共查询到20条相似文献,搜索用时 31 毫秒
1.
Purpose
The purpose of this study was to retrospectively compare and review the clinical outcomes between the distal clavicular locking plate and clavicular hook plates in the treatment of unstable distal clavicle fractures; moreover, the relevant literature of the two fixation methods was reviewed systematically to identify the non-union, complications, or functional scores, according to the treatment methods and determine which treatment method is better.Methods
Sixty-six patients with 66 unstable distal clavicle fractures who underwent open reduction and internal fixation with either a distal clavicular locking plate (36 patients) or a clavicular hook plate (30 patients ) were evaluated. The main outcome comparisons included Constant score, rate of non-union, rate of complication, and rate of returning to work three months postoperatively.Results
No significant difference was found between locking plate and hook plate groups in union rate and Constant score (P > 0.05). However, the results indicated that the distal clavicular locking plate group had a significantly lower rate of complications (P < 0.05) and symptomatic hardware (P < 0.05). In addition, the distal clavicular locking plate facilitated the return to work better than the clavicular hook plate (P < 0.05).Conclusions
Both distal clavicular locking plate and clavicular hook plate achieved good results in the treatment of unstable distal clavicle fractures; however, internal fixation with a distal clavicular locking plate had greater ability to return to their previous work after surgery in three months and fewer complications than the clavicular hook plate. 相似文献2.
Purpose
Displaced type 2 lateral end clavicle fractures have a tendency to delayed union or non-union. Various methods of stabilisation of the displaced lateral end fractures are described. The increasing use of implants to fix such fractures also necessitates extensive dissection for implant retrieval. Adequate reduction and minimal tissue trauma during implant placement and removal would be ideal modalities for fixation of such fractures.Methods
All displaced type 2 lateral end clavicle fractures fulfilling our inclusion criteria were reduced with a small anterosuperior incision. Anteroposterior drill holes were made in both the fragments and a nonabsorabable polyester suture was passed through. The fracture was reduced and fixed with transacromial smooth Kirshner wires. The suture was tied with the knot superiorly in a figure-eight manner. The arm was supported in an arm pouch for six weeks. The Kirshner wire was routinely removed after six weeks in an out-patient department. Clinico-radiological outcome was studied at six weeks, and monthly intervals thereafter until union.Results
All 16 fractures united. The mean average age of patients was 36.25 years with a SD of 11.35. There was no loss of reduction even after removal of Kirshner wires at six weeks. The mean average time of union was 10.75 weeks with a SD of 3.92. All patients regained near normal range of motion, and the mean average constant score at the end of one year was 98.37 with a SD of 2.87. All patients returned to preinjury level by the one-year follow-up. The range of motion remained the same in those who were followed up in successive years. Skin impingement with bent Kirshner wires were noted in four cases. Kirshner wires backed out in one case before six weeks but there was no loss of reduction. Infection and Kirshner wire breakage were not noted in our series.Conclusion
The clinico-radiological outcomes with our modified tension band fixation for displaced type 2 lateral end clavicle fractures were encouraging and comparable with earlier studies. 相似文献3.
Yongchuan Li Xi Jiang Qinghe Guo Lei Zhu Tianwen Ye Aimin Chen 《International orthopaedics》2014,38(6):1261-1267
Purpose
A few studies focused on the methods of treatment for displaced distal tibial shaft fractures have been published, all of which compared two different methods. In this randomized, prospective study, we aimed to compare minimally invasive plate osteosynthesis, locking intramedullary nail stabilization and external fixation combined with limited open reduction and absorbable internal fixation for distal tibial shaft fractures by assessing complications and secondary procedures.Methods
From November 2002 to June 2012, 137 skeletally mature patients with displaced distal tibial shaft fractures with or without fibula fracture were randomized to be treated by minimally invasive plate osteosynthesis (group A, n = 46), locking intramedullary nail (group B, n = 46) or external fixation combined with limited open reduction and absorbable internal fixation (group C, n = 45). Age, gender, mechanism of injury, fracture pattern and presence of open fracture were equally distributed among the three groups. Indexes for evaluation included hospital stay, operative time, time to radiographic union, union status, infection and the incidence of re-operation. Mazur ankle score was introduced for functional evaluation. Statistics Analysis System (SAS) 9.2 was used for analysis.Results
A total of 121 patients were included in the final analysis (group A 42, group B 40 and group C 39) and evaluated after a mean of 14.8 months follow-up. There was no significant difference (P > 0.05) in hospital stay, time to radiographic union and the incidence of union status among the three groups. Although group C was associated with less secondary procedures versus groups A and B, it was related with more pin tract infections (15.4 %). Anterior knee pain occurred frequently after locking intramedullary nailing (37.5 %) and the irritation symptoms were more frequently encountered in group A (59.5 %). There was no difference in ankle function between the three methods after operation (P > 0.05).Conclusions
We consider that the minimally invasive plate osteosynthesis, locking intramedullary nail stabilization and external fixation combined with limited open reduction and absorbable internal fixation techniques are all efficient methods for treating distal tibia fractures. With its wide indications, external fixation combined with limited open reduction and absorbable internal fixation leads to minimal soft tissue complication, good functional result and no local soft tissue irritation or implant removal. 相似文献4.
