Purpose

To assess the clinical value of retrospective image fusion of neck MRI and 18F-fluorodeoxyglucose (18F-FDG) PET for locoregional extension and nodal staging of neck cancer.

Materials and methods

Thirty patients with carcinoma of the oral cavity or hypopharynx underwent PET/CT and contrast-enhanced neck MRI for initial staging before surgery including primary tumor resection and neck dissection. Diagnostic performance of PET/CT, MRI, and retrospective image fusion of PET and MRI (fused PET/MRI) for assessment of the extent of the primary tumor (T stage) and metastasis to regional lymph nodes (N stage) was evaluated.

Results

Accuracy for T status was 87% for fused PET/MRI and 90% for MRI, thus proving significantly superior to PET/CT, which had an accuracy of 67% (p = 0.041 and p = 0.023, respectively). Accuracy for N status was 77% for both fused PET/MRI and PET/CT, being superior to MRI, which had an accuracy of 63%, although the difference was not significant (p = 0.13). On a per-level basis, the sensitivity, specificity and accuracy for detection of nodal metastasis were 77%, 96% and 93% for both fused PET/MRI and PET/CT, compared with 49%, 99% and 91% for MRI, respectively. The differences for sensitivity (p = 0.0026) and accuracy (p = 0.041) were significant.

Conclusion

Fused PET/MRI combining the individual advantages of MRI and PET is a valuable technique for assessment of staging neck cancer.  相似文献   

2.

Purpose

To prospectively evaluate the diagnostic performance of magnetic resonance imaging (MRI), 11C-acetate positron emission tomography/computed tomography (PET/CT) and contrast-enhanced CT for bladder cancer staging, using whole-mount pathologic review of radical cystectomy and pelvic lymph node specimens as the reference standard.

Materials and methods

The institutional review board approved this prospective study, which was compliant with the Health Insurance Portability and Accountability Act. Written informed consent was obtained from 16 patients with histologically confirmed bladder cancer who underwent MRI, 11C-acetate PET/CT and contrast-enhanced CT before radical cystectomy and pelvic lymph node dissection. Before imaging 4/16 patients had received intravesical Bacillus Calmette-Guérin treatment, 6 had received systemic chemotherapy, 3 had received both and 3 had received neither. Measures of diagnostic performance including accuracy, sensitivity and specificity were estimated separately for each imaging modality.

Results

MRI correctly staged 56% of patients (9/16), overstaged 38% (6/16) and understaged 6% (1/16). CT correctly staged 50% of patients (8/16), overstaged 44% (7/16) and understaged 6% (1/16). In 9 patients, 11C-acetate PET/CT showed uptake within the bladder wall; the uptake was true-positive in 7 patients and false-positive in 2 patients. Of the remaining 7 patients, 5 had true-negative and 2 had false-negative PET/CT results for cancer in the bladder wall. For all modalities, staging accuracy was reduced in patients with a history of prior intravesical and/or systemic chemotherapy.

Conclusion

In staging bladder cancer, MRI, 11C-acetate PET/CT and CT displayed similar levels of accuracy. For all modalities, a history of intravesical and/or systemic chemotherapy affected staging accuracy.  相似文献   

3.

Background

To evaluate the diagnostic value of retrospective image fusion from pelvic magnetic resonance imaging (MRI) and 18F-fluorodeoxyglucose positron emission tomography (PET) in detecting intra-pelvic recurrence of gynecological tumor.

Methods

Thirty patients with a suspicion of recurrence of gynecological malignancy underwent inline contrast-enhanced PET/computed tomography (CT) and pelvic contrast-enhanced MRI for restaging. Diagnostic performance about the local recurrence, pelvic lymph node and bone metastasis and peritoneal lesion of PET/low-dose non-enhanced CT (PET/ldCT), PET/full-dose contrast-enhanced CT (PET/ceCT), contrast-enhanced MRI, and retrospective image fusion from PET and MRI (fused PET/MRI) were evaluated by two experienced readers. Final diagnoses were obtained by histopathological examinations, radiological imaging and clinical follow-up for at least 6 months. McNemar test was employed for statistical analysis.

