首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A simplified arteriovenous malformation model in sheep: feasibility study.   总被引:3,自引:0,他引:3  
BACKGROUND AND PURPOSE: Recently, a swine model of a cerebral arteriovenous malformation (AVM) has been developed that closely resembles a human AVM of the brain. The creation of such a model requires sophisticated neurointerventional techniques. The purpose of this study was to develop a simple and cost-effective AVM animal model that does not require additional endovascular techniques. METHODS: A surgical anastomosis was created in seven sheep between the common carotid artery and the ipsilateral jugular vein, followed by ligation of the jugular vein above the anastomosis and of the proximal common carotid artery below the anastomosis. The anastomosis was created on the left side in four animals and on the right side in three. Cerebral angiography from the contralateral carotid artery was performed before and immediately after surgery to delineate the relevant cerebral vascular anatomy and to determine the direction of blood flow. RESULTS: An angiographic appearance simulating an AVM was found in all the animals. The ramus anastomoticus and arteria anastomotica functioned as the feeding vessels to the rete mirabile, which represented the nidus in our model, and to the jugular vein, which represented the draining vein from the malformation. Extensive collateral flow through the rete mirabile into the distal segment of the external carotid artery above the ligature was observed angiographically, with retrograde flow through the surgical anastomosis into the jugular vein. CONCLUSION: A simple surgically created experimental model for cerebral AVMs was developed in sheep without the need for additional complex endovascular catheter manipulations of intracranial branches. Such an animal model can substantially reduce the cost of research and training in the neurointerventional or radiosurgical management of AVMs.  相似文献   

2.
BACKGROUND AND PURPOSE: The rete mirabile in swine has been proposed as an arteriovenous malformation (AVM) model for acute experimental studies through surgical creation of a large carotid-jugular fistula. This report describes two endovascular modifications to simplify the surgical creation and provides hemodynamic parameters for the AVM model. METHODS: An AVM model was created in 29 animals to study n-butyl 2-cyanoacrylate polymerization kinetics. The common carotid artery (CCA) was punctured and a guiding catheter was inserted tightly into the origin of the ascending pharyngeal artery (APA). The CCA was ligated proximal to the catheter to create a pressure drop across the rete, which represented the AVM nidus. The catheter hub was opened whenever needed and served as the venous drainage of the AVM nidus. The contralateral APA served as the arterial feeder. Instead of the surgical ligation of the CCA, a temporary balloon occlusion was performed in three animals. RESULTS: A mean pressure gradient of 14.9 +/- 10.5 mm Hg (range, 4-42 mm Hg) was measured across the rete. The mean flow rate was 30.4 +/- 14.2 mL/min (range, 3.5-46 mL/min), as measured at the venous drainage. CONCLUSION: The endovascular and combined surgical-endovascular rete AVM model in swine is easy to construct and is less time-consuming than are the currently used models for acute experimental studies. Hemodynamic parameters can be monitored during the entire experiment and correspond to values found in human cerebral AVMs.  相似文献   

3.
BACKGROUND AND PURPOSE: We investigated the use of 2-poly-hydroxyethyl-methacrylate (2-P-HEMA) as an embolic agent in swine arteriovenous malformations (AVMs). METHODS: In seven mini swine, experimental AVMs were created surgically. The aim of treatment was complete embolization of the nidus compartment filled by the feeding artery, without brain embolization. Six animals received pure liquid 2-P-HEMA, and one, 50% 2-P-HEMA. For radiopacity, liquid 2-P-HEMA was mixed with tungsten powder. Six animals underwent angiographic follow-up within 5-8 mo (mean, 6.5 mo). Evaluation criteria were controllability, procedural reproducibility, and duration of the nidus occlusion. To detect complications, brain MR imaging and CT were performed. Histopathologic studies were performed to prove occlusion and assess histopathologic responses. RESULTS: 2-P-HEMA was easily injected through microcatheters, with a reproducible technique. Because of the radiopacity of the mixture, deep nidus penetration was controlled with fluoroscopy and confirmed with CT and histopathologic examination. In five AVMs embolized with pure 2-P-HEMA, feeder obliteration was long term. One animal had vasospasm during embolization, and complete obliteration of the main feeder was maintained for 3 mo, but partial recanalization developed 2 mo later. One animal receiving pure 2-P-HEMA had an infarction. In the animal embolized with 50% 2-P-HEMA, angiography and CT revealed embolic material in the circle of Willis; the animal died after embolization. No marked inflammatory reaction in the vessel wall or perivascular tissue was observed in the embolized AVMs. CONCLUSION: Experimental AVM embolization with pure 2-P-HEMA, made radiopaque with tungsten, is technically feasible in swine. Because of its properties, 2-P-HEMA has great potential as a therapeutic embolic agent.  相似文献   

