首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 125 毫秒
1.
目的评价99Tcm--双(N-乙氧基,N-乙基-二硫代氨基甲酸酯)氮化锝(99Tcm-NOET)静息门控断层心肌灌注显像对冠心病患者的诊断价值。方法疑诊为冠心病的45例患者注射925MBq 99Tcm-NOET后1h用SPECT行静息门控心肌灌注显像,获得舒张未期容积(EDV)、收缩未期容积(ESV)、左室射血分数(LVEF)等心功能参数和舒张末期容积灌注、局部射血分数、局部室壁活动和室壁增厚度4个靶心图。所有患者在1周内行冠状动脉造影,将冠状动脉狭窄≥50%定为病变血管。根据冠状动脉造影结果将其分为心肌梗死组、心肌缺血组和对照组三组。结果99Tcm-NOET静息门控SPECT诊断冠心病的灵敏度和特异度分别为68.42%和83.33%。心肌梗死组的心功能参数[EDV=(129.32±9.14)ml,ESV=(80.97±9.49)ml,LVEF=(40.15±3.28)%】与对照组【EDV=(80.91±3.12)ml,ESV=(30.12±1.79)ml,LVEF=(63.51±1.04)%]相比,统计学差异有显著性(EDV:F=22.103,ESV:F=32.277,LVEF:F=42.60:4,均为P〈0.01),心肌缺血组的心功能参数[(EDV=(70.83±3.46)ml,ESV=(25.13±2.85)ml,LVEF=(65.55±2.62)%1与对照组相比,统计学差异无显著性意义。心肌梗死组左室心肌共分为460个节段,其中209个节段局部灌注、局部射血分数、局部室壁活动和室壁增厚度4个靶心图均异常。局部灌注异常的节段共328个节段,伴有局部射血分数、局部室壁活动和室壁增厚度异常分别有250个、240个和276个节段。局部灌注异常的节段与局部射血分数、局部室壁活动和室壁增厚度异常的节段不完全匹配。结论99Tcm-NOET静息门控心肌灌注显像对冠心病的诊断有较大临床应用价值,所获得的整体心室功能参数在心肌梗死的评价中有优越性,但对心肌缺血的诊断价值不大。心肌梗死中存在有不少的局部灌注与心肌?  相似文献   

2.
定量门控99Tcm-tetrofosmin心肌显像测量左室功能   总被引:10,自引:3,他引:7  
目的探讨定量门控(QG)99Tcm-tetrofosmin心肌显像测量左室功能的临床应用价值.方法74例受试者进行了门控99Tcm-tetrofosmin心肌显像,采用QGSPECT专用分析程序全自动测量左室功能.其中36例同时进行静息门控心室显像,以比较两种方法测量左室功能的相关性.结果①74例99Tcm-tetrofosminQGSPECT全自动定量测定左室功能均获成功.②QGSPECT全自动测量36例受试者的静息左室射血分数(LVEF)、舒张末期容积(EDV)、收缩末期容积(ESV)分别与静息门控心室显像计算结果显著正相关(r分别为0.859,0.914,0.950,P均<0.001),重复性好.③心肌缺血组(n=28)静息LVEF与对照组(n=23)比较差异无显著性,而心肌梗死组(n=9)静息LVEF明显低于对照组(t=6.33,P<0.001).结论定量门控心肌显像99Tcm-tetrofosmin能准确评价左室功能.  相似文献   

