首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Purpose

To compare the reading times and detection performances of radiologists in concurrent-reader and second-reader modes of computer-aided detection (CAD) for lung nodules on multidetector computed tomography (CT).

Materials and Methods

Fifty clinical multidetector CT datasets containing nodules up to 20 mm in diameter were retrospectively collected. For the detection and rating of non-calcified nodules larger than 4 mm in diameter, 6 radiologists (3 experienced radiologists and 3 resident radiologists) independently interpreted these datasets twice, once with concurrent-reader CAD and once with second-reader CAD. The reference standard of nodules in the datasets was determined by the consensus of two experienced chest radiologists. The reading times and detection performances in the two modes of CAD were statistically compared, where jackknife free-response receiver operating characteristic (JAFROC) analysis was used for the comparison of detection performances.

Results

Two hundreds and seven nodules constituted the reference standard. Reading time was significantly shorter in the concurrent-reader mode than in the second-reader mode, with the mean reading time for the 6 radiologists being 132 s with concurrent-reader CAD and 210 s with second-reader CAD (p < 0.01). JAFROC analysis revealed no significant difference between the detection performances in the two modes, with the average figure-of-merit value for the 6 radiologists being 0.70 with concurrent-reader CAD and 0.72 with second-reader CAD (p = 0.35).

Conclusion

In CAD for lung nodules on multidetector CT, the concurrent-reader mode is more time-efficient than the second-reader mode, and there can be no significant difference between the two modes in terms of detection performance of radiologists.  相似文献   

2.

Purpose

To determine the frequency and significance of pulmonary nodules detected on thin-section CT in patients with extrapulmonary malignant neoplasms.

Materials and methods

The institutional review board approved this study. This study retrospectively evaluated 308 patients with extrapulmonary carcinomas or sarcomas and had undergone thin-section chest CT (2 mm slice thickness) for staging. Three radiologists identified non-calcified nodules and evaluated the size, the growth and the distance from the nearest pleural surface. The characteristics of the nodules were defined based on the results of either a diagnostic biopsy or nodule growth.

Results

One or more non-calcified pulmonary nodules were detected in 75% of the patients (233/308). One hundred and thirty-seven of these patients had nodules that met the criteria of either benign or malignant nodules. Nodules smaller than 10 mm were more likely to be benign, whereas those 10 mm or greater were more likely to be malignant (22/26, 85%; P < .0001). Most nodules less than 10 mm from the pleura were benign (91%), whereas approximately half of the nodules 10 mm or more away from the pleura were malignant (20/43, 47%; P < .0001). Patients with melanoma, sarcoma, or testicular carcinoma were more likely to have malignant nodules. A multivariable analysis demonstrated the nodule size (P < .0001) and distance from the pleura were predictive of malignancy.

Conclusion

The nodule detection rate on thin-section CT in patients with extrapulmonary malignancy is high. Most of the nodules smaller than 10 mm or less than 10 mm from the pleura are benign.  相似文献   

3.

Objective

To compare the detectability of simulated pulmonary nodules on chest radiographs between an irradiation side sampling indirect flat-panel detector (ISS-FPD) and computed radiography (CR).

Materials and methods

This study was an observer performance study. Simulated pulmonary nodules of 8 mm in diameter were superimposed on an anthropomorphic chest phantom. Chest radiographs were acquired under 2 exposure levels (4 and 3.2 mAs) with the ISS-FPD and the CR. Six thoracic radiologists evaluated all 40 images (10 patterns × 2 different exposure doses × 2 different systems) for the presence or absence of a lesion over each of 12 defined areas on a 3-megapixel monochrome liquid-crystal display. Receiver operating characteristic (ROC) curves were obtained for observation in predefined 480 areas. A jackknife method was used for statistical analysis. Differences with a P value of <0.05 were considered significant.

Results

The analysis of the observer detection of simulated pulmonary nodules showed larger areas under the ROC curve (AUC) by the ISS-FPD than by the CR. There was a statistically significant difference between the two systems at 3.2 mAs (P = 0.0330).

Conclusion

The ISS-FPD was superior to the CR for the detection of simulated pulmonary nodules at 3.2 mAs.  相似文献   

4.

Objectives

To characterize early features of lung cancers detected with low-dose computed tomography (LDCT) screening.

