首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Purpose

The purpose of the study was to determine whether the hinge axis registration and the transfer modality (facebow transfer vs. average mounting) from the subject to the articulator affect the three-dimensional condylar shift between the centric relation (CR) and the maximum intercuspation (MI) position.

Material and Methods

The study was comprised of 32 fully dentate subjects (16 male and 16 female). Only the asymptomatic participants with normal occlusal relations (Angle class I) aged 20 - 33 (mean age 22.6 ± 4.7) met the inclusion criteria. Three-dimensional condylar shift (anteroposterior, superoinferior and mediolateral shift) between the centric relation position (CR) and the maximum intercuspation (MI) position was analyzed by means of Mandibular Position Indicator (SAM Prazisionstechnik GmbH, Muenchen, Germany).

Results

The average three-dimensional condylar shift was 0.13 ± 0.12 mm for facebow transfer and 0.22 ± 0.23 mm for average mounting. There were no statistically significant differences noted between genders. The results of the Mann-Whitney test showed statistically significant differences for anteroposterior and superoinferior condylar shift (P < 0.001). However, the difference in the mediolateral shift was not statistically significant.

Conclusions

In order to find discrepancies within the three-dimensional condylar shift, facebow transfer proved to be more accurate than the average mounting in the semi-adjustable articulator. However, the average value of three-dimensional shifts of the condyle did not differ from normal values and they did not have clinical significance. Thus, both ways of transfer modalities (facebow transfer and average mounting) in asymptomatic subjects with normal occlusion can be considered reliable.Key words: Hinge axis, facebow transfer, average mounting, centric relation, maximum intercuspation, mandibular position indicator  相似文献   

2.

BACKGROUND

Mandibular displacement is a common complication of condylar fracture. In the mandibular displacement due to condylar fracture, it is difficult to restore both esthetics and function without using orthognathic surgery.

CASE DESCRIPTION

This clinical report described a full mouth rehabilitation in the patient with bilateral condylar fractures and displaced mandible using bilateral sagittal split ramus osteotomy (BSSRO) and simultaneous dental implant surgery. Mandibular position was determined by model surgery through the diagnostic wax up and restoration of fractured teeth. The precise amount of the mandibular shift can be obtained from the ideal intercuspation of remaining teeth.

CLINICAL IMPLICATION

Mandibular displacement by both condylar fractures can be successfully treated by orthognathic surgery. Determination of occlusal plane and visualization from diagnostic wax up are mandatory for mandibular repositioning of model surgery. Stable occlusion and regular recall check up are needed for long-term outcome.  相似文献   

3.

PURPOSE

The purpose of this study was to develop a dental image processing system using a three-dimensional (3D) camera and stereovision technology. The reliability of the system for measuring axial wall convergence angles was evaluated.

MATERIALS AND METHODS

The new system predicted 3D coordinate points from 2D images and calculated distances and angles between points. Two examiners measured axial wall convergence angles for seven artificial abutments using a traditional tracing-based method (TBM) and the stereovision-based method (SVBM). Five wax abutment models of simplified abutment forms were made and axial wall convergence angles of wax models were measured by both methods. The data were statistically analyzed at the level of significance, 0.05.

RESULTS

Intraclass correlation coefficients showed excellent intra-examiner and inter-examiner reliabilities for both methods. Bland-Altman plots and paired t-tests showed significant differences between measurements and true values using TBM; differences were not significant with SVBM.

CONCLUSION

This study found that the SVBM reflected true angle values more accurately than a TMB and illustrated an example of 3D computer science applied to clinical dentistry.  相似文献   

4.
To evaluate and compare the centric relation and horizontal condylar guidance using interocclusal wax and extra oral Gothic arch methods and subjective evaluation of dentures thus fabricated. Centric relation and horizontal condylar guidance was recorded by using interocclusal wax and gothic arch tracing in 28 completely edentulous patients. These records were transferred to the articulator and difference in both values was recorded. After that patients were divided in two groups according to the centric relation and horizontal condylar guidance recording method used to achieve balanced occlusion. Response of the dentures was subjectively evaluated using “Woelfel subjective evaluation criteria”. Centric relation recorded by both the methods did coincide in 7.14 % of patients. Centric relation recorded by interocclusal wax was posterior to Gothic centric relation in 21.43 % of patients, and anterior to Gothic centric relation in 71.42 % patients. Gothic arch tracings gave higher mean guidance values on both the sides as compared to protrusive wax record in all the subjects, although the difference was statistically insignificant (P > 0.05). Subjective evaluation showed statistical insignificance for all the parameters in both groups. Gothic arch method records the centric relation at a more posterior position than the Static method, but it does not make any difference in clinical performance of the complete denture. Horizontal condylar guidance angle was approximately similar by both the methods.  相似文献   

5.

