首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Purpose

To assess the role of ultrasonography in detection, and categorization of breast lesions in patients with mammographically dense breasts with the use of the BI-RADS US lexicon.

Patients and methods

This study included 60 female patients (age range from 20 to 80 years, mean 38.3 ± 11.9) complaining of mastalgia, breast lump or nipple discharge with mammographically dense breast tissue. Breast ultrasound was performed to all patients with a 12-MHz linear-array transducer. Sonographic findings of the breast lesions were described and categorized according to the BI-RADS US assessment categories. Biopsy procedures were performed for the sonographically detected breast lesions with histopathological examination of the biopsied tissue.

Results

The main complaint was palpable breast mass encountered in 25 patients, 12 of mastalgia, 4 of nipple discharge, 12 patients were on screening and 7 on follow up. 36 patients were categorized as ACR 3 and 24 ACR 4 regarding the density of their breasts in mammography. Mammography revealed no abnormalities in 31 patients and abnormal in 29 patients, the commonest mammographic finding was breast mass, detected in 19 patients. Ultrasound detected breast lesions in 56 (93.3%) out of 60 patients. BI-RADS US category 2 was the most common category representing 36.7%. Ultrasonography had a diagnostic reliability for differentiating between benign and malignant breast lesions (p = 0.869) in mammographically dense breasts while mammography was diagnostically unreliable (p = 0.045).

Conclusion

Ultrasound is a mandatory adjunct to mammography in detection and characterization of breast lesions in mammographically dense breasts.  相似文献   

2.

Objective

To prospectively evaluate the diagnostic efficacy of conventional ultrasound (US), contrast-enhanced US (CEUS), the combined use of two modalities, and magnetic resonance imaging (MRI) in the differentiation of focal solid breast lesions.

Materials and methods

61 patients with BI-RADS category 3–5 breast lesions detected at conventional US underwent CEUS and MRI. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of conventional US, CEUS, combination of two modalities and MRI for discrimination between benign and malignant breast lesions.

Results

Tissue specimens of 61 breast lesions were obtained either from surgical resection (n = 46) or from needle biopsy (n = 15). Histopathologic diagnosis revealed 28 benign and 33 malignant lesions. The diagnostic performance of conventional US and CEUS in differentiating benign from malignant breast lesions showed no significant difference (P = 0.741). The combination of two modalities significantly improved the diagnostic accuracy compared with either conventional US or CEUS alone (P = 0.031 and P = 0.012, respectively). The area under the ROC curve (Az) value for the combined use of two modalities for discrimination between benign and malignant breast lesions was 0.94, and that for MRI was 0.91, whereas no statistical difference was found between them (P = 0.296).

Conclusion

The combined use of conventional US and CEUS has a better diagnostic performance than either method alone and displays good agreement with MRI in the differentiation capability for benign and malignant breast lesions.  相似文献   

3.

Objective

To evaluate whether the degree of background parenchymal enhancement affects the accuracy of tumor size estimation based on breast MRI.

Methods

Three hundred and twenty-two patients who had known breast cancer and underwent breast MRIs were recruited in our study. The total number of breast cancer cases was 339. All images were assessed retrospectively for the level of background parenchymal enhancement based on the BI-RADS criteria. Maximal lesion diameters were measured on the MRIs, and tumor types (mass vs. non-mass) were assessed. Tumor size differences between the MRI-based estimates and estimates based on pathological examinations were analyzed. The relationship between accuracy and tumor types and clinicopathologic features were also evaluated.

Results

The cases included minimal (47.5%), mild (28.9%), moderate (12.4%) and marked background parenchymal enhancement (11.2%).The tumors of patients with minimal or mild background parenchymal enhancement were more accurately estimated than those of patients with moderate or marked enhancement (72.1% vs. 56.8%; p = 0.003). The tumors of women with mass type lesions were significantly more accurately estimated than those of the women with non-mass type lesions (81.6% vs. 28.6%; p < 0.001). The tumor of women negative for HER2 was more accurately estimated than those of women positive for HER2 (72.2% vs. 51.6%; p = 0.047).

