首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

Diffusion weighted magnetic resonance imaging (DWI) and dynamic contrast-enhanced (DCE) MRI have been considered useful for pathological staging and histological grading in bladder cancer. To our knowledge, no study has combined the two imaging modalities together to assess aggressiveness of bladder cancer.

Objective

To assess the clinical aggressiveness of bladder cancer with DCE MRI and DWI at 3.0 T.

Materials and methods

A total of 59 patients with 69 pathologically confirmed tumor lesions were included in this study. All patients underwent MR examination at 3.0 T basing on DWI and DCE imaging. Tumor staging and histological grade were evaluated. The aggressiveness of bladder cancer was classified as low-, intermediate-, or high-aggressiveness according to its pathological phenotype. Apparent diffusion coefficient (ADC) value and semi-quantitative parameters (wash-in rate and wash-out rate) were determined. The correlation between clinical aggressiveness and ADC value, wash-in rate and wash-out rate were analyzed. In addition, the diagnostic accuracy of the diffusion and semi-quantitative parameters were estimated using receiver operating characteristic curve (ROC).

Results

Aggressiveness of bladder cancer is negatively correlated with ADC value (r = −0.705, p < 0.0001) and wash-out rate (r = −0.719, p < 0.0001). The tumor ADC value is positively correlated with wash-out rate (r = 0.555, p < 0.0001). The diagnostic specificity and accuracy using tumor ADC value and wash-out for the tumor with size <24 mm were better than that tumors with size ≥24 mm. The sensitivity, specificity and accuracy of ADC and wash-out rate in combination in diagnosis of bladder cancer aggressiveness were 96.7%, 94.9% and 95.7%, respectively. ROC curve revealed the diagnostic performance of aggressiveness of bladder cancer using ADC value and wash-out rate were 0.928 (cut-off value: 0.905 × 10−3 mm2/s) and 0.891 (cut-off value: 0.685 min−1), respectively.

Conclusion

ADC and wash-out rate derived from DWI and DCE-MRI at 3.0 T have good potential to assess the aggressiveness of bladder cancer and the accuracy was greater for ADC than for semi-quantitative parameters.  相似文献   

2.

Objective

To compare morphologically normal appearing cartilage in two age groups with delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) and correlate magnetic resonance imaging (MRI) findings with histology.

Materials and methods

Twenty femoral head specimens collected from ten lambs (group I) and ten young adult sheep (group II) underwent dGEMRIC and histological assessment. A region of 2 cm2 with morphologically normal-appearing cartilage was marked with a surgical suture for subsequent matching of MRI and histological sections. The MRI protocol included a three-dimensional (3D) double-echo steady-state sequence for morphological cartilage assessment, a B1 pre-scan with various flip angles for B1 field heterogeneity correction, and 3D volumetric interpolated breathhold examination for T1Gd mapping (dGEMRIC). Histological analysis was performed according to the Mankin scoring system.

Results

A total of 303 regions of interest (ROI; 101 MRI reformats matching 101 histological sections) was assessed. Twenty-six ROIs were excluded owing to morphologically apparent cartilage damage or insufficient MR image quality. Therefore, 277 ROIs were analyzed. Histological analyses revealed distinct degenerative changes in various cartilage samples of group II (young adult sheep). Corresponding T1Gd values were significantly lower in the group of sheep (mean T1Gd?=?540.4 ms) compared with the group of lambs (mean T1Gd?=?623.6 ms; p?<?0.001).

Conclusions

Although morphologically normal, distinct cartilage degeneration may be present in young adult sheep cartilage. dGEMRIC can reveal these changes and may be a tool for the assessment of early cartilage degeneration.  相似文献   

3.

Objective

To determine the application of advanced coronary computed tomography angiography (CCTA) plaque analysis for predicting invasive fractional flow reserve (FFR) in intermediate coronary lesions.

Methods

Sixty-one patients with 71 single intermediate coronary lesions (≥50–80% stenosis) on CCTA prospectively underwent coronary angiography and FFR. Advanced anatomical and morphometric plaque analysis was performed based on CCTA data set to determine optimal criteria for significant flow impairment. A significant stenosis was defined as FFR ≤ 0.80.

