1.
目的 探讨经食管超声心动图(TEE)和经胸超声心动图(TTE)引导Amplatzer封堵器堵闭继发孔型房中隔缺损(ASD)、膜周部室中隔缺损(VSD)的应用价值。方法 术前经TEE筛选符合条件的28例继发孔型ASD,2例膜周部VSD患者,测量ASD的位置、大小及其与周围的关系,VSD的大小位置,在TFE引导下,以球囊测量ASD的最大伸展径,DSA下以造影测量VSD的大小,选择适当型号的封堵器,经导管堵闭ASD和VSD.结果 术前TEE所测的ASD直径11mm~36mm,术中TTE测得ASD的最大伸展径14mm~38mm.前者均小于后者,选择的封堵器的直径为14mm~40mm,28例中,除1例术中转为外科手术治疗,1例未封堵外,余26例均封堵成功,术后即刻、24h、3个月、6个月TTE随访复查均无残余分流及其他并发症。2例VSD术前TEE测量的直径分别为9mm,15mm,术中造影测得的大小为10mm,15mm,两者高度相关。结论 超声引导下经导管置入Amplatzer封堵器治疗ASD,VSD是一种安全、快捷、有效的非手术治疗方法。  相似文献   

2.
目的探讨经食道超声心动图(TEE)和经胸超声心动图(TTE)在Amplatzer封堵器介入治疗房间隔缺损(ASD)的应用价值.方法术前经TEE严格筛选并确认符合条件的ASD患者28例,观测房间隔缺损的位置、大小、形态、延伸状况以及与周围组织的关系.在TTE引导下,以声束测量房间隔缺损的最大伸展轴径,选择不同型号、规格的封堵装置,并在术中准确引导和监测封堵器的放置,评估手术疗效.结果本组28例,1例失败转外科治疗,1例因缺损小无需封堵,其余26例均封堵成功.结论经食道超声心动图(TEE)和经胸超声心动图(TTE)在Amplatzer封堵器介入治疗ASD的应用价值体现在术前病人的选择,术中封堵器放置的引导、监测以及术后疗效的评估上.超声引导下经导管器Amplatzer治疗继发孔型ASD是一种安全、快捷、有效的非手术治疗方法.  相似文献   

3.
经胸超声心动图和X线透视引导下行房间隔封堵术   总被引:13,自引:0,他引:13  
目的 评价在经胸超声心动图 (TTE)和X线透视引导下置入Amplatzer封堵器治疗继发孔型房间隔缺损 (ASD)的可行性和治疗效果。方法 全组 84例 ,TTE测量ASD最大径 :周缘较硬者直接测量ASD最大径 ;周缘较薄或菲薄的边缘 ,剔除极软边缘测量ASD最大径。 4 6例同时球囊测量ASD伸展径。均在TTE及透视监视下封堵ASD。结果  84例ASD术前TTE测量缺损最大径为4 0~ 36 5mm[(18 7± 7 4 )mm]。TTE测量ASD最大径 (18 6± 7 5 )mm与球囊伸展径 (19 2±7 4 )mm差异无显著意义 (t=0 384 ,P >0 0 5 ) ,但两者之间密切相关 (r =0 95 7,P <0 0 1)。 84例封堵器置入均获得成功 ,选用的封堵器直径为 5~ 4 0mm [(2 2 1± 9 7)mm]。初期有 2例术中同时加做经食管超声心动图 (TEE)。术后即刻TTE显示 6例 (7 1% )存在微量至少量残余分流 ;术后 3d还有 3例 (3 6 % )存在微量至少量残余分流 ;术后 6个月仅有 1例 (1 2 % )多发ASD存在微量分流。39例随访 1年以上者右心房、室恢复正常大小 ,未见封堵器及残余分流者。结论 TTE和X线引导下经导管置入Amplatzer封堵器治疗ASD是一种有效、安全、简便可行的方法。缺损较大、边缘较短或TTE不易显示清楚的薄缘ASD ,术前行TEE检查先了解ASD的边缘 ,术中可在TTE和透视指导下完成封堵  相似文献   

