首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BackgroundHighly cross-linked polyethylene (HXLPE) is the most commonly used bearing surface in total hip arthroplasty (THA) because of its superior wear properties, but long-term results in young patients are limited. Mid-term survivorship has been promising; however, polyethylene wear rates and need for revision surgeries remain a concern in this population. The purpose of our study is to investigate polyethylene wear rates, implant survivorship, wear-related revisions, and patient-reported outcomes in a young patient cohort at 15-year follow-up.MethodsWe performed a retrospective study of a prospective longitudinal cohort of 82 consecutive patients (89 hips) who underwent primary THA with an HXLPE acetabular liner and a cobalt-chromium femoral head. The mean age at the time of surgery for the cohort was 38.8 years (range 12-50). All patients received HXLPE liners with a cementless acetabular component coupled with a cobalt-chrome femoral head through a posterior approach with a cementless femoral component. All components were from a single manufacturer. We recorded University of California, Los Angeles Activity, and modified Harris Hip Scores. Wear calculations were made using the Martell Hip Analysis Suite (Version 8.0.4.3).ResultsAt average 15 years (range 13.1-18.5), there was a revision-free survivorship of 97.8% in our HXLPE group with no wear-related revisions. We observed a linear wear rate of 0.0185 mm/y (standard deviation 0.05) after accounting for a 1-year bedding-in period. The volumetric wear rate was found to be 12.80 mm3/y (standard deviation 22.69). These numbers are registered as clinically undetectable and are comparable to steady state wear rates in the same cohort of patients at earlier time points. We found no radiographic changes concerning osteolysis. We observed excellent patient-reported outcomes at this time point with improvements in modified Harris Hip Scores (35.3 [22.5], P < .0001) and University of California, Los Angeles Activity Scores (median 6.0, P < .0001).ConclusionAt 15-year follow-up, we demonstrated that HXLPE bearings in this young cohort had excellent wear properties, maintained superior clinical improvements, and underwent no wear-related revision operations. The HXLPE and cobalt-chrome bearing couple continues to be extremely effective 15 years after primary THA in patients less than 50 years.Level of EvidenceIV.  相似文献   

2.

Background

A number of studies on total hip arthroplasty have compared highly cross-linked polyethylene (HXLPE) with conventional polyethylene (CPE) liners beyond 10 years. However, the impact of HXLPE on the wear-related reoperation rate is unclear. The purpose of this study was to evaluate the clinical advantage of using a single manufacturer's HXLPE in terms of reducing the reoperation rate.

Methods

The study was a follow-up retrospective cohort study over a mean of 12 years that examined patients aged 45-70 years with cementless total hip arthroplasty using a 26-mm-diameter cobalt-chromium head. Sixty-seven patients (79 hips; HXLPE group = 41 hips, CPE group = 38 hips) were evaluated for a minimum 10-year follow-up. Kaplan-Meier survival analysis was performed, with wear-related reoperations and radiographic osteolysis serving as the end points. The polyethylene wear rate was also assessed.

Results

The mean 12-year follow-up rates of survivorship that were evaluated using wear-related reoperations as the end point were 100% and 91.4% in the HXLPE and CPE groups, respectively (P = .007), and the mean 12-year follow-up rates of survivorship with osteolysis as the end point were 100% and 36.2%, respectively (P < .001). Compared with the CPE group, the HXLPE group presented a significantly reduced wear rate (HXLPE group, 0.035 mm/y; CPE group, 0.118 mm/y).

