首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background  

Since March 2003, we have used the Cousin Bioring in our laparoscopic gastroplasty procedures for morbid obesity. The Bioring belongs to the new generation of adjustable gastric bands. The aim of this study is to review our experience with this particular type of band.  相似文献   

2.
Background: Although gastric bands are safe and effective devices, severe late complications may develop in rare cases. Patients: 3 patients were treated for complete dysphagia after slippage of gastric bands. 2 of the patients were admitted for severe dehydration, 1 of whom developed cerebral venous infarction. Ischemia of the gastric pouch occurred in 1 patient. Results: All 3 patients survived after successful medical therapy and surgical removal of the bands. Bariatric reoperations were performed in 2 patients (gastric sleeve resection, gastric bypass). Conclusion: Complete dysphagia on the basis of band slippage represents a life-threatening acute event, which may occur even years after implantation. Patients and doctors should be informed about this long-term risk of gastric banding.  相似文献   

3.
Background: Although weight loss is an important immediate outcome after gastric banding operations, quality of life (QOL) has been shown to be an equally important outcome measure. Methods: From 1996 to May 2002, 125 consecutive patients have been operated laparoscopically for morbid obesity at our institution with the Swedish Adjustable Gastric Band (SAGB). We compared the Moorehead-Ardelt QOL scores of the first 60 patients, operated at a median of 2 years earlier, with a group consisting of the following consecutive 65 patients, who answered the questionnaire preoperatively. Results: The QOL scores among the operated patients were significantly better (P<0.0001, unpaired t-test) on all domains of the Moorehead-Ardelt questionnaire compared to those not yet operated. Conclusions: Laparoscopic banding with the SAGB has been a safe procedure, with satisfactory weight loss and significant improvement in QOL scores 2 years postoperatively.  相似文献   

4.
The study objective was to ascertain outcomes with the Swedish adjustable gastric band (SAGB) on an intention-to-treat basis in multiple centers across the French social health insurance system. SAGB results at 3-year follow-up are reported. The noncomparative, observational, prospective, consecutive cohort study design sought a 500-patient minimum recruitment geographically representative of continental France. Safety (adverse events [AEs], device-related morbidity, and mortality) and effectiveness (change in body mass index [BMI, kilograms per square meter], percentage excess weight loss, comorbidities, quality of life [QoL]) were assessed. Adjustable gastric band survival was calculated. Thirty-one surgeons in 28 multidisciplinary teams/sites enrolled patients between September 2, 2007 and April 30, 2008. SAGB was successfully implanted in 517 patients: 88.0 % female; mean age, 37.5 years; obesity duration, 15.3 years (baseline: mean BMI, 41.0; comorbidities, 773 in 74.3 % of patients; Bariatric Analysis and Reporting Outcome System (BAROS), 1.4; EuroQoL 5-Dimensions (EQ-5D), 0.61; EuroQoL–visual analog scale (EQ–VAS), 52.3). At 3 years: BMI, 32.2 (mean change, ?9.0; p?<?0.0001); excess weight loss, 47.4 %; comorbidities, 161 in 27.2 %; BAROS, 3.6 (+2.2, p?<?0.0001); EQ-5D, 0.84 (+0.22, p?<?0.0001); EQ–VAS, 73.4 (+21.4, p?<?0.0001). SAGB-induced weight loss was associated with substantially improved QoL. One death occurred and was unrelated to the treatment. No AE was reported in 68.3 % of patients, and no confirmed device-related AE in 77.0 %. Overall AE rate was 0.19 per patient year. Device retention was 87.0 %. Analysis of patients lost to follow-up showed a nonsignificant effect on overall study results. In a prospective, consecutive cohort, “real-world”, nationwide study, the Swedish Adjustable Gastric Band was found safe and effective at 3-year follow-up.  相似文献   

5.
6.
The adjustable gastric band (L)AGB gained popularity as a weight loss procedure. However, long-term results are disappointing; many patients need revision to laparoscopic Roux-en-Y gastric bypass (LRYGB) or sleeve gastrectomy (LSG). The purpose of this study was to assess morbidity, mortality, and results of these two revisional procedures. Fifteen LRYGB studies with a total of 588 patients and eight LSG studies with 286 patients were included. The reason for revision was insufficient weight loss or weight regain in 62.2 and 63.9 % in LRYGB and LSG patients. Short-term complications occurred in 8.5 and 15.7 % and long-term complications in 8.9 and 2.5 %. Reoperation was performed in 6.5 and 3.5 %. Revision to LRYGB or LSG after (L)AGB is feasible and relatively safe. Complication rate is higher than in primary procedures.  相似文献   

