首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《The Journal of arthroplasty》2022,37(9):1839-1843
BackgroundBoth cones or sleeves have been developed to address metaphyseal bone loss in revision total knee arthroplasty (TKA), but few studies have directly compared the outcomes. The purpose of this study was to compare the survivorship and aseptic revision rates between metaphyseal cones and sleeves at intermediate follow-up.MethodsWe reviewed a consecutive series of 1,172 revision TKA patients between 2009 and 2018 with a minimum two-year follow-up on all patients. We compared demographics, surgical indication, stem fixation, constraint, rates of rerevision, and Short-Form-12 scores between patients with cones and sleeves. A multivariate analysis was performed to identify the effect of cones and sleeves on aseptic rerevision. Kaplan-Meier curves were generated to compare aseptic survivorship of cones and sleeves.ResultsThere were 194 tibial cones (17%), 107 tibial sleeves (9%), 31 femoral cones (3%), and 135 femoral sleeves (12%) with a mean follow-up of 6.5 years (range: 2-12 years). There was no difference in demographics, indication, stem fixation, or constraint (P > .05). Although overall aseptic failure rates may be lower for tibial sleeves, there were no significant differences in survivorship over a one-year, two-year, and five-year follow-up when both tibial and femoral sleeves were directly compared to cones.ConclusionBoth tibial and femoral sleeves and cones perform well at an intermediate-term follow-up. Further investigation of these two are required to better understand their survivorship relative to each other.  相似文献   

2.

Background

Metaphyseal fixation has promising early results in providing component stability and fixation in revision total knee arthroplasty (TKA). However, there are limited studies on midterm results of metaphyseal sleeves. We analyzed complications, rerevisions, and survivorship free of revision for aseptic loosening of metaphyseal sleeves in revision TKA.

Methods

Two hundred eighty patients with 393 metaphyseal sleeves (144 femoral, 249 tibial) implanted during revision TKA from 2006-2014 were reviewed. Sleeves were most commonly cemented (55% femoral, 72% tibial). Mean follow-up was 3 years, mean age was 66 years, and mean body mass index was 34 kg/m2. Indications for revision TKA included 2-stage reimplantation for deep infection (37%), aseptic loosening of the tibia (14%), femur (12%), or both components (9%), and instability (14%).

Results

There was a 12% rate of perioperative complications, most commonly intraoperative fracture (6.5%). Eight sleeves (2.5%) required removal: 6 (2%) during component resection for deep infection (all were well-fixed at removal) as well as 1 (0.8%) femoral sleeve and 1 (0.8%) tibial sleeve for aseptic loosening. Five-year survivorship free of revision for aseptic loosening was 96% and 99.5% for femoral and tibial sleeves, respectively. Level of constraint, bone loss, sleeve and/or stem fixation, and revision indication did not significantly affect outcomes.

Conclusion

Metaphyseal sleeve fixation to enhance component stability during revision TKA has a 5-year survivorship free of revision for aseptic loosening of 96% and 99.5% in femoral and tibial sleeves, respectively. Both cemented and cementless sleeve fixation provides reliable durability at intermediate follow-up.  相似文献   

3.

Background

Porous metaphyseal cones are widely used in revision knee arthroplasty. A new system of porous titanium metaphyseal cones has been designed based on the femoral and tibial morphology derived from a computed tomography–based anatomical database. The purpose of this study is to evaluate the initial mechanical stability of the new porous titanium revision cone system by measuring the micromotion under physiologic loading compared with a widely-used existing porous tantalum metaphyseal cone system.

Methods

The new cones were designed to precisely fit the femoral and tibial anatomy, and 3D printing technology was used to manufacture these porous titanium cones. The stability of the new titanium cones and the widely-used tantalum cones were compared under physiologic loading conditions in bench top test model.

Results

The stability of the new titanium cones was either equivalent or better than the tantalum cones. The new titanium femoral cone construct had significantly less micromotion compared with the traditional femoral cone construct in 5 of the 12 directions measured (P < .05), whereas no statistical difference was found in 7 directions. The new porous titanium metaphyseal tibial cones demonstrated less micromotion in medial varus/valgus (P = .004) and posterior compressive micromotion (P = .002) compared with the traditional porous tantalum system.

