1.
BACKGROUND: Entropy, a newly available electroencephalographic monitor, demonstrates two parameters, response entropy (RE) and state entropy (SE). The aim of this study is to compare RE and SE with bispectral index (BIS) during anesthetic induction with propofol. METHODS: Fifteen patients received target controlled infusion of propofol starting at 3 microg x ml(-1). We measured RE, SE and BIS and recorded effect-site concentrations of propofol at three sedation levels: VR1; conscious state before infusion of propofol, VR2; no response to verbal command, and VR3; no response to verbal command and shaking. Spearman rank correlations and prediction probability for sedation level were analyzed. RESULTS: Effect-site concentrations of propofol at VR1, VR2, and VR3 were 0, 1.8 +/- 0.7, and 2.4 +/- 0.7, respectively. All three parameters showed significant correlations with sedation levels. Prediction probability values of SE, RE, and BIS were 0.905, 0.894, and 0.890, respectively. CONCLUSIONS: Response entropy and SE can provide similar information as BIS about the sedation level with propofol.  相似文献   

2.
BACKGROUND: Time-frequency balanced spectral entropy of electroencephalogram (EEG) and frontal electromyogram (FEMG) is a novel measure of hypnosis during anesthesia. Two Entropy parameters are described: Response entropy (RE) is calculated from EEG and FEMG; and State Entropy (SE) is calculated mainly from EEG. This study was performed to validate their performance during transition from consciousness to unconsciousness under different anesthetic agents. METHODS: Response entropy, SE [S/5 Entropy Module, M-ENTROPY (later in text: Entropy), Datex-Ohmeda Division, Instrumentarium Corp., Helsinki, Finland] and BIS (BIS XP, A-2000, Aspect Medical Systems, Newton, MA) data were collected from 70 patients; 30 anesthetized with propofol 2 mg kg-1, 20 with sevoflurane inhalation, and 20 with thiopental 5 mg kg-1. Loss and regaining of consciousness (LOC, ROC) was tested every 10 s, and sensitivity, specificity, and prediction probability (Pk) were calculated. Behavior of the indices was studied. RESULTS: Sensitivity, specificity, and Pk values for consciousness were high and similar for all indices. During regaining of consciousness after propofol bolus, RE, SE, and BIS values recovered by 81 +/- 22%, 75 +/- 26%, and 59 +/- 18% (mean +/- SD), respectively, from the minimum relative to their baseline. After thiopental bolus, RE, SE, and BIS values recovered by 86+/-21%, 88 +/- 13%, and 63 +/- 14%, respectively. The relative rise was higher in RE and SE compared with BIS (P < 0.01). During deep levels of hypnosis, RE and SE decreased monotonously as a function of burst suppression ratio, while BIS showed biphasic behavior. On average, RE indicated emergence from anesthesia 11 s earlier than SE, and 12.4 s earlier than BIS. CONCLUSIONS: All indices, RE, SE, and BIS, distinguished excellently between conscious and unconscious states during propofol, sevoflurane, and thiopental anesthesia. During burst suppression, Entropy parameters RE and SE, but not BIS, behave monotonously. During regaining of consciousness after a thiopental or propofol bolus, RE and SE values recovered significantly closer to their baseline values than did BIS. Response entropy indicates emergence from anesthesia earlier than SE or BIS.  相似文献   

3.
BACKGROUND: Recently, entropy algorithms have been proposed as electroencephalographic measures of anesthetic drug effects. Datex-Ohmeda (Helsinki, Finland) introduced the Entropy Module, a new electroencephalographic monitor designed for measuring depth of anesthesia. The monitor calculates a state entropy (SE) computed over the frequency range of 0.8-32 Hz and a response entropy (RE) computed over the frequency range of 0.8-47 Hz. The authors investigated the dose-response relation of SE and RE during sevoflurane anesthesia in comparison with the Bispectral Index (BIS). METHODS: Sixteen patients were studied without surgical stimulus. Anesthesia was induced by sevoflurane inhalation with a tight-fitting facemask. Sevoflurane concentrations were increased and subsequently decreased and increased two to four times until the measurement was stopped and patients were intubated for surgery. The performances of SE, RE, and BIS to predict the estimated sevoflurane effect site concentration, obtained by simultaneous pharmacokinetic and pharmacodynamic modeling, were compared by calculating the correlation coefficients and the prediction probability. RESULTS: State entropy, RE, and BIS values decreased continuously over the observed concentration range of sevoflurane. Correlation coefficients were slightly but not significantly better for entropy parameters (0.87 +/- 0.09 and 0.86 +/- 0.10 for SE and RE, respectively) than for BIS (0.85 +/- 0.12). Calculating the prediction probability confirmed these results with a prediction probability of 0.84 +/- 0.05 and 0.82 +/- 0.06 for SE and RE, respectively, and 0.80 +/- 0.06 for BIS. CONCLUSION: State entropy and RE seem to be useful electroencephalographic measures of sevoflurane drug effect.  相似文献   