Results

FFR averaged 0.85 ± 0.09, and 19 lesions (27%) were functionally significant. FFR correlated with minimum lumen area (MLA) (r = 0.456, p < 0.001), minimum lumen diameter (MLD) (r = 0.326, p = 0.006), reference lumen diameter (RLD) (r = 0.245, p = 0.039), plaque burden (r = −0.313, p = 0.008), lumen area stenosis (r = −0.305, p = 0.01), lesion length (r = −0.692, p < 0.001), and plaque volume (r = −0.668, p < 0.001). There was no relationship between FFR and CCTA morphometric plaque parameters. By multivariate analysis the independent predictors of FFR were lesion length (beta = −0.581, p < 0.001), MLA (beta = 0.360, p = 0.041), and RLD (beta = −0.255, p = 0.036). The optimal cutoffs for lesion length, MLA, MLD, RLD, and lumen area stenosis were >18.5 mm, ≤3.0 mm2, ≤2.1 mm, ≤3.2 mm, and >69%, respectively (max. sensitivity: 100% for MLA, max. specificity: 79% for lumen area stenosis).

Conclusions

CCTA predictors for FFR support the mathematical relationship between stenosis pressure drop and coronary flow. CCTA could prove to be a useful rule-out test for significant hemodynamic effects of intermediate coronary stenoses.  相似文献   

4.

Objective

To evaluate change over time of clinical scores, morphological MRI of cartilage appearance and quantitative T2 values after implantation with BioCart™II, a second generation matrix-assisted implantation system.

Methods

Thirty-one patients were recruited 6–49 months post surgery for cartilage defect in the femoral condyle. Subjects underwent MRI (morphological and T2-mapping sequences) and completed the International Knee Documentation Committee (IKDC) questionnaire. MRI scans were scored using the MR Observation of Cartilage Repair Tissue (MOCART) system and cartilage T2-mapping values were registered.Analysis included correlation of IKDC scores, MOCART and T2 evaluation with each other, with implant age and with previous surgical intervention history.

Results

IKDC score significantly correlated with MOCART score (r = −0.39, p = 0.031), inversely correlated with previous interventions (r = −0.39, p = 0.034) and was significantly higher in patients with longer follow-up time (p = 0.0028).MOCART score was slight, but not significantly higher in patients with longer term implants (p = 0.199).T2 values were significantly lower in patients with longer duration implants (p < 0.001). This trend was repeated in patients with previous interventions, although to a lesser extent.

Conclusions

Significant improvement with time from BioCart™II implantation can be expected by IKDC scoring and MRI T2-mapping values. Patients with previous knee operations can also benefit from this procedure.  相似文献   

5.

Objective

To evaluate dynamic volume perfusion CT (dVPCT) tumor baseline characteristics of three different subtypes of lung cancer in untreated patients.

Materials and methods

173 consecutive patients (131 men, 42 women; mean age 61 ± 10 years) with newly diagnosed lung cancer underwent dVPCT prior to biopsy. Tumor permeability, blood flow (BF), blood volume (BV) and mean transit time (MTT) were quantitatively assessed as well as tumor diameter and volume. Tumor subtypes were histologically determined and compared concerning their dVPCT results. dVPCT results were correlated to tumor diameter and volume.

Results

Histology revealed adenocarcinoma in 88, squamous cell carcinoma in 54 and small cell lung cancer (SCLC) in 31 patients. Tumor permeability was significantly differing between adenocarcinoma, squamous cell carcinoma and SCLC (all p < 0.05). Tumor BF and BV were higher in adenocarcinomathan in SCLC (p = 0.001 and p = 0.0002 respectively). BV was also higher in squamous cell carcinoma compared to SCLC (p = 0.01). MTT was not differing between tumor subtypes. Regarding all tumors, tumor diameter did not correlate with any of the dVPCT parameters, whereas tumor volume was negatively associated with permeability, BF and BV (r = −0.22, −0.24, −0.24, all p < 0.05). In squamous cell carcinoma, tumor diameter und volume correlated with BV (r = 0.53 and r = −0.40, all p < 0.05). In SCLC, tumor diameter und volume correlated with MTT (r = 0.46 and r = 0.39, all p < 0.05). In adenocarcinoma, no association between morphological and functional tumor characteristics was observed.