4.
目的探讨彩色多普勒超声心动图(TTE)在小儿继发孔房间隔缺损(ASD)诊治中的作用。方法筛选98例小儿继发孔ASD患者,封堵术前应用二维超声心动图(2DE)观察ASD位置、大小和残余边缘长度。应用彩色多普勒血流显像(CDFI)观察过房间隔分流束和各瓣膜反流情况。应用连续波多普勒(CW)估测肺动脉压力。封堵术中应用2DE监视封堵器位置是否正常,应用CDFI观察是否有残余分流及是否引起或加重瓣膜反流。封堵术后应用2DE测量心腔内径的变化,观察封堵器是否有移位、脱落。应用CDFI观察是否有残余分流及瓣膜反流情况。应用CW估测肺动脉压力变化。结果本组98例小儿继发孔ASD患者经TEE术前筛选适应证、术中监测和术后疗效判断,实施ASD封堵术全部获得成功,包括合并畸形全部实施介入治疗,治疗效果满意。结论彩色多普勒超声心动图在小儿继发孔房间隔缺损的术前诊断、术中监测及术后疗效判断中具有重要的临床作用。  相似文献   

5.
目的:评价经胸超声心动图(TTE)、经食道超声心动图(TEE)、三维超声心动图(3DE)在经心导管关闭膜周部室间隔缺损(PMVSD)中的应用价值。方法:拟行经心导管关闭PMVSD的258例患者为研究对象,常规检查建立诊断后,在超声及X线检测下经心导管堵塞室缺,并在术后2h、1个月、3个月、6个月、12个月进行TTE检查。结果:258例患者术前均行TTE检查,46例导管室行TEE检查,38例术中行3DE检查。由于术前超声心动图漏诊或不准确,20例(7.8%)堵塞失败,238例成功,成功率92.2%。超声测量PMVSD大小7.1±1.72mm,分流口(Dv)4.1±1.51mm,边缘距主动脉右冠瓣4.2±2.21mm,使用装置大小(De)4~12mm,平均6.4mm;装置大小与分流口间关系为De=1.04Dv 1.87。术后超声检查10min、2h、1个月、3个月残余分流率分别为21.8%、6.7%、1.2%、0.8%。结论:超声心动图检查可以准确地显示PMVSD的大小、部位及其边缘的解剖形态,在术前病例的初步筛选、术中监测、堵塞器的选择、即刻效果判断及术后随访中起重要作用,是经心导管堵塞PMVSD安全、有效的监测方法。  相似文献   

6.
目的:探讨二维超声心动图(2DE)、实时三维超声心动图(RT-3DE)在定量评价冠心病患者左室心肌质量(LVM)的价值。方法:分别采用2DE和RT-3DE测量34例冠心病患者LVM和左室心肌质量指数(LVMI),并进行比较。结果:2DE测定的LVM和LVMI大于RT-3DE测值,2种方法测值之间差异有统计学意义(P0.05)。结论:RT-3DE能准确测量冠心病患者LVM,2DE高估冠心病患者LVM。  相似文献   

7.
目的:探讨M型超声心动图(MME)、二维超声心动图(2DE)、实时三维超声心动图(RT-3DE)在定量评价冠心病患者左室收缩功能(LVSF)的应用价值。方法:分别采用MME、2DE、RT-3DE测量34例冠心病患者左室舒张末期容积(LVEDV)、收缩末期容积(LVESV)、每搏量(SV)和射血分数(EF),并在三种方法间进行比较。结果:MME和2DE两种方法测定的LVEDV、LVESV、SV大于RT-3DE测值,而EF小于RT-3DE测值,MME和2DE两种方法与RT-3DE各测值之间差异均有统计学意义(P0.05)。MME、2DE两种方法间差异无统计学意义(P0.05)。结论:RT-3DE能准确评价冠心病患者LVSF状况;MME和2DE高估LVEDV、LVESV、SV,低估EF。  相似文献   

