Background and purpose — Ceramic-on-ceramic (CoC) bearings were introduced in total hip arthroplasty (THA) to reduce problems related to polyethylene wear. We compared the 9-year revision risk for cementless CoC THA and for cementless metal-on-polyethylene (MoP) THA.

Patients and methods — In this prospective, population-based study from the Danish Hip Arthroplasty Registry, we identified all the primary cementless THAs that had been performed from 2002 through 2009 (n = 25,656). Of these, 1,773 THAs with CoC bearings and 9,323 THAs with MoP bearings were included in the study. To estimate the relative risk (RR) of revision, we used regression with the pseudo-value approach and treated death as a competing risk.

Results — 444 revisions were identified: 4.0% for CoC THA (71 of 1,773) and 4.0% for MoP THA (373 of 9,323). No statistically significant difference in the risk of revision for any reason was found for CoC and MoP bearings after 9 years of follow-up (adjusted RR = 1.3, 95% CI: 0.72–2.4). Revision rates due to component failure were 0.5% (n = 8) for CoC bearings and 0.1% (n = 6) for MoP bearings (p < 0.001). 6 patients with CoC bearings (0.34%) underwent revision due to ceramic fracture.

Interpretation — When compared to the “standard” MoP bearings, CoC THA had a 33% higher (though not statistically significantly higher) risk of revision for any reason at 9 years.  相似文献   

2.
BackgroundMetal-on-metal (MoM) revisions have shown high rates of complications from aseptic loosening, deep infection, and dislocation. The purpose of this study is to report on outcomes and complications of a large consecutive series of patients who were revised for failed MoM total hip arthroplasty (THA).MethodsWe evaluated 188 patients (203 hips) who underwent revisions of failed MoM THA. Mean age at the revision was 60 years old. Gender was female in 112 hips (55%) and male in 91 hips (45%). Mean interval to failure after primary THA was 4.9 years (range, 0-18 years). The acetabular component was revised in 183 cases (92%). Clinical outcomes assessed included pain score and Harris hip score.ResultsMean follow-up from revision was 4.2 years. Harris hip score improved from 53.6 pre-revision to 73.5 at most recent follow-up (P < .001). Pain level significantly improved from 17.2 pre-revision to 32.8 post-revision (P < .001). Reoperations occurred in 28 (14%) hips. Re-revision was required in 16 hips (7.9%). The most common reasons for re-revision were aseptic loosening (5), dislocation (3), infection (2), and iliopsoas tendonitis (2). Re-revision was significantly higher in cases of pseudotumor. There was no difference in survival with ultraporous cups. Three hips required re-revision to custom triflange components. All-cause survival was 90.5% at 4.2 years. Metal ion levels significantly declined after revision.ConclusionRevisions of failed MoM THA showed improvements in clinical outcomes, but present significant surgical challenges and complications especially in cases with soft tissue damage and pseudotumor.  相似文献   

3.
Background and purpose — Patient-reported outcome (PRO) is recognized as an important tool for evaluating the outcome and satisfaction after total hip arthroplasty (THA). We wanted to compare patient-reported outcome measure (PROM) scores from patients with ceramic-on-ceramic (CoC) THAs and those with metal-on-metal (MoM) THAs to scores from patients with metal-on-polyethylene (MoP) THAs, and to determine the influence of THA-related noise on PROM scores.

Patients and methods — We conducted a nationwide cross-sectional questionnaire survey in a cohort of patients identified from the Danish Hip Arthroplasty Registry. The PROMs included were: hip dysfunction and osteoarthritis and outcome score (HOOS), EQ-5D-3L, EQ VAS, UCLA activity score, and questions about noise from the THA. The response rate was 85% and the number of responders was 3,089. Of these, 45% had CoC THAs, 17% had MoM THAs, and 38% had MoP THAs, with a mean length of follow-up of 7, 5, and 7 years, respectively.

Results — Compared to MoP THAs, the mean PROM scores for CoC and MoM THAs were similar, except that CoC THAs had a lower mean score for HOOS Symptoms than did MoP THA. 27% of patients with CoC THAs, 29% with MoM THAs, and 12% with MoP THAs reported noise from their hip. For the 3 types of bearings, PROM scores from patients with a noisy THA were statistically significantly worse than those from patients with a silent MoP THA. The exception was noisy CoC and MoM THAs, which had the same mean UCLA activity score as silent MoP THAs.

