首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
An assay based on automated liquid-liquid extraction (LLE) and liquid chromatography-tandem mass spectrometry (LC/MS/MS) has been developed and validated for the quantitative analysis of simvastatin (SV) and its beta-hydroxy acid (SVA) in human plasma. A Packard MultiProbe II workstation was used to convert human plasma samples collected following administration of simvastatin and quality control (QC) samples from individual tubes into 96-well plate format. The workstation was also used to prepare calibration standards and spike internal standards. A Tomtec Quadra 96-channel liquid handling workstation was used to perform LLE based on 96-well plates including adding solvents, separating organic from aqueous layer and reconstitution. SV and SVA were separated through a Kromasil C18 column (50 mm x 2 mm i.d., 5 microm) and detected by tandem mass spectrometry with a TurboIonspray interface. Stable isotope-labeled SV and SVA, 13CD(3)-SV and 13 CD(3)-SVA, were used as the internal standards for SV and SVA, respectively. The automated procedures reduced the overall analytical time (96 samples) to 1/3 of that of manual LLE. Most importantly, an analyst spent only a fraction of time on the 96-well LLE. A limit of quantitation of 50 pg/ml was achieved for both SV and SVA. The interconversion between SV and SVA during the 96-well LLE was found to be negligible. The assay showed very good reproducibility, with intra- and inter-assay precision (%R.S.D.) of less than 7.5%, and accuracy of 98.7-102.3% of nominal values for both analytes. By using this method, sample throughput should be enhanced at least three-fold compared to that of the manual procedure.  相似文献   

2.
A high-throughput bioanalytical method using automated sample transferring, automated liquid-liquid back extraction and liquid chromatography-tandem mass spectrometry was developed in a GLP regulated environment for the determination of ABT-202 in human plasma. Samples of 0.30 ml were transferred into 96-well plate using an automatic liquid handler. Automated liquid-liquid extraction (LLE) was carried out on a 96-channel programmable liquid handling workstation using methyl tert-butyl ether as the extraction solvent. A dual-HPLC with single mass spectrometer configuration was utilized to provide a reliable and routine means to increase sample throughput. The standard curve range was 0.38-95.02 ng/ml. There was no interference from endogenous components in the blank plasma tested. The accuracy (% bias) at the lower limit of quantitation (LLOQ) was 7.7% and the precision (% CV) for samples at the LLOQ was 4.7%. The inter-day % CV and % bias of the quality control samples were < or = 6.8 and < or = 7.6%, respectively. Coefficients of determination, a measure of linearity, ranged from 0.994 to 0.997. The method was accurate and reproducible and was successfully applied to generate plasma concentration-time profiles for human subjects after low oral doses of the compound.  相似文献   

3.
A single-pot liquid-liquid extraction (LLE) with hydrophilic interaction liquid chromatography/tandem mass spectrometry (HILIC/MS/MS) method has been developed and validated for the determination of muraglitazar, a hydrophobic diabetes drug, in human plasma. To 0.050 ml of each plasma sample in a 96-well plate, the internal standard solution in acetonitrile and toluene were added to extract the compound of interest. The plate was vortexed, followed by centrifugation. The organic layer was then directly injected into an LC/MS/MS system. Chromatographic separation was achieved isocratically on a Thermohypersil_Keystone, Hypersil silica column (3 mmx50 mm, 3 microm). The mobile phase contained 85% of methyl t-butyl ether and 15% of 90/10 (v/v) acetonitrile/water with 0.3% trifluoroacetic acid. Post-column mobile phase of 50/50 (v/v) acetonitrile/water containing 0.1% formic acid was added. Detection was by positive ion electrospray tandem mass spectrometry on a Sciex API 4000. The standard curve, ranged from 1 to 1000 ng/ml, was fitted to a 1/x weighted quadratic regression model. This single-pot LLE approach effectively eliminated time-consuming organic layer transfer, dry-down, and sample reconstitution steps, which are essential for a conventional liquid-liquid extraction procedure. The modified mobile phase was more compatible with the direct injection of the commonly used extraction solvents in LLE. Furthermore, the modified mobile phase improved the retention of muraglitazar, a hydrophobic compound, on the normal phase silica column. The validation results demonstrated that this method was rugged and suitable for analyzing muraglitazar in human plasma. In comparison with a revised-phase LC/MS/MS method, this single-pot LLE, HILIC/MS/MS method improved the detection sensitivity by more than four-fold based upon the LLOQ signal to noise ratio. This approach may be applied to other hydrophobic compounds with proper modification of the mobile phase compositions.  相似文献   

