1.
运用低杆温微波电极扩大肝脏消融范围的实验研究   总被引:5,自引:0,他引:5  
目的:改进微波消融技术以扩大肝组织凝固范围,为临床改善局部疗效提供实验依据。方法:采用一种新型的水冷式低杆温微波电极对离体新鲜猪肝行微波消融,单次能量输出60~90W,5~25min,观察不同消融条件造成的组织凝固范围和形态。结果:单次能量输出造成的组织消融范围为(4.5~8.3)cm×(3.0~6.1)cm。单纯增加输出功率时,凝固灶以纵径增长为主,只有同时延长消融时间才可获得纵横径的显著增大,70~80W,25min最接近类圆形,是比较满意的消融条件。结论:加大微波的输出功率和延长消融时间可以显著扩大肝组织凝固范围,结合使用低杆温电极,临床治疗肝癌时可望改善局部疗效。  相似文献   

2.
多电极射频体外肝消融热场分布的实验研究   总被引:5,自引:0,他引:5  
目的探讨肝组织多电极射频的消融范围和热场分布情况.方法使用国产WE-7568射频消融仪和14G多电极射频针,对16块体外新鲜猪肝和牛肝组织消融,设置中心温度70°~80℃,持续10分钟,消融中测量电极针两旁4cm范围内的温度变化,随后观测肝组织凝固形态和范围.结果以电极针母针为中心6cm×6cm类圆形范围内平均温度可达50℃以上,4cm×3cm类圆形范围内可超过70℃,最高温度区在针尖前1cm,平均温度达99℃.消融凝固区为横椭圆形,猪肝凝固范围的平均大小5.1cm×3.9cm,牛肝的平均大小6.6cm×4.6cm,凝固体的中心位于针尖前0.5~1.0cm处.消融中升温速度快者凝固范围小,反之则大.结论使用本装置在体外肝可获得较大的组织凝固范围,最高温度区和凝固体中心点在针尖前方,消融中升温速度与凝固范围大小有关.  相似文献   

3.
目的研究不同功率时间组合下,微波凝固范围、形态及演变规律。方法微波功率60W、90W和凝固时间5min、15min依次组合,水循环冷却式微波天线凝固活体猪肝,超声仪实时观察凝固形态和范围。实验结束,所有凝固标本沿天线插入针道剖开,观察凝固区,范围指标为纵径、横径,形态指标为纵横径比、前纵径后纵径比。结果60W5min~经有较满意的凝固形态,15min时,形态稍退化。90W5min、15min均有较满意的凝固形态。结论当凝固范围直径为2cm左右时,可选择60W5min;当凝固范围直径为3cm左右时,可选择90W15min。  相似文献   

4.
目的 研究微波消融治疗在离体人肝组织的消融灶形态及范围.方法 通过在不同初始功率、作用时间下对离体人肝组织进行单针微波消融,超声及大体解剖观察消融灶的形态及范围,镜下观察消融灶病理学变化.结果 相同初始功率组消融灶随作用时间延长而增大;在相同作用时间下初始功率70 W组消融灶大于初始功率50 W组,其差异均有统计学意义(P<0.05).超声显示消融灶范围较大体解剖测量范围大,两者比较差异具有统计学意义(P<0.05).病理检查见消融灶中心凝固区肝组织均凝固坏死,距凝固区边缘0.5 cm处有1例可见残存水肿肝细胞、1 cm处有17例可见残存肝细胞组织.结论 微波消融灶呈椭圆形,其范围随初始功率及作用时间增加而扩大,超声测量比大体解剖消融范围大,消融灶与周围组织间有移行带.  相似文献   

5.
低杆温技术扩大肝组织微波消融范围的实验研究   总被引:1,自引:0,他引:1  
目的通过降低天线杆温来增加微波能量输出以扩大单次微波消融范围,减少穿刺次数,为改善临床局部疗效提供实验依据。方法采用水冷式低杆温微波天线对离体新鲜猪肝和活体猪肝进行单点微波消融,单源能量输出(60~80)W×(300~1500)s,双源能量输出70W×1200s,观察不同消融条件下肝组织凝固范围的大小。结果体外肝和活体肝内单源能量输出(80W×1500s)造成的组织消融范围分别为7.4cm×5.6cm和5.9cm×3.5cm,活体肝内双源消融灶大小为6.7cm×5.4cm。结论运用低杆温天线可加大能量输出,扩大了体外肝和活体肝组织的单点微波消融范围,可望改善临床微波消融治疗肝癌的局部疗效。  相似文献   