Conclusion

A unique strength of this study is that we assessed a single manufacturer's HXLPE while keeping most other implant parameters uniform. This study reveals the clinical advantage of using a single manufacturer's HXLPE in terms of a reduced wear-related reoperation rate at a mean 12-year follow-up.  相似文献   

3.
《The Journal of arthroplasty》2021,36(9):3226-3232
BackgroundThe average age of patients benefiting from total hip arthroplasty (THA) has been declining. In addition to pain relief, patients seek to return to physical activity. However, the latter may increase polyethylene wear and therefore the potential risk of early aseptic loosening. The introduction of highly crosslinked polyethylene (HXLPE) has reduced wear rates in the general patient population. The objective of this study was to evaluate the influence of impact sports in patients operated with THA using ceramic-on-conventional polyethylene (cPE) versus ceramic-on-HXLPE, in terms of wear and function, with a minimum of five year follow-up.MethodsSixty-eight patients practicing an impact sport (University of California Los Angeles score ≥8) who underwent a primary THA were included: 34 with a ceramic-on-cPE versus 34 with a ceramic-on-HXLPE using the same cementless acetabular and femoral component. Patients were matched-paired by age, sex, BMI, and University of California Los Angeles score. The wear analysis was performed using the IMAGIKA software. The Harris hip score and hip and osteoarthritis outcome score were collected.ResultsThe linear wear rate was statistically higher (P < .0001) in the cPE group (0.13503 ± 0.0630 mm/year) than in the HXLPE group (0.03059 ± 0.0084 mm/year). Postoperatively, the increase in Harris hip score was calculated at 37.64 for the entire cohort and was comparable in both groups (P = .3674). The hip and osteoarthritis outcome score for pain (P = .0009), daily life activities (P = .0016), and quality of life (P = .0179) were significantly higher in the HXLPE group, with, between groups, a difference inferior to the reported minimal clinical important difference. Three patients exhibited signs of periprosthetic osteolysis in the cPE group, one on the femoral side and two on the acetabular side. None were observed in the HXLPE group. No revision for aseptic loosening was reported in both cohorts.ConclusionPatients partaking in impact sports and receiving a ceramic-on-HXLPE THA demonstrated lower wear and osteolysis rates than those having a ceramic-on-cPE THA, with similar functional results.  相似文献   

4.
IntroductionYoung patients present a challenge for total hip arthroplasty (THA) survivorship. Highly cross-linked polyethylene (HXLPE) liners have decreased the prevalence of osteolysis; however, concerns exist regarding the biologic activity of wear particles. The purpose of this study was to determine the incidence and characteristics of osteolytic lesions in young HXLPE THA patients at an average 16-year follow up and determine the ability to detect osteolysis.MethodsWe performed a retrospective study involving 22 patients (26 THA) under age 50 at primary THA receiving HXLPE liners coupled with cobalt-chrome (CoCr) femoral heads. Computed tomography (CT) scans were reviewed for osteolysis. Chi-squared analysis was used for categorical variables and unpaired Kruskal-Wallis rank-sum test for continuous variables. Logistic regression was used to compare wear rates between those patients with and without osteolysis.ResultsThe mean age at surgery was 38.5 years. The mean time from surgery to CT scan was sixteen years (range 14.25–19.5 years). Nine of the 26 THA showed osteolysis. The mean volume of the lesions was 2.8 cm3. Linear (mean 0.008 mm/y) and volumetric (mean 4.5 mm3/year) wear rates were negligible. One-third of osteolytic lesions were visible on radiographs. Logistic regression failed to demonstrate a correlation between wear rates or UCLA activity score and osteolysis.ConclusionWe observed osteolysis in 35% of HXLPE THA in young patients at mean 16-year follow up despite zero revisions for wear-related problems and clinically insignificant wear rates.Level of EvidenceIV.  相似文献   