4.
A rapid, sensitive and selective hydrophilic interaction liquid chromatography-tandem mass spectrometric (HILIC-MS/MS) method for the determination of tiapride in human plasma was developed. Tiapride and internal standard, metoclopramide were extracted from human plasma with dichloromethane at basic pH and analyzed on an Atlantis HILIC silica column with the mobile phase of acetonitrile-ammonium formate (190 mM, pH 3.0) (94:6, v/v). The analytes were detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.999) over the concentration range of 1.00-200 ng/mL. The coefficient of variation and relative error for intra- and interassay at three QC levels were 6.4-8.8% and -2.0-3.6%, respectively. The recoveries of tiapride ranged from 96.3 to 97.4%, with that of metoclopramide (internal standard) being 94.2%. The lower limit of quantification for tiapride was 1.00 ng/mL using 100 microL of plasma sample.  相似文献   

5.
A bioanalytical method using automated sample transferring, automated solid phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed for morphine (MOR), and its metabolites morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G) in human plasma. Samples of 0.25 ml were transferred into 96-well plate using automatic liquid handler (Multiprobe II). Automated SPE was carried out on a 96-channel programmable liquid handling workstation (Quadra 96) using a C(18) sorbent. The extract was injected onto a silica column using an aqueous-organic mobile phase. The chromatographic run time was 3.5 min per injection, with retention times of 1.5, 2.0 and 2.6 min for MOR, M6G, and M3G, respectively. The detection was by monitoring MOR at m/z 286-->152, M6G and M3G at m/z 462-->286. The deuterated internal standards were monitored at m/z 289-->152 for MOR-d(3), and m/z 465-->289 for M6G-d(3) and M3G-d(3). The standard curve range was 0.5-50 ng ml(-1) for MOR, 1.0-100 ng ml(-1) for M6G, and 10-1000 ng ml(-1) for M3G. The inter-day precision and accuracy of the quality control samples were <8% relative standard deviation (RSD) and <7% relative error (RE) for MOR, <5% RSD and <2% RE for M6G, and <2% RSD and <4% RE for M3G.  相似文献   

6.
Phase II attrition of clinical candidates in the drug development cycle is currently a major issue facing the pharmaceutical industry. To decrease phase II attrition, there is an increased emphasis on validation of mechanism of action, development of efficacy models and measurement of drug levels at the site of action. PD 0332991, a highly specific inhibitor of cyclin-dependent kinase 4 (CDK-4) is currently in clinical development for the treatment of solid tumor. A clinical presurgical study will be required to better understand how PD 0332991 affects signaling pathways and how the intratumoral concentration of PD 0332991 correlates with plasma PK parameters and molecular alterations in breast cancer tissues after PD 0332991 treatment. Before conducting such a clinical study, it is important to evaluate PD 0332991 levels in tumor tissue samples from a xenograft mouse model for the determination of drug exposure at the site of action. Therefore, the objectives of this study were (1) to develop and validate a sensitive LC–MS/MS method to quantify PD 0332991 in mouse tumor tissues from MDA-MB-231-Luc human breast tumor xenografts in SCID-beige mice; (2) to quantify PD 0332991 levels in mouse tumor tissues after oral administration of PD 0332991 at 10 and 100 mg/kg using the validated LC–MS/MS method. Both liquid–liquid extraction (LLE) and supported liquid extraction (SLE) in a 96-well format were developed and evaluated to achieve optimal extraction recovery with minimal matrix effects. The newly developed SLE method is more efficient (speed and ease) and demonstrates comparable recovery (93.1–100% at three different concentrations) compared to the traditional LLE method. The validated LC–MS/MS for PD 032291 in mouse tumor tissue homogenate method exhibited a linear dynamic range of 0.1–100 ng/mL with inter-day accuracy and precision within 15%. The validated method was successfully applied to measure PD 0332991 levels in tumor tissues in MDA-MB-231-Luc human breast tumor xenografts in SCID beige mice. The mean tumor concentrations at 6 h post-oral PD 0332991 administration at 10 and 100 mg/kg were 1793 (±1008) and 25,163 (±3959) ng/g, respectively.  相似文献   