Statement of problem

Currently, dental articulators can recreate mandibular movements and occlusal contacts. However, whether virtual articulators can also provide information about occluding dental surfaces, functional movements, and the mandibular condyles is unclear.

Purpose

The purpose of this in vitro study was to evaluate the occluding surfaces on dental casts obtained from a patient and approximate them to a hemispherical contact model. Both models were tested by digitizing the Dentatus ARL dental articulator.

Material and methods

A combination of photogrammetry and structure from motion methods were used to scan a Dentatus ARL articulator and representative dental casts. Using computer-aided engineering and finite element analysis, contact points and action vectors to the forces on occluding surfaces and condyles were obtained for cast and hemispherical models. This experiment was performed using centric occlusion and 3 different condylar inclinations. The Kruskal-Wallis 1-way analysis of variance on ranks test was used to allow all pairwise comparisons between condylar inclination and mechanical action vector values in each location (α=.05).

Results

Action vectors from the cast model and each location of the hemispherical model were calculated to show the mechanical consequences and the similarity among models. Overall, no significant differences were observed for action vectors (A20 versus A40 versus A60) at each location (dental cast/hemisphere, right condylar, and left condylar) in the analysis of dental casts and the hemisphere model (.382≤P≤.999).

Conclusions

This study provided graphical information that may assist the dental professional in determining which occlusal contacts should be modified to attain condylar and balanced centric occlusion.  相似文献   

6.

PURPOSE

The purpose of this report was to evaluate the effect of the fabrication method and material type on the fracture strength of provisional crowns.

MATERIALS AND METHODS

A master model with one crown (maxillary left second premolar) was manufactured from Cr-Co alloy. The master model was scanned, and the data set was transferred to a CAD/CAM unit (Yenamak D50, Yenadent Ltd, Istanbul, Turkey) for the Cercon Base group. For the other groups, temporary crowns were produced by direct fabrication methods (Imident, Temdent, Structur Premium, Takilon, Systemp c&b II, and Acrytemp). The specimens were subjected to water storage at 37℃ for 24 hours, and then they were thermocycled (TC, 5000×, 5-55℃) (n=10). The maximum force at fracture (Fmax) was measured in a universal test machine at 1 mm/min. Data was analyzed by non-parametric statistics (α=.05).

RESULTS

Fmax values varied between 711.09-1392.1 N. In the PMMA groups, Takilon showed the lowest values (711.09 N), and Cercon Base showed the highest values (959.59 N). In the composite groups, Structur Premium showed the highest values (1392.1 N), and Acrytemp showed the lowest values (910.05 N). The composite groups showed significantly higher values than the PMMA groups (P=.01).

CONCLUSION

Composite-based materials showed significantly higher fracture strengths than PMMA-based materials. The CAD-CAM technique offers more advantages than the direct technique.  相似文献   

7.
Statement of problemProgramming semiadjustable and fully adjustable articulators involves time-consuming clinical steps which can be avoided if an accurate radiographic method can accurately determine the condylar guidance angles.PurposeThe purpose of this clinical study was to compare the sagittal condylar guidance in dentate individuals as determined by a clinical method, protrusive interocclusal record, and a radiographic method, cone beam computed tomography. If the methods show a correlation, then cone beam computed tomography can be used as a time-saving method of programming an articulator for patients requiring a cone beam computed tomography scan.Material and methodsA total of 40 participants (20 men and 20 women) within the 20 to 40 years age group were enrolled according to the inclusion and exclusion criteria. Cone beam computed tomography scans were obtained, and by using an appropriate software program, the sagittal condylar guidance was measured for both sides. A protrusive interocclusal record was obtained by using polyvinyl siloxane material. The maxillary cast of each participant was mounted on a semiadjustable articulator with a facebow transfer, and the mandibular cast was mounted with a maximum intercuspal record. The protrusive record was then transferred to the articulator for programming.ResultsThe right and left sagittal condylar guidance values obtained from both the protrusive interocclusal record and cone beam computed tomography method were comparable, with no significant differences (P>.05). The difference in condylar inclination values for both sexes obtained from both methods for both sides were not statistically different (P>.05). With increasing age, condylar inclination values obtained from both methods tended to decrease. The values for sagittal condylar guidance obtained from both methods (protrusive interocclusal record and cone beam computed tomography) were comparable and correlated.ConclusionsCone beam computed tomography measurement involves stable bony landmarks and can be standardized, whereas clinical methods are time consuming and can provide inaccurate results because of the instability of the materials used to register the maxillomandibular relationship. Thus, cone beam computed tomography can be used to obtain the sagittal horizontal guidance for programming semiadjustable and fully adjustable articulators for patients requiring a cone beam computed tomography scan.  相似文献   

