首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Objectives. This study sought to assess the diagnostic efficacy of adenosine technetium-99m (Tc-99m) sestamibi myocardial perfusion single-photon emission computed tomography (SPECT) in a consecutive series of female patients.Background. The utility of adenosine myocardial perfusion SPECT for the detection of coronary artery disease is not well defined in women because most studies have described a predominantly male population with a high prevalence of coronary artery disease.Methods. Of the 201 consecutive female patients in the study group who had undergone adenosine Tc-99m sestamibi myocardial perfusion SPECT, 130 had coronary angiography within 2 months of the nuclear test, and the other 71 had a low likelihood (<10%, mean [±SD] 5 ± 3%) of coronary artery disease. The SPECT protocol used separate acquisition of rest thallium-201 and adenosine Tc-99m sestamibi and was visually analyzed in 20 segments with a semiquantitative five-point scoring system (0 = normal; 4 = absent uptake).Results. The normaley rate in patients with a low likelihood of coronary artery disease was 93% (66 of 71). Among the catheterized group, the overall sensitivity, specificity and predictive accuracy of adenosine sestamibi SPECT for detecting coronary artery disease (⪰50% diameter stenosis) were 93% (87 of 94), 78% (28 of 36) and 88% (115 of 130), respectively. In the 103 patients without a prior myocardial infarction, the sensitivity, specificity and predictive accuracy were 91% (61 of 67), 78% (28 of 36) and 86% (89 of 103), respectively, for detecting ⪰50% diameter stenosis. Of particular interest, the sensitivity and specificity were as high in patients with nonanginal symptoms (93% and 69%, respectively) as in patients with angina (92% and 83%, respectively, p = NS). The sensitivity and specificity among patients with a relatively low (<25%), intermediate (between 25% and 75%) or high prescan likelihood of coronary artery disease (>75%) were similar: 82% and 82%, 93% and 73%, and 95% and 100%, respectively. The sensitivity and specificity for detecting individual diseased vessels (⪰50% diameter stenosis) were, respectively, 76% and 81% for the left anterior descending coronary artery, 44% and 90% for the left circumflex coronary artery and 75% and 77% for the right coronary artery.Conclusions. Adenosine Tc-99m sestamibi SPECT is an efficient protocol with high sensitivity and specificity for the detection of coronary artery disease in women irrespective of presenting symptoms or pretest likelihood of coronary artery disease and a high normaley rate. These findings are of particular clinical relevance because chest pain, anginal or otherwise, has been shown to be a frequent but a less specific marker for coronary artery disease among female patients.  相似文献   

2.
Technetium-99m (Tc-99m) sestamibi is a new myocardial perfusion imaging agent that offers significant advantages over thallium-201 (Tl-201) for myocardial perfusion imaging. The results of the current clinical trials using acquisition and processing parameters similar to those for Tl-201 and a separate (2-day) injection protocol suggest that Tc-99m sestamibi and Tl-201 single photon emission computed tomography (SPECT) provide similar information with respect to detection of myocardial perfusion defects, assessment of the pattern of defect reversibility, overall detection of coronary artery disease (CAD) and detection of disease in individual coronary arteries. Tc-99m sestamibi SPECT appears to be superior to Tc-99m sestamibi planar imaging because the former provides a higher defect contrast and is more accurate for detection of disease in individual coronary arteries. Research is currently under way addressing optimization of acquisition and processing of Tc-99m sestamibi studies and development of quantitative algorithms for detection and localization of CAD and sizing of transmural and nontransmural myocardial perfusion defects. It is expected that with the implementation of the final results of these new developments, further significant improvement in image quality will be attained, which in turn will further increase the confidence in image interpretation. Development of algorithms for analysis of end-diastolic myocardial images may allow better evaluation of small and nontransmural myocardial defects. Furthermore, gated studies may provide valuable information with respect to regional myocardial wall motion and wall thickening. With the implementation of algorithms for attenuation and scatter correction, the overall specificity of Tc-99m sestamibi SPECT should improve significantly because of a substantial decrease in the occurrence of attenuation-related image artifacts.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

