首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Yersinia pestis is a biological agent of high risk to national security due to its ability to be easily disseminated and transmitted among humans. If Y. pestis was to be utilized in a deliberate disease outbreak it would be essential to rapidly and accurately identify the agent. Current identification methods for Yersinia species are limited by their reliance on cultivation, the time taken to achieve results and/or the use of protocols that are not amenable for field use. Faster identification methods are urgently required. Microfluidic capillary electrophoresis was used to identify seven Yersinia species based on their protein profiles. Further objectives included determining if Yersinia species could be detected in mixtures of milk products and Escherichia coli, determining if Yersinia could be detected in a blinded identification and reproducibility across two platforms. Two characteristic protein bands were detected at 50 kilodaltons (kDa) and between 50 and 75 kDa for the Yersinia species. Individual Yersinia species could be differentiated from one another and distinguished from E. coli, Bacillus anthracis Sterne strain and Dipel (containing Bacillus thuringiensis). Due to the high protein content of milk products Yersinia could not be detected when mixed with these but was detected when mixed with E. coli. Species were correctly identified with 96% success in blinded procedures using 12 individuals. Whilst protein profile patterns were reproducible across platforms there was some discrepancy in protein sizing. This study demonstrates that protein profiling using microfluidic capillary electrophoresis is able to rapidly and reproducibly identify and characterize Yersinia species. Results show this technique is a powerful front-line, rapid and broad range screening method capable of identifying and differentiating biological agents, hoax agents and environmental bacterial species.  相似文献   

2.

Objective

Evaluation of the diagnostic efficacy and interobserver agreement of Q-elastography in the differentiation of benign from malignant thyroid nodules.

Methods

A total of 344 thyroid nodules in 288 patients were examined with grey-scale and colour Doppler ultrasound (CDUS) and Q-elastography by two independent operators. Nodules with hypoechogenicity, poorly defined margins, microcalcifications, and intralesional vascularity were classified as suspicious. Diagnostic performances of CDUS features and Q-elastography for predicting thyroid malignancy were estimated using ROC analysis. Cytology or histopathology was the reference standard. Interobserver agreement in the evaluation of CDUS and Q-elastography was assessed using Cohen's k-statistic.

Results

Q-elastography showed excellent diagnostic performance for the prediction of thyroid malignancy, with sensitivity of 93 % and specificity of 92 % for operator 1 (best cutoff at 2.02), and sensitivity of 84 % and specificity of 79 % for operator 2 (best cutoff at 1.86). Performance of Q-elastography was superior to that of CDUS. Reproducibility of the findings was excellent for both Q-elastography and CDUS features as assessed with Cohen's k, which was highest for strain ratio measurements (0.95) and lowest for the echogenicity score (0.83).

Conclusions

Q-elastography showed excellent performance. It is a valid and reproducible diagnostic method as well as a promising tool for identifying suspicious solid thyroid nodules needing cytological assessment and surgery.

Key Points

? Elastography is an additional tool for optimal characterisation of malignant thyroid nodules. ? The use of semiquantitative elastographic evaluation increases the diagnostic performance, ? The interobserver agreement of quantitative elastography can be considered to be good.  相似文献   

3.

Objectives

To evaluate whether readout-segmented echo-planar imaging (RS-EPI) diffusion weighted image (DWI) can diminish image distortion in the head and neck area, compared with single-shot (SS)-EPI DWI.

Methods

We conducted phantom and patient studies using 3 T magnetic resonance imaging (MRI) with a 16-channel coil. For the phantom study, we evaluated distortion and signal homogeneity in gel phantoms. For the patient study, 29 consecutive patients with clinically suspicious parotid lesions were prospectively enrolled. RS-EPI and SS-EPI DWI were evaluated by two independent readers for identification of organ/lesion and distortion, using semiquantitative scales and quantitative scores. Apparent diffusion coefficient (ADC) values and contrast-noise ratios of parotid tumours (if present; n?=?15) were also compared.