Conclusions

dVPCT parameters are only partially related to tumor diameter and volume and are significantly differing between lung cancer subtypes.  相似文献   

6.

Objective

We developed a semi-automated tool to quantify emphysema from thoracic X-ray multi-detector (64-slice) computed tomography (CT) for training purposes and multi-reader studies.

Materials and Methods

Thoracic X-ray CT was acquired in 93 ex-smokers, who were evaluated by six trainees with little or no expertise (trainees) and a single experienced thoracic radiologist (expert). A graphic user interface (GUI) was developed for emphysema quantification based on the percentile of lung where a score of 0 = no abnormalities, 1 = 1–25%, 2 = 26–50%, 3 = 51–75% and 4 = 76–100% for each lung side/slice. Trainees blinded to subject characteristics scored randomized images twice; accuracy was determined by comparison to expert scores, density histogram 15th percentile (HU15), relative area at −950 HU (RA950), low attenuation clusters at −950 HU (LAC950), −856 HU (LAC856) and the diffusing capacity for carbon monoxide (DLCO%pred). Intra- and inter-observer reproducibility was evaluated using coefficients-of-variation (COV), intra-class (ICC) and Pearson correlations.

Results

Trainee–expert correlations were significant (r = 0.85–0.97, p < 0.0001) and a significant trainee bias (0.15 ± 0.22) was observed. Emphysema score was correlated with RA950 (r = 0.88, p < 0.0001), HU15 (r = −0.77, p < 0.0001), LAC950 (r = 0.76, p < 0.0001), LAC856 (r = 0.74, p = 0.0001) and DLCO%pred (r = −0.71, p < 0.0001). Intra-observer reproducibility (COV = 4–27%; ICC = 0.75–0.94) was moderate to high for trainees; intra- and inter-observer COV were negatively and non-linearly correlated with emphysema score.

Conclusion

We developed a GUI for rapid and interactive emphysema scoring that allows for comparison of multiple readers with clinical and radiological standards.  相似文献   

7.

Objectives

To investigate whether cardiac computed tomography (CCT) can determine left ventricular (LV) radial, circumferential and longitudinal myocardial deformation in comparison to two-dimensional echocardiography in patients with congestive heart failure.

Background

Echocardiography allows for accurate assessment of strain with high temporal resolution. A reduced strain is associated with a poor prognosis in cardiomyopathies. However, strain imaging is limited in patients with poor echogenic windows, so that, in selected cases, tomographic imaging techniques may be preferable for the evaluation of myocardial deformation.

Methods

Consecutive patients (n = 27) with congestive heart failure who underwent a clinically indicated ECG-gated contrast-enhanced 64-slice dual-source CCT for the evaluation of the cardiac veins prior to cardiac resynchronization therapy (CRT) were included. All patients underwent additional echocardiography. LV radial, circumferential and longitudinal strain and strain rates were analyzed in identical midventricular short axis, 4-, 2- and 3-chamber views for both modalities using the same prototype software algorithm (feature tracking). Time for analysis was assessed for both modalities.

Results

Close correlations were observed for both techniques regarding global strain (r = 0.93, r = 0.87 and r = 0.84 for radial, circumferential and longitudinal strain, respectively, p < 0.001 for all). Similar trends were observed for regional radial, longitudinal and circumferential strain (r = 0.88, r = 0.84 and r = 0.94, respectively, p < 0.001 for all). The number of non-diagnostic myocardial segments was significantly higher with echocardiography than with CCT (9.6% versus 1.9%, p < 0.001). In addition, the required time for complete quantitative strain analysis was significantly shorter for CCT compared to echocardiography (877 ± 119 s per patient versus 1105 ± 258 s per patient, p < 0.001).

Conclusion

Quantitative assessment of LV strain is feasible using CCT. This technique may represent a valuable alternative for the assessment of myocardial deformation in selected patients with poor echogenic windows and general contraindications for magnetic resonance imaging.  相似文献   

8.