4.
Background: Recently, entropy algorithms have been proposed as electroencephalographic measures of anesthetic drug effects. Datex-Ohmeda (Helsinki, Finland) introduced the Entropy Module, a new electroencephalographic monitor designed for measuring depth of anesthesia. The monitor calculates a state entropy (SE) computed over the frequency range of 0.8-32 Hz and a response entropy (RE) computed over the frequency range of 0.8-47 Hz. The authors investigated the dose-response relation of SE and RE during sevoflurane anesthesia in comparison with the Bispectral Index (BIS).

Methods: Sixteen patients were studied without surgical stimulus. Anesthesia was induced by sevoflurane inhalation with a tight-fitting facemask. Sevoflurane concentrations were increased and subsequently decreased and increased two to four times until the measurement was stopped and patients were intubated for surgery. The performances of SE, RE, and BIS to predict the estimated sevoflurane effect site concentration, obtained by simultaneous pharmacokinetic and pharmacodynamic modeling, were compared by calculating the correlation coefficients and the prediction probability.

Results: State entropy, RE, and BIS values decreased continuously over the observed concentration range of sevoflurane. Correlation coefficients were slightly but not significantly better for entropy parameters (0.87 +/- 0.09 and 0.86 +/- 0.10 for SE and RE, respectively) than for BIS (0.85 +/- 0.12). Calculating the prediction probability confirmed these results with a prediction probability of 0.84 +/- 0.05 and 0.82 +/- 0.06 for SE and RE, respectively, and 0.80 +/- 0.06 for BIS.  相似文献   


5.
Bispectral index and spectral entropy in neuroanesthesia   总被引:1,自引:0,他引:1  
Spectral Entropy (SpEn) is an alternative tool to the bispectral index (BIS) for monitoring depth of hypnosis. SpEn measures response entropy (RE) and state entropy (SE). This open-label prospective study was designed to evaluate SpEn and BIS in 20 patients undergoing elective supratentorial neurosurgery with craniotomy and resection of brain tumors. SpEn and BIS were obtained continuously by Datex Ohmeda M-entropy module S/5 (Helsinki, Finland) and Aspect Medical System BIS (Newton), respectively. Total intravenous anesthesia was performed in all patients by Fresenius Vial infusion system (Brezins, France) to maintain a plasma concentration of propofol of 2.5 to 5 microg mL(-1) and sufentanil of 0.2 to 0.4 etag mL(-1). SpEn, BIS, the estimated propofol effect-site concentrations (Ce), the mean arterial pressure (MAP), and the heart rate (HR) were recorded during 12 specific events: induction of anesthesia, patient stop counting, loss of blinking reflex, intubation, mayfield pinning, craniotomy, termination of propofol infusion, recovery of blinking reflex, coughing, limb movement, order execution, and extubation. Stated that prediction probability or P(K) represents an indicator probability to predict correctly the rank order of an arbitrary pair of distinct observed indices of depth of hypnosis (ie, clinical settings and SpEn indices, or BIS, Ce, MAP, HR), PK of BIS, SE, RE, and Ce provided a better depth of hypnosis than MAP and HR; RE being the best for rapidity, SE for sensitivity, and BIS for specificity. There is good correlation between the 3 hypnosis indices and Ce. This study demonstrates that SpEn provides a reproducible hypnosis index for patients undergoing supratentorial neurosurgical procedures.  相似文献   