Results

The phantom experiments showed that RS-EPI provided less distorted and more homogeneous ADC maps than SS-EPI. In the patient study, RS-EPI was found to provide significantly less distortion in almost all organs/lesions (p?Conclusions The distortion in DWI was significantly reduced with RS-EPI in both phantom and patient studies. The RS-EPI technique provided more homogenous images than SS-EPI, and can potentially offer higher image quality in the head and neck area.

Key Points

? The distortion in DWI is significantly reduced with RS-EPI compared with SS-EPI. ? Structures in the head and neck were identified more clearly using RS-EPI. ? No significant difference in ADC values was found between the techniques.  相似文献   

4.

Objectives

To evaluate the Prostate Imaging Reporting and Data System (PI-RADS) proposed by the European Society of Urogenital Radiology (ESUR) for detection of prostate cancer (PCa) by multiparametric magnetic resonance imaging (mpMRI) in a consecutive cohort of patients with magnetic resonance/transrectal ultrasound (MR/TRUS) fusion-guided biopsy.

Methods

Suspicious lesions on mpMRI at 3.0 T were scored according to the PI-RADS system before MR/TRUS fusion-guided biopsy and correlated to histopathology results. Statistical correlation was obtained by a Mann–Whitney U test. Receiver operating characteristics (ROC) and optimal thresholds were calculated.

Results

In 64 patients, 128/445 positive biopsy cores were obtained out of 95 suspicious regions of interest (ROIs). PCa was present in 27/64 (42 %) of the patients. ROC results for the aggregated PI-RADS scores exhibited higher areas under the curve compared to those of the Likert score. Sensitivity/specificity for the following thresholds were calculated: 73 %/92 % and 85 %/67 % for PI-RADS scores of 9 and 10, respectively; 85 %/56 % and 60 %/97 % for Likert scores of 3 and 4, respectively.

Conclusions

The standardised ESUR PI-RADS system is beneficial to indicate the likelihood of PCa of suspicious lesions on mpMRI. It is also valuable to identify locations to be targeted with biopsy. The aggregated PI-RADS score achieved better results compared to the single five-point Likert score.

Key points

? The ESUR PI-RADS scoring system was evaluated using multiparametric 3.0-T MRI. ? To investigate suspicious findings, transperineal MR/TRUS fusion-guided biopsy was used. ? PI-RADS can guide biopsy locations and improve detection of clinically significant cancer. ? Biopsy procedures can be optimised, reducing unnecessary negative biopsies for patients. ? The PI-RADS scoring system may contribute to more effective prostate MRI.  相似文献   

5.

Objectives

To determine whether positive oral contrast agents improve accuracy of abdominopelvic CT compared with no, neutral or negative oral contrast agent.

Methods

Literature was searched for studies evaluating the diagnostic performance of abdominopelvic CT with positive oral contrast agents against imaging with no, neutral or negative oral contrast agent. Meta-analysis reviewed studies correlating CT findings of blunt abdominal injury with positive and without oral contrast agents against surgical, autopsy or clinical outcome allowing derivation of pooled sensitivity and specificity. Systematic review was performed on studies with common design and reference standard.

Results

Thirty-two studies were divided into two groups. Group 1 comprised 15 studies comparing CT with positive and without oral contrast agents. Meta-analysis of five studies from group 1 provided no difference in sensitivity or specificity between CT with positive or without oral contrast agents. Group 2 comprised 17 studies comparing CT with positive and neutral or negative oral contrast agents. Systematic review of 12 studies from group 2 indicated that neutral or negative oral contrasts were as effective as positive oral contrast agents for bowel visualisation.

Conclusions

There is no difference in accuracy between CT performed with positive oral contrast agents or with no, neutral or negative oral contrast agent.

Key Points

? There is no difference in the accuracy of CT with or without oral contrast agent. ? There is no difference in the accuracy of CT with Gastrografin or water. ?Omission of oral contrast, utilising neutral or negative oral contrast agent saves time, costs and decreases risk of aspiration.  相似文献   

6.
7.

