1.
Particle size distribution of delivered aerosols and the total mass of drug delivered from the inhaler are important determinants of pulmonary deposition and response to inhalation therapy. Inhalation flow rate may vary between patients and from dose to dose. The Andersen Sampler (AS) cascade impactor operated at flow rates of 30 and 55 L/min and the Marple-Miller Impactor (MMI) operated at flow rates of 30, 55, and 80 L/min were used in this study to investigate the influence of airflow rate on the particle size distributions of inhalation products. Total mass of drug delivered from the inhaler, fine particle mass, fine particle fraction, percentage of nonrespirable particles, and amount of formulation retained within the inhaler were determined by ultraviolet spectrophotometry for several commercial bronchodilator products purchased in the marketplace, including a pressurized metered-dose inhaler (pMDI), breath-actuated pressurized inhaler (BAMDI), and three dry powder inhalers (DPIs), two containing salbutamol sulphate and the other containing terbutaline sulphate. Varying the flow rate through the cascade impactor produced no significant change in performance of the pressurized inhalers. Increasing the flow rate produced a greater mass of drug delivered and an increase in respirable particle mass and fraction from all DPIs tested.  相似文献   

2.
Aims The number of dry powder inhaler (DPI) devices could increase because they are easier to use than a metered dose inhaler (MDI). Using urinary excretion, the relative bioavailability of salbutamol to the lungs and the body for a prototype DPI has been compared with an MDI.
Methods A randomized, double-blind, two way crossover study compared the amount of salbutamol in the urine 30  min following inhalation of 2×100  μg salbutamol from a prototype DPI (Innovata Biomed Ltd, UK) and a Ventolin® (Allen and Hanburys Ltd, UK) MDI in 10 volunteers. The amount of salbutamol and its metabolite, the ester sulphate conjugate, renally excreted up to 24  h post inhalation was also determined to evaluate the relative bioavailability of salbutamol to the body.
Results The mean (s.d.) 30  min post-treatment urinary excretion for the prototype DPI and MDI was 8.4 (2.6) and 5.0 (1.9)  μg, respectively ( P <0.001). The total amount of salbutamol and its ester metabolite excreted in the urine over the 24  h period after inhalation was 187.9 (77.6) and 137.6 (40.0)  μg ( P <0.05).
Conclusions The prototype DPI delivered more salbutamol to the body and the lungs than a conventional MDI. This finding supports further development of the prototype DPI. The urinary salbutamol method is able to discriminate between two different inhalation systems.  相似文献   

3.
FK224 is a cyclopeptide drug with poor oral absorption due to proteolysis in the gastrointestinal tract. The objectives of this study were to investigate the absorption of FK224 from the lung in healthy volunteers, and compare the pharmacokinetic profiles of FK224 after inhalation from a pressurized metered dose inhaler (pMDI) and dry powder inhaler (DPI). The pMDI (Suspension type, 1 mg as FK224/puff) and DPI (4 mg and 10 mg as FK224/capsule, using Spinhaler as the device) were developed by formulating the same micronized particles of FK224 which were premixed with beta-cyclodextrin (beta-CyD) to improve the solubility of FK224. In the case of pMDI, 1, 4 or 8 mg was inhaled by the corresponding number of puffs with the pMDI. In addition, the in vitro drug delivery characteristics of the inhalers were evaluated using a multistage liquid impinger. In both inhalers, it was observed that FK224 could be absorbed into the systemic circulation from the lungs of the healthy volunteers, and the AUC and C(max) were proportionally increased depending on the emitted dose after inhalation. However, the pharmacokinetic (PK) parameters for DPI were significantly higher than that of pMDI, in spite of usage of the same fine particles for the formulations in both inhalers. Based on the distribution from the in vitro examination, the fine particle dose, which is defined as the dose region delivered as particles <3.8 microm, was calculated from the emitted dose inhaled by the healthy volunteers. It was found that the PK parameters for both inhalers were proportionally increased depending on the predicted fine particle dose regardless of the type of inhaler. This suggests that the absorption from the lung is influenced by the fine particle dose. We concluded that DPI is a suitable inhaler for FK224, and the alveolus, which is generally known as the site of action of the fine particles, is a possible absorptive site for FK224.  相似文献   