8.

PURPOSE

The purpose of this study was to evaluate whether surface treatments affect the translucency of laminate veneers with different shades and thicknesses.

MATERIALS AND METHODS

A total of 224 disc-shaped ceramic veneers were prepared from A1, A3, HT (High Translucent) and HO (High Opaque) shades of IPS e.max Press (Ivoclar Vivadent) with 0.5 mm and 1.0 mm thicknesses. The ceramics were divided into four groups for surface treatments. Group C: no surface treatments; Group HF: etched with hydrofluoric acid; Group SB: sandblasted with 50-µm Al2O3; and Group L; irradiated with an Er;YAG laser. A translucent shade of resin cement (Rely X Veneer, 3M ESPE) was chosen for cementation. The color values of the veneers were measured with a colorimeter and translucency parameter (TP) values were calculated. A three-way ANOVA with interactions for TP values was performed and Bonferroni tests were used when appropriate (α=0.05).

RESULTS

There were significant interactions between the surface treatments, ceramic shades and thicknesses (P=.001). For the 0.5-mm-thick specimens there were significant differences after the SB and L treatments. There was no significant difference between the HF and C treatments for any shades or thicknesses (P>.05). For the 1-mm-thick ceramics, there was only a significant difference between the L and C treatments for the HT shade ceramics (P=.01). There were also significant differences between the SB and C treatments except not for the HO shades (P=.768).

CONCLUSION

The SB and L treatments caused laminate veneers to become more opaque; however, HF treatment did not affect the TP values. When the laminate veneers were thinner, both the shade of the ceramic and the SB and laser treatments had a greater effect on the TP values.  相似文献   

9.

PURPOSE

The purpose of this study was to to analyze the effect of Type 2 diabetes on tooth mortality, implant treatment and prosthetic status.

MATERIALS AND METHODS

275 Type 2 diabetics and 300 non-diabetics, aged 40-80 years were selected for analysis. The assessment of number of teeth, missing teeth, fixed prostheses (bridge pontics), implants using panoramic radiographs and dental records were carried out.

RESULTS

Diabetes mellitus (DM) patients had a higher number of missing teeth (P<.05) and placed implants (P=.074), age (P<.05), male gender percentage (P=.042), smoker percentage (P<.05) than non-DM patients. In univariate analysis, the patients in older group showed significantly higher number of tooth loss rate at the first dental examination than the patients in younger group. Tooth loss rate of smokers did not show higher value than that of non-smokers. When multiple variables including DM, age, smoking, gender were considered together, diabetics and older group patients showed significantly higher tooth loss rate at the first dental examination than non-diabetics and younger group patients, respectively. Smokers and male group did not show a significant difference than non-smokers and female group, respectively.

CONCLUSION

Tooth mortality and implant treatment rate were significantly higher in the DM group as indicated by univariate and multivariate logistic regression analysis. Old age groups showed significantly higher odds ratios and tooth loss rate. As diabetics showed the higher tooth loss rate than non-diabetics, diabetics also had more implant restorations than non-diabetics.  相似文献   

10.

PURPOSE

Bonding agents (BA) are the crucial weak link of composite restorations. Since the commercial materials'' compositions are not disclosed, studies to formulize the optimum ratios of different components are of value. The aim of this study was to find a proper formula of BAs.

MATERIALS AND METHODS

This explorative experimental in vitro study was composed of 4 different sets of extensive experiments. A commercial BA and 7 experimental formulas were compared in terms of degree of conversion (5 experimental formulas), shear bond strength, mode of failure, and microleakage (3 experimental formulas). Statistical analyses were performed (α=.05). The DC of selected formula was tested one year later.