3.
4.
Background: The stress level achieved during exercise thallium-201 myocardial imaging may influence its sensitivity for detecting coronary artery disease (CAD). The effect of exercise adequacy on the accuracy of technetium-99m sestamibi (MIBI) imaging has not been studied. Hypothesis: The study was undertaken to assess the effect of exercise level achieved on sensitivity for detecting CAD. Methods: A consecutive series of 250 patients (mean age 60 ± 10 years) with CAD by angiography underwent symptom-limited exercise MIBI single-photon emission computed tomography. Single-vessel CAD was found in 66 patients, double-vessel CAD in 84, triple-vessel CAD in 80, and left main disease in 20. Results: No significant differences were found in sensitivities of an abnormal MIBI scan or a reversible defect among 102 patients reaching 85% of age-predicted heart rate and 148 who did not (82 vs. 89% and 66 vs. 70%, respectively, p = NS). Patients (n = 128) able to exercise ≤6 min had a higher incidence of abnormal scans and reversible defects than 122 patients with a greater exercise duration (91 vs. 82% and 75 vs. 61 %, respectively, both p<0.05). Sensitivity of an abnormal MIBI scan for multivessel disease was greater than for single-vessel disease in patients who achieved ≥85% of age predicted heart rate (91 vs. 59%, p<0.01) and in those who exercised >6 min (89 vs. 66%, p<0.01). No significant differences in the sensitivities of an abnormal MIBI study for multivessel versus single-vessel CAD were seen in patients achieving lower peak levels of exercise. Sensitivity of ischemic ST depression was lower than that of MIBI tomography at all levels of exercise. Conclusions: The sensitivity of exercise MIBI tomography for angiographic CAD is relatively independent of the peak heart rate achieved. Exercise duration of >6 min is associated with a significantly higher MIBI abnormality rate than a duration of >6 min, possibly reflecting the effect of myocardial ischemic burden on exercise ventricular function. Regardless of level of stress or its duration, exercise MIBI tomography improves the sensitivity for CAD detection compared with stress-induced ischemic ST depression.  相似文献   

5.
The incremental prognostic value of combined regional wall motion and perfusion over perfusion alone by gated single-photon emission computed tomographic myocardial perfusion scintigraphy has not been evaluated. Of the 402 consecutive patients who underwent stress single-photon emission computed tomographic myocardial perfusion scintigraphy for suspected myocardial ischemia, we identified 333 patients (217 men, mean age 63 +/- 10 years; exercise in 249 and dipyridamole adminstered to 84). Visual scoring of perfusion images and regional wall motion used 20 segments and a scale of 0 to 4. Resting and poststress left ventricular ejection fraction was automatically generated. On follow-up (median 13 months), 30 hard cardiac events (17 cardiac deaths, 13 nonfatal acute myocardial infarctions) and 66 total cardiac events (including hard events, 26 with unstable angina, and 10 who underwent late revascularization) occurred. After adjustment for prescan information, the best independent predictors of hard events were summed stress score for wall motion (Wald's chi-square 8.3, p <0.004) and several vascular territories with ischemia by perfusion/function (Wald's chi-square 6.2, p <0.01). The strongest predictors of all cardiac events were the number of ischemias (Wald's chi-square 32.1, p <0.0001) and the number of ischemic vascular territories by perfusion (Wald's chi-square 13.1, p <0.0001). Addition of function data to the combined model of perfusion data yielded an incremental value of 26% for predicting hard events but not for all events. In conclusion, the assessment of combined perfusion/function provides incremental prognostic information for further hard events with perfusion data alone; perfusion data best predict all cardiac events.  相似文献   

6.
7.
One a tribute of a Tc 99m labeled myocardial agent is the possibility to measure both ventricular function and myocardial perfusion with a single injection. To assess this, normal volunteers, 14 patients with coronary artery disease (CAD) and two suffering from cardiomyopathy with normal coronaries, were injected with 8-10 mci carbomethoxy-isopropyl-isonitrile or 20 mci Rp-30 Tc 99m at peak semi-recumbent bicycle exercise and again at rest. Thirty msec per frame first pass data, and 5 min static anterior, 40(0-) and 70(0-) left anterior oblique images were obtained. Standard Thallium 201 stress test were also done, within one month, and were at the same level of exercise. The left ventricular ejection fraction (EF) increased with exercise (69%-76%) in normal patients. All studies showed normal myocardial perfusion on exercise. In CAD patients the EF increased in some patients who had ischemia. Perfusion images with Tc 99m during exercise and at rest had an identical correlation with Thallium 201. The results support the concept of dual ventricular function and perfusion studies using a single Tc 99m labelled myocardial agent, and suggest that this could become the standard radionuclide stress tests in the future.  相似文献   

