首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We studied 13 patients with valvular vegetations who underwent intraoperative live/real time three‐dimensional transesophageal echocardiography (3DTEE) and real time two‐dimensional transesophageal echocardiography (2DTEE). The 3DTEE provided incremental value on top of 2DTEE in its ability to accurately identify and localize vegetations and in identifying complications of infective endocarditis such as abscesses, perforations, and ruptured chordae. By using 3DTEE, we were able to measure vegetation volumes, perforation areas, and estimate the area of the valve that is involved in the infective process. These preliminary results suggest the superiority of 3DTEE over 2DTEE in the evaluation of valvular vegetations and provide incremental knowledge that is useful to the cardiac surgeons. (ECHOCARDIOGRAPHY, Volume 26, November 2009)  相似文献   

2.
Detailed assessment of the tricuspid valve using two‐dimensional echocardiography is always challenging, as only two of three leaflets can be seen at a time. Three‐dimensional echocardiography can provide the enface view of the tricuspid valve that allows simultaneous visualization of all of the three leaflets. In a 42‐year‐old male patient scheduled for pulmonary endarterectomy, 3DTEE showed that the tricuspid valve is bileaflet, with one septal and another lateral leaflet. There were two commissures, one of them is anteriorly positioned and the other one is posterior. Our findings were confirmed intra‐operatively by direct surgical visualization of the tricuspid valve.  相似文献   

3.
Background: Carcinoid heart disease (CHD) is a rare cause of valvular heart disease and carries a poor prognosis. CHD has a unique morphology and echocardiographic features that predominantly involve right‐sided valvular structures. The diagnosis of CHD is usually made by two‐dimensional transthoracic echocardiography (TTE). With the superior spatial resolution of real time three‐dimensional transesophageal echocardiography (3DTEE), structural changes that occur in patients with CHD‐associated valvular heart disease can be examined in greater detail. We undertook this study to examine the incremental value of 3DTEE in the diagnosis of CHD. Methods: A total of four patients with CHD underwent TTE, transesophageal echocardiography (TEE), and 3DTEE as part of their routine clinical evaluation. Results: TTE and TEE for all four patients revealed thickened, fibrosed, retracted, and malcoapted tricuspid leaflets with wide‐open tricuspid valve regurgitation. 3DTEE en face imaging of the tricuspid valve demonstrated the characteristic morphologic features of CHD more clearly in all four patients. Conclusions: 3DTEE provides substantial incremental value over TTE in the assessment of characteristic CHD pathology and thus enhances the echocardiographic diagnosis of CHD. (Echocardiography 2010;27:1098‐1105)  相似文献   

4.
Twenty-nine patients with different tricuspid valve (TV) pathologies were studied by both two-dimensional transthoracic (2DTTE) and live/real time three-dimensional transthoracic echocardiography (3DTTE). A major contribution of 3DTTE over 2DTTE was the en face visualization of all three leaflets of the TV in all patients. This allowed accurate assessment of TV orifice area in patients with TV stenosis and carcinoid disease. Loss of TV leaflet tissue, defects in TV leaflets and size of TV systolic non-coaptation could also be delineated and resulted in identifying the mechanism of tricuspid regurgitation (TR) in patients with Ebstein's anomaly and rheumatic heart disease. Prolapse of TV leaflets could also be well visualized and enabled us to develop a schema for systematic assessment of individual segment prolapse which could help in surgical planning. The exact sites of chordae rupture in patients with flail TV as well as right ventricular papillary muscle rupture could be well seen by 3DTTE. 3DTTE also permitted sectioning of various TV masses for more specific diagnosis of their nature. In addition, color Doppler 3DTTE provided an estimate of quantitative evaluation of TR severity, since the exact shape and size of the vena contracta could be accurately assessed. In conclusion, our preliminary experience with 3DTTE has demonstrated substantial incremental value over 2DTTE in the assessment of various TV pathologies.  相似文献   

5.
Infective endocarditis (IE) affects patients at high clinical risk and may present as an acute and rapidly progressive, subacute or chronic infection. Transthoracic and transesophageal echocardiography represent the key diagnostic method in IE diagnosis. In particular, three‐dimensional transesophageal echocardiography represents the imaging technique that allows to establish with adequate accuracy dimensions, shape, and localization of endocarditis vegetations. In our case, we show a huge vermiform mycotic aneurysm in an immunodeficient young drug‐addicted man with severe mitral valve regurgitation and the additive value of three‐dimensional transesophageal echocardiography in this specific clinical setting.  相似文献   