Background

Treatment with bevacizumab is associated with substantial radiologic response in patients with glioblastoma (GB). However, following this initial response, changes in T2-weighted MRI signal may develop, suggesting an infiltrative pattern of tumor progression. The aim of this study was to differentiate between vasogenic-edema versus tumor-infiltrative area in GB patients.

Methods and materials

Fourteen patients with GB were longitudinally scanned, before and during intravenous bevacizumab therapy (5/10 mg/kg every 2-weeks). A total of 40 MR scans including conventional, diffusion, dynamic susceptibility contrast, dynamic contrast enhancement imaging, and MR-spectroscopy (MRS) were analyzed. Classification of non-enhancing fluid-attenuation-inversion-recovery (FLAIR) area was performed based on mean diffusivity, cerebral blood volume and flow maps, and further characterized using multiple MRI parameters.

Results

The non-enhancing FLAIR lesion area was classified into: vasogenic-edema, characterized by reduced perfusion and increased FLAIR values; or tumor-infiltrative area, characterized by increased perfusion. Tumor-infiltrative area demonstrated a higher malignant pattern on MRS compared to areas of vasogenic-edema. Substantial reductions of the enhanced T1-weighted (58 ± 10%) and hyperintense FLAIR (53 ± 9%) lesion volumes were detected mainly during the first weeks of therapy, with a shift to an infiltrative pattern of tumor progression thereafter, as detected by an increase in tumor-infiltrative area in the majority of patients, which correlated with progression-free survival (week 8: r = −0.86, p = 0.003, week 16: r = −0.99, p = 0.001).

Conclusion

Characterization of non-enhancing hyperintense FLAIR lesion area in GB patients can provide an MR-based biomarker, indicating a shift to an infiltrative progression pattern, and may improve therapy response assessment in patients following bevacizumab therapy.  相似文献   

9.

Objective

The aim of this study was to assess the glycosaminoglycan (GAG) content in hip joint cartilage in mature hips with a history of slipped capital femoral epiphysis (SCFE) using delayed gadolinium-enhanced MRI of cartilage (dGEMRIC).

Methods

28 young-adult subjects (32 hips) with a mean age of 23.8 ± 4.0 years (range: 18.1-30.5 years) who were treated for mild or moderate SCFE in adolescence were included into the study. Hip function and clinical symptoms were evaluated with the Harris hip score (HHS) system at the time of MRI. Plain radiographic evaluation included Tonnis grading, measurement of the minimal joint space width (JSW) and alpha-angle measurement. The alpha-angle values were used to classify three sub-groups: group 1 = subjects with normal femoral head-neck offset (alpha-angle <50°), group 2 = subjects with mild offset decrease (alpha-angle 50°-60°), and group 3 = subjects with severe offset decrease (alpha-angle >60°).

Results

There was statistically significant difference noted for the T1Gd values, lateral and central, between group 1 and group 3 (p-values = 0.038 and 0.041). The T1Gd values measured within the lateral portion were slightly lower compared with the T1Gd values measured within the central portion that was at a statistically significance level (p-value <0.001). HHS, Tonnis grades and JSW revealed no statistically significant difference.

Conclusion

By using dGEMRIC in the mid-term follow-up of SCFE we were able to reveal degenerative changes even in the absence of joint space narrowing that seem to be related to the degree of offset pathology. The dGEMRIC technique may be a potential diagnostic modality in the follow-up evaluation of SCFE.  相似文献   

10.

Objective

To investigate the usefulness of apparent diffusion coefficient (ADC) values in predicting true Gleason scores from radical prostatectomy specimen (tGS), compared with systematic transrectal ultrasound (TRUS)-guided biopsy GS (bGS).

Materials and methods

One hundred and five patients with biopsy-proven prostate cancer underwent preoperative DWI (b-values of 0, 1000, and 2000 s/mm2) of 3-T MRI. The mean and minimum ADCs of visible tumors were calculated for either of a pair of b-values: 0 and 1000 s/mm2 (ADC1000), or 0 and 2000 s/mm2 (ADC2000), and relationships between the four ADC parameters and tGS evaluated for the peripheral zone (PZ) and transition zone (TZ). For multiple tumors, the dominant tumor's GS and ADCs were estimated for cancer aggressiveness assessment by computing ROC curves.