8.
目的探讨经胸彩色多普勒超声心动图(TTE)在小儿继发孔房间隔缺损(ASD)封堵术中的应用价值。方法68例小儿ASD患者,封堵术前应用TTE筛选适应证,应用二维超声心动图(2DE)观察ASD位置、测量ASD大小和残余边缘长度。应用彩色多普勒血流显像(CDFI)显示过ASD分流束和各瓣膜反流情况。应用连续波多普勒(CW)估测肺动脉压力。封堵术中应用2DE监视封堵器位置是否正常,应用CDFI观察是否有残余分流。封堵术后应用2DE测量心腔内径的变化,观察封堵器是否有移位、脱落。应用CDFI观察是否有残余分流,应用CW估测肺动脉压力变化。结果本组68例小儿ASD患者经TEE术前筛选适应证、术中监测和术后疗效判断,实施ASD封堵术全部获得成功,包括合并畸形全部实施介入治疗,治疗效果满意。结论因小儿ASD患者行经食管超声心动图检查受限制,只能依靠TTE检查。因此TTE在小儿ASD封堵术中具有重要临床价值。  相似文献   

9.
目的 分析和总结房间隔缺损(ASD)堵闭术中Amplatzer封堵器的选择方法。方法 30例ASD患者,术前经胸超声心动图(TTE)或食管超声心动图(TEE)检查明确ASD大小及周围结构,初步估计封堵器型号。术中再次依据TTE、水球囊测量(34mm以上ASD除外)确定合适的Amplatzer伞进行ASD封堵,并依靠TTE明确封堵效果。结果 TTE显示30mm以下的ASD直径12~2 8(18.4 1±6 .16 )mm ,水球囊测量值为14~30 (2 2 .84±6 .19)mm ,选择封堵伞直径为14~30 (2 4 .6 9±6 .99)mm ,TTE显示30mm以上ASD有12例患者,其中选择4 0mm封堵器6例,4 2mm封堵器1例。30例ASD患者,2 8例封堵器置入获得成功,1例双孔ASD患者,一伞堵双孔,术后未见分流,1例巨大ASD ,封堵失败,1例术中封堵器脱落,转胸外科手术,其余患者未发生任何并发症。结论 应用TTE可较准确的独立估测ASD直径的球囊测量值,ASD直径的水球囊测量值应作为TTE示30mm以下ASD选择封堵器的“金标准”;30mm以上ASD患者可直接用TTE测量值指导封堵器选择。TEE可作为多孔ASD及TTE显示不清ASD患者的重要补充检查  相似文献   

10.
 目的 评价经胸超声心动图(TTE)在房间隔缺损(ASD)介入治疗中的价值。方法 30例ASD患者应用TTE行术前筛选、术中监测和术后随访。结果用TTE术前检查ASD大小8~36(25.0±6.8)mm,选用Amplatzer封堵器大小为12~40(28.2±7.0)mm。TTE测量ASD大小与封堵器大小相关良好(r=0.94,P<0.01)。硬缘ASD的封堵器选择比超声所测ASD大1~6mm。软缘ASD通常不考虑摆动较大部分为有效缘而予以去除,封堵器选择比超声所测ASD大7~13mm。随访6个月封堵器牢固,无脱落及残余分流。结论 TTE术前检查及术中指导ASD封堵是一种可行、简便而有效的方法。  相似文献   