6.
Tricuspid regurgitation (TR) produced by endocavitary leads (EL) from permanent pacemakers and implantable cardiac defibrillators is a well‐known complication of this procedure. The EL may damage or interfere with tricuspid valve function causing mechanical interference of the valve leaflets leading to incomplete valve closure. It is important to recognize this mechanical complication because it could be corrected by repositioning the lead. In this case report we demonstrate how three‐dimensional transthoracic echocardiography permits to obtaining an en face view, which allows simultaneous visualization of the 3 moving leaflets during the cardiac cycle, their attachment to the tricuspid annulus and the pattern of leaflet coaptation. Thus, we propose three‐dimensional transthoracic echocardiography as the tool of choice to evaluate TR related to EL, to evaluate the necessity of repositioning the lead if severe regurgitation or tricuspid valve malfunction are demonstrated.  相似文献   

7.
Purpose: Although nonobstructive prosthetic valve thrombosis (PVT) does not develop hemodynamic compromise, it carries potential risk for thromboembolism. Real time three‐dimensional transesophageal echocardiography (RT‐3DTEE), has emerged as a complementary tool in depicting “en face” views of prosthesis compared with two‐dimensional transesophageal echocardiography (2DTEE). We aimed to evaluate the utility of RT‐3DTEE in assessment of mitral ring‐located thrombosis. Method: We present 3 cases of mechanical mitral valve thrombosis complicated by thromboembolism, who were all examined and followed‐up by 2D transthoracic echocardiography (TTE), 2DTEE, and RT‐3DTEE. Result: The consequencies of thromboembolism in the patients were coronary embolism, transient ischemic attack, and ischemic stroke, respectively. They were all inadequately anticoagulated at the time of admission. 2DTTE and TEE examination was unsatisfactory; RT‐3DTEE depicted nonobstructive mitral ring thrombosis in each of the patients. The patients were followed up under effective anticoagulation and antiplatelet therapy. RT‐3DTEE was able to demonstrate the evolution of thrombus size in each of the patients. Conclusion: Nonobstructive ring‐located PVT which poses risk for thromboembolism, may be diagnosed with certainty and imaged with clarity utilizing RT‐3DTEE.  相似文献   

8.
Tricuspid valve endocarditis in a structurally normal heart of child is extremely rare and mysterious disease, which may mimic several other illnesses. We are reporting here a six-year-old child who presented with prolonged fever and unusual auscultatory sound of tumor plop, later proven to having tricuspid valve endocarditis by 2D echocardiography. The patient underwent surgical excision of the vegetations with repair of the tricuspid valve leaflets with successful outcome.  相似文献   

9.
In this retrospective study, we identified 7 cases where Lambl's excrescences were identified by two‐dimensional transesophageal echocardiography (2DTEE) and also had live/real time three‐dimensional transesophageal echocardiography (3DTEE) studies available for comparison. We subsequently assessed them for the presence of Lambl's excrescences (LE) and nodules of Arantius (NA) on the aortic valve. After their identification, we qualitatively and quantitatively organized our findings by number, cusp location, measurements, and orientation if applicable. A greater number of LE was found by 3DTEE than 2DTEE (19 vs. 11, respectively). In all 3DTEE studies, their cusp attachment site, their x‐, y‐, and z‐axis measurements, and orientation were clearly visualized and described. Only 3DTEE studies provided confident visualization of the cusp attachment sites. Similarly, a greater number of NA was found by 3DTEE than 2DTEE (21 vs. 5, respectively). The triad of NA was visualized in all 3DTEE studies and each was described using its x‐, y‐, and z‐ axis measurements. Only three 2DTEE studies provided reliable identification of the NA. In conclusion, we present further evidence of the incremental value of 3DTEE over 2DTEE in the qualitative and quantitative assessment of cardiac structures including LE and NA on the aortic valve.  相似文献   

10.
The mitral valve aneurysm is a rare complication of infective endocarditis involving mitral or aortic valve. The perforation of the mitral valve aneurysm can lead to significant mitral regurgitation (MR) or thromboembolism, which can cause sudden hemodynamic deterioration. We describe here a case of healed infective endocarditis of the aortic valve with ruptured mitral valve aneurysm that led to severe MR. The aneurysm of the anterior mitral leaflet was diagnosed by two‐dimensional transthoracic echocardiography. In this case, three‐dimensional transthoracic echocardiography demonstrated the detailed morphology of mitral valve aneurysm which resulted in successful surgical repair of the aneurysm.  相似文献   

