共查询到20条相似文献,搜索用时 15 毫秒
1.
Christoper E. Pelt Wes MadsenJill A. Erickson PA-C Jeremy M. GilillandMike B. Anderson MS ATC Christopher L. Peters MD 《The Journal of arthroplasty》2014
We retrospectively reviewed 123 patients who underwent cementless THA with modular femoral stem designs for revision THA or conversion of failed ORIF and found 75 patients available for analysis. The Harris Hip Score (HHS) improved from 52 ± 14 to 86 ± 11 (P < 0.001). The femoral stem was re-revised in eight patients (11%). The mean time to re-revision was 1.1 years (0.13–2.54). Reasons for re-revision included infection (n = 5, 7%), aseptic loosening (n = 2, 3%) and significant pain (n = 1, 1%). There were no failures of the modular junctions. PC stems had an increased rate of intraoperative fractures (PC 28% vs. STS 9%, P = 0.04). Modular cementless femoral stems provide acceptable mid-term results in revision THA. 相似文献
2.
《The Journal of arthroplasty》2023,38(5):855-861.e1
BackgroundCementless total hip arthroplasty (THA) femoral stems are the most commonly selected prostheses in the United States. Optimal stem geometry remains controversial with excellent survivorship reported for many designs. We compared cause-specific stem revision of single-wedge versus double-wedge designs from a multicenter US cohort.MethodsData from an integrated healthcare network’s total joint replacement registry were used to conduct a cohort study. Primary elective cementless THAs were identified (2001 to 2018). Implant exposure groups were classified by design geometry using the system proposed by Khanuja et al. Type 1 single-wedge (n = 11,082) and type 2 double-wedge (n = 32,380) designs were compared, and other design types were excluded; the final study cohort comprised 43,462 THAs. Cause-specific multivariable Cox regressions were used to evaluate risk for revision due to infection or aseptic reasons, including loosening, instability, periprosthetic fracture, or other reasons.ResultsAfter adjustment for covariates, a higher aseptic revision risk was observed for type 1 when compared to type 2 designs (hazard ratio = 1.91, 95% confidence interval = 1.33-2.75). When looking at specific revision reasons, revision for aseptic loosening (hazard ratio = 3.46, 95% confidence interval = 2.24-5.34) was higher for type 1 versus type 2 designs. No differences were found for septic revision, instability, periprosthetic fracture, or revisions for other reasons.ConclusionsType 1 single-wedge designs were found to have a higher risk of revision due to aseptic loosening relative to type 2 double-wedge designs. Femoral stem geometry should be considered when selecting a cementless femoral implant.Level of EvidenceLevel III. 相似文献
3.
《The Journal of arthroplasty》2021,36(9):3269-3274
BackgroundIn revision total hip arthroplasty (THA) cases with preserved femoral metaphyseal bone, tapered proximally porous-coated “primary” femoral stems may be an option. The objective of this study was to compare outcomes of patients with Paprosky I or II femoral bone loss undergoing revision THA with either a primary metaphyseal-engaging cementless stem or a revision diaphyseal-engaging stem.MethodsThis was a retrospective analysis of 70 patients with Paprosky I or II femoral bone loss who underwent femoral revision. 35 patients who were revised using a primary cementless femoral stem were compared with 35 patients who underwent femoral revision using a revision diaphyseal-engaging stem. The groups were similar regarding age, gender, body mass index, and American Society of Anesthesiologists. Clinical and radiographic outcomes and complications were compared over an average follow-up of 2.9 years (SD 1.4).ResultsRevision THA was most commonly performed for periprosthetic joint infection (N = 27, 38.6%). The groups were similar with regards to Paprosky femoral classification (P = .56), length of stay (P = .68), discharge disposition (P = .461), operative time (P = .20), and complications (P = .164). There were no significant differences between primary and revision femoral stem subsidence (0.12 vs. 0.75 mm, P = .18), leg length discrepancy (2.3 vs. 4.05 mm, P = .37), and Hip Disability and Osteoarthritis Outcome Score Jr (73.1 [SD 21.1] vs. 62.8 [SD 21.7], P = .088). No patient underwent additional revision surgery involving the femoral component.ConclusionUse of modern primary cementless femoral stems is a viable option for revision hip arthroplasty in the setting of preserved proximal femoral metaphyseal bone. Outcomes are not inferior to those of revision stems and offer potential benefits. 相似文献
4.