Chul-Hyun Cho Kwang-Soon Song Byung-Woo Min Ki-Cheor Bae Kyung-Jae Lee 《Clinics in Orthopedic Surgery》2010,2(3):154-159
Background
To compare the outcomes of reconstruction plate and reconstruction locking compression plate (LCP) for the treatment of clavicle midshaft fractures.Methods
Forty one patients with a clavicle midshaft fracture were treated by internal fixation with a reconstruction plate (19 patients) or reconstruction LCP (22 patients). The clinical and radiological results were evaluated according to the Quick Disability of the Arm, Shoulder, and Hand (DASH) score and plain radiographs.Results
The mean time to union was 14.6 weeks in the reconstruction plate group compared to 13.2 weeks in the reconstruction LCP group (p > 0.05). The mean score to Quick DASH was 33.85 points in the reconstruction plate group compared to 34.81 points in the reconstruction LCP group (p > 0.05). The complications in the reconstruction plate were hypertrophic scarring in 2 cases, painful shoulder in 2 cases, limitation of shoulder motion in 2 cases, and screw loosening in 3 cases. In addition, the complications in the reconstruction LCP group was hypertrophic scarring in 4 cases, painful shoulder in 1 case and a limitation of shoulder motion in 1case (p > 0.05).Conclusions
This study showed radiologically and clinically satisfactory results in both groups. Overall, operative treatment with a Reconstruction plate or reconstruction LCP for clavicle shaft fractures can be used to obtain stable fixation. 相似文献5.
Lars Eden Stefanie Doht S?nke P. Frey Dirk Ziegler Jan Stoyhe Kai Fehske Torsten Blunk Rainer H. Meffert 《International orthopaedics》2012,36(12):2537-2543
Purpose
The purpose of this study was to characterise the biomechanical properties of the seven hole superior anterior clavicle LCP (locking compression plate) and to compare these with the properties of commonly applied implants used for the stabilisation of clavicular midshaft fractures such as the locking 7- and ten hole reconstruction plate.Methods
Twenty-four synthetic clavicles were used. A transverse midshaft fracture was induced. The clavicles were fixed with angle stable clavicle LCPs, seven hole and ten hole reconstruction plates (n = 8 each). Twenty cycles of axial compression and torsion were performed for each sample, which was followed by 1,000 cycles of three point bending and ultimately bending to failure. Axial, torsional and cantilever bending stiffness were calculated from the data recorded.Results
The clavicle LCP showed the highest overall stiffness compared to the seven and ten hole reconstruction plate. Significantly higher stiffness values were found for axial compression and external rotation. In the load-to-failure tests, the ten hole reconstruction plate especially showed early signs of plastic deformation, which might account for early plate insufficiency so frequently observed clinically.Conclusion
The results indicate that the clavicle LCP, as compared to the reconstruction plates, leads to superior biomechanical stability in the treatment of midshaft clavicle fractures. 相似文献6.
7.
Paul T. P. W. Burgers Esther M. M. Van Lieshout Joost Verhelst Imro Dawson Piet A. R. de Rijcke 《International orthopaedics》2014,38(5):1045-1050
Purpose
Modern management of the elderly with a hip fracture is complex and costly. The aim of this study was to compare the treatment-related hospital length of stay (HLOS) before and after implementing a clinical pathway for patients undergoing hip fracture surgery.Methods
This was a retrospective, before-and-after study. The first period ranged from June 21, 2008 to November 1, 2009 (N = 212), and the second was from January 7, 2010 to July 7, 2011 (N = 314). The electronic hospital system and patients records were reviewed for demographics, HLOS, mortality, complications and readmissions.Results
In the first period 53 % had a femoral neck fracture, of which 57 % were treated with hemiarthroplasty. In the second period this was 46 % and 71 %. Pertrochanteric fractures were treated with a Gamma nail in 85 % in the first period, and in 92 % in the second period. The median HLOS decreased from nine to six days (p < 0.001). For the hemiarthroplasty group HLOS decreased from nine to seven days (p < 0.001); for internal fixation there was no significant difference (five versus six days, p = 0.557) and after Gamma nailing it decreased from ten to six days (p < 0.001). For mortality no statistically significant difference was found (6 % versus 5 %, p = 0.698). Complications decreased for the Gamma nail group (44 % versus 31 %, p = 0.049). Readmissions for the total group were not different (16 % versus 17 %, p = 0.720).Conclusions
Implementing a clinical pathway for hip fractures is a safe way to reduce the HLOS and it improves the quality of care. 相似文献8.