6.
BACKGROUND: Different analytical concepts were introduced to quantify the changes of the electroencephalogram. The Datex-Ohmeda S/5 Entropy Module (Datex-Ohmeda Division, Instrumentarium Corp., Helsinki, Finland) was the first commercial monitor based on the entropy generating two indices, the state entropy (SE) and the response entropy (RE). The aim of the current study was to compare the accuracy of SE and RE with the Bispectral Index(R) monitor (BIS(R); Aspect Medical Systems, Newton, MA) during propofol-remifentanil anesthesia. METHODS: The authors investigated 20 female patients during minor gynecologic surgery. SE, RE, BIS, mean arterial blood pressure, heart rate, and sedation level were recorded every 20 s during stepwise increase (target-controlled infusion, 0.5 microg/ml) of propofol until the patients lost response. Five minutes after loss of response, remifentanil infusion (0.4 microg . kg(-1) . min(-1)) was started. Spearman correlation coefficient and prediction probability were calculated for sedation levels with SE, RE, BIS, mean arterial blood pressure, and heart rate. The ability of the investigated parameters to distinguish between the anesthesia steps awake versus loss of response, awake versus anesthesia, anesthesia versus first reaction, and anesthesia versus extubation was analyzed with the prediction probability. RESULTS: SE correlates best with sedation levels, but no significant differences of the prediction probability values among SE, RE, and BIS were found. The prediction probability for all investigated steps of anesthesia did not show significant differences among SE, RE, and BIS. SE, RE, and BIS were superior to mean arterial blood pressure and heart rate. CONCLUSION: SE, RE, and BIS revealed similar information about the level of sedation and allowed the authors to distinguish between different steps of anesthesia. Both monitors provided useful additional information for the anesthesiologist.  相似文献   

7.
Background: The authors compared the behavior of two calculations of electroencephalographic spectral entropy, state entropy (SE) and response entropy (RE), with the A-Line(R) ARX Index (AAI) and the Bispectral Index (BIS) and as measures of anesthetic drug effect. They compared the measures for baseline variability, burst suppression, and prediction probability. They also developed pharmacodynamic models relating SE, RE, AAI, and BIS to the calculated propofol effect-site concentration (Ceprop).

Methods: With institutional review board approval, the authors studied 10 patients. All patients received 50 mg/min propofol until either burst suppression greater than 80% or mean arterial pressure less than 50 mmHg was observed. SE, RE, AAI, and BIS were continuously recorded. Ceprop was calculated from the propofol infusion profile. Baseline variability, prediction of burst suppression, prediction probability, and Spearman rank correlation were calculated for SE, RE, AAI, and BIS. The relations between Ceprop and the electroencephalographic measures of drug effect were estimated using nonlinear mixed effect modeling.

Results: Baseline variability was lowest when using SE and RE. Burst suppression was most accurately detected by spectral entropy. Prediction probability and individualized Spearman rank correlation were highest for BIS and lowest for SE. Nonlinear mixed effect modeling generated reasonable models relating all four measures to Ceprop.  相似文献   


8.
Background: Different analytical concepts were introduced to quantify the changes of the electroencephalogram. The Datex-Ohmeda S/5 Entropy Module (Datex-Ohmeda Division, Instrumentarium Corp., Helsinki, Finland) was the first commercial monitor based on the entropy generating two indices, the state entropy (SE) and the response entropy (RE). The aim of the current study was to compare the accuracy of SE and RE with the Bispectral Index(R) monitor (BIS(R); Aspect Medical Systems, Newton, MA) during propofol-remifentanil anesthesia.

Methods: The authors investigated 20 female patients during minor gynecologic surgery. SE, RE, BIS, mean arterial blood pressure, heart rate, and sedation level were recorded every 20 s during stepwise increase (target-controlled infusion, 0.5 [mu]g/ml) of propofol until the patients lost response. Five minutes after loss of response, remifentanil infusion (0.4 [mu]g [middle dot] kg-1 [middle dot] min-1) was started. Spearman correlation coefficient and prediction probability were calculated for sedation levels with SE, RE, BIS, mean arterial blood pressure, and heart rate. The ability of the investigated parameters to distinguish between the anesthesia steps awake versus loss of response, awake versus anesthesia, anesthesia versus first reaction, and anesthesia versus extubation was analyzed with the prediction probability.

Results: SE correlates best with sedation levels, but no significant differences of the prediction probability values among SE, RE, and BIS were found. The prediction probability for all investigated steps of anesthesia did not show significant differences among SE, RE, and BIS. SE, RE, and BIS were superior to mean arterial blood pressure and heart rate.  相似文献   