Materials and methods

Two radiologists reviewed prior LDCTs in 20 incident cancers diagnosed at annual repeat screening rounds and 83 benign nodules observed in the ITALUNG trial.

Results

No abnormality was observed in 3 cancers. Focal abnormalities in prior LDCT were identified in 17(85%) cancers (14 adenocarcinomas; 14 stage I). Initial abnormalities were intra-pulmonary in 10, subpleural in 4 and perifissural in 3. Average mean diameter was 9 mm (range 4.5–18 mm). Nine exhibited solid, 4 part-solid and 4 non-solid density. The margins were smooth and regular in 5 cases, lobulated in 6, irregular with spiculations in 3 and blurred in 3. Ten (59%) initial focal abnormalities had a round or oval nodular shape, but 7(41%) had a non-nodular complex (n = 5) or “stripe-like” (n = 2) shape. Bronchus sign was observed in 3 cases and association with cystic airspace in 2 cases. Non-solid density, complex or “stripe-like” shape, bronchus sign and association with cystic airspace had a specificity higher than 90%, but positive predictive value of every feature of incident lung cancers was low (range 10.4–50%).

Conclusions

The vast majority of cancers diagnosed at annual repeat show corresponding focal lung abnormalities in prior LDCTs. Perifissural location and non-nodular shape do not exclude the possibility of early lung cancer. Since specificity of the early features of incident lung cancer is incomplete and their positive predictive value is low, all focal pulmonary abnormalities detected in screened subjects should be re-evaluated in subsequent LDCTs.  相似文献   

5.

Purpose

To assess the ability of low-dose CT to detect and characterize the most common CT patterns of pulmonary disease.

Methods and materials

Sixty patients with nodules, consolidations or interstitial disease were scanned using a low-dose (128 mm × 0.6 mm, 40 reference mAs, 120 kVp) and standard-dose CT protocol (150 reference mAs, 120 kVp). Two radiologists with 3 and 10 years of thoracic imaging experience searched both exams in consensus for the most commonly observed CT patterns according to the Fleischner Society criteria, which consisted of 46 different subgroups of ground-glass opacities, nodules, interstitial and airspace diseases. The standard of reference was established by consensus of a panel of two experienced chest radiologists (9 and 12 years of experience).

Results

The lung segments (1080) showed 813 nodules, 596 ground-glass opacities, 74 airspace and 575 interstitial diseases and 64 normal segments. In particular, air-space disease and nodules were unaffected by the increase in noise. However, the sensitivity to detect ground-glass opacities, ground-glass nodules and interstitial opacities decreased significantly, from 89% to 77%, 86% to 68% and 91% to 71%, respectively (all p-values < 0.00001). Using iterative reconstruction instead of the applied filtered back projection sensitivity for ground-glass nodules rose to the sensitivity of standard-dose CT in an additional phantom study.

Conclusion

A low-dose CT of 40 mAs/120 kVp is feasible for detecting solid nodules, airspace, airways and pleural disease. For diagnosing pathologies consisting of ground-glass opacities or interstitial opacities, higher tube current or iterative reconstruction is required.  相似文献   

6.

Objective

To investigate the potential of MRI for lung nodule detection in a high-risk population in comparison to low-dose CT.

Methods

49 participants (31 men, 18 women, 51–71 years) of the German Lung Cancer Screening and Intervention Trial (LUSI) with a cancer-suspicious lung lesion in CT were examined with non-contrast-enhanced MRI of the lung at 1.5 T. Data were pseudonymized and presented at random order together with 30 datasets (23 in men, 7 in women, 18–64 years) from healthy volunteers. Two radiologists read the data for the presence of nodules. Sensitivity and specificity were calculated. Gold standard was either histology or long-term follow-up. Contrast-to-Noise-Ratio (CNR) was measured for all detected lesions in all MRI sequences.

Results

Average maximum diameter of the lesions was 15 mm. Overall sensitivity and specificity of MRI were 48% (26/54) and 88% (29/33) compared to low-dose CT. Sensitivity of MRI was significantly higher for malignant nodules (78% (12.5/16)) than for benign ones (36% (13.5/38); P = 0.007). There was no statistically significant difference in sensitivity between nodules (benign and malignant) larger or smaller than 10 mm (P = 0.7). Inter observer agreement was 84% (κ = 0.65). Lesion-to-background CNR of T2-weighted single-shot turbo-spin-echo was significantly higher for malignant nodules (89 ± 27) than for benign ones (56 ± 23; P = 0.002).