Conclusion

The findings of this biomechanical study demonstrate satisfactory mechanical stability of an anatomical-based porous titanium metaphyseal cone system for femoral and tibial bone loss as measured by micromotion under physiologic loading. The new cone design, in combination with instrumentation that facilitates surgical efficiency, is encouraging. Long-term clinical follow-up is warranted.  相似文献   

4.
《The Journal of arthroplasty》2020,35(6):1591-1594.e3
BackgroundRecently, the use of short tibial stems in the obese population undergoing total knee arthroplasty (TKA) has been proposed. Thus, we designed a study to assess tibial component survivorship after primary TKA using a single implant both with and without a fully cemented stem extension performed by a single surgeon.MethodsA search of our institutional research database was performed. A minimum 2-year follow-up was selected. Cohorts were created according to patient body mass index (BMI; >40 kg/m2 and <40 kg/m2) and the presence (stemmed tibia [ST]) or absence (non-stemmed tibia [NST]) of a short tibial stem extension. Kaplan-Meier survival analyses for aseptic loosening and log-rank tests were performed.ResultsA total of 236 patients were identified (ST = 162, NST = 74). Baseline patient characteristics were statistically similar between cohorts with the exception of BMI which was greater in the ST cohort (32.9 kg/m2, 30.6 kg/m2; P = .01). Kaplan-Meier survival analysis at 5 years was superior for the BMI < 40 kg/m2 cohort (98.9%, 93.1%; P = .045), the ST cohort (100%, 94.5%; P = .006), and the BMI > 40 kg/m2 with ST cohort at 4 years (71.4%, 100%; P = .008).ConclusionMorbid obesity and a short native tibial stem design appear to be associated with aseptic loosening in primary TKA. This appears to be mitigated through the use of an ST. As such, the use of ST may be considered in at-risk patients. Alternatively, implants with longer native stem designs can be employed. Modern short-stemmed tibial components may need to be redesigned.  相似文献   

5.
Twenty-nine porous tantalum metaphyseal cones were implanted in 21 patients (14 women and 7 men) during revision TKA. The average age at the time of the procedure was 73.3 years. Sixteen revisions were considered aseptic and 5 were reimplantations after sepsis. Eight patients had stemmed revision implants and thirteen primary designs. According to the Anderson Orthopaedic Research Institute bone defect classification, femoral defects were rated as F3 in 14 knees and F2B in 3 knees. Tibial defects were rated as T2A in 3 cases, T2B in 3 cases and T3 in 5 cases. A femoral cone was inserted in 10 patients, a double cone (femur and tibia) in 8, and a single tibial cone in 3. A rotating hinge knee prosthesis (RHK, Zimmer) was inserted in 10 patients and a constrained condylar prosthesis (LCCK, Zimmer) in 11 patients. The diaphysis was cemented in 9 cases and, in 11 cases, just the metaphysis. At an average follow up of 36 months only one reconstruction was removed due to persistent infection. All metaphyseal cones showed evidence of stable osseointegration. According to the Knee Society Score the results were rated as excellent in 12 cases, good in 5 cases, fair in 3 and poor in 1 case. In the short term, porous tantalum metaphyseal cones provided structural support for large femoral and tibial defects. They also provided the environment for bone graft osseointegration, repair of femoral fractures and effective interdigitation of cement mantle into the trabecular metal cone.  相似文献   