9.
BACKGROUND: The authors compared the behavior of two calculations of electroencephalographic spectral entropy, state entropy (SE) and response entropy (RE), with the A-Line ARX Index (AAI) and the Bispectral Index (BIS) and as measures of anesthetic drug effect. They compared the measures for baseline variability, burst suppression, and prediction probability. They also developed pharmacodynamic models relating SE, RE, AAI, and BIS to the calculated propofol effect-site concentration (Ceprop). METHODS: With institutional review board approval, the authors studied 10 patients. All patients received 50 mg/min propofol until either burst suppression greater than 80% or mean arterial pressure less than 50 mmHg was observed. SE, RE, AAI, and BIS were continuously recorded. Ceprop was calculated from the propofol infusion profile. Baseline variability, prediction of burst suppression, prediction probability, and Spearman rank correlation were calculated for SE, RE, AAI, and BIS. The relations between Ceprop and the electroencephalographic measures of drug effect were estimated using nonlinear mixed effect modeling. RESULTS: Baseline variability was lowest when using SE and RE. Burst suppression was most accurately detected by spectral entropy. Prediction probability and individualized Spearman rank correlation were highest for BIS and lowest for SE. Nonlinear mixed effect modeling generated reasonable models relating all four measures to Ceprop. CONCLUSIONS: Compared with BIS and AAI, both SE and RE seem to be useful electroencephalographic measures of anesthetic drug effect, with low baseline variability and accurate burst suppression prediction. The ability of the measures to predict Ceprop was best for BIS.  相似文献   

10.
Cerebral monitoring indices are associated with a large degree of inter-patient variability and electrical signal interference during surgery. We designed this clinical study to test the hypothesis that use of the spectral entropy (Entropy) module is associated with less frequent intraoperative interference with the displayed indices than the bispectral index (BIS) monitor when used during general anesthesia with propofol and desflurane. Thirty consenting patients scheduled for major laparoscopic surgery procedures were enrolled in this prospective study. The elapsed time to obtain a baseline index value was recorded, as well as the simultaneous state entropy (SE), response entropy (RE), and BIS values at specific time intervals during the induction, maintenance, and emergence periods in patients administered a standardized general anesthetic technique. During the maintenance period, the changes in these indices were evaluated after a bolus dose of propofol (20 mg IV) and a 2% increase or decrease in the inspired concentration of desflurane. As expected, the baseline SE values were less than the RE and BIS values (88 +/- 2 versus 96 +/- 3 and 96 +/- 4, respectively). However, the SE and RE values correlated with the BIS value during the induction (r = 0.77 and 0.78, respectively) and emergence (r = 0.86 and 0.91, respectively) periods. The area under the receiver operating characteristic curve for detection of consciousness also indicated a similar performance of the SE (0.93 +/- 0.04) relative to the RE (0.98 +/- 0.04) and BIS (0.97 +/- 0.04). During the maintenance period, the responses to changes in propofol and desflurane concentrations were consistent with all three indices. Finally, the entropy indices were less interfered with by the electrocautery unit during the operation (12% versus 62% for the BIS monitor). Because the average selling prices of the Entropy and BIS disposable electrode strips (14.25 dollars versus 14.95 dollars USD, respectively) are comparable, we conclude that the Entropy module is a cost-equivalent alternative to the BIS monitor.  相似文献   

11.
Target controlled infusion (TCI) systems and computer data acquisition software are increasingly used in anesthesia. It was hypothesized that the use of such systems might allow retrieval of information useful to anticipate the effect-site concentrations of propofol at which patients would recover from anesthesia. The goal of the study was to identify variables related to propofol effect-site concentrations at recovery of consciousness (ROC). Sixteen patients with a Glasgow of 15, ASA 1 or 2, subjected to neurosurgical procedures, received TIVA with TCI propofol and remifentanil. Data were collected every 5 seconds from Datex AS3 and Aspect A200XP (BIS). Effect-site TCI was used for propofol (initial effect target 5.0 microg/ml) and for remifentanil (initial plasma target 2.5 ng/ml). All clinical events were noted. Variables possibly related to propofol effect-site concentration at ROC were selected. Data are expressed as mean +/- SD. Effect-site propofol concentration at ROC was 1.3 +/- 0.5 microg/ml. A positive correlation was found between propofol effect-site concentration at ROC and: age (49.3 +/- 17 years) (P = 0.003); mean remifentanil dose during surgery (0.11 +/- 0.05 microg/kg/min) (P = 0.003); mean propofol dose during surgery (0.12 +/- 0.03 mg/kg/min) (P = 0.046); and remifentanil effect-site concentration at ROC (2.85 +/- 2.06 ng/ml) (P = 0.002). Propofol effect-site concentrations were not correlated with: weight, height, LBM, duration of anesthesia, minimum BIS at induction (30.4 +/- 6.8), time till minimum BIS (4.7 +/- 2.2 min), mean and median BIS during surgery (38.2 +/- 4.5 and 37.8 +/- 5.3). BIS-related variables were not useful as ROC predictors. Only drug variables and age correlated with propofol effect-site concentrations at ROC.  相似文献   