6.
自制肝肿瘤微波治疗仪的实验研究和临床试用   总被引:18,自引:1,他引:17  
目的 采用自制肝肿瘤微波治疗仪在超声导向下对肝组织进行微波辐射的实验研究和微波治疗肝癌的临床试用。方法 选择离体新鲜猪肝、健康动物 (猪、犬 )及 2例肝癌患者 ,在超声导向下对肝脏及肿瘤植入微波天线 ,以不同功率、不同时间作用于肝组织和肝肿瘤 ,解剖实验动物 ,观察声像变化规律。结果 离体肝及活体动物肝 ,在微波功率 2 0~ 70W ,作用时间 60~ 3 60s ,逐次搭配作用形成凝固性坏死灶 ,大小范围为 8mm× 5mm× 4mm~ 3 6mm× 2 9mm× 2 4mm ,形态呈椭球形。微波作用区中心温度 10 8℃ ,边缘温度 ( 5 0± 5 )℃。2例肝癌患者微波治疗获得成功。结论 微波辐射选用条件以 60W、180s为好 ,所形成的凝固区范围与国内外报道相似 ,证明自行研制的肝肿瘤微波治疗仪是成功的。 2例肝癌患者的微波治疗取得满意效果。  相似文献   

7.
超声引导下微波介入治疗大肝癌的实验研究及临床应用   总被引:10,自引:1,他引:9  
目的进一步探讨超声引导下微波治疗大肝癌的可行性和疗效。方法采用分次多点多部位由深到浅低功率长时间分段微波凝固,对10个65斤重的猪肝和2只狗进行了实验研究;60例大肝癌患者进行了超声引导下微波治疗。结果微波治疗后两个或多个坏死区叠加,凝固坏死区加大。离体猪肝坏死区达到6cm×6cm,狗肝坏死区为5cm×6cm。所有病例治疗后肿块缩小,肿瘤内血流消失或减少;22例CT检查,肿块缩小,18例无强化;28例超声引导下活检大片坏死。治疗后全身情况好转,AFP和肝功能改善,生活质量提高。无严重并发症发生。随访3~28个月,51例存活。结论实验研究表明改进微波治疗方法,坏死区加大,超声引导微波治疗大肝癌也有较好的疗效。  相似文献   

8.
目的:探讨水循环微波热疗治疗肝癌的近期疗效及安全性。方法:用FORSEA MTC-3微波热疗仪治疗肝癌60例.通过血清甲胎蛋白(AFP)水平,影像学检查等指标观察疗效。结果:18例AFP升高的肝细胞癌患者,微波治疗后AFP均恢复至或接近正常值一治疗后肿瘤区增强CT扫描各期均无强化,以PV期最明显,而周边可见很薄的环形强化.治疗的坏死范围要大于治疗前病灶范围,微波热疗的范围不仅覆盖整个肿瘤,包括肿瘤周边的一部分正常肝组织.单点穿刺可获得5.5cm×4.5cm×4cm的有效热疗区;2点穿刺可获得7.5cm×5.5cm×5.5cm的有效热疗区:3点穿刺可获得9.5cm×9cm×9cm的有效热疗区。结论:改良的微波热疗安全有效,能够扩大组织坏死范围.[著者文摘]  相似文献   

9.
目的探讨肝静脉主干旁肿瘤经皮微波凝固治疗的可行性。方法新鲜离体猪肝20只,10只制成模拟肝静脉循环模型,10只作为对照组,在超声引导下以60W/5min对肝静脉主干旁肝组织进行植入式微波凝固,分别观测、比较凝固区的大小、形态,观察肝静脉主干的受损状况。结果微波凝固后,声像图清晰显示实验组肝静脉,管径(5.46±0.19)mm,流速(31.68±1.95)cm/s,与凝固前无差异(P>0.05)。肉眼观,实验组的凝固区形态失去对称性,在微波天线与肝静脉之间的凝固范围随两者距离缩短而变小。肝静脉管壁无明显受损。结论肝静脉主干具有对抗微波凝固性能,肝静脉主干旁经皮微波凝固安全、可行。  相似文献   

10.
目的探讨灰阶超声造影在肝外伤微波凝固治疗中的应用价值。方法开腹状态下建立猪II级肝外伤伴活动性出血模型32处,微波凝固治疗功率分别采用70W和80W,时间5min。分别于治疗前、后应用常规超声及灰阶超声造影观察肝内损伤区的变化。结果常规超声难以显示肝外伤后所致的活动性出血。灰阶超声造影由于能清晰显示损伤区内的活动性出血,可实时引导将微波电极准确放置在肝内活动性出血部位。微波凝固治疗后,70W、80W两组治疗区呈长径分别为[(4.61±0.39)cm,(4.71±0.57)cm](t=-0.48,P>0.05)、短径分别为[(3.03±0.60)cm,(2.77±0.41)cm](t=1.14,P>0.05)的近似椭圆形无回声区,其中心部除针道呈极亮的强回声外均未见增强,呈负性显影;而56.2%(9/16)的70W治疗区和37.5%(6/16)的80W治疗区周边部可见少许线状增强。病理学证实,微波治疗区中心部汇管区的血管呈不同程度的退变坏死,肝细胞退变坏死,而周边部以肝细胞退变坏死为主要表现,血管坏死不明显。结论灰阶超声造影可用于实时引导微波电极的置入和术后疗效的判断,在肝外伤微波凝固治疗中具有一定的应用价值。  相似文献   