3.
目的 探讨使用亚锡替曲膦药盒能否得到满足临床需要的99Tcm-替曲膦(TF)以及1d内完成99Tcm-TF运动-静息G-MPI的可行性.方法 回顾性分析52例行99Tcm-TF运动-静息G-MPI且均有CAG结果的受试者资料.标记亚锡替曲膦并进行放化纯检测.1d内对受试者分别在运动负荷及静息状态下静脉注射99Tcm-TF 370和740 MBq,30 min时行G-MPI.2次注射显像剂间隔时间为(129±4)min.运动负荷状态下注射99Tcm-TF后加行1~ 30 min前位胸腹部平面动态显像和2h前位平面显像.用ROI技术分析胸腹部平面动态像,得到左室心肌、肝及胸部放射性变化情况;用Cedars心肌定量分析软件分析左室心肌各节段灌注情况及左室功能参数(LVEF、EDV、ESV等).1周内行超声心动图检查,获取LVEF、EDV和ESV.对运动-静息G-MPI(取2次显像平均值)心功能参数与超声心动图结果采用SPSS 17.0进行配对t检验.结果 99Tcm-TF放化纯为(97.5±0.4)%.G-MPI左室心肌显影清晰;动态显像示左室心肌与肝放射性比值12 min后逐渐增大,30 min时达0.710,2h延迟显像左室心肌内放射性基本清除.以CAG为“金标准”,G-MPI诊断心肌缺血的灵敏度为84.6% (22/26),特异性为92.3%(24/26);G-MPI与超声心动图测定的LVEF、EDV和ESV分别为(60.27±7.49)%和(60.84±5.98)%,(97.82±18.98)ml与(98.70-±17.89) ml,(47.67 ±10.32) ml与(45.49 ±10.15) ml,差异均无统计学意义(t=1.254、0.835和0.981,P均>0.05).结论 采用亚锡替曲膦药盒标记得到的99Tcm-TF能够满足临床需要;99Tcm-TF能够在1d内完成运动负荷及静息G-MPI,可作为常规评价心肌灌注及左室功能的显像剂.  相似文献   

4.
目的 探讨定量门控 (QG) 99Tcm tetrofosmin心肌显像测量左室功能的临床应用价值。方法  74例受试者进行了门控99Tcm tetrofosmin心肌显像 ,采用QGSPECT专用分析程序全自动测量左室功能。其中 36例同时进行静息门控心室显像 ,以比较两种方法测量左室功能的相关性。结果 ①74例99Tcm tetrofosminQGSPECT全自动定量测定左室功能均获成功。②QGSPECT全自动测量 36例受试者的静息左室射血分数 (LVEF)、舒张末期容积 (EDV)、收缩末期容积 (ESV)分别与静息门控心室显像计算结果显著正相关 (r分别为 0 .85 9,0 .914,0 .95 0 ,P均 <0 .0 0 1) ,重复性好。③心肌缺血组 (n =2 8)静息LVEF与对照组 (n =2 3)比较差异无显著性 ,而心肌梗死组 (n =9)静息LVEF明显低于对照组 (t=6 .33,P <0 .0 0 1)。结论 定量门控心肌显像99Tcm tetrofosmin能准确评价左室功能  相似文献   

5.
核素显像识别存活心肌的临床应用进展   总被引:2,自引:1,他引:1  
存活心肌的判断对冠心病患者治疗方案的选择及预后十分重要。201Tl再注射法、硝酸甘油介入的静息99Tcm-sestamibi法增强了心肌灌注核素体层显像对存活心肌的检测能力,门控SPECT技术能在评估心肌灌注的同时计算LVEF(左心室射血分数)、局部室壁运动和局部室壁增厚率,具有符合线路的SPECT可以进行心肌代谢显像及灌注显像,其对存活心肌的检测能力可能接近于PET,而检查费用可大大降低。  相似文献   

6.
核素显像识别存活心肌的临床应用进展   总被引:1,自引:1,他引:0  
存活心肌的判断对冠心病患者治疗方案的选择及预后十分重要。^201Tl再注射法、硝酸甘油介入的静息^99Tc^m-sestamibi法增强了心肌灌注核素体层显像对存活心肌的检测能力,门控SPECT技术能在评估心肌灌注的同时计算LVEF(左心室射血分数)、局部室壁运动和局部室壁增厚率,具有符合线路的SPECT可以进行心肌代谢显像及灌注显像,其对存活心肌的检测能力可能接近于PET,而检查费用可大大降低。  相似文献   