Results

Significant negative correlations were observed between tGS and mean ADC1000, mean ADC2000, minimum ADC1000, and minimum ADC2000 (r = −0.41, −0.39, −0.39, and −0.37, respectively) of 100 visible PZ tumors and 66 visible TZ tumors (r = −0.40, −0.42, −0.29, and −0.21, respectively). For distinguishing high-grade from low/intermediate-grade PZ lesions, the areas under the curve (AUCs) of mean ADC1000 (0.751), mean ADC2000 (0.710), minimum ADC1000 (0.768), and minimum ADC2000 (0.752) were similar to that of the highest bGS (0.708) (p = 0.61, p = 0.98, p = 0.47, and p = 0.60, respectively). For distinguishing high-grade from low/intermediate-grade TZ lesions, AUCs of mean ADC1000 (0.779), and mean ADC2000 (0.811) were similar to that of the highest bGS (0.805) (p = 0.83 and p = 0.97).

Conclusion

Tumor ADCs obtained with high b-values could predict prostate cancer aggressiveness as effectively as systematic TRUS-guided biopsy.  相似文献   

11.

Background

Radiographic joint space width (JSW) is considered the reference standard for demonstrating structural therapeutic benefits in knee osteoarthritis. Our objective was to determine the proportion by which 3D (regional) meniscus and cartilage measures explain between-knee differences of JSW in the fixed flexion radiographs.

Methods

Segmentation of the medial meniscus and tibial and femoral cartilage was performed in double echo steady state (DESS) images. Quantitative measures of meniscus size and position, femorotibial cartilage thickness, and radiographic JSW (minimum, and fixed locations) were compared between both knees of 60 participants of the Osteoarthritis Initiative, with strictly unilateral medial joint space narrowing (JSN). Statistical analyses (between-knee, within-person comparison) were performed using regression analysis.

Results

A strong relationship with side-differences in minimum and a central fixed location JSW was observed for percent tibial plateau coverage by the meniscus (r = .59 and .47; p < .01) and central femoral cartilage thickness (r = .69 and .75; p < .01); other meniscus and cartilage measures displayed lower coefficients. The correlation of central femoral cartilage thickness with JSW (but not that of meniscus measures) was greater (r = .78 and .85; p < .01) when excluding knees with non-optimal alignment between the tibia and X-ray beam.

Conclusion

3D measures of meniscus and cartilage provide significant, independent information in explaining side-differences in radiographic JSW in fixed flexion radiographs. Tibial coverage by the meniscus and central femoral cartilage explained two thirds of the variability in minimum and fixed location JSW. JSW provides a better representation of (central) femorotibial cartilage thickness, when optimal positioning of the fixed flexion radiographs is achieved.  相似文献   

12.

Aim

To determine when preoperative breast MRI will not be more informative than available breast imaging and can be omitted in patients eligible for breast conserving therapy (BCT).

Methods

We performed an MRI in 685 consecutive patients with 692 invasive breast tumors and eligible for BCT based on conventional imaging and clinical examination. We explored associations between patient, tumor, and conventional imaging characteristics and similarity with MRI findings. Receiver operating characteristic (ROC) analysis was employed to compute the area under the curve (AUC).

Results

MRI and conventional breast imaging were similar in 585 of the 692 tumors (85%). At univariate analysis, age (p < 0.001), negative preoperative lymph node status (p = 0.011), comparable tumor diameter at mammography and at ultrasound (p = 0.001), negative HER2 status (p = 0.044), and absence of invasive lobular cancer (p = 0.005) were significantly associated with this similarity. At multivariate analysis, these factors, except HER2 status, retained significant associations. The AUC was 0.68.

Conclusions

It is feasible to identify a subgroup of patients prior to preoperative breast MRI, who will most likely show similar results on conventional imaging as on MRI. These findings enable formulation of a practical consensus guideline to determine in which patients a preoperative breast MRI can be omitted.  相似文献   

13.