5.
BackgroundRevision of monoblock metal-on-metal (MoM) total hip arthroplasty (THA) is associated with high complication rates. Limited revision by conversion to a dual mobility (DM) without acetabular component extraction may mitigate these complications. However, the concern for polyethylene wear and osteolysis remains unsettled. This study investigates the results of DM conversion of monoblock MoM THA compared to formal acetabular revision.MethodsOne hundred forty-three revisions of monoblock MoM THA were reviewed. Twenty-nine were revisions to a DM construct, and 114 were complete revisions of the acetabular component. Mean patient age was 61, 54% were women. Components used, acetabular cup position, radiographic outcomes, serum metal ion levels, and HOOS Jr clinical outcome scores were investigated.ResultsAt 3.9 years of follow-up (range 2-5), there were 2 revisions (6.9%) in the DM cohort, 1 for instability and another for periprosthetic fracture. Among the formal acetabular revision group there was a 20% major complication rate (23/114) and 16% underwent revision surgery (18/114) for aseptic loosening of the acetabular component (6%), deep infection (6%), dislocation (4%), acetabular fracture (3%), or delayed wound healing (6%). In the DM cohort, there were no radiographic signs of aseptic loosening, component migration, or polyethylene wear. One DM patient had a small posterior metadiaphyseal femur lesion that will require close monitoring. There were no other radiographic signs of osteolysis. There were no clinically significant elevations of serum metal ion levels. HOOS Jr scores were favorable.ConclusionLimited revision with conversion to DM is a viable treatment option for failed monoblock MoM THA with lower complication rates than formal revision. Limited revision to DM appears to be a safe option for revision of monoblock MoM THA with a cup in good position and an internal geometry free of sharp edges or articular surface damage. Longer follow-up is needed to demonstrate any potential wear implications of these articulations.  相似文献   

6.
Background and purpose There is no substantial clinical evidence for the superiority of alternative bearings in total knee arthroplasty (TKA). We compared the short-term revision risk in alternative surface bearing knees (oxidized zirconium (OZ) femoral implants or highly crosslinked polyethylene (HXLPE) inserts) with that for traditional bearings (cobalt-chromium (CoCR) on conventional polyethelene (CPE)). The risk of revision with commercially available HXLPE inserts was also evaluated.

Methods All 62,177 primary TKA cases registered in a Total Joint Replacement Registry between April 2001 and December 2010 were retrospectively analyzed. The endpoints for the analysis were all-cause revisions, septic revisions, or aseptic revisions. Bearing surfaces were categorized as OZ-CPE, CoCr-HXLPE, or CoCr-CPE. HXLPE inserts were stratified according to brand name. Confounding was addressed using propensity score weights. Marginal Cox-regression models adjusting for surgeon clustering were used.

Results The proportion of females was 62%. Average age was 68 (SD 9.3) years, and median follow-up time was 2.8 (IQR 1.2–4.9) years. After adjustments, the risks of all-cause, aseptic, and septic revision with CoCr-HXLPE and OZ-CPE bearings were not statistically significantly higher than with traditional CoCr-CPE bearings. No specific brand of HXLPE insert was associated with a higher risk of all-cause, aseptic, or septic revision compared to CoCr-CPE.

Interpretation At least in the short term, none of the alternative knee bearings evaluated (CoCr-HXLPE or OZ-CPE) had a greater risk of all-cause, aseptic, and septic revision than traditional CoCr-CPE bearings.  相似文献   

7.
《The Journal of arthroplasty》2017,32(12):3796-3801
BackgroundThis study aimed at investigating differences in femoral head penetration between highly cross-linked polyethylene (HXLPE) cemented sockets and uncemented liners during 5 years postoperatively.MethodsNinety-six patients (106 hips) with a mean age of 64.4 (range, 35-83) years underwent total hip arthroplasty using a HXLPE cemented socket or liner and were respectively divided into cemented (35 patients [37 hips]) and uncemented (61 patients [69 hips]) groups. Femoral head penetrations were evaluated on both anteroposterior (AP)-view and Lauenstein-view radiographs, and mean polyethylene (PE) wear rates were calculated based on femoral head penetration from 2 to 5 years. Multivariate analyses were performed to assess risk factors for PE wear.ResultsAt 5 years postoperatively, the cemented and uncemented groups exhibited proximal direction femoral head penetrations of 0.103 mm and 0.124 mm (P = .226) and anterior direction penetrations of 0.090 mm and 0.151 mm (P = .002), respectively. The corresponding mean PE wear rates were 0.004 mm/y and 0.009 mm/y in the AP-view (P = .286) and 0.005 mm/y and 0.012 mm/y in the Lauenstein-view (P = .168), respectively. Left-side operation and high activity were independent risk factors for PE wear on AP-view.ConclusionWhen HXLPE was used, all mean PE wear rates were very low and those of cemented sockets and uncemented liners were very similar. PE particle theory suggests that the occurrence of osteolysis and related aseptic loosening might consequently decrease.  相似文献   

8.