Conclusion

The sensitivity of MRI for detection of malignant pulmonary nodules in a high-risk population is 78%. Due to its inherent soft tissue contrast, MRI is more sensitive to malignant nodules than to benign ones. MRI may therefore represent a useful test for early detection of lung cancer.  相似文献   

7.

Objectives

To find the best pairing of first and second reader at highest sensitivity for detecting lung nodules with CT at various dose levels.

Materials and methods

An anthropomorphic lung phantom and artificial lung nodules were used to simulate screening CT-examination at standard dose (100 mAs, 120 kVp) and 8 different low dose levels, using 120, 100 and 80 kVp combined with 100, 50 and 25 mAs. At each dose level 40 phantoms were randomly filled with 75 solid and 25 ground glass nodules (5–12 mm). Two radiologists and 3 different computer aided detection softwares (CAD) were paired to find the highest sensitivity.

Results

Sensitivities at standard dose were 92%, 90%, 84%, 79% and 73% for reader 1, 2, CAD1, CAD2, CAD3, respectively. Combined sensitivity for human readers 1 and 2 improved to 97%, (p1 = 0.063, p2 = 0.016). Highest sensitivities – between 97% and 99.0% – were achieved by combining any radiologist with any CAD at any dose level. Combining any two CADs, sensitivities between 85% and 88% were significantly lower than for radiologists combined with CAD (p < 0.03).

Conclusions

Combination of a human observer with any of the tested CAD systems provide optimal sensitivity for lung nodule detection even at reduced dose at 25 mAs/80 kVp.  相似文献   

8.

Background and purpose

The imaging characterization of thyroid nodules is mandatory to exclude malignancy. The purpose of this study is to evaluate the role of quantitative diffusion MRI and 1H MR spectroscopy in differentiation between benign and malignant Thyroid nodules.

Methods

From February 2012 to May 2013, prospective study was conducted on 25 patients with 41 thyroid nodules (11 males, 14 females, age range, 16–74 years with mean 45.3 years) collected from wards and clinics of Internal Medicine and General Surgery Departments, 20 healthy individuals as control cases were included in the study. 1.5-T 1H-MR spectroscopy (at echo-times (TE) 144 and 35 ms) and diffusion-weighted imaging (b value 0, 250 and 1000 s/mm2) were performed and the results were correlated with histopathological results.

Results

The mean ADC of the malignant thyroid nodules (13 nodules) was 0.59 ± 0.24 × 10−3 mm2/s while that of the benign thyroid nodules (28 nodules) was 1.78 ± 0.21 × 10−3 mm2/s (p value <0.0001).Choline is present in all malignant nodules (13 nodules) and two benign nodules (mild elevation) while absent in 26 other benign nodules. Choline/creatine ratio in malignant nodules ranged from 1.3 to 5.4, while in two benign nodules it was 0.9 and 1.1.The sensitivity, specificity, PPV, NPV and overall accuracy of diffusion and MRS in differentiating benign from malignant thyroid nodules were 100%, 93%, 96%, 100% and 79%, respectively.

Conclusion

MRS and diffusion WI are useful noninvasive diagnostic modalities in differentiation between benign and malignant thyroid nodules.  相似文献   

9.

Objectives

To assess the effect of bone suppression imaging on observer performance in detecting lung nodules in chest radiographs.

Materials and methods

Posteroanterior (PA) and lateral digital chest radiographs of 111 (average age 65) patients with a CT proven solitary nodule (median diameter 15 mm), and 189 (average age 63) controls were read by 5 radiologists and 3 residents. Conspicuity of nodules on the radiographs was classified in obvious (n = 32), moderate (n = 32), subtle (n = 29) and very subtle (n = 18). Observers read the PA and lateral chest radiographs without and with an additional PA bone suppressed image (BSI) (ClearRead Bone Suppression 2.4, Riverain Technologies, Ohio) within one reading session. Multi reader multi case (MRMC) receiver operating characteristics (ROC) were used for statistical analysis.