Results

Documented positive locally recurrent disease, pelvic lymph node and bone metastases, and peritoneal dissemination were present in 53.3, 26.7, 10.0, and 16.7 %, respectively. Patient-based sensitivity for detecting local recurrence, pelvic lymph node and bone metastasis and peritoneal lesion were 87.5, 87.5, 100 and 80.0 %, respectively, for fused PET/MRI, 87.5, 62.5, 66.7 and 60.0 %, respectively, for contrast-enhanced MRI, 62.5, 87.5, 66.7 and 80.0 %, respectively, for PET/ceCT, and 50.0, 87.5, 66.7 and 60.0 %, respectively, for PET/ldCT. The sensitivity of diagnosing local recurrence by fused PET/MRI was significantly better than that of PET/ldCT (p = 0.041). The patient-based sensitivity, specificity and accuracy for the detection of intra-pelvic recurrence/metastasis were 91.3, 100 and 93.3 % for fused PET/MRI, 82.6, 100 and 86.7 % for contrast-enhanced MRI, 82.6, 100 and 86.7 % for PET/ceCT and 78.3, 85.7 and 80.0 % for PET/ldCT.

Conclusion

Fused PET/MRI combines the individual advantages of MRI and PET, and is a valuable technique for assessment of intra-pelvic recurrence of gynecological cancers.  相似文献   

4.

Objective

To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated 18F-fluorodeoxyglucose (FDG)-PET/CT studies for restaging of ovarian cancer.

Materials and methods

One hundred and twenty women who had undergone treatment for ovarian cancer underwent a conventional PET/CT scans with ldCT, and then ceCT. Two observers interpreted and decided in consensus on the PET/ldCT and PET/ceCT images by a 3-point scale (N: negative, E: equivocal, P: positive) per patient and lesion site. Final diagnoses were obtained by histopathological examinations, or clinical follow-up for at least 6 months.

Results

Patient-based analysis showed that the sensitivity, specificity, and accuracy of PET/ceCT was 86.9% (40/46), 95.9% (71/74), and 92.5% (111/120), respectively, whereas those of PET/ldCT were 78.3% (36/46), 95.0% (70/74), and 88.3% (106/120), respectively. All sensitivity, specificity, and accuracy significantly differed between two methods (McNemar test, p < 0.0005, p = 0.023, and p < 0.0001, respectively). The scales of detecting 104 recurrent lesion sites were N:14, E:6, P:84 for PET/ceCT, and N:15, E:17, P:72 for PET/ldCT, respectively. Eleven equivocal and one negative regions by PET/ldCT were correctly interpreted as positive by PET/ceCT.

Conclusion

PET/ceCT is a more accurate imaging modality with higher confidence for assessing ovarian cancer recurrence than PET/ldCT.  相似文献   

5.
《Clinical imaging》2014,38(4):464-469
PurposeTo investigate the fusion of pelvic magnetic resonance imaging (MRI) and fluorodeoxyglucose positron emission tomography (PET) for assessment of locoregional extension and nodal staging of cervical cancer.MethodsPET/computed tomography (CT), MRI, and non-fused and fusion of PET and MRI for assessing the extent of the primary tumor and metastasis to nodes were evaluated.ResultsAccuracy for T-status was 83.3% for fused and non-fused PET/MRI and MRI proved significantly more accurate than PET/CT (53.3%) (P= .0077). Sensitivity, specificity, and accuracy for nodal metastasis were 92.3%, 88.2%, and 90.0% for fused PET/MRI and PET/contrast-enhanced CT; 84.6%, 94.1%, and 90.0% for non-fused PET/MRI; and 69.2%, 100%, and 86.7% for MRI.ConclusionFused PET/MRI combines the individual advantages of MRI and PET.  相似文献   

6.

Objectives

To assess the value of PET/MRI with [18F]-FDG using a whole body protocol for the depiction and characterization of liver lesions in comparison to PET/CT.

Methods

70 patients (31 women, 39 men) with solid tumors underwent [18F]-FDG PET/CT and followed by an additional PET/MRI using an integrated scanner. Two readers rated the datasets (PET/CT; PET/MRI) regarding conspicuity of hepatic lesions (4-point ordinal scale) and diagnostic confidence (5-point ordinal scale). Median scores for lesion conspicuity and diagnostic confidence were compared using Wilcoxon's rank sum test. Prior examinations, histopathology and clinical follow-up (116 ± 54 days) served as standard of reference.

