首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A retrospective analysis of 52 patients with hip pain following total hip replacement was made. Each of them was evaluated by plain radiographs, technetium 99m pyrophosphate scans, arthrography with plain film subtraction technique, and culture of joint fluid. In 30 cases there was evidence of prosthetic loosening, and in 21 of these lymphangeal opacification during arthrography was seen. In 15 cases with lymphongeal opacification the diagnosis of prosthetic loosening was subsequently confirmed by prosthetic revision. In none of the 22 cases in which no evidence of prosthetic loosening was seen was there lymphatic opacification. It is concluded that lymphatic opacification during arthrography for pain following total hip prosthesis is a valuable ancillary sign of loosening.  相似文献   

2.
Arthroscintigraphic evaluation of the painful total hip prosthesis   总被引:1,自引:0,他引:1  
Arthroscintigraphy was performed in 19 patients with a painful total hip prosthesis by injecting both Tc-99m sulfur colloid and iodinated radiographic contrast material intra-articularly. Scintigraphic and radiographic results correlated exactly in 15 patients, with one false-negative scintigram, one false-positive scintigram, and one false-negative arthrogram. One patient was evaluated by scintigraphy alone. Although arthroscintigraphy is potentially more sensitive than conventional arthrography in the detection of femoral component loosening, acetabular component loosening cannot be evaluated by scintigraphy alone. A combination of scintigraphy and conventional arthrography appears to be the most accurate imaging method in the evaluation of hip prosthesis loosening.  相似文献   

3.
Radionuclide arthrography is becoming increasingly useful in the evaluation of femoral component loosening in patients with a painful total hip prosthesis. Additional potential advantages of radionuclide arthrography include detection of abnormal communications with the hip, such as bursae, abscess cavities, and fistulas. A case of cutaneous fistula communicating with the hip in a patient with loosening and infection of the femoral component of the total hip prosthesis that is clearly demonstrated by radionuclide arthrography is presented.  相似文献   

4.
The recent popularity of ingrowth or uncemented hip arthroplasties has presented problems in the radiographic diagnosis of loosening because there is no longer a cement interface in which lucencies may be seen. We evaluated a combination of positive contrast and nuclear arthrography to see whether these studies could accurately detect loosening of uncemented femoral components of hip prostheses. We performed routine contrast and nuclear arthrography in 21 patients with ingrowth total hip arthroplasties or bipolar endoprostheses. The results were surgically confirmed in 12 patients. The contrast arthrogram was true positive in 5 and false negative in 5. There were no false positives and 2 true negatives. The nuclear arthrogram was true positive in 7 patients, false negative in 3, and true negative in 2. Taken together, there was only 1 patient in whom both contrast and nuclear arthrography were false negative, and there were no false positives. Thus, when either contrast or nuclear arthrography is positive, the sensitivity of the combined procedures is 90%; when both studies are negative, the specificity is 100%. The combination of contrast and nuclear arthrography is an accurate method of determining loosening of the femoral component of an uncemented hip arthroplasty or bipolar endoprosthesis in the patient with postoperative hip pain.  相似文献   

5.
K-edge energy subtraction radiography is a method for detecting the presence of iodinated contrast material by subtracting two digital radiographs produced by X-ray beams with energies above and below the iodine K edge. We performed a feasibility study on the application of K-edge energy digital subtraction arthrography (KEDSA) to painful hip prostheses. During arthrography, loosening of the prosthesis is implied if contrast material is seen dissecting around the prosthesis, an often difficult detection task because of adjacent prosthesis metal or cement. In conventional arthrography a preliminary mask image is thus used from which films obtained after injection of iodinated contrast material are subtracted. Movement by the patient during this process may preclude subsequent subtraction. With KEDSA, since multiple image pairs may be obtained after the injection of contrast material, the problem of patient motion is virtually eliminated. A conventional X-ray tube operating between 55 and 65 kVp was alternately filtered by iodine and cerium filters to produce the KEDSA images. The apparatus was capable of producing a subtracted image within 3 sec. The technique was applied to phantoms and to six patients immediately after hip arthrography that had been positive for prosthesis loosening. Although of lower spatial resolution, the KEDSA images were, in all cases, positive for loosening in a pattern consistent with the conventional arthrographic images. KEDSA was shown to be successful in detecting extraarticular contrast material. During a single study, subtraction in various imaging planes as well as postexercise subtraction imaging can be accomplished-techniques not heretofore possible in routine subtraction arthrography.  相似文献   

6.
Twenty patients with 21 total joint replacements including 17 hips and 4 knees were studied by plain film radiography, radionuclide imaging, and subtraction arthrography to evaluate these procedures for assessing prosthetic complications. Surgery was performed in 14 patients and confirmed loosening of 8 femoral and 7 acetabular hip prosthesis components and 1 femoral and 4 tibial knee prosthesis components. Plain films suggested loosening of only 9 hip components and no knee components. In contrast, radionuclide imaging and subtraction arthrography were considerably more effective in demonstrating loosening as well as other causes of the painful total joint prosthesis.  相似文献   