8.
First-pass radionuclide ventriculography followed by myocardial SPECT with technetium-99m methoxy isobutyl isonitrile (Tc-99m MIBI) was performed on 12 patients with suspected coronary artery disease at rest and during exercise. Left ventricular wall motion and myocardial perfusion were assessed simultaneously and compared on a segment-by-segment basis. Segmental agreement between Tc-99m MIBI and Tl-201 with regard to the presence of perfusion defects was 95% (57/60) at rest and 93% (37/40) during exercise. With respect to the assessment of myocardial ischemia and/or infarction, abnormalities in regional wall motion agreed with the presence of myocardial perfusion defects in 18 out of 21 segments (86%). Simultaneous evaluation of regional wall motion and myocardial perfusion by Tc-99m MIBI may provide useful information for the assessment of myocardial ischemia.  相似文献   

9.
Limited exercise combined with dipyridamole increases myocardial perfusion defect severity compared with dipyridamole alone. The impact of limited exercise combined with adenosine on myocardial perfusion defect severity is unknown. This study compares myocardial perfusion defect severity with adenosine alone and adenosine combined with limited exercise. Thirty-two patients with coronary artery disease underwent on separate days and in randomized order technetium-99m sestamibi (25 to 30 mCi) single-photon emission computed tomographic imaging at rest, after adenosine (140 microg/kg/min x 6 minutes), and after adenosine (140 microg/kg/min x 4 minutes) during 6 minutes of modified Bruce treadmill exercise (adenosine-exercise). Radiopharmaceutical was injected at 3 and 5 minutes during adenosine and adenosine-exercise, respectively. Images were interpreted by a consensus agreement of 3 nuclear cardiologists without knowledge of patient identity, stress protocol, or clinical data using a 17-segment model and 5-point scoring system. A summed stress score (SSS), summed rest score (SRS), and summed difference (SSS-SRS) score (SDS) were calculated for each image. Peak stress heart rate and rate-pressure product were higher for adenosine-exercise than adenosine (102 +/- 19 vs 81 +/- 11 beats/min and 13,972 +/- 4,265 vs 10,623 +/- 2,131, respectively; both p <0.001). Sensitivity for detection of > or = 50% coronary stenosis was 75% and 72% for adenosine-exercise and adenosine, respectively (p = NS). There were no differences in SSS and SDS between adenosine-exercise and adenosine (8.2 +/- 5.9 vs 8.1 +/- 6.3 and 4.9 +/- 4.1 vs 5.2 +/- 4.6, respectively; both p = NS). Thus, in patients with coronary artery disease, limited treadmill exercise combined with adenosine does not increase myocardial perfusion defect severity compared with standard adenosine technetium-99m sestamibi single-photon emission computed tomographic myocardial perfusion imaging.  相似文献   

10.
The state of left ventricular function and myocardial perfusionare important determinants of prognosis in patients with coronaryartery disease and information on both can be valuable for planningindividual patient management. We have studied the feasibilityof simultaneous measurement of left ventricular ejection fractionwith ultra short-lived gold-195 m (half life 30.5 seconds) andmyocardial perfusion with thallium-201, at rest and after exercisewith a single-crystal gamma camera. The results with first-passradionuclide angiocardiography (RNA) using gold-195 m at restwere reproducible and agreed closely with the results obtainedusing technetium-99 m equilibrium radionuclide angiocardiography(r = 0.93). Ejection fraction by firstpass gold-195 m RNA duringsemi-supine ergometric exercise decreased by >5% in 13 outof 18patients with coronary artery disease and stable angina.Simultaneous myocardial imaging with thallium-201 was abnormalin all patients. The change in regional wall motion abnormalityscore during exercise correlated with the change in myocardialperfusion (r = 0.71, P<0.01) and with the change in globalleft ventricular ejection fraction (r = 0.77, P<0.001). Thewidely differing energy levels and half-lives of gold-195 mand thallium-201 made it possible to separate clearly the imagesdue to each radionuclide. This study has demonstrated the feasibilityof simultaneous or sequential assessment of left ventricularfunction and myocardial perfusion during a single exercise test,a technique which can offer advantages in clinical evaluationof patients with coronary artery disease.  相似文献   