Results

36 of 70 (51%) patients showed liver lesions. Using PET/CT and PET/MRI all patients with liver metastases could correctly be identified. A total of 97 lesions were found (malignant n = 26; benign n = 71). For lesion conspicuity significantly higher scores were obtained for PET/MRI in comparison to PET/CT (p < 0.001). Significantly better performance for diagnostic confidence was observed in PET/MRI, both for malignant as for benign lesions (p < 0.001).

Conclusions

PET/MRI, even in the setting of a whole body approach, provides higher lesion conspicuity and diagnostic confidence compared to PET/CT and may therefore evolve as an attractive alternative in oncologic imaging.  相似文献   

7.

Objectives

We aimed to study the ability of contrast enhanced MRI at 1.5 T and 11C-acetate PET/CT, both individually and using fused data, to detect localized prostate cancer.

Methods

Thirty-six men with untreated prostate cancer and negative for metastatic disease on pelvic CT and bone scan were prospectively enrolled. A pelvic 11C-acetate PET/CT scan was performed in all patients, and a contrast enhanced MRI scan in 33 patients (6 examinations using both endorectal coil and surface coils, and 27 examinations using surface coils only). After the imaging studies 10 patients underwent prostatectomy and 26 were treated by image guided external beam radiation treatment. Image fusion of co-registered PET and MRI data was performed based on anatomical landmarks visible on CT and MRI using an advanced in-house developed software package. PET/CT, MRI and fused PET/MRI data were evaluated visually and compared with biopsy findings on a lobar level, while a sextant approach was used for patients undergoing prostatectomy.

Results

When using biopsy samples as method of reference, the sensitivity, specificity and accuracy for visual detection of prostate cancer on a lobar level by contrast enhanced MRI was 85%, 37%, 73% and that of 11C-acetate PET/CT 88%, 41%, 74%, respectively. Fusion of PET with MRI data increased sensitivity, specificity and accuracy to 90%, 72% and 85%, respectively.

Conclusions

Fusion of sequentially obtained PET/CT and MRI data for the localization of prostate cancer is feasible and superior to the performance of each individual modality alone.  相似文献   

8.

Purpose

The aim of this study was to investigate the potential impact of PET/CT on the initial staging of lymphoma with comparison to each of the PET and CT components alone.

Materials and methods

PET/CTs from 37 patients with lymphoma undergoing initial staging were studied. Review of PET, CT and PET/CT images were done and staging of each patient by each modality was assigned and compared together. Clinical follow-up, additional imaging and histology served as the standard of reference.

Results

PET/CT correctly diagnosed 83 nodal regions as positive for lymphomatous involvement versus 61 and 57 detected by PET and CT respectively. The respective sensitivities, specificities, and accuracies for the detection of nodal involvement were: PET: 88.4%, 65%, 94%, CT 89.1%, 60.1%, 96.1%, PET/CT 96.3%, 88.3%, 98.2%. PET/CT also correctly identified more extra-nodal lesions (n = 24) than CT (n = 16) and PET (n = 15). Correct staging was more accurate at PET/CT (n = 31) in comparison to PET alone (n = 23) and CT alone (n = 21).

Conclusions

PET/CT was superior to PET and CT in the initial staging of lymphoma with significant better performance compared to PET and CT to clarify nodal and extra-nodal involved sites. The application of PET/CT rather than CT or PET is likely to be more beneficial.  相似文献   

9.

Purpose

Our aim was to clarify the diagnostic impact of contrast-enhanced (CE) 18F-fluorodeoxyglucose (FDG)–positron emission tomography (PET)/computed tomography (CT) for staging of pancreatic cancer compared to non-CE PET/CT.

Method and materials

Between April 2006 and November 2009, a total of 95 patients (age range, 36–83 years [mean age, 67]) with primary pancreatic cancer underwent 18F-FDG PET/CT examinations. Diagnostic accuracy was compared between non-CE PET/CT and CE PET/CT. Images were analyzed visually and quantitatively by two blinded reviewers. Reference standard was histological examination in 48 patients (51%) and/or confirmation of an obvious progression in number and/or size of the lesions on follow-up CT examinations in 47 patients (49%).