We describe the use of a fully hydroxylapatite-coated long-stem femoral implant in a series of 40 complex revision total hip arthroplasties. All reconstructions involved severe bone loss or malalignment and were accomplished entirely without the use of augmentary bone graft. Outcomes were evaluated at 7 minimum years of follow-up (average, 10.2 years). Three stems were rerevised because of infection, trauma, and loosening with nonunion of a fracture. Bone ingrowth was radiographically evident by one postoperative year in all other cases. There were no cases of subsidence. Stress shielding with thigh pain was seen in one patient. The stem provided immediate stability and excellent long-term fixation in these reconstructions of severely diseased femurs. 相似文献
5.
Omar A. Behery Sean M. Kearns Justin M. Rabinowitz Brett R. Levine 《The Journal of arthroplasty》2017,32(5):1510-1515
Background
The ideal fixation for modern tibial components in total knee arthroplasty (TKA) remains controversial with uncertainty on whether cementless implants can yield equivalent outcomes to cemented fixation in early follow-up.Methods
A series of 70 consecutive cases with reverse hybrid cementless fixation were matched to 70 cemented cases from 2008 to 2015 based on implant design and patient demographics.Results
Cementless TKA demonstrated greater aseptic loosening (7 vs 0, P = .013) and revision surgery (10 vs 0, P = .001) than cemented fixation within 5 years of follow-up, but with no clinically significant differences in outcome scores.Conclusion
It remains unclear whether early aseptic loosening in cementless TKA can be reduced with enhanced adjunct fixation and what proportion of early failure justifies the potential lifelong fixation through biologic ingrowth of cementless tibial components. 相似文献6.
Sergio Romagnoli Matteo Marullo Michele Corbella Enrico Zero Andrea Parente Marco Bargagliotti 《The Journal of arthroplasty》2021,36(3):1080-1086
BackgroundRevision of a failed total hip arthroplasty (THA) poses technical challenges. The use of primary stems for revision can be advantageous for maintaining bone stock and reducing complications: small case series have reported promising results in the short-term to mid-term follow-up. The aim of this study was to evaluate the long-term clinical and functional results and survivorship of a consecutive series of THA femoral component revisions using a conical primary cementless stem (PCS).MethodsNinety-four stem revisions with a preoperative Paprosky I or II defect were analyzed at an average follow-up of 12.7 ± 5.4 years. Aseptic loosening was the reason for revision in 92.5% of cases. Twenty patients were lost to follow-up. Two subgroups were created: Group 1 (n = 59) underwent isolated stem revision; Group 2 (n = 15) underwent complete THA revision. All were evaluated preoperatively and postoperatively based on the Harris Hip Score (HHS), the Western Ontario and McMaster Universities Index (WOMAC) score, and the visual analog scale for pain (VAS). Residual trochanteric pain and length discrepancies were recorded. Radiographic evaluation included signs of osteolysis, subsidence, loosening, and heterotopic ossification.ResultsPCS survivorship was 100% at 5 years and 95.9% at 10 years. Overall, significant postoperative improvements (P < .01) were observed on the HHS (44.3 vs 86.9), WOMAC (42.8 vs 82.8), and VAS (7.0 vs 3.0). Postoperative scores on all scales were higher for Group 1 (P < .01). Three patients (4.1%) underwent further stem revision. Demarcation lines (1 mm) were found in 12 (16.2%) patients and significant heterotopic ossifications in 22 (29.7%).ConclusionThe use of PCS for stem revision in failed THA with a limited femoral bone defect is a reliable option for both isolated stem revision and concomitant cup revision in well-selected patients. 相似文献
7.
Myung-Sik Park Ju-Hong Lee Jong-Hyuk Park Dong-Hun Ham Yang-Keun Rhee 《The Journal of arthroplasty》2010
Most reports on the use of modular femoral stems during revision surgery have involved short follow-up periods. The authors evaluated the clinical and radiographic performance of 59 patients fitted with a distal fix modular stem. The average follow-up period was 8.2 years. Average Harris hip score was improved from 47 to 87.6. Of 19 patients with trochanteric osteotomy, 4 had a displaced greater trochanter. Re-revision was performed in 5 patients, and 3 of these were for subsidence (of these 3, subsidence was associated with dissociation of the coupling part in 1 and with osteotomy nonunion in other 2 [proximal component only]). Modular distally fixed femoral stems were found to offer intraoperative flexibility, but to suffer from subsidence and intraoperative greater trochanter and metaphyseal femoral fractures. 相似文献
8.