Background

Magnetic resonance imaging (MRI) has been proposed for qualitative categorization of intraluminal thrombus morphology. We aimed to correlate the qualitative MRI categorization previously described to quantitative measurements of signal intensity and to compare morphological characteristics of intraluminal thrombus specimens to the appearance on magnetic resonance imaging.

Methods

Thirty-four patients undergoing open surgery for abdominal aortic aneurysm had a preoperative MRI obtained with a 1.5 T magnet. Qualitative categorization was performed (blinded and in consensus) and correlated to intraluminal thrombus to muscle signal-intensity ratios. Morphology of intraluminal thrombus specimens collected during surgery were compared to the magnetic resonance imaging categories and specimen weight was correlated to thrombus volume measured on preoperative computer tomography angiography.

Results

Blinded MRI categorization resulted in agreement in 22 out of 34 intraluminal thrombi (Kappa value 0.3, p = 0.006). Medians (p = 0.004) and distribution (p = 0.002) of signal-intensity ratios varied significantly across the three MRI categories obtained by consensus. Heterogeneous and homogenous specimen appearance corresponded to similar appearances on MRI in 78% and 55% respectively, resulting in an overall Kappa = 0.4 (p = 0.04). Intraluminal thrombus volume and weight correlated well (rs 0.831, p < 0.001) with a mean difference of 60 g (95% CI 38–80 g), without proportional bias.

Conclusion

Qualitative evaluation of intraluminal thrombus morphology based on MRI can be quantified by measuring signal-intensity ratios. Concurrently a fair agreement to blinded qualitative evaluation of thrombus specimens can be obtained. However, the evaluation is impaired by loss of a large proportion of thrombus during sampling.  相似文献   

14.

Introduction

Aim was to compare absolute myocardial perfusion using cardiac magnetic resonance imaging (CMRI) based on Tikhonov's procedure of deconvolution and rubidium-82 positron emission tomography (Rb-82 PET).

Materials and methods

Fourteen patients with coronary artery stenosis underwent rest and adenosine stress imaging by 1.5-Tesla MR Scanner and a mCT/PET 64-slice Scanner. CMRI were analyzed based on Tikhonov's procedure of deconvolution without specifying an explicit compartment model using our own software. PET images were analyzed using standard clinical software. CMRI and PET data was compared with Spearman's rho and Bland–Altman analysis.

Results

CMRI results were strongly and significantly correlated with PET results for the absolute global myocardial perfusion differences (r = 0.805, p = 0.001) and for global myocardial perfusion reserve (MPR) (r = 0.886, p < 0.001). At vessel territorial level, CMRI results were also significantly correlated with absolute PET myocardial perfusion differences (r = 0.737, p < 0.001) and MPR (r = 0.818, p < 0.001). Each vessel territory had similar strong correlation for absolute myocardial perfusion differences (right coronary artery (RCA): r = 0.787, p = 0.001; left anterior descending artery (LAD): r = 0.796, p = 0.001; left circumflex artery (LCX): r = 0.880, p < 0.001) and for MPR (RCA: r = 0.895, p < 0.001; LAD: r = 0.886, p < 0.001; LCX: r = 0.886, p < 0.001).

Conclusion

On a global and vessel territorial basis, CMRI-measured absolute myocardial perfusion differences and MPR were strongly and significantly correlated with the Rb-82 PET findings.  相似文献   

15.

Introduction

The aim of this study is to investigate if alterations of intra- and prelesionary motility in inflamed small-bowel segments correlate with length, wall-thickness and prelesionary dilatation of inflammatory small bowel lesions in patients suffering from Crohn's disease assessed with MRI.

Methods and materials

This retrospective IRB approved study included 25 patients (12 males, 18–77y) with inflammatory lesions examined using (MRE) magnetic resonance imaging enterography. Cine MRE was performed using a coronal 2D steady-state free precession sequence (TR 2.9, TE 1.25) on a 1.5T MRI scanner. Small bowel motility was examined using a dedicated MR-motility assessment software (Motasso, Vers. 1.0, Sohard AG, Bern, Switzerland). Motility patterns (contraction frequency, relative occlusion rate and mean diameter) were assessed in correlation to wall thickness, length and prelesionary dilatation of the lesions. Statistical analysis was performed by calculation of the Pearson's-Correlation coefficient.