7.
8.
Background  Bariatric surgery is currently the only anti-obesity therapy that can deliver weight loss of up to 20–30% of body weight. Laparoscopic adjustable gastric banding (LAGB) and Roux-en-y gastric bypass are the most commonly performed of these surgeries. The mechanisms by which LAGB initiates an increase in satiety remain completely unknown. The aim of this study is to establish a rodent model of adjustable gastric banding (AGB) that will enable investigation of these mechanisms. Methods  Sprague–Dawley rats were implanted with adjustable gastric bands immediately below the gastro-esophageal junction around the glandular stomach. This band, as in humans, can be inflated via an exteriorized port resulting in an incremental impact on the stomach. Results  Rats with an incremental inflation of the AGB showed a clear stepwise reduction in food intake and body weight. Normal food intake and body weight gain were restored with band deflation. Barium-assisted X-ray of the stomach showed the formation of a small gastric pouch proximal to the inflated band in a manner analogous to the human LAGB. Conclusions  This is the first animal model of the AGB that allows incremental inflation for optimal tightening of the band in the conscious animal with corresponding effects on food intake and body weight. This model will allow measurement of acute and chronic neural and hormonal changes following activation of the band in the conscious animal and will provide the potential to inform and improve surgical approaches that are at the forefront of obesity treatments.  相似文献   

9.
Background: A study was performed to assess the usefulness and efficacy of a new type of band (Heliogast?) for laparoscopic adjustable gastric banding (LAGB) for the treatment of morbid obesity, compared with the Lap-Band?. Method: From January to May 2001, a prospective randomized study of 60 LAGB procedures was conducted: group I (n=30), the Lap-Band? system (INAMED); group II (n=30), the Heliogast? band (Hélioscopie). We implanted the devices using the 2-step technique (pars flaccida to peri-gastric) by laparoscopy. Port systems were placed on the rectus sheath and were fixed by non-absorbable sutures. Follow-up of all patients was a minimum of 12 months. Results: There were no differences in operating-time, intra-operative complications, or weight loss during the first 4 weeks after surgery. However, with increasing time, more complications with the Heliogast? band and differences in weight loss favoring the Lap-Band? became significant. Conclusion: Based on the results of this study, we recommend that new bands have independent clinical evaluation before commercialization.  相似文献   

10.

Background

Laparoscopic adjustable gastric banding (LAGB) placements have progressively decreased in recent years. This is related to poor long-term weight loss outcomes and necessity for revision or removal of these bands. Long-term outcome results following LAGB are limited. The aim of our study was to determine the long-term outcome after LAGB at our institution.

Objectives

The aim of our study was to determine the long-term outcome after LAGB at our institution.

Setting

The setting of this is Academic Center, Israel.

Methods

Patients who underwent LAGB between 1999 and 2004 were reviewed. Patient comorbidities and weight loss parameters were collected preoperatively and at defined postoperative periods. Improvement in weight loss was defined as percent excess weight lost, and improvement in comorbidities was defined based on standardized reporting definitions.

Results

In total, 74 (80%) patients who underwent LAGB met inclusion criteria. The mean age at LAGB placement was 50.5 ± 9.6 years, and the mean body mass index (BMI) was 45.5 ± 4.8 kg/m2. Preoperative comorbidities were diabetes mellitus (13.5%), hypertension (32%), hyperlipidemia (12.1%), obstructive sleep apnea (5.4%), joints disease (10.8%), mood disorders (5.4%), and gastro-esophageal reflux disease (GERD) symptoms (8.1%). The mean follow-up was 162.96 ± 13.9 months; 44 patients (59.4%) had their band removed, and 22 (30%) had another bariatric surgery. The follow-up BMI was 35.7 ± 6.9 (p < 0.001), and the % total weight loss was 21.0 ± 0.13. There was no improvement in any of the comorbidities. GERD symptoms worsened at long-term follow-up (p < 0.001). Undergoing another bariatric procedure was associated with a higher weight loss (OR 12.8; CI 95% 1.62–23.9; p = 0.02).

Conclusion

LAGB required removal in the majority of our patients and showed poor resolution of comorbidities with worsening of GERD-related symptoms. Patients who go on to have another bariatric procedure have more durable weight loss outcomes.
  相似文献   

11.