Objectives

To evaluate characteristic features of mammography, ultrasound and magnetic resonance imaging (MRI) of sporadic breast cancer in women <40 years and to determine correlations with pathological and biological factors.

Methods

A retrospective review of radiological, clinicopathological and biological features of sporadic breast cancers for women under 40 years at our institution between 2007-2012 covering 91 patients. Mammography was available for 97 lesions, ultrasound for 94 and MRI for 38.

Results

The most common imaging features were masses, nearly all classified BI-RADS 4 or 5. On mammography microcalcifications alone accounted for 31 %, all suspicious. There were 42.6 % luminal B, 24.5 % luminal A, 19.1 % HER2-enriched and 10.6 % triple-negative (TN) tumours by immunohistochemistry. HER2 overexpression was correlated with the presence of calcifications at mammography (P?=?0.03). TN cancers more often had an oval shape and abrupt interface at ultrasound and rim enhancement on MRI. MRI features were suspicious for all cancers and rim enhancement of a mass was a significant predictor of triple-negative tumours (P?=?0.01).

Conclusions

The imaging characteristics of cancers in patients under 40 years without proven gene mutations do not differ from their older counterparts, but appear correlated to phenotypic profiles, which have a different distribution in young women compared to the general population.

Key Points

? Young women have more luminal B/HER2+ phenotypes than older women. ? The appearance of cancers is correlated with their biological profiles. ? Sporadic breast cancer imaging in young women is generally classified BI-RADS 4/5. ? Triple-negative cancers can be misinterpreted as benign, requiring thorough imaging analysis.  相似文献   

8.

Purpose

The authors analysed the role of diffusion-weighted imaging (DWI) as an additional tool in magnetic resonance (MR) evaluation of prostate cancer.

Materials and methods

Forty-one patients with suspected prostate cancer underwent MR imaging (1.5 Tesla). A DWI sequence was added to the standard morphological protocol, with a maximum b value of 1,000 s/mm2. Diffusion maps were obtained, and the apparent diffusion coefficient (ADC) was calculated by drawing a region of interest (ROI) over healthy tissue and areas suspicious for malignancy. Histology was considered the gold standard.

Results

The areas correctly classified by MR imaging (42/51) had a low signal intensity on T2-weighted imaging and low ADC value (0.99±0.15 mm2/s; p<0.01) compared with the healthy peripheral zone (PZ) (1.73±0.27 mm2/s; p<0.01). Nine areas classified as suspicious for malignancy on T2-weighted sequences showed high ADC (1.44±0.06 mm2/s; p<0.01) and were confirmed to be disease free by subsequent histological examination. The accuracy of morphofunctional MR imaging was 81.6% compared with 73.7% of the morphological analysis alone.

Conclusions

The addition of DWI to the standard protocol increases the overall diagnostic performance of MR imaging in detecting prostatic cancer. Thus, DWI can help the clinician determine the most appropriate management strategy for the patient.  相似文献   

9.

Objectives

To introduce a new three-dimensional (3D) diagnostic imaging technology, termed “multimodal ultrasonic tomography” (MUT), for the detection of breast cancer without ionising radiation or compression.

Methods

MUT performs 3D tomography of the pendulant breast in a water-bath using transmission ultrasound in a fixed-coordinate system. Specialised electronic hardware and signal processing algorithms are used to construct multimodal images for each coronal slice, corresponding to measurements of refractivity and frequency-dependent attenuation and dispersion. In-plane pixel size is 0.25 mm?×?0.25 mm and the inter-slice interval can vary from 1 to 4 mm, depending on clinical requirements. MUT imaging was performed on 25 patients (“off-label” use for research purposes only), presenting lesions with sizes >10 mm. Histopathology of biopsy samples, obtained from all patients, were used to evaluate the MUT outcomes.

Results

All lesions (21 malignant and four benign) were clearly identified on the MUT images and correctly classified into benign and malignant based on their respective multimodal information. Malignant lesions generally exhibited higher values of refractivity and frequency-dependent attenuation and dispersion.