11.
We report a case of an elderly patient in whom live/real time three-dimensional transesophageal echocardiography (3DTEE) provided definitive diagnosis of mitral-aortic intervalvular fibrosa abscess. This could not be done by two-dimensional transthoracic echocardiography (2DTTE) and two-dimensional transesophageal echocardiography (2DTEE). 3DTEE was also helpful in ruling out associated mitral valve endocarditis, which was initially suspected by 2DTEE leading to a mitral valve sparing surgery. Thus, 3DTEE provided incremental information over 2DTTE and 2DTEE in this patient.  相似文献   

12.
The right atrioventricular valve is formed by three leaflets as described by the classic anatomic studies. Two-dimensional transthoracic echocardiography (2DE) shows the tricuspid valve (TV) in its long axis. However, short-axis views of the TV leaflets are not generally obtained and therefore distinction between leaflets by 2DE is difficult. Real time three-dimensional echocardiography (RT3DE) overcomes this limitation of 2DE and facilitates obtaining short axis view (enface view) of the TV. In the current case study, en face view of the TV obtained by RT3DE was found to be formed of only two leaflets with two commissures. The surgical findings were consistent with that of RT3DE.  相似文献   

13.
We compared findings from intraoperative live/real time three-dimensional transesophageal echocardiography (3DTEE) and two-dimensional transesophageal echocardiography (2DTEE) with surgery in 67 patients having aortic aneurysm and/or aortic dissection. Of these, 20 patients had aortic aneurysm without dissection, 21 aortic aneurysm and dissection, and 26 aortic dissection without aneurysm. 3DTEE diagnosed the type and location of aneurysm correctly in all patients unlike 2DTEE, which missed an aneurysm in one case. There were four cases of aortic aneurysm rupture. Three of them were diagnosed by 3DTEE but only one by 2DTEE, and one missed by both techniques. The mouth of saccular aneurysm, site of aortic aneurysm rupture, and communication sites between perfusing and nonperfusing lumens of aortic dissection could be viewed en face only with 3DTEE, enabling comprehensive measurements of their area and dimensions as well as increasing the confidence level of their diagnosis. In all patients with aortic dissection, 3DTEE enabled a more confident diagnosis of dissection because the dissection flap when viewed en face presented as a sheet of tissue rather than a linear echo seen on 2DTEE which can be confused with an artifact. 2DTEE missed dissection in one patient. In six cases the dissection flap involved the right coronary artery orifice by 3DTEE and surgery. These were missed by 2DTEE. Aortic regurgitation severity was more comprehensively assessed by 3DTEE than 2DTEE. Aneurysm size by 3DTEE correlated well with 2DTEE and surgery/computed tomography scan. In conclusion, 3DTEE provides incremental information over 2DTEE in patients with aortic aneurysm and dissection.  相似文献   

14.
Libman-Sacks endocarditis (LSE) is a common manifestation of valve disease in antiphospholipid syndrome. Mitral valve LSE is characterized by verrucous vegetations on the atrial surfaces of valve leaflets. In this report, mitral valve LSE was visualized by real time 3D transesophageal echocardiography (TEE). 3D TEE provides a unique en face view of the mitral valve akin to a surgical or autopsy view that allows for an accurate determination of the size, shape, and location of the vegetations.  相似文献   

15.
Accurate echocardiographic evaluation of the pulmonary valve is technically difficult because of its close proximity to the left lung, which often limits decision making. Pulmonary valvotomy is the intervention of choice for symptomatic pulmonary valve stenosis, but fluoroscopy lacks appropriate real time anatomic detail. In this report, we present a case where direct imaging of the pulmonary valve with live/real time three‐dimensional transesophageal echocardiography (3DTEE) aided in accurate evaluation and was then used to help guide and monitor successful valvuloplasty of a stenotic pulmonary valve bioprosthesis. We demonstrate that even in cases where two‐dimensional (2D) evaluation of the pulmonary valve is difficult, the use of live/real time 3DTEE allows for accurate evaluation of bioprosthetic pulmonary valve structure and function, and enhances the precision and monitoring of percutaneous valvuloplasty.  相似文献   