Background

Concerns persist regarding the oxidative stability of annealed highly cross-linked polyethylene (HXLPE) and hence its wear performance especially long term in young and active patients. The purpose of this study is to assess the wear rates and clinical outcomes of a first-generation annealed HXLPE.

Methods

Forty-six patients (57 hips) with noncemented fixation, a mean age of 53 years, and a mean University of California Los Angeles activity score of 8 underwent primary total hip arthroplasty. A 28-mm femoral head against HXLPE liner was used in all cases. Linear wear rates were measured by 2 independent observers. Radiological and clinical assessments were recorded.

Results

At a mean of 14 years (range 10-17), the wear rate was 0.03 mm/y (SD ±0.02). There were no revisions for wear-related complications. Using revision for wear-related complications as an endpoint, the survivorship was 100% and we observed no osteolysis. Western Ontario and McMaster Universities Osteoarthritis Index, patient administered questionnaire, and Hospital for Special Surgery hip scores were 91/100, 5/100, and 37/40 respectively.

Conclusion

This study confirms that a first-generation annealed HXLPE shows excellent wear and clinical results at 10-17 years in young and active patients. Oxidative degradation of an annealed HXLPE does not adversely affect wear and shows no other wear-related complications.  相似文献   

9.
We evaluated the clinical and radiographic results of 67 (64 patients) cementless Duraloc-300 cups for young active patients after a mean follow-up period of 6.2 years. The preoperative mean Harris hip score improved from 46.24 to 96.5 points at 5 years. The survivorship of the cup, using radiographically confirmed aseptic loosening as the end point, was 100% at 5 years. The mean rate of liner wear was 0.125 mm/y (00-0.39 mm/y). Acetabular osteolysis was found in 14% (9 hips) of the 67 hips, and the osteolysis is related to polyethylene wear (P = .0024) and sex (P = .001). Although there was no aseptic loosening of the components, there was a high rate of liner wear of the polyethylene liner and acetabular osteolysis.  相似文献   

10.
BACKGROUND: We retrospectively reviewed 137 consecutive total hip arthroplasties performed with AML-A stems and Tri-Lock cups to see whether design modifications made to these components would achieve durable biological fixation in the Japanese population in whom developmental dysplasia of the hip (DDH) is relatively common. Patients from our initial clinical series using these components are available for more than 10 years' follow-up. METHODS: Between April 1988 and June 1994, we performed 137 total hip arthroplasties using the AML-A prosthesis for the patients with osteoarthritis of the hip joint. We excluded 26 hips with less than 10 years' follow-up and five hips from patients who died before the 10-year follow-up. The mean follow-up for the 105 remaining THAs is 155.2 months (range 120-237 months). The average age of these patients at the time of surgery was 53.1 years (range 22-81 years). RESULTS: In total, 17 THAs required component revisions. In seven cases, the first revision was limited to a liner exchange for polyethylene wear or osteolysis. Another seven hips underwent revision surgery for recurrent dislocation. Three cups have been revised owing to aseptic loosening. Because of the high incidence of wear-related revisions, Kaplan-Meier survivorship at the 15-year follow-up, using acetabular component revision for any reason as an endpoint, was 75.0% (95% CI 69.4%-83.8%). In contrast, no revision of the femoral stem was performed. Severe stress shielding occurred in 12 hips. Thigh pain was mild, however, and all of the femoral stems remained stable. CONCLUSIONS: Despite revisions for wear-related complications, the fixation achieved with these porous-coated components remained durable throughout the 15-year follow-up. Acetabular osteolysis has been associated with cup reoperation, but femoral stress shielding has never resulted in stem loosening.  相似文献   