Results

ROC analysis showed improved detection with use of BSI compared to chest radiographs alone (AUC = 0.883 versus 0.855; p = 0.004). Performance also increased at high specificities exceeding 80% (pAUC = 0.136 versus 0.124; p = 0.0007). Operating at a specificity of 90%, sensitivity increased with BSI from 66% to 71% (p = 0.0004). Increase of detection performance was highest for nodules with moderate and subtle conspicuity (p = 0.02; p = 0.03).

Conclusion

Bone suppressed images improve radiologists’ detection performance for pulmonary nodules, especially for those of moderate and subtle conspicuity.  相似文献   

10.

Objectives

The aim of our work was to determine the frequency of various cardiovascular abnormalities and atypical aspects observed in Tunisian competitive athletes.

Material and methods

Our population was constituted of 181 professional football players (average age 23.1 ± 3.9 years) consulted in “Centre National de la Médecine et des Sciences de Sport” of Tunis with to obtain medical certificate authorizing professional football practice.

Results

Electrocardiogram was strictly normal in 67 players (37%). Twenty-nine players had conduction abnormalities. Repolarisation abnormalities were noted in 20 players. Echocardiography was normal in 129 players (71.3%). Ten cases of valvular heart disease were found. The mean left ventricular end-diastolic diameter was 53 ± 4 mm and the mean left ventricular mass was 202.6 ± 42.7 g. The mean relative wall thickness was 0.380. The left ventricular hypertrophy was present in 42 players.

Conclusion

Cardiovascular abnormalities found in electrocardiogram and echocardiography in the Tunisian professional football players are comparable with those usually observed in elite athletes.  相似文献   

11.

Purpose

To evaluate the influence of radiation dose settings and reconstruction algorithms on the measurement accuracy and reproducibility of semi-automated pulmonary nodule volumetry.

Materials and methods

CT scans were performed on a chest phantom containing various nodules (10 and 12 mm; +100, −630 and −800 HU) at 120 kVp with tube current–time settings of 10, 20, 50, and 100 mAs. Each CT was reconstructed using filtered back projection (FBP), iDose4 and iterative model reconstruction (IMR). Semi-automated volumetry was performed by two radiologists using commercial volumetry software for nodules at each CT dataset. Noise, contrast-to-noise ratio and signal-to-noise ratio of CT images were also obtained. The absolute percentage measurement errors and differences were then calculated for volume and mass. The influence of radiation dose and reconstruction algorithm on measurement accuracy, reproducibility and objective image quality metrics was analyzed using generalized estimating equations.

Results

Measurement accuracy and reproducibility of nodule volume and mass were not significantly associated with CT radiation dose settings or reconstruction algorithms (p > 0.05). Objective image quality metrics of CT images were superior in IMR than in FBP or iDose4 at all radiation dose settings (p < 0.05).

Conclusion

Semi-automated nodule volumetry can be applied to low- or ultralow-dose chest CT with usage of a novel iterative reconstruction algorithm without losing measurement accuracy and reproducibility.  相似文献   

12.

Purpose

To evaluate the clinical utility and limitations of a computer software program for detecting tumor feeders of hepatocellular carcinoma (HCC) during transarterial chemoembolization (TACE).

Materials and methods

Forty-six patients with 59 HCC nodules underwent nonselective digital subtraction angiography (DSA) and C-arm computed tomography (CT) in the same hepatic artery. C-arm CT data sets were analyzed using the software to identify potential tumor feeders during each TACE session. For DSA analysis, 3 radiologists were independently assigned to identify tumor feeders using the DSA images in a separate session. The sensitivity of the 2 techniques in detecting tumor feeders was compared, with TACE findings as the reference standard. Factors affecting the failure of the software to detect tumor feeders were assessed by univariate and multivariate analyses.

Results

We detected 65 tumor feeders supplying 59 HCC nodules during TACE sessions. The sensitivity of the software to detect tumor feeders was significantly higher than that of the manual assessment using DSA (87.7% vs. 71.8%, P < 0.001). Multivariate analysis showed that a tumor feeder diameter of <1.0 mm (hazard ratio [HR], 56.3; P = 0.003) and lipiodol accumulation adjacent to the tumor (HR, 11.4; P = 0.044) were the significant predictors for failure to detect tumor feeders.

Conclusion

The software analysis was superior to manual assessment with DSA in detecting tumor feeders during TACE for HCC. However, the capability of the software to detect tumor feeders was limited by vessel caliber and by prior lipiodol accumulation to the tumor.  相似文献   

13.