Harpal S. Khanuja Kimona IssaQais Naziri MD Samik BanerjeeRonald E. Delanois MD Michael A. Mont MD 《The Journal of arthroplasty》2014
Nineteen patients (nineteen hips) who had undergone revision total hip arthroplasties using a proximally-coated primary cementless stem were evaluated to determine if a subset of revision arthroplasty patients could be identified where the use of this stem would be appropriate. Of these 19 revisions, 15 were performed for the second stage treatment of infection. The femoral bone deficiency was classified as Paprosky Type I in 6 hips and Type II in 13 hips. At a mean follow-up of 49 months, aseptic stem survivorship was 95% with one revision due to aseptic stem failure. The mean Harris hip scores had improved from a mean of 44 points pre-operatively to 89 points post-operatively. Intra-operatively, there was one complication which included a peri-prosthetic fracture distal to the stem which was treated with an allograft strut with cerclage wires. The authors believe that in type I or II femoral defects, the use of this specific cementless stem may be beneficial in the setting of a revision total hip arthroplasty. 相似文献
9.
《The Journal of arthroplasty》2020,35(12):3697-3702
BackgroundThe use of an extensively porous-coated uncemented cobalt-chrome monoblock femoral stem for revision total hip arthroplasty (THA) is well established with excellent mid-term results. The aim of this study is to report the long-term survivorship of these implants in femoral stem revisions.MethodsThis is a long-term retrospective review of prospectively collected data of 55 femoral stem revisions in 55 patients using a contemporary, cementless extensively porous-coated cobalt-chrome monoblock stem. All patients between 2001 and 2006 who underwent first time femoral stem revision with a contemporary, cementless extensively porous-coated cobalt-chrome monoblock stem were included. Harris Hip Score, Western Ontario and McMaster Universities Index, and University of California Los Angeles activity scores were recorded preoperatively and at latest follow-up. Radiographs were analyzed for evidence of loosening, subsidence, osteolysis, and bony union. This study included 55 patients, comprising of 36 females (66%) and 19 males (34%) with a mean age of 66.4 ± 9.3 years at the time of surgery. The mean time interval from index procedure was 9.8 ± 2.9 years. Mean time from revision THA to final follow-up was 13.2 ± 2.17 years with a minimum of 10 years of follow-up.ResultsIndications for revision included aseptic loosening (33), prosthetic joint infection (13), and periprosthetic fracture (10). Significant improvement in Harris Hip Score (85.1 ± 1.77 vs 51.8 ± 2.3, P < .001), Western Ontario and McMaster Universities Index (17.6 ± 0.77 vs 33.3 ± 0.8, P < .001), and University of California Los Angeles (5.25 ± 0.2 vs 2.7 ± 0.36, P < .001) scores were found at latest follow-up compared to preoperative. Fifty-four patients (98%) achieved stable bony ingrowth on radiographic analysis. All 10 patients treated for periprosthetic fractures achieved bony union of their fractures. Two patients suffered intraoperative periprosthetic fractures and were treated with a cable-plating system. There were no mechanical failures and no femoral stem re-revisions. One patient was diagnosed with a deep infection and was treated with chronic suppressive antibiotic therapy due to significant medical comorbidities.ConclusionRevision of the femoral component with a contemporary extensively porous-coated cobalt-chrome femoral stem has excellent functional outcomes, radiographic outcomes, and long-term survivorship with minimal complications. 相似文献
10.