11.
《The Journal of arthroplasty》2020,35(5):1417-1423
BackgroundLow polyethylene wear rate and low incidence of osteolysis have been reported after total hip arthroplasty (THA) using first-generation remelted highly cross-linked polyethylene (HXLPE). However, osteolysis has not been evaluated in long-term studies of these patients (15 years or more). The present study assessed computed tomography (CT) images to determine the incidence of osteolysis associated with HXLPE in THA during at least 15 years of follow-up.MethodsWe evaluated 105 primary THAs in 84 patients (77 women and 7 men). Mean follow-up was 15.9 years (range, 15-18 years). All THAs used a Longevity HXLPE liner and a 26-mm zirconia femoral head. Areas of osteolysis were identified from CT images using 3D and multiplanar reconstruction views.ResultsCT 3D multiplanar reconstruction images at 15-year follow-up showed no obvious osteolysis in the acetabulum or femur of any patient. No patients developed cup loosening or liner breakage.ConclusionOur study indicates that first-generation remelted HXLPE liners do not increase the risk of osteolysis during 15-year follow-up and suggests that the wear particles from first-generation remelted HXLPE are less biologically active than those generated by conventional polyethylene devices.  相似文献   

12.
《The Journal of arthroplasty》2023,38(3):535-540.e3
BackgroundIt is unknown if patients are relieved of pain after knee arthroplasty revision for unexplained pain. The aim of this cross-sectional case-control study was to compare patient-reported outcome measures (PROMs) and satisfaction 1 to 3 years after revision of total knee arthroplasties (TKAs) for the indications of unexplained pain versus aseptic loosening.MethodsWe included 384 patients undergoing TKA revision for the indications of unexplained pain and aseptic loosening from January 1, 2018 to December 31, 2020 from the Danish Knee Arthroplasty Register. A total of 81 patients were revised for unexplained pain and 303 for aseptic loosening. Questionnaires including PROMs (Oxford Knee Score, EQ-5D-5L, and Forgotten Joint Score) and satisfaction with the surgery on a 0-100 scale (100 = not satisfied; 0 = very satisfied) were sent to digitally secured mailboxes. Time from revision to data collection was a median 3.1 years (range, 1.4-4.4 years).ResultsMedian Oxford Knee Score was 25 (interquartile range [IQR] 15) versus 31 (IQR 18) 1-3 years after revisions for unexplained pain versus aseptic loosening, P = .009. Median EQ-5D-5L was 0.6 (IQR 0.4) versus 0.8 (IQR 0.3) for unexplained pain versus aseptic loosening, P = .009. Median Forgotten Joint Score was 50 (IQR 7) versus 50 (IQR 16) for unexplained pain versus aseptic loosening, P = .905. Satisfaction was 75 (IQR 38) for unexplained pain and 50 (IQR 73) for aseptic loosening, P < .001.ConclusionPatients undergoing TKA revision for the indication of unexplained pain had worse results on PROMs than those revised for aseptic loosening. Likewise, patients revised for unexplained pain were less satisfied compared to patients revised for aseptic loosening. This information is valuable to both surgeons and patients when candidates for revision surgery are selected, to obtain the best possible outcomes.  相似文献   

13.

Background

Polyethylene acetabular components are common in hip arthroplasty. Highly cross-linked polyethylene (HXLPE) has lower wear than ultra-high molecular weight polyethylene (UHMWPE). Evidence suggests that wear particles induce inflammation causing periprosthetic osteolysis contributing to implant loosening with wear rates of 0.05 mm/y were considered safe. We aimed to compare incidence and volume of periacetabular osteolysis between HXLPE and UHMWPE using computed tomography.

Methods

Initially, 54 hips in 53 patients were randomized to HXLPE or UHMWPE acetabular liner. At 10 years, 39 hips in 38 patients remained for the radiostereometric analysis' demonstrating significantly lower wear in the HXLPE group. At 12 years, 14 hips in 13 patients were lost to follow-up leaving 25 hips for computed tomography assessment. Images were reconstructed to detect osteolysis and where identified, areas were segmented and volumized.

Results

Osteolysis was observed in 8 patients, 7 from the UHMWPE group and only 1 from the HXLPE group (Fisher exact, P = .042). There was no correlation between the amount of polyethylene wear and osteolysis volume; however, the radiostereometric analysis-measured wear rate in patients with osteolysis from both groups was significantly higher than overall average wear rate.