Purpose

“Misty mesentery” is a CT appearance of mesenteric fat changes with increased attenuation often existing with swelled mesenteric lymph nodes. We evaluated diagnostic performance of FDG-PET/CT in distinguishing viable malignant disorders from benign conditions in misty mesentery.

Materials and methods

4236 FDG-PET/CT images were reviewed to identify patients with appearances of misty mesentery. Only the initial examinations were evaluated. Patients undergoing chemotherapy and/or radiotherapy within 3 months, patients with bulky mesenteric mass, and patients without follow-up examinations were excluded. Maximum short-axis diameter of mesenteric nodules (Diam-max) and maximum standardized uptake value (SUVmax) for mesenteric abnormalities were measured, and the diagnostic performance to differentiate between viable malignancy and stable lesions was assessed by receiver-operating characteristic (ROC) analysis, based on final diagnoses obtained by histology or follow-up examinations. Their significance was assessed by multivariate logistic regression.

Results

71 studies met the inclusion criteria with confirmed diagnoses (13 viable malignancies; 58 stable lesions). Of the 13 malignant cases, 12 were lymphoma. ROC curves indicated an optimal Diam-max cut-off value of >10 mm and SUVmax cut-off of ≥3.0, with area under the curve of 0.961 and 0.926, respectively. Using the optimal Diam-max cut-off, sensitivity and specificity were 69% and 98%, respectively. Using the optimal SUVmax cut-off, they were 85% and 98%, respectively. The combination of either Diam-max > 10 mm or SUVmax ≥ 3.0 had a sensitivity of 92%. Both Diam-max and SUVmax were significant independent factors for predicting malignancy.

Conclusions

FDG-PET/CT is feasible for identifying viable malignancy in misty mesentery.  相似文献   

14.

Objectives

To evaluate hability of a threshold value in ShearWave™ elastography to rule out malignant thyroid nodules while studying its pertinence in association with morphological signs.

Equipment and methods

148 patients (110 women and 38 men; 52.5 y.o. 15.8) referred for surgery of thyroid nodules underwent standard ultrasound as well as elastography. Characteristics of the morphological signs and maximum elastographic index were calculated in relation to histology. Association of morphological signs alone and then of elastography was also evaluated. One hundred and fifty one nodules were studied on a double-blind basis.

Results

297 nodules were studied. Thirty-five cancers were detected (11.6%). Elastographic index was higher in malignant nodules (115 kPa 60.4) than in benign nodules (41 kPa 25.8) (p < 0.001, Student's t-test). Cut off value of 66 kPa was the best to discriminate malignant nodules with a sensitivity of 80% (CI 95%, 62.5; 90.9) and a specificity of 90.5% (CI 95%, 86.1; 93.6) (p = 0.0001). Association of elastography and morphological ultrasound signs presented a sensitivity of 97% (CI 95%, 83.3; 99.8) and a negative predictive value of 99.5% (CI 95%, 95.6; 99.9). Interobserver reproducibility proved to be excellent with an interclass correlation of 0.97 (CI 95%, 0.96; 0.98) (p < 0.001).

Conclusion

The 66 kPa threshold in Shear Wave elastography is the best ultrasound sign to rule out malignant thyroid nodules. The method is simple, quantitative, reproducible and usable in the study of nodules larger than 3 cm. Progress must still be made in the study of calcified nodules and follicular tumors.  相似文献   

15.

Objective

To comparatively evaluate shear wave elastography (SWE) and real-time elastography (RTE) in distinguishing malignant from benign thyroid nodules.

Methods

49 patients with 64 focal thyroid nodules were enrolled and underwent SWE and RTE before surgery. SWE elasticity indices (mean, minimum and maximum value of 2-mm region of interest) of nodules were measured. For RTE, elastograms were assessed by Rago criteria and nodules with scores of 4 or 5 were classified as suspicious for malignancy. Surgery histopathologic results were adopted as diagnostic standard.