Conclusion

Moderate and marked background parenchymal enhancement is related to the inaccurate estimation of tumor size based on MRI. Non-mass type breast cancer and HER2-positive breast cancer are other factors that may cause inaccurate assessment of tumor size.  相似文献   

4.

Objective

To verify the capacity of targeted ultrasound (US) to identify additional lesions detected on breast magnetic resonance imaging (MRI), but occult to initial mammography, US and clinical examinations.

Methods

This prospective study included 68 additional relevant breast lesions identified on MRI of 49 patients. As an inclusion criterion, breast US and mammography were required and performed up to six months before MRI. These lesions were then subjected to targeted “second-look” US up to 2 weeks after MRI, performed by one or two radiologists with expertise on breast imaging. Lesions were evaluated according to the established Breast Imaging Report and Data System (BI-RADS) lexicon.

Results

Targeted US identified 46/68 (67.6%) lesions revealed by MRI. No significant associations were observed between US identification and the type of lesion, dimensions, morphological characteristics and enhancement pattern according to MRI findings. Targeted US identified 100% of BI-RADS category 5 lesions, 90% of category 4 lesions, and just over 50% of category 3 lesions (p < 0.05). There was significant agreement (< 0.001) between MRI and US BI-RADS classification for all three categories.

Conclusion

Targeted US can identify a large proportion of the lesions detected by breast MRI, especially those at high risk of malignancy, when performed by a professional with experience in both breast US and MRI.  相似文献   

5.

Objective

Evaluation of the diagnostic value of magnetic resonance mammography and comparison with conventional mammography and ultrasonography in cases of women with suspicious breast lesions.

Subjects and methods

Sixty-nine women (age range 39–68 years) with 78 focal breast lesions were examined with mammography, ultrasonography and dynamic magnetic resonance mammography. The lesions were classified according to the Breast Imaging Reporting and Data System (BI-RADS) lexicon of the American College of Radiology for each diagnostic method. Histological reports were available after biopsy or surgical excision of the lesions.

Results

Pathological examination confirmed that 53 lesions were malignant and 25 benign. Conventional mammography estimated a total of 59/78 lesions as malignant with 44 true positive lesions, ultrasonography estimated a total of 50/78 lesions as malignant with 44 true positive lesions and magnetic resonance mammography estimated a total of 66/78 lesions as malignant with 52 true positive lesions. Sensitivity and specificity of magnetic resonance mammography in the diagnosis of malignancy was 98.1% and 44%, of conventional mammography 83% and 40% and of ultrasonography 83% and 76%. Negative predictive value for magnetic resonance mammography was 91.7%, for ultrasonography 67.9% and for mammography 52.6% for malignancies.

Conclusion

Magnetic resonance mammography has the highest negative predictive value compared with mammography and ultrasound in cases of suspicious breast lesions. The combination of morphologic and enhancement criteria can improve the diagnostic capability of magnetic resonance mammography (MRM) in breast lesion characterization.  相似文献   

6.

Objective

To explore the significance of contrast-enhanced MRI (CE-MRI) and diffusion-weighted imaging (DWI) in evaluating the short-term response of high intensity focused ultrasound (HIFU) ablation for primary hepatic carcinoma (PHC).

Methods

Thirty-nine lesions in the livers of 27 patients were performed HIFU ablation. Conventional MRI sequences, CE-MRI and DWI were performed 1 week before HIFU and 1 week, 3 months after the therapy, respectively. The short-term responses of HIFU for all lesions were evaluated with MRI.

Results

28 of the 39 lesions (28/39, 71.8%) showed complete necrosis with no enhancement 1 week and 3 months after HIFU. The apparent diffusion coefficient (ADC) values 1 week and 3 months after HIFU were significantly higher than those 1 week before treatment (p < 0.05). The tumor recurrence was detected in 7 of the 39 lesions (7/39, 17.9%) which had no significant enhancement 1 week after HIFU. On the 3 months follow-up, focal nodules were found on the inner aspects of the treated areas. The ADC values had no significant difference between 1 week before and after treatment (p > 0.05), however, they were significantly higher 3 months after HIFU (p < 0.05). The tumor residuals were detected in 4 of the 39 lesions (4/39, 10.3%) showing enhancement 1 week after treatment and increased size 3 months after HIFU. The ADC values had no significant difference among 1 week before HIFU, 1 week and 3 months after treatment (p > 0.05).