4.
A novel, compact, and highly efficient dry powder inhaler (DPI) with low mouth-throat deposition is described. The performance of this DPI was evaluated by measuring both (1) the total aerosol deposition in and distal to an idealized mouth-throat cast and (2) the fine particle fraction (FPF) using a standard Mark II Anderson impactor. Ultraviolet (UV) spectroscopy techniques were used in the aerosol deposition measurements. Two inhalation aerosol powders, namely budesonide (extracted from a Pulmicort/Turbuhaler multi-dose device, 200 microg/dose) and ciprofloxacin + lipid + lactose (in-house), were dispersed by the DPI at a steady inhalation flow rate of 60 L/min. The newly developed DPI had a total aerosol delivery distal to the mouth-throat cast of 50.5% +/- 3.04% and 69.7% +/- 1.5% for the budesonide and ciprofloxacin + lipid + lactose aerosols, respectively. This is a significant improvement over the Turbuhaler original device delivery of 34.5% +/- 5.2%, particularly considering that in vitro mouth-throat deposition dropped from 27.5% +/- 5.4% with the budesonide Turbuhaler to 11.0% +/- 3.5% with the present inhaler. The different lung deliveries from the same inhaler for the two formulations above also confirm that the overall performance of an inhaler is optimizable via powder formulations.  相似文献   

5.
本文比较了10例哮喘患者直接从定量压力气雾器或经喘必疗雾化器单剂量(0.5mg)吸入特布他林的支气管舒张效果。测定吸药前和吸药后15,30,60和120min的肺功能结果:8例使用定量压力气雾器正确者加用喘必疗雾化器与否效果相同,其余2例不能正确使用定量压力气雾器者用喘必疗雾化器后支气管舒张效果提高。  相似文献   

6.
The mometasone furoate dry powder inhaler (MF-DPI) is a multiple-dose, breath-actuated inhaler that uses agglomerates of micronized MF and lactose. In vitro analyses evaluated dose uniformity, variability, and particle size distribution of the MF-DPI. Tests of first, middle, and end doses from 10 inhalers each of the 200-microg MF/inhalation and 400-microg MF/inhalation dose sizes found that delivered doses (doses emitted from the inhaler) ranged from 91% to 112% of claimed doses for all tested DPIs. The mean MF doses delivered at 28.3 L/min were 100% and 94% of the doses delivered at 60 L/min for the 200-microg and 400-microg dose sizes, respectively; the relative standard deviation of doses was < or = 6.1% within this range of inhalation rates. At a flow rate of 60 L/min, the mean delivered doses, compared to claimed doses for inspiration times of 1-3 sec, were 102-104% for the 200-microg dose size and 98.8-102% for the 400-microg dose size. The mean cumulative fraction of dose delivered at 60 L/min for 2 sec which consisted of particles of <6.5 microm in diameter was 39.9% (+/-2.5 SD; n = 9) for the 200-microg dose size and 35.6% (+/-3.4 SD; n = 9) for the 400-microg dose size. All MF-DPI inhalers tested were well within U.S. and European compendial standards and regulatory guidelines for dose uniformity. An appropriate and reproducible fraction of the delivered dose was within the optimal particle size range for therapeutic effectiveness.  相似文献   