Results

Of the 64 nodules, 19 were papillary thyroid carcinomas and 45 were benign. SWE indices were significantly higher in malignant than benign nodules (P < 0.05). Areas under the ROC curves (AUC) of SWE parameters were 0.840, 0.831 and 0.788, which were not significantly different from that of RTE showed as 0.880 (P = 0.148–0.482). When the most accurate cut-off, 38.3 kPa for mean value was applied to predict malignancy, the diagnostic specificity, sensitivity, accuracy, positive predictive value and negative predictive value of SWE and RTE were 68.4% versus 79.0%, 86.7% versus 84.4%, 81.3% versus 78.1%, 68.4% versus 64.7% and 86.7% versus 83.3%, respectively (P = 0.683–1.000).

Conclusion

SWE as a promising tool can be performed in differentiating thyroid nodules with comparable results to RTE.  相似文献   

16.

Objective

To explore the efficacy of thyroid ultrasound (US) elastography in differential diagnosis of small thyroid nodules.

Methods

This HIPAA-compliant study was approved by the Institutional Review Board and all patients provided written informed consent. Thirty-five patients with 38 small thyroid nodules as seen on transverse ultrasound image formed our study population. An US examination and a separate thyroid elastography examination with pulsation from the carotid artery used as the compression source were performed before fine-needle aspiration. Baseband US data were acquired for off-line elastography processing, where a semi-quantitative index for each nodule was calculated. The Kruskal–Wallis nonparametric rank sum test was used to assess equality of population means among the different types of thyroid nodules. Maximum likelihood estimation of the curve parameters for a binomial receiver operating characteristic (ROC) curve was performed.

Results

Elasticity contrast index calculated with elastography was effective in distinguishing between small papillary thyroid carcinomas (PTMC, n = 8) and other lesions (n = 30) in small thyroid nodules (p = 0.0036). The area under the ROC curve for diagnosing PTMCs was 0.812 with a 95% confidence interval of 0.653–0.920. The cut-off value of ECI of 3.6 led to a sensitivity of 100% and a specificity of 60% for detecting PTMCs.

Conclusion

Noninvasive evaluation of small thyroid nodules is possible using thyroid US elastography with in vivo compression to pick out the most suspicious thyroid nodules for fine-needle aspiration (FNA) and avoid FNA in benign nodules.  相似文献   

17.

Objectives

The aim of this study was to investigate the value of shear wave velocity value (SWV) and shear wave velocity ratio (SWR) in differentiating between malignant and benign thyroid nodules using virtual touch tissue quantification (VTQ) of acoustic radiation force impulse (ARFI) technology.

Methods

The SWV and SWR were analyzed in 155 thyroid nodules in 155 patients (93 benign and 62 malignant) and eighty normal thyroid glands. The diagnostic performance of SWV and SWR were compared.

Results

The mean value of SWV of malignant nodules differed significantly from those of the benign nodules (6.34 ± 2.58 m/s vs. 2.15 ± 0.59 m/s, P < 0.05) and the normal thyroid (1.96 ± 0.31 m/s, P < 0.05). There was no statistically significant difference between the mean value of SWV of benign nodules and normal thyroid (P > 0.05). The mean value of SWR of malignant nodules differed significantly from those of the benign nodules (2.99 ± 1.45 vs. 1.07 ± 0.34, P < 0.05). The sensitivity, specificity, positive predictive values, negative predictive values and accuracy of SWV in differentiating between malignant and benign nodules were 96.80%, 95.70%, 93.75%, 97.80% and 96.13% respectively based on the cutoff point as 2.84 m/s. Those of SWR were 91.90%, 81.70%, 77.03%, 93.83% and 85.83% based on the cutoff point as 1.32. The diagnostic accuracy rate of SWV was statistically higher than that of SWR (P < 0.05).

Conclusion

VTQ of ARFI technology provides the quantitative information of thyroid tissue elasticity and has high accuracy rate in differentiating between malignant and benign nodules. It is a useful complement for conventional ultrasonography.  相似文献   

18.

Objective

Microwave ablation is a minimally invasive technique that has been used to treat benign and malignant tumors of liver, lung and kidney. Towards thyroid nodules, only a few cases are reported so far. The aim of the study was to investigate the effectiveness and safety of ultrasound-guided percutaneous microwave ablation in the treatment of benign thyroid nodules with a large sample.

Materials and methods

A total of 477 benign thyroid nodules in 222 patients underwent microwave ablation in our department from July 2009 to March 2012. Microwave ablation was carried out using microwave antenna (16G) under local anesthesia. Nodule volume, thyroid function and clinical symptoms were evaluated before treatment and at 1, 3, more than 6 months. The study was ethics committee approved and written informed consents were obtained from all patients.