Conclusion

CE-MRI and DWI can be employed to evaluate the short-term response of HIFU ablation for PHC and to guide the patient management.  相似文献   

7.

Objectives

Handheld breast ultrasound (HHUS) lacks standardization and reproducibility. The automated breast volume scanner (ABVS) could overcome this limitation. To analyze the interobserver reliability of ABVS and the agreement with HHUS, mammography and pathology is the aim of this study.

Methods

All 42 study participants (=84 breasts) received an ABVS examination in addition to the conventional breast diagnostic work-up. 25 breasts (30%) showed at least one lesion. The scans were interpreted by six breast diagnostic specialists blinded to results of breast imaging and medical history. 32 lesions received histological work-up: 20 cancers were detected. We used kappa statistics to interpret agreement between examiners and diagnostic instruments.

Results

On the basis of the Breast Imaging Reporting and Data System (BI-RADS) classification of the 84 breasts an agreement (defined as ≥4 of 6 examiners) was achieved in 63 cases (75%) (mk = 0.35) and even improved when dichotomizing the interpretation in benign (BI-RADS 1, 2) and suspicious (BI-RADS 4, 5) to 98% (mk = 0.52). Agreement of ABVS examination to HHUS, mammography and pathology was fair to substantial depending on the specific analysis.

Conclusions

The development of an ABVS seems to be a promising diagnostic method with a good interobserver reliability, as well as a comparable good test criteria as HHUS.  相似文献   

8.

Purpose

To provide a strategy for precise co-localization of lymph nodes on axillary lymph-node dissection (ALND) specimens both on pathology and MR.To identify nodal features suggestive of metastatic involvement on a node-to-node basis.

Materials and methods

National Institutional review-board approved this prospective study of 18 patients with breast cancer referred for ALND. Ex vivo T1 and inversion recovery (IR) T2 WI of ALND specimens tightly positioned within scaled plastic cranes was performed immediately after surgery. The correspondence of MR-based or pathologically based nodes location was assessed. The MR size and morphological presentation of metastatic and normal nodes were compared (Student's t-test or Mann–Whitney test). Quantitative variables were compared using Pearson coefficient.

Results

207 nodes were retrieved on pathology and 165 on MR. MR–pathological correlation of nodes location was high regarding MR-identified nodes (r = 0.755). An MR short axis threshold of 4 mm yielded the best predictive value for metastatic nodal involvement (Se = 78.6%; Sp = 62.3%). Irregular contours (Se = 35.7%; Sp = 96.7%), central nodal hyper-intensity on IR T2 WI (Se = 57.1%; Sp = 91.4%), and a cortical thickness above 3 mm (Se = 63.6%; Sp = 83.2%) were significantly associated with metastatic involvement.

Conclusion

Ex vivo MR allows node-to-node correlation with pathology. Morphological MR criteria can suggest metastatic involvement.  相似文献   

9.

Background

Several clinical studies showed that sonoelastography was useful for the differentiation of benign and malignant breast lesions. Contrast-enhanced MRI has emerged as a promising tool in the detection, diagnosis, and staging of breast cancer.

Aim of work

To study the role of sonoelastography versus dynamic MRI in evaluating BI-RADS III, IV breast masses and detect which modality is of better sensitivity and specificity trying to guide the patient either to follow-up the lesion or proceed to lesion excision.

Subjects and methods

The study included 50 Egyptian patients (age ranged from 32 to 58 years) who presented by breast masses and categorized as BI-RADS III, IV by mammography and ultrasound. Sonoelastography and dynamic MRI were done for all the patients.

Results

Differentiation between BI-RADS III and IV by US elastography had 84% sensitivity and 84% specificity and by MRI had 88% sensitivity and 80% specificity.