Conclusion

This data demonstrates lower incidence of periacetabular osteolysis in the HXLPE group of a small cohort. Although numbers are too low to estimate causation, in the context of lower wear in the HXLPE group, this finding supports the hypothesis that HXLPE may not elevate osteolysis risk, and hence does not suggest that HXLPE wear particles are more biologically active than those generated by earlier generations of polyethylene.  相似文献   

14.
《The Journal of arthroplasty》2022,37(12):2333-2339
BackgroundDemographic variables play an important role in outcomes following revision total hip arthroplasty (rTHA). Surgical and in-patient variables as well as outcomes vary between indications for rTHA. The purpose of this study was to investigate the impact of the indication for the rTHA on costs and postoperative outcomes.MethodsThis retrospective cohort analysis investigated all patients who underwent unilateral, aseptic rTHA at an academic orthopaedic specialty hospital who had at least 1-year postoperative follow-up. In total, 654 patients were evaluated and categorized based on their indication for aseptic rTHA. Demographics, direct and total procedure costs, surgical factors, postoperative outcomes, and re-revision rates were collected and compared between indications.ResultsYounger patients had the greatest leg length discrepancy (LLD) and older patients had the highest incidence of periprosthetic fracture (PPF) (P = .001). The greatest proportion of full revisions were found for LLD (16.7%) and head/polyethylene liner-only revisions for metallosis/adverse tissue reaction (100%). Operative time was significantly longest for LLD revisions and shortest for metallosis/adverse tissue reaction revisions (P < .001). Length of stay was longest for periprosthetic fracture and shortest for LLD and stiffness/heterotopic ossification (P < .001). Re-revision rate was greatest for implant failure and lowest for LLD. Total cost was highest for PPF (148.9%) and lowest for polyethylene liner wear (87.7%).ConclusionsPatients undergoing rTHA for indications such as PPF and aseptic loosening were associated with longer operative times, length of stay and higher total and direct costs. Therefore, they may need increased perioperative attention with respect to resource utilization, risk stratification, surgical planning, and cost-reducing measures.Level III EvidenceRetrospective Cohort Study.  相似文献   

15.

Background

Concern regarding osteolysis attributable to polyethylene wear after TKA, particularly in younger patients, has prompted the introduction of highly crosslinked-remelted polyethylene (HXLPE) for TKAs. However, few in vivo comparative results of TKAs using HXLPE and less-crosslinked polyethylene inserts in the same patients are available, regarding fracture or failure of the locking mechanism of tibial polyethylene inserts or of osteolysis in patients younger than 60 years.

Questions/Purposes

We wanted to determine whether (1) survivorship free from aseptic loosening in knees with HXLPE inserts was different from survivorship in knees with less-crosslinked polyethylene inserts, (2) the prevalence of fracture or failure of the locking mechanism of the tibial polyethylene insert was greater in knees with HXLPE than in those with less-crosslinked polyethylene, and (3) the proportion of patients who had osteolysis develop was greater with HXLPE than with less-crosslinked polyethylene inserts.

Methods

One hundred seventy-one patients with a mean age of 58 ± 8 years (range, 35−59 years) received posterior cruciate-retaining prostheses with a less-crosslinked polyethylene tibial insert in one knee and a HXLPE tibial insert in the contralateral knee. From January 2007 to January 2010, we performed 366 same-day bilateral simultaneous sequential posterior cruciate-retaining TKAs in 183 patients, of whom 171 (93%) participated in this study. All patients during this study period underwent posterior cruciate-retaining TKAs regardless of deformity of the knees and we did not perform posterior-stabilized TKAs during the same period. Patients who had bilateral end-stage osteoarthritis and were younger than 60 years were selected for inclusion. Six patients (4%) were lost to followup before 5 years. Twenty-six patients were males and 145 were females. The mean duration of followup was 6 years (range, 5−8 years). At each followup, patients were assessed for loosening of the components, fracture or failure of the locking mechanism of the polyethylene inserts, or osteolysis.