7.
双核素门控心肌断层显像对心肌缺血的诊断价值   总被引:2,自引:0,他引:2  
目的 提高心肌断层显像技术对冠心病诊断的准确性和实用性。方法 采用双核素门控心肌断层显像对 10 3例受检者进行检查 ,患者分为冠心病组 (3 7例 )和非冠心病组 (66例 )。静息注射2 0 1Tl和运动高峰注入99Tcm 甲氧基异丁基异腈 (MIBI) ,40min后一次性进行门控双能峰断层采集。分析比较运动和静息的断层图像 ,以及室壁运动、心肌灌注、室壁增厚度和区域射血分数值等 4个功能图像和左室功能参数 :左室射血分数、舒张末期容积和收缩末期容积 (LVEF、EDV和ESV) ,并以不同角度的“双网图”分析各心壁运动情况。有 3 8例在 2周内进行冠状动脉造影。结果 冠心病组检查阳性 94.6% (3 5 / 3 7例 ) ,阴性 5 .4% (2 / 3 7例 ) ;非冠心病组中检查阳性 10 .6% (7/ 66例 ) ,阴性89.4% (5 9/ 66例 )。冠心病组中双核素门控心肌断层显像提示心肌缺血共 48个节段 ,其中有 3 2个在功能图像上出现室壁运动下降和 (或 )区域LVEF值降低 (66.7% )。冠心病组LVEF(% ) ,EDV(mL)和ESV(mL)分别为 5 2 .3 3± 16.2 6,70 .45± 2 8.12和 3 3 .3 5± 18.86,非冠心病组分别为 61.76± 9.3 8,60 .45± 18.18和 2 3 .3 0± 11.0 9,两组之间比较P <0 .0 1(t=2 .96) ,P <0 .0 5 (t =2 .5 5 ) ,P <0 .0 5 (t =2 .67)。其中 3 8例与冠状  相似文献   

8.
目的 对比99Tcm-替曲膦(TF)和99Tcm-MIBI G-MPI的左室心肌灌注及左室心功能参数结果,探讨99 Tcm-TF能否作为临床G-MPI常规显像剂.方法 99Tcm标记TF和MIBI并进行放化纯测定.选取2011年12月至2012年5月间既往健康、排除严重心律不齐及临床拟诊为心肌炎、心肌病的112例受试者(研究经医院伦理委员会批准,患者签署知情同意书),采用简单随机抽样法将其随机分成2组,分别行一日法99Tcm-TF(47例,运动负荷状态下注射显像剂370 MBq,静息状态下注射显像剂740 MBq)G-MPI和两日法99Tcm-MIBI(65例,注射剂量均为555 MBq)G-MPI,所有受试者均于1周内行CAG和UCG检查.利用Cedars定量门控SPECT(QGS)软件获得左室心功能参数,包括LVEF、EDV、ESV、峰充盈率(PFR)、峰射血率(PER)及相位标准差(SD).采用SPSS 17.0软件进行x2检验、两独立样本r检验、配对r检验及直线相关分析.结果 99 Tcm-TF和99Tcm-MIBI放化纯分别为(97.5±0.4)%和(99.1±0.2)%.与CAG结果对比,99Tcm-MIBI心肌灌注结果符合率为90.5%(57/63),99Tcm-TF为88.9%(40/45),两者差异无统计学意义(x2=0.389,P>0.05).99Tcm-TF和99Tcm-MIBIG-MPI获得的左室心功能参数差异也无统计学意义[LVEF:(62.60±±13.56)%与(60.52±7.08)%,r=0.940;EDV:(103.31±17.29) ml与(98.52±19.37) ml,t=1.348;ESV:(41.73±12.69) ml与(46.05±10.81) ml,t=0.851;PER:(2.73±0.67) EDV/s与(2.61±1.04) EDV/s,t =0.725;PFR:(2.13±0.80) EDV/s与(2.07±1.09) EDV/s,t=0.339;相位SD:(5.58±4.16).与(5.97±4.64).,t=0.450,均P>0.05].两者G-MPI获得的左室心功能参数与UCG结果差异无统计学意义[LVEF:(61.39±10.28)%与(62.13±8.51)%,t=0.991;EDV:(100.50±18.61) ml与(101.70±18.34) ml,t=1.806;ESV:(44.25±11.77) ml与(43.94±11.28)ml,t=0.658;均P>0.05],且与UCG结果呈正相关(r=0.673、0.710和0.452,均P<0.05).结论 99Tcm-TF可作为G-MPI显像剂常规用于临床,同时评价左室心肌灌注情况和左室功能.  相似文献   