7.
The aim of this study was to characterise the aerosolisation properties of salbutamol sulphate (SS) from dry powder inhaler (DPI) formulations containing different carrier products. The difference in the elongation ratio (ER) of the different carriers was highlighted. Different set of carriers, namely commercial mannitol (CM), commercial lactose (CL), cooling crystallised mannitol (CCM), acetone crystallised mannitol (ACM) and ethanol crystallised mannitol (ECM) were used and inspected in terms of size, shape, density, crystal form, flowability, and in vitro aerosolisation performance using Multi Stage Liquid Impinger (MSLI) and Aerolizer® inhaler device. Solid-state and morphological characterization showed that CM product was in pure β-form having particles with smaller ER (CM: ER = 1.62 ± 0.04) whereas ACM and ECM mannitol particles were in pure α form with higher ER (ACM: ER = 4.83 ± 0.18, ECM: ER = 5.89 ± 0.19). CCM product crystallised as mixtures of β-form and δ-form and showed the largest variability in terms of particle shape, size, and DPI performance. Linear relationships were established showing that carrier products with higher ER have smaller bulk density (Db), smaller tap density (Dt), higher porosity (P), and poorer flow properties. In vitro aerosolisation assessments showed that the higher the ER of the carrier particles the greater the amounts of SS delivered to lower airway regions indicating enhanced DPI performance. Yet, DPI performance enhancement by increasing carrier ER reached a “limit” as increasing carrier ER from 4.83 ± 0.18 (ACM) to 5.89 ± 0.19 (ECM) did not significantly alter fine particle fraction (FPF) of SS. Also, carrier particles with higher ER were disadvantageous in terms of higher amounts of SS remained in inhaler device (drug loss) and deposited on throat. Linear relationship was established (r2 = 0.87) showing that the higher the carrier ER the lower the drug emission (EM) upon inhalation. Moreover, poorer flowability for carrier products with higher ER is disadvantageous in terms of DPI formulation dose metering and processing on handling scale. In conclusion, despite that using carrier particles with higher ER can considerably increase the amounts of drug delivered to lower airway regions; this enhancement is restricted to certain point. Also, other limitations should be taken into account including higher drug loss and poorer flowability.  相似文献   

8.
Several devices have been developed to overcome the need to co-ordinate actuation with inhalation required during use of a pressurised metered dose inhaler (MDI) and to improve drug delivery to the lung. These include spacer attachments for MDIs, dry powder inhalers and breath-actuated MDIs. The breath-actuated Autohaler (3M Pharmaceuticals) is a compact, multidose inhaler device that, unlike dry powder inhalers, does not rely on the patient's inspiratory effort to aerosolise the dose of medication. Due to its simple operation, the Autohaler is suitable for patients unable to operate a conventional MDI efficiently, including the elderly, children, patients with arthritis and patients with low inspiratory flow rates. The mandatory replacement of chlorofluorocarbon propellants with non-ozone-depleting propellants has given the opportunity to improve drug delivery characteristics of MDIs. Recently, a formulation of beclomethasone dipropionate in hydrofluoroalkane-134a (HFA-BDP), has been developed in a conventional MDI that delivers most of the emitted dose to the lung. Drug deposition studies show that the HFA-BDP formulation in the Autohaler device has a similar lung deposition pattern to drug delivered from the MDI, when used correctly, and dose delivery is consistent across a wide range of inspiratory flow rates. Furthermore, HFA-BDP Autohaler has similar clinical benefits to CFC-BDP Autohaler but at less than half the dose. HFA-BDP Autohaler offers a useful CFC-free delivery option for patients challenged by the conventional MDI device.  相似文献   

9.
陈保垒  朱俊  卢嘉彤  金坚 《药学研究》2017,36(5):272-275
目的 考察驱动器的规格——孔径、孔长以及吸入辅助装置的使用对气雾剂体外沉积性质的影响.方法 以自制丙酸氟替卡松混悬型气雾剂为模型药物,装配不同规格的驱动器,使用Andersen多级撞击器(Andersen cascade impactor,ACI)测定体外沉积率;将丙酸氟替卡松气雾剂装配筛选好的特定规格的驱动器,分别在不使用吸入辅助装置与使用吸入辅助装置的情况下,对体外沉积性质进行对比研究.结果 在孔径固定的情况下,随着孔长的延长,驱动器的残留量降低,Andersen多级撞击器装置的L型连接管沉积量增加,微细粒子剂量降低.在孔长固定的情况下,随着孔径的增加,驱动器的残留量降低,Andersen多级撞击器装置的L型连接管沉积量增加,微细粒子剂量降低.根据试验结果、混悬型气雾剂本身的剂型特点以及驱动器的实际使用情况,最终,将0.42 mm孔径、0.70 mm孔长的驱动器作为优选驱动器;在使用吸入辅助装置的情况下,Andersen多级撞击器装置L型连接管的沉积量极大地降低,微细粒子剂量增加,原来沉积在L型连接管的大粒子很大一部分被截留在吸入辅助装置当中.结论 驱动器的规格会对吸入气雾剂的体外沉积产生一定的影响,在药品研发的过程中,可根据气雾剂产品的具体特点(溶液型或混悬型,原料药的粒径大小等)进行驱动器的筛选;吸入辅助装置的使用可以提高气雾剂的药物利用率,推荐患者用药时使用.  相似文献   

