首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
AIMS: Although measurement of maximum flow rate (Qmax) is a standard and straightforward test, it is often difficult to obtain reliable readings. We obtained multiple measurements using a simple home uroflow device which categorizes Qmax into ranges. We hypothesize that the average of a series of relatively coarse measurements of Qmax would be more repeatable and therefore more representative of an individual's voiding function than a single, albeit more precise measurement. METHODS: We studied 22 male volunteers with a wide range of Qmax. They were asked to record flow category (<10 ml/sec; 10-15 ml/sec; 15-20 ml/sec; >20 ml/sec) and voided volume twice daily for 12 days using the home flow device. In addition, a clinic-based flow recording using a spinning-disc uroflowmeter was obtained at both the start and the end of the 12-day period. RESULTS: Good agreement between mean home flow and mean clinic flow was seen with mean (SD) difference of 1.3 (5) ml/sec. The mean for consecutive halves of an individual's home flow data showed excellent agreement (-0.2 (1.3) ml/sec). The two clinic readings showed poorer agreement (2.3 (6.8) ml/sec) than the home readings, and poorer agreement even than between clinic and home flows. CONCLUSIONS: Although simple in design, the home flowmeter actually shows greater accuracy than might be expected when used repeatedly to study the flow rates of men. Simple flow devices such as this could be used in conjunction with voiding diaries to give a more representative picture of patients' day-to-day voiding function.  相似文献   

2.
3.
4.
5.
6.
7.
8.
9.
10.
Manual suturing still remains the best technique for the creation of vascular anastomoses on uremic patients with excellent results, despite being time consuming, difficult to perform with small vessels, and associated with a significant learning curve. We created a full mechanical arteriovenous fistula on a 65‐year‐old uremic patient with a new device already used in cardiac bypass surgery. The fistula was created automatically and rapidly, without the need for temporary occlusion of the artery, reducing the risk of blood clotting. We believe that mechanical devices may be useful to produce precise and fast anastomoses requiring minimal training for the surgeon.  相似文献   

11.
12.
13.
14.
15.
“Turn‐down” rate has been reported to have a significant influence on outcomes, and being turned down for an operation is associated with significant short‐term mortality risk. A study examining the impact of the pandemic on the “turn‐down” rates of acute aortic syndromes in the United Kingdom reported an overall “turn‐down” rate of  7.3% in the early part of the pandemic. This review examines the significance of “turn‐downs” in this setting and scrutinizes the adequacy of reporting this complex variable.  相似文献   

16.
Ventricular Assist Devices (VADs) were developed following the observation that most end-stage heart failure patients only required left heart support for survival. The trend toward left VAD implantation instead of a TAH has actually contributed to the development of nonpulsatile rotational devices. This article intends to evaluate the current and future technology of continuous flow pumps. Various issues pertaining to the long-term effects of continuous blood flow, biocompatibility of axial flow pumps, and the safety and reliability of such devices need to be addressed. Some of the advantages of rotary blood pumps include their small size, ease of implantation, and encouraging low infection rates. Certain issues such as automatic flow control, device components durability, and hemocompatibility remain unresolved. The quest for an ideal device combining optimal efficiency, ease of anatomical fit, and perfect bioacceptance, continues. Rotary blood pumps are not yet a "must."  相似文献   

17.
Interest in intensified hemodialysis (HD) regimens is increasing internationally, as there is growing evidence that they are associated with improved outcomes. Appreciation that conventional hemodialysis (CHD), delivered as 4-hour sessions three times a week, is not providing optimal physiological replacement of renal function has led to the development of intensified dialysis therapies. These include long intermittent hemodialysis typically lasting 6-8 hours and delivered three times a week, short daily hemodialysis, providing more frequent sessions 4-7 days a week lasting 2-3.5 hours, and nocturnal hemodialysis, performed 5-7 days a week for 6-8 hours. Studies evaluating outcomes from these programs have indicated superior results to those achieved with CHD, including favorable modifications of cardiovascular risk factors and improvements in a variety of clinical measures. The objective of this review is to present available evidence supporting the hypothesis that in an attempt to provide a "more normal physiology," intensified HD regimens achieve outcomes superior to those historically achieved with CHD.  相似文献   

18.
19.
It is unknown how responsive the Fracture Risk Assessment (FRAX) tool is to osteoporosis treatment (OTX) or whether it can serve as a target for “goal‐directed” treatment. We studied 11,049 untreated women aged ≥50 years undergoing baseline and follow‐up DXA examinations in Manitoba, Canada. We identified clinical risk factors, intervening OTX based on medication possession ratios (MPR), and incident fractures. FRAX scores for major osteoporotic and hip fractures were computed for each scan using the most current (updated) FRAX inputs. Over 4 years, median FRAX scores showed an increase of 1.1% for major fractures and 0.3% for hip fractures, including women highly adherent to OTX (0.6% and 0.1% increases). Few (2.2%) highly adherent women had a decrease in major fracture probability exceeding 4%, whereas 9.0% had a decrease in hip fracture probability exceeding 1%. Compared with untreated women, OTX was associated with a higher dose‐dependent likelihood of attenuating the expected increase in major fracture risk: adjusted odds ratios (aOR) 2.3 (95% confidence interval [CI] 1.8–2.9) for MPR <0.50; 7.3 (95% CI 5.6–9.6) for MPR 0.50–0.79; and 12.0 (95% CI 9.5–15.2) for MPR ≥0.80. In the 4 years after the second DXA scan, 620 (6%) women had major fractures (152 hip fractures). FRAX scores were strongly predictive of incident major fractures (adjusted hazard ratios [aHR] per SD increase in FRAX 1.8, 95% CI 1.7–1.9) and hip fractures (aHR per SD 4.5, 95% CI 3.7–5.7); however, change in FRAX score was not independently associated with major fracture (p = 0.8) or hip fracture (p = 0.3). In conclusion, FRAX scores slowly increased over time, and this increase was attenuated but not prevented by treatment. Few women had meaningful reductions in FRAX scores, and change in FRAX score did not independently predict incident fracture, suggesting that FRAX with BMD is not responsive enough to be used as a target for goal‐directed treatment. © 2014 American Society for Bone and Mineral Research.  相似文献   

20.
An iatrogenic arrest is a cardiopulmonary arrest induced by a therapeutic effort. Frequently cardiopulmonary arrests during hemodialysis (HD) are iatrogenic. In this article I consider the question of what to do when a cardiopulmonary arrest occurs during HD in a patient with a do not resuscitate (DNR) order. I consider and reject four arguments to override the DNR order: the principle of nonmaleficence, the efficacy of resuscitation, proximate cause, and physician error. Instead, I argue that respect for patient autonomy and patient goals means that DNR orders must be respected unless there is compelling evidence that overriding the DNR would be consistent with the patient's goals. If such evidence is lacking, the physician has no moral choice but to follow the DNR order literally. As such, nephrologists need better communication with their patients regarding advance care planning and better documentation of their communication once it has occurred.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号