7.
Radiological evaluation of painful total hip replacement   总被引:3,自引:0,他引:3  
Ninety-four cases of clinically failed, cemented, total hip prostheses requiring surgery were reviewed to determine the accuracy of preoperative plain radiography, culture of aspirated fluid, arthrography, and bone scanning. When radiopaque cement had been used to embed the prosthesis, plain radiography was highly accurate in detecting a loose femoral component, less so in detecting a loose acetabular component. Culture of aspirated fluid was accurate in diagnosing infection. A positive arthrogram identified loosening with good accuracy; however, a negative arthrogram did not reliably exclude loosening. 99mTc bone scans frequently differentiated loosening from loosening with infection. The suggested sequence of diagnostic tests is plain radiography followed by bone scanning. If the bone scan shows diffuse augmented uptake, culture of aspirated fluid followed by arthrography is indicated.  相似文献   

8.
Previous reports have stressed the value of hip arthrography primarily in determining the presence of loosening of the total hip prosthesis. Although loosening is a common complication and frequently associated with infection, other complications producing a painful hip prosthesis exist and are demonstrable by arthrography. Since the etiologies of these are as diversely different as the treatment, the hip arthrogram is advocated as an integral part of the diagnostic approach to the patient with a painful hip prosthesis in order to assess the specific complication and determine the therapeutic approach.  相似文献   

9.
The evaluation of a painful hip prosthesis for suspected loosening frequently requires a multi-modality approach. Radionuclide arthroscintigraphy is a valuable adjunct to contrast arthrography, demonstrating greater sensitivity than contrast arthrography in detecting loosening of the femoral component of the prosthesis. Despite its reliability in the evaluation of cemented hip prostheses, the value of arthroscintigraphy in patients with uncemented or porous-coated prostheses is undetermined. The case of a false-positive radionuclide arthroscintigram in a patient with an uncemented prosthesis is reported. The literature is briefly examined, and the potential implications regarding interpretation of arthroscintigraphy in patients with porous-coated prostheses are discussed.  相似文献   

10.
OBJECTIVE: To summarize and compare the diagnostic accuracy of contrast and subtraction arthrography in the assessment of aseptic loosening of total hip arthroplasties. DESIGN: This meta-analysis was performed using methods described by the Cochrane Methods Group on Systematic Reviews of Screening and Diagnostic Tests. We included original, English-language papers published between January 1975 to October 2004 that examined contrast-enhanced arthrography with or without subtraction for diagnosis of loosening of total hip prostheses. A qualitative and quantitative analysis was performed by two investigators. RESULTS: With regard to the acetabular component, pooled sensitivity and specificity for contrast arthrography was 70% (95% confidence interval, 52-84) and 74% (95% CI, 53-87), respectively. Subtraction arthrography had a significantly higher sensitivity of 89% (95% CI, 84-93) (p=0.01), with a similar specificity of 76% (95% CI, 68-82). For the femoral component, pooled sensitivity and specificity for contrast arthrography were 63% (95% CI, 53-72) and 78% (95% CI, 68-86). Pooled estimates for subtraction arthrography revealed a significantly higher sensitivity of 86% (95% CI, 74-93) (p=0.003). Specificity was 85% (95% CI, 77-91) and was similar to the data of contrast arthrography (p=0.23). CONCLUSION: Using the present data we found that the subtraction arthrography is a sensitive technique for detection of loosening of total hip prostheses, offering added value over contrast arthrography, especially for evaluation of the femoral component.  相似文献   

11.
Objective. The objective of this clinical study was to define the diagnostic value of plain radiography, digital subtraction arthrography and two-phase bone scintigraphy in patients with clinically loose or infected hip prostheses. Design. Digital subtraction arthrograms, scintigrams and plain radiographs of 70 consecutive patients who underwent revision hip arthroplasty were scored individually and in masked fashion for the presence or absence of features indicating loosening of femoral and/or acetabular components. The operative findings acted as the gold standard. Results. Digital subtraction arthrography was best (P<0.001) for predicting a loose acetabular component, while no significant additional predictive value was found for plain radiographs (P=0.24) and scintigraphy (P=0.27). Digital subtraction arthrography was also the most important modality for predicting a loose femoral component (P=0.001), while the plain radiograph was of significant (P=0.04) additional value and scintigraphy was of no additional value (P=0.13) on multivariate analysis. Conclusion. Digital subtraction arthrography gives the best results in the prediction of loosening of acetabular and femoral components. Plain radiographs give additional information on loosening of the femoral component, but scintigraphy offers no additional advantage.  相似文献   

12.
Arthrography is a useful method to prove the loosening of the cup after total hip replacement. Contrast medium seeping between the bone and acrylic is an unequivocal sign of loosening. False positive diagnoses are unknown. Because of the risk of infection, arthrography is only indicated, if plain films and push-pull-roentgenograms are not significant. Possible errors and complications are discussed.  相似文献   