Results

All thyroid nodules significantly decreased in size after microwave ablation. A 6-month follow-up was achieved in 254 of 477 nodules, and the mean decrease in the volume of thyroid nodules was from 2.13 ± 4.42 ml to 0.45 ± 0.90 ml, with a mean percent decrease of 0.65 ± 0.65. A volume-reduction ratio greater than 50% was observed in 82.3% (209/254) of index nodules, and 30.7% (78/254) of index nodules disappeared 6-month after the ablation. The treatment was well tolerated and no major complications were observed except pain and transient voice changes.

Conclusions

Microwave ablation seems to be a safe and effective technique for the treatment of benign thyroid nodules. Further prospective randomized studies are needed to define the role of the procedure in the treatment of thyroid nodules.  相似文献   

19.

Aim of the work

To study the diagnostic utility of real-time ultrasound elastography (USE) in predicting malignancy in thyroid nodules.

Materials and methods

Forty-five patients with solitary solid thyroid nodules were included in this study. The thyroid nodules were examined by B-mode ultrasound, color flow Doppler ultrasound, and real-time ultrasound elastography (USE). The final diagnosis was obtained from histopathological findings. Tissue stiffness on USE was scored from 1 (low stiffness over the entire nodule) to 6 (high stiffness over the entire nodule and surrounding tissue).

Results

Twenty-eight (62.2%) patients had a final diagnosis of malignancy based on histopathological evidence of malignant thyroid nodules, while 17 (37.8%) were diagnosed as benign nodules. Anteroposterior/transverse (AP/T) diameter more than 1 cm, ill-defined margins and spot micro calcifications were the most predictive conventional ultrasound patterns of malignancy. Elasticity score of 4–6 was highly predictive of malignancy (P < 0.0001), with a sensitivity of 89.3%, a specificity of 88.2% and an accuracy of 88.9%.

Conclusion

Ultrasound elastography is an accurate non invasive tool for evaluating thyroid nodules. It has more appropriate value in the differential diagnosis of thyroid malignancy and enhances the diagnostic assurance of ultrasonographers.  相似文献   

20.

Objective

This study aims to evaluate the clinical value of ultrasound elastography (USE) in providing information on the nature of the thyroid nodules. This was performed using the elastography score and strain ratio in differentiating thyroid benign and malignant nodules and the histopathological examination was used as the diagnostic standard of reference.

Methods

We examined 84 thyroid nodules in 62 patients with ultrasound elastography. Elastography score was assigned based on a four-point scale according to the classification proposed by Itoh et al. with a score of 1 (low stiffness over the entire nodule) to a score of 4 (high stiffness over the entire nodule). Thyroid strain ratio (normal tissue to lesion strain ratio) was calculated. Histopathological results were the standard reference. The area under the curve (AUC) and the best cut-off point were both obtained using receiver-operating characteristic (ROC) curve analysis. The sensitivity, specificity, and accuracy of both techniques were calculated.

Results

Fifty-four of the 84 nodules had scores of 1 and 2, and 50 of these nodules were diagnosed histopathologically as benign. Thirty of the 84 nodules had a score of 3 and 4, and 21 of these nodules were diagnosed histopathologically as malignant. The scores of 1 and 2 with Itoh criteria were significantly seen in benign nodules, whereas, scores of 3 and 4 were significantly seen in malignant nodules (p < 0.05) with sensitivity 84%, specificity 84.7%, PPV 70%, NPV 92.6% and accuracy 84.5%. The mean SR for the benign nodules and malignant ones was significantly different (2.92 ± 0.96 vs. 4.53 ± 0.82, p < 0.001). With ROC analysis, the best cut-off strain ratio point was 3.5 for differentiating benign and malignant nodules with area under the curve (AUC) = 0.87 (0.8–0.95). The sensitivity of the strain ratio was 88%, while the specificity was 86.4%, PPV = 73.3%, NPV = 94.4% and accuracy = 86.9%.

Conclusions

Both the elastographic score and strain ratio are higher in malignant nodules than those in benign ones. Ultrasound elastography can provide quantitative information on thyroid nodule helping in differentiating benign and malignant ones.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号