6.
BackgroundThe purpose of this study was to compare the functional outcomes and implant survivorship at a minimum of 5 years of follow-up of several reconstruction techniques with or without metaphyseal cone and stems of variable length.MethodsA retrospective comparative matched analysis was performed from 2 prospectively collected databases. Only patients who underwent revision total knee arthroplasty procedures for aseptic causes using a single design of rotating hinge knee with a minimum of 5 years of follow-up were analyzed. Patients were separated into 3 groups: trabecular metal (TM) cones + short cemented stems (TM + short stem [SS]), TM cones + long uncemented stems (TM + long stem [LS]), and no cone (NC) + long uncemented stems (NC + LS). A matching process based on age (±5 years) was realized.ResultsAbout 99 patients were included; 33 in the TM + SS group, 33 in the TM + LS group, and 33 in the NC + LS group. The mean time of follow-up was 9.3 years. A significant difference of the improvement of subscale pain, symptom, activities of daily living, quality of life of the Knee Injury and Osteoarthritis Outcome score and knee, function of the Knee Society Score was observed in favor of TM + SS group compared with the 2 other groups. At 8 years of survivorship, the components free of revision for any cause were 90.9% for the TM + SS group, 84.9% for the TM + LS group, and 90.6% for the NC + LS group.ConclusionThe use of a short cemented tibial stem combined with a TM cone in revision total knee arthroplasty offers identical survival rate with better functional outcome compared with the use of a long uncemented stem associated with TM cones or metallic augments at a minimum of 5 years of follow-up.  相似文献   

7.
BackgroundAddressing bone loss and securing implant fixation can be challenging in revision total knee arthroplasty (TKA). We present the results of a large series of revision TKAs using a metaphyseal sleeve.MethodsWe retrospectively analyzed 319 revision TKAs with the use of a metaphyseal sleeve that had been followed up for at least 2 years, using a prospectively collected database. The mean follow-up was 91 months, and 73 patients were followed up for more than 10 years.ResultsImplant survivorship was 99.1% at 3 years, 98.7% at 5 years, and 97.8% at 10 years. No metaphyseal sleeve was revised for aseptic loosening. Final radiographic review showed that there were radiolucent lines present in 2.8% of tibial sleeves and 2.7% of femoral sleeves; none of these had progressed and none were revised. About 3.7% of tibial sleeves subsided more than 1 mm compared with the immediate postoperative X-ray but all stabilized and none were revised.ConclusionUse of a metaphyseal sleeve in revision TKA is associated with excellent survivorship and radiographic outcome in the medium to long term.  相似文献   

8.
BackgroundModular tibial stem extensions in total knee arthroplasty (TKA) are designed to reduce the risk of aseptic loosening of the tibial base plate. However, these implants add significant cost and an evaluation of their effectiveness in reducing this risk of loosening has not been studied in a large cohort. We sought to evaluate modular tibial stem utilization in primary TKA.MethodsWe conducted a cohort study using our integrated healthcare system’s Total Joint Replacement Registry. Patients who underwent cemented primary TKA were identified (2009-2019). Propensity scores were used to 1:1 match patients without to those with a stem extension. Cox proportional-hazards regression was used to evaluate the risk for revision due to aseptic loosening.ResultsTen thousand four hundred seventy six TKA with a modular tibial stem were matched to 10,476 TKA without a tibial stem. Stem utilization associated with a lower risk of revision for loosening across all postoperative follow-up (hazard ratio = 0.38, 95% confidence interval = 0.17-0.85).ConclusionIn a matched cohort study, we observed presence of a stem extension was associated with a lower risk of revision for aseptic loosening. Further study to identify specific risk factors for aseptic loosening and confirm the findings presented here are warranted.Level of EvidenceLevel III.  相似文献   

9.
Revision arthroplasty of large tibial defects remains a challenge. Thirty revision knee arthroplasties using a porous titanium tibial sleeve for Anderson Orthopaedic Research Institute (AORI) Type 2B and Type 3 defects with minimum 2 year follow up were retrospectively reviewed. The average Knee Society Score increased from 55 pre-operatively to 92 post-operatively. Six patients had a repeat operation though none were sleeve related. All radiographs at final follow-up showed well fixed components with osseous in-growth. Seven patients had end-of-stem pain, four of which resolved. Our short-term results show that porous titanium sleeves are a promising option when managing large areas of metaphyseal bone loss by filling defects and providing stable construct with biologic fixation.  相似文献   