Conclusion

Regarding the sonoelastography, it is an easy and cheap modality. The elasticity score is an important parameter for lesion characterization. Combination of morphologic and dynamic MRI studies is very important for the breast lesion evaluation. MRI is more sensitive but less specific than sonoelastography. Finally if we find any suspicious character elicited by either sonoelastography or MRI (BI-RADS IV), lesion excision is recommended.  相似文献   

10.

Purpose

To detect axillary lymph node metastasis based on diffusion Weighted MR and apparent diffusion coefficient (ADC) in the known breast cancer cases.

Patient and methods

Forty-four patients were included in this study for preoperative MRI staging of the breast cancer and axillary lymph node assessment. The lymph node criteria (long/short-axis ratio, T2WI, DWI and ADC value) were included in the analysis. Images were obtained with diffusion sensitizing gradients of 0 and 750 mm2/s. The ADC was calculated.

Results

Thirty-two patients had metastatic axillary lymph nodes and 12 cases had no malignant LN involvement. There was no significant difference between both in S/L ratio, T2WISI (p < 0.140 & p = 0.079, respectively), while statistically significant difference between benign and malignant lymph nodes in both DWI and ADC mean values (p < 0.0001 & p < 0.007, respectively). The optimal ADC cut off value was ?.8 × 10−3 mm2/s for differentiation between benign and malignant lymph nodes with accuracy 96.7%, sensitivity 100%, specificity 87%, PPV 95.4% and NPV 100%.

Conclusion

Compared with lymph node size or routine magnetic resonance sequences, DWI and ADC are promising techniques for differentiating metastatic and non metastatic axillary lymph nodes in known breast cancer patients.  相似文献   

11.

Objective

To assess the final outcome of breast lesions detected during screening ultrasonography (US) and categorized by BI-RADS final assessment.

Materials and methods

During a 1-year period, 3817 consecutive asymptomatic women with negative findings at both clinical breast examinations and mammography underwent bilateral whole breast US and BI-RADS categories were provided for US-detected breast lesions. The reference standard was a combination of histology and US follow-up (≥12 months), and the final outcomes of 1192 US-detected lesions were analyzed.

Results

Of 904 category 2 lesions, 890 remained stable for 12–60 months. Biopsies of 14 lesions revealed no malignancies (NPV = 100%). Of 247 category 3 lesions, 232 remained stable for 12–60 months. Biopsies of 15 lesions revealed 2 malignancies, which were diagnosed within 6 months of the index examination and were node negative (NPV = 99.2%). Of 41 category 4 lesions, biopsies of 38 lesions revealed 5 malignancies (PPV = 12.2%), and 3 remained stable for 37–51 months. No US-detected lesion was classified as category 5.

Conclusion

The rates of malignancy for US-detected BI-RADS categories 2, 3, and 4 lesions were 0%, 0.8%, and 12.2%, respectively. The final assessment of US BI-RADS categorization showed it to be an appropriate predictor of malignancy for screening US-detected breast lesions.  相似文献   

12.

Objectives

To evaluate the accuracy of real-time MR navigated ultrasound (MRnav US) for tumor extent measurements in breast cancer and to investigate variables influencing the accuracy of MRnav US in comparison with US alone.

Methods

Fifty-three patients with 60 malignancies underwent preoperative breast MRI and US with or without MRI navigation. Maximum lesion sizes based on MRnav US and US alone were measured, and their relationship with the pathology was analyzed considering the differences in the clinicopathologic variables of the patients.

Results

Among 60 breast cancers, mean lesion size at initial breast US without MRI navigation and at MRI-navigated US was 19 mm and 24 mm, respectively, compared with 28 mm on the histopathology. Overall, the tumor size estimated with MRnav US was more strongly correlated with the histologic tumor size than with US alone. Accurate measurements by MRnav US were significantly more frequent in the lesions that were presented as a mass type on MRI. In addition, the accurate measurement of mass extent was improved with MRnav US in patients who had non-mass type lesions on MRI and who had undergone neoadjuvant systemic chemotherapy when compared with US alone.