Interpretation — A high proportion of patients reported noise from the THA, and these patients had worse PROM scores than patients with silent MoP THAs.  相似文献   


4.

Background

Dislocation is a major complication after primary total hip arthroplasty (THA), but little is known about the potential relationships between bearing materials and risk of dislocation. Dislocation within the first year after surgery is typically related to either surgical error or patient inattention to precautions, but the reasons for dislocation after the first year are often unclear, and whether ceramic bearings are associated with an increased or decreased likelihood of late dislocation is controversial.

Questions/purposes

The purpose of this study was to use a national registry to assess whether the choice of bearings–metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), ceramic-on-ceramic (CoC), or metal-on-metal (MoM)–is associated with differences in the risk of late dislocation.

Methods

Data from primary THAs were extracted from the New Zealand Joint Registry over a 10-year period. The mean age of patients was 69 years (SD ± 12 years), and 53% were women. The median followup in this population was 7 years (range, 1–13 years). The surgical approach used was posterior in 66% of THAs, lateral in 29%, and anterior in 5%. The primary endpoint was late revision for dislocation with “late” defined as greater than 1 year postoperatively. A total of 73,386 hips were available for analysis: 65% MoP, 17% CoP, 10% CoC, and 7% MoM. In general, patients receiving CoC and MoM bearings were younger compared with patients receiving CoP and MoP bearings.

Results

Four percent of the hips were revised (3130 THAs); 867 THAs were revised for dislocation. Four hundred seventy THAs were revised for dislocation after the first postoperative year. After adjusting for head size, age, and surgical approach, only CoP (hazard ratio [HR], 2.10; p = 0.021) demonstrated a higher proportion of revision, whereas MoP did not (HR, 1.76; 95% p = 0.075). There were no differences of revisions for dislocation in the CoC (HR, 1.60; p = 0.092) and MoM cohorts (HR, 1.54; p = 0.081).

Conclusions

Dislocation is a common reason for revision after THA. The relationships between bearing materials and risk of revision for late dislocation remain controversial. This large registry study demonstrated that bearing surface had little association with the incidence of late dislocation. Future studies with longer followups should continue to investigate this question.

Level of Evidence

Level III, therapeutic study.  相似文献   

5.
《The Journal of arthroplasty》2021,36(10):3490-3497
BackgroundThis study examines cobalt levels and pseudotumor characteristics in a non-recalled modular femoral prosthesis. We sought to determine relationships between serum cobalt levels and pseudotumors following modular and metal-on-metal (MoM) total hip arthroplasty (THA), the location and size of pseudotumors, and changes to pseudotumor grade over time.MethodsWe retrospectively evaluated a cohort of 190 primary THAs implanted with a dual-modular femoral stem by one surgeon from 2005 to 2013. One hundred seventeen THAs used a cobalt-chromium modular neck (CoCrMN) component and non-MoM articulation, 63 THAs had a titanium neck component and MoM articulation, and 10 had a titanium neck component and polyethylene liner. Serum ion levels were recorded for all patients. Pseudotumor grade and location were measured by musculoskeletal-trained radiologists.ResultsCobalt levels did not correlate to time after index arthroplasty. In the CoCrMN group, cobalt levels were elevated in 11 of 19 (57.9%) patients with pseudotumor compared to 14 of 19 (73.7%) in the MoM group. Pseudotumors were more often located lateral to the hip joint in the CoCrMN group compared to anteromedial following MoM arthroplasty. In CoCrMN THAs, pseudotumors were visualized in 12 of 51 (23.5%) initial MARS MRIs within 40 months compared to 5 of 66 (7.6%) performed later (P = .02).ConclusionPseudotumor characteristics differ between patients with CoCrMN designs vs those with an MoM articulation. Normal serum cobalt levels did not exclude the presence of a pseudotumor and routine MARS MRI should be included in follow-up of patients with this CoCrMN prostheses.  相似文献   

6.
BackgroundMetal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) has recently gained increased utilization as a screening modality in patients with a total hip arthroplasty (THA). Fluid collections have been documented in asymptomatic patients with various bearing surfaces. The purpose of this study is to determine the frequency and types of MARS MRI-documented abnormalities in asymptomatic patients with a ceramic-on-ceramic (CoC) THA.MethodsThirty-seven patients (42 hips) with a minimum 2-year follow-up after THA with CoC THA implants were enrolled in this study. The inclusion criteria were the absence of hip pain and the availability of appropriate follow-up radiographs. All patients underwent a MARS MRI. Abnormalities were documented using a previously described method.ResultsFluid collections were observed in 8 (19%) asymptomatic hips in this cohort. Four of the 8 hips demonstrated intracapsular synovitis, and 3 of these hips had a thickened synovium. Extra-articular fluid collections with direct intra-articular communication were identified in 4 hips, with 2 of these hips demonstrating synovial thickening. No signs of osteolysis were noted on radiographs or the MARS MRI scans.ConclusionAsymptomatic fluid collections occur in patients after CoC THA similar to other bearing surfaces. We continue to follow these patients in an effort to determine the clinical significance and natural history of these findings.Level of EvidenceDiagnostic Level IV.  相似文献   

7.
8.
Background:Most literature in the field of total hip arthroplasty (THA) for fused hips, until date has reported the results of using metal on polyethylene and ceramic on polyethylene bearings. Results of THA using ceramic on ceramic (CoC) bearings in fused hips have not been published in literature. This study reports the results of cementless THA using CoC articulation perfomed in fused hips.Results:Mean Harris hip score improved from 42.4 to 84.2 and mean leg lengthening of 36.6 mm was achieved. In the average 5.4 years (range 2.8-9.1 years) followup there were no cases with osteolysis around acetabular cup and femoral stem. In this study, there was no case of ceramic fracture. There was one case of squeaking.Conclusion:This study suggests that cementless THA performed for fused hips with CoC bearings can provide good early clinical results.  相似文献   

9.
《The Journal of arthroplasty》2023,38(8):1539-1544
BackgroundThere are limited long-term results of using ceramic-on-ceramic (CoC) bearings in total hip arthroplasty (THA) in a large number of patient cohorts. The purpose of this study was to evaluate the minimum 10-year clinical and radiological outcomes and survivorship in a single surgeon series of CoC-THA.MethodsAmong the 1,039 patients (1,391 hips) who underwent primary THA at our institution between 2008 and 2011, 49 patients (69 hips) experienced paralysis or death, and 194 patients (239 hips, 19%) were lost to follow-up. The remaining 796 patients (1,083 hips) were assessed at a mean of 11 years (range, 10 to 13 years) using the modified Harris hip score (mHHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and a questionnaire on articular noises. Survival analysis was used to estimate the survivorship. Radiological evaluation was performed on 869 hips at the final follow-up.ResultsSurvivorship at 11 years was 98.3% for revision or aseptic loosening, and 98.2% for reoperation. At the final follow-up, the mean mHHS and WOMAC scores were 93 (range, 12 to 100) and 14.4 (range, 3 to 66), respectively. There were 131 (12%) hips that experienced squeaking, but no patient required revision. No fracture of the ceramic was observed. Radiological evaluation at the final follow-up revealed that 3 (0.3%) hips exhibited loosening, 2 (0.2%) had femoral osteolysis, 81(9.3%) acquired radiolucencies, and 35 (4%) showed heterotopic ossification.ConclusionThis CoC bearing for THA had a high survivorship and excellent functional outcomes for at least 10 years.  相似文献   

10.
《The Journal of arthroplasty》2020,35(11):3230-3236.e3
BackgroundThe purpose of this study is to determine if there is a difference in echocardiographic results between patients with metal-on-metal (MoM) vs non-MoM total hip arthroplasty (THA) and to determine if a correlation exists between serum metal levels and echocardiographic outcomes.MethodsSeventy-five patients with the same modular THA enrolled in this prospective cohort study, and 49 had MoM bearings. All patients had serum cobalt, chromium, and titanium levels drawn at 2 study visits with a transthoracic echocardiogram at the second visit. Serum metal concentrations and echocardiographic parameters were compared with 2-way t-tests. Multiple linear regression analyses identified any significant predictors of echocardiographic outcomes.ResultsMean serum cobalt and chromium levels were significantly greater in the MoM group at both time-points (P < .001 and P < .05, respectively). Titanium levels were similar between groups (P > .05). MoM patients had significantly lower global longitudinal strain compared with the non-MoM group (18.4% vs 20.2%; P = .026). Serum cobalt concentration was found to be an independent predictor of tricuspid annular plane systolic excursion (P = .02).ConclusionMoM THA bearings are associated with increased serum cobalt and chromium levels. Patients with MoM THAs had decreased global longitudinal strain, a measure of left ventricular function, but both groups remained within normal range. The clinical impact of the positive association between serum cobalt concentration and tricuspid annular plane systolic excursion, a marker of right ventricular function, deserves further study. These findings can reassure physicians and patients that metal-induced cardiomyopathy is not typical in the setting of MoM THA.Level of EvidenceLevel II, Prospective Cohort Study.  相似文献   

11.
The purpose of this study was to present national trends in primary total hip arthroplasty (THA) and bearing surface usage for patients 30 years and younger. Using the Healthcare-Cost-and-Utilization-Project Nationwide Inpatient Sample for the years 2006 to 2009, 8919 primary THA discharges (4454 coded by bearing surface) were identified in patients 30 years and younger. The most commonly used bearing surface was metal-on-metal (MoM), representing 37.6% of cases, followed by ceramic-on-ceramic (CoC) (24.6%), metal-on-polyethylene (MoP) (22.1%) and ceramic-on-polyethylene (15.7%). From 2006 to 2009, the percentage of THAs that used hard-on-hard bearing surfaces decreased (MoM: 42.9%-29.4%; CoC: 34.0%-19.7%).This decrease in hard-on-hard bearing surface usage presents a challenge for surgeons treating young patients to find other acceptable durable bearings that do not have the potential problems associated with MoM or CoC.  相似文献   

12.
ObjectiveTo report the long‐term outcomes of total hip arthroplasty (THA) with fourth‐generation ceramic‐on‐ceramic (CoC) bearing in patients with ankylosing spondylitis (AS).MethodsWe retrospectively identified 180 primary THAs performed in 110 patients with AS, including 100 (90.9%) men and 10 women (9.1%), from 2009 to 2011.The mean age of the patients at surgery was 33 years (range, 16 to 65 years). Cementless prostheses with fourth‐generation CoC bearings were used in all patients. Survivorship of the implants and postoperative complications were calculated. Functional improvement was assessed by the hip flexion‐extension range of motion (ROM) and Harris hip score (HHS). A special noise assessment questionnaire was performed at the last follow‐up. The cumulative incidence of noise was calculated by the Kaplan–Meier method with 95% confidence intervals (CIs). Clinical characteristics and functional outcomes were compared in the hips with noise to those without noise.ResultsThe mean follow‐up was 11 years (range, 10 to 12 years), and survivorship of the implants was 99.4% at the most recent follow‐up. The complications included dislocation (one hip, 0.6%), periprosthetic joint infection (one hip, 0.6%), mild to moderate pain (five hips, 2.8%), heterotopic ossification (12 hips, 6.7%), and noise (52 hips, 28.9%). The flexion‐extension ROM improved significantly with a median from 10° (range, 0 ~ 130°) to 100° (30 ~ 130°) after THA (p < 0.001), and the HHS increased significantly from 41 ± 20 to 90 ± 8 (p < 0.001). The cumulative incidence of noise at 0.5, 5, and 10 years was 6.1% (95% CI, 2.6 ~ 9.6), 16.7% (95% CI, 11.2 ~ 22.1), and 28.9% (95% CI, 22.2 ~ 35.5), respectively, and that of squeaking at 0.5, 5, and 10 years was 4.4% (95% CI, 1.4 ~ 7.4), 13.3% (95% CI, 8.4 ~ 18.3), and 23.9% (95% CI, 17.6 ~ 30.1), respectively. None of the patients with noise generation in the hip reported it affecting daily activities or causing dissatisfaction. No differences in age, sex, BMI, disease duration, bilateral THA, the frequency of bony ankylosis, the proportion of using a 36‐mm‐diameter femoral head, pre/postoperative flexion‐extension ROM, or pre/postoperative HHS were found between hips with noise and those without noise (p > 0.05).ConclusionTHAs with fourth‐generation CoC bearings exhibit excellent long‐term survival and clinical outcomes in patients with AS, with a very low dislocation rate. The incidence of noise associated with CoC bearings in THA performed in patients increases over time, but it does not affect postoperative hip function or daily activities.  相似文献   

13.
14.

Introduction

Hard-on-hard (HoH) bearing surfaces in total hip arthroplasty (THA) are commonly utilized in younger patients and may decrease mechanical wear compared to polyethylene bearing surfaces. To our knowledge, no study has prospectively compared the 2 most common HoH bearings, ceramic-on-ceramic (CoC) and metal-on-metal (MoM) THA.

Materials and Methods

We prospectively enrolled 40 patients to undergo an MoM THA and 42 patients to undergo a CoC THA utilizing the same acetabular component. Patients were followed up for a minimum of 2 years. Comparative outcomes included clinical scores, revision or reoperation for any reason, complication rates, and radiographic outcomes.

Results

The average follow-up was significantly longer in the CoC cohort (94 vs 74 months; P = .005). The CoC cohort had significantly improved Harris Hip Scores (95 vs 84; P = .0009) and pain scores (42 vs 34; P = .0003). The revision (0% vs 31%; P = .0001), reoperation (7.5% vs 36%; P = .004), and complication rates (10% vs 56%; P = .0001) were significantly lower in the CoC cohort. There were no statistically significant differences in radiographic parameters.

Conclusion

The clinical outcomes in the CoC cohort exceeded the MoM cohort. It is unlikely that another prospective comparative study of HoH THAs will be conducted. Our midterm results support the use of CoC THA as a viable option that may reduce long-term wear in younger patients. Close surveillance of MoM THA patients is recommended considering the higher failure and complication rates reported in this cohort.  相似文献   

15.
BackgroundTo report clinical outcomes and survival at a minimum of 10 years of a consecutive series of uncemented total hip arthroplasty (THA) with fourth-generation ceramic-on-ceramic (CoC) bearings and determine the incidence of articular noises, their risk factors, and impact on quality of life (QoL).MethodsFrom a series of 456 CoC THAs, there were 25 revisions, 38 deceased, and 36 lost to follow-up. The remaining 357 hips were assessed at 11.1 ± 0.7 years (range, 10-14) using the Forgotten Joint Score, Oxford Hip Score, and a questionnaire on articular noises. Kaplan-Meier survival was calculated, and multivariable analysis was performed to determine associations between articular noise and patient/surgical factors.ResultsThe 10-year survival was 96.3% for the cup, 96.5% for the stem, and 94.2% for all components. The Forgotten Joint Score was 79 ± 26 (range, 0-100), and Oxford Hip Score was 16 ± 7 (range, 12-60). The mean impact of articular noises on QoL was 1.8 ± 2.9 (range, 0-9): considered negligible in 60 hips (16%), moderate in 27 hips (7%), and severe in only 13 hips (4%). Multivariable analyses revealed that the incidence of articular noise decreased with age (odds ratio [OR], 0.94; P = .001), body mass index (OR, 0.85; P = .001), and in hips implanted with 32-mm (vs 36 mm) heads (OR, 0.18; P = .030).ConclusionOf 100 hips (28%) that reported some articular noises 10 years after CoC THA, the impact of articular noises on QoL was negligible for most patients. Although larger heads can improve mobility and reduce risks of dislocations, surgeons must be aware that increasing head size could also increase risks of articular noises, notably in young and active patients.  相似文献   

16.
17.

Background

Pseudotumors are a common finding in metal-on-metal (MoM) total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA). However, information on pseudotumors in metal-on-polyethylene (MoP) THA is limited.

Methods

One hundred eleven patients with 148 hip articulations—30 MoM THA, 47 MoM RHA, and 71 MoP THA—participated in a cross-sectional study at mean 7.1 (range: 0.2-21.5) years postoperatively. Patients were evaluated with metal artifact reducing sequence magnetic resonance imaging, measurements of metal ions, clinical scores of Harris Hip Score, Oxford Hip Score, the Copenhagen Hip and Groin Outcome Score, and conventional radiographs.

Results

Pseudotumors were present in 13 of 30 (43%) MoM THA, 13 of 47 (28%) MoM RHA, and 29 of 71 (41%) MoP THA patients, which was a similar prevalence (P = .10). The prevalence of mixed or solid pseudotumors was significantly higher in patients with MoP THA (n = 10) compared to MoM THA (n = 3) and MoM THA (n = 0), (P = .01). Hips with a mixed or solid pseudotumor had significantly poorer scores of Harris Hip Score (P = .01) and OHS (P = .002) and higher metal ion levels of cobalt (P = .0009) compared to hips without a pseudotumor or with a cystic pseudotumor.

Conclusion

Pseudotumors have primarily been associated with MoM hip articulations, but we found a similar pseudotumor prevalence in MoP THA, which is the most common bearing worldwide. Mixed or solid pseudotumors were more often seen in MoP THA compared with MoM hip articulations, and patients with a mixed or solid pseudotumor had poorer clinical scores and higher metal ion levels than patients without a pseudotumor or with a cystic pseudotumor.  相似文献   

18.

Background

We analyzed the data for primary total hip arthroplasty (THA) in the Korean nationwide database to assess (1) the epidemiology and national trends of bearing surface usage in THAs and (2) the prevalence of each type of bearing surface according to age, gender, hospital type, primary payer, and hospital procedure volume.

Methods

A total of 30,881 THAs were analyzed using the Korean Health Insurance Review and Assessment Service database for 2007 through 2011. Bearing surfaces were sub-grouped according to device code for national health insurance claims and consisted of ceramic-on-ceramic (CoC), metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), and metal-on-metal (MoM). The prevalence of each type of bearing surface was calculated and stratified by age, gender, hospital type, primary payer, and procedure volume of each hospital.

Results

CoC was the most frequently used bearing surface (76.7%), followed by MoP (11.9%), CoP (7.3%), and MoM (4.1%). The proportion of THAs using a CoC bearing surface increased steadily from 71.6% in 2007 to 81.4% in 2011, whereas the proportions using CoP, MoP, and MoM bearing surfaces decreased. The order of prevalence was identical to that in the general population regardless of age, gender, hospital type, primary payer, and hospital procedure volume.

Conclusions

The trends and epidemiology of bearing surface usage in THAs in Korea are different from those in other countries, and the CoC bearing surface is the most prevalent articulation. In future, the results of a large-scale study using nationwide data of THAs involving a CoC bearing surface will be reported in Korea.  相似文献   

19.
Metal-on-metal (MoM) bearings for total hip arthroplasty (THA) have come under scrutiny with reports of high failure rates. Clinical outcome studies with several commercially available MoM THA bearings remain unreported. We evaluated 78 consecutive MoM THAs from a single manufacturer in 68 patients. Sixty-six received cobalt–chrome (CoCr) monoblock and 12 received modular titanium acetabular cups with internal CoCr liners. Femoral components were titanium with modular necks. At average 2.1 years postoperatively, 12 THAs (15.4%) demonstrated aseptic failure (10 revisions, 2 revision recommended). All revised hips demonstrated capsular necrosis with positive histology reaction for aseptic lymphocytic vasculitis-associated lesions/adverse local tissue reactions. Prosthetic instability following revision surgery was relatively common. Female gender was a strong risk factor for failure, though smaller cups were not. Both monoblock and modular components fared poorly. Corrosion was frequently observed around the proximal and distal end of the modular femoral necks.  相似文献   

20.

Background:

Recent studies have recommended the discontinuation of metal-on-metal (MoM) components in total hip arthroplasty (THA) because of adverse effects reported with large-diameter MoM THA. This is despite favorable long-term results observed with 28 and 32 mm MoM bearings.

Questions/purposes:

The aim of this study was to assess the value of calls for an end to MoM bearings as THA components. Specifically, we wish to address the risks associated with MoM bearings including adverse soft tissue reactions, metal ion release, and carcinogenic risk.

Methods:

The study evaluates the arguments in the literature reporting on MoM (adverse soft tissue reactions, metal ion release, and carcinogenic risk) and the experience of the current authors who re-introduced these bearings in 1995. They are balanced by a benefit–risk review of the literature and the authors’ experience with MoM use.

Results:

Adverse reactions to metallic debris as well as metal ion release are predictable and can be prevented by adequate design (arc of coverage, clearance), metallurgy (forged instead of cast alloy, high-carbide content), and appropriate component orientation. There is no scientific evidence that carcinogenicity is increased in subjects with MoM hip prostheses. MoM articulations appear to be attractive allowing safe hip resurfacing, decreasing the risk of THA revision in active patients, and providing secure THA fixation with cement in cages in severely deformed hips. MoM bearings in women of child-bearing age are controversial, but long-term data on metallic devices in adolescents undergoing spinal surgery seem reassuring.

Discussion:

Adequate selection of MoM articulations ensures their safe use. These articulations are sensitive to orientation. Fifteen years of safe experience with 28- and 32-mm bearings of forged alloy and high-carbide content is the main reason for retaining them in primary and revision THA.  相似文献   