10.
《The Journal of arthroplasty》2021,36(10):3543-3550
BackgroundWe aimed to evaluate the outcomes of hybrid fixation technique in condylar revision total knee arthroplasty (rTKA) using cementless metaphyseal tibial sleeves and short-cemented femoral stems with a rotating platform articulation.MethodsRetrospective consecutive study of all condylar rTKAs with a cemented femoral stem between 2009 and 2016 was conducted. Patients were identified using a local prospective database and linkable data obtained from the National Joint Registry for rTKA. Demographic, clinical, and surgical data were collected from patients’ electronic health records. The primary outcome measure was mechanical failure and implant survivorship using a nationally collected data, complications, re-operations, and “any-cause revision” were also recorded.ResultsThere were 72 consecutive patients (72 knees) with minimum 5-year follow-up: 33 (45.8%) females and 39 (54.2%) males with a median age of 70 years (range 47-88). The indication for revision surgery was aseptic loosening (n = 34, 47.2%), instability (n = 17, 23.6%), infection (n = 14, 19.5%) with 10 patients having 2-stage approach and 4 patients with single-stage approach, stiffness (n = 4, 5.6%), and malalignment (n = 3, 4.1%). At mean follow-up of 6.87 years (median 6.7; range 5-11.8), only 2 patients required revision for infection. Using “any-cause implant revision” as an end point, implant survivorship for this construct was 97.2% at median 6.7 years. To date, none of the femoral stems have been revised for mechanical failure.ConclusionIn rTKA with good femoral condylar bone stock, we have shown excellent survivorship with a short-cemented femoral stem, in conjunction with a mobile-bearing and a tibial sleeve. This has the advantage of reducing the length of the revision construct of this complex surgery.Level of EvidenceLevel IV.  相似文献   

11.

Background

Bone loss is a severe problem in septic revision total knee arthroplasty (RTKA). The use of porous coated metaphyseal sleeves is a promising treatment option for metaphyseal bone defects. The currently published midterm results remain limited and no study has been focused exclusively on septic cases. Our aim was to determine the implant survivorship (with special focus on osseointegration) and the clinical and radiological midterm outcome of metaphyseal sleeve fixation in septic RTKA surgery (minimum follow-up of 2 years).

Methods

We performed a clinical and radiographic examination of 56 patients with a history of prosthetic joint infection who underwent 2-stage RTKA with the use of porous coated metaphyseal sleeves. These examinations included evaluation of the American Knee Society Score, the Western Ontario and McMaster Universities Osteoarthritis Index, the Short Form (SF-36) Health survey as well as radiographic measurement to determine whether successful osseointegration had been achieved.

Results

Nine patients (16%) had to be re-revised at the time of follow-up (mean, 5.3 years; range, 2-11.2), all due to reinfection. We did not encounter any cases of aseptic loosening. The mean range of motion (92°, SD ± 21°), subjective satisfaction score (7, SD ± 2), American Knee Society Score (76, SD ± 19), Western Ontario and McMaster Universities Osteoarthritis Index (70, SD ± 20), SF-36 mental component summary (55, SD ± 14), and SF-36 physical component summary (35, SD ± 9) have shown satisfying results.

Conclusion

Metaphyseal sleeves have shown very promising midterm results regarding clinical scores, osseointegration, and aseptic loosening. Our results are the first analyzing exclusively septic indications and indicate that they are a reliable fixation option in all bone defect types in septic RTKA patients.  相似文献   

