首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Combining acoustic and electrical hearing   总被引:5,自引:0,他引:5  
Gantz BJ  Turner CW 《The Laryngoscope》2003,113(10):1726-1730
OBJECTIVES/HYPOTHESIS: The concept of combining electrical stimulation for high-frequency sound with acoustic hearing for low-frequency information was tested. In addition, whether residual hearing can be preserved when an electrode is placed into the inner ear up to 10 mm and whether place of electrical stimulation influences speech perception were tested. STUDY DESIGN: A single-subject clinical trial design was employed. METHODS: Six postlingual adults with severe high-frequency hearing impairment were recruited to participate in the study. A new six-channel cochlear implant was designed for the clinical trial. The intracochlear electrodes were either 6 or 10 mm in length based on a Nucleus CI-24 multichannel implant. Monosyllabic word understanding and consonant identification testing in a recorded sound-only condition were used to assess changes in speech perception. Follow-up was greater than 12 months. RESULTS: Acoustic hearing was preserved in all six subjects (n = 3, 6-mm electrodes; n = 3, 10-mm electrodes). Preoperative monosyllabic word and sentence scores were unchanged in all subjects following implantation. A 30% to 40% improvement in consonant recognition occurred with the 10-mm electrode. The subjects with 10-mm electrodes were able to understand 83% to 90% of the monosyllabic words using the implant plus binaural hearing aids. Scores were more than doubled when compared with preoperative scores with hearing aids only. CONCLUSION: The human ear has the capability to integrate both acoustic and high-frequency electrically processed speech information. Placement of a short, 10-mm electrode does not appear to damage residual low-frequency inner ear hair cell function, interfere with the micro mechanics of normal cochlear vibration, or decrease residual speech perception. The improvement in speech recognition was due primarily to the increased perception of higher-frequency consonantal speech cues, and this improvement took several months to become apparent. Such a device can provide a substantial benefit in speech understanding to individuals with severe high-frequency hearing loss, while still maintaining the benefits of the residual lower-frequency acoustic hearing. The position of the electrode and the place of frequency information within the cochlea were shown to be important factors in the success of such a device.  相似文献   

2.
Conclusion: Differences were found between patients with stable hearing and those with progressive hearing loss in the lower frequencies with respect to the rate of progression in the contralateral ear. It is suggested that the electric acoustic stimulation (EAS) can provide improvement in hearing ability over the long-term if residual hearing might be lost to some extent.

Objective: To evaluate the long-term threshold changes in the low frequency hearing of the implanted ear as compared with the non-implanted ear, and the hearing abilities with EAS along with the extent of residual hearing.

Methods: Seventeen individuals were enrolled and received the EAS implant with a 24-mm FLEXeas electrode array. Hearing thresholds and speech perception were measured pre- and post-operatively for 1–5 years. Post-operative hearing preservation (HP) rates were calculated using the preservation numerical scale.

Results: The average linear regression coefficient for the decline in hearing preservation score was ?6.9 for the implanted ear and the patients were subsequently categorized into two groups: those with better than average, stable hearing; and those with worse than average, progressive hearing loss. EAS showed better results than electric stimulation alone, in spite of an absence of speech perception with acoustic stimulation.  相似文献   

3.
Objective: To examine post-implantation benefit and time taken to acclimate to the cochlear implant for adult candidates with more hearing in the contralateral non-implanted ear than has been previously considered within local candidacy guidelines. Design: Prospective, within-subject experimental design. Study sample: Forty postlingual hearing-impaired adult subjects with a contralateral ear word score in quiet ranging from 27% to 100% (median 67%). Results: Post-implantation improvement of 2.4?dB and 4.0?dB was observed on a sentence in coincident babble test at presentation levels of 65 and 55?dB SPL respectively, and a 2.1?dB benefit in spatial release from masking (SRM) advantage observed when the noise location favoured the implanted side. Significant post-operative group mean change of between 2.1 and 3.0 was observed on the sub-scales of the speech, spatial, and qualities (SSQ) questionnaire. Degree of post-implantation speech reception threshold (SRT) benefit on the coincident babble test and on perception of soft speech and sounds in the environment was greater for subjects with less contralateral hearing. The degree of contralateral acoustic hearing did not affect time taken to acclimate to the device. Conclusions: The findings from this study support cochlear implantation for candidates with substantial acoustic hearing in the contralateral ear, and provide guidance regarding post-implantation expectations.  相似文献   