12.
Autoregressive modeling with exogenous input of middle-latency auditory evoked potentials (A-Line AEP index, AAI) has been developed for monitoring depth of anesthesia. We investigated the prediction of recovery and dose-response relationship of desflurane and AAI or bispectral index (BIS) values. Twenty adult men scheduled for radical prostatectomy were recruited. To minimize opioid effects, analgesia was provided by a concurrent epidural in addition to the general anesthetic. Electrodes for AAI and BIS monitoring and a headphone for auditory stimuli were applied. Propofol and remifentanil were used for anesthetic induction. Maintenance of anesthesia was with desflurane only. For comparison to AAI and BIS monitor parameters, pharmacokinetic models for desflurane and propofol distribution and effect-site concentrations were used to predict clinical end-points (Prediction probability P(K)). Patients opened their eyes at an AAI value of 47 +/- 20 and a BIS value of 77 +/- 14 (mean +/- sd), and the prediction probability for eye opening was P(K) = 0.81 for AAI, P(K) = 0.89 for BIS, and P(K) = 0.91 for desflurane effect-site concentration. The opening of eyes was best predicted by the calculated desflurane effect-site concentration. The relationship between predicted desflurane effect-site concentration versus AAI and BIS was calculated by nonlinear regression analysis (r = 0.75 for AAI and r = 0.80 for BIS). The correlation between BIS and clinical end-points of anesthesia or the desflurane effect-compartment concentration is better than for the AAI.  相似文献   

13.
目的 探讨罗库溴铵对维族患者全麻诱导时熵指数的影响.方法 择期行全麻手术的维族患者40例,性别不限,年龄20~50岁,体重45~70kg,ASA分级Ⅰ或Ⅱ级,采用随机数字表法,将患者随机分为2组(n=20):生理盐水对照组(NS组)和罗库溴铵组(R组).靶控输注异丙酚,初始血浆靶浓度为2μg/ml,每隔4 min递增0.5μg/ml,直至反应熵(RE)降至45并维持4 min,血浆浓度和效应室浓度平衡时,R组静脉注射罗库溴铵0.6 mg/kg,NS组给予等容量生理盐水,3 min后静脉注射芬太尼3μg/kg诱导气管插管后行机械通气.于麻醉诱导前即刻(T0)、注射罗库溴铵前(T1)、注射后2 min(T2)、气管插管后即刻、1、2和3 min时(T3-6)记录状态熵(SE)和RE,并计算RE-SE差值.结果 与NS组相比,R组T3,4时RE值降低,T2-5时RE-SE差值降低(P<0.05).结论 罗库溴铵可降低维族患者全麻诱导时RE值和RE-SE差值的增高幅度,可能影响熵指数监测麻醉深度的准确性.
Abstract:
Objective To investigate the effect of rocuronium on spectral entropy during induction of general anesthesia in patients of Uygur nstionality. Methods Forty ASA Ⅰ or Ⅱ patients (Uygur nationality) of both sexes, aged 20-50 yr, weighing 45-70 kg, undergoing elective surgery under general anesthesia, were divided into 2 groups ( n = 20 each): normal saline (NS) group and rocuronium group (group R). Anesthesia was induced with target-controlled infusion of propofol. The initial target plasma concentration wan net at 2 μg/ml. The concentration wan then increased by 0.5 μg/ml every 4 min until response entropy (RE) was decreased to 45 and maintained for 4 min. When the plasma concentration was equal to the effect-site concentration, iv rocuronium 0.6 mg/kg was injected in group R, while group NS received the equal volume of NS instead. Fentanyl 3 μg/kg was injected intravenously at 3 min after recuronium administration. The patients were tracheal intubated and mechanically ventilated. State entropy (SE) and RE were recorded immediately before induction (baseline, To), before rocuronium administration (T1), 2 main after rocuronium administration (T2) and at 0, 1, 2 and 3 min after intubation (T3-6). The difference between RE and SE wan calculated. Results The RE value at T3 and T4 and the difference between RE and SE at T2.5 were significantly lower in group R than in group NS ( P < 0.05). Conclusion Rocuronium can decrease the RE value and degree of increase in the difference between RE and SE during induction of general anesthesia in patients of Uygur nationality, which may affect the accuracy of spectral entropy in monitoring the depth of anesthesia.  相似文献   