Results

The length of the inflammatory segments, the wall thickening and prelesionary dilatation did not correlate with the frequency of the contractions (r = 0.17, p = 0.477; r = 0.316, p = 0.123; r = 0.161, p = 0.441) or the impairment of luminal occlusion (r = 0.274, p = 0.184; r = 0.199, p = .0339; r = 0.015, p = 0.945) and only the prelesionary dilatation (r = 0.410, p = 0.042) correlated to the mean luminal diameter of the segment.

Conclusion

The degree of motility impairment within inflammatory small bowel lesions does not significantly correlate with the extent of the lesion but with the motility measured in prelesionary, non-affected segments, suggesting an interdependent functional aspect of inflammation even in morphologically non-affected small bowel segments.  相似文献   

16.

Objective

To determine the change in apparent diffusion coefficient (ADC) of uterine fibroids following uterine fibroid embolisation (UFE), and if the ADC change correlates with either volume loss or degree of contrast enhancement post-UFE.

Materials and methods

This study was approved by our institutional review board with waiver of consent. The pelvic MRI examinations, including diffusion-weighted MRI (DWI) using 4 b-values, of 50 consecutive patients prior to and 6 months post-UFE were analyzed. The volume, ADC and amount of enhancement were calculated for each fibroid both pre- and post-UFE. The percent residual enhancement for each fibroid was categorized as either: no (0–1%) residual enhancement or residual (>1%) enhancement. Statistical analysis compared ADC, enhancement and volume for each fibroid pre- and post-UFE using paired t-tests and Pearson correlation coefficients.

Results

The mean ADC of all (n = 88) fibroids pre-UFE was 1.30 ± 0.20 × 10−3 mm2/s, and increased to 1.68 ± 0.24 × 10−3 mm2/s post-UFE (p < 0.0001). Lower pre-UFE ADC correlated with greater ADC change post-UFE (r = −0.50; p < 0.0001). There was no correlation between ADC change and volume change post-UFE (r = 0.07; p = 0.59). However, fibroids with no residual enhancement post-UFE had larger ADC change than those with residual enhancement (p = 0.003).

Conclusion

The ADC of fibroids rises post-UFE. ADC change post-UFE is associated with the degree of loss of enhancement and may therefore be valuable in predicting response to treatment in pre-procedural counseling.  相似文献   

17.

Objective

The aim of this study was to quantitatively evaluate the relationship between short echo time pulmonary 1H magnetic resonance imaging (MRI) signal intensity (SI) and 3He MRI apparent diffusion coefficients (ADC), high-resolution computed tomography (CT) measurements of emphysema, and pulmonary function measurements.

Materials and methods

Nine healthy never-smokers and 11 COPD subjects underwent same-day plethysmography, spirometry, short echo time ((TE) = 1.2 ms) 1H and diffusion-weighted hyperpolarized 3He MRI (b = 1.6 s/cm2) at 3.0 T. In addition, for COPD subjects only, CT densitometry was also performed.

Results

Mean 1H SI was significantly greater for never-smokers (12.1 ± 1.1 arbitrary units (AU)) compared to COPD subjects (10.9 ± 1.3 AU, p = 0.04). The 1H SI AP-gradient was also significantly greater for never-smokers (0.40 AU/cm, R2 = 0.94) compared to COPD subjects (0.29 AU/cm, R2 = 0.968, p = 0.05). There was a significant correlation between 1H SI and 3He ADC (r = −0.58, p = 0.008) and significant correlations between 1H MR SI and CT measurements of emphysema (RA950, r = −0.69, p = 0.02 and HU15, r = 0.66, p = 0.03).

Conclusions

The significant and moderately strong relationship between 1H SI and 3He ADC, as well as between 1H SI and CT measurements of emphysema suggests that these imaging methods and measurements may be quantifying similar tissue changes in COPD and that pulmonary 1H SI may be used to monitor emphysema as a complement to CT and noble gas MRI.  相似文献   

18.