4.
Objective: A psychoacoustic procedure designed for the precise assessment of perceptional threshold (T-level) in cochlear implant (CI) users is presented. The impact of this procedure on speech perception was investigated. Design: Individual T-level measurements were obtained with the proposed procedure and three different speech processor fitting conditions were applied: (1) fitting familiar to the subject, T-levels unchanged, (2) T-level set to thresholds determined with the new procedure, (3) T-level set to thresholds determined with the new procedure, but T-level is decreased by 10 clinical units (CU). The impact of the different fitting conditions was measured by means of categorical loudness scaling (CLS) and speech perception tests in quiet and noise. Study sample: A prospective study at a tertiary referral university hospital. 18 experienced postlingually deafened cochlear implanted adult subjects. Results: Average sound-field thresholds obtained by CLS were lowest in condition using the new procedure yielding a larger dynamic range with significantly higher speech scores in quiet compared to those with a subject’s commonly used programme, and significantly improved in noise even after reducing T-levels by 10 CU. Conclusion: The precise determination of T-levels by means of the proposed procedure improved performance in several speech recognition tasks. Compared to the default behavioural setting, T-level increased on median by 9 CU. Average speech reception threshold in noise for soft speech levels (50?dB sound pressure level) decreased by 1?dB.  相似文献   

5.
OBJECTIVE: The objective of this study was to assess the intracochlear position and the extent of trauma to cochlear structures using a new prototype electrode carrier (Flex EAS). Special emphasis was placed on the practicality for combined electric and acoustic stimulation of the auditory system. STUDY DESIGN: Human temporal bones were evaluated histologically after insertion of the electrodes, and insertion forces were measured in an acrylic model of the scala tympani. METHODS: 1) Insertion forces with the regular C40+ array and the new electrode prototype were measured in an acrylic model of the scala tympani. 2) Ten human temporal bones were implanted using the same surgical procedure as in vivo. All bones underwent fixation methylmethacrylate embedding to allow cutting of the undecalcified bone with the electrode in situ. In addition, radiography of the implanted devices was performed and correlated to histologic results. Electrode positions and trauma to cochlear structures were then evaluated histologically. RESULTS: All insertions of the new electrode array were performed in the scala tympani of the cochlea. All insertions were atraumatic and covered one cochlear turn. The only effect on cochlear structures that could be observed was a slight lifting of the basilar membrane in the middle turn limited to the tip of the electrode. In three bones, basal trauma, which resulted from the cochleostomy itself, could be observed as well. All neural structures remained intact. CONCLUSIONS: The new electrode prototype provides very good mechanical properties for safe and atraumatic implantation. All criteria for the use in hearing-preservation cochlear implantation for electric and acoustic stimulation were fulfilled. Surgical measures to prevent basal trauma appear to be very important.  相似文献   

6.
We assessed sound localisation abilities of late-implanted adults fitted with a single cochlear implant (CI) and examined whether these abilities are affected by the duration of implant use. Ten prelingually and four postlingually deafened adults who received a unilateral CI were tested in a sound-source identification task. Above chance performance was observed in those prelingual CI recipients who had worn their implant for longer time (9 years on average), revealing some monaural sound localisation abilities in this population but only after extensive CI use. On the contrary, the four postlingual recipients performed equal or better with respect to the best prelingual participants despite shorter experience with the monaural implant (11 months on average). Our findings reveal that some sound localisation ability can emerge in prelingually deafened adults fitted with a single implant, at least in a controlled laboratory setting. This ability, however, appears to emerge only after several years of CI use. Furthermore, the results of four postlingually deafened adults suggest that early experience with auditory cues may result in more rapid acquisition of spatial hearing with a single CI.  相似文献   

7.
Abstract

Objectives

Modern cochlear implant (CI) encoding strategies represent the temporal envelope of sounds well but provide limited spectral information. This deficit in spectral information has been implicated as a contributing factor to difficulty with speech perception in noisy conditions, discriminating between talkers and melody recognition. One way to supplement spectral information for CI users is by fitting a hearing aid (HA) to the non-implanted ear.