14.
目的 评价脑电双频谱指数(BIS)监测异丙酚复合瑞芬太尼全麻患儿麻醉深度的准确性.方法 择期手术患儿60例,ASA Ⅰ或Ⅱ级,年龄3~8岁,体重14~40kg,随机分为4组(n=15),人室后开放手背静脉,稳定5 min.C组静脉输注0.9%生理盐水0.2 ml·kg-1·h-1;R1组、R2组和R3组分别静脉输注瑞芬太尼0.1、0.3或0.5 μg·kg-1·min-1,瑞芬太尼或生理盐水输注10 min开始靶控输注异丙酚,起始效应室浓度为1 μg/ml,逐渐递增至2、3、4μg/ml.分别于稳定5min、瑞芬太尼静脉输注10min、异丙酚效应室浓度达到l、2、3、4μg/ml稳定1 min及意识消失时记录BIS和警觉,镇静(OAA/S)评分;记录意识消失时间.采用logistic回归法计算意识消失时的BIS50、BIS95和意识消失时异丙酚的EC50、EC95.BIS与OAA/S评分、异丙酚效应室浓度作直线相关分析.结果 C组、R1.组、R2组和R3组BIS与OAA/S评分均呈正相关,r分别为0.89、0.90、0.87、0.82(P<0.05);BIS与异丙酚效应室浓度均呈负相关,r分别为-0.87、-0.90、-0.87、-0.92(P<0.05);与C组比较,其余3组患儿意识消失时异丙酚效应室浓度降低,意识消失时间缩短,R2组和R3组意识消失时BIS升高,BIS50和BIS95升高,异丙酚EC50和EC95降低(P<0.05);与R1组比较,R2组BIS50和BIS95升高,R3组异丙酚EC50和EC95降低(P<0.05).结论 瑞芬太尼复合异丙酚麻醉下,采用BIS监测患儿麻醉深度存在一定局限性.  相似文献   

15.
Background: The Datex-Ohmeda S/5 Entropy Module (Datex-Ohmeda Division, Instrumentarium Corp., Helsinki, Finland), using time-frequency balanced Spectral Entropy, is a novel tool for monitoring the hypnotic state during anesthesia. The Entropy Module produces two values, State Entropy (SE) and Response Entropy (RE), and in adults, it has been shown to measure reliably the hypnotic effects of various drugs. In children, Spectral Entropy has been only preliminary studied. The authors' aim was to study Spectral Entropy as a marker of hypnotic state during general anesthesia in infants and children.

Methods: Twenty infants (aged 1 month-1 yr) and 40 children (aged 1-15 yr) were anesthetized for surgery using standardized sevoflurane-nitrous oxide-based anesthesia. The relationships between SE, RE, or Bispectral Index (BIS) and (1) a modified Observer's Assessment of Alertness/Sedation Scale, (2) non-steady state end-tidal concentration of sevoflurane, (3) steady state end-tidal concentration of sevoflurane, and (4) hemodynamic values were calculated using prediction probability, nonlinear regression, and correlation coefficients, as appropriate. The performances of SE, RE, and BIS were compared.

Results: The prediction probability values (+/- SEM) of SE, RE, and BIS versus the modified Observer's Assessment of Alertness/Sedation Scale in the induction phase were 0.83 +/- 0.06, 0.88 +/- 0.06, and 0.87 +/- 0.08 for children and 0.76 +/- 0.08,0.79 +/- 0.08, and 0.73 +/- 0.10 for infants; values in the emergence phase were 0.68 +/- 0.05, 0.74 +/- 0.04, and 0.64 +/- 0.05 for children and 0.64 +/- 0.07, 0.69 +/- 0.06, and 0.72 +/- 0.06 for infants, respectively. SE, RE, and BIS values were inversely proportionally related to the end-tidal concentration of sevoflurane for children, but for infants, the correlation was much less clear. No significant correlations were found between SE, RE, or BIS values and the hemodynamic values.  相似文献   