F. Wichlas N. P. Haas A. Disch D. Machó S. Tsitsilonis 《Journal of orthopaedics and traumatology》2014,15(4):259-264
Background
The aim of this study was to evaluate the complication rates of volar versus dorsal locking plates and postoperative reduction potential after distal radius fractures.Materials and methods
For this study 285 distal radius fractures (280 patients/59.4 % female) treated with locked plating were retrospectively evaluated. The mean age of the patients was 54.6 years (SD 17.4) and the mean follow-up was 33.2 months (SD 17.2). The palmar approach was used in 225 cases and the dorsal approach in 60 cases (95 % type C fractures).Results
Adequate reduction was achieved with both approaches, regardless of fracture severity. In the dorsal group, the complications and implant removal rates were significantly higher and the operative time was also longer.Conclusions
Based on these facts, we advocate the palmar locking plate for the vast majority of fractures. In cases of complex multifragmentary articular fractures where no compromise in reduction is acceptable, and with the biomechanical equality of palmar and dorsal plating remaining unproven, dorsal plating may still be considered.Level of evidence
Therapeutic level IV. 相似文献9.
Zu-Bin Zhou You-Shui Gao Ming-Jie Tang Yu-Qiang Sun Chang-Qing Zhang 《International orthopaedics》2012,36(11):2341-2345
Purpose
The aim of this study was to evaluate clinical outcomes and complications following minimally invasive plate osteosynthesis (MIPO) with the proximal humeral internal locking system (PHILOS) for treating proximal humeral shaft fracture through the deltopectoral approach.Methods
Between November 2008 and March 2010, 74 patients with unilateral proximal humeral shaft fractures were treated using the MIPO technique with the PHILOS through the deltopectoral approach. Patients received an average follow-up of 16.9 (range, 12–24) months, and the final follow-up included anteroposterior and lateral imaging and recording of postoperative complications. The Constant–Murley shoulder score was used to evaluate function.Results
No intraoperative complications occurred. Postoperative complications included subacromial impingement in four patients. There was no deep infection, neurovascular damage, breakage or implant loosening. All fractures united in an average time of 17.4 (15–25) weeks. In terms of function, the Constant–Murley score was 85.8 points on average (range, 67–100). The range of motion of the involved shoulder was satisfactory, and pain-free in 83.8 % of patients.Conclusions
Using the MIPO technique with the PHILOS through the deltopectoral approach is a valid and safe method of treating proximal humeral shaft fractures. 相似文献10.
John T. Capo Monika P. Debkowska Frank Liporace Bryan G. Beutel Eitan Melamed 《International orthopaedics》2014,38(5):1037-1043
Purpose
The locking compression extra-articular distal humerus plate (EADHP) is an anatomically shaped, angular stable single-column fixation system for distal third humerus fractures. The purpose of this retrospective study was to evaluate clinical and radiographic outcomes after open reduction and internal fixation of distal humerus fractures with this device.Methods
Twenty-one consecutive patients with distal humerus fractures were treated with the EADHP system between February 2006 and June 2012. Of these, 19 were clinically and radiographically evaluated after a mean follow-up of 10.4 months. Follow-up assessment included anteroposterior and lateral radiographs, assessment of range of motion (ROM), pain according to a visual analogue scale (VAS) and Disabilities of the Arm, Shoulder and Hand (DASH) score.Results
All fractures demonstrated satisfactory reduction and healing at an average of 7.3 months. One patient showed post-operative sensory ulnar neuropathy that recovered completely, and nine patients had a preoperative radial nerve palsy, which recovered spontaneously following exploration and plating. Mean post-operative ROM was as follows: flexion 126°, extension −7°, pronation 82° and supination 83°. The VAS score was zero points in eight patients, while the mean DASH score was 25.8 points.Conclusions
For extra-articular distal humerus fractures, including high-energy injuries often seen in gunshot wounds or motor vehicle injuries, the anatomically shaped angular stable single-column plate provides satisfactory clinical and radiographic results and serves as a valuable tool in the treatment of these injuries. 相似文献11.
