1.
Computational fluid dynamics (CFD) technology was applied to predict the flow patterns in the authors' streamlined blood pump and an American bio-pump with straight vanes and shroud, respectively. Meanwhile, haemolysis comparative tests of the two pumps were performed to verify the theoretical analysis. The results revealed that the flow patterns in the streamlined impeller are coincident with its logarithmic vanes and parabolic shroud, and there is neither separate flow nor impact in the authors' pump. In the bio-pump, the main flow has the form of logarithmic spiral in vertical section and parabola in cross section, thus there are both stagnation and swirl between the main flow and the straight vanes and shroud. Haemolysis comparative tests demonstrated that the authors' pump has an index of haemolysis of 0.030, less than that of the bio-pump (0.065).  相似文献   

2.
Background: In 1839, Earnshaw proved theoretically that it is impossible to achieve a stable equilibrium with a pure permanent maglev. Furthermore, in 1939, Braunbeck deduced that it is only possible to stabilize a super conductive or an electric maglev. In 2000, however, the present authors discovered that stable levitation is achievable by a combination of permanent magnetic and nonmagnetic forces, and its stability can be maintained even with mere passive magnetic forces by use of the gyro-effect.

Design concepts: An improved design of permanent maglev impeller pump has been developed. Passive magnetic (PM) bearings support the rotor radially; on its right side, an impeller is fixed and on its left side a motor magnets-assemble is mounted. Unlike a previous prototype design, in which the rotor magnets were driven by a motor via magnetic coupling, a motor coil is installed opposite to the motor magnets disc, producing a rotating magnetic field. At standstill or if the rotating speed is lower than 4000 rpm, the rotor has one axial point contact with the motor coil. The contact point is located at the centre of the rotor. As the rotating speed increases gradually to higher than 4000 rpm, the rotor will be drawn off from the contact point by the hydrodynamic force of the fluid. Then the rotor becomes fully suspended.

Key points of stabilization: For radial and peripheral stabilization, a gyro-effect is important, which is realized by designing the motor magnets disc to have large diameter, short length and high rotating speed; for axial stability, an axial rehabilitating force is necessary, which is produced by PM bearings.

Results: The rotor demonstrated a full levitation by rotation over 4000 rpm. As a left ventricular assist device, the rotation of the pump has a speed range from 5000 to 8000 rpm. The relation between pressure head and flow rate indicates that there is neither mechanical friction nor hydrodynamic turbulence inside the pump; the former is due to the frictionless maglev and the latter is a result of the streamlined design of the impeller.  相似文献   

3.
BACKGROUND: In 1839, Earnshaw proved theoretically that it is impossible to achieve a stable equilibrium with a pure permanent maglev. Furthermore, in 1939, Braunbeck deduced that it is only possible to stabilize a super conductive or an electric maglev. In 2000, however, the present authors discovered that stable levitation is achievable by a combination of permanent magnetic and nonmagnetic forces, and its stability can be maintained even with mere passive magnetic forces by use of the gyro-effect. DESIGN CONCEPTS: An improved design of permanent maglev impeller pump has been developed. Passive magnetic (PM) bearings support the rotor radially; on its right side, an impeller is fixed and on its left side a motor magnets-assemble is mounted. Unlike a previous prototype design, in which the rotor magnets were driven by a motor via magnetic coupling, a motor coil is installed opposite to the motor magnets disc, producing a rotating magnetic field. At standstill or if the rotating speed is lower than 4000 rpm, the rotor has one axial point contact with the motor coil. The contact point is located at the centre of the rotor. As the rotating speed increases gradually to higher than 4000 rpm, the rotor will be drawn off from the contact point by the hydrodynamic force of the fluid. Then the rotor becomes fully suspended. KEY POINTS OF STABILIZATION: For radial and peripheral stabilization, a gyro-effect is important, which is realized by designing the motor magnets disc to have large diameter, short length and high rotating speed; for axial stability, an axial rehabilitating force is necessary, which is produced by PM bearings. RESULTS: The rotor demonstrated a full levitation by rotation over 4000 rpm. As a left ventricular assist device, the rotation of the pump has a speed range from 5000 to 8000 rpm. The relation between pressure head and flow rate indicates that there is neither mechanical friction nor hydrodynamic turbulence inside the pump; the former is due to the frictionless maglev and the latter is a result of the streamlined design of the impeller.  相似文献   