RESULTS

The two-way ANOVA indicated a significant difference between the shear bond strength (SBS) of two tissues (dentin vs. enamel, P=.0001) in a way that dentinal bonds were weaker. However, there was no difference between the four materials (P=.283). The adhesive mode of failure was predominant in all groups. No differences between the microleakage of the four materials at occlusal (P=.788) or gingival (P=.508) sites were detected (Kruskal-Wallis). The Mann-Whitney U test showed a significant difference between the microleakage of all materials (3 experimental formulas and a commercial material) together at the occlusal site versus the gingival site (P=.041).

CONCLUSION

A formula with 62% bisphenol A-glycidyl methacrylate (Bis-GMA), 37% hydroxy ethyl methacrylate (HEMA), 0.3% camphorquinone (CQ), and 0.7% dimethyl-para-toluidine (DMPT) seems a proper formula for mass production. The microleakage and SBS might be respectively higher and lower on dentin compared to enamel.  相似文献   

11.

PURPOSE

The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading.

MATERIALS AND METHODS

Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at 106 cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey''s test (5%).

RESULTS

The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000).

CONCLUSION

The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.  相似文献   

12.

PURPOSE

Heat of composite polymerization (HP) indicates setting efficacy and temperature increase of composite in clinical procedures. The purpose of this in vitro experimental study was to evaluate the effects of 5 temperatures on HP of two new composites.

MATERIALS AND METHODS

From each material (Core Max II [CM] and King Dental [KD]), 5 groups of 5 specimens each were prepared and their total HPs (J/gr) were measured and recorded, at one of the constant temperatures 0℃, 15℃, 23℃, 37℃ and 60℃ (2 × 5 × 5 specimens) using a differential scanning calorimetry (DSC) analyzer. The data were analyzed using a two-way ANOVA, a Tukey''s test, an independent-samples t-test, and a linear regression analysis (α=0.05).

RESULTS

No polymerization reactions occurred at 0℃; then this temperature was excluded from statistical analyses. The mean HP of the remaining 20 KD specimens was 20.5 ± 14.9 J/gr, while it was 40.7 ± 12.9 J/gr for CM. The independent-samples t-test showed that there were significant differences between the HP of the two materials at the temperatures 15℃ (P=.0001), 23℃ (P=.0163), 37℃ (P=.0039), and 60℃ (P=.0106). Linear regression analysis showed statistically significant correlations between environment temperatures and HP of CM (R2=0.777).

CONCLUSION

Using CM is advantageous over conventional composite because of its better polymerization capacity. However due to its high HP, further studies should assess its temperature increase in vivo. Preheating KD is recommended. Refrigerating composites can negatively affect their polymerization potential.  相似文献   

13.

PURPOSE

This study aimed to evaluate the fit of zirconia ceramics before and after veneering, using 3 different veneering processes (layering, press-over, and CAD-on techniques).

MATERIALS AND METHODS

Thirty standardized zirconia CAD/CAM frameworks were constructed and divided into three groups of 10 each. The first group was veneered using the traditional layering technique. Press-over and CAD-on techniques were used to veneer second and third groups. The marginal gap of specimens was measured before and after veneering process at 18 sites on the master die using a digital microscope. Paired t-test was used to evaluate mean marginal gap changes. One-way ANOVA and post hoc tests were also employed for comparison among 3 groups (α=.05).

RESULTS

Marginal gap of 3 groups was increased after porcelain veneering. The mean marginal gap values after veneering in the layering group (63.06 µm) was higher than press-over (50.64 µm) and CAD-on (51.50 µm) veneered groups (P<.001).

CONCLUSION

Three veneering methods altered the marginal fit of zirconia copings. Conventional layering technique increased the marginal gap of zirconia framework more than pressing and CAD-on techniques. All ceramic crowns made through three different veneering methods revealed clinically acceptable marginal fit.  相似文献   

14.

PURPOSE

There is insufficient data regarding the durability of porcelain laminate veneers bonded to existing composite fillings. The aim of the present study was to evaluate the fracture resistance and microleakage of porcelain laminate veneers bonded to teeth with existing composite fillings.