Results

For T-staging, invasion of duodenum (n = 20, 21%), mesentery (n = 12, 13%), and retroperitoneum (n = 13, 14%) was correctly diagnosed by both modalities. The ROC analyses revealed that the Az values of celiac artery (CA), common hepatic artery (CHA), splenic artery (SV), and superior mesenteric vein (SMV) invasion were significantly higher in the CE PET/CT group for both readers. Nodal metastasis was correctly diagnosed by CE PET/CT in 38 patients (88%) and by non-CE PET/CT in 45 patients (87%). Diagnostic accuracies of nodal metastasis in two modalities were similar. Using CE PET/CT, distant metastasis, scalene node metastasis, and peritoneal dissemination were correctly assigned in 39 patients (91%), while interpretation based on non-CE PET/CT revealed distant metastasis, scalene node metastasis, and peritoneal dissemination in 42 patients (81%). Diagnostic accuracy of distant metastasis, scalene node metastasis, and peritoneal dissemination with CE PET/CT was significantly higher than that of non-CE PET/CT (p < 0.05).

Conclusion

CE PET/CT allows a more precise assessment of distant metastasis, scalene node metastasis, and peritoneal dissemination in patients with pancreatic cancer.  相似文献   

10.

Purpose

To compare the performance of PET/MRI imaging using MR attenuation correction (MRAC) (DIXON-based 4-segment -map) in breast cancer patients with that of PET/CT using CT-based attenuation correction and to compare the quantification accuracy in lesions and in normal organ tissues.

Methods

A total of 36 patients underwent a whole-body PET/CT scan 1 h after injection and an average of 62 min later a second scan using a hybrid PET/MRI system. PET/MRI and PET/CT were compared visually by rating anatomic allocation and image contrast. Regional tracer uptake in lesions was quantified using volumes of interest, and maximal and mean standardized uptake values (SUVmax and SUVmean, respectively) were calculated. Metabolic tumor volume (MTV) of each lesion was computed on PET/MRI and PET/CT. Tracer uptake in normal organ tissue was assessed as SUVmax and SUVmean in liver, spleen, left ventricular myocardium, lung, and muscle.

Results

Overall 74 FDG positive lesions were visualized by both PET/CT and PET/MRI. No significant differences in anatomic allocation scores were found between PET/CT and PERT/MRI, while contrast score of lesions on PET/MRI was significantly higher. Both SUVmax and SUVmean of lesions were significantly higher on PET/MRI than on PET/CT, with strong correlations between PET/MRI and PET/CT data (ρ = 0.71–0.88). MTVs of all lesions were 4% lower on PET/MRI than on PET/CT, but no statistically significant difference was observed, and an excellent correlation between measurements of MTV with PET/MRI and PET/CT was found (ρ = 0.95–0.97; p < 0.0001). Both SUVmax and SUVmean were significantly lower by PET/MRI than by PET/CT for lung, liver and muscle, no significant difference was observed for spleen, while either SUVmax and SUVmean of myocardium were significantly higher by PET/MRI. High correlations were found between PET/MRI and PET/CT for both SUVmax and SUVmean of the left ventricular myocardium (ρ = 0.91; p < 0.0001), while moderate correlations were found for the other normal organ tissues (ρ = 0.36–0.61; p < 0.05).

Conclusions

PET/MRI showed equivalent performance in terms of qualitative lesion detection to PET/CT. Despite significant differences in tracer uptake quantification, due to either methodological and biological factors, PET/MRI and PET/CT measurements in lesions and normal organ tissues correlated well. This study demonstrates that integrated whole-body PET/MRI is feasible in a clinical setting with high quality and in a short examination time.  相似文献   

11.

Objective

To detect accuracy of PET/CT in the initial staging, response after the first line and end of treatment in early mediastinal lymphoma patients compared to contrast CT.

Materials and methods

We studied 50 patients with pathologically proven lymphoma with a mean age = 27.5. All patients were at early stage. All patients performed CT and PET/CT for initial staging, after the first course of chemotherapy (after 4–6 weeks) and at the end of treatment (after 2–4 months).