4.
The effects of impeller geometry on the performance of a centrifugal blood pump model [the MSCBP design of Akamatsu and Tsukiya (The Seventh Asian Congress of Fluid Mechanics (1997), 7-10) at a 1:1 scale] have been investigated both experimentally and computationally. Four impeller designs were tested for pump hydraulic performance at the operating point (i.e. 2000 rpm), using blood analog as the working fluid. Each impeller has seven blades with different configurations including the radial straight blade and backward swept blade designs. The results show that both designs can achieve a stable head of about 100 mm Hg at the operating point. Subsequent investigations involved the visualization of the relative flow field within the impeller passages via the image de-rotation system coupled with a 2.5 W argon ion laser. Flow structures in all sectors of each impeller were examined and discussed. To further quantify the possible effects of blade geometry to thrombus formation and hemolysis, computational fluid dynamics (CFD) was used to simulate a simplified two-dimensional blade-to-blade flow analysis so as to estimate the shear stress levels. The results indicate that the stress levels found within the blade passages are generally below the threshold level of 150 N/m(2) for extensive erythrocyte damage to occur. There are some localized regions near the leading edge of the blades where the stress levels are 60% above the threshold level. However, given such a short residence time for the fluid particles to go through these high shear stress regions, their effects appear to be insignificant.  相似文献   

5.
The helical flow pump (HFP) was invented to develop a total artificial heart at the University of Tokyo in 2005. The HFP consists of the multi-vane impeller involving rotor magnets, a motor stator and pump housing having double-helical volutes. To investigate the characteristics of the HFP, computational fluid dynamics analysis was performed. Validation of the computational model was performed with the data of the actual pump. A control computational model in which the vane area corresponded approximately to that of the actual pump was designed for the parametric study. The parametric study was performed varying the vane height, vane width and helical volute pitch. When the vane height was varied from 0.5 to 1.5 times that of the control computational model, the H–Q (pressure head vs. flow) and efficiency curves were translated in parallel with the vane height. When the vane height was two and three times that of the control computational model, the profile of these curves changed. From the results, the best proportion for the vane was considered to be a vane height between 1.5 and 2 times the vane width. The effect of vane width was not very strong compared to that of the vane height. A similar tendency in vane height was observed by varying the helical volute pitch. The best helical volute-pitch size is considered to be between 1.5 and 2 times the vane width. Although further study is necessary to determine the best values for these parameters, the characteristics of the pump parameters in the HFP could be approximately clarified.  相似文献   

6.
Previously it has been found by pump haemolysis testing that the flow rate has a remarkable effect on index of haemolysis (IH), while pressure head does not affect IH. Recent investigation with particle image velocimetry (PIV) technology has demonstrated that IH is directly related to the flow pattern of stream field in impeller vane channels. PIV is a visible approach showing the real flow status in the pump. The different positions of a tracer particle in two PIV pictures taken at 20 μs intervals decide the velocity value and direction. The velocity vectors of many particles draw the flow pattern of the stream field. The same pictures are taken at 2, 4 and 6 l min?1 flow rates while the pressure head is kept unchanged at 100 mmHg; then the pictures are taken at 4 l min?1 flow with different pressure heads of 80, 100 and 120 mmHg. Results reveal that the flow rate of 4 l min?1 (IH = 0.030) has the best stream field, and neither turbulence nor separation can be seen. In other flow rates (IH: 0.048 – 0.082), there is obviously second flow. Meanwhile, no significant difference can be seen among the PIV pictures of different pressure heads pumped, which agrees with the results of haemolysis testing showing that pressure has no effect on pump haemolysis. It may be concluded that the haemolysis property of a centrifugal pump can be assessed approximately by PIV pictures, which are much easier to take than haemolysis tests.  相似文献   

7.
Previously it has been found by pump haemolysis testing that the flow rate has a remarkable effect on index of haemolysis (IH), while pressure head does not affect IH. Recent investigation with particle image velocimetry (PIV) technology has demonstrated that IH is directly related to the flow pattern of stream field in impeller vane channels. PIV is a visible approach showing the real flow status in the pump. The different positions of a tracer particle in two PIV pictures taken at 20 micros intervals decide the velocity value and direction. The velocity vectors of many particles draw the flow pattern of the stream field. The same pictures are taken at 2, 4 and 6 l min(-1) flow rates while the pressure head is kept unchanged at 100 mmHg; then the pictures are taken at 4 l min(-1) flow with different pressure heads of 80, 100 and 120 mmHg. Results reveal that the flow rate of 4 l min(-1) (IH = 0.030) has the best stream field, and neither turbulence nor separation can be seen. In other flow rates (IH: 0.048 - 0.082), there is obviously second flow. Meanwhile, no significant difference can be seen among the PIV pictures of different pressure heads pumped, which agrees with the results of haemolysis testing showing that pressure has no effect on pump haemolysis. It may be concluded that the haemolysis property of a centrifugal pump can be assessed approximately by PIV pictures, which are much easier to take than haemolysis tests.  相似文献   