Results

The survival rate of the knee prosthesis at a mean of 5.8 years after surgery was 100% (95% CI, 0.95–1.00) in both groups for the endpoint aseptic loosening and 99.4% (95% CI, 0.95–1.00) in both groups for the endpoint revision. No knee in either group had fracture or failure of the locking mechanism of the tibial polyethylene insert, and none had osteolysis.

Conclusions

With the numbers available, we found no clinically important differences between HXLPE and less-crosslinked polyethylene inserts in posterior cruciate-retaining TKAs. Given that HXLPE is newer, as-yet unproven, and more expensive than the proven technology (less-crosslinked polyethylene), we suggest not adopting HXLPE for clinical use until it shows superiority.

Level of Evidence

Level I, therapeutic study.  相似文献   

16.
BackgroundThe clinical and radiographic results of cementless total hip arthroplasty using a 32-mm cobalt-chromium head on remelted highly cross-linked polyethylene (HXLPE) and a tapered, fiber metal proximally coated femoral stem were evaluated at a mean follow-up of 12 years.MethodsA total of 57 cementless total hip arthroplasties using remelted HXLPE combined with a 32-mm cobalt-chromium head, and a tapered, fiber metal proximally coated femoral stem were performed from October 2004 to December 2006. Clinical evaluation was performed using the Merle d’Aubigné and Postel scoring system. Standardized anteroposterior and lateral radiographs of the pelvis and femur without weight-bearing were analyzed. Radiographic measurements of two-dimensional femoral head penetration into the polyethylene were performed with a computerized method. The steady-state wear rates were measured based on the radiographs from the first year after surgery to the final follow-up.ResultsThe mean Merle d’Aubigné and Postel score improved significantly from 10.7 points preoperatively to 15.6 postoperatively (P < .001). No osteolysis was found around the implant. Stem fixation in all cases showed stable bone ingrowth. Third-degree stress shielding was found in 46% of all stems. The total head penetration rate was 0.05 mm/y, and the steady-state wear rate was 0.01 mm/y. The Kaplan–Meier survivorship with the end point of revision was 95% (95% confidence interval, 85%-98%) at 12 years.ConclusionA 32-mm cobalt-chromium head on remelted HXLPE demonstrated low wear properties, and a tapered, fiber metal proximally coated femoral stem showed good results at long-term follow-up.  相似文献   

17.
《The Journal of arthroplasty》2023,38(9):1748-1753.e1
BackgroundLiterature regarding total knee arthroplasty (TKA) outcomes in sickle cell disease (SCD) is limited. Moreover, 10-year survivorship of SCD implants is unknown. This study aimed to observe 10-year cumulative incidence and indications for revision TKA in patients who did and did not have SCD.MethodsPatients who underwent primary TKA were identified using a large national database. The SCD patients were matched by age, sex, and a comorbidity index to a control cohort in a 1:4 ratio. The 10-year cumulative incidence rates were determined using Kaplan–Meier survival analyses. Multivariable analyses were conducted using Cox proportional hazard modeling. Chi-squared analyses were conducted to compare indications for revision between cohorts. In total, 1,010 SCD patients were identified, 100,000 patients included in the unmatched control, and 4,020 patients included in the matched control.ResultsCompared to the unmatched control cohort, SCD patients exhibited higher 10-year all-cause revision (HR: 1.86; P < .001) with higher proportions of revisions for periprosthetic joint infection (PJI) (P < .001), aseptic loosening (P < .001), and hematoma (P < .001). Compared to the matched control, SCD patients had higher 10-year all-cause revision (Hazard Ratio (HR): 1.39; P = .034) with a higher proportion of revisions for PJI (P = .044), aseptic loosening (P = .003), and hematoma (P = .019).ConclusionIndependent of other comorbidities, SCD patients are more likely to undergo revisions for PJI, aseptic loosening, and hematoma compared to patients who do not have SCD. Due to the high-risk of these complications, perioperative and postoperative surgical optimization should be enforced in SCD patients.  相似文献   