7.
A rapid, sensitive and selective method for the determination of carvedilol in human plasma was developed using hydrophilic interaction liquid chromatography with tandem mass spectrometry (HILIC-MS/MS). Carvedilol and cisapride (internal standard) were extracted from human plasma with methyl tert-butyl ether at basic pH and analyzed on an Atlantis HILIC Silica column with the mobile phase of acetonitrile-ammonium formate (50 mM, pH 4.5) (90:10, v/v). The analytes were detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r=0.9998) over the concentration range of 0.1-200 ng/ml. The lower limit of quantification for carvedilol was 0.1 ng/ml using 50 microl plasma sample. The coefficient of variation and relative error for intra- and inter-assay at four QC levels were 1.6-4.5% and -6.4 to 4.8%, respectively. The absolute and relative matrix effect for carvedilol and cisapride were practically absent. The extraction recoveries of carvedilol and cisapride were 81.6 and 85.2%, respectively. This method was successfully applied to the bioequivalence study of carvedilol in humans.  相似文献   

8.
A sensitive liquid chromatography-tandem mass spectrometry (LC/MS/MS) method was developed and validated for the determination of trimetazidine (CAS 13171-25-0) in human plasma, using pseudoephedrine as internal standard (IS). Plasma samples were simply pretreated with methanol for deproteinization. The chromatographic separation was performed on a C18 column with a mobile phase of 3 mmol/L ammonium acetate solution-methanol (15:85, v/v) at a flow rate of 0.3 mL/min. The chromatographic separation was achieved in less than 3.2 min. The linearity was established over the concentration range of 1-100 ng/mL. Both intra- and inter-batch standard deviations were less than 9.5%. The method was successfully applied to study the relative bioavailability of trimetazidine hydrochloride tablets in healthy Chinese volunteers and the pharmacokinetic parameters of the reference and test tablets were compared.  相似文献   

9.
A simple, rapid and sensitive liquid chromatography-tandem mass spectrometry method was developed for quantification of deglymidodrine in human plasma. The plasma samples were pretreated by protein precipitation with trichloroacetate. The chromatographic separation was performed on reversed phase Aquasil C18 column, and the plasma extraction was eluted with a mobile phase solution consisting of acetonitrile (containing 0.02% formic acid) and water (containing 0.02% formic acid). The molecular ion of analyte was detected in positive ionization by multiple reaction monitoring. The mass transitions of m/z 198.4--> 148.1 and m/z 212.4--> 162.3 were used for detection of deglymidodrine and its internal standard, respectively. The assay exhibited linear ranges from 0.25 to 32 ng/ml for the analyte in human plasma. Acceptable precision and accuracy were obtained for concentrations of quality control (QC) samples. The proposed method has been successfully used to analyze human plasma samples for application in oral pharmacokinetic study.  相似文献   