9.
目的探讨静息门控心肌灌注显像总积分在冠心病诊断中的临床价值。方法回顾性分析43例冠心病患者,所有患者均行门控心肌灌注显像(GMPI),应用ECTbox软件计算左室舒张末期容积(EDV)、收缩末期容积(ESV)、左室射血分数(LVEF)、每搏输出量(SV),利用半定量分析法得出静息灌注总积分SRS,与上述各指标进行相关性分析,根据SRS的结果将患者分为两组(SRS 10分组、SRS≥10分组),比较两组间左心功能参数差异(均为P 0. 05),并比较各指标在男女之间的差异,最后探讨GMPI在冠心病中的诊断价值。结果 SRS 10与SRS≥10两组间左心功能参数具有明显差异,P 0. 01; SRS及IVEF呈显著负相关,r=-0. 710,SRS与EDV、ESV呈显著正相关,相关系数分别为0. 703、0. 764,与SV呈负相关,r=-0. 415,均为P 0. 01;男性受检者EDV,ESV明显高于女性受检者,而LVEF明显低于女性,男女间差异具有显著性(P 0. 01)。结论门控心肌灌注显像SRS与左室功能呈显著负相关。静息门控心肌灌注显像在冠心病(CAD)的诊断及疗效评估有重要价值。  相似文献   

10.
目的 探讨201Tl定量门控心肌灌注体层显像与99mTc-红细胞门控心血池显像测量左心室射血分数(LVEF)的相关性.方法 72例受检者接受201Tl静息门控心肌灌注体层显像,用AUTOQUANT 4.21软件测量LVEF,并与24 h内的静息99mTc-红细胞平衡法门控心血池显像结果进行比较.结果 ①门控心肌灌注体层显像与门控心血池显像测量LVEF值的结果呈明显正相关(r=0.554,P=-0.000),两种方法无统计学差别(t=1.194,P>0.05).②不同疾病组之间两种测量方法无统计学差异(P值均大于0.05).③门控心肌灌注体层显像及门控心血池显像测量的LVEF值分别为(64.68±10.77)%和(62.46±8.99)%,门控心肌灌注体层显像测量的LVEF值要比门控心血池显像高出3.55%.结论 201Tl门控心肌灌注体层显像与99mTc-红细胞门控心血池显像测量LVEF值的相关性好且结果准确,但门控心肌灌注体层显像的LVEF测量值要稍高于门控心血池显像.  相似文献   

11.
BACKGROUND: Rest gated 201Tl images are considered to be of poor count statistics due to lower energy and low photon flux of 201Tl in addition to increased attenuation and low dose that can be administered. We compared the left ventricular ejection fraction (LVEF), end diastolic (EDV) and end systolic volume (ESV) obtained on 4 h gated rest 201Tl myocardial perfusion single photon emission computed tomography (SPECT) with those obtained by two-dimensional echocardiography (2-D ECHO) in patients with known or suspected coronary artery disease (CAD). METHODS: Eighty-two consecutive patients who underwent gated 201Tl stress-rest myocardial perfusion SPECT and 2-D ECHO were studied. The gated thallium images were processed with Siemens e-soft autocardiac processor and LVEF, EDV and ESV were evaluated using Emory Cardiac Toolbox. The same parameters were also assessed on the 2-D ECHO using the modified Simpson method for comparison. RESULTS: Out of 82 rest gated images, one study was excluded because of poor count statistics. In 81 (99%) patients there was good linear correlation with 2-D ECHO values and rest gated 201Tl SPECT images for EDV, ESV and LVEF. Pearson's correlation co-efficient (r value) for EDV, ESV and LVEF between the two methods was 0.78, 0.79 and 0.88, respectively. A Bland-Altman plot showed close agreement with LVEF but not for EDV and ESV. CONCLUSION: These results suggest that the 4 h rest gated 201Tl study gives a reliable value for the LVEF compared to 2-D ECHO and can be used in routine clinical practice.  相似文献   

