首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 31 毫秒
1.
目的 分析心血管疾病患者在介入诊疗过程中的辐射剂量,探讨其预防措施.方法 抽取用SIEMENS Aritis Zee Floor DSA介入诊疗的心血管疾病患者186例,记录随机配备的辐射检测系统显示的总辐射时间(T)、剂量面积乘积(DAP)、累积剂量(CD),由DAP估算有效剂量(ED),由CD估算最高皮肤剂量值(PSD).结果 患者所受T为0.9~71.2 min,平均10.5 min,>30 min的9例(4.8%);ED为0.11~282.9 mSv,平均32.2 mSv,>100 mSv的10例(5.4%);1 Gy<PSD (1/2CD)≤3Gy的40例(21.5%),PSD(1/2CD)>3 Gy的4例(2.2%);1 Gy< PSD(4/5CD)≤3Gy的53例(28.5%),PSD(4/5CD)>3Gy的14例(7.5%).T与PSD(1/2 CD)、PSD(4/5CD)、ED在置信度(双侧)为0.01时显著相关.结论 23.7%~36.0%心血管介入患者可因累积剂量导致严重的皮肤损伤,5.4%心血管介入患者有显著的致癌危险.  相似文献   

2.
心脏介入患者受照剂量研究   总被引:4,自引:2,他引:2  
目的 调查我院心脏介入诊疗过程中患者受照剂量分布和剂量参考水平,并分析各种剂量参数如皮肤峰值剂量(PSD)和剂量面积乘积(DAP)之间的相关性.方法 对135例患者的剂量数据进行分析研究,其中接受冠状动脉造影(CAG)患者84例,接受经皮心脏介入(PCI)患者51例.记录每例患者DAP值、参考点累计剂量值(CD)以及透视时间,总采集图像幅数.采用热释光剂量片(TLD)矩阵测量患者皮肤剂量.TLD矩阵大小为10行9列,行间隔5 cm,列间隔4 cm.结果 对于PCI,DAP均值为7946.91μGym2;CD均值为1395.3 mGy,平均透视时间10.9 min,平均采集945幅.PSD范围为38.91~184.79mGy.DAP与PSD的相关性为0.54,PSD与CD的相关性为0.53.对于CAG,DAP均值为2690.84 μGym2;CD均值为431.6 mGy,平均透视时间为2.9 min,平均采集544幅.PSD范围26.18~120.37 mGy.DAP与PSD的相关性为0.52,PSD与CD的相关性为0.45.结论 患者所受皮肤剂量峰值低于所致皮肤损伤辐射阈值(2 Gy).各种辐射剂量参数(如DAP,CD和透视时间等)的结果与其他学者的研究结果相仿.从结果可以看出PSD与DAP、CD等参数相关性较差,因此基于这些数据对个体皮肤峰值剂量进行估算的方法较不科学,需要对其进一步研究.  相似文献   

3.
目的分析200例急性动脉综合征介入治疗患者受照射剂量,探讨病变部位、狭窄程度、年龄和手术医生等因素对辐射剂量的影响。方法回顾分析我院200例急性动脉综合征行介入治疗(PCI)患者所记录的剂量资料,随机配置的剂量检测系统记录剂量面积乘积(DAP)和累计剂量(CD),根据DAP值估算有效剂量(ED)。根据血管病变受累程度分为单一病变和复杂病变以及患者年龄分组(小于40岁组,40~60岁组及大于60岁组)、左右侧冠状动脉和第一操作医生对患者受辐射剂量的影响。结果①本次收录200例行PCI术者累积剂量CD值191~5524 mGy,平均值(1157±781)mGy;剂量面积乘积DAP值(12714~417228)mGy·cm^2,平均值(100690±63896)mGy.cm^2;有效剂量ED范围1.119~58.411 mSv,平均值(14±9)mSv。②单一病变相比复杂病变辐射剂量少,CD值、DAP值、ED值差异有统计学意义(P<0.05)。③左侧冠状动脉大于右侧冠状动脉(P<0.05)。④3个年龄组间各个剂量值方差分析差异无统计学意义(P>0.05)。⑤2组不同年资操作医生患者所受剂量差异无统计学意义(P>0.05)。结论急性冠状动脉综合征PCI术患者接受辐射剂量差异较大,主要与病变本身(包括病变部位和累计范围及变异等)因素相关。  相似文献   

4.
目的:研究冠心病患者介入诊疗中DSA设备显示的实时辐射剂量率,为医务人员合理控制辐射剂量提供依据。方法随机抽取2014年9月采用美国通用公司DSA机介入诊疗的冠心病患者30例,对术中DSA机由透视模式转换为电影模式时各自序列显示的辐射剂量率进行对比分析。结果透视辐射剂量率为18.5~212.0 mGy/min,均值为(114.7±42.1) mGy/min;电影辐射剂量率为216~1691 mGy/min,均值为(970.1±298.4) mGy/min。透视与电影辐射剂量率总体均值之比为1︰8.5。数字平板探测器面积越大,辐射剂量率均值越大,电影辐射剂量率均值较透视辐射剂量率均值增高趋势越明显;透视辐射剂量率均值较电影辐射剂量率均值低,差异显著。结论医务人员在冠心病介入诊疗中应合理选择 DSA 设备类型,密切观察动态实时显示的辐射剂量率,及时调整检查模式及可控参数,即刻评估可能致患者放射损伤的剂量水平,合理控制辐射剂量,以降低电离辐射对人体健康产生的辐射效应。  相似文献   

5.
目的以心血管介入术后采集空气比释动能(reference air kerma,AK)值和剂量面积乘积(dose-area product,DAP)值数据为依据,分析术中透视时间报警设置作为心血管介入手术辐射剂量的监测和警示工具的可行性。方法回顾性分析2016年11月至2018年1月上海长海医院736例冠状动脉造影术(CAG)和经皮冠状动脉治疗术(PCI)病例,收集术中透视时间、AK和DAP数据资料。德国西门子成像设备分组(Ceiling系统和Biplane系统)和手术类型分组(CAG和PCI),对辐射剂量数据进行比较,以及对心血管介入手术AK和DAP值与透视时间数据采用Spearman检验解析相关性。结果Ceiling和Biplane成像系统中手术透视时间为(8.9±7.8)和(8.6±7.3)min,透视AK均值和DAP均值分别为(472±474)、(510±509)mGy、(4548±4085)和(4255±3781)μGy·m^2,术中总(透视+造影)AK和DAP均值为(703±595)、(733±614)mGy、(6253±4938)和(5681±4432)μGy·m^2。CAG与PCI术中透视时间均值分别为(2.4±0.9)和(15.7±4.9)min。PCI透视辐射剂量(AK和DAP)与术中总辐射剂量比值分别为74%和78%。心血管介入手术中透视时间与AK值(r=0.822)和DAP值(r=0.844)都呈高度相关性(P<0.001)。结论透视采集辐射剂量是心血管介入手术中辐射剂量的主要来源,辐射剂量随透视时间延长而增加,透视时间监测和报警设置在心血管介入临床应用中作为术中辐射防护工具有一定的参考和警示价值。  相似文献   