4.
PURPOSETo evaluate the safety of silk as an embolic agent for preoperative embolization of cerebral arteriovenous malformations (AVMs) by assessing the histopathologic changes and hemorrhagic complications associated with its use.METHODSHistopathologic specimens, medical records, and radiologic records of 73 patients with AVMs embolized with silk (alone or in combination with other agents) were reviewed retrospectively. Forty-eight histologic specimens obtained at surgery were analyzed for inflammatory responses and compared with the time interval between embolization and surgery. Postembolization angiograms were assessed for vasculitis and CT scans were reviewed for evidence of hemorrhage after embolization.RESULTSThere was no angiographic evidence of vasculitis. Histologic evidence of vasculitis was absent or mild in 92% of cases and histologic evidence of perivascular inflammation was absent or mild in 73% of cases. The frequency of histologic changes associated with vasculitis, perivascular inflammation, and vessel necrosis varied with the time interval between embolization and AVM resection. Intracranial hemorrhage, as a direct complication of silk use, occurred in one patient. Another patient had subarachnoid hemorrhage 24 hours after embolization, caused by rupture of a posteroinferior cerebellar artery aneurysm. Intraventricular high-density material appeared on routine postembolization CT scans in two other patients who had intraventricular AVM extension. This high-density material was thought to be contrast extravasation from intrinsically leaky AVM nidus vessels and not frank hemorrhage.CONCLUSIONEmbolization of AVMs with silk does not result in marked inflammation or increased hemorrhagic complications as compared with other agents.  相似文献   

5.
BACKGROUND AND PURPOSE: Nidus rupture is a serious complication of intracranial arteriovenous malformation (AVM) embolotherapy, but its pathogenetic mechanisms are not well described. An AVM model based on electrical network analysis was used to investigate theoretically the potential role of hemodynamic perturbations for elevating the risk of nidus vessel rupture (Rrupt) after simulated AVM embolotherapy, and to assess the potential benefit of systemic hypotension for preventing rupture. METHODS: Five separate hypothetical mechanisms for nidus hemorrhage were studied: 1) intranidal rerouting of blood pressure; 2) extranidal rerouting of blood pressure; 3) occlusion of draining veins with glue; 4) delayed thrombosis of draining veins; and 5) excessively high injection pressures proximal to the nidus. Simulated occlusion of vessels or elevated injection pressures were implemented into the AVM model, and electrical circuit analysis revealed the consequent changes in intranidal flow, pressure, and Rrupt for the nidus vessels. An expression for Rrupt was derived based on the functional distribution of the critical radii of component vessels. If AVM rupture was observed (Rrupt > or = 100%) at systemic normotension (mean pressure [P] = 74 mm Hg), the theoretical embolization was repeated under systemic hypotension (minor P = 70 mm Hg, moderate P = 50 mm Hg, or profound P = 25 mm Hg) to assess the potential benefit of this maneuver in reducing hemorrhage rates. RESULTS: All five pathogenetic mechanisms under investigation were able to produce rupture of AVMs during or after embolotherapy. These different mechanisms had in common the capability of generating surges in intranidal hemodynamic parameters resulting in nidus vessel rupture. The theoretical induction of systemic hypotension during and after treatment was shown to be of significant benefit in attenuating these surges and reducing Rrupt to safer levels below 100%. CONCLUSION: The induction of systemic hypotension during and after AVM embolization would appear theoretically to be of potential use in preventing iatrogenic nidus hemorrhage. The described AVM model should serve as a useful research tool for further theoretical investigations of AVM embolotherapy and its hemodynamic sequelae.  相似文献   