MATERIALS AND METHODS

Thirty maxillary central incisors were divided into three groups (for each group, n=10): intact teeth (NP), teeth with class III composite fillings (C3) and teeth with class IV cavities (C4). Porcelain laminate veneers were made using IPS-Empress ceramic and bonded with Panavia F2 resin cement. The microleakage of all of the specimens was tested before and after cyclic loading (1 × 106 cycles, 1.2 Hz). The fracture resistance values (N) were measured using a universal testing machine, and the mode of failure was also examined. The statistical analyses were performed using one-way ANOVA and Tukey post hoc tests (α=.05).

RESULTS

There was a significant difference in the mean microleakage of group C4 compared with group NT (P=.013). There was no significant difference in the fracture loads among the groups.

CONCLUSION

The microleakage and failure loads of porcelain laminate veneers bonded to intact teeth and teeth with standard class III composite fillings were not significantly different.  相似文献   

15.

PURPOSE

To evaluate the effects of surface treatments on shear bond strength (SBS) between microwave and conventionally sintered zirconia core/veneers.

MATERIALS AND METHODS

96 disc shaped Noritake Alliance zirconia specimens were fabricated using YenaDent CAM unit and were divided in 2 groups with respect to microwave or conventional methods (n=48/group). Surface roughness (Ra) evaluation was made with a profilometer on randomly selected microwave (n=10) and conventionally sintered (n=10) cores. Specimens were then assessed into 4 subgroups according to surface treatments applied (n=12/group). Groups for microwave (M) and conventionally (C) sintered core specimens were as follows; MC,CC: untreated (control group), M1,C1:Al2O3 sandblasting, M2,C2:liner, M3,C3:Al2O3 sandblasting followed by liner. Veneer ceramic was fired on zirconia cores and specimens were thermocycled (6000 cycles between 5°-55℃). All specimens were subjected to SBS test using a universal testing machine at 0.5 mm/min, failure were evaluated under an optical microscope. Data were statistically analyzed using Shapiro Wilk, Levene, Post-hoc Tukey HSD and Student''s t tests, Two-Way-Variance-Analysis and One-Way-Variance-Analysis (α=.05).

RESULTS

Conventionally sintered specimens (1.06 ± 0.32 µm) showed rougher surfaces compared to microwave sintered ones (0.76 ± 0.32 µm)(P=.046), however, no correlation was found between SBS and surface roughness (r=-0.109, P=.658). The statistical comparison of the shear bond strengths of C3 and C1 group (P=.015); CC and MC group (P=.004) and C3 and M3 group presented statistically higher (P=.005) values. While adhesive failure was not seen in any of the groups, cohesive and combined patterns were seen in all groups.

CONCLUSION

Based on the results of this in-vitro study, Al2O3- sandblasting followed by liner application on conventionally sintered zirconia cores may be preferred to enhance bond strength.  相似文献   

16.
The lateral condylar movement can be observed through cat scan images. A clinical method based on the muscular disconnection can be done after recording the physiologic arc of closure. The incisal jig and the relined occlusal basis are used to transfer the immediate side shift, the Benett movement the lateral progressive movement and the condylar inclination on a full adjustable DENAR D5A articulator.  相似文献   

17.

PURPOSE

Veneering porcelain might be delaminated from underlying zirconia-based ceramics. The aim of this study was the evaluation of the effect of different surface treatments and type of zirconia (white or colored) on shear bond strength (SBS) of zirconia core and its veneering porcelain.

MATERIALS AND METHODS

Eighty zirconia disks (40 white and 40 colored; 10 mm in diameter and 4 mm thick) were treated with three different mechanical surface conditioning methods (Sandblasting with 110 µm Al2O3 particle, grinding, sandblasting and liner application). One group had received no treatment. These disks were veneered with 3 mm thick and 5 mm diameter Cercon Ceram Kiss porcelain and SBS test was conducted (cross-head speed = 1 mm/min). Two and one way ANOVA, Tukey''s HSD Past hoc, and T-test were selected to analyzed the data (α=0.05).

RESULTS

In this study, the factor of different types of zirconia ceramics (P=.462) had no significant effect on SBS, but the factors of different surface modification techniques (P=.005) and interaction effect (P=.018) had a significant effect on SBS. Within colored zirconia group, there were no significant differences in mean SBS among the four surface treatment subgroups (P=0.183). Within white zirconia group, "Ground group" exhibited a significantly lower SBS value than "as milled" or control (P=0.001) and liner (P=.05) groups.