8.
The flow in the impeller of a centrifugal blood pump developed at the National Cardiovascular Center of Japan was clearly visualized by the oil film method to illustrate the overall flow structure inside the open-type impeller. The results showed that the main stream went along the pressure surface with a backward flow at the inlet. Large-scale vortices were formed near both tips of the suction side, and a low-velocity area was found in the middle of the suction side that could be eliminated by increasing the flow rate. These findings were helpful for improving the design of the impeller to enhance the hydraulic performance and the antithrombogenicity of the pump. Received: March 23, 2001 / Accepted: July 11, 2001  相似文献   

9.
Rotary blood pumps as a left ventricular assist device have several advantages over the use of existing pulsatile devices used for this purpose. The relative velocity distribution to the rotating impeller was observed by high-speed videography and particle image velocimetry (PIV) with the purpose of characterizing the unsteady fluid motion in the impeller and assessing antithrombogenicity based on the fluid dynamic properties within the flow path. Flow visualization in the present study has clearly shown the existence of drastic transient motion of flows in the impeller. The secondary flows developed in the passage, which are adverse in terms of hydrodynamic efficiency, contributed to the washout conditions on the blood contacting surface.  相似文献   

10.
To reduce the possible thrombogenicity of the pump studied, pump characteristics and washout conditions were compared between a pump with a semi-open and a pump with a full-open impeller. A difference in hydrodynamic performance was observed between the semi-open impeller and the full-open impeller; the pressure in the former was less by approximately 10%, and the maximum attainable efficiency decreased from 0.41 to 0.34. The flow pattern, as visualized by the oil film method, showed that the washout condition was enhanced by addition of the shroud, especially at the bottom region of the pump where the blood flow tended to be stagnant. The stagnant area was observed in the suction side of the impeller in both models, where the vortices shed from the impeller tip contributed to the washout. It was also shown that the flow entering the bottom region was circumferentially uniform in the full-open impeller, whereas in the semi-open impeller the flow was not uniform and entered primarily from the vicinity of the outlet port. The semi-open impeller, thus, was demonstrated to have better washout conditions than the full-open impeller regardless of a slight decrease in hydrodynamic efficiency.  相似文献   

11.
To finalize the design of the next generation of the HeartQuest left ventricular assist device, a suitable impeller had to be designed and tested. The new prototype was based on calculations and test results of previous designs, but required several changes to decrease the size. For most pump designs, this is a simple matter of altering impeller geometry and rotational speed to achieve the desired pressure rise and flow rate. However, this particular pump was limited by housing geometry and the magnetic bearings that support the impeller. Without much freedom in the overall impeller size, the only parameters open to the designers were the blade profiles and the rotating speed. Rather than build several candidates and test them in a rig at enormous cost, computational models of several designs were tested and analyzed. This not only saved money, but also sped up the development time for the project. The computer models were developed in TASCflow, a computational fluid dynamics software package from AEA Technologies. This paper analyzes the data from several of the selected models, paying close attention to pumping performance and general trends from specific design changes.  相似文献   

12.
The Gyro centrifugal pump, developed as a totally implantable artificial heart, was designed with a free impeller in which the rotational shaft (male bearing) of the impeller was completely separated from the female bearing. For this type of pump, it is very important to keep the proper magnet balance (impeller-magnet and actuator-magnet balance) to prevent thrombus formation or bearing wear. When the magnet balance is not proper, the impeller is jerked down into the bottom bearing. On the other hand, if magnet balance is proper, the impeller is lifted off the bottom of the pump housing within a certain range of pumping conditions. In this study, this floating phenomenon was investigated in detail. The floating phenomenon was proven by observation of the impeller behavior by means of a transparent acrylic pump. The impeller floating phenomenon was mapped on a pump performance curve. The impeller floating phenomenon is affected by the magnet-magnet coupling distance and the rotational speed of the impeller. To keep the proper magnet balance and to maintain the impeller floating phenomenon at the driving conditions of right and left pumps, the magnet-magnet coupling distance was altered by a spacer that was installed between the pump and actuator. It became clear that the same pump could handle different conditions (right and left ventricular assist) by changing the thickness of the spacer. When magnet balance is proper, the floating impeller phenomenon occurs automatically in response to the impeller revolution. This is called "the dynamic revolutions per minute suspension."  相似文献   