11.
经胸实时三维超声心动图在房间隔缺损诊疗中的应用价值   总被引:4,自引:0,他引:4  
目的:探讨实时三维超声心动图在房间隔缺损诊疗中的l临床应用价值。方法:应用Philipa Sonoa 7500实时三维超声成像系统获取32例先天性房间隔缺损息者的三维数据库,利用三维数据工作站对缺损大小进行测量分析。部分病例的三维测量值与二维经胸和(或)经食道超声测量值、球囊伸展径和(或)手术结果对照。对其中4例中央型房缺患者在实时三维超声心动图监测下,经心导管行房缺封堵术。结果:实时三维成像能从多个视角、甚至模拟手术路径立体显示房间隔缺损的金貌,包括缺损的整体形态、部位、大小、残端,以及与周边组织的毗邻关系;同二维超声所测直径相比,三维超声测量结果与介入或手术结果具有更好的相关性(r=0.97va r=0.88),并能更准确引导房间隔介入手术。结论:与二维超声心动图比较,实时三维超声心动图反映了房间隔缺损的立体空间结构,可对缺损大小进行准确的定量分析。同时在引导介入手术中提供快速而准确的监测手段,具有重要的临床应用潜力。  相似文献   

12.
邓劲松  王洁 《武警医学》2005,16(7):507-509
 目的探讨经胸超声心动图(Transthoracic echocardiography,TTE)监测经导管引导Amplatzer封堵器介入治疗房间隔缺损(Atrial septal defect,ASD)的临床应用价值.方法选择经TTE检查确诊ASD适合做封堵术的9例患者,术前多个切面综合测量ASD的直径,然后在术中监测经导管引导Amplatzer封堵器治疗ASD的全过程,封堵术后即刻、1周内、1个月、3个月、6个月、1 a随访TTE,观察封堵效果、封堵器周边有无分流.结果9例ASD患者,除2例因缺损口过大(最大伸展径大于38 mm),选用最大的封堵器无效而放弃封堵外,其余7例均成功封堵,术后TTE未见残余分流.结论TTE对ASD封堵术前病例的选择,封堵术中监测及封堵术后疗效评价等均有一定的临床应用价值.  相似文献   

13.
目的研究非常规方法选择Amplatzer治疗房间隔缺损及动脉导管未闭的可行性。方法14例II孔型ASD和1例动脉导管未闭,经术中常规右心导管检查,测量右室与肺动脉压力,经导引钢丝导入球囊导管测AS最大伸展直径,用体表经胸超声心动图(TTE)或经食管超声(TEE)测量房间隔直径及确定ASD的位置及大小,根据球囊最大伸展直径选择应用等于或大于其1~2mm型号的国产ASD和PDA封堵器。结果15例患者应用15个封堵器均获成功,成功率为100%,无并发症,亦无残余分流。结论国产封堵器具有操作简便、效果可靠、成功率高、安全等优点,应用封堵器封堵ASD和PDA是安全有效的。  相似文献   

14.
Purpose: Accurate evaluation of the size, location and adjacent structure of an atrial septal defect (ASD) is very important in the selection of patients for further management. We directly compared the utility of transthoracic echocardiography, angiocardiography, balloon sizing, and intracardiac ultrasound (ICUS) in the detection of ASD. Methods: Twenty-one children underwent an ICUS study of ASD after routine clinical and laboratory studies. All patients had received transthoracic echocardiography (TTE), cardiac catheterization, cineangiography, and balloon sizing before the ICUS to evaluate the ASD. Results: There was a significant correlation between the ICUS-derived ASD diameter and the other methods (p < 0.001). The balloon-sizing diameter was estimated by the equation: TTE diameter × 1.09 + 3.9 mm. There was a good correlation between the predicted and measured balloon-sizing diameter (r = 0.963; p < 0.001). Conclusion: It is worthwhile spending a few minutes to perform ICUS during cardiac catheterization since it will provide more detailed information on and high resolution images of atrial septal morphology, especially for patients undergoing transcatheter closure by device.  相似文献   