Results

PET/CT upstaged 5 cases. At first line of treatment, PET/CT and CECT were agreeable in 32% of cases. PET/CT showed 100% sensitivity, 96.7% specificity, 95% positive predictive value and 100% negative predictive value. At the end of treatment both methods showed a 46% agreement. PET/CT was statistically significant in the follow up of hilar and axillary lymph nodes. PET/CT showed 100% sensitivity and specificity; compared to 62.5% sensitivity and 97.6% specificity for CECT in detection of extra-nodal disease sites.

Conclusion

PET/CT proved higher sensitivity and specificity over CECT. The major strength of PET/CT over CECT was its higher ability for detection of extra-nodal sites of lymphoma and excluding active disease in residual nodal mass lesions on follow up.  相似文献   

12.

Purpose

Simultaneous brain PET/MRI faces an important issue of validation of accurate MRI based attenuation correction (AC) method for precise quantitation of brain PET data unlike in PET/CT systems where the use of standard, validated CT based AC is routinely available. The aim of this study was to investigate the feasibility of evaluation of semiquantitative 18F-FDG PET parameters derived from simultaneous brain PET/MRI using ultrashort echo time (UTE) sequences for AC and to assess their agreement with those obtained from PET/CT examination.

Methods

Sixteen patients (age range 18–73 years; mean age 49.43 (19.3) years; 13 men 3 women) underwent simultaneous brain PET/MRI followed immediately by PET/CT. Quantitative analysis of brain PET images obtained from both studies was undertaken using Scenium v.1 brain analysis software package. Twenty ROIs for various brain regions were system generated and 6 semiquantitative parameters including maximum standardized uptake value (SUV max), SUV mean, minimum SUV (SUV min), minimum standard deviation (SD min), maximum SD (SD max) and SD from mean were calculated for both sets of PET data for each patient. Intra-class correlation coefficients (ICCs) were determined to assess agreement between the various semiquantitative parameters for the two PET data sets.

Results

Intra-class co-relation between the two PET data sets for SUV max, SUV mean and SD max was highly significant (p < 0.00) for all the 20 predefined brain regions with ICC > 0.9. SD from mean was also found to be statistically significant for all the predefined brain regions with ICC > 0.8. However, SUV max and SUV mean values obtained from PET/MRI were significantly lower compared to those of PET/CT for all the predefined brain regions.

Conclusion

PET quantitation accuracy using the MRI based UTE sequences for AC in simultaneous brain PET/MRI is reliable in a clinical setting, being similar to that obtained using PET/CT.  相似文献   

13.

Purpose

Positron emission tomography/magnetic resonance imaging (PET/MRI) requires efficient scan protocols for whole-body cancer staging. The aim of this study was to evaluate if the application of diffusion-weighted MR imaging (DWI) results in a diagnostic benefit for lesion detection in oncologic patients if added to a whole-body [18F]-fluorodesoxyglucose ([18F]-FDG) PET/MRI protocol.

Methods

25 consecutive oncologic patients (16 men, 9 women; age 57 ± 12 years) prospectively underwent whole-body [18F]-FDG-PET/MRI including DWI on a hybrid PET/MRI scanner. A team of two readers assessed [18F]-FDG PET/MRI without DWI for primary tumors and metastases. In a second session, now considering DWI, readers reassessed [18F]-FDG PET/MRI accordingly. Additionally, the lesion-to-background contrast on [18F]-FDG PET and DWI was rated qualitatively (0, invisible; 1, low; 2, intermediate; 3, high). Wilcoxon's signed-rank test was performed to test for differences in the lesion-to-background contrast.

Results

49 lesions were detected in 16 patients (5 primaries, 44 metastases). All 49 lesions were concordantly detected by [18F]-FDG PET/MRI alone and [18F]-FDG PET/MRI with DWI. The lesion-to-background contrast on DWI compared to [18F]-FDG PET was rated lower in 22 (44.9%) of 49 detected lesions resulting in a significantly higher lesion-to-background contrast on [18F]-FDG PET compared to DWI (P = 0.001).

Conclusions

DWI as part of whole-body [18F]-FDG PET/MRI does not benefit lesion detection. Given the necessity to optimize imaging protocols with regard to patient comfort and efficacy, DWI has to be questioned as a standard tool for whole-body staging in oncologic PET/MRI.  相似文献   

14.