12.
BACKGROUND: The aims of this study were to assess the degree of postischemic left ventricular (LV) dilatation after adenosine stress and to determine the extent to which LV volumes measured with gated single photon emission computed tomography (SPECT) correspond to those obtained by echocardiography. METHODS: Eight-frame gated SPECT with a 2-day technetium-99m tetrofosmin acquisition protocol was used. End-diastolic (EDV) and end-systolic (ESV) volumes were measured automatically with the quantitative gated SPECT algorithm. Reversible myocardial hypoperfusion was evaluated with a 16-segment, 4-point perfusion score model. LV volumes at rest were also measured with echocardiography by use of the biplane Simpson rule. RESULTS: Twenty-two patients (group 1) showed normal perfusion and normal LV systolic function, whereas 33 patients (group 2) had evident coronary heart disease with reversible hypoperfusion. Patients in group 2 had greater EDV and ESV than those in group 1 both at rest and poststress. A greater reduction in ESV from poststress to rest was seen in group 2, which resulted in a slight increase in ejection fraction for patients in this group. The change in ESV from poststress to rest was significantly influenced by the degree of reversible hypoperfusion and by the change in heart rate from poststress to rest. We found a good correlation between LV volumes measured with gated SPECT and echocardiography. CONCLUSION: LV volume measurements with quantitative gated SPECT are comparable to those obtained with echocardiography. Patients with ischemic heart disease have greater LV volumes than patients with normal perfusion. Exercise-augmented adenosine infusion in patients with ischemic heart disease affects ESV more than EDV. This response is partly modulated by the degree of reversible hypoperfusion and possibly represents a minor degree of poststress stunning.  相似文献   

13.
Several studies have shown the accuracy of gated single photon emission computed tomography (SPECT) using thallium-201 and technetium tracers in the assessment of myocardial perfusion and function. Gated SPECT has been successfully utilized to detect post-stress left ventricular ejection fraction (LVEF) reduction resulting from post-ischemic stunning in patients with coronary obstruction. The aim of this study was to evaluate whether the post-stress LVEF impairment could be related to the post-stress end-systolic ventricular dilation resulting from post-ischemic endocardial stunning. Two hundred and eighty-two consecutive patients were studied by conventional diagnostic 2 day stress/rest gated SPECT following injection of 925 MBq of 99mTc-tetrofosmin using a dual-headed SPECT camera. One hundred and forty-seven of these patients (52%) showed reversible perfusion defects, 69 (24%) permanent defects and the remaining 66 (24%) had normal perfusion. One hundred and thirty-eight of these patients had a history of myocardial infarction (MI) and 19% underwent coronary angiography without an intervening cardiac event. Perfusion was analysed on ungated images using 20 segments scored on a five-point scale (0, normal; 4, no uptake), while wall thickening (WT) was assessed visually on stress/rest end-systolic images using a four-point score (0, normal; 3, absence of WT). LVEF and volumes were calculated using an automatic algorithm. The post-stress and rest ratios were determined for both end-diastolic (EDV) and end-systolic (ESV) volume. Normal values for all these parameters were obtained using data from 149 patients with a low likelihood (<5%) of coronary artery disease (CAD). In 50 of the 147 (34%) of patients with reversible perfusion defects, post-stress LVEF was >5% lower than rest values (stunned group), while the remaining 97 patients did not show a significant LVEF change (group 2A). The percentage of patients who developed exercise-induced angina, the percentage of patients who underwent coronary angiography and the segmental summed perfusion and WT scores were significantly higher in the stunned group compared with group 2A. Only ESV increased significantly post-stress, and this increase occurred only in stunned patients. Both EDV and ESV ratios were significantly higher in the stunned group compared with normal controls (P=0.008 and P<0.000001, respectively) and with the subgroup 2A (P=0.011 and P<10(-12), respectively). The ESV stress/rest ratio correlated significantly with the summed WT difference score by univariate analysis in stunned patients. It can be concluded that the post-stress ESV dilation, obtained by stress/rest gated SPECT, seems to be due to endocardial post-ischemic stunning. The stunned patients showed more severe clinical, angiographic, perfusion and function parameters.  相似文献   