Methods

In this study 14 postlingually deaf adults (half with a unilateral CI and the other half with a CI and an HA (CI + HA)) were tested on measures of music perception and familiar melody recognition.

Results

CI + HA listeners performed significantly better than CI-only listeners on all pitch-based music perception tasks. The CI + HA group did not perform significantly better than the CI-only group in the two tasks that relied on duration cues. Recognition of familiar melodies was significantly enhanced for the group wearing an HA in addition to their CI. This advantage in melody recognition was increased when melodic sequences were presented with the addition of harmony.

Conclusion

These results show that, for CI recipients with aidable hearing in the non-implanted ear, using a HA in addition to their implant improves perception of musical pitch and recognition of real-world melodies.  相似文献   

8.
9.
Preservation of residual hearing should be a desirable outcome of implant surgery. Prevention of neural degeneration due to loss of residual hair cells, together with the continuous progress in cochlear implant technology should be able to preserve cochlear integrity as well as possible. The degree of hearing preservation may vary depending on surgical approach, maximum insertion depth and other factors not uniformly considered to date. The aim of this retrospective case controlled study is to evaluate residual hearing after cochlear implant surgery. In particular, we analyzed data obtained with use of two different kinds of electrode arrays, with and without rigid introductor (stylet). We report the results on 37 patients with measurable preoperative hearing thresholds, mean age of 28 years (5–70 years), having the following implants: seven Advanced Bionics®, four Med-El®, 24 Cochlear®, two MXM®; 19 of them were performed using the stylet and the other 18 without it. A minimally invasive surgical approach was performed with a short retroauricular incision and a 1.2 mm cochleostomy. A complete electrode array insertion was obtained in all patients. Responses to pure-tone stimuli were measured for each ear in pre-implantation conditions and 3–12 months after surgery. After implantation 14 patients (38%) showed no hearing threshold variation, 29 (78%) maintained an appreciable hearing threshold level in the implanted ear, 8 (22%) had a total loss of residual hearing. Median increases of threshold levels were, in all 37 studied patients, 5, 10, 10 and 5 dB HL, respectively, for 125, 250, 500 and 1 kHz. For the 18 patients having implants without the stylet median increases of threshold levels were 0, 10, 5 and 7 dB HL; in the stylet group, they were 10, 5, 5 and 10 dB HL. On a comparison between the stylet and the non-stylet group, no significant differences in mean hearing threshold worsening were found. Data seem to suggest that cochlear function is less sensitive to mechanical trauma during implant surgery than was thought. Besides, electrode array stiffness seems not to influence preservation of cochlear residual functional integrity. Finally, the authors hypothesize a direct spiral ganglion activation under strong mechanical stimulation.  相似文献   