10.
A rapid, sensitive and selective hydrophilic interaction liquid chromatography-tandem mass spectrometric (HILIC-MS/MS) method for the determination of levofloxacin in human plasma was developed. Levofloxacin and ciprofloxacin (internal standard) were extracted from human plasma with dichloromethane and analyzed on an Atlantis HILIC Silica column with the mobile phase of acetonitrile-ammonium formate (100 mM, pH 6.5) (82:18 v/v). The analytes were detected using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. The standard curve was linear (r>0.999) over the concentration range of 10.0-5000 ng/ml. The lower limit of quantification for levofloxacin was 10.0 ng/ml using 20 microl plasma sample. The coefficient of variation and relative error for intra- and inter-assay at four QC levels were 2.9-7.8% and -7.3% to -2.2%, respectively. The recoveries of levofloxacin and ciprofloxacin were 55.2% and 77.3%, respectively. This method was successfully applied to the pharmacokinetic study of levofloxacin in humans.  相似文献   

11.
A fast and selective ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for the determination of amphetamines (amphetamine, methamphetamine, methylenedioxymethamphetamine, methylenedioxyamphetamine, methylenedioxyethylamphetamine, ephedrine, and p-methoxyamphetamine) in plasma has been developed and validated. Sample preparation was performed by liquid-liquid extraction using ethyl acetate. For optimized chromatographic performance with repeatable retention times, narrow and symmetrical peaks, and focusing all analytes at the column inlet, a gradient start, with acid mobile phase consisting of 0.1% formic acid and methanol was chosen. Positive electrospray ionization MS-MS detection was performed with two multiple reaction monitoring transitions for each analyte. Deuteriumlabeled internal standards were used for five of the analytes. The limit of detection was in the range 0.25-1.25 ng/mL, and the limit of quantification was fixed at the lowest calibrator of 2.5 ng/mL for all of the compounds. The RSD values of the intra- and interassay precision and accuracy were lower than 11% at four concentration levels, including two external quality controls. No or only minor matrix effects were observed, and the extraction method presented recoveries higher than 93% for all the compounds. Total run time, including equilibration, was 12 min. The method is routinely used at the National Institute of Criminalistics and Criminology for quantitative determination of the main amphetamines in plasma from forensic and driving under the influence cases.  相似文献   

12.
This paper describes a high-throughput sample preparation procedure combined with LC-MS/MS analysis to measure paclitaxel in human plasma. Paclitaxel and an internal standard were extracted from plasma by a semi-automated robotic method using liquid-liquid extraction. Thereafter compounds were separated on a RP C18 column. Detection was by a PE Sciex API 3000 mass spectrometer equipped with a TurboIonSpray interface. The compounds were detected in positive ion mode using the mass transition m/z 854.6-->286.2 and m/z 831.6-->263.2 for paclitaxel and the internal standard, respectively. The limit of quantitation for paclitaxel was 1 ng/ml with an imprecision of 5.2% following extraction of 0.1 ml of plasma. Linearity was confirmed over the whole calibration range (1-1000 ng/ml) with correlation coefficients higher than 0.99 indicating good fits of the regression models. The inter and intra-day precision was better than 9.5% and the accuracy ranged from 90.3 to 104.4%. The assay was simple, fast, specific and exhibited excellent ruggedness.  相似文献   

13.
目的 建立人血浆中头孢克肟的LC/MS/MS法.方法 血浆样品经蛋白沉淀提取,采用C8色谱柱分析,以乙腈:水:甲酸(40:60:0.5,v/v/v)为流动相,三重四级杆质谱检测器,正离子多反应监测模式(MRM),监测离子分别为:m/z 454.3→m/z 285.2(头孢克肟),m/z 282.2→m/z 212.2(...  相似文献   