Background  

Bariatric surgery is currently the only effective treatment for morbid obesity. The main advantage of laparoscopic adjustable gastric banding is that this operation is minimally invasive to the stomach and adjustable to the patient’s needs. Few long-term studies on Swedish adjustable gastric banding (SAGB) have been published. We here report our 10-year experience with 785 SAGB procedures.  相似文献   

12.
Although bariatric surgery has proven to be the most effective treatment for morbid obesity, most surgical techniques do have failures. In an effort to improve the reliability, several surgeons started to use a combination of a laparoscopic gastric bypass with an adjustable gastric band. Because of concerns regarding a possible negative outcome, an expert meeting was organized to evaluate the current situation and future application. In total, 104 operations were reported,with several technical variations. The overall complication rate was acceptable, but the percentage of the band erosions was 6.7%, which is too high. The potential advantages (adjustability, maintained access to the stomach and biliary tree, and reversibility) do not compensate for this complication rate. Based on the results and the opinion of the surgeons experienced in this technique, it is concluded that the combination of gastric bypass with an adjustable gastric band to form the pouch is not recommended.  相似文献   

13.
14.
Background  Pouch formation after failed gastric banding bears a risk of anastomotic leakage, bleeding or ischemic damage due to an impaired vascular supply or demanding preparation in the scarry tissue. We evaluated the clinical outcome in patients following Roux-en-Y gastric bypass (RYBP) with and without gastric pouch reconstruction after removal of adjustable gastric bands. Methods  This study comprised 24 morbidly obese patients undergoing RYBP as their final bariatric procedure. Group 1 consisted of eight patients after band migration or pouch dilatation. An esophago-jejunal anastomosis was performed. Group 2 comprised 16 patients with esophageal motility disorders or pouch dilation after banding. A regular-sized pouch was created. Clinical parameters, such as weight loss, complications and a satiety score were assessed. Serum values of ghrelin and gastrin were measured. Results  All but one procedure (Group 2) could be performed by laparoscopy. Mortality rate was 0%. One patient of Group 1 developed a liver abscess that required percutaneous drainage and one patient of Group 2 developed stenosis at the gastrojejunostomy that necessitated endoscopic balloon-dilation. All patients significantly reduced body weight (p < 0.01 compared to preoperative values) during a median follow-up of 37.5 and 31.5 months, respectively. Two out of 16 (12.5%) patients of Group 2 showed pathologic postoperative DeMeester scores. Esophageal body peristalsis did not reveal statistically significant differences between the two groups. Parameters of satiety assessment did not differ between the two groups as did serum values of gastrin and ghrelin. Conclusion  RYBP in patients experiencing adjustable gastric band failure is technically demanding. Esophago-jejunostomy avoids preparation in scarred tissue whereas routine pouch formation may increase the risk for complications. Adapted procedural strategy is recommended based on intraoperative decision making.  相似文献   

15.
Laparoscopic adjustable gastric banding (LAGB) has become an increasingly popular option to treat morbid obesity. Esophageal dysmotility secondary to LAGB has been described, but is usually reversible after removal of the band. Long-term esophageal dysmotility persisting after removal of the band is an unusual and not yet described complication. We report the case of a 58-year-old obese patient who developed severe dysphagia and vomiting associated with atypical esophageal dysmotility 22 months after gastric band placement. Radiological exploration revealed no acute band slippage but only a pseudoachalasia. Device deflation and then band removal were required in an attempt to treat her symptoms. Esophageal dysmotility persisted for several months after band removal and was still present after a Rouxen-Y gastric bypass performed as revisional operation. Possible mechanisms generating this complication and clinical implications are discussed.  相似文献   

16.
Dargent J 《Obesity surgery》2003,13(1):111-115
Background: Laparoscopic adjustable gastric banding (LAGB) in France is currently the most common bariatric surgical procedure for the treatment of severe obesity; its most reported complication is band slippage and/or pouch dilatation, which usually requires reoperation. It is highly important to assess whether a change in the operation could improve these results. Methods: From April 1995 to October 2001, 973 patients underwent LAGB in our institution. Since January 1999, our technique changed: the band was positioned according to the so called "pars flaccida technique", ie. around the gastric vessel instead of close to the gastric wall. 511 patients had been operated before this period, and 462 after. Other details in the technique did not change (dissection above the lesser sac, no posterior stitch, three anterior stitches), meaning that potential differences could not be related to a learning curve. Results: Band slippage occurred in 27 patients of the first group during the first period of 34 months (5.2%), and 5 more afterwards (total 6.2%). Only 3 patients of the second group (0.6%) had a slippage during the same period of time. Conclusion: Although the problem of band slippage is not likely to be completely solved, changing the technique has made it possible to decrease the rate of this complication.The height or the shape of different types of band also remain under scrutiny.  相似文献   