16.
We present two cases in whom live/real time three‐dimensional transesophageal echocardiography (3DTEE) provided incremental value in the assessment of atherosclerotic disease in the aorta. In one patient, it identified additional atherosclerotic ulcers as well as thrombi within them which were missed by two‐dimensional (2D) TEE. In both cases, the size of the large mobile atherosclerotic plaque was underestimated by 2DTEE as compared with 3DTEE. Furthermore, 3DTEE provided volume quantification of the thrombi and ulcers which is not possible by 2DTEE. The echocardiographic findings of atherosclerotic plaques were confirmed by computed tomography in one patient and by surgery in the other.  相似文献   

17.
The echocardiographic findings were correlated with the clinical findings and outcome in 23 patients with tricuspid valve or pulmonary valve endocarditis. There were 15 males and 8 females with a mean age of 33.1 ± 8.4 years. Eighteen patients had tricuspid valve endocarditis, 1 patient had pulmonary valve endocarditis, 3 patients had concomitant mitral valve and tricuspid valve endocarditis, and 1 patient had tricuspid valve and pulmonary valve endocarditis. Twenty of the 23 (87%) patients had a history of intravenous drug abuse. The most common organisms were Staphylococcus aureus (10 of 23 patients or 43%), Streptococcus viridans (5 patients) and Pseudomonas aeruginosa (4 patients). Pulmonary manifestations with septic pulmonary emboli were present in 1823 (80%) patients, and a regurgitant murmur in 1623 (73%) patients. Vegetations on the tricuspid valve or pulmonary valve were detected in all patients who had 2D echo, but they were missed by M-mode echo in 2 patients. Nine of the 23 patients (40%) improved on medical therapy, 5 (21%) expired, and 7 (30%) required surgery (tricuspid valve or pulmonary valve replacement in 3, and tricuspid valve excision without replacement in 4). Conclusions: (1) 11 of 13 patients with persistent infection, multivalvular involvement, fungal or Pseudomonas infection and increasing size of vegetations by echo died or underwent surgery compared to only 1 of 8 patients without these features (P < 0.01). (2) Staphylococcus aureus infection (10 patients) and flail tricuspid valve or pulmonary valve by echo (6 patients) were not predictive of outcome.  相似文献   

18.
Aorto‐atrial fistulas are rare, but important complications resulting from aortic valve infective endocarditis, aortic valve surgery, or aortic dissection. We hereby report a case of a 20‐year male, referred to us with infective endocarditis of the native aortic valve with severe aortic regurgitation and symptoms of heart failure. Detailed evaluation with two‐dimensional and three‐dimensional transthoracic echocardiography revealed aorto‐left atrial fistula secondary to the involvement of the mitral–aortic intervalvular fibrosa (MAIVF) region. The patient underwent successful removal of the vegetations, closure of the defect along with aortic valve replacement, and mitral valve repair.  相似文献   

19.
Moderate‐to‐severe tricuspid regurgitation affects approximately 1.6 million people in the United States. An estimated 8000 patients will undergo tricuspid surgery annually, leaving a large number of patients with this condition untreated. Many of these individuals who are not referred for surgery engender a large unmet clinical need; this may be primarily due to the surgical risk involved. In persons who are categorized as high‐risk surgical candidates, percutaneous procedures present a viable alternative. The majority of developmental attention as regards percutaneous approaches has been focused on the aortic and mitral valves recently, but few data are available about the feasibility and efficacy of minimally invasive tricuspid valve treatment. We review the usefulness of two‐ and three‐dimensional echocardiography in the assessment of the tricuspid valve with special reference to recent interest in percutaneous repair and prosthetic valve implantation procedures for severe functional tricuspid regurgitation.  相似文献   

20.
We describe the use of a nonstandard left infraclavicular approach in making the diagnosis of an infected valved conduit with two‐dimensional transthoracic echocardiography. The patient was an adult with tetralogy of Fallot and pulmonary atresia who had undergone multiple surgical repair procedures. The initial diagnosis of infective endocarditis was made by transesophageal echocardiography. Both techniques demonstrated a single, large vegetation in the conduit. Live/real time three‐dimensional transthoracic echocardiography, on the other hand, provided further information by demonstrating several additional vegetations in the conduit and more comprehensively assessed their size by enabling measurement of their azimuthal dimensions and volumes. The patient was treated with antibiotics with complete resolution of the vegetations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号