《The Journal of arthroplasty》2023,38(5):903-908
BackgroundAs the number of primary total hip arthroplasty (THA) cases increase, so does the demand for revision operations. However, long-term follow-up data for revision THA is lacking.MethodsA retrospective review was completed of patients who underwent revision THA at a single institution between January 2002 and October 2007 using a cementless modular stem. Patient demographic, clinical, and radiographic data was collected. Preoperative and postoperative patient-reported outcome scores were compared at a minimum of fourteen-year follow-up.ResultsEighty-four patients (89 hips) with a median age of 69 years (range, 28 to 88) at operation were included. Indications for revision included aseptic loosening (84.2%), infection (12.4%), and periprosthetic fracture (3.4%). Twenty-two hips sustained at least 1 complication: intraoperative fracture (7.9%), dislocation (6.7%), prosthetic joint infection (4.5%), deep venous thrombosis (3.4%), and late periprosthetic fracture (2.2%). There were no modular junction complications. Eight patients underwent reoperations; only three involved the stem. Thirty-eight patients (45%) were deceased prior to final follow-up without known reoperations. Twenty-seven patients (32%) were lost to follow-up. Twenty-one patients (23%) were alive at minimum fourteen-year follow-up. Complete patient-reported outcomes were available for nineteen patients (range, 14 to 18.5 years of follow-up). Significant improvement was seen in UCLA activity, VR-12 physical, hip disability and osteoarthritis outcome score, joint replacement., and Harris Hip score pain and function scores.ConclusionChallenges of long-term follow-up include patient migration, an unwillingness to travel for re-examination, medical comorbidities, advanced age, and death. The cementless modular revision stem demonstrated long-term clinical success and remains a safe and reliable option for complex revision operations. 相似文献
11.
Kyoung Ho Moon Joon Soon Kang Sang Hyup Lee Sae Rom Jung 《Clinics in Orthopedic Surgery》2009,1(2):105-109
Background
To determine the benefit of an extensively porous coated femoral stem in patients receiving revision total hip arthroplasty.Methods
This study reviewed the results of 35 patients who received a revision total hip arthroplasty with extensively porous coated femoral stem between August, 1996, and December, 2002. The mean follow-up period was 77.5 months. The clinical and radiological results were evaluated by the Harris hip score and serial roentgenographic findings.Results
The preoperative and postoperative Harris hip score was 68.3 and 92.5, respectively. Radiographically, none of the acetabular components showed any evidence of migration, tilt, rotation, or shedding of metal particles. In addition, none of the femoral components showed evidence of subsidence, pedestal, or shedding of metal particles. Twenty-two hips had a mild stress shield and 2 hips had a moderate stress shield. The perioperative complications encountered were deep vein thrombosis (1 case), mild heterotopic ossification (4 cases), intraoperative periprosthetic fractures (1 case), and nonunion of the trochanteric osteotomy site (2 cases).Conclusions
Extensively porous coated femoral stems and acetabular components produce excellent clinical and radiological results in revision total hip arthroplasty. 相似文献12.
Jin-Ho Cho Jonathan P. Garino Suk-Kyu Choo Kye-Young Han Jung-Hoon Kim Hyoung-Keun Oh 《Clinics in Orthopedic Surgery》2010,2(4):214-220
Background
Aseptic loosening of cemented hip prostheses is recognized as a long-term problem, and especially in males and younger patients. Much energy has been focused on developing new prostheses that are designed for cementless fixation. We evaluated the performance of and periprosthetic bone response to a tapered, titanium, hydroxyapatite (HA)-coated femoral hip prosthesis at a minimum of 7 years of follow-up after treatment with primary total hip arthroplasty.Methods
Seventy-eight patients and 86 hips were included in the study. There were 35 men and 43 women; the mean age at the time of the operation was 59 years (range, 41 to 81 years). We used a tapered, titanium (Ti6Al4V), HA-coated femoral implant. We evaluated the patients at a minimum of 7 years of follow-up after treatment with primary total hip arthroplasty. Clinical evaluation was performed using the scoring system and the hip scores were assigned according to the level of pain, the functional status and the range of motion. The patients who refused to return, but who did forward X-rays for review after being contacted were questioned by phone about the functional status of their hip. Radiographic follow-up was performed at six weeks, at three, six and twelve months and yearly thereafter. All the available radiographs were collected and assessed for implant stability, subsidence, osseointegration, osteolysis, stress shielding and evidence of periprosthetic lucency.Results
Eighty-six hips (78 patients) were available for review at follow-up of greater than 7 years. In 11 of the 86 cases, acetabular failure required revision of the acetabular component, but the femoral stem survived and it was available for long-term evaluation. The radiographs were obtained at 7-year follow-up for another 20 hips, but the patients would not come in for the 7-year clinical evaluation. Therefore, a phone interview was conducted to assess any change in the functional status at a minimum of 7 years.Conclusions
The mechanical fixation of a tapered, titanium, HA-coated femoral implant was excellent in this study. This femoral design provided reliable osseointegration that was durable at a mean of 7 years follow-up. 相似文献13.
14.