Purpose

The purpose of this study was to evaluate the role of integrated PET/CT in the staging of lung cancer compared with CT alone or PET alone.

Materials and methods

Thirty-three patients underwent integrated PET/CT for the staging of lung cancer. The tumor, node and metastasis (TNM) stages were assessed with CT, PET and integrated PET–CT and compared with the surgical and pathological staging.

Results

CT correctly evaluated the (T) status in (64%) of the patients, PET in (59%) and PET/CT in (86%). CT correctly evaluated the (N) status in (73%) of the patients, PET in (76%), and PET/CT (88%) with accuracy, sensitivity, specificity, PPV and NPV were 73%, 78%, 71%, 50% and 94% for CT, 76%, 67%, 79%, 55% and 95% for PET and 88%, 89%, 88%, 73% and 100% for PET/CT respectively, and for (M) status were 91%, 86%, 92%, 75% and 96% for CT, 88%, 71%, 92%, 71% and 92% for PET and 97%, 100%, 96%, 88% and 100% for PET/CT respectively. Regarding the overall TNM staging CT correctly staged 24 patients. PET correctly staged 23 cases while PET/CT correctly staged 30 cases. A significant difference in the accuracy of overall tumor staging between PET/CT and CT (P = 0.0412) or PET (P = 0.0233).

Conclusion

The integrated PET/CT is superior to either CT or PET in the staging of lung cancer which has an important impact on selection of the appropriate treatment regimen.  相似文献   

15.

Background and purpose

Evaluation of bone marrow infiltration is an essential step in the staging of lymphoma. The accuracy of 18F-fluorodeoxyglucose-positron emission tomography (18F-FDG PET), combined 18F-fluorodeoxyglucose-positron emission tomography/computed tomography (18F-FDG-PET/CT) and magnetic resonance imaging (MRI) in diagnosing bone marrow involvement of lymphoma has never been systematically assessed, and the present systematic review was aimed at this issue.

Methods

MEDLINE, EMBASE, Cochrane library and some other databases, from January 1995 to July 2010, were searched for initial studies. All the studies published in English or Chinese relating to the diagnostic value of 18F-FDG PET, PET/CT and MRI for patients with bone marrow involvement of lymphoma were collected. We extracted data to calculate sensitivity, specificity, SROC curves and AUC and to test for heterogeneity. The statistic software called “Meta-Disc 1.4” was used for data analysis.

Result

In 32 included studies, PET/CT had the highest pooled sensitivity, 91.6% (95%CI: 85.1, 95.9) and highest pooled specificity, 90.3% (95%CI: 85.9, 93.7). PET/CT also had the highest pooled DOR, 68.89 (95%CI: 15.88, 298.92). The AUC of PET, PET/CT, and MRI were 0.9430, 0.9505 and 0.8764. There was heterogeneity among studies and no evidence of publication bias.

Conclusion

PET/CT was a highly sensitive and specific modality in diagnosing patients with bone marrow involvement in lymphoma. Compared with MRI and PET alone, PET/CT can play important roles in the staging of lymphoma.  相似文献   

16.

Objective

To determine the associations of quantitative parameters derived from multiphase contrast-enhanced magnetic resonance imaging (CE-MRI), diffusion-weighted (DW) MRI and 18F-fluorodeoxyglucose (18F-FDG) positron-emission tomography/computed tomography (PET/CT) with clinico-histopathological prognostic factors, disease-free survival (DFS) and overall survival (OS) in patients with cervical cancer.

Methods and materials

Our institutional review board approved this retrospective study of 49 patients (median age, 45 years) with histopathologically proven IB-IVB International Federation of Gynecology and Obstetrics (FIGO) cervical cancer who underwent pre-treatment pelvic MRI and whole-body 18F-FDG PET/CT between February 2009 and May 2012. Maximum diameter (maxTD), percentage enhancement (PE) and mean apparent diffusion coefficient (ADCmean) of the primary tumor were measured on MRI. Maximum standardized uptake value (SUVmax), metabolic tumor volume (MTV), total lesion glycolysis (TLG) were measured on 18F-FDG PET/CT. Correlations between imaging metrics and clinico-histopathological parameters including revised 2009 FIGO stage, tumor histology, grade and lymph node (LN) metastasis at diagnosis were evaluated using the Wilcoxon rank sum test. Cox modeling was used to determine associations with DFS and OS.