16.
BACKGROUND: The Datex-Ohmeda S/5 Entropy Module (Datex-Ohmeda Division, Instrumentarium Corp., Helsinki, Finland), using time-frequency balanced Spectral Entropy, is a novel tool for monitoring the hypnotic state during anesthesia. The Entropy Module produces two values, State Entropy (SE) and Response Entropy (RE), and in adults, it has been shown to measure reliably the hypnotic effects of various drugs. In children, Spectral Entropy has been only preliminary studied. The authors' aim was to study Spectral Entropy as a marker of hypnotic state during general anesthesia in infants and children. METHODS: Twenty infants (aged 1 month-1 yr) and 40 children (aged 1-15 yr) were anesthetized for surgery using standardized sevoflurane-nitrous oxide-based anesthesia. The relationships between SE, RE, or Bispectral Index (BIS) and (1) a modified Observer's Assessment of Alertness/Sedation Scale, (2) non-steady state end-tidal concentration of sevoflurane, (3) steady state end-tidal concentration of sevoflurane, and (4) hemodynamic values were calculated using prediction probability, nonlinear regression, and correlation coefficients, as appropriate. The performances of SE, RE, and BIS were compared. RESULTS: The prediction probability values (+/- SEM) of SE, RE, and BIS versus the modified Observer's Assessment of Alertness/Sedation Scale in the induction phase were 0.83 +/- 0.06, 0.88 +/- 0.06, and 0.87 +/- 0.08 for children and 0.76 +/- 0.08,0.79 +/- 0.08, and 0.73 +/- 0.10 for infants; values in the emergence phase were 0.68 +/- 0.05, 0.74 +/- 0.04, and 0.64 +/- 0.05 for children and 0.64 +/- 0.07, 0.69 +/- 0.06, and 0.72 +/- 0.06 for infants, respectively. SE, RE, and BIS values were inversely proportionally related to the end-tidal concentration of sevoflurane for children, but for infants, the correlation was much less clear. No significant correlations were found between SE, RE, or BIS values and the hemodynamic values. CONCLUSIONS: Spectral Entropy may be a useful tool for measuring the level of hypnosis in anesthetized children and seems to perform as well as BIS. In infants, the clinical usefulness of both these electroencephalogram-derived methods must be evaluated in further controlled studies.  相似文献   

17.
Koitabashi T  Johansen JW  Sebel PS 《Anesthesia and analgesia》2002,94(6):1530-3, table of contents
The effect of opioid administration on the bispectral index (BIS) during general anesthesia is controversial. Several investigators have reported BIS to be insensitive to opioid addition, whereas others have found a hypnotic response. We designed this study to examine the effect of remifentanil on BIS during combined regional/general propofol anesthesia under steady-state conditions. After Human Investigations Committee approval, 19 healthy ASA physical status I or II patients were enrolled in a prospective experimental design. Regional anesthesia was initiated and general anesthesia induced by using computer-assisted continuous infusion of propofol. Propofol was incrementally adjusted to a BIS of approximately 60. After 20 min at a stable propofol infusion rate, a remifentanil computer-assisted continuous infusion (effect-site target concentration of 0.5, 2.5, and then 10 ng/mL) was sequentially administered at stepped 15-min intervals. BIS decreased from 56 +/- 2 to 44 +/- 1, 95% spectral edge frequency from 17.9 +/- 0.5 Hz to 15.0 +/- 0.4 Hz, heart rate from 84 +/- 5 bpm to 62 +/- 4 bpm, and mean arterial blood pressure from 93 +/- 4 mm Hg to 69 +/- 3 mm Hg with increasing remifentanil concentration. A significant linear correlation between BIS, 95% spectral edge frequency, heart rate, and log (remifentanil effect-site) concentration was found. The change in baseline BIS was relatively modest but significant, suggesting that remifentanil has some sedative/hypnotic properties, or that it potentiates the hypnotic effect of propofol. IMPLICATIONS: This experiment identified a significant, dose-dependent decrease in bispectral index (BIS), 95% spectral edge frequency, heart rate, and mean arterial blood pressure with increasing remifentanil dose. The change in baseline BIS was relatively modest but significant, suggesting that remifentanil has some sedative/hypnotic properties, or that it potentiates the hypnotic effect of propofol.  相似文献   

18.
目的 评价反应熵和状态熵监测全麻患者镇静水平的准确性.方法 择期行腹部手术患者20例,ASAⅠ或Ⅱ级,入室后监测反应熵(RE)、状态熵(SE)及脑电双频谱指数(BIS),静脉注射异丙酚、维库溴铵和芬太尼麻醉诱导,气管插管后机械通气,吸入七氟烷、间断静脉注射维库溴铵和芬太尼维持麻醉.分别于入室时、意识消失前10min、意识消失即刻、气管插管时、手术1 h、意识恢复前10 min、意识恢复即刻、拔管后10 min时记录RE、SE和BIS.结果 RE、SE和BIS在意识改变前后差异均有统计学意义(P<0.05),RE、SE和BIS判断意识消失的临界值分别为76、73和68,灵敏度分别为94%、95%和92%,特异度分别为92%、94%和9l%,临界值判断意识消失的准确度分别为93%、95%、94%;判断意识恢复的临界值分别为82、75和70,灵敏度分别为95%、95%和91%,特异度分别为93%、96%和93%,临界值判断意识恢复的准确度分别为98%、96%和97%.结论 熵指数能够准确地监测全麻患者镇静水平.  相似文献   