14.
With the objective of reducing analysis time and maintaining good efficiency, there has been substantial focus on high-speed chromatographic separations and ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) is a preeminent analytical tool for rapid biomedical analysis. In this study a simple, rapid, sensitive, and specific ultra-performance liquid chromatography-MS/MS method was developed and validated for quantification of the angiotensin II receptor antagonist, irbesartan (IRB), in human plasma. After a simple protein precipitation using methanol and acetonitrile, IRB and internal standard (IS) telmisartan were separated on Acquity UPLC BEH C18 column (50 mm × 2.1 mm, i.d. 1.7 μm, Waters, Milford, MA, USA) using a mobile phase consisted of acetonitrile: methanol: 10 mM ammonium acetate (70: 15: 15 v/v/v) with a flow rate of 0.4 mL/min and detected MS/MS in negative ion mode. The ion transitions recorded in multiple reaction monitoring mode were m/z 427.2→193.08 for IRB and m/z 513.2→469.3 for IS. The assay exhibited a linear dynamic range of 2–500 ng/mL for IRB in human plasma with good correlation coefficient of (0.995) and with a lower limit of quantitation of 2 ng/mL. The intra- and interassay precisions were satisfactory; the relative standard deviations did not exceed 9.91%. The proposed UPLC-MS/MS method is simple, rapid, and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans.  相似文献   

15.
Two sensitive and selective methods based on solid phase microextraction (SPME) and liquid-liquid extraction (LLE) in 96-well format, in combination with high performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection have been developed to determine a model drug compound in human plasma. Both assays were performed on an Applied Biosystems-Sciex API 4000 tandem mass spectrometer interfaced with a turbo ion-spray probe and operated in the negative ionization mode. A lower limit of quantitation (LLOQ) of 1 ng/mL achieved when 0.25 mL of human plasma was processed. In both methods, a stable isotope labeled internal standard was utilized. The methods were validated in the concentration range of 1-500 ng/mL. The intraday precision (%C.V.) of the method using LLE was 0.8% at LLOQ, and was equal to or lower than 3.3% at all other concentrations, while the intraday precision (%C.V.) of the method using SPME was 6.9% at LLOQ, and was equal to or lower than 5.7% at all other concentrations. Based on the direct comparison of the two methods and their successful applications in clinical sample analysis, it may be concluded that SPME may be considered and used as an alternative approach for quantitative determination of drugs in pharmacokinetic studies.  相似文献   

16.
PGE9509924, a novel nonfluorinated quinolone, is a potent antibacterial agent with a broad spectrum of activity. A semi-automated method using 96-well format, solid-phase extraction has been developed for quantitating PGE9509924 in rat plasma. The Waters Oasis HLB extraction plate containing a polymeric packing material was found to give the best overall recoveries. All liquid transfer steps other than aliquoting the plasma are accomplished using a 96-channel pipettor. Reverse-phase HPLC with electrospray/MS/MS detection using selective reaction monitoring is used to quantitate the samples. Stable isotopically labeled PGE9509924 is used as the internal standard. The assay is linear over the range from 0.01 to 10 ug/ml. Excellent precision is obtained within a single run and between multiple runs performed on different days. CVs of <6% were observed. The combination of the semi-automated, 96-well parallel sample processing and the short runtime on the LC/MS/MS results in a high throughput assay with reduced operator interaction.  相似文献   

17.
A sensitive, fast, and reproducible high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of diethylstilbestrol in human plasma was developed and validated. The plasma samples were pretreated by direct deproteinization with ethyl acetate. Daidzein was used as the internal standard. The separation was carried out on a Agilent Technologies 1200 series XDB C18 column (2.1 mm×150 mm, 5 µm) with a mobile phase of acetonitrile-2.5 mmol/L ammonium acetate (60:40, v/v). Triple quadrupole mass spectrometric detection in negative ion mode was used for multiple-reaction-monitoring of the transitions atm/z 267.2→237.3 and m/z 253.2→132.3 for diethylstilbestrol and daidzein, respectively.The calibration curves were linear over the concentration range from 0.1 to 20 ng/mL (r2 = 0.9984). The lower limit of quantificationwas 0.1 ng/mL (s/n mLs)for diethylstilbestrol, which was sensitive enough to perform pharmacokinetic studies after diethylstilbestroladministration. Inter-day and intra-day precisions were no more than 7% with accuracies of 90%-105%. This method could be applied to therapeutic drug monitoring of diethylstilbestrol, which is helpful for evaluating the clinical efficacy and safety of diethylstilbestrol.  相似文献   