6.
Assessment of intracranial arteriovenous malformations (AVMs) by conventional catheter angiography carries risks; moreover, this invasive procedure is often repeated for follow-up. We investigated the clinical applicability of two-dimensional thick-slice, contrast-enhanced magnetic resonance digital subtraction angiography (2D MRDSA) with high temporal resolution in the assessment of AVMs. We performed 78 2D MRDSA studies of treated or untreated small to medium-size AVMs on a 1.5 tesla imager. Two observers independently evaluated demonstration of nidus flow void on T2-weighted images and each component of the AVM on 2D MRDSA employing a three-point grading scale. In 55 patients with AVMs, the mean ratings of nidus flow voids, feeding vessels, nidi, draining vessels and early venous filling on MRI were 2.8, 2.4, 2.6, 2.8 and 2.8, respectively. sensitivity, specificity, positive and negative predictive values for an AVM using 2D MRDSA were 87, 100, 100 and 78%, respectively and for nidus flow voids on T2-weighted images 80, 91, 96 and 66%, respectively. 2D MRDSA can thus demonstrate haemodynamic features of AVMs. It can be employed as a less invasive, dynamic angiographic tool for follow-up of AVMs previously delineated by catheter angiography.  相似文献   

7.
BACKGROUND AND PURPOSE: Endovascular treatment with cyanoacrylate embolization is an option when complete obliteration of the nidus of an intracranial arteriovenous malformation (AVM) is the goal. Our purpose was to evaluate the rates of initial success and permanent cure of such treatment in a Chinese population. METHODS: Twenty-seven consecutive patients with an intracranial AVM underwent endovascular embolization with cyanoacrylate between June 1995 and May 1997. Twenty-six patients had cerebral AVMs and one had a cerebellar AVM. Curative embolization was attempted in 10 patients in whom 1) the nidus was not larger than 3 cm, 2) the number of feeders did not exceed three, and 3) the nidus was accessible with the tip of the catheter. We used a flow-directed microcatheter and a 20-25% mixture of cyanoacrylate in contrast medium. Long-term outcomes were observed angiographically and clinically. RESULTS: Complete embolization was achieved in six patients. No procedure-related complications occurred during attempted curative embolization. Follow-up angiography performed at 17-32 months showed complete obliteration of the AVM nidus in the six patients after initial embolization. These patients remained asymptomatic 5-7 years after treatment. The rate of permanent cure of the initially complete embolization was 100% (six of six). The success rate of endovascular cure for patients treated with curative intent was 60% (six of 10). The overall cure rate was 22% (six of 27). CONCLUSION: The overall initial cure rate of intracranial AVM with cyanoacrylate embolization was 22%. Initial angiographic evidence of complete embolization indicated permanent cure in these patients.  相似文献   

8.
The purpose of this study was to determine whether it is possible to predict the efficacy of therapeutic response to linac-based stereotactic radiosurgery for AVMs on the basis of the stagnation rate in the nidus, which was defined as follows: [(pooling time of contrast material in the nidus of AVM)/ (intracranial circulation time)] x 100. Cerebral angiograms of twenty-five AVMs were retrospectively evaluated, and the stagnation rates in the nidus were calculated before and one year after stereotactic radiosurgery. Reduction rate was also calculated by using angiography, and we statistically evaluated the relationship between the stagnation rates in the nidus and the reduction rates. The stagnation rates in the nidus prior to linac-based stereotactic radiosurgery were positively correlated with the reduction ratios of AVMs after stereotactic radiosurgery (r = 0.406, p = 0.0432). Our study suggested that a higher stagnation rate in the nidus of the AVM might be obliterated faster after linac-based stereotactic radiosurgery. Thus, calculation of the stagnation rate in the nidus before stereotactic radiosurgery is useful in predicting the efficacy of therapeutic response to linac-based stereotactic radiosurgery for AVMs.  相似文献   