11.
CT引导下经皮穿刺肝囊肿及肾囊肿硬化剂治疗的疗效分析   总被引:1,自引:0,他引:1  
目的探讨CT引导下经皮肝囊肿、肾囊肿硬化剂治疗的临床应用价值。方法51例(肝脏囊肿20例,肾脏囊肿31例)经CT扫描确诊为单纯性囊肿的患者,囊肿大小自2.8cm×3.5cm×5.3cm~9.8cm×15.6cm×16.8cm不等。在CT导向下应用穿刺抽吸针抽出囊液,并注射硬化剂无水乙醇治疗,硬化剂注射量约为抽出囊液的25%。术后分别于3个月及半年后各复查一次CT扫描。结果51例肝脏囊肿及肾脏囊肿均一次穿刺成功,有效率为100%。半年后复查见49例完全消失或明显缩小,2例有缓慢复发迹象。51例中,46例于术后3个月复查一次,且中33例于术后半年复查第二次,另外5例于半年后复查1次,均未见复发。结论CT引导下经皮肝囊肿及/或肾囊肿硬化剂治疗有较高临床应用价值,且方便、安全有效。  相似文献   

12.
Ablation catheters with multiple long coiled electrodes have been recently developed to induce continuous linear lesions for the treatment of atrial fibrillation. The efficacy and safety of ablation catheters with multiple long coiled electrodes has not been evaluated. The aim of the present in vivo study was to investigate the influence of saline irrigation on lesion dimensions and coagulum formation during RF current ablation using those ablation catheters. In 14 anesthetized sheep, the thigh muscle was prepared as a cradle and filled with heparinized blood (37 degrees C). The quadripolar coiled ablation catheter (electrode length 7 mm, electrode distance 2 mm) was placed parallel to the muscle with standardized 10-g contact pressure. RF current energy was delivered sequentially temperature-(70 degrees C) or power-controlled (10, 20, 30, or 40 W) with additional irrigation of the electrode (10 mL/min normal saline) for 90 seconds. Forty-two of 129 RF current lesions were induced by temperature-controlled and 87 by irrigated ablation. Except for three lesions following low energy irrigated application (10 W), all lesions were continuous. Significantly larger lesions following irrigated RF current applications were produced with a power output of 30 W (depth 0.74 +/- 0.13 cm, width 0.78 +/- 0.13 cm) and 40 W (depth 0.75 +/- 0.16 cm, width 0.92 +/- 0.28 cm) as compared to 20 W (depth 0.47 +/- 0.13 cm, width 0.82 +/- 0.22 cm). Coagulum formation adherent to the electrode was exclusively observed following 18 of 42 nonirrigated RF current ablations. In conclusion, irrigated coiled ablation electrodes induce continuous linear lesions with a power output of 20-40 W. The risk of coagulum formation at the coiled electrode can be avoided by irrigation.  相似文献   

13.
外周性原始神经外胚层肿瘤的影像学表现   总被引:2,自引:0,他引:2  
目的探讨外周性原始神经外胚层肿瘤(pPNETs)的影像学表现,以提高对本病的认识。方法回顾性分析15例pPNETs的临床及影像学资料,其中软组织pPNETs6例,骨pPNETs9例;7例行X线检查,12例行CT检查,9例行MRI检查。结果骨pPNETsX线及CT平扫表现为范围较广泛、边缘模糊的溶骨性骨质破坏,周围均见大小不等软组织肿块影,大小为2.5cm×2.8cm~10cm×13cm,平均6.2cm×7.4cm;6例病灶增强扫描后见肿块强化,但强化多不均匀。软组织pPNETsCT平扫肿瘤密度不均匀,实质部分为等密度,内可见不同程度的坏死、囊变区;肿瘤大小2.7cm×4.8cm~12.4cm×14.5cm,平均6.7cm×8.2cm;增强扫描后均呈不均匀强化。MRI示病灶T1WI呈等信号6例,等-低混杂信号1例,中等稍高信号2例;T2WI均呈不规则中、高信号;8例钆喷替酸葡甲胺(Gd-DTPA)增强后均表现为不均匀强化。结论pPNETs多表现为溶骨性骨质破坏和(或)巨大软组织肿块,其内常见不同程度的坏死、囊变。CT、MR能较好显示肿瘤的内部结构、明确肿瘤的范围,有助于本病的诊断及鉴别诊断;对判定手术的可切除性、检出远处转移及评价治疗效果等具有较大的价值。  相似文献   