11.
The value of the new radionuclide tracer, technetium-99m (Tc-99m) sestamibi, to demonstrate myocardial perfusion in areas supplied by specific coronary arteries was evaluated in patients injected with the agent during cardiac catheterization. Tc-99m sestamibi differs from thallium-201 in its physical characteristics (photon energy 140 keV), half-life (6 hours) and lack of significant redistribution, allowing its administration during an episode of chest pain or ischemia occurring outside the nuclear medicine laboratory with later imaging to visualize the distribution. In 13 patients Tc-99m sestamibi was administered intravenously during balloon-occlusion angioplasty. In 11 of 13 patients, defects of the single photon emission computed tomography images corresponded to the area made ischemic during angioplasty. In the remaining 2 patients, abundant collateral flow was present and no defects were seen. In a second study, 15 patients had Tc-99m sestamibi selectively injected into a coronary artery during angiography. Later imaging identified the area supplied by the artery injected. Tc-99m sestamibi imaging can detect perfusion defects associated with short episodes of ischemia, and the area supplied by the different coronary arteries.  相似文献   

12.
目的评价锝-氮-氮欧乙替(^99mTc-N—NOET)心肌灌注显像检测冠心病的价值。方法对42例临床疑诊冠心病患者,行^99mTc-N-NOET运动负荷和再分布心肌灌注显像,所有患者行冠状动脉造影检查。结果在42例患者中,26例冠状动脉造影显示有冠状动脉狭窄病变,其中单支病变10例,二支病变7例,三支病变9例.^99mTc-N-NOET心肌显像检出心肌缺血或心肌梗死21例,未检出异常5例;16例冠状动脉造影正常患者,^99mTc-N-NOET心肌显像正常14例,异常2例.^99mTc-N-NOET心肌灌注显像诊断冠心病的敏感性为81%、特异性为88%、阳性预测值91%,阴性预测值74%,预测准确性为83%。诊断单支、二支和三支冠状动脉病变的敏感性分别为60%(6/10)、86%(6/7)、100%(9/9)。42例均无干扰心肌分辨的肺、肝重度摄取增高者。15min运动负荷显像肺脏摄取高,尤以冠状动脉狭窄患者增高明显。结论 ^99mTc-N-NOET心肌灌注显像检测冠心病敏感性、特异性较高,早期显像肺摄取增加与有意义的冠状动脉病变有关。  相似文献   

13.
14.
Fixed perfusion abnormalities in patients with known coronary artery disease (CAD) are associated with myocardial damage and adverse outcomes. However, the significance of these abnormalities in patients without known CAD is unclear. The aim of this study was to assess the prognostic significance of fixed versus reversible perfusion abnormalities in patients without known CAD. We studied 327 patients (58 +/- 11 years of age; 215 men) with no history of myocardial infarction or revascularization, who demonstrated myocardial perfusion abnormalities on stress (exercise or dobutamine) sestamibi tomographic imaging. Follow-up end points were all-cause mortality and hard cardiac events (cardiac death and nonfatal myocardial infarction). Myocardial perfusion abnormalities were reversible in 226 patients (69%) and fixed in 101 patients (31%). During a mean follow-up of 7 years, 72 patients (22%) died (cardiac death in 30) and 15 patients had nonfatal myocardial infarctions. The annual mortality rate was higher in patients with fixed abnormalities than in those with reversible abnormalities (4.4% vs 2.7%, p <0.01), whereas the annual hard cardiac event rate was not significantly different between the 2 groups (2.5% vs 2%). In a multivariate analysis model, the summed stress score was an independent predictor of hard cardiac events (risk ratio 1.7, 95% confidence interval 1.3 to 5.4). The presence of a fixed perfusion abnormality was independently associated with an increased risk of death after adjustment for clinical and stress test data and the summed stress score (risk ratio 2.5, 95% confidence interval 1.3 to 3.7). In patients with suspected, but no history of CAD, fixed perfusion abnormalities were associated with a higher risk of death compared with reversible perfusion abnormalities.  相似文献   