15.
PURPOSE: To compare the accuracy of planimetric and continuity equation measurements of aortic valve area (AVA) by cardiac MR (cMR) to each other and against transthoracic (TTE) and transesophageal (TEE) echocardiography. MATERIALS AND METHODS: A total of 31 patients (21 men, mean age = 67 +/- 13 years) with aortic stenosis (AS) and 16 controls (12 men, mean age = 57 +/- 14 years) underwent measurement of AVA by planimetric and continuity equation cMR. Measurements were compared to TEE planimetry and continuity equation TTE. RESULTS: AVA by continuity equation cMR correlated highly to continuity equation TTE (r = 0.98) and was not significantly different (1.8 +/- 1.3 cm2 vs. 1.8 +/- 1.4 cm2, P = 0.62). Similarly, AVA by cMR planimetry was not statistically different from TEE planimetry (2.1 +/- 1.7 cm2 vs. 2.1 +/- 1.6 cm2, P = 0.34) and correlated highly (r = 0.98). Yet planimetric measurements of AVA by cMR and TEE were significantly higher than AVA by continuity equation cMR (P < 0.001 and P < 0.001, respectively) and TTE (P < 0.001 and P < 0.001, respectively). CONCLUSION: Both planimetry and continuity equation-based measurements of AVA by cMR are equally accurate. However, similar to TEE, cMR AVA is larger by planimetry than by continuity equation. This is consistent with the contention that the anatomical maximum opening of a stenotic aortic valve is larger than the size of the functional vena contracta.  相似文献   

16.
经胸超声心动图在先天性心脏病介入封堵术中的应用   总被引:1,自引:0,他引:1  
目的 探讨经胸超声心动图(TTE)在先天性心脏病介入封堵术中的应用价值.方法 TTE筛选出26例房间隔缺损(ASD)、23例室间隔缺损(VSD)以及16例动脉导管未闭(PDA)的先天性心脏病患者行经导管国产封堵器介入封堵治疗,并应用TTE在封堵术中监测及在术后进行疗效评估.结果 共61例患者成功地进行了介入封堵治疗,术后即刻TTE及X线造影均未见残余分流,各瓣膜未见病理性反流.术后1个月及3个月TTE复查,封堵器位置良好,无残余分流.3例室缺患者术后第2天出现不同程度的传导阻滞,经治疗后好转.2例ASD、2例VSD及1例PDA未完成封堵.总成功率为93.8%(61/65).结论 TTE在先天性心脏病介入封堵治疗术的术前病例筛选、术中监测和术后疗效评价中有重要价值.  相似文献   

17.
目的探讨超声心动图(UCG)结合右心声学造影(c TTE)在卵圆孔未闭(PFO)中的应用价值,为临床诊断和治疗提供早期参考依据。方法选取沈阳军区总医院自2015年1月至2015年12月住院治疗的怀疑存在PFO的患者51例,行经胸超声心动图(TTE)检查明确是否存在房水平分流,存在者测量分流的大小;对于TTE显示房水平分流不明显的患者行经食管超声心动图(TEE)检查,观察房间隔卵圆孔的形态以及是否存在房水平分流,存在者测量分流的大小;对于存在房水平分流的患者行c TTE检查,观察左心内显示微气泡的数量及出现微气泡的时间,根据分流量分成0、Ⅰ、Ⅱ、Ⅲ级。结果 TTE检出存在房水平分流27例,TEE检出存在房水平分流11例,无分流13例;c TTE检测存在房水平分流38例中,分流量0级3例、Ⅰ级5例、Ⅱ级21例、Ⅲ级9例。TTE、TEE测量的PFO直径与c TTE检测PFO分流等级间存在明显的相关性(r=0.876,P<0.05)。结论 UCG结合c TTE的应用,可以明确PFO的大小、分流量以及微气泡出现的时间,为临床的诊断和治疗提供参考依据。  相似文献   