《The Journal of arthroplasty》2022,37(2):303-311
BackgroundAs indications for elective total hip arthroplasty (THA) expand to younger patients, we sought to (1) compare revision risk following primary elective THA in patients <55 years at the time of their THA to patients aged ≥65 years and (2) identify specific risk factors for revision in patients <55 years.MethodsA Kaiser Permanente's total joint replacement registry was used to conduct a cohort study including primary elective THA patients aged ≥18 (2001-2018). In total, 11,671 patients <55 years and 53,106 patients ≥65 years were included. Multiple Cox regression was used to evaluate cause-specific revision risk, including septic revision, aseptic loosening, instability, and periprosthetic fracture. Stepwise Cox regression was used to identify patient and surgical factors associated with cause-specific revision in patients <55 years.ResultsPatients <55 years had a higher risk of septic revision (hazard ratio [HR] = 1.30, 95% confidence interval [CI] = 1.02-1.66), aseptic loosening (HR = 2.60, 95% CI = 1.99-3.40), and instability (HR = 1.35, 95% CI = 1.09-1.68), but a lower risk of revision for periprosthetic fracture (HR = 0.36, 95% CI = 0.22-0.59) compared to patients aged ≥65 years. In the <55 age group, risk factors for septic revision included higher body mass index, drug abuse, and liver disease. Hypertension, anterior approach, and ceramic-on-ceramic were associated with aseptic loosening. White race, American Society of Anesthesiologists classification ≥3, smoker, paralysis, posterior approach, ceramic-on-ceramic, and smaller head diameter were associated with instability.ConclusionIdentified risk factors varied depending on the cause for revision. Although septic revisions were related to patient characteristics, more modifiable factors, such as implant or surgical approach, were associated with revision due to aseptic loosening and instability.Level of EvidenceIII. 相似文献
15.
《The Journal of arthroplasty》2023,38(5):880-885
BackgroundThe purpose of the present study was to update and report clinical outcomes and survival of primary total hip arthroplasty using a cementless double-tapered titanium fully hydroxyapatite-coated stem at a follow-up > 30 years.MethodsThe outcomes of this series of 347 primary total hip arthroplasties were already published at a follow-up > 25 years, during which only 12 stems were revised. Since then, there were two additional stem revisions, bringing the total to 14 stem revisions (all of which also required cup revision). Patients still living with the original stem were assessed using the modified Harris Hip Score and patient satisfaction (very satisfied, satisfied, dissatisfied, and very dissatisfied). Revision incidence was calculated using the Kaplan-Meier (KM) method and Cumulative Incidence Function (CIF) at 35 years.ResultsAt a mean follow-up of 33 years (range, 31 to 35 years), 32 patients (34 hips) were still living with the original stem. Their mean modified Harris Hip Score was 86 points (range, 46 to 100) and all patients (100%) were very satisfied or satisfied with surgery. The revision incidence at 35 years considering (a) stem revision for any reason was 9.5% using KM and 4.5% using CIF; (b) stem revision for aseptic loosening was 3.1% using KM and 2.1% using CIF; and (c) reoperation or revision of any component for any reason was 45.3% using KM and 26.3% using CIF.ConclusionThe present study has demonstrated excellent survival at 35 years for a cementless double-tapered titanium fully hydroxyapatite-coated stem.Level of EvidenceLevel IV, Retrospective cohort study. 相似文献
16.
Hiroshi Ito Hiromasa Tanino Yasuhiro Yamanaka Toshiki Nakamura Akio Minami Takeo Matsuno 《The Journal of arthroplasty》2011,26(2):236-243
We evaluated intermediate-term to long-term survival of cemented calcar replacement femoral components in hybrid revision total hip arthroplasty. We followed up 52 hips in 50 patients for a mean of 11.4 years. Six (12%) femoral components had been revised: 2 for aseptic loosening, 2 for periprosthetic fracture, and 2 for deep infection. One additional femoral component was definitely loose. The number of previous revision operations (P = .004), preoperatively poorer femoral bone stock (P = .005), and postoperative poor cement mantle grading (P = .003) were significant factors for failure. Kaplan-Meier analysis revealed that the 15-year survival rate was 90% with mechanical failure as the end point. This technique remains a reasonable option for the first-time revision, especially for older and less active patients. 相似文献
17.