Conclusion

Initial clinical results confirmed the ability of MUT to detect and differentiate all suspicious lesions with sizes >10 mm discernible in mammograms of 25 female patients.

Key Points

? Technical advances in ultrasound offer new diagnostic opportunities in breast imaging ? 3D ultrasound can detect breast cancer without ionising radiation or compression ? Multimodal 3D ultrasound assesses acoustic refractivity, frequency-dependent attenuation and dispersion ? MUT can differentiate between benign and malignant breast lesions  相似文献   

10.

Objective

To assess the feasibility of 7-T contrast-enhanced breast MRI in patients with suspicious masses.

Methods

Twenty patients with 23 suspicious breast masses on conventional imaging (mean size 13 mm, range 5–27 mm) were examined at 7 T. The MRI protocol included a dynamic series with injection of 0.1 mmol/kg gadobutrol (seven consecutive 3D T1-weighted gradient echo sequences, resolution 1?×?1?×?2 mm3, temporal resolution 63 s) and ultra-high-resolution imaging (T1-weighted 3D gradient echo sequence, resolution 0.45?×?0.57?×?0.45 mm3). Two observers (R1 and R2) independently judged the examinations on image quality and classified lesions according to BI-RADS. The added value of ultra-high-resolution imaging was assessed.

Results

The image quality was deemed excellent in 1 and 0, good in 10 and 12, sufficient in 8 and 8, and insufficient in 1 and 0 for R1 and R2 respectively. Twenty of the 23 lesions were identified at 7-T MRI by both observers. All histopathologically proven malignant lesions (n?=?19) were identified and classified as BI-RADS-MRI 4 or 5. Ultra-high-resolution imaging increased reader confidence in 88 % (R1) and 59 % (R2) of acquisitions.

Conclusion

The study shows the feasibility of dynamic contrast-enhanced 7-T breast MRI, where all malignant mass lesions were identified by two observers.

Key Points

? Magnetic resonance imaging is important in the evaluation of breast cancer. ? Recently, 7-T MRI has become available. ? The 7-T dynamic contrast-enhanced breast MRI is feasible in patients. ? The 7-T breast examinations are amenable to evaluation according to BI-RADS.  相似文献   

11.

Objective

We evaluated a functional three-dimensional (3D) infrared imaging system (3DIRI) coupled with multiparametric computer analysis for risk assessment of breast cancer. The technique provides objective risk assessment for the presence of a malignant tumour based on automated parameters derived from a clinically known training set.

Methods

Following institutional review board approval, we recruited 434 women for this prospective multicentre trial, including 256 healthy woman undergoing routine screening mammography with BI-RADS-1 results and 178 women with newly diagnosed breast cancer. This was a two-phase study: an initial training and calibration phase, followed by a two-armed blinded evaluation phase (52 healthy and 66 with breast cancer). 3DIRI data sets were acquired using a non-contact, no radiation system.

Results

The sensitivity and specificity of functional infrared imaging in providing the correct risk for the presence of breast cancer were 90.9 % and 72.5 %, respectively. The area under the ROC curve was 86 %. Forty-two of the 60 (70 %) cancers in women correctly classified by the system as suspicious were smaller than 20 mm in size.

Conclusion

The preliminary blinded results of this novel technology show sufficient performance of functional infrared imaging in providing risk assessment for breast cancer to warrant further clinical studies.

Key Points

? 3D functional infrared imaging (3DIRI) provides new metabolic signatures from breast lesions. ? 3DIRI offers high sensitivity for risk assessment of breast cancer. ? It also has reasonable specificity. ? This initial experience warrants further evaluation in larger clinical trials.  相似文献   

12.

Purpose

The aim of this study was to compare the costeffectiveness of two breast biopsy procedures: surgical biopsy and vacuum-assisted biopsy (VAB).

Materials and methods

Between November 2008 and September 2009, 200 patients with suspicious breast lesions underwent biopsy procedures at our radiology department: 100 underwent VAB and 100 underwent surgical biopsy. 66 lesions were sampled under sonographic guidance, 109 under mammographic guidance and 25 under magnetic resonance guidance.