10.
OBJECTIVES/HYPOTHESIS: This study documents the importance of preserving residual low-frequency acoustic hearing as those with more residual hearing are selected for cochlear implantation. Surgical strategies used for hearing preservation with a short hybrid cochlear implant are outlined. The benefits of preserved residual low-frequency hearing, improved word understanding in noise, and music appreciation are described. STUDY DESIGN: Multicenter, prospective, single-subject design. METHODS: Records were reviewed of 21 individuals participating in an Food and Drug Administration (FDA) feasibility clinical trial who have received an Iowa/Nucleus 10 mm electrode. A second group of subjects receiving implants at the University of Iowa that have used the 10 mm device between 2 years and 6 months were also reviewed. Outcome measures included standardized tests of monosyllabic word understanding, spondees in noise, and common melody recognition. RESULTS: Low-frequency hearing was maintained in all individuals immediately postoperative. One subject lost hearing at 2.5 months postoperative after a viral infection. The group has averaged a loss of -9 dB low-frequency acoustic hearing between 125 and 1,000 Hz. Monosyllabic word understanding scores at 6 months for a group being followed for an FDA clinical trial using the implant plus hearing aids was 69% correct. For the long-term group receiving implants at Iowa, monosyllabic word understanding in those who have used the device between 6 months and 2 years is 79%. Other important findings include improved recognition of speech in noise (9 dB improvement) as compared with standard cochlear implant recipients who were matched for speech recognition in quiet and near normal recognition of common melodies. CONCLUSION: The surgical strategies outlined have been successful in preservation of low-frequency hearing in 96% of individuals. Combined electrical and acoustical speech processing has enabled this group of volunteers to gain improved word understanding as compared with their preoperative hearing with bilateral hearing aids and a group of individuals receiving a standard cochlear implant with similar experience with their device. The improvement of speech in noise and melody recognition is attributed to the ability to distinguish fine pitch differences as the result of preserved residual low-frequency acoustic hearing. Preservation of low-frequency acoustic hearing is important for improving speech in noise and music appreciation for the hearing impaired, both of which are important in real-life situations.  相似文献   

11.
Conclusion: Seven-day administration of systemic steroids was more effective in preserving hearing for 12 weeks after cochlear implantation (CI) than a 3-day delivery.

Objectives: To determine the effectiveness of extended delivery of systemic steroids to preserve hearing in guinea pigs after CI.

Methods: Dexamethasone (4?mg/ml) was delivered parenterally via a mini-osmotic pump for either 3 or 7 days. A dummy CI electrode was inserted via cochleostomy approach in 8-week-old guinea pigs. Auditory thresholds were assessed from tone burst auditory brainstem responses (2, 8, 16, 24, and 32?kHz) at 1?day prior to CI, and 1, 4, and 12 weeks after implantation. Histologic evaluation of the cochleae was carried out.

Results: No differences were observed in hearing thresholds among groups before CI. Significant hearing preservation was achieved at 8, 16, 24, and 32?kHz only in the 7-day infusion group compared with the control group at 1 week after CI. The same trend was maintained at 4 weeks (16, 24?kHz) and 12 weeks (16, 24, and 32?kHz). Histologic review of the 7-day infusion group revealed less fibrosis and ossification in the scala tympani and the preservation of more spiral ganglion cells, compared with the control group.  相似文献   

12.
13.
Objectives: The performance outcome with Freedom? Hybrid? versus the CP900 series sound processor with Hybrid Hearing was investigated. In addition, a preliminary evaluation was conducted to consider the feasibility of upgrading experienced electric-only cochlear implant (CI) users who had substantial residual hearing to Hybrid Hearing.

Methods: This study was a single-centre prospective, non-inferiority design with repeated measures conducted at Hannover Medical School (MHH). The randomized AABB cross-over design to compensate for learning effects included two test groups. Group 1 compared two systems for Hybrid Hearing (Freedom Hybrid sound processor versus CP900 series sound processor) and Group 2 compared CP900 series sound processor (electric-only) versus the CP900 with Hybrid Hearing in experienced CI users who had confirmed residual low-frequency hearing. Groups 1 and 2 were composed of different participants.

Results: Group 1 (n?=?24) performance on speech perception tests was equivalent or superior with the CP900 series sound processor showing a statistically significant mean improvement of 1.87?dB in background noise (P?P?=?0.064) for participants tested with the CP900. The patient-reported outcome questionnaire confirmed the beneficial performance with the CP900 series sound processor with Hybrid Hearing. The feasibility portion of the study (Group 2, n?=?14) showed an average benefit of 0.54?dB in background noise when using the CP900 with Hybrid Hearing function versus electric-only stimulation.