18.
Deng P  Chen X  Zhong D 《Bioanalysis》2009,1(1):187-203
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has played an important role in quantitative bioanalytical assays. This review summarizes the recent progress on quantification of polar drugs in plasma with LC-MS/MS. Various types of polar analytes were extracted using protein precipitation or solid-phase extraction and precolumn derivatization was utilized in some cases. The analytes were then separated using different types of chromatographic method, which included reversed-phase chromatography, aqueous normal-phase chromatography, hydrophilic interaction liquid chromatography and ion-pairing chromatography. Stationary phases of mixed mode and porous graphitic carbon materials are gaining acceptance in bioanalytical applications. These technologies can be valuable supplements in the quantification of polar drugs in human plasma with LC-MS/MS. Matrix effects have also been discussed in this review.  相似文献   

19.
A fast and sensitive HPLC-MS/MS method, utilizing atmospheric pressure chemical ionization, for the determination of fexofenadine in human plasma is described. A deuterated analog, d6-fexofenadine is used as the internal standard (IS). Plasma samples are prepared using 96-well solid phase extraction with plates containing Waters Oasis HLB sorbent. The analytes are chromatographed on a Restek Ultra IBD column (3.2 mm x 50 mm, 3 microm) using a mobile phase consisting of a mixture of 90% acetonitrile and 10% 10 mM ammonium acetate buffer and 0.1% formic acid. Quantitation of the analyte is based on the response from the multiple reaction monitoring of the precursor to product ion pairs for fexofenadine (m/z 502 --> 466) and d6-fexofenadine (m/z 508 --> 472). The assay has been validated over the concentration range of 1-200 ng/ml based on the analysis of 0.5 ml aliquots of plasma. Within-day assay accuracy was between 97 and 102% of nominal, while within-day precision was better than 3.5% CV at all points on the standard curve. Analyte extraction recovery was better than 70% over the range of the standard curve. The method was found to be suitable for the analysis of human plasma samples obtained 24 h following the administration of a single 60 mg dose of fexofenadine.  相似文献   

20.
The strong polar quaternary ammoniums, acetylcholine (ACh), choline (Ch) and butyrobetaine (BB, (3-carboxypropyl)trimethylammonium), are believed playing important roles in liver metabolism. These metabolites are at low levels and are weakly retained on reversed-phase liquid chromatographic (RP-LC) columns. Several hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) methods have been reported to analyze these compounds from different samples. However, no application to human liver tissues has been published. In this study, HILIC-MS/MS method was developed to simultaneously determine these three metabolites in human liver tissues. They were simply extracted from tissue, separated on a HILIC column, and detected by tandem MS in the mode of multiple reaction monitoring (MRM). Further studies on the recovery and repeatability based on real samples indicated the method was accurate and reliable. This method was successfully applied to measure the levels of ACh, Ch and BB in 61 human liver tissue samples including normal, hepatocellular carcinoma (HCC) and matched non-cancerous liver tissues. By comparison of Ch and ACh contents in 29 HCC with their matched non-cancerous liver tissues, it was found that ACh content increased in 11/29 HCC cases and decreased in 13/29 cases. Furthermore, the ACh/Ch ratio increased in 16/29 HCC cases, while it decreased in 8/29 cases. These results strongly indicated that there exist different patterns of ACh content in cancer tissues among HCC patients, thus highlighting the understanding of ACh and its relevant signal pathways in hepatic carcinogenesis and HCC progression.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号