12.
BackgroundFixation options for revision total knee arthroplasty (rTKA) have expanded and now include cementless metaphyseal fixation. The utilization rates of these implants in the United States are not well known. The purpose of this study was to analyze trends in cementless metaphyseal fixation for rTKA within the American Joint Replacement Registry (AJRR).MethodsThe AJRR was queried for the years 2015-2019 to identify all rTKA with implant data. Trends in the use of cementless sleeves, metaphyseal cones, and any cementless metaphyseal fixation (sleeves + cones) were examined over the study period using logistic regression analysis.ResultsTwenty thousand two hundred and eighty rTKA were analyzed. Cementless metaphyseal fixation was used in 16% of rTKA and significantly increased over the study period (14% to 19%, P < .0001). Cementless metaphyseal fixation was more frequently utilized during revision for aseptic loosening than other diagnoses (OR 1.014, 95% CI 1.001-1.027). Cementless sleeve utilization decreased over time (11% to 9%, P = .004), driven by decreased use on the femur (4% to 2%, P < .0001). The use of cones increased significantly over time (3% to 9%, P < .0001), driven by increased use on the tibia (2% to 9%, P < .0001). Cones were 22 times more likely to be utilized on the tibia relative to the femur (P < .0001) and were more likely to be used in revisions for infection (OR 1.103, 95% CI 1.089-1.117) and aseptic loosening (OR 1.764, 95% CI 1.728-1.800).ConclusionCementless metaphyseal fixation has grown in popularity yet, still comprised only 16% of rTKA over a 5-year period. Most of the increase was due to the utilization of tibial metaphyseal cones.  相似文献   

13.
Stepped porous titanium metaphyseal sleeves may provide an option for enhanced fixation in managing challenging tibial defects in revision total knee arthroplasty (TKA). We retrospectively reviewed data on 51 patients who underwent revision TKA utilizing a metaphyseal sleeve for Anderson Orthopaedic Research Institute (AORI) Type II and III tibial defects between June 2007 and July 2011. Of these 51 patients, 36 patients had complete clinical and radiographic data. At final follow-up (mean: 38 months) significant improvements in knee range of motion and Knee Society scores were observed postoperatively (P < 0.001). Four revision procedures were necessary, but none for aseptic implant fixation failure. Radiographic review at final follow-up revealed stable, osteointegrated components without component migration or clinically significant osteolysis. Metaphyseal sleeve use in the management of moderate to severe tibial defects in revision TKA resulted in satisfactory clinical outcomes and is a versatile option for achieving stable fixation.  相似文献   

14.
BackgroundRecent case series have reported early failure with the use of high-viscosity cement (HVC) in total knee arthroplasty (TKA). We evaluated revision risk after TKA with HVC compared with medium-viscosity cement (MVC) in a large cohort.MethodsWe conducted a cohort study using data from Kaiser Permanente’s Total Joint Replacement Registry. Patients who underwent fully cemented primary TKA for osteoarthritis were identified (2001-2018). Only posterior-stabilized, fixed-mobility designs of the 3 highest-volume implant systems (DePuy PFC, Zimmer NexGen, and Zimmer Persona) were included to mitigate confounding from implant characteristics. Palacos (Zimmer/Heraeus) and Simplex (Stryker) cements comprised the HVC and MVC exposure groups, respectively. Propensity score–weighted Cox proportional hazards regression was used to evaluate risk for any revision during follow-up and risk for revision from aseptic loosening specifically.ResultsThe final cohort comprised 76,052 TKAs, 41.1% using MVC. The crude 14-year cumulative revision probability was 4.55% and 5.12% for TKA with MVC and HVC, respectively. In propensity score–weighted Cox models, MVC compared with HVC had a lower risk of any revision (hazard ratio = 0.82, 95% confidence interval = 0.70-0.95) while no difference was observed for revision from aseptic loosening (hazard ratio = 0.80, 95% confidence interval = 0.56-1.13).ConclusionWhile we observed a lower risk for any revision with the use of Simplex MVC compared with Palacos HVC, we did not observe a difference in revision for aseptic loosening specifically. Given the widespread use of HVC, additional research to investigate other HVC and potential mechanisms for failure outside of loosening is warranted.Level of EvidenceLevel III.  相似文献   