Results

All procedures were successfully completed. No significant differences in diagnostic efficacy were found between the biopsy procedures. Surgical biopsy has a higher unit cost compared with VAB.

Conclusions

Our analysis emphasises the benefits of VAB compared with surgical biopsy in terms of both costeffectiveness, and less invasiveness from a psychological and aesthetic point of view.  相似文献   

13.

Objective

To assess if the application of diffusion-weighted imaging (DWI) obviates unnecessary MR-guided biopsies in suspicious breast lesions visible only on contrast-enhanced MRI (CE-MRI).

Methods

This institutional review board (IRB)-approved, retrospective, single-centre study included 101 patients (mean age, 49.5; SD 13.9 years) who underwent additional DWI at 1.5 T prior to MRI-guided biopsy of 104 lesions classified as suspicious for malignancy and visible on CE-MRI only. An experienced radiologist, blinded to histopathologic and follow-up results, measured apparent diffusion coefficient (ADC) values obtained from DWI. Diagnostic accuracy was investigated using receiver operating characteristics (ROC) analysis.

Results

Histopathology revealed 20 malignant and 84 benign lesions. Lesions were masses in 61 (15 malignant, 24.6 %) and non-masses in 43 cases (five malignant, 11.6 %). Mean ADC values were 1.53?±?0.38?×?10?3 mm2/s in benign lesions and 1.06?±?0.27?×?10?3 mm2/s in malignant lesions. ROC analysis revealed exclusively benign lesions if ADC values were greater than 1.58?×?10?3 mm2/s. As a consequence, 29 false-positive biopsies (34.5 %) could have been avoided without any false-negative findings. Both in mass and in non-mass lesions, rule-in and rule-out criteria were identified using flexible ADC thresholds based on ROC analysis.

Conclusion

Additional application of DWI in breast lesions visible only on MRI can avoid false-positive, MR-guided biopsies. Thus, DWI should be an integral part of breast MRI protocols.

Key Points

? DWI measurements are a fast and helpful technique for improved breast lesion diagnosis ? DWI application in breast lesions visible only on MRI obviates false-positive, MR-guided biopsies ? Flexible ADC thresholds provide rule-in and rule-out criteria for breast lesion malignancy  相似文献   

14.

Objective

To investigate the diagnostic value of 3-Tesla (T) breast MRI in patients presenting with microcalcifications on mammography.

Methods

Between January 2006 and May 2009, 123 patients with mammographically detected BI-RADS 3–5 microcalcifications underwent 3-T breast MRI before undergoing breast biopsy. All MRIs of the histopathologically confirmed index lesions were reviewed by two breast radiologists. The detection rate of invasive carcinoma and ductal carcinoma in situ (DCIS) was evaluated, as well as the added diagnostic value of MRI over mammography and breast ultrasound.

Results

At pathology, 40/123 (33 %) lesions proved malignant; 28 (70 %) DCIS and 12 (30 %) invasive carcinoma. Both observers detected all invasive malignancies at MRI, as well as 79 % (observer 1) and 86 % (observer 2) of in situ lesions. MRI in addition to conventional imaging led to a significant increase in area under the receiver operating characteristic (ROC) curve from 0.67 (95 % CI 0.56–0.79) to 0.79 (95 % CI 0.70–0.88, observer 1) and to 0.80 (95 % CI 0.71–0.89, observer 2), respectively.

Conclusions

3-T breast MRI was shown to add significant value to conventional imaging in patients presenting with suspicious microcalcifications on mammography.

Key points

? 3-T MRI is increasingly used for breast imaging in clinical practice. ? On 3-T breast MRI up to 86 % of DCIS lesions are detected. ? 3-T MRI increases the diagnostic value in patients with mammographically detected microcalcifications.  相似文献   

15.

Objectives

To compare mammography (MG), contrast-enhanced spectral mammography (CESM), and magnetic resonance imaging (MRI) in the detection and size estimation of histologically proven breast cancers using postoperative histology as the gold standard.