13.
Intravascular application of microaxial blood pumps as heart assist devices requires a maximum in size reduction of the pump components. These limitations affect the design process in many ways and restrict the number of applicable experimental procedures, but a detailed knowledge of the hemodynamics of the pump is of great interest for efficiency enhancement and reduction of blood trauma and thrombus formation. Computational fluid dynamics (CFD) offers a convenient approach to this goal. In this study, the inlet, vane, and outlet regions of a microaxial blood pump used as an intraaortic left ventricular assist device are analyzed by CFD and 3-dimensional (3-D) particle tracking velocimetry (PTV). For this purpose, a mock loop is set up that facilitates 3-D flow visualization. Flow in the main part of this testing device is modeled and computed by means of CFD. Pump head/flow (HQ) characteristics, axial pressure distribution, and particle images are then compared with numerical flow data. Results show that the pump performance characteristics, as well as inlet and outlet swirl predicted by the CFD model, are quite accurate compared with measured data. Proper boundary condition definitions and spatial discretization topology requirements for satisfactory results are discussed.  相似文献   

14.
We investigated a miniature magnetically levitated centrifugal blood pump intended to deliver 0.3-1.5 l/min of support to neonates and infants. The back clearance gap between the housing and large volume of the rotor, where the suspension and motor bearings are located, forms a continuous leakage flow path. Within the gap, flow demonstrates a very complex three-dimensional structure: the fluid adjacent to the rotating disk tends to accelerate by centrifugal force to flow radially outwards toward the outlet of the impeller against an unfavorable pressure gradient, which in turn forces blood to return along the stationary housing surfaces. Consequently, one or multiple vortices may be generated in the gap to block blood flow and cause the formation of a retrograde and antegrade leakage flow phenomenon at the gap outlet using an optimization process including extensive computational fluid dynamics (CFD) analysis of impeller refinements, we found that secondary blades located along the back or extended to the side surfaces of the rotor have the capacity to reduce and eliminate the retrograde flow in the back clearance gap. Flow visualization confirmed the CFD-predicted flow patterns. This work demonstrates the utility of CFD-based design optimization to optimize the fluid path of a miniature centrifugal pump.  相似文献   

15.
目的 设计和研发满足心室辅助要求的植入式磁悬浮离心血泵.方法 应用计算机辅助设计(CAD)一种磁悬浮式的离心血泵,应用计算机流体力学方法对新型血泵的流场进行分析.结果 ①在血泵流道内血液流动无滞留区域.②叶轮底端血液由外向内进入中心悬浮装置下端,并经过中心悬浮装置与叶轮之间的空隙回流入叶轮中心.③叶轮上端血液回流入叶轮中心,并与流入道的血液汇合,重新流入凹槽内.结论 血液在血泵流道充分流动无滞留部位.叶轮上下端有部分血液回流可以使血泵工作效率降低,但回流的血液具有防止血栓形成、协助叶轮悬浮、防止局部过热的作用.血泵入口叶轮衔接部位及血泵出口衔接部位为潜在涡流区域.  相似文献   

16.
目的应用专业计算流体动力学(computational fluid dynamics,CFD)分析软件FLUENT,对一种具有长短叶片的Sarns离心式血泵的内部流场进行三维数值模拟。方法利用Solidworks软件对Sams型血泵进行三维建模,然后对所建模型网格处理,通过选取标准,κ-ε湍流模型和SIMPLE算法,具体分析了内部流动状态、压力分布、壁面剪切力等流场特性。结果结果表明,该离心泵内部流场分布较不匀,叶片及血泵出口处有回流和旋涡现象,剪切力大小基本处于致红细胞破碎的临界状态之下,高转速下剪切力最大,主要分布在叶轮区域,但暴露时间极短,基本满足血液生理要求。结论该研究为Sarns血泵的进一步优化提供了理论基础。  相似文献   