Results

Median follow-up was 17 months. 41 patients (83.6%) were alive. 8 patients (16.3%) died of disease. Progression/recurrence occurred in 17 patients (34.6%). Significant differences were observed in ADCmean, SUVmax, MTV and TLG according to FIGO stage (p < 0.001–0.025). There were significant correlations between ADCmean, MTV, TLG and LN metastasis (p = 0.017–0.032). SUVmax was not associated with LN metastasis. FIGO stage (p = 0.017/0.033), LN metastases (p = 0.001/0.020), ADCmean (p = 0.007/0.020) and MTV (p = 0.014/0.026) were adverse predictors of both DFS/OS. maxTD (p = 0.005) and TLG (p = 0.024) were adverse predictors of DFS. PE and SUVmax did not correlate with DFS or OS (p = 0.18–0.72).

Conclusions

Quantitative parameters derived from pre-treatment DW-MRI (ADCmean) and from 18F-FDG PET/CT (MTV and TLG) were associated with high-risk features and may serve as prognostic biomarkers of survival in patients with cervical cancer.  相似文献   

17.

Purpose

To assess the value of contrast enhanced CT (ceCT) when added to positron emission tomography combined with the standard low-dose non-contrast CT (PET/CT) protocols for staging patients with malignant pleural mesothelioma (MPM).

Methods

Retrospective analysis of 47 patients with pathologically proved MPM. All patients underwent PET/CT with low dose CT followed by ceCT. PET/CT and ce-CT were evaluated separately then in combination. All the results were validated either by histopathology and/or clinical-radiological follow-up. Staging was performed based on TNM system.

Results

For T-stage, the sensitivities for PET/CT, ceCT and combined PET/CT-ceCT were 89.1%, 86.9%, and 97.5%, respectively, p = 0.04. Regarding nodal stage, the sensitivity, specificity and accuracy for PET/CT were 88.5%, 90.5%, and 89.4%; for ceCT 73.1%, 95.2% and 82.9%; and for PET/CT-ceCT 96.2%, 95.2% and 95.7%, respectively. PET/CT-ceCT significantly associated with the sensitivity, p = 0.05. Considering the metastatic disease, the sensitivity, specificity and accuracy for PET/CT were 81.3%, 96.8%, and 91.5%; for ceCT 56.3%, 90.3% and 78.7%; and for PET/CT-ceCT 93.8%, 96.8% and 95.7%, respectively. PET/CT-ceCT significantly improved the sensitivity (p = 0.03) and accuracy (p = 0.02). Furthermore, combined PET/CT-ceCT significantly identified patients not suitable for surgery.

Conclusion

The addition of ceCT to PET/CT protocol has significantly contributed to the staging of MPM.  相似文献   

18.

Objective

The purpose of this study was to assess the diagnostic value of PET/CT as a one step examination in patients with colorectal cancer. Therefore we proved whether diagnostic PET/CT adds information over PET or contrast-enhanced CT alone for staging or restaging of patients with colorectal cancer.

Methods

Seventy-three patients (46 males and 27 females; age range: 50-81 years; mean age: 67 years) with known colorectal cancer underwent 18F-FDG-PET/CT for staging or restaging.

Results

Of the 73 patients 26 patients underwent PET/CT for staging and 47 for restaging. 266 metastases could be detected in 60 patients. Contrast-enhanced PET/CT had a lesion-based sensitivity of 100%, contrast-enhanced CT of 91% and PET of 85%. PET/CT identified 2 lesions as false positive. PET/CT could also reach a patient-based sensitivity of 100%, which was superior to contrast-enhanced CT and PET.

Conclusion

Our study clearly demonstrated the added value of contrast-enhanced PET/CT in staging and restaging patients with colorectal cancer over CT and PET alone.  相似文献   

19.

Purpose

Evaluate the diagnostic performance of contrast enhanced CT/PET (ceCT/PET) in the response assessment of patients with colorectal cancer liver metastases.