Andres Anania Matthew P. Abdel Yuo-yu Lee Stephen Lyman Alejandro González Della Valle 《International orthopaedics》2013,37(10):1917-1923
Purpose
We investigated the incidence, natural history, and functional consequences of a newly developed flexion contracture after total knee arthroplasty (TKA).Methods
Forty patients with full knee extension preoperatively who developed a postoperative flexion contracture were match-paired 1:2 with 80 patients who had full extension. The incidence of a newly developed flexion contracture, ROM, and Knee Society scores (KSS) at six weeks, four months, and one year were analysed.Results
The incidence of a new flexion contracture at six weeks was 14 %, but diminished to 5 % and 0.3 % at four months and one year, respectively. One year after surgery, there was no difference in the KSS (p = 0.5).Conclusions
This study showed that the majority of patients who developed a new flexion contracture after TKA have full knee extension one year postoperatively. Moreover, knee extension and KSS at one year are equivalent to those patients who did not developed a flexion contracture. 相似文献12.
Purpose
This study evaluates two basic hypotheses: (1) the risk of an isolated dorsal approach to ventral lumbar spondylodiscitis based on clinical and radiographic results and (2) the risk of anterior radical debridement due to using a titanium implant in the site of bone infection.Methods
Group A consisting of 23 patients was treated only by a dorsal transmuscular approach and group B consisting of eight patients was treated by two-stage posteroanterior surgery. Both evaluated groups were assessed before surgery, six weeks and one year after surgery with the Japanese Orthopaedic Association (JOA) score, visual analogue scale (VAS) and Kirkaldy-Willis functional criteria. To evaluate the sagittal balance restoration, measurement by the Cobb modified angle of the affected segment was performed.Results
Differences (p < 0.001) in group A were found between JOA values before surgery (average 9.30) and at six weeks after surgery (average 11.82) and 12 months after surgery (13.27) and VAS differences before surgery (average 7.39), six weeks after surgery (average 3.82) and 12 months after surgery (average 2.36) in group A. According to the Kirkaldy-Willis functional criteria, 11 patients were evaluated as excellent, nine patients as good and two patients as poor. The values of the JOA score in group B showed an improvement compared with the JOA values before surgery (average 9.38) at six weeks after surgery (average 11.75) and 12 months after surgery (average 13.63), and the VAS score before surgery (average 7.38) was found to have improved six weeks after surgery (average 4.63) and 12 months after surgery (average 2.25). The functional evaluation according to the Kirkaldy-Willis functional criteria assessed three patients as excellent, four patients as good and one patient as fair. Radiographic examinations of group A revealed the following findings before surgery (average 1.75), six months after surgery (average −3.73) and 12 months after surgery (average −0.79) and in group B before surgery (average 3.71), six weeks after surgery (average −8.21) and 12 months after surgery (average −6.45).Conclusions
The results demonstrate the minimum serious surgical complications and greater loss of sagittal balance without clinical correlation in group A. We did not find any relapse or persistence of the infection in the post-operative period in group B. 相似文献13.
14.
Vasanth Sathiyakumar Rachel V. Thakore Rivka C. Ihejirika William T. Obremskey Manish K. Sethi 《International orthopaedics》2014,38(7):1483-1488
Purpose
We compared types of complications leading to re-operations in open and closed distal tibia fractures treated by locking or nonlocking medial plates.Methods
Ninety-three patients from 2002 to 2012 who underwent open reduction and internal fixation (ORIF) and medial plating for distal extra-articular or partial articular tibia fractures were identified. Charts were retrospectively reviewed to determine the incidence of re-operation based on the type of complication that developed. Fisher’s exact and chi-square tests were performed to analyze the incidence of complications based on injury and type of plate used.Results
Thirty-three (35.5 %) patients required re-operations: 28.6 % (n = 16) with closed injuries had complications leading to re-operations compared with 45.9 % (n = 17) of patients with open injuries (p = 0.12). Patients with closed injuries were more likely to require re-operation due to hardware pain/prominence (p = 0.03), whereas patients with open injuries were more likely to require re-operation due to nonunion (p = 0.04). There were no significant differences in infection (p = 0.66) or malunion (p = 0.99) between groups. Locking plates showed higher costs but were not associated with decreased risk of re-operation.Conclusions
There was a high re-operation rate associated with distal tibia medial plating, with significant differences in the reason for re-operation between open versus closed groups. Complication rates were not influenced by the use of locking plates. Results of this study suggest that methods be considered to reduce re-operation based on type of fracture, such as early bone grafting or the use of alternate implants for open fractures. 相似文献15.