15.
BACKGROUND: An increased lung to heart ratio (LHR) on thallium-201 (Tl-201) stress myocardial perfusion imaging (MPI) is a predictor of adverse cardiac events and identifies people with extensive coronary artery disease (CAD). The implications of increased LHR in patients undergoing stress technetium-99m (tc-99m) sestamibi are developing. Our aim is to evaluate the relationship between increased LHR and extent of CAD in patients undergoing tc-99m sestamibi MPI. METHODS: We reviewed the records and images of 530 consecutive subjects who underwent exercise or adenosine tc-99 m sestamibi MPI. One hundred thirty-two had transient or partially reversible myocardial perfusion defects and 79 (exercise=34, adenosine=45, male=43, female=36, mean age=61 years) of these underwent coronary angiography (study population). The average LHR of these 79 subjects was compared to 79 patients (control population) with normal scans (exercise=50, adenosine=29, male=34, female=45, mean age=60 years). RESULTS: The mean LHR (+/-SE) in subjects with normal scans was 0.30+/-0.01. The mean LHR for those with abnormal scans and single vessel CAD who underwent exercise was 0.32+/-0.01 and pharmacological stress was 0.31+/-0.01. There was no statistically significant difference between the LHR of those with a normal scan and those with single vessel disease and an abnormal scan. However, there was a statistically significant association between the elevated LHR and multi-vessel CAD. The mean LHR for subjects with multi-vessel CAD with exercise was 0.39+/-0.01 (p=0.000) and for adenosine was 0.39+/-0.02 (p=0.000). CONCLUSION: An elevated LHR in patients undergoing exercise or pharmacological tc-99m MPI correlates with multi-vessel CAD.  相似文献   

16.
Coronary artery disease (CAD) is the leading cause of morbidity and mortality in diabetics. Early diagnosis of CAD and identification of high-risk subgroups, followed by appropriate therapy, may therefore enhance survival. This study sought to determine the value of stress myocardial perfusion single-photon emission computed tomography (SPECT) with technetium-99m sestamibi to detect perfusion defects and predict cardiac events in asymptomatic diabetics. One hundred eighty asymptomatic diabetics without known CAD who underwent 2-day stress technetium-99m sestamibi SPECT were followed up for 36 +/- 18 months. End points were defined as hard (myocardial infarction or cardiac death) or total events (myocardial infarction, cardiac death, or late revascularization). Logistic regression analysis evaluated clinical variables, type of stress, exercise treadmill test (ETT), and SPECT as predictors of end points. Perfusion defects were found in 26% of patients (15% reversible, 6% mixed, and 5% fixed). Clinical or ETT variables were not associated with perfusion defect type or with hard events. However, male gender predicted total events (chi-square 3.3; p = 0.01). An abnormal SPECT significantly increased the risk of hard events (chi-square 5.4; p = 0.001) and total events (chi-square 7.4; p = 0.0001). Extensive defects determined the highest risk of total events (chi-square 18.8; p = 0.0001). Event rates increased according to SPECT: 2% of hard events per year and 5% of total events per year in patients with normal SPECT versus 9% per year and 38% per year, respectively, in those with abnormal SPECT. Importantly, a normal SPECT identified a relatively low-risk subgroup of patients. Thus, stress technetium-99m sestamibi SPECT was useful in evaluating asymptomatic diabetics for the presence of CAD, and effectively risk-stratified this population.  相似文献   

17.
This study compared the results of stress and rest single-photon emission computed tomography imaging of myocardial perfusion using technetium-99m isonitrile (RP-30A) with the results of stress and redistribution tomographic thallium imaging and the results of coronary arteriography in 39 patients, 11 without and 28 with coronary artery disease (CAD). Each patient underwent 2 exercise studies at identical workload, heart rate and double product. In a subset of 13 patients, concomitant evaluation of left ventricular (LV) function using first-pass radionuclide angiography with a multi-crystal camera also was performed with bolus injections of isonitrile. Isonitrile had similar sensitivity (82 vs 82%, difference not significant), a slightly--but not significantly--higher specificity (100 vs 82%) and similar predictive accuracy (87 vs 82%) to thallium-201. The tracer uptake was assessed in 20 segments/study. There was concordance between the isonitrile and thallium-201 images in 723 of the 780 segments (93%) (kappa = 0.83 +/- 0.02). In general, the isonitrile images were considered of better quality than the thallium-201 images. All 10 patients with CAD who underwent concomitant first-pass radionuclide angiography had either perfusion abnormalities or an abnormal ejection fraction response to exercise. Thus, technetium-99m isonitrile provides a reliable method of assessment of CAD with a sensitivity, specificity and predictive accuracy comparable to that of exercise thallium-201 imaging. Additional advantages include better image quality and the ability to obtain concomitant assessment of LV function with the use of first-pass radionuclide angiography.  相似文献   