9.
Seven patients with large arteriovenous malformations (AVMs) of the brain were selected for combined therapy with particulate embolization, followed by radiosurgery of the residual nidus. The goal of embolization was to reduce the patient nidus to a size that facilitated successful stereotactic radiosurgery. Angiograms obtained 1 and 2 years after radiosurgery were evaluated for changes in nidus size, flow rate, and feeding and draining vessels. One year after stereotactic radiosurgery, one AVM was angiographically undetectable. Three other AVMs demonstrated a volume reduction of greater than 50%, in addition to decreased shunt speed and altered angioarchitecture at 1-year follow-up. At 2-year follow-ups, two of seven AVMs were cured, and an additional two of seven had a greater than 98% reduction in nidus volume. Although one patient experienced a transient deficit from embolotherapy, none of our patients suffered a new neurologic deficit or a hemorrhage during the follow-up period. Our data support the efficacy of combined embolotherapy and radiosurgery for definitive therapy of selected large AVMs of the brain.  相似文献   

10.
Magnetic resonance (MR) angiography and spin-echo methods were used to evaluate intracerebral arteriovenous malformations (AVMs) in 10 patients. Spin-echo images obtained with flow presaturation demonstrated the nidus of the AVM in all cases, but it was difficult to determine feeding vessels. These vessels were directly visualized with three-dimensional MR angiography; their presence could be indirectly determined by means of selective presaturation of individual vessels, which resulted in a marked decrease in signal within the portion of the AVM supplied by that vessel. Vascular supplies from the internal carotid artery and anterior, middle, or posterior cerebral arteries were detected in all cases, but in three large malformations it was not possible to demonstrate small feeding vessels. MR angiograms were also helpful for further defining the nidus. The combination of MR angiographic and spin-echo methods provides information useful for therapeutic planning not provided by either technique alone.  相似文献   

11.
This study evaluated the long-term angiographic results in large cerebral arteriovenous malformations (AVMs) partially embolized with isobutyl-2-cyanoacrylate. Preembolization, immediate postembolization, and long-term follow-up angiograms were performed in 30 large, partially embolized brain AVMs. Particular attention was paid to the relative size of the residual AVM nidus and the embolized arterial feeders, to recruitment of new feeders, to the size of residual draining veins, and to the speed of arteriovenous shunt. Nine cases with less than 50% AVM nidus obliteration showed no significant morphologic changes. In 18 cases with 50-75% obliteration of the AVM nidus, 11 (61.1%) showed no significant changes, six (33.3%) showed enlargement of the AVM nidus, and one (5.5%) evolved to complete angiographic obliteration. In three cases with 75-99% AVM nidus obliteration, one remained unchanged, one showed an increase in the size of the AVM nidus, and one evolved to complete obliteration. Evaluation by plain film, CT, and cerebral angiography of the isobutyl-2-cyanoacrylate deposits showed that when the polymer was positioned predominantly in arterial feeders there was invariably reconstitution of the AVM nidus through leptomeningeal, deep medullary, and/or dural collaterals. This phenomenon did not occur when the isobutyl-2-cyanoacrylate was deposited mainly in the AVM nidus.  相似文献   

12.

Objective

A chronic arteriovenous malformation (AVM) model using the swine retia mirabilia (RMB) was developed and compared with the human extracranial AVM (EAVM) both in hemodynamics and pathology, to see if this brain AVM model can be used as an EAVM model.

Methods

We created an arteriovenous fistula between the common carotid artery and the external jugular vein in eight animals by using end-to-end anastomosis. All animals were sacrificed 1 month after surgery, and the bilateral retia were obtained at autopsy and performed hematoxylin and eosin staining and immunohistochemistry. Pre- and postsurgical hemodynamic evaluations also were conducted. Then, the blood flow and histological changes of the animal model were compared with human EAVM.

Results

The angiography after operation showed that the blood flow, like human EAVM, flowed from the feeding artery, via the nidus, drained to the draining vein. Microscopic examination showed dilated lumina and disrupted internal elastic lamina in both RMB of model and nidus of human EAVM, but the thickness of vessel wall had significant difference. Immunohistochemical reactivity for smooth muscle actin, angiopoietin 1, and angiopoietin 2 were similar in chronic model nidus microvessels and human EAVM, whereas vascular endothelial growth factor was significant difference between human EAVM and RMB of model.

Conclusions

The AVM model described here is similar to human EAVM in hemodynamics and immunohistochemical features, but there are still some differences in anatomy and pathogenetic mechanism. Further study is needed to evaluate the applicability and efficacy of this model.  相似文献   

13.
Arteriovenous malformations of the extremities: MR imaging   总被引:3,自引:0,他引:3  
Cohen  JM; Weinreb  JC; Redman  HC 《Radiology》1986,158(2):475-479
Eight patients with angiographically proved arteriovenous malformations (AVMs) of the extremities (seven congenital, one posttraumatic) were evaluated with magnetic resonance (MR) imaging using a 0.35-T superconducting system and spin-echo pulse sequences. Congenital AVMs appeared as accumulations of dilated tortuous blood vessels infiltrating the involved muscles. A posttraumatic acquired AVM of the shoulder consisted of a large feeding artery associated with a pseudoaneurysm and a soft-tissue mass. MR imaging allowed precise anatomic localization and provided details concerning the size and extent of the AVMs. The relationship of AVMs to specific muscle groups, bones, and vascular structures could be accurately determined. Although major feeding and draining vessels were identified, the exact arteries and veins supplying and draining the AVM could not be ascertained. Images obtained in the transverse plane consistently yielded the most useful information. MR imaging and angiography may be complementary techniques in the initial evaluation, follow-up, and treatment planning of AVMs of the extremities.  相似文献   

14.
Management of patients with brain arteriovenous malformations   总被引:22,自引:0,他引:22  
Arteriovenous malformations (AVMs) of the brain, which are probably genetically determined, are errors in the development of the vasculature that, together with the effects of blood flow, may lead to a focal arteriovenous shunt. Clinically, the adult patient may present with acute or chronic neurological symptoms-fixed or unstable-such as deficits, seizures or headache. Sometimes the lesion is an incidental finding. In about half of the patients, the revealing event is an intracranial haemorrhage. The prevalence of AVM in the western world is probably <0.01% and the detection rate is about one per 100,000 person-years. Most AVMs are revealed in patients 20-40 years of age. Therefore, the risk of developing neurological symptoms from an AVM, usually because of haemorrhage, increases with patient age. In the young adult population, AVMs are significant risk factors for hemorrhagic stroke. This risk increases with AVM volume and is higher in centrally located AVMs. Almost all patients with AVM are subjected to treatment, either by surgery, radiosurgery or embolisation, with the functional aim of reducing the risk of haemorrhage or to alleviate neurological symptoms with an acceptable treatment risk. Few neurocentres have physicians highly skilled in all treatment modalities. Therefore, the prescribed treatment may not be defined from an objective assessment of what is optimal for each individual patient, but rather from local expertise. In this context, more and better data about the natural history and the outcome of different treatments, as well as predictive models, would be valuable to help to optimise the management. Management strategies obviously differ according to local preferences, but results presented in the literature suggest the following strategy: (I) cortically located AVMs with a nidus volume <10 ml could be operated, with or without presurgical embolisation, unless there is a single feeder that can easily be catheterised and embolised for obliteration or other obvious target for embolisation, such as pseudoaneurysms or large fistulae; (II) centrally located AVMs with a nidus volume <10 ml should be treated by radiosurgery, unless suitable for embolisation as indicated above; (III) patients harbouring AVMs with a nidus volume >10 ml could benefit from targeted partial embolisation followed by radiosurgery or surgery, depending on the angioarchitecture; and (IV) AVMs >20 ml nidus volume usually have a high treatment risk with any treatment modality and are not obvious targets for treatment at all.  相似文献   