Methods

After ethical approval, 80 women with newly diagnosed breast cancer underwent MG, CESM, and MRI examinations. CESM was reviewed by an independent experienced radiologist, and the maximum dimension of suspicious lesions was measured. For MG and MRI, routine clinical reports of breast specialists, with judgment based on the BI-RADS lexicon, were used. Results of each imaging technique were correlated to define the index cancer. Fifty-nine cases could be compared to postoperative histology for size estimation.

Results

Breast cancer was visible in 66/80 MG, 80/80 CESM, and 77/79 MRI examinations. Average lesion largest dimension was 27.31 mm (SD 22.18) in MG, 31.62 mm (SD 24.41) in CESM, and 27.72 mm (SD 21.51) in MRI versus 32.51 mm (SD 29.03) in postoperative histology. No significant difference was found between lesion size measurement on MRI and CESM compared with histopathology.

Conclusion

Our initial results show a better sensitivity of CESM and MRI in breast cancer detection than MG and a good correlation with postoperative histology in size assessment.

Key points

? Contrast-enhanced spectral mammography (CESM) is slowly being introduced into clinical practice. ? Access to breast MRI is limited by availability and lack of reimbursement. ? Initial results show a better sensitivity of CESM and MRI than conventional mammography. ? CESM showed a good correlation with postoperative histology in size assessment. ? Contrast-enhanced spectral mammography offers promise, seemingly providing information comparable to MRI.  相似文献   

16.

Objectives

Core biopsy underestimates invasion in more than 20% of patients with preoperatively diagnosed ductal carcinoma in situ (DCIS) without evidence of invasion (pure DCIS). The aim of the current study was to evaluate the efficacy of preoperative magnetic resonance imaging (MRI) to discriminate between patients with DCIS who are at high risk of invasive breast cancer and patients at low risk.

Methods

One hundred and twenty-five patients, preoperatively diagnosed with pure DCIS (128 lesions; 3 bilateral) by core-needle biopsy, were prospectively included. Clinical, mammographic, histological (core biopsy) and MRI features were assessed. All patients underwent breast surgery. Analyses were performed to identify features associated with presence of invasion.

Results

Eighteen lesions (14.1%) showed invasion on final histology. Seventy-three lesions (57%) showed suspicious enhancement on MRI with a type 1 (n?=?12, 16.4%), type 2 (n?=?19, 26.0%) or type 3 curve, respectively (n?=?42, 57.5%). At multivariate analysis, the most predictive features for excluding presence of invasive disease were absence of enhancement or a type 1 curve on MRI (negative predictive value 98.5%; AZ 0.80, P?=?0.00006).

Conclusion

Contrast medium uptake kinetics at MRI provide high negative predictive value to exclude presence of invasion and may be useful in primary surgical planning in patients with a preoperative diagnosis of pure DCIS.

Key Points

? It is important to determine invasion in breast DCIS. ? MRI contrast medium uptake kinetics can help exclude the presence of invasion. ? However, the positive predictive value for the presence of invasion is limited. ? MRI features were more accurate at predicting invasion than mammographic features alone.  相似文献   

17.
18.

Objective

To prove that DNA damage, intracellular reactive oxygen species (ROS) generation and loss of mitochondrial membrane potential (MMP) are contributing factors for the inhibition of cell proliferation induced by doxorubicin (DOX) administration combined with microbubble-assisted low-level therapeutic ultrasound (US) in K562 cells.

Methods

3-(4, 5-dimethylthiazol-2-yl)-2, 5-diphenyl tetrazolium bromide assay was adopted to examine cytotoxicity of different treatments. Changes on apoptosis and necrosis rates, DNA fragmentation, intracellular reactive oxygen species production, mitochondrial membrane potential, cellular membrane permeability and DOX-uptake were analysed by flow cytometry. Nuclear morphology changes were observed under a fluorescence microscope. Ultrasonic cavitation was measured by spectrofluorimetry.