Conclusion

MRnav US was more accurate for tumor extent estimation than US alone, and specific clinicopathologic variables can affect the accuracy of MRnav US.  相似文献   

13.

Objective

To asses the value of second-look ultrasound (US) for identifying BIRADS 3 (Breast Imaging Reporting Data System) mammary lesions detected by breast Magnetic Resonance imaging (MRI).

Materials and methods

From April 2008 to May 2009 330 breast MRI were performed of which 60 patients are classified as BIRADS 3. 84 lesions underwent second-look US and percutaneous vacuum biopsy Vacora system US-guided. Statistical analysis: lesions were stratified into two groups: visible on US (Group 1) and not visible on US (Group 2).The clinical impact of second-look US was studied in terms of negative predictive value (NPV).

Results

The positive predictive value (PPV) of category 3 BIRADS MRI was found to be 89%. Second look-US results detected lesions in 51% of the MRI enhancing lesions. The second look-US showed a NPV of 97%. The NPV of second look-US was significantly greater than the NPV of MRI BIRADS 3 (97% vs 89%, p < 0.05). The logistic regression analysis showed a higher number of malignant lesions in group 1 than in group 2 (7vs 2, OR 3.7, p < 0.05).

Conclusions

The second-look US permitted the correct management of subcentimetric MRI BIRADS 3 lesions not visible with conventional imaging tecniques.  相似文献   

14.

Purpose

To evaluate the diagnostic performance of three-dimensional (3D) MR maximum intensity projection (MIP) in the assessment of synovitis of the hand and wrist in rheumatoid arthritis (RA) compared to 3D contrast-enhanced magnetic resonance imaging (CE-MRI).

Materials and methods

Twenty-five patients with RA underwent MR examinations. 3D MR MIP images were derived from the enhanced images. MR images were reviewed by two radiologists for the presence and location of synovitis of the hand and wrist. The diagnostic sensitivity, specificity and accuracy of 3D MIP were, respectively, calculated with the reference standard 3D CE-MRI.

Results

In all subjects, 3D MIP images yielded directly and clearly the presence and location of synovitis with just one image. Synovitis demonstrated high signal intensity on MIP images. The k-values for the detection of articular synovitis indicated excellent interobserver agreements using 3D MIP images (k = 0.87) and CE-MR images (k = 0.91), respectively. 3D MIP demonstrated a sensitivity, specificity and accuracy of 91.07%, 98.57% and 96.0%, respectively, for the detection of synonitis.

Conclusion

3D MIP can provide a whole overview of lesion locations and a reliable diagnostic performance in the assessment of articular synovitis of the hand and wrist in patients with RA, which has potential value of clinical practice.  相似文献   

15.

Introduction

Diffusion weighted magnetic resonance imaging (DW MRI) is an imaging technique showing molecular diffusion. Cell size, density and integrity influence the signal intensity seen on diffusion-weighted images. This technique is a helpful complementary tool to distinguish tumoral from non tumoral tissue.The aim of this prospective study is to define the diagnostic accuracy of DWI to differentiate benign from malignant cervical lymph nodes.

Patients and methods

Twenty six patients who presented with 32 nodes were included in this study, 9 males (35.6%) and 17 females (65.4%). Their age ranged from: 6 to 76 years, mean age 45 ± 18.8 years referred to the radiology department of NCI, complaining of neck swelling, ultrasound showed cervical nodes.

Results

According to histopathological analysis we divided the examined lymph nodes (n = 32) into 2 categories: malignant lymph nodes 75% (n = 24) benign lymph nodes 25% (n = 8). DWI and ADC (apparent diffusion coefficient) values revealed 27 malignant lesions (84%), 5 benign (16%). The accuracy of the DWMRI was 89%. A significant difference between benign and malignant cervical nodes on DWI and on ADC maps is reported.The results obtained were 24 true positive, 3 false positive, 5 true negative. No false negative cases were identified, yielding a sensitivity of 100%, specificity of 62.5%, NPV = 100% and PPV = 89%. The difference between the mean ADC values between benign and malignant lesions was statