This in vitro study evaluated the effect of rebonding on microleakage of a resin composite, a condensable resin and two polyacid-modified resin composite restorations. Standardized cylindrical Class V dentin cavities were prepared on the buccal root surfaces of 240 extracted bovine incisive teeth. The prepared teeth were randomly assigned to four groups of 60 teeth and restored with the following restorative systems: I--(ZS) Z100/Scotchbond Multi-Purpose Plus; II--(SS) Solitaire/Solid Bond; III--(FS) Freedom/Stae; IV--(FSB) F200/Single Bond. Thirty teeth of each group were rebonded with a low-viscosity resin (Fortify/BISCO), according to the manufacturer's instructions. The remaining teeth received no treatment. All teeth were thermocycled for 5,000 cycles and brushed by hand three times a day for 10 days using a toothbrush and a slurry of dentifrice and water. Specimens were stained in a 2% methylene blue solution and longitudinally sectioned with diamond disks. Microleakage was scored on a scale of 0 to 3. The Kruskal-Wallis test showed statistically significant differences among the groups (h=156.54; alpha<0.05). Pairwise comparison by means of the least significant difference showed that (SS) and (FS) with or without rebonding were not statistically different from each other. These groups showed the highest microleakage differences from (ZS) and (FSB) with or without rebonding. (ZS) with rebonding showed the lowest microleakage that was not statistically different from (ZS) without rebonding and (FSB) with rebonding.  相似文献   

2.
Marginal quality and microleakage of adhesive class V restorations   总被引:2,自引:0,他引:2  
OBJECTIVES: The aim of this in vitro study was to determine the marginal quality and microleakage of composite resin class V restorations. METHODS: Standardized mixed class V cavities (diameter: 4mm, depth: 2mm) with half of the finish lines limited within dentin were cut in 90 freshly extracted human molars and randomly assigned to nine groups (n=10). After etching enamel and dentin, the cavities were restored with nine different restorative systems (Syntac Sprint/Tetric Ceram=SS, Syntac Single-Component/Tetric Ceram=SC, Onestep/Aeliteflo=OS, Aquaprep+Onestep/Aeliteflo=OA, Prime & Bond 2.1/TPH=PB, Optibond Solo/Prodigy=OP, Singlebond/Z100=SB, Tenure Quik/Marathon=TQ, Solobond M/Arabesk=SM) using a wet-bonding procedure. After finishing and polishing, the teeth were stored for 24h in distilled water at 37 degrees C before they were subjected to thermocycling (5/55 degrees C, 1000x). Epoxy replicas were made for margin analysis in the SEM. Specimens were stained in methylene blue, sectioned, and evaluated for microleakage. Dye penetration was scored on a 0-3 ordinal scale. RESULTS: Statistical analysis (Kruskal-Wallis H-test, Mann-Whitney U-test) revealed significant differences (P<0.05) among the groups at dentin and enamel margins for the microleakage scores as well as for the results of the quantitative SEM margin analysis. SC revealed a significantly higher percentage of perfect margins in the SEM than OS and SM in enamel and dentin, respectively. OA exhibited significantly more leakage in enamel than all other groups. CONCLUSIONS: None of the tested restorative systems achieved a perfect seal in dentin and enamel of mixed class V cavities. Marginal quality and sealing ability of adhesive systems to dentin, using a wet-bonding procedure, is still inferior compared with enamel margins.  相似文献   

3.
4.
5.
The aim of this study was to evaluate the effect of three different curing units on microleakage of class V composite restorations. Class V cavities were prepared on the buccal surfaces of 45 extracted premolar teeth. The teeth were randomly divided into three groups of 15 each. A conventional halogen curing unit (Hilux 350), a high intensity halogen curing unit (Optilux 501) and plasma arc curing unit (Power Pac) were used to polymerize composite resin (Vitalesence). After restoration, the teeth were thermocycled for 100 cycles between 5 degrees and 55 degrees C using a dwell time of 30 s and exposed to a dye. Results showed that there was no significant difference among three different curing units (P > 0.05), however the microleakage at the dentin margins was greater than the enamel margins (P < 0.05). Clinical relevance: Plasma arc curing or fast halogen units cure composite materials at a faster rate than conventional curing units because of the high light intensity. High intensity halogen curing units and plasma arc curing units might be useful alternatives in composite polymerization. Therefore, these units are suggested for clinical use to save chair side time.  相似文献   

6.
7.
8.
可流动复合树脂充填楔状缺损的体外微渗漏研究   总被引:3,自引:1,他引:2  
陈晨  吴友农  吴红霞 《口腔医学》2005,25(2):100-102
目的 研究可流动复合树脂充填楔状缺损离体牙模型的边缘微渗漏情况。方法 选择因正畸拔除的上颌前磨牙2 4个,于颊侧颈部釉牙骨质界处备V型洞后,随机分为3组,分别采用Aelieteflo可流动复合树脂,DyractAP复合体,GICTYPEII化学固化玻璃离子进行充填。经力循环、热循环后,2 %亚甲基蓝染色2 4h ,将每个牙齿自颊舌向沿长轴连续切3片。体视显微镜放大4 0倍观察充填体边缘染液渗漏情况。结果 3组间充填体微渗率差异有显著性(P <0 .0 0 1) ,以Aelieteflo材料的边缘微渗率最低(P <0 .0 5 )。3组牙合侧壁与龈侧壁微渗率间差异无显著性(P =0 .2 6 3)。结论 可流动复合树脂用于楔状缺损充填可以获得较好的边缘封闭性。  相似文献   

9.
This in vitro study investigated the microleakage of flowable resin composite as a restorative material and as a liner (either light cured separately or co-cured with hybrid resin composite) in Class V cavities. A light-cured hybrid resin composite was used as a control. Twenty extracted human premolars were prepared with standardized Class V cavity outlines on the buccal and lingual surfaces. The occlusal margin of the cavities was on enamel and the gingival margin was on dentin. One bottle adhesive system (Single Bond) was used after etching enamel and dentin with 34.5% phosphoric acid for 15 seconds. The cavities were randomly divided into four groups of 10 each and restored according to the manufacturers' instructions: Group I-Hybrid resin composite (Z100); Group II-Flowable resin composite (Filtek Flow); Group III-Flowable resin composite (Filtek Flow)+Hybrid resin composite (Z100); light cured separately; Group IV-Flowable resin composite (Filtek Flow)+Hybrid resin composite (Z100); co-cured. The samples were thermocycled 200 times with a 30-second dwell time. They were then immersed in a 0.5% basic fuchsin solution for 24 hours, sectioned and analyzed by stereomicroscopy. The degree of dye penetration was recorded and analyzed with the Kruskal-Wallis and Mann-Whitney U tests. The results of this study indicate that there was no leakage at the occlusal margin for either restoration. Statistically significant differences were found among the groups at the gingival margin. No statistically significant difference was observed between the occlusal and gingival margins except in Group IV. The combination of flowable resin composite and hybrid composite light cured separately yielded the best result in this study. The most leakage was observed when this combination was co-cured. The resistance to microleakage of flowable resin composite as a restorative material is similar to that of hybrid resin composite.  相似文献   

10.
11.
12.
AIM: The purpose of this study was to investigate the effect of polishing systems on the microleakage of a nanofill, a nanohybrid, and a microhybrid composite in Class V cavities. METHODS AND MATERIALS: Preparations were made at the cemento-enamel junction (CEJ) of 36 extracted human premolars. The teeth were randomly divided into three groups and restored with new resin composites according to the manufacturers' instructions as follows: Group 1, Filtek Supreme & Single Bond; Group 2, Grandio & Solobond; and Group 3, Artemis & Excite. The restorations were finished with diamond finishing burs. The restored/finished teeth were randomly divided into two groups and polished using the following systems: Super-Snap (Al2O2 coated, abrasive disc system, fine grit, and extra fine grit) and Astropol/Astrobrush (silicon-based abrasive polisher point and polisher brush). All specimens were thermocycled 1000 times with a 10 second dwell time. They were immersed in 0.5% aqueous basic fuchsin dye for 24 hours and then sectioned buccal-lingual-longitudinally through the center of both restorations of each tooth and evaluated under a stereomicroscope at 30X magnification. The degree of dye penetration was quantified. RESULT: No significant difference in leakage scores was observed in enamel margins (p=0.456, Kruskall Wallis test), but dentin margins were significantly affected by the different polishing systems (p=0.037, Kruskall Wallis test). The lower leakage scores were recorded for Astropol/Astrobrush polishing systems. The nanofill composite showed the least leakage among the test groups in this study. The most leakage was observed in nanohybrid composite resin (p<0.05, Mann Whitney U test). CONCLUSIONS: Under the conditions of this in vitro study: the microleakage resistance of composites at enamel margins is not significantly affected by the different polishing systems; the lowest leakage scores were recorded for Astropol/Astrobrush polishing techniques in different types of composites; and the ranking of the composite materials from most to least leakage at the dentin margins according to polishing techniques was Grandio >Artemis > Filtek Supreme.  相似文献   

13.
BACKGROUND: Polymerisation shrinkage and the associated stress on composite resins and surrounding structures have been regarded as a major cause of leakage and clinical failures in modern polymer restorations. The purpose of this study was to investigate the effect of an additional flowable compomer layer on the microleakage of Class V dental cavities, which were further filled with a compomer. METHOD: Cavities (32) were prepared in human premolars, conditioned with a non-rinsing agent (Prime & Bond NRC) and treated with the bonding agent (Prime & Bond NT). Sixteen of these cavities were then lined with a layer of flowable compomer (Dyract Flow, approximately 0.5 mm) and further filled with Dyract AP. The other 16 cavities were filled without the flowable compomer. The specimens were thermo-cycled in a 0.5% basic fuchsin solution, sectioned and evaluated for dye penetration using a scoring system of 0 to 4. RESULTS: Lower microleakage values were found at the enamel as well as at the dentine sides when a layer of Dyract Flow was used as a liner. Furthermore, significantly (p < 0.05) lower microleakage was found in enamel than in dentine for both layered and unlayered restorations. CONCLUSION: It can be concluded that a layer of flowable compomer (i.e. Dyract Flow) in a cavity under a compomer may be recommended to improve the marginal seal of a restoration.  相似文献   

14.
STATEMENT OF THE PROBLEM: Microleakage is a major factor contributing to the occurrence of secondary carious lesions around composite restorations. PURPOSE OF STUDY: This in vitro study investigated the effect of thermocycling on microleakage of several composite Class V restorations. MATERIAL AND METHODS: One hundred twenty molars were randomly distributed into 6 groups of 20 teeth. Class V preparations were made in the buccal and lingual surfaces of each tooth and restored in bulk by use of 6 composites (Arabesk, Silux-Plus, Solitaire 2, Durafill VS, Charisma, and Renew) according to the manufacturers' recommendations. The teeth were stored in distilled water at room temperature for 24 hours. The teeth in each group were divided randomly into 2 subgroups: (a) thermocycled for 500 cycles between 5 degrees and 55 degrees C with a dwell time of 30 seconds, (b) no thermocycling treatment. All restored teeth were immersed in 1% methylene blue dye for 4 hours and sectioned buccolingually with a diamond wheel. Dye penetration was scored by use of a stereomicroscope at original magnification x4. The generalized linear models statistical analysis was used (alpha=.05). RESULTS: The preparation margins (enamel/dentin) and thermocycling had a significant effect on microleakage (P=.0351, P<.0001, respectively); the type of material had no significant effect (P=.1689). CONCLUSIONS: Thermocycling significantly increased the microleakage (P<.0001). The overall microleakage at the enamel margins was significantly less than at the dentinal margins (P=.0351).  相似文献   

15.
16.
This in vitro study evaluated the influence of two flowable resin composites on marginal microleakage and internal voids in Class II composite restorations with the margins below the cementoenamel junction (CEJ). Class II cavities randomly divided into four groups: Group I-Filtek with Filtek Flow lining; Group II-Filtek; Group III-Tetric Ceram with Tetric Flow lining; Group IV-Tetric Ceram. After thermocycling tests (5-60 x 1500) and dye soaking, the teeth were sectioned in a mesiodistal direction along their longitudinal axis. Gingival-marginal microleakage and internal voids in three separate portions of the restoration (interface, cervical and occlusal voids) were observed with a microscope. Statistical analyses indicated that the use of flowable resin composites (Groups I and III) provided a reduction in marginal microleakage and a reduction in some parts of the internal voids or total voids (p<0.05). The condensable material (Filtek) in combination with the flowable liner showed fewer voids (interface, occlusal, total) than the hybrid resin (Tetric) (p<0.05). There was a correlation between the number of internal voids or total voids and the marginal microleakage (p<0.05). It was concluded that a composite lining in a Class II resin composite with margins below the cementoenamel junction may reduce marginal microleakage and voids in the interface and the total number of voids in the restoration.  相似文献   

17.
18.
OBJECTIVE: The aim of this study was to compare the behavior of two new, low-shrinkage hybrid composites (Aelite LS and Inten-S) with a microfilled (Heliomolar) and a hybrid composite (Filtek Z250), in terms of polymerization contraction stress and microleakage. METHODS: Maximum contraction stress after 10 min was recorded in a "tensilometer", using a C-factor (C) of 2.5 and energy density of 26 J/cm(2). For the microleakage test, cylindrical cavities with enamel margins prepared in bovine incisors (4 mm diameter, 1.5 mm depth, C = 2.5) were restored in bulk, applying the same energy density used in the contraction stress test. After immersion in 0.5% methylene blue for 4 h, specimens were sectioned twice, perpendicularly, and the highest dye penetration score was recorded. Contraction stress results were analyzed by one-way ANOVA/Tukey's test and microleakage was analyzed by Kruskal-Wallis test. Regression analysis between the two variables was also performed. RESULTS: Aelite LS showed significantly higher stress than the other composites tested. Inten-S and Filtek Z250 had similar stress levels, statistically higher than Heliomolar. In the microleakage test, a significant difference was observed between Aelite LS and Heliomolar only. Regression analysis showed a good linear correlation between the two variables (R2(adjusted) = 0.811). CONCLUSIONS: The low-shrinkage materials exhibited contraction stress values similar or higher than the hybrid composite. A direct relationship between contraction stress values and microleakage for the composites evaluated was verified. SIGNIFICANCE: The low-shrinkage composites tested did not seem to represent an improvement in terms of reducing contraction stress or microleakage.  相似文献   

19.
This study assessed in vitro marginal leakage of class V cavities prepared by turbine and Er:YAG laser and restored with different materials. Sixty cavities with enamel and dentine margins were prepared and assigned to six groups: I, II, III by turbine and IV, V, VI by Er:YAG laser. The following restorative systems were used: groups I and IV: Bond 1 + Alert; II and V: Fuji II LC; III and VI: SBMP + Dispersalloy. After finishing, specimens were thermocycled for 8 h and 45 min (500 cycles), isolated, immersed in a 0.2% Rhodamine B solution, sectioned oro-facially and analysed for leakage. The dye penetration means (%) were: occlusal I: 10.09 (+/- 21.28), II: 3.25 (+/- 10.27), III: 0, IV: 41.77 (+/- 42.48), V: 23.37 (+/- 33.79), VI: 12.66 (+/- 24.06); cervical I: 16.49 (+/- 26.67), II: 4.34 (+/- 13.71), III: 0, IV: 37.71 (+/- 30.47), V: 39.56 (+/- 43.35) and VI: 72.53 (+/- 37.79). The use of Er:YAG laser for cavity preparation yielded higher degree of marginal leakage, as compared with the use of conventional air-turbine. The enamel interface provided better marginal sealing, comparing with dentine/cementum margin. As to the cavity preparation device (i.e. laser or bur), the analysis of the results showed that bonded amalgam and Fuji II LC provided less infiltration, than Alert. On the other hand, for lased cavities, Alert provided the best results, similar to those of Fuji II LC and superior to those reached by bonded amalgam.  相似文献   

20.
目的 研究比较Er, Cr: YSGG激光预备与传统牙钻预备离体牙V类洞对光固化复合树脂边缘微渗漏的影响.方法 于2007年3月至7月,在中国医科大学实验设备处和中国医科大学口腔医学院中心实验室,将30颗离体前磨牙随机分为3组制备V类洞:牙钻预备加37%磷酸处理组,单纯激光预备组,激光预备加37%磷酸处理组,每组l0颗牙.经冷热循环染色后,采用染料渗入和扫描电镜方法 观察充填体微渗漏情况.结果 壁及龈壁处,染料渗入结果 显示,牙钻预备加37%磷酸处理组的染料渗入评分最小,与其他两组比较差异有统计学意义(P<0.05),而单纯激光预备组与激光加37%磷酸处理组之间差异无统计学意义.充填体边缘微缝隙宽度的结果 显示,单纯激光预备组的边缘微缝隙宽度最大,与其他两组比较差异有统计学意义(P<0.05),而牙钻预备加37%磷酸处理组与激光预备加37%磷酸处理组之间差异无统计学意义.结论 Er, Cr: YSGG激光预备处理V类洞不能增加光固化复合树脂与牙体组织的结合,减少微渗漏的发生;而应用激光加37%磷酸可以取代传统牙钻加37%磷酸进行窝洞预备.Er, Cr: YSGG激光预备离体牙V类洞对光固化复合树脂边缘微渗漏的影响研究还有待于继续进行.  相似文献   