18.
Technetium-99m (Tc-99m) sestamibi has been used to evaluate the efficacy of thrombolytic therapy. Improved image quality due to the higher photon energy of Tc-99m and the increased allowable doses of this radiopharmaceutical along with its lack of redistribution makes Tc-99m sestamibi an acceptable imaging agent for such studies. This imaging agent was used for serial quantitative planar and tomographic imaging to assess the initial risk area of infarction, its change over time and the relation to infarct-related artery patency in patients with a first acute myocardial infarction. Twenty-three of 30 patients were treated with recombinant tissue-type plasminogen activator (rt-PA) within 4 hours after onset of acute chest pain. Seven patients were treated in the conventional manner and did not receive thrombolytic therapy. The initial area at risk varied greatly both in patients treated with rt-PA and in those who received conventional therapy. Patients with successful thrombolysis and patent infarct arteries had a significantly greater reduction of Tc-99m sestamibi defect size than patients who had persistent coronary occlusion. Serial imaging with Tc-99m sestamibi could find important application in future clinical research evaluating the efficacy of new thrombolytic agents. Direct measurements of the amount of hypoperfused myocardium before and after thrombolysis could provide rapid and unequivocal results using fewer patients and avoiding the use of “mortality” as an end point. This approach has not yet been widely tested in the clinical arena.  相似文献   

19.
Fundamental quantitative planar imaging techniques, evolved over the years, have been adapted to maximize the efficiency and clinical effectiveness of technetium-99m (Tc-99m) sestamibi imaging. To ensure reproducible image interpretation, the Society for Motion Picture and Television Engineers test pattern is used to obtain the necessary standardization of video and hard copy images. A standardized intensity scale intuitively relates count density to perceived brightness. Data are accumulated via standard 16-frame multiple gated acquisition and can be viewed in cine mode to assess wall motion. The images are then automatically summed for quantitative analysis of myocardial perfusion. Excessive extracardiac Tc-99m activity is automatically suppressed by the computer program to prevent suboptimal display of the heart. Due to the difference in heart background ratio and shape of the extracardiac background between resting and exercise Tc-99m sestamibi images, a modified interpolative background subtraction algorithm was developed. Image registration is necessary for accurate comparison of the rest and exercise images to detect redistribution. This is automatically accomplished by adjusting the position of the background-subtracted and centered images so as to maximize the cross-correlation coefficient. Profiles are generated to sample the myocardial count distribution and can be compared to a normal database, subject to confirmation by a competent interpreter. Rest redistribution is defined by a change in the myocardial distribution of Tc-99m sestamibi between exercise and rest images. Flashback display is used to identify subtle regions of redistribution that often signify residual viability within an infarct zone.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

20.
Technical aspects of myocardial SPECT imaging with technetium-99m sestamibi   总被引:7,自引:0,他引:7  
Most reports to date using single photon emission computed tomography (SPECT) with technetium-99m (Tc-99m) sestamibi have used acquisition parameters that were optimized for thallium-201. To fully utilize the superior imaging characteristics of Tc-99m sestamibi, there is a need to optimize the technical aspects of SPECT imaging for this agent. Performance can be enhanced through the careful selection of optimal radiopharmaceutical doses, imaging sequences, acquisition parameters, reconstruction filters, perfusion quantification methods and multidimensional methods for visualizing perfusion distribution. The current report describes theoretical considerations, phantom studies and preliminary patient results that have led to optimized protocols, developed at Emory University and Cedars-Sinai Medical Center, for same-day rest-stress studies, given existing instrumentation and recommended dose limits. The optimizations were designed to fit a low-dose-high-dose rest-stress same-day imaging protocol. A principal change in the acquisition parameters compared with previous Tc-99m sestamibi protocols is the use of a high-resolution collimator. The approach is being developed in both prone and supine positions. A new method for extracting a 3-dimensional myocardial count distribution has been developed that uses spherical coordinates to sample the apical region and cylindrical coordinates to sample the rest of the myocardium. New methods for visualizing the myocardial distribution in multiple dimensions are also described, with improved 2-dimensional, as well as 3- and 4-dimensional (3 dimensions plus time) displays. In the improved 2-dimensional display, distance-weighted and volume-weighted polar maps are used that appear to significantly improve the representation of defect location and defect extent, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号