Methods

33 ce CT/PET studies of 19 patients with colorectal liver metastases were prospectively evaluated. All of them, 13 (68.4%) were males and 6 (31.6%) females. Mean age and range were 63 [42–78]. All patients were treated with neoadjuvant chemotherapy. In all cases post-therapy diagnostic confirmation of liver lesions was obtained. A ce CT PET/was obtained 1 h after the injection of 370 MBq of 18F-FDG.Metabolic and morphologic studies were evaluated by two blinded nuclear physicians and radiologists respectively to assess the location, size and suspected diagnosis of lesions (benign or malignant). A combined assessment of both techniques was performed.The final diagnosis was established by histopathology or clinical/radiological follow-up greater than 6 months.

Results

A total of 120 liver lesions were identified, 115 were malignant and 5 benign.From the malignant lesions, 105 were identified with the ceCT, 44 with the PET and 109 with ceCT/PET. All of the benign lesions were correctly classified with any of the three imaging techniques.The sensitivity of PET, ceCT and ceCT/PET were of 38%, 91% and 95% respectively and the specificity was 100% in all three of the diagnostic studies.

Conclusion

Administration of intravenous contrast in the PET/CT is mandatory to evaluate treatment response rate of liver metastases due to the limitations of isolated metabolic images in these cases.  相似文献   

20.

Purpose

The new modality of an integrated positron emission tomography/magnetic resonance imaging (PET/MRI) has recently been introduced but not validated. Our objective was to evaluate clinical performance of 18F-fluoro-2-deoxyglucose (18F-FDG) PET/MRI in patients with head and neck cancer.

Methods

This retrospective study was conducted between January 2013 and February 2013. Ten patients (eight men, two women; mean age, 61.4 ± 13.4 years) with histologically proven head and neck tumors were enrolled. Whole-body PET/MRI and regional positron emission tomography (PET) with dedicated MRI were sequentially obtained. Maximum standardized uptake value (SUVmax), SUVmean, metabolic tumor volume, total lesion glycolysis and contrast enhancement were analyzed. A total of ten whole-body positron emission tomography (PET), ten regional positron emission tomography (PET), ten dedicated MRI and ten regional PET/gadolinium-enhanced T1-weighted (Gd)-MRI images were analyzed for initial staging. Two nuclear medicine physicians analyzed positron emission tomography (PET) and PET/MRI with a consensus. One radiologist analyzed dedicated MRI. The primary lesions and number of metastatic lymph nodes analyzed from each image were compared.

Results

Eight patients were diagnosed with head and neck cancer (one tongue cancer, four tonsillar cancers, one nasopharyngeal cancer and two hypopharyngeal cancers) by histological diagnosis. Two benign tumors (pleomorphic adenoma and Warthin tumor) were diagnosed with surgical operation. Whole-body positron emission tomography (PET) and regional positron emission tomography (PET) attenuated by MRI showed good image quality for the lesion detection. Whole-body positron emission tomography (PET) and regional positron emission tomography (PET) detected ten primary sites and compensated for a missed lesion on dedicated MRI. A discordant number of suspicious lymph node metastases was noted according to the different images; 22, 16, 39 and 40 in the whole-body positron emission tomography (PET) only, dedicated MR, regional positron emission tomography (PET) only and regional PET/Gd-MRI, respectively. There was no distant metastasis based on analysis of whole-body positron emission tomography (PET) and whole-body PET/Dixon-volume interpolated breathhold examination (VIBE) MRI. Regional PET/Gd-MRI combined with whole-body PET/MRI modified staging in three patients. Lesions of primary tumor and suspicious metastasis were well detected on both value of SUVmax and visual analysis. The regional PET/Gd-MRI combined with whole-body PET/MRI showed convenient clinical staging performance compared with positron emission tomography (PET) and MRI alone.

Conclusion

In this preliminary study, PET attenuated by MRI showed good image quality to detect lesions. And whole-body PET/MRI as a single modality was feasible for staging in a clinical setting. Whole-body positron emission tomography (PET), regional positron emission tomography (PET), dedicated MRI and regional PET/Gd-MRI showed discordant results in lesion detection. These discordant results might be synergistic effect for accurate staging.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号