10.
The aim of this study was to develop a novel fluticasone propionate (FP) and salmeterol xinafoate (SX)-loaded dry powder inhaler (DPI) system, which was composed of powder formulation and performance. The air flow resistances were determined with various types of DPI device, showing that the modified RS01 device gave the specific resistance similar to the commercial DPI device. The particle properties of FP, SX, and inhalation grade lactose particles, such as particle size, size distribution, and fine content, were assessed. Subsequently, the aerodynamic behaviors of the DPI powder formulations were evaluated by the in vitro deposition of drugs in the DPI products using Andersen cascade impactor. Amongst the DPI powder formulations tested, the formulation composed of FP, SX, Respitose® SV003, Respitose® SV010, and Respitose® ML006 at the weight ratio of 0.5/0.145/19/19/2 gave depositions, emitted dose, fine particle dose, fine particle fraction, and mass median aerodynamic diameter of drugs similar to the commercial product, suggesting that they had similar aerodynamic behaviors. Furthermore, it gave excellent content uniformity. Thus, this DPI using the modified RS01 device would be recommended as a candidate for FP and SX-loaded pharmaceutical DPI products.  相似文献   

11.
Magnussen H 《Current medical research and opinion》2005,21(Z4):S39-46; discussion S47
Inhalation therapy is the preferred route of administration of anti-asthmatic drugs to the lungs. However, the vast majority of patients cannot use their inhalers correctly, particularly pressurised metered dose inhalers (pMDIs). The actual proportion of patients who do not use their inhalers correctly may even be under-estimated as GPs tend to over-estimate correct inhalation technique. Dry powder inhalers (DPIs) have many advantages over pMDIs. Unlike pMDIs, they are environmentally-friendly, contain no propellant gases and, more importantly, they are breath-activated, so that the patient does not need to coordinate actuation of the inhaler with inspiration. Three key parameters for correct inhaler use should be considered when evaluating existing or future DPI devices and especially when choosing the appropriate device for the patient: (1) usability, (2) particle size distribution of the emitted drug and (3) intrinsic airflow resistance of the device. The Novolizer is a breath-activated, multidose, refillable DPI. It is easy to use correctly, has multiple feedback and control mechanisms which guide the patient through the correct inhalation manoeuvre. In addition, the Novolizer has an intelligent dose counter, which resets only after a correct inhalation and may help to monitor patient compliance. The Novolizer has a comparable or better lung deposition than the Turbuhaler at similar or higher peak inspiratory flow (PIF) rates. A flow trigger valve system ensures a clinically effective fine particle fraction (FPF) and sufficient drug delivery, which is important for a good lung deposition. The FPF produced through the Novolizer is also relatively independent of flow rate and the device shows better reproducibility of metering and delivery performance compared to the Turbuhaler. The low-to-medium airflow resistance means that the Novolizer is easy for patients to use correctly. Even children, patients with severe asthma and patients with moderate-to-severe chronic obstructive pulmonary disease (COPD) have no problems to generate the trigger inspiratory flow rate required to activate the Novolizer. The Novolizer uses an advanced DPI technology and may improve patient compliance.  相似文献   

12.
Introduction: Airway inflammation and remodelling in asthma occur in the large airways and also in the small airways. The small airways are those < 2 mm in diameter and are significant sites of chronic asthmatic inflammation. It is important, therefore, to target the small as well as the large airways in any strategy for effective treatment of this disease.

Areas covered: The present review deals with the recently developed fixed dose drug combination of beclometasone dipropionate/formoterol fumarate that emits extrafine particles when delivered from an innovative dry powder inhaler (DPI), NEXThaler®. The aim is to present the technical and clinical aspects of aerosolized drug delivery to the lungs.