《The Journal of arthroplasty》2023,38(4):751-756
BackgroundRecent studies indicate a decreased risk of periprosthetic femoral fractures (PFFs) in cementless total hip arthroplasty (THA) for short compared to straight stems. However, the results are still inconclusive. Therefore, we retrospectively investigated the rate of PFFs within the first year between cementless short and straight stem THA.MethodsA 1:1 propensity score matching of 3,053 THAs was performed. Two groups including 1,147 short stem THAs implanted through a minimally invasive antero-lateral approach and 1,147 straight stem THAs implanted through a transgluteal Hardinge approach were matched. The rates of PFFs and fracture patterns were compared between both stem types. Risk factors for PFFs were analyzed by multivariate regression analyses.ResultsThe overall rate of PFFs was 1.7% in short stem THA and 3.2% in straight stem THA (P = .015). Postoperatively detected Vancouver A fractures occurred significantly more often in straight stem THA (P = .002), while the occurrence Vancouver B fractures did not differ significantly (P = .563). The risk of PFFs was significantly increased for women in straight stem THA (Odds ratio (OR) 2.620; Confidence Interval (CI) 1.172-5.856; P = .019). Increasing age showed a significantly increased odds ratio in short stem (OR 1.103; CI 1.041-1.169, P < .001) and straight stem THA (OR 1.057; CI 1.014-1.101, P = .008).ConclusionShort stem THA reduces Vancouver Type A PFFs in the trochanteric region compared to straight stem THA, while Vancouver Type B fractures are comparable. Increasing age is a significant risk factor for both stem types, while the risk for PFFs in women was only significantly increased in the straight stem group. 相似文献
18.
Yoshihide Nakamura Hiromasa Mitsui Akira Kikuchi Satoshi Toh Hiroshi Katano 《The Journal of arthroplasty》2011,26(1):77-81
We performed total hip arthroplasty using an anatomic medullary locking cementless stem for small-physique patients from 1988 to 1995. We conducted a retrospective study of 50 joints in 44 cases, including 40 developmentally dysplastic hips followed for 12 to 20 years (average, 15.1 years). Average height and body weight were 152 cm and 56 kg (5.0 ft and 124 lb), respectively, with an average body mass index of 24.2. Twelve joints (24%) were revised for acetabular-sided failures. Forty-eight stems (96%) showed bone ingrowth fixation, and there were no unstable stems. The simple cylindrical shape of the distal portion of the AML stem was less affected by deformity of the proximal femur of developmental dysplasia of the hip in patients with a small physique, and both clinically and radiologically good results were confirmed at long-term follow-up. 相似文献
19.
Sureshan Sivananthan Chin-Tat Lim Rapeepat Narkbunnam Alex Sox-Harris James I. Huddleston Stuart B. Goodman 《The Journal of arthroplasty》2017,32(4):1245-1249
Background
Modular femoral stem provides flexibility in femoral reconstruction, ensuring improved “fit and fill”. However, there are risks of junction failure and corrosion, as well as cost concerns in the use of modular femoral stems.Methods
We reviewed prospectively-gathered clinical and radiographic data on revision total hip arthroplasties (THAs) performed from 2001-2007 using modular, cementless femoral component performed by the 2 senior authors. Patients with a minimum follow-up of 7 years were included in this study.Results
Sixty-four patients (68 hips) with a median age of 68 ± 14 years (range 40-92 years) at revision THA were included. The median follow-up was 11.0 ± 1.8 years (range 7-14). Harris hip score, femoral stem subsidence, and stem osseointegration were recorded. The Harris hip score improved from an average of 38.1-80.1 (P < .01). Five hips had one or more dislocations. Seven patients underwent reoperations, 3 of which did not involve the stem. Four stems required revision because of infection, recurrent dislocation, or suboptimal implant position. Survival rates for any reasons and revision for femoral stems were 90% and 94%, respectively, at the most recent follow-up. Four stems subsided more than 5 mm, but established stable osseointegration thereafter. Seven nonloose stems (10.2%) demonstrated radiolucent lines in Gruen zones 1 and 7. No complications regarding the modular junction were encountered.Conclusion
Modular, cementless, extensively porous-coated femoral components have demonstrated intermediate-term clinical and radiographic success. Initial distal intramedullary fixation ensures stability, and proximal modularity further maximizes fit and fill. 相似文献20.
Tatsuya Tamaki Kurato Jonishi Yoko Miura Kazuhiro Oinuma Hideaki Shiratsuchi 《The Journal of arthroplasty》2018,33(3):805-809