15.
Management of arteriovenous malformations (AVMs) is challenging, and there is no consensus regarding either the ideal approach or the treatment timing. Percutaneous embolization is the most frequent approach currently used and is considered the first-line technique for AVMs. There is an ongoing discussion about the best technical approach to embolize AVMs. AVMs associated with a dominant outflow vein (DOV) are rare. Embolization of both the DOV and the nidus is considered more effective. Herein, we report a novel technique of transvenous embolization of a DOV under negative pressure from an arterial balloon catheter in a case of a peripheral AVM. This technique allows the embolization of the DOV and the nidus retrogradely.  相似文献   

16.
Purpose To investigate the efficacy of oral administration of cilostazol to inhibit pseudointimal/intimal hyperplasia in swine TIPS models. Methods Successful TIPS creation was carried out in 11 of 12 healthy young pigs (20–25 kg). In the treatment group (n = 6), both cilostazol and aspirin were administered daily, from the first day of TIPS creation. The control group (n = 5) was administered only aspirin. The animals were followed-up for 2 weeks and then killed. The specimen (including portal vein, hepatic parenchymal tract, hepatic vein, and inferior vena cava) and stents were carefully bisected in a longitudinal fashion. The control group was compared with the treatment group by means of a gross and histologic evaluation of the degree of pseudointimal/intimal hyperplasia in the shunt. Results At the gross evaluation, the control group showed considerably more pseudointimal/intimal hyperplasia than the treatment group. Using microscopic evaluation, there was a statistically significant difference (p < 0.05) in the mean maximum pseudointimal/intimal hyperplasia thickness between the control group (2.97 ± 0.33 mm) and treatment group (0.73 ± 0.27 mm). Conclusion Oral administration of cilostazol may have been effective in reducing pseudointimal/intimal hyperplasia in swine TIPS models.  相似文献   

17.
Background: The characterization of brain arteriovenous malformation (AVM) angioarchitecture remains rewarding in planning and predicting therapy. The increased signal-to-noise ratio at higher field strength has been found advantageous in vascular brain pathologies.

Purpose: To evaluate whether 3.0T time-of-flight (TOF) magnetic resonance angiography (MRA) is superior to 1.5T TOF-MRA for the characterization of cerebral AVMs.

Material and Methods: Fifteen patients with AVM underwent TOF-MRA at 3.0T and 1.5T and catheter angiography (DSA), which was used as the gold standard. Blinded readers scored image quality on a four-point scale, nidus size, and number of feeding arteries and draining veins.

Results: Image quality of TOF-MRA at 3.0T was superior to 1.5T but still inferior to DSA. Evaluation of nidus size was equally good at 3.0T and 1.5T for all AVMs. In small AVMs, however, there was a tendency of size overestimation at 3.0T. MRA at 3.0T had increased detection rates for feeding arteries (+21%) and superficial (+13%) and deep draining veins (+33%) over 1.5T MRA.

Conclusion: 3.0T TOF-MRA offers superior characterization of AVM angioarchitecture compared with 1.5T TOF-MRA. The image quality of MRA at both 3.0 and 1.5T is still far from equal to DSA, which remains the gold standard for characterization of AVM.  相似文献   

18.
MR imaging in the management of supratentorial intracranial AVMs   总被引:2,自引:0,他引:2  
The MR images, CT scans, and angiograms of 15 consecutive patients with intracranial, supratentorial arteriovenous malformations (AVMs) were studied retrospectively. The three imaging techniques were evaluated separately to assess their utility in defining the size, characteristics, and location of the AVM nidus, its arterial supply, and venous drainage. The studies were also evaluated for their ability to show associated parenchymal abnormalities, the presence of mass effect, and changes occurring after embolization. MR was superior to both CT and angiography in showing the exact anatomic relationships of the nidus, feeding arteries, and draining veins, as well as in demonstrating the extent of AVM nidus obliteration after embolization. MR was more sensitive than CT in revealing associated parenchymal abnormalities and subacute hemorrhage. Because of flow-related artifacts and low sensitivity in distinguishing calcification from rapid flow and/or hemosiderin, MR seemed to have a low sensitivity for detecting old hemorrhage within an AVM nidus. Angiography is still needed in the planning of either surgical or endovascular treatment of AVMs.  相似文献   