Expert opinion: The data show that the NEXThaler DPI is an efficient device for the management of persistent asthma. The evaluation of the inhalation profiles through the NEXThaler DPI demonstrates that device activation and consistent dose delivery occurs at patient achievable inhalation flow rates, and supports the broad utility of the NEXThaler DPI in patients with asthma. Overall, all the effectiveness, efficiency and satisfaction outcomes demonstrate the NEXThaler DPI is easy to use.  相似文献   

13.
A total of 198 children aged 3 to 15 years inhaled a single dose of 200 micrograms budesonide from a Nebuhaler pressurized metered dose inhaler (pMDI) and a Turbuhaler dry powder inhaler in a randomized crossover study. The budesonide dose delivered to a patient was assessed by measuring the amount of drug deposited on a filter inserted between the inhaler outlet and the patient's mouth. The dose of budesonide deposited on the filter and the estimated dose of particles with a mass median aerodynamic diameter (MMAD) of 5 microns or less after inhalation from the Turbuhaler were both approximately twice the values inhaled from the pMDI Nebuhaler in children less than 5 years of age (P < 0.01). The variation in the dose delivered to the patient was similar for the two inhalers in children over 5 years old. In 3- to 4-year-old children, dose delivery to the patient was higher and/or more consistent from the pMDI Nebuhaler than from the Turbuhaler. Filter dose after Turbuhaler treatment varied significantly from peak inspiratory flow rate through the Turbuhaler (PIFTbh) (P < 0.01). The percentage of children producing a PIFTbh greater than 50 L/min decreased with age (89%, 45%, and 14% in 5-, 4-, and 3-year-old children, respectively). It is concluded that drug delivery to a child with asthma varies with age and inhalation device. Further studies are needed to assess the clinical importance of this finding.  相似文献   

14.
Formoterol, a long-acting beta (2)-agonist with a rapid onset of bronchodilation, is available in various delivery devices. However, differences in the size and uniformity of drug particles generated by different devices may result in variable clinical effects. The present study compared in vitro the aerodynamic particle size distribution, emitted dose and device resistance of formoterol delivered via Foradil Aerolizer (Foradil P) with those a non-proprietary single-dose capsule inhaler (ratiopharm), using an 8-stage Andersen Cascade Impactor set at a flow of 60 L/min. Relative to the formoterol ratiopharm capsule inhaler, Foradil Aerolizer produced particles with a smaller mass median aerodynamic diameter (3.5 vs. 4.1 microm, p = 0.018) and a smaller measured particle diameter distribution (geometric standard deviation 2.2 vs. 2.5, p = 0.048). The Foradil Aerolizer produced a 44% higher fine particle dose than the single-dose capsule inhaler (2.6 vs. 1.8 microg, p = 0.0001). Although the single-dose capsule inhaler produced a higher total emitted dose than that from Foradil Aerolizer (11.2 vs. 10.0 microg, p = 0.155, not significant), the respirable fraction from Foradil Aerolizer was 58% higher (25.7 vs. 16.3%, p = 2 x 10(8)). Both devices had a similarly low airflow resistance. These relative particle size profiles suggest that the Aerolizer may provide a more clinically effective delivery of formoterol to the lungs at the high inspiratory flows such as are typically achieved using this device.  相似文献   

15.
Gamma scintigraphic imaging was employed in 10 healthy volunteers to compare the total and regional lung deposition of aerosols generated by two delivery platforms that permitted microprocessor-controlled actuation at an optimal point during inhalation. An aqueous solution containing 99mTc-DTPA was used to assess the deposition of aerosols delivered by inhalation from two successive unit-dosage forms (44 microl volume) using a prototype of a novel liquid aerosol system (AERx Pulmonary Delivery System). This was compared with aerosol deposition after inhalation of two 50 microl puffs of a 99mTc-HMPAO-labeled solution formulation from a pressurized metered dose inhaler (MDI). The in vitro size characteristics of the radiolabeled aerosols were determined by cascade impaction. For the AERx system, the predicted lung delivery efficiency based on the product of emitted dose (60.8%, coefficient of variation (CV)=12%) and fine particle fraction (% by mass of aerosol particles <5.7 microm in diameter) was 53.3% (CV=13%). For the solution MDI, the emitted dose was 62.9% (CV=13%) and the predicted lung dose was 44. 9% (CV=15%). The AERx system demonstrated efficient and reproducible dosing characteristics in vivo. Of the dose loaded into the device, the mean percent reaching the lungs was 53.3% (CV=10%), with only 6. 9% located in the oropharynx/stomach. In contrast, the lung deposition from the solution MDI was significantly less (21.7%) and more variable (CV=31%), with 42.0% of the radiolabel detected in the oropharynx/stomach. Analysis of the regional deposition of the radioaerosol indicated a homogeneous pattern of deposition after delivery from the AERx system. A predominantly central pattern of distribution occurred after MDI delivery, where the pattern of deposition was biased towards a central zone depicting the conducting airways. The AERx system, in contrast to MDIs, seems highly suited to the delivery of systemically active agents via pulmonary administration.  相似文献   