18.
《The Journal of arthroplasty》2022,37(9):1816-1821
BackgroundConventional polyethylene (CPE) was used widely in the past as a bearing surface in total hip arthroplasty (THA). As CPE THAs age and the revision burden continues to grow, it is increasingly important to understand the durability and failure mechanisms of this bearing material. Currently, such long-term data remain limited, particularly in younger, more active patients in whom wear issues are of greater concern.MethodsWe retrospectively reviewed 90 hips (77 patients) that underwent primary THA with CPE bearings on cobalt chrome femoral heads at age ≤50 years at 20-year minimum follow-up (mean 21.6 [20-23]). We analyzed polyethylene wear rates, clinical outcomes (modified Harris Hip Score, University of California, Los Angeles Activity Score), and implant survivorship.ResultsWear analysis revealed a median linear wear rate of 0.113 mm/y (95% CI 0.102-0.148) and a median volumetric wear rate of 41.20 mm3/y (95% CI 43.5-61.0). Modified Harris Hip Scores remained 37 points above preoperative baseline (P < .001) and University of California, Los Angeles scores 1.4 points above baseline (P = .018) at 21.6-year mean follow-up. Twenty-nine hips (32.2%) were revised, 20 of which (22.2%) were wear-related at a median of 15.4 years (interquartile range 11.4-19.5). Survivorship free from wear-related revision was 95.6% (95% CI 88.7-98.3), 87.9% (78.6-93.3), 78.1% (49.6-66.5), and 61.1% (41.3-67.0) at 10, 15, 20, and 25 years.ConclusionWear-related issues developed at increasingly high rates after 15 years, suggesting the need for surveillance after this time. The long-term wear and survivorship data of this study may be used as a benchmark when evaluating the performance of contemporary bearings in young, active THA patients.  相似文献   

19.
The purpose of this study was to investigate the results of 113 total hip arthroplasties in 109 patients using highly cross-linked polyethylene (HXLPE) after midterm (minimum 7 years) follow-up retrospectively. The mean age at the time of operation was 57 years. Preoperative diagnosis was osteonecrosis in 81 hips and other diagnosis in 32 hips. There was no component loosening. Acetabular osteolysis was found in 12 hips (10.6 %). Mean linear HXLPE wear rate was 0.031 ± 0.012 mm/y. We analyzed the relationship between HXLPE wear rate and several variables influencing HXLPE wear. Only the cup position was related with wear rate of HXLPE significantly (P < .05). The results of total hip arthroplasties using HXLPE showed excellent results with decreased wear rate and low incidence of osteolysis after midterm follow-up.  相似文献   

20.
BackgroundIsolated liner exchange is an option to address polyethylene wear after total hip arthroplasty (THA). The liner can be fixed with either the original locking mechanism or cemented into the acetabular cup. Whether the method used for liner fixation has any bearing on the outcomes in the first and second decade after surgery is still unclear.MethodsData for all patients who had undergone isolated liner exchange surgery in our institution between April 1995 and January 2015 were retrieved. Patients were classified according to the type of polyethylene liner (conventional or highly crosslinked polyethylene) and the locking mechanism used (original locking mechanism or cemented). Survivorship and revision rates were compared among different subgroups. A total of 118 isolated liner exchanges were performed and patients had a mean duration of follow-up of 13 years (range, 5 to 25).ResultsOverall estimated mean survivorship was 17 years. Use of highly crosslinked polyethylene (HXLPE) had a lower re-revision rate compared to conventional liners (10.5 versus 46.9%) (P < .001). The re-revision rate of exchanges using HXLPE was not affected by the type of fixation (original locking mechanism 11.1 versus cement 10.0%, P = .868). Conversely, using the original locking mechanism with a conventional liner had a higher re-revision rate compared to cemented conventional liners (58.3 versus 12.5%) (P = .024).ConclusionHXLPE liners should be used in insert exchange surgery whenever possible. Re-revision rate of exchanges using HXLPE was not affected by the fixation technique used. Cementing an insert into an acetabular component is associated with good survivorship at a mean of 13 years follow-up.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号