15.
BackgroundRevision of both femoral and tibial components of a total knee arthroplasty (TKA) for aseptic loosening has favorable outcomes. Revision of only one loose component with retention of others has shorter operative time and lower cost; however, implant survivorship and clinical outcomes of these different operations are unclear.MethodsBetween January 2009 and December 2019, a consecutive cohort of revision TKA was reviewed. Univariate and multivariable analyses were used to study correlations among factors and surgical related complications, time to prosthesis failure, and functional outcomes (University of California Los Angeles, Knee Society functional, knee osteoarthritis and outcome score for joint replacement, Veterans RAND 12 (VR-12) physical, and VR-12 mental).ResultsA total of 238 patients underwent revision TKA for aseptic loosening. The mean follow-up time was 61 months (range 25 to 152). Ten of the 105 patients (9.5%) who underwent full revision (both femoral and tibial components) and 18 of the 133 (13.5%) who underwent isolated revision had subsequent prosthesis failure [Hazard ratio (HR) 0.67, P = .343]. The factor analysis of type of revision (full or isolated revision) did not demonstrate a significant difference between groups in terms of complications, implant failures, and times to failure. Metallosis was related to early time to failure [Hazard ratio 10.11, P < .001] and iliotibial band release was associated with more complications (Odds ratio 9.87, P = .027). Preoperative symptoms of instability were associated with the worst improvement in University of California Los Angeles score. Higher American Society of Anesthesiologists status and higher Charlson Comorbidity Index were related with worse VR-12 physical (?30.5, P = .008) and knee osteoarthritis and outcome score for joint replacement (?4.2, P = .050) scores, respectively.ConclusionIsolated and full component revision TKA for aseptic loosening does not differ with respect to prosthesis failures, complications, and clinical results at 5 years. Poor American Society of Anesthesiologists status, increased comorbidities, instability, and a severe bone defect are related to worse functional improvement.Level of evidenceIII, cohort with control.  相似文献   

16.

Background

Short-term stability after revision total knee arthroplasty (TKA) with either fully cemented or hybrid-placed implants is comparable. Interestingly, implant micromotion >1 mm/degree occurred with both techniques which might increase the risk of loosening in the midterm or long-term. Therefore, the present study investigated midterm stability and clinical results of fully cemented vs hybrid-placed revision TKA, with mild to moderate bone loss, using radiostereometric analysis (RSA).

Methods

This study involves the prolonged follow-up of a previous randomized controlled trial. RSA images taken at baseline, 6 weeks, 3 and 6 months, and 1, 2 and 6.5 years of follow-up were analyzed. Stability of the femoral and tibial implants was evaluated using total translation and rotation, based on the micromotion determined with model-based RSA.

Results

Of the 30 patients who completed the 2-year follow-up in the original randomized controlled trial, 23 (12 cement, 11 hybrid) were available for follow-up at 6.5-year (range 5.4-7.3). There were no differences in median total translation and rotation of the femoral and tibial components between the 2 groups, and none of the clinical scores differed between the groups. Interestingly, in the group with cemented stems, 5 tibia implants showed >1 mm/degree micromotion compared to none in the hybrid group.

Conclusion

There was no difference in median micromotion and clinical outcome between fully cemented and hybrid-placed revision TKA 6.5 years postoperatively. Two femur components showed progressive migration over time whereas tibia components migrate especially in the first year followed by a stable situation. Whether this will lead to loosening and re-revisions remains to be investigated.  相似文献   

17.
Semi-constrained implants provide stability in the setting of soft-tissue deficiency in revision total knee arthroplasty (TKA). This study evaluated our institution’s long-term survival results with a semi-constrained implant used in the revision TKA setting. 234 semi-constrained revision total knee arthroplasties were performed in 209 patients. The average follow-up was 9 years. Forty repeat revisions were performed. 5-year survival was 91% and 10-year survival was 81%. Male gender significantly increased the risk of revision. At 10 years the average range of motion, pain level, and Knee Society score improved significantly (P < 0.001). Ninety percent of patients reported an improvement in their knee. The semi-constrained implant used in revision knee arthroplasty has acceptable implant survival and functional outcomes in the long-term follow-up period.  相似文献   