19.
BACKGROUND AND PURPOSE:Embolization plays a key role in the treatment of arteriovenous malformations. The aim of this study was to evaluate an established (Onyx) and a novel (precipitating hydrophobic injectable liquid [PHIL]) liquid embolic agent in an in vitro AVM model.MATERIALS AND METHODS:An AVM model was integrated into a circuit system. The artificial nidus (subdivided into 28 honeycomb-like sections) was embolized with Onyx 18 (group Onyx; n = 8) or PHIL 25 (group PHIL; n = 8) with different pause times between the injections (30 and 60 seconds, n = 4 per study group) by using a 1.3F microcatheter. Procedure times, number of injections, embolization success (defined as the number of filled sections of the artificial nidus), volume of embolic agent, and frequency and extent of reflux and draining vein embolization were assessed.RESULTS:Embolization success was comparable between Onyx and PHIL. Shorter pause times resulted in a significantly higher embolization success for PHIL (median embolization score, 28 versus 18; P = .011). Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization (median volume per section of the artificial nidus, 15.5 versus 3.6 μL; P < .001).CONCLUSIONS:While the embolization success was comparable for Onyx and PHIL, pause time had a considerable effect on the embolization success in an in vitro AVM model. Compared with Onyx, lower volumes of PHIL were required for the same extent of embolization.

Arteriovenous malformations are complex vascular structures composed of feeding arteries, an intervening network of small pathologic blood vessels (the so-called nidus), and draining veins. The lack of an intervening capillary bed allows high-flow arteriovenous shunting of blood. While AVMs can occur throughout the entire body, cerebral AVMs are of particular relevance due to their ability to cause impairing neurologic symptoms and their considerable risk of hemorrhage.1Alone or in combination with microneurosurgery and stereotactic radiation therapy, embolization plays an important role in the management of cerebral AVMs.2 The aim of AVM embolization is complete filling of the nidus, while unwanted reflux into the feeding arteries should be minimized and premature embolization of the draining veins should be avoided.3A wide variety of embolic agents has been and is currently used for embolization of AVMs. At present, the liquid embolic agents (LEAs) ethylene-vinyl alcohol copolymer (EVOH) and n-butyl cyanoacrylate are used most frequently.4 Although the embolization results have improved since the introduction of EVOH-based LEAs with rates of complete obliteration ranging from 16% to 100%, the success rate of AVM embolization, especially for complex AVMs, is not yet satisfying.2,3 Currently, new LEAs are being introduced to improve embolization features, such as embolization efficacy, intraprocedural handling, and control. Furthermore, their use should improve fluoroscopic visibility and reduce artifacts in postinterventional imaging.The aim of this study was to evaluate an established EVOH-based embolic agent and a novel copolymer-based embolic agent in an in vitro AVM model.  相似文献   

20.
出血性脑动静脉畸形的影像特点与血管内治疗   总被引:7,自引:0,他引:7  
目的:探讨以出血发病的脑动静脉畸形的影像学特点与血管内治疗的技术操作。方法:经脑CT或MRI确认为脑实质内出血的56例病例,经DSA全脑血管造影证实为脑动静脉畸形(AVM),根据AVM病灶的特点,行经血管内超选择应用α-氰基丙烯酸正丁酯栓塞或结合放射外科治疗。结果:56例在1-3次栓塞后,36例病灶完全消除;1例因AVM中有新生的动脉瘤及1例术后1年发生出血而行第2次栓塞治愈,1例在接受X-刀治疗后3个月再次出血,经手术后痊愈。结论:AVM病灶内或病灶旁存在动脉瘤和动脉囊样扩张、引流静脉细小和脑室内生长的AVM是引起脑出血的主要原因,而在栓塞中优先处理动脉瘤样病变对防止脑出血有重要意义。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号