Objectives

To systematically review the literature on dating subdural hematomas (SDHs) on CT and MRI scans.

Methods

We performed a systematic review in MEDLINE, EMBASE and Cochrane to search for articles that described the appearance of SDHs on CT or MRI in relation to time between trauma and scanning. Two researchers independently screened the articles, assessed methodological quality and performed data extraction. Medians with interquartile ranges were calculated. Differences were tested with a Mann–Whitney U or Kruskal–Wallis H test.

Results

We included 22 studies describing 973 SDHs on CT and 4 studies describing 83 SDHs on MRI. Data from 17 studies (413 SDHs) could be pooled. There were significant differences between time intervals for the different densities on CT (p < 0.001). Time interval differed significantly between children and adults for iso- and hypodensity (p = 0.000) and hyperdensity (p = 0.046). Time interval did not differ significantly between abused and non-abused children. On MRI, time intervals for different signal intensities on T1 and T2 did not differ significantly (p = 0.108 and p = 0.194, respectively).

Conclusions

Most time intervals of the different appearances of SDHs on CT and MRI are broad and overlapping. Therefore CT or MRI findings cannot be used to accurately date SDHs.  相似文献   

19.

Background

Tube current modulation in retrospective ECG gated cardiac computed tomography (CT) results in increased image noise and may reduce the accuracy of left ventricular (LV) ejection fraction (EF) and mass assessment.

Objective

To examine the effects of a novel CT phase-based noise reduction (NR) algorithm on LV EF and mass quantification as compared to cardiac magnetic resonance (CMR).

Methods

In 40 subjects, we compared the LV EF and mass between CT and CMR. In a subset of 24 subjects with tube current modulated CT, the effect of phase-based noise reduction strategies on contrast-to-noise ratio (CNR) and the assessment of LV EF and mass was compared to CMR.

Results

There was excellent correlation between CT and CMR for EF (r = 0.94) and mass (r = 0.97). As compared to CMR, the limits of agreement improved with increasing strength of NR strategy. There was a systematic underestimation of LV mass by CT compared to CMR with no NR (−10.3 ± 10.1 g) and low NR (−10.3 ± 12.5 g), but was attenuated with high NR (−0.5 ± 8.3 g). Studies without NR had lower CNR compared to low and high NR at both the ES phase and ED phase (all p < 0.01).

Conclusions

A high NR strategy on tube current modulated functional cardiac CT improves correlation of EF compared to CMR and reduces variability of EF and mass evaluation by increasing the CNR. In an effort to reduce radiation dose with tube current modulation, this strategy provides better image quality when LV function and mass quantification is needed.  相似文献   

20.

Purpose

To assess the clinical value of retrospective image fusion of neck MRI and 18F-fluorodeoxyglucose (18F-FDG) PET for locoregional extension and nodal staging of neck cancer.

Materials and methods

Thirty patients with carcinoma of the oral cavity or hypopharynx underwent PET/CT and contrast-enhanced neck MRI for initial staging before surgery including primary tumor resection and neck dissection. Diagnostic performance of PET/CT, MRI, and retrospective image fusion of PET and MRI (fused PET/MRI) for assessment of the extent of the primary tumor (T stage) and metastasis to regional lymph nodes (N stage) was evaluated.

Results

Accuracy for T status was 87% for fused PET/MRI and 90% for MRI, thus proving significantly superior to PET/CT, which had an accuracy of 67% (p = 0.041 and p = 0.023, respectively). Accuracy for N status was 77% for both fused PET/MRI and PET/CT, being superior to MRI, which had an accuracy of 63%, although the difference was not significant (p = 0.13). On a per-level basis, the sensitivity, specificity and accuracy for detection of nodal metastasis were 77%, 96% and 93% for both fused PET/MRI and PET/CT, compared with 49%, 99% and 91% for MRI, respectively. The differences for sensitivity (p = 0.0026) and accuracy (p = 0.041) were significant.

Conclusion

Fused PET/MRI combining the individual advantages of MRI and PET is a valuable technique for assessment of staging neck cancer.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号