17.
Magnetic bearings have no mechanical contact between the rotor and stator, and a rotary pump with magnetic bearings therefore has no mechanical wear and thrombosis. The magnetic bearings available, however, contain electromagnets, are complicated to control and have high energy consumption. Therefore, it is difficult to apply an electromagnetic bearing to a rotary pump without disturbing its simplicity, reliability and ability to be implanted. The authors have developed a levitated impeller pump using only permanent magnets. The rotor is supported by permanent radial magnetic forces. The impeller is fixed on one side of the rotor; on the other side the rotor magnets are mounted. Opposite these rotor magents, a driving magnet is fastened to the motor axis. Thereafter, the motor drives the rotor via magnetic coupling. In laboratory tests with saline, where the rotor is still or rotates at under 4,000 rpm, the rotor magnets have one point in contact axially with a spacer between the rotor magnets and the driving magnets. The contacting point is located in the center of the rotor. As the rotating speed increases gradually to more than 4000 rpm, the rotor will disaffiliate from the stator axially, and become fully levitated. Since the axial levitation is produced by hydraulic force and the rotor magnets have a giro-effect, the rotor rotates very stably during levitation. As a left ventricular assist device, the pump works in a rotating speed range of 5,000-8,000 rpm, and the levitation of the impeller is assured by use of the pump. The permanent maglev impeller pump retains the advantages of the rotary pump but overcomes the disadvantages of the leviated pump with electromagnetic-bearing, and has met with most requirements of artificial heart blood pumps, thus promising to have more applications than previously.  相似文献   

18.
Magnetic bearings have no mechanical contact between the rotor and stator, and a rotary pump with magnetic bearings therefore has no mechanical wear and thrombosis. The magnetic bearings available, however, contain electromagnets, are complicated to control and have high energy consumption. Therefore, it is difficult to apply an electromagnetic bearing to a rotary pump without disturbing its simplicity, reliability and ability to be implanted. The authors have developed a levitated impeller pump using only permanent magnets. The rotor is supported by permanent radial magnetic forces. The impeller is fixed on one side of the rotor; on the other side the rotor magnets are mounted. Opposite these rotor magents, a driving magnet is fastened to the motor axis. Thereafter, the motor drives the rotor via magnetic coupling. In laboratory tests with saline, where the rotor is still or rotates at under 4000 rpm, the rotor magnets have one point in contact axially with a spacer between the rotor magnets and the driving magnets. The contacting point is located in the center of the rotor. As the rotating speed increases gradually to more than 4000 rpm, the rotor will disaffiliate from the stator axially, and become fully levitated. Since the axial levitation is produced by hydraulic force and the rotor magnets have a giro-effect, the rotor rotates very stably during levitation. As a left ventricular assist device, the pump works in a rotating speed range of 5000-8000 rpm, and the levitation of the impeller is assured by use of the pump. The permanent maglev impeller pump retains the advantages of the rotary pump but overcomes the disadvantages of the leviated pump with electromagnetic-bearing, and has met with most requirements of artificial heart blood pumps, thus promising to have more applications than previously.  相似文献   

19.
Inverse design and CFD investigation of blood pump impeller   总被引:3,自引:0,他引:3  
In this paper, a three-dimensional inverse design method using mean swirl specification is applied to the design of centrifugal blood pump impeller blades. CFD investigation of the passage flows is carried out to analyze the flow field and pressure generated across the blade. The results show that the possibility of blood cells' damage may not be increased when the pressure developed is increased. This technique can provide designers valuable insight on the development of efficient blood pump with reduced risk of blood traumatization.  相似文献   

20.
For long-term application, rotary pumps have to solve the problems of bearing wear and thrombosis along the bearing. Most investigators choose the magnetic bearing to realize zerofriction and no contact between the rotor and stator; the former avoids the mechanical wear and the latter eliminates the possibility of thrombus formation. The authors have tried and found, however, that it is difficult to apply a magnetic bearing to the rotary pump without disturbing its simplicity, reliability and implantability, and have therefore developed a much simpler and much more creative approach to achieve the same results. Instead of using a sliding bearing, a rolling bearing has been devised for the pump, and its friction is about 1/15 of the sliding bearing. Furthermore, a wear-proof material of ultra-high-molecular weight polythene has been adopted to make the rollers, and its anti-wear property is 8 times better than metal. Thereby, the service life of the bearing has been prolonged to ten years according to the documents provided by the producer. In order to prevent the thrombus formation along the bearing, the impeller reciprocates axially as the impeller changes its rotating speed periodically to produce a pulsatile flow. The reciprocation is the result of the effects of a magnetic force between the motor rotor and stator, and a hydraulic force between the blood flow and the impeller. Similar to a piston pump, the oscillating impeller can make the blood flow in and out of the bearing, resulting in wash-out once a circle. This obviously helps to prevent thrombosis along the bearing and in the pump. The endurance tests with saline of this novel pump demonstrated the durability of the device. It promises to be able to assist the circulation of patients permanently, and to be able to replace heart transplantation in the future.  相似文献   