Results

Under optimal conditions, MB-US significantly aggravated DOX-induced K562 cell death, especially necrosis, when compared with either monotherapy. Synergistic potentiation on DNA damage, ROS generation and MMP loss were observed. Ultrasonic cavitation effects, plasma membrane permeabilization and DOX-uptake were notably improved after MB-US exposure.

Conclusions

MB-US could increase the susceptibility of tumours to antineoplastic drugs, suggesting a potential clinical method for US-mediated tumour chemotherapy.

Key Points

? Microbubble-ultrasound (MB-US) aggravated doxorubicin (DOX) induced K562 cell death, especially necrosis ? MB-US synergistically potentiated DOX-initiated DNA damage, ROS generation and MMP loss ? Ultrasonic cavitation effects, plasma membrane permeabilization and DOX-uptake were improved after treatment ? MB-US holds significant potential for improving the efficacy of conventional chemotherapy  相似文献   

19.

Objective

To evaluate the diagnostic accuracy of positron emission mammography (PEM) for identifying malignant lesions in patients with suspicious microcalcifications detected on mammography.

Methods

A prospective, single-centre study that evaluated 40 patients with suspicious calcifications at mammography and indication for percutaneous or surgical biopsy, with mean age of 56.4 years (range: 28-81 years). Patients who agreed to participate in the study underwent PEM with 18F-fluorodeoxyglucose before the final histological evaluation. PEM findings were compared with mammography and histological findings.

Results

Most calcifications (n?=?34; 85.0 %) were classified as BIRADS 4. On histology, there were 25 (62.5 %) benign and 15 (37.5 %) malignant lesions, including 11 (27.5 %) ductal carcinoma in situ (DCIS) and 4 (10 %) invasive carcinomas. On subjective analysis, PEM was positive in 15 cases (37.5 %) and most of these cases (n?=?14; 93.3 %) were confirmed as malignant on histology. There was one false-positive result, which corresponded to a fibroadenoma, and one false negative, which corresponded to an intermediate-grade DCIS. PEM had a sensitivity of 93.3 %, specificity of 96.0 % and accuracy of 95 %.

Conclusion

PEM was able to identify all invasive carcinomas and high-grade DCIS (nuclear grade 3) in the presented sample, suggesting that this method may be useful for further evaluation of patients with suspected microcalcifications.

Key Points

? Many patients with suspicious microcalcifications at mammography have benign results at biopsy. ? PEM may help to identify invasive carcinomas and high-grade DCIS. ? Management of patients with suspicious calcifications can be improved.
  相似文献   

20.

Objectives

Breastfeeding is a well-recognised investment in the health of the mother-infant dyad. Nevertheless, many professionals still advise breastfeeding mothers to temporarily discontinue breastfeeding after contrast media imaging. Therefore, we performed this review to provide health professionals with basic knowledge and skills for appropriate use of contrast media.

Methods

A joint working group of the Italian Society of Radiology (SIRM), Italian Society of Paediatrics (SIP), Italian Society of Neonatology (SIN) and Task Force on Breastfeeding, Ministry of Health, Italy prepared a review of the relevant medical literature on the safety profile of contrast media for the nursing infant/child.

Results

Breastfeeding is safe for the nursing infant of any post-conceptional age after administration of the majority of radiological contrast media to the mother; only gadolinium-based agents considered at high risk of nephrogenic systemic fibrosis (gadopentetate dimeglumine, gadodiamide, gadoversetamide) should be avoided in the breastfeeding woman as a precaution; there is no need to temporarily discontinue breastfeeding or to express and discard breast milk following the administration of contrast media assessed as compatible with breastfeeding.

Conclusions

Breastfeeding women should receive unambiguous professional advice and clear encouragement to continue breastfeeding after imaging with the compatible contrast media.

Key Points:

? Breastfeeding is a well-known investment in the health of the mother-infant dyad. ? Breastfeeding is safe after administration of contrast media to the mother. ? There is no need to temporarily discontinue breastfeeding following administration of contrast media.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号