Conclusions: The outcome presents sufficient evidence to show the effectiveness of the CP900 series sound processor with Hybrid Hearing over the Freedom Hybrid for participants with substantial residual hearing. Positive outcomes were observed for improved speech understanding and subjective hearing performance. Further, a trend was demonstrated in the data towards better performance with CP900 with Hybrid Hearing versus electric-only stimulation. Hybrid Hearing users showed a clinically relevant and statistically a significant benefit from the current CP900 series sound processor generation supporting its recommendation, on a case-by-case basis, to current electric-only users. More research is needed to confirm these findings.  相似文献   

14.
目的:探讨人工耳蜗与助听器对聋儿嗓音音质的影响机制。方法:随机选择昕障儿童组成健听组、助听器组、人工耳蜗组以及裸耳听障组,其中健听组与裸耳听障组作为对照控制组。采用“嗓音疾病评估仪”(TigerDRS)进行嗓音音质评估,要求儿童发/越/音,持续3s。测试的声学参数为:F0、SDF0、Jitter、Shimmer、NNE、HNR、SNR。结果:人工耳蜗组的嗓音F0显著小于其他各组(均P〈0.05),助听器组、健听组、裸耳听障组之间的嗓音F0无显著性差异(P〉0.05);人工耳蜗组与助听器组的SDF0显著大于健听组和裸耳听障组(P〈0.05),助听器及人工耳蜗对听障女性患儿嗓音SDFo的影响大于昕障男性患儿,其交互作用达显著临界水平(P〉0.05);各组之间的嗓音音质参数(Jitter、Shimmer、NNE、HNR、SNR)差异无统计学意义(P〉0.05)。结论:人工耳蜗与助听器主要影响的是嗓音F0及SDF0,而对其他音质参数影响不大。  相似文献   

15.
Abstract

Hypothesis

Revision surgery using a newer-generation conventional length cochlear implant electrode will provide improved speech perception in patients that initially underwent hybrid electrode implantation and experienced post-operative loss of residual hearing and performance deterioration.

Clinical presentation

We present four patients who experienced delayed post-operative hearing loss following implantation with the Nucleus Hybrid S8 device and underwent reimplantation with the Nucleus Freedom or Nucleus 5 device using the Contour Advance array. Pure-tone thresholds and speech perception data were retrospectively reviewed.

Intervention

Four subjects underwent reimplantation with the Nucleus Freedom or Nucleus 5 device after experiencing deteriorating performance related to delayed acoustic hearing loss. Comparison of pre-revision performance to the most recent post-revision performance demonstrated improved speech perception performance in all subjects following reimplantation.

Conclusions

A small percent of patients will experience a significant loss of residual low-frequency hearing following hybrid implantation thereby becoming completely reliant on a shorter electrode for electrical stimulation. In the current series, reimplantation with a conventional length electrode provided improved speech perception performance in such patients. Revision surgery with a conventional length electrode should be considered in ‘short electrode’ recipients who experience performance deterioration following loss of residual hearing.  相似文献   

16.
Objective: The aims of this study were: to investigate the referral rates of postlingually deafened adult cochlear implant (CI) candidates from a hearing aid (HA) clinic for a CI candidacy assessment and to gain insight about factors influencing the referral pathways to CI assessments. Design: Two methodologies were used: a retrospective cohort study reviewing clinical files and a questionnaire to clinicians. Study sample: The files of 1249 adult clients from the HA clinic who had average puretone hearing thresholds greater or equal to 65?dB?HL in the better hearing ear and unaided phoneme recognition scores of less than 50% in both ears were reviewed. All of the clinicians completed the online questionnaire. Results: Eighteen adults met the CI candidacy criteria, of whom 16 (89%) had a CI discussion with their audiologist, with 11 (61%) being referred for a CI evaluation. Of these 11, four proceeded to implantation. Questionnaire responses revealed the need for better information on candidacy and referral guidelines for HA audiologists, in addition to enhanced communication between HA and CI clinics. Conclusions: Overall the results indicate that the referral pathway to obtain a CI assessment is a barrier contributing to the low CI penetration rate in adults.  相似文献   

17.
Abstract

Objectives

The present study characterizes the relationship between bimodal benefit and hearing aid (HA) performance, cochlear implant (CI) performance, and the difference in the performances of the two devices.