16.
1. The efficacy of a metered dose inhaler (MDI) is highly dependent on the mode of inhalation. The relatively high built-in resistance in the Turbohaler (TBH), a new dry powder inhaler device for inhalation of terbutaline sulphate and budesonide, reduces the flow during inhalation. We compared five different modes of inhalation using the terbutaline TBH in 10 stable asthmatic subjects, who were tested on 5 consecutive days. 2. Measurement of 10 different parameters of pulmonary function indicated that the full bronchodilatory effect of an inhaled dose was already achieved at 5 min after the inhalation. Inspiratory flows through the TBH varying from 34 to 88 l min-1 resulted in comparable bronchodilation, and a previous exhalation to residual volume proved of no value. However, if, prior to inhalation, an exhalation through the device was performed, a substantially reduced effect was seen. 3. Reducing the inspiratory flow to approximately 34 l min-1 produced slightly reduced side effects and lower plasma terbutaline concentrations.  相似文献   

17.
Salbutamol is a short-acting beta 2 agonist which is effective as a rescue therapy in the treatment of asthma. This study uses in vitro test methods to compare the capability of four alternative devices to deliver an accurate and precise dose of salbutamol. It is demonstrated that the conventional metered dose inhaler (MDI) achieves excellent accuracy and precision in dose delivery. Additionally, it is the most efficient inhaler in terms of generating in-vitro a fine particle fraction from the dose. A spacer device has been shown to further enhance the dosing characteristics. When tested over a wide range of inspiratory air flow rates, the Diskus (GlaxoWellcome, Hertfordshire, UK) has comparable accuracy and precision to the MDI tested at 60 L/min, and it offers an advantage over two alternative dry powder inhalers (DPIs), delivering a more consistent dose across the range of flow rates tested and being more efficient at generating a fine particle fraction than either Turbuhaler (Astra, Lund, Sweden) or Diskhaler (GlaxoWellcome) at both 28 and 60 L/min inspiratory flow rates. Diskus, Diskhaler, Ventolin, Volumatic, and Rotadisk are trademarks of the GlaxoWellcome Group of companies. The Accuhaler is the alternative to the Diskus in those countries where the Diskus trademark is not available. Inspiryl and Turbuhaler are trademarks of the Astra Group of companies.  相似文献   

18.
A new dry powder inhaler, the Ultrahaler, has been developed to deliver nedocromil sodium for the prophylaxis of asthma. This study was performed to compare the lung deposition of nedocromil sodium inhaled from the Ultrahaler at two different inhaled flow rates with that from a pressurised metered dose inhaler (MDI). A scintigraphic study was conducted in 12 healthy volunteers. On each study day, volunteers received a single 4.2 mg dose of nedocromil sodium from the Ultrahaler, using either an optimal (fast) inhaled flow rate or a suboptimal (slow) inhaled flow rate, or two doses of 2 mg nedocromil sodium from an MDI using an optimal (slow) inhaled flow rate. Used optimally, the Ultrahaler deposited significantly more (p < 0.05) of the metered dose in the lungs than either the Ultrahaler used suboptimally or the MDI used optimally [mean (SD) lung deposition values of 13.3 (4.8)%, 9.8 (3.5)%, and 7.5 (2.9)%, respectively]. Oropharyngeal deposition averaged over 80% of the dose for all three treatment regimens. This scintigraphic study demonstrated in vivo proof of concept for the Ultrahaler dry powder inhaler, and provided quantitative data on the relationship in lung deposition between the Ultrahaler and MDI which differed from that predicted by the in vitro fine particle fraction.  相似文献   