18.
BackgroundTwo-to 6-year results of reconstruction of severe bone defects in revision total knee arthroplasty (TKA) with highly porous tantalum cones have been encouraging, but 10-year follow-up is lacking. The purpose of this study was to determine the minimum 10-year results of tantalum cones in revision TKA.MethodsFrom 2005 to 2010, 30 consecutive patients (30 knees) underwent revision TKA with the use of cones. All patients were followed clinically and radiographically for a minimum of 10 years. A total of 42 cones (25 tibial and 17 femoral) were used to reconstruct massive bone defects classified as Anderson Orthopaedic Research Institute Types 2A (10), 2B (12), and 3 (19). The mean age of the patients was 73 years (range, 55 to 84) at the time of revision. The indication for the revision included aseptic loosening (15 patients) and second-stage reimplantation for deep infection (15 patients). Six patients were lost to follow-up.ResultsIn total, 6 cones had to be revised. Minimum 10-year cone survivorship for any reason was 81% (25 of 31 cones). With cone revision for aseptic loosening as the end point, survivorship was 96% (30 of 31). No evidence of loosening or migration of any implant was noted on the most recent radiographs.ConclusionMetaphyseal fixation with tantalum cones in revision TKA demonstrated excellent survivorship and fixation at a minimum follow-up of 10 years. This type of metaphyseal reconstruction can be a durable option for revision TKA in patients who have massive bone defects.  相似文献   

19.

Background

Femoral and tibial massive bone defects are common findings in septic total knee revision and pose considerable challenges for the orthopedic surgeon. The aim of this study was to report the midterm clinical and radiographic outcomes with the use of tantalum cones for the management of massive bone defects after 2-stage knee revision.

Methods

We retrospectively reviewed the medical records of 60 patients (mean age, 67.9 ± 8.8 years) treated with 94 tantalum cones associated with constrained or semiconstrained knee for massive bone loss (mean follow-up, 43.5 ± 17.4 months). In all cases, the indication was a staged revision for periprosthetic knee infection. Functional scores, radiographic outcomes, and implant survivorship were analyzed.

Results

The mean Knee Society Score and Oxford Knee Score improved from 44.1 ± 7.4 and 19.2 ± 4.1 to 85.4 ± 5.6 and 38.4 ± 3.9 (P < .01), respectively. The mean flexion increased from 60.6° ± 15.5° to 96.8° ± 10.9° at the last evaluation (P < .01). The mean improvement in flexion contracture was 6.2 ± 8.0 (P < .01). Two failures (3.3%) due to periprosthetic knee infection recurrence were observed, but no cone-related mechanical failures were reported. The cone-related survival rate was 97.8%.

Conclusion

Excellent clinical and radiographic midterm outcomes were achieved with a low complication rate. Tantalum cones may be considered a safe and effective option in the management of massive bone defects also in septic knee revision surgery.  相似文献   

20.
《The Journal of arthroplasty》2022,37(10):2025-2034
BackgroundLoosening remains one of the most common reasons for revision total knee arthroplasty (TKA). Cement viscosity has a potential role in reducing revision rates for loosening. The aim of this study was to assess the outcome for loosening of the 5 most used cemented knee prostheses by constraint type, based on the cement viscosity type used.MethodsThere were 214,708 TKA procedures performed between 1999 and 2020 for a diagnosis of osteoarthritis using the 5 most commonly used minimally stabilized, posterior stabilized, and medial pivot design cemented tibial components. Only procedures with a cemented tibial component were included. Outcomes for two different cement viscosities, 140,060 high viscosity and 74,648 low viscosity cement, were compared for each fixation type within each of the three stability groups.ResultsThere was no difference in a risk of all-cause revision when high viscosity cement was used compared to low viscosity cement for minimally stabilized prostheses (hazards ratio [HR] 1.07 [95% CI 0.99-1.15], P = .09), posterior stabilized prostheses (HR 1.03 [95% CI 0.95-1.11], P = .53), and medial pivot design prostheses (HR 1.06 [95% CI 0.80-1.41], P = .67). No difference was observed between cement viscosity types for any of the prosthesis constraint types when aseptic loosening was assessed.ConclusionsWe found no difference in the risk of revision for any reason, or for loosening, with cement viscosity for the most commonly used minimally stabilized, posterior stabilized, and medial pivot TKA. The role of cement viscosity in the risk of TKA revision remains unclear and further research is required.Level of EvidenceLevel III Retrospective comparative study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