CONCLUSION

Type of zirconia did not have any effect on bond strength between zirconia core and veneer ceramic. Surface treatment had different effects on the SBS of the different zirconia types and grinding dramatically decreased the SBS of white zirconia-porcelain.  相似文献   

18.
Sagittal condylar guide settings of three semi‐adjustable articulators: WhipMix®, Hanau 158® and Denar Mark II® were compared using registrations of base plate wax, copper wax and self‐curing acrylic resin in two subjects. Four‐way ANOVA showed differences between instruments ( P < 0·0001), materials ( P < 0·0001), registrations ( P < 0·0001), and no difference between operators. Mean differences between materials were 3°and 6° within the range of registration and articulator variability. Denar Mark II® gave the highest values, Hanau 158® the lowest with pantronic values generally lower than articulator settings. Neither acrylic nor copper wax were superior to base plate wax. This and previous studies show low reproducibility and variability between instruments, occlusal records and registration material.  相似文献   

19.

PURPOSE

The aim of this study was to evaluate effect of different surface treatment methods on the bond strength between aged composite-resin core and luting agent.

MATERIALS AND METHODS

Seventy-five resin composites and also seventy-five zirconia ceramic discs were prepared. 60 composite samples were exposed to thermal aging (10,000 cycles, 5 to 55℃) and different surface treatment. All specimens were separated into 5 groups (n=15): 1) Intact specimens 2) Thermal aging-air polishing 3) Thermal aging- Er:YAG laser irradiation 4) Thermal aging- acid etching 5) Thermal-aging. All specimens were bonded to the zirconia discs with resin cement and fixed to universal testing machine and bond strength testing loaded to failure with a crosshead speed of 0.5 mm/min. The fractured surface was classified as adhesive failure, cohesive failure and adhesive-cohesive failure. The bond strength data was statistically compared by the Kruskal-Wallis method complemented by the Bonferroni correction Mann-Whitney U test. The probability level for statistical significance was set at α=.05.

RESULTS

Thermal aging and different surface treatment methods have significant effect on the bond strength between composite-resin cores and luting-agent (P<.05). The mean baseline bond strength values ranged between 7.07 ± 2.11 and 26.05 ± 6.53 N. The highest bond strength of 26.05 ± 6.53 N was obtained with Group 3. Group 5 showed the lowest value of bond strength.

CONCLUSION

Appropriate surface treatment method should be applied to aged composite resin cores or aged-composites restorations should be replaced for the optimal bond strength and the clinical success.  相似文献   

20.

Statement of Problem:

The accuracy and reliability of the methods used for programming the semi-adjustable articulators determine the accuracy in occlusion. The current recommended average settings using the Hanau''s formula commonly used by clinicians is questionable, and thus reassessment is needed. This study was carried out to evaluate and compare the lateral condylar guidance: (1) Using the Hanau''s formula and the computerized jaw tracking device (Kinesiograph). (2) On the right and left sides using both these methods.

Materials and Methods:

A total of 20 completely edentulous patients (14 male and 6 females) within 40–60 years of age were selected. Jaw relation was recorded followed by face bow transfer. Extraoral Gothic arch tracing was recorded; three protrusive records were obtained and condylar guidance was calculated. Lateral condylar guidance was then calculated using Hanau''s formula, followed by the computerized jaw tracking device. A comparative evaluation was done of the obtained values. The same investigator worked with each of the study participants for the purpose of standardization.

Results:

The lateral condylar guidance values obtained using the Hanau''s formula ranged from 14 to 17° while those obtained using the computerized K7 jaw tracking device ranged from 8 to 40°. Bennett angle values, obtained using the jaw tracking device and Hanau''s formula showed statistically significant differences (P < 0.05) using paired t-test (at 95% confidence interval). Bennett angle values of the right and left sides found using the Hanau''s formula were almost similar. Difference in the Bennett angle values of the right and left sides were found using the jaw tracking device. However, this difference was not statistically significant (P > 0.05).

Conclusion:

Based on the results, dentist and dental technicians should consider reassessing the current recommended average settings and use of the Hanau''s formula for programming the semi-adjustable articulators.Key Words: Articulator, condylar guidance, temporomandibular joint  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号