6.
心血管病介入操作时患者受照剂量研究   总被引:1,自引:1,他引:0       下载免费PDF全文
目的 对心血管介入手术中患者所受辐射剂量及与辐射剂量相关的指标进行采集和分析,为改善患者的辐射防护提供依据.方法 对在省属三级甲等医院进行的26例完整的心血管介入手术的患者进行临床数据采集,按手术类别分成冠状动脉血管造影术(CA)及行冠状动脉血管造影术(CA)后继续行经皮穿刺腔内冠状动脉成形术(PTCA)两组,采用TLD个人剂量计照射野矩阵测量法,检测患者荧光照射时间、入射皮肤剂量(ESD)、最高皮肤剂量(PSD)、剂量-面积乘积(DAP)等指标,用TLD测量在模拟心血管手术条件下体模器官剂量.结果 荧光透视时间为(17.7±15.6)min,范围为0.80~42.4 min;ESD范围为(159±138)mGy,4.40~459 mGy;PSD范围为(769±705)mGy,22.6~2.43×103mGy.CA+PTCA组的荧光照射时间、ESD、PSD均大于CA组,差异有统计学意义.最大皮肤受照剂量与透视时间有较好的相关性(r=0.84,P<0.01).结论 心血管病放射性介入操作时,可通过透视时间来估算最大皮肤受照剂量.
Abstract:
Objective To collect and analyze the radiation dose to patients in cardiovascular interventional procedures and the radiation dose-related indicators,in order to provide a basis for improving radiation protection of patients.MethodsThe clinical data of 26 cases of complete cardiovascular interventional procedures was collected in the municipal Grade A Class Three hospitals,including coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA),and the patient-received radiation doses and other related factors was studied.TLD personal dosimeter radiation field matrix method was used to measure fluorescence time,the entrance skin dose (ESD),the peak skin dose (PSD),dosearea product (DAP) and other indicators.TLD was used to measure the organ dose of the phantom under the cardiovascular interventional procedure condition.ResultsThe fluoroscopy time was (17.7 ±15.6) min during the range of 0.80-42.4 min.The average entrance skin dose (ESD) was (159 ± 138)mGy during the range of 4.40-459 mGy.The peak skin dose (PSD) was (769 ± 705) mGy during the range of 22.6 - 2.43 × 103mGy.The fluorescence time,entrance skin dose (ESD) ,peak skin dose (PSD) of the group CA + PTCA are greater than the group CA and the difference has statistical significan.The peak skin dose and the fluoroscopy time have good linear correlation (r = 0.84,P < 0.01 ).Conclusion The peak skin dose the patient received in cardiovascular interventional radiological operation can be estimated through the fluoroscopy time.  相似文献   

7.
目的:测量出血性脑血管病在介入放射学诊疗过程中患者及介入医生所受到的X线辐射剂量,分析探讨影响X线辐射剂量的因素及其减低剂量的途径和方法.方法:应用热释光测量法对我院介入中心近期120例出血性脑血管病进行介入放射学检查和(或)介入治疗时患者及介入医生辐射剂量测量.结果:出血性脑血管病患者行全脑血管造影时患者皮肤剂量范围在0.013~4.032 Gy,介入医生所受剂量范围在0.113~1.601 mGy;行栓塞治疗时患者皮肤剂量范围在2.231~10.868 Gy,介入医生所受剂量范围在0.307~2.548 mLGy.结论:全脑血管造影是诊断出血性脑血管病的金标准,介入治疗是治疗脑血管病的重要而有效的方法之一,但患者及介入医生所受的X线辐射剂量很大,因此应该采取有效的防护措施来减低X线辐射剂量.  相似文献   

8.
目的 采用胶片法对进行心血管介入手术中患者所受峰值皮肤剂量(PSD)进行测量研究,包括冠状动脉血管造影术(CA)和经皮穿刺腔内冠状动脉成形术(PTCA)。方法 选用Gafchromic XR-RV3胶片在两家医院进行患者峰值皮肤剂量的测量。手术时将胶片放在患者身下的诊视床上。记录手术中监视器上显示的kV、mA、透视时间、剂量面积乘积(DAP)、参考点累积剂量等相关信息。采用Epson V750平板扫描仪对胶片进行分析扫描及分析,选用FilmQA软件分别测量图像的红、绿、蓝三色通道的像素值,使用红通道数据计算患者的 PSD。对PSD与设备显示参数进行相关分析,对相关的变量进行多元线性回归分析。结果 共测量CA手术26例,CA+PTCA手术19例。CA手术中,透视时间最高为17.62 min,累积剂量和DAP最大分别为1 498.50 mGy和109.68 Gy ·cm2,PSD最大为361.20 mGy。CA+PTCA手术中,曝光时间最长为64.48 min,累积剂量和DAP最大分别为6 976.20 mGy和5 336.00 Gy ·cm2,17例患者的PSD在1 Gy以内,1例患者PSD在1~2 Gy之间,1例患者PSD超出了发生皮肤损伤2 Gy的阈值,达到了2 195.70 mGy。CA程序中,患者PSD与DAP相关(R2=0.815,P<0.05),CA+PTCA程序中,患者PSD与累积剂量相关(R2=0.916,P<0.05)。结论 心脏介入放射学程序中部分患者的PSD会超出ICRP建议的发生皮肤确定性效应的2 Gy阈值。DSA设备上显示的剂量相关的参数,只能粗略估算患者PSD的大小。使用XR-RV3胶片精确测量介入手术中患者的峰值皮肤剂量是一种非常快捷、有效的方法。  相似文献   

9.
【摘要】 目的 测量输卵管介入栓塞术中患者所接受的X线辐射剂量,并评估其对后续体外受精-胚胎移植(IVF-ET)的影响。方法 选取50例双侧输卵管积水患者作为研究组,50例双侧输卵管近端阻塞的患者作为对照组。研究组在先行介入栓塞术处理输卵管积水,术中分别在患者的眉心、颈前正中、胸骨柄、背部左右12肋缘中点、阴道后穹隆、骶尾部皮肤和盆腔的腹侧相对应皮肤,共7个点放置热释光剂量计, 测量患者各部位接受的辐射剂量,并记录患者介入栓塞术中透视时间。统计研究组和对照组患者在IVF-ET过程中的获卵数、受精率、优胚率和临床妊娠率等指标。结果 两组的获卵数、受精率、优胚率和临床妊娠率等指标比较差异均无统计学意义(P>0.05),测量透视时间(6.37±3.88) min,辐射剂量眉心(0.20±0.07) mGy、颈前正中(防护后)0.025(0.00,0.07) mGy、胸骨柄(防护后)0.035(0.00,0.06) mGy、背部左右12肋缘中点(0.55±0.28) mGy、阴道后穹隆(1.28±0.75) mGy、骶尾部皮肤(11.13±8.01) mGy、盆腔的腹侧相对应皮肤(0.75±0.29) mGy。结论 介入输卵管栓塞术中患者所接受X线辐射在安全范围内,是一种安全的方法,适当的防护和熟练的操作可有效减少辐射剂量。  相似文献   

10.
目的 统计血管造影受检者每次检查所受辐射剂量值及影响辐射剂量的相关因素,为分析、评估放射诊疗风险提供数据参考。方法 收集107例受检者检查时在线记录的全部辐射剂量值及其与剂量相关的技术参数值,按照检查区域头部、腹部和心脏进行分类,统计每例受检者的总透视时间、透视累积剂量面积乘积(DAP)、透视累积皮肤入射剂量(ESD),计算透视剂量率;统计每例受检者的造影曝光次数、造影曝光时间、采集帧频率,以及造影累积剂量面积乘积和造影累积皮肤入射剂量;统计每例受检者的透视加造影的总累积剂量面积乘积和总累积皮肤入射剂量。对所有数据分门别类进行相应的对比分析。结果 冠状动脉造影+介入,ESD为(22 285.5±18 682.7)μGy·m2,DAP为(2 942.1±2 557.3)mGy;头部血管造影DAP为(25 929.6±8 302.7)μGy ·m2,DAP为(1 288.8±682.3)mGy;腹部血管造影,DAP为(12 129.7±10 646.1)μGy·m2,ESD为(730.1±584.7)mGy。结论 血管造影受检者所受总累积剂量,冠状动脉造影相对最高,其次是头部血管造影,腹部血管造影相对较低。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号