18.
目的:探讨经胸超声心动图(TTE)预测房间隔缺损(ASD)封堵器直径的价值。方法:使用VIVID7超声仪分别在主动脉根部短轴切面、胸骨旁四腔心切面及剑突下两心房切面测量ASD直径,房间隔总长度及残余房间隔各硬缘长度。预选封堵器直径为测得的最大ASD直径加4mm。在X线透视和TTE监测下行ASD封堵术。结果:14例ASD手术当日TTE测量缺损最大径为17~31mm,术中所用封堵器直径为22~40mm,二者间相关性良好(r=0.91)。除两倒术中试用不同型号封堵器外,其余均以TTE测得的最大ASD直径加4mm选用封堵器型号,一次成功。结论:TTE能准确预测ASD封堵器型号,从而大大节省手术操作时间。  相似文献   

19.
PURPOSE: To prospectively compare the accuracy of multidetector computed tomographic (CT) measurements of the aortic valve area (AVA) with transesophageal echocardiography (TEE) and cine magnetic resonance (MR) measurements of this area for preoperative examination of patients undergoing cardiac surgery, with transthoracic echocardiography (TTE) as the reference standard. MATERIALS AND METHODS: After giving informed consent for the institutional review board-approved study protocol, 48 patients (33 men, 15 women; mean age, 62 years+/-13 [standard deviation]) with (n=27) or without (n=21) aortic stenosis underwent multidetector CT, cine MR, TTE, and TEE before undergoing cardiac surgery. AVAs derived with manual planimetry by using cine short-axis multidetector CT, MR, and TEE images obtained through the aortic valve were compared among each other and with AVAs measured by using continuity equation TTE at regression and Bland-Altman analyses. The diagnostic accuracy of multidetector CT for detection of aortic stenosis was compared with that of TTE by using kappa statistics and receiver operating characteristic curves. RESULTS: Multidetector CT-derived AVA correlated highly with MR-derived (r=0.98, P<.001), TEE-derived (r=0.98, P<.001), and TTE-derived (r=0.96, P<.001) AVA. Multidetector CT planimetry AVAs (mean AVA+/-standard deviation, 2.5 cm2+/-1.7) were not significantly different from MR planimetry (2.4 cm2+/-1.8, P>.99) or TEE planimetery (2.5 cm2+/-1.7, P=.21) AVAs, but they were significantly larger than TTE-derived AVAs (2.0 cm2+/-1.5, P<.001). With TTE as the reference standard, multidetector CT correctly (kappa=0.88, P<.001) depicted all 21 normal, six of eight mildly stenotic (AVA>or=1.2 cm2 and <2.0 cm2), seven of eight moderately stenotic (AVA>or= 0.8 cm2 and <1.2 cm2), and 10 of 11 severely stenotic (AVA<0.8 cm2) valves. It also correctly depicted all 14 bicuspid valves identified with TEE, eight of which were missed with TTE. CONCLUSION: Multidetector CT enables accurate noninvasive assessment of the AVA.  相似文献   

20.
 目的 探讨单心动周期实时三维经胸超声心动图在小儿房间隔缺损诊疗中的应用价值。方法 应用GE Vivid E9超声诊断仪、M5S广角及4V-D四维探头对27例先天性房间隔缺损(atrial septal defect,ASD)患者,3~15岁,平均(9.0±5.5)岁,进行常规二维经胸超声及单心动周期实时三维超声经胸心动图检查,明确诊断。并对缺损大小进行测量分析,将二维、三维测量值与手术结果对照。结果 单心动周期实时三维超声心动图能从多个视角,模拟手术路径立体显示房间隔全貌,包括缺损的整体形态、部位、大小,以及毗邻关系;实时三维超声、二维超声同手术结果相对比:测量ASD最大长轴径分别为(29.7±7.3)mm、(33.6±9.2)mm、(31.2±9.2)mm ,实时三维超声较二维超声与手术结果具有更好的相关性(r分别为0.96,0.82)。结论 单心动周期实时三维经胸超声心动图能够模拟手术野,为ASD的测量提供了准确可靠的新方法,具有重要的临床应用潜力。  相似文献   