17.
Background: Laparoscopic adjustable gastric banding is the least invasive bariatric operation. However, just isolated attempts to perform this procedure as a Day Case have been published. This study highlights some aspects that might contribute to safe patient discharge within 23 hours after LAGB. Methods: Prospective evaluation of 20 consecutive patients was carried out. Patients were indicated for laparoscopic Swedish adjustable gastric banding (SAGB, Obtech, Ethicon Endo-Surgery) in a private Bariatric center in the first 6 months of 2003. The effect of extensive pre- and immediate postoperative education and psychological support, and information on postoperative health consequences delivered through a multi-disciplinary bariatric team effort, was evaluated, regarding the influence of these facilitators in shortening the length of hospital stay. Results: Mean preoperative BMI of the 20 patients entering the study was 42.3. Mean operating-time was 91 minutes (58-112 min). Time spent on information and education of each patient was 60 minutes in total during the preoperative period. Average postoperative hospitalization was 21 hours. There were no intraoperative or early postoperative complications. Excess weight loss was 44% at 12 months after surgery. Conclusion: SAGB performed on a Day Case basis in selected patients who are subjected to intensive pre- and immediate postoperative dedicated education appears to be a feasible alternative.  相似文献   

18.
Outcome after Laparoscopic Adjustable Gastric Banding – 8 Years Experience   总被引:18,自引:12,他引:6  
Background: Laparoscopic adjustable gastric banding (LAGB) has been our choice operation for morbid obesity since 1994. Despite a long list of publications about the LAGB during recent years, the evidence with regard to long-term weight loss after LAGB has been rather sparse. The outcome of the first 100 patients and the total number of 984 LAGB procedures were evaluated. Methods: 984 consecutive patients (82.5% female) underwent LAGB. Initial body weight was 132.2 ± 23.9 SD kg and body mass index (BMI) was 46.8 ± 7.2 kg/m2. Mean age was 37.9 (18-65). Retrogastric placement was performed in 577 patients up to June 1998. Thereafter, the pars flaccida to perigastric (two-step technique) was used in the following 407 patients. Results: Mortality and conversion rates were 0. Follow-up of the first 100 patients has been 97% and ranges in the following years between 95% and 100% (mean 97.2%). Median follow-up of the first 100 patients who were available for follow-up was 98.9 months (8.24 years). Median follow-up of all patients was 55.5 months (range 99-1). Early complications were 1 gastric perforation after previous hiatal surgery and 1 gastric slippage (band was removed). All complications were seen during the first 100 procedures. Late complications of the first 100 cases included 17 slippages requiring reinterventions during the following years; total rate of slippage decreased later to 3.7%. Mean excess weight loss was 59.3% after 8 years, if patients with band loss are excluded. BMI dropped from 46.8 to 32.3 kg/m2. 5 patients of the first 100 LAGB had the band removed, followed by weight gain; 3 of the 5 patients underwent laparoscopic Roux-en-Y gastric bypass (LRYGBP) with successful weight loss after the redo-surgery. 14 patients were switched to a "banded" LRYGBP and 2 patients to a LRYGBP during 2001-2002. The quality of life indices were still improved in 82% of the first 100 patients. The percentages of good and excellent results were at the highest level at 2 years after LAGB (92%). Conclusions: LAGB is safe, with a lower complication rate than other bariatric operations. Reoperations can be performed laparoscopically with low morbidity and short hospitalizations. The LAGB seems to be the basic bariatric procedure, which can be switched laparoscopically to combined bariatric procedures if treatment fails. After the learning curve of the surgeon, results are markedly improved. On the basis of 8 years long-term follow-up, it is an effective procedure.  相似文献   

19.
20.

Background  

Laparoscopic adjustable gastric banding (LAGB) is a safe and frequently performed bariatric procedure. Unfortunately, re-operations are often necessary. Reports on the success of revisional procedures are scarce and show variable results, either supporting or declining the idea of revising LAGB. This study describes a large cohort of re-operations after failed LAGB to determine the success of revision.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