19.
AIM: The A-line autoregressive index (AAI) and the Bispectral Index Score (BIS) are two commercially available indexes of anesthetic depth widely used in clinical practice. The aim of the current study was to compare the accuracy of AAI, BIS, Schnider's predicted effect-site concentration of propofol (Ce propofol) to assess depth of anesthesia. METHODS: Forty-four patients scheduled for major elective abdominal surgery received target effect-site controlled infusion of propofol. Target effect-site (Ce propofol) was started at 1.5 mug/mL and increased every 4 min by 1.0 microg/mL until 5.5 microg/mL were achieved. At every step sedation level was estimated, using AAI, BIS, Observer's Assessment of Alertness/Sedation scale (OAA/S), loss of eyelash reflex and Ce propofol. RESULTS: We enrolled 44 patients, 20 males and 24 females, ASA I/II 18/26, 48+/-10 years, 68.2+/-9 kg, 165+/-7.1 cm, body mass index (BMI) 25+/-3.5. At increasing Ce propofol BIS-AAI values decreased progressively (BIS range 97-38) (AAI range 97-17). Values of BIS < or = 50, of AAI < or = 48 and of Ce propofol > or = 5.1 resulted in OAA/S=0, while values of BIS < or = 62, AAI < or = 53 and Ce propofol < or = 3.5 resulted in OAA/S=2. Loss of eyelash reflex occurred when values were BIS < or = 64 and AAI < or 61. CONCLUSION: BIS, AAI, propofol site effect concentration revealed information on sedation level and consciousness but no gold standard yet exists because of consistent overlap between 'conscious' and 'not conscious' states.  相似文献   

20.
目的 评价脑电双频谱指数(BIS)和脑电熵指数监测全麻患者镇痛水平的可行性.方法 择期全麻腹部手术患者26例,随机分为2组(n=13):试验组和对照组.常规监测行硬膜外置管后,试验组硬膜外注入1%利多卡因5 ml,对照组注入等量生理盐水,8 min后测定阻滞平面,根据结果试验组硬膜外追加1%利多卡因和0.5%罗哌卡因的混合制剂5~10 ml,对照组硬膜外追加生理盐水8 ml.麻醉诱导前确保试验组的感觉阻滞节段超过手术切口范围.连接BIS监测仪和脑电熵指数监测仪监测BIS、状态熵(SE)和反应熵(RE).靶控输注异丙酚(初始血浆靶浓度4 μg/ml)和瑞芬太尼(效应室靶浓度2 ng/ml)进行全麻诱导,调整异丙酚靶浓度,维持BIS 40~50.静脉注射罗库溴铵0.9 mg/kg,气管插管,机械通气,试验组停止输注瑞芬太尼,对照组继续输注瑞芬太尼,效应室靶浓度为2 ng/ml.切皮前3 min每分钟记录BIS、RE、SE、HR、SP、DP、MAP,取其平均值作为基础值,切皮后2 min内要求外科医师停止包括使用电刀在内的手术操作,每分钟记录上述指标.2 min后开始使用电刀,进行正常手术操作,并继续每分钟记录上述指标直到切皮后6 min,取其平均值.结果 与基础值比较,切皮后1 min时对照组BIS、RE-SE、SP、DP和MAP均升高(P<0.05),试验组各指标差异无统计学意义(P>0.05),切皮后3~6 min内2组BIS、RE和RE-SE均升高,对照组BP升高(P<0.05).切皮后1min.对于判断镇痛是否足够的准确性,△SP>△RE-SE>△MAP>△BIS,判断准确性均中等.而在电刀干扰时,只有BP的变化可以作为判断指标区分不同的分组,△SP>△MAP.结论 BIS、熵指数和BP并不能反映镇痛水平,但BIS、RE-SE和BP都能够在镇痛不足的情况下对伤害性刺激表现出明显升高.对于镇痛不足的判断准确性,△SP>△RE-SE>△BIS,准确性均中等.  相似文献   