Zettl R Müller T Topp T Lewan U Krüger A Kühne C Ruchholtz S 《International orthopaedics》2011,35(8):1245-1250
Objective
The development of locking plate systems has led to polyaxial screws and new plate designs. This study compares monoaxial head locking screws (PHILOS© by Synthes) and a new generation of polyaxial locking screws (NCB-LE© by Zimmer) with respect to biomechanical stability.Methods
On nine pairs of randomised formalin fixed humerus specimens, standardised osteotomies and osteosyntheses with nine monoaxial (group A) und nine polyaxial (group B) plate/screw systems were performed. A material testing machine by Instron (M-10 14961-DE) was used for cyclic stress tests and crash tests until defined breakup criteria as endpoints were reached.Results
After axial cyclic stress 200 times at 90 N, plastic deformation was 1.02 mm in group A and 1.25 mm in group B. After the next cycle using 180 N the additional deformation averaged 0.23 mm in group A and 0.39 mm in group B. The deformation using 450 N was 0.72 mm in group A compared to 0.92 mm in group B. The final full power test resulted in a deformation average of 0.49 mm in group A and 0.63 mm in group B after 2,000 cycles using 450 N. When reaching the breakup criteria the plastic deformation of the NCB plate was 9.04 mm on average. The PHILOS plate was similarly deformed by 9.00 mm.As a result of the crash test, in group A the screws pulled out of the humeral head four times whereas the shaft broke one time and another time the implant was ripped out. The gap was closed four times. In group B, there were three cases of screw cut-through, four shaft fractures/screw avulsions from the shaft and two cases of gap closure.Conclusion
The two systems resist the cyclic duration tests and the increasing force tests in a similar manner. The considerable clinical benefits of the polyaxial system are enhanced by equal biomechanical performance. 相似文献16.
17.
Sinan Zehir Murat Calbiyik Regayip Zehir Deniz Ipek 《International orthopaedics》2014,38(8):1655-1660
Purpose
This prospective randomized pilot study reports our institutional experience and early results using Sonoma Wrx (Sonoma Orthopedic Products, Santa Rosa, CA) in the treatment of extra-articular and simple intra-articular distal radius fractures.Material and methods
A total of 64 patients, were enrolled in the study. They were considered eligible if they had; unstable extra-articular distal radius fractures and simple intra-articular distal radius fractures suitable for closed reduction (AO types; A2.2, A2.3, A3.1 C2.1, C2.2). Patients in group I received intramedullary fixation using the Sonoma Wrx® device and patients in group II received standard volar locking plate fixation. Radiographic criteria of acceptable healing were used for evaluation.Results
Two groups were similar in terms of baseline characteristics. Mean time of operation was significantly shorter in Group 1 vs. in group 2 (36.81 ± 7.11 vs. 48.97 ± 5.9 minutes, p = 0.001). Time to healing of the fracture was not different between two groups (5.45 ± 1.09 vs. 5.70 ± 1.04 weeks for Group 1 vs. 2, respectively p = 0.36). Overall complications occurred in 9 patients in group 1 and in 15 patients in group 2 (p = 0.17). Follow-up was completed in all patients with a median time of 12 months and 13 months in group 1 and 2, respectively. On radiographic evaluation radial inclination, radial height and volar tilt were not significantly different between group 1 and 2, respectively. There were no significant differences between two groups in regard to wrist rotational degrees measured in last follow-up visit.Conclusion
Sonoma Wrx Device is reliable and effective in terms of achieving satisfactory outcomes in treatment of distal radius fractures. It may be reasonable to use this device to prevent complications that are related to extensive soft tissue dissection. 相似文献18.
19.
Purpose
The aim of this study was to determine the biomechanical characteristics of locking plates with the TriLock system with different design and screw settings compared to a non-locking plate in a diaphyseal metacarpal fracture.Methods
Oblique diaphyseal shaft fractures in porcine metacarpal bones were created in a biomechanical fracture model. After reduction they were fixed with three different locking plates with the TriLock interlocking mechanism or a non-locking linear plate in mono- or bicortical screw fixations. In load to failure tests the maximum load and stiffness were measured.Results
For linear plates, the maximum load was higher for the non-locking plate compared with the locking plate. The maximum load could be increased for the locking plates using a double-row design and a higher screw number. No differences were found for the stiffness between all groups. In contrast to the non-locking plate, the mode of failure of the locking plates in many cases (86 %) was a loss of the interlocking mechanism.Conclusions
The results suggest that the locking plates with the TriLock system achieve no higher stability compared to a non-locking plate in load to failure tests. Adaptions to increase the stability of the interlocking mechanism are desirable. 相似文献20.