LV ejection fraction (LVEF) reduction. These negative effects were prevented by cardiac resynchronization therapy (CRT). Algorithms favoring physiological AV conduction are possible useful tools able to maintain both atrial and ventricular support and limit RV pacing. However, when chronic RV pacing cannot be avoided, it appears necessary to reconsider the cut-off value of basic LVEF for CRT. In HF patients, RV pacing can induce greater LV dyssynchrony, enhanced by underlying conduction diseases. In this context, a more deleterious effect of RV pacing in implantable cardioverter-defibrillator (ICD) patients with low LVEF can be expected. In some major ICD trials, DDD mode was correlated with increased mortality/HF. This negative impact was attributed to unnecessary RV pacing >40-50%, virtually absent in VVI-40 mode. However, some data suggest that avoiding RV pacing may also not be the best option for patients requiring an ICD. In patients with impaired LV function, AV synchrony should therefore be ensured. The best pacing mode in ICD patients with HF should be defined on an individual basis.  相似文献   

20.
The aim of this study was to evaluate the importance of a normal ventricular activation pattern for cardiac performance. In nine mongrel clogs, atrial pacing was compared to AV synchronous pacing at three different A V delays (150, 100, and 60 nis). In six dogs, proximal septal AV synchronous pacing was compared to apical A V synchronous pacing at three different A V delays. AV synchronous pacing was performed after RF induced complete heart block. Hemodynarnics were evaluated by assessment of positive and negative dP/dt, cardiac output, and left ventricular and pulmonary pressures. Atrial pacing was superior to AV synchronous pacing with respect to positive and negative dP/dt and cardiac output. This difference was present at all AV delays. Proximal septal pacing was associated with a higher positive and negative dP/dl compared to apical pacing at all AV delays. Left ventricular activation time was significantly shorter during proximal septal pacing than during apical pacing (88 ± 4 vs 115 ± 4 ms, P < 0.001). We conclude that atrial and proximal septal pacing improves cardiac function and shortens the ventricular activation time compared to apical AV synchronous pacing independent of the AV interval.  相似文献   