14.
二维超声对海洛因依赖者的睾丸、附睾观察   总被引:1,自引:0,他引:1  
目的了解海洛因依赖者睾丸、附睾的超声表现.方法应用Aloka SSD-1100实时超声诊断仪,探头频率为变频5~7.5MHz.对81例海洛因依赖者睾丸、附睾进行B超观测.结果左、右睾丸平均大小分别为3.90cm×1.90cm、3.89cm×1.85cm;左、右附睾平均大小为1.33cm×1.02cm、1.21cm×0.94cm.睾丸回声不均匀者5人,均匀者76人;附睾回声不均匀者75人,均匀者6人;其中附睾囊肿22人.结论海洛因依赖者附睾回声多有改变,睾丸无明显异常.  相似文献   

15.
目的本文提出一种利用聚焦超声的声致发光,结合ICCD成像技术检测不同组织成像差异的方法.方法实验样品为一块4 cm×4 cm×2 cm的猪的脂肪组织,中间埋入一块0.5 cm×0.5 cm×0.5 cm的血块,代表不同的组织层,利用聚焦超声对组织内的一层进行逐点扫描,然后对各点在超声作用下产生的发光强度进行二维图像重建,利用各点发光强度的差异得到组织样品的二维图像.结果利用该方法能够清晰地得到脂肪组织中埋藏血块的二维分布,测量精度达到0.5 mm,测量深度达到1 cm.结论该方法可望在乳腺癌等皮下肿瘤的早期诊断中得到应用.  相似文献   

16.
平阳霉素碘油乳剂治疗肝血管瘤的临床应用价值   总被引:11,自引:1,他引:11  
目的 评价和探讨平阳霉素碘油乳剂 (PLE)治疗肝血管瘤的临床应用和疗效。方法 治疗肝血管瘤 12例 ,瘤体最小 3 .3cm× 3 .0cm ,最大 12 .0cm× 13 .0cm ,采用Seldinger技术股动脉插管 ,将导管超选择至肿瘤供血动脉插管后 ,注入平阳霉素碘油乳剂 ,并用明胶海绵颗粒栓塞供血动脉。术后定期复查。结果 介入治疗栓塞后碘油沉积良好 ,所有瘤体均有不同程度缩小 ,术后无严重并发症发生。结论 平阳霉素碘油乳剂治疗肝血管瘤安全、有效 ,并发症少 ,可成为治疗肝血管瘤的重要手段。  相似文献   

17.
胸主动脉假性动脉瘤的MRI诊断   总被引:4,自引:0,他引:4  
目的 评价MRI对胸主动脉假性动脉瘤的诊断价值,方法,对16例假性动脉瘤患者行心电图门控MRI扫描,结果 本组假性动脉瘤均位于主动脉轮廓之外,瘤体较大(2.8cm*3.2cm*4.0cm-4.3cm*5.6cm*10.0cm),偏于一侧,境界清楚,形状不规则,其中不多数(13例)瘤体内部可与血流信号相同的小瘤腔(0.1cm*0.6cm*0.8cm-0.3cm*2.0cm*3.0cm),瘤壁较厚,信号呈不均匀层状,在SE图像上为中等信号或中等度高信号,在GRE电影图像上为较低信号,可见裂隙状破口以及经破口向瘤腔内喷射的血液信号;3例无瘤腔者MRI未显示破口,瘤体信号与有瘤腔者相同。结论 MRI可显示假性动脉瘤的特异性征象,是假性动脉瘤影像学论断方法之一。  相似文献   

18.
目的 观察新型腔内射频消融导管对离体猪肝(肝实质、栓子模型)的消融效果。方法 应用EMcision Habib腔内射频消融导管及RITA射频发生器对新鲜离体猪肝肝实质及栓子模型进行消融,输出功率分别为5 W、10 W、15 W和20 W,消融时间分别为60 s、90 s和120 s,观察消融灶组织凝固形态及范围。结果 消融肝实质时,输出功率为10 W、延长消融时间(90 s延长至120 s),输出功率为15 W、延长消融时间(60 s延长至90 s)以及消融时间为60 s和90 s、增加输出功率(15 W增加至20 W)获得的消融灶长径增加(P均<0.05),而宽径增加不明显(P均>0.05)。消融栓子模型时,输出功率为10 W、延长消融时间(90 s延长至120 s),以及消融时间为60 s、增加输出功率(15 W增加至20 W)均可增加消融灶长径(P均<0.05),而宽径增加不明显(P均>0.05)。肉眼见所有消融灶附着处血管管壁颜色均与邻近血管管壁无差异。结论 采用EMcision Habib腔内射频导管消融离体猪肝可出现明确的消融范围,且对管道壁无明显损伤。  相似文献   