14.
BACKGROUND: The phenomenon of reversible impairment in LV function has been well described and is known as myocardial stunning. OBJECTIVE: Thallium-201 myocardial perfusion gated SPECT was used to evaluate myocardial stunning and its incremental prognostic value in patients with coronary artery disease. PATIENTS AND METHODS: Fifty-six patients (aged 63+/-11 years) with coronary artery disease were included in this study. All subjects underwent exercise thallium scintigraphy. ECG-gated SPECT was obtained both at post-stress (10 minutes after the injection of 111 MBq of thallium at the time of peak exercise) and at rest (180 minutes). The left ventricular ejection fraction (LVEF) and end-systolic and end-diastolic volume (ESV, EDV) were determined by a quantitative gated SPECT (QGS) program. RESULTS: Follow-up was complete in all patients (mean 569 days). The magnitude of the depression of post-stress LVEF relative to the rest LVEF was correlated with the severity of ischemia (p < 0.05). The group with a median LVEF of more than 45% had a significantly higher event-free rate (p < 0.01). CONCLUSION: Assessment of post-stress left ventricular function by gated-SPECT provides incremental prognostic information and is useful in predicting cardiac events in patients with suspected or definite coronary artery disease.  相似文献   

15.
Quantifying transient ischemic dilation using gated SPECT.   总被引:6,自引:0,他引:6  
Transient ischemic dilation (TID) is both a sensitive and a specific indicator of triple-vessel coronary artery disease. This finding, obtained from ungated SPECT images, is the ratio of the average ventricular size after stress compared with rest. With gated SPECT, however, measurements of the end-diastolic volume (EDV) and end-systolic volume (ESV) can be obtained, and the relative contributions of each to the TID ratio may be estimated. The objective of this study was to quantify the relative contributions of the EDV and ESV when correlating an optimized stress-induced volume ratio (SIVR) with myocardial ischemia. METHODS: A retrospective review was made of 422 consecutive patients undergoing gated SPECT myocardial perfusion imaging. Semiquantitative summed stress and rest scores were determined using a 17-segment, 5-point model. The presence of myocardial ischemia was defined as a summed difference score of >or=3 (i.e., myocardial ischemia of >4%). Poststress-to-rest ratios of the EDV, ESV, and left ventricular ejection fraction (LVEF) were correlated with myocardial ischemia. Using a brute force method, relative weights were assigned empirically to the EDV and ESV to calculate an optimized SIVR having the strongest correlation with myocardial ischemia. RESULTS: There was a significant correlation between the presence or absence of ischemia and the ESV ratio (P<0.01), the EDV ratio (P<0.01), and the LVEF ratio (P<0.05). When controlling for age, type of stress, and sex, the strongest correlation was with the ESV ratio. The SIVR most strongly correlated with myocardial ischemia was found to be the stress-to-rest ratio of the (ESVx5.0+EDV). This SIVR was more strongly correlated with myocardial ischemia than the stress-to-rest ESV ratio, EDV ratio, or LVEF ratio. CONCLUSION: Compared with either the ESV or the EDV stress-to-rest ratio alone, the combination of both results in a stronger correlation with myocardial ischemia. The contribution of the ESV was found to be 5 times greater than the contribution of the EDV when determining a SIVR most strongly correlated with stress-induced myocardial perfusion defects.  相似文献   

16.
Left ventricular function is an important prognostic indicator in patients with coronary artery disease. The electrocardiogram gated, myocardial, single photon emission tomography (SPECT) program is coming into wide use. This program permits measurement of end diastolic volume, end systolic volume, and ejection fraction. This study was designed to show whether the measurement of ejection fraction by using (99c)Tc tetrofosmin gated SPECT at rest could give additional information to the interpretation of perfusion. Exercise 99mTc tetrofosmin SPECT and gated (99c)Tc tetrofosmin SPECT at rest were performed in 33 patients with or suspected of having coronary artery disease. Left ventricular ejection fraction was calculated from reconstructed gated SPECT at rest with a software quantitative gated SPECT. The results showed a poor correlation between segmental ejection fraction and segmental perfusion in stress and rest. There was an increasing probability of reversibility as the ejection fraction increased, while there was a greater chance of a fixed defect as the ejection fraction decreased. It is concluded that gated SPECT using (99c)Tc tetrofosmin provides clinically satisfactory functional data that, in combination with the perfusion information, will improve diagnostic and prognostic accuracy without an increase in cost or radiation dose to patients.  相似文献   

17.
目的探讨GE VG/Hawkeye单光子发射断层扫描仪(SPECT)随机携带3种左室射血分数算法对静息态99Tcm-MIBI门控心肌断层显像测定左室射血分数(LVEF)的临床应用价值。方法对103例、6组受检者进行门控心肌断层显像,使用3种算法分别测定3组左室射血分数(LVEF0、LVEF1、LVEF2),分别与M型超声心动获得的LVEF(UEF)进行对比分析。结果(1)103例受检者图像显影清晰;(2)根据不同算法获得门控心肌断层显像3组LVEF值(EF0、EF1、EF2)与超声心动图检查结果(UEF)均具有显著相关性(r0=0.948、r1=0.937、r2=0.940),其中EF0与UEF一致性较好;(3)静息态99Tcm-MIBI门控心肌断层显像测定左室射血分数可重复性好(P<0.05);(4)各组间t检验示:心肌缺血组、心梗组及扩张型心肌病组与正常组比较均存在显著性差异(P<0.05);高血压组、心肌炎组、扩张型心肌病和心肌缺血组比较均存在显著性差异(P<0.05);高血压组、心肌炎组、扩张型心肌病组与心梗组比较均存在显著性差异(P<0.05);扩张性心肌病组与心肌炎组比较亦存在显著性差异(P<0.05)。结论静息态99Tcm-MIBI静息态门控心肌断层显像测定左心室射血分数(LVEF)可靠,3种算法中以第一种最好,具有较好的临床应用价值。  相似文献   

18.
The purpose of this study was to compare left ventricular (LV) volume and ejection fraction (LVEF) measurements obtained with electrocardiographic gated single-photon emission computed tomographic (SPECT) myocardial perfusion imaging (GS-MPI) with those obtained with gated SPECT cardiac blood-pool imaging (GS-pool). Fifteen patients underwent GS-MPI with technetium-99m-tetrofosmin and GS-pool with technetium-99m-erythrocyte, within a mean interval of 8 +/- 3 days. Eight patients had suspected dilated cardiomyopathy and seven patients had angiographically significant coronary artery disease. End-diastolic volume (EDV), end-systolic volume (ESV) and LVEF measurements were estimated from GS-MPI images by means of Cedars-Sinai automatic quantitative program and from GS-pool images by the threshold technique. Mean differences between GS-MPI and GS-pool in EDV, ESV and LVEF measurements were -2.8 +/- 10.5 ml [95% confidence interval (CI): -8.6 +/- 3.0 ml], 2.6 +/- 7.3 ml (CI: -1.4 +/- 6.6 ml) and -2.3 +/- 5.1% (CI: -5.1 +/- 0.6%), respectively. No significant difference in the mean differences from 0 was found for EDV, ESV or LVEF measurements. Bland-Altman plots revealed no trend over the measured LV volumes and LVEF. For all parameters, regression lines approximated lines of identity. The excellent agreement between GS-MPI and GS-pool measurements suggests that, for estimation of LV volumes and LVEF, these two techniques may be used interchangeably and measurements by one method can serve as a reference for the other.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号