Methods

Fourteen adult bimodal listeners participated in the study. Consonant, vowel, and sentence recognition were measured in quiet and noise (at a +5 and +10 dB signal-to-noise ratio (SNR)) with an HA alone, a CI alone, and with the combined use of an HA and CI in each listener. Speech and noise were presented directly in front of the listener.

Results

The correlation analyses showed that bimodal benefit was significantly associated with the difference in performances of a CI and an HA in all testing materials, with HA-alone performance in vowel recognition, and with CI-alone performance in sentence recognition. However, regression analyses showed that the independent contribution of the difference in performance across ears to bimodal benefit was significant, irrespective of the testing material or the SNR: the smaller the difference, the greater the benefit. Further, the independent contributions of HA-only performance and CI-alone performance were not significant factors in predicting the existence of bimodal benefit across testing materials and SNRs when the effect of the difference between CI and HA performance was removed from the model.

Conclusion

The results suggest that bimodal benefit is limited by how effectively the modalities integrate, rather than HA-only or CI-alone performance, and that this integration is facilitated when the performances of the modalities are similar.  相似文献   

18.
Cochlear implant in patients with residual hearing   总被引:1,自引:0,他引:1  
Objective: The postoperative speech perception abilities of severely hearing-impaired patients with multi-channel cochlear implant were compared with preoperative speech perception performance with conventional hearing aids. Methods: Cochlear implantation was performed in six severely to profoundly hearing-impaired patients. They had unaided pure-tone thresholds of 70–100-dB HL and aided thresholds of 35–90-dB HL in the better ear, but were not able to perceive speech sounds well with hearing aids. Results: Postoperatively, all the patients had significantly improved speech perception performance, exceeded the average skills of profoundly deaf cochlear implant users, and were able to communicate without writing. Conclusion: These results imply that cochlear implant may be indicated for severely to profoundly deaf subjects, if they receive little or no benefit from conventional hearing aids.  相似文献   

19.
Introduction: A retrospective evaluation of pre- and post-operative audiometric data at a single large UK cochlear implant centre over 25 years was undertaken.

Methods: Analysis of pre-operative hearing levels showed that there was a modest but significant reduction in average pre-operative hearing thresholds among patients referred between 1990 and 2015, particularly in the low frequencies.

Outcomes: The proportion of those referred who would meet widely-accepted candidacy criteria for electro-acoustic stimulation (EAS) grew significantly over time but in the period 2011-2015 just 9% of those referred had sufficient residual hearing for EAS. On average, implant recipients lost 20 dB hearing at frequencies ≤1000 Hz as a result of the surgery.

Conclusions: The findings suggest that hearing preservation is now widely achievable, and that both candidacy criteria and referrer education should take into account potential EAS benefit.  相似文献   

20.
Objective: This study investigates the effect of spectral loudness summation (SLS) in the electrical domain as perceived by cochlear implant (CI) users. Analogous to SLS in the acoustical domain, SLS was defined as the effect of electrode separation at a fixed overall stimulation rate. Design: Categorical loudness scaling (CLS) was conducted at three overall stimulation rates using single-electrode stimuli and multi-electrode stimuli presented interleaved on two or four electrodes. The specific loudness of the pulses in the multi-electrode stimuli were equalized based on single-electrode measurements at the same overall stimulation rate. At a fixed overall stimulation rate and a fixed loudness perception, SLS was calculated as the difference in mean current between single-electrode and multi-electrode stimuli. Study sample: Ten postlingually deafened adult CI users. Results: The amount of SLS varied between subjects and between the number and location of the stimulated electrodes in the multi-electrode configuration. SLS was significantly higher than 0 for a subset of the subjects. Conclusions: For a subpopulation of CI users, loudness models should account for nonlinear interactions between electrodes (in the perceptual domain). Similarly, SLS should be accounted for when using CLS outcomes for fitting purposes, at least in a subpopulation of CI users.  相似文献   