13.
Nuclear medicine has proven to have a valuable role in the evaluation of osseous metallic implants, particularly with joint prostheses, but can assist with evaluation of other appliances as well. The nuclear arthrogram has become an invaluable adjunct to simultaneously performed radiographic contrast arthrography. This application has been best evaluated in what is one of the most common of orthopedic prosthesis problems, namely, loosening of total hip prostheses. Experience indicates that both sensitivity and specificity of loosening of the femoral component can be increased to over 90% through combined use of nuclear with radiographic contrast arthrography. Furthermore the combination of routine skeletal scintimaging with the nuclear arthrogram adds a significant dimension to precise localizing of the nuclear arthrographics agent In-111 chloride. Nuclear medicine also plays an important role in further evaluating the presence of infection associated with metallic implants with In-111 WBC preparations being superior to Ga-67 as the radiopharmaceutical tracer. Infection has been detected with a sensitivity of 73% and a specificity of 93% in our series using combined In-111 WBC and simultaneous skeletal imaging with conventional Tc-99m MDP. Acute infections are more readily identifiable than chronic in association with prostheses.  相似文献   

14.
The authors had first experiences of hip arthrography in prostheses loosening in 1967. Now they explain the results obtained in 51 cases, aknowledging the limits of such a method in a few cases, but generally accepting the value of it for correct therapeutic choices.  相似文献   

15.
Patients with problems following implantation of cemented total hip prostheses must be clinically examined. This examination is followed by a series of diagnostic imaging procedures. These include X-ray diagnosis, 3-phase 99mTc-MDP bone scans, scintigraphy for inflammation, and arthrography, performed singly or as sequential studies. X-ray findings and scintigraphic patterns arousing or confirming a suspicion of aseptic (mechanical) or septic (infectious) loosening of the prosthesis are evaluated and discussed.  相似文献   

16.
Twenty-one joints with stable (n = 9) or loose (n = 12) osteochondritis dissecans (OCD) lesions were examined in 15 subjects with plain radiography, three-phase bone scintigraphy, and magnetic resonance (MR) imaging. The lesion size and the thickness of the sclerotic margin as measured on plain radiographs were good parameters for predicting loosening. However, bone scintigraphy was more sensitive and specific in determining the mechanical stability of OCD lesions. MR imaging permitted direct visualization of loosening and fragment displacement; the latter permits differentiation of in situ loosening from a grossly unstable lesion. The noninvasive nature of bone scintigraphy and MR imaging makes them potentially preferable diagnostic modalities to arthrography for evaluating the mechanical status of OCD lesions.  相似文献   

17.
As total knee replacement becomes more successful due to advances in surgery and bioengineering, a greater number of patients will be offered this procedure as a viable alternative to arthrodesis. Radiologic consultation will be sought for evaluation of proper alignment as well as postoperative complications such as loosening, instability, dislocation, limitation of range of motion, fracture, and infection. This evaluation may be accomplished by plain films and arthrography. Radiographic aspects of these features are discussed and illustrated.  相似文献   

18.
Digital and manual subtraction images obtained during the arthrographic evaluation of 78 painful hip prostheses were reviewed retrospectively. Revision arthroplasty was performed in 53 of these cases, and the arthrographic and surgical findings were correlated. The digital and manual subtraction images were evaluated without knowledge of the surgical results using established criteria for component loosening. Digital subtraction arthrography of the femoral component demonstrated a 96% sensitivity and 100% specificity for the diagnosis of component loosening. Sensitivity and specificity for acetabular component loosening were 83% and 80%, respectively. Plain film subtraction of the femoral component demonstrated a 79% sensitivity and 100% specificity; the sensitivity and specificity for the acetabular component were 75% and 80%, respectively. The difference between detection of femoral component loosening on digital as opposed to manual subtraction images was statistically significant (P<0.05). This study demonstrates that digital subtraction improves the evaluation of femoral component loosening in painful hip prostheses.  相似文献   

19.
The radiology of total hip replacement (THR) and its complications is reviewed in conjunction with a long-term follow-up study on 402 patients with 501 prostheses. The indications, contraindications, biomechanics, and operative management of these patients is discussed. Clinical complications such as deep vein thrombosis, pulmonary embolism, and hemorrhage are mentioned. Postoperative infections including granulomatous pseudotumors, dislocations and fractures, true loosening of the prosthesis, and heterotopic bone formation (HBF) are discussed and illustrated. The importance of differentiating the lucent line from true loosening is stressed. Mechanical and other clinical complications which are largely ignored by radiologists are also discussed. The uses of arthrography and bone scanning are included.  相似文献   

20.
Radiophosphate evaluation of loose hip prostheses   总被引:1,自引:0,他引:1  
There were 23 patients who had revisions of their failed hip arthroplasties and a prior radiophosphate assessment of the joint components. In this selected group of patients the true positive incidence of abnormal scintigraphic findings for femoral component loosening was 19 out of 20 (95%) and the true negative incidence was two out of two by the criteria adopted. The true positive incidence of such findings, indicating acetabular component loosening, was seven out of seven, and the true negative was nine out of 10. Some of these patients also had contrast arthrography and the incidences of true positive and true negative findings for femoral component loosening were seven out of 15 (47%) and one out of one, respectively. Prediction of the status of the acetabulum was poorer using this technique with true positive and true negative incidences of four out of nine and two out of five, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号