19.
OBJECTIVE: To compare the lung and systemic delivery of salbutamol following inhalation from a metered dose inhaler (MDI), a MDI attached to a spacer (MDI+SP) and a nebuliser (NEB) using a urinary pharmacokinetic method. METHOD: Twelve healthy subjects each provided urine samples at 0, 30 min and pooled up to 24 h after the start of 5 x 100 microg salbutamol inhaled from MDI and MDI + SP and after 2.5 mg was delivered by NEB. Following nebulisation, the amount of salbutamol trapped on an exhalation filter together with that remaining in the apparatus was determined. The amount left in the spacer and that leaving the MDI mouthpiece was also determined. Thus, for all the methods, the amount available for inhalation from each study dose was determined. RESULTS: The mean (+/- SD) 30-min urinary excretion amounts of salbutamol for MDI, MDI+SP and NEB were 12.6+/-3.5, 27.1+/-6.0 and 16.1+/-4.6 microg, respectively. The mean ratios (90% confidence intervals) for MDI+SP compared with MDI and NEB were 230.2 (186.7, 273.8) and 183.0 (146.4, 219.7) (both P values<0.001), respectively, while that between MDI and NEB was 134 (110.4, 159.1) (P < 0.05). The mean (+/-SD) 24-h urinary excretion values for salbutamol and its metabolite were 287.0+/-46.5, 198.1+/-34.7 and 253.4+/-138.3 microg, respectively. Following inhalation a mean of 202.9+/-51.5 microg was left in the spacer. Similarly, after nebulisation 1387.7+/-88.9 microg was left in the nebuliser chamber, 26.3+/-8.0 microg in the mouthpiece and 553.8+/-68.5 microg exhaled. The mean emitted dose from the MDI was 88.4+/-6.1 microg per actuation. When normalised for the amounts available for inhalation, the mean amounts of salbutamol excreted in the urine during the first 30 min were 2.86+/-0.78, 9.15+/-1.69 and 3.06+/-0.70% following MDI, MDI + SP and NEB, respectively. CONCLUSION: Five 100-microg doses inhaled from a metered dose inhaler attached to a spacer delivered more to the lungs and less to the systemic circulation than either the same doses from a metered dose inhaler used alone or five times the dose given via a jet nebuliser. Spacers should be routinely used instead of nebulisers to manage patients unless they are short of breath.  相似文献   

20.
The relative lung and systemic bioavailability of sodium cromoglycate following inhalation by different methods have been determined using a urinary excretion pharmacokinetic method. On three separate randomised study days, 7 days apart, subjects inhaled (i) 4x5 mg from an Intal metered dose inhaler (MDI), (ii) 4x5 mg from an MDI attached to a large volume spacer (MDI+SP) and (iii) 20 mg from an Intal Spinhaler (DPI). Urine samples were provided at 0, 0.5, 1, 2, 5 and 24 h post dose. The mean (S.D.) amount of sodium cromoglycate excreted in the urine during the first 30 min post inhalation was 38.1 (27.5), 222.3 (120.3) and 133.1 (92.2) microg following MDI, MDI+SP and DPI, respectively. The mean ratio (90% confidence interval) of these amounts excreted in the urine over the first 30 min for MDI+SP vs. MDI, DPI vs. MDI and MDI+SP vs. DPI was 801.0 (358.0, 1244; p<0.002)%, 457.0 (244.0, 670.0; p<0.02)% and 262.4 (110.2, 414.5)%, respectively. Similarly for the 24 h cumulative amount of sodium cromoglycate excreted over the 24 h post inhalation the ratios were 375.4 (232.9, 517.9; p<0.005)%, 287.5 (183.4, 391.6; p<0.02)% and 211.4 (88.3, 334.5)%, respectively. The results highlight better lung deposition of sodium cromoglycate from a metered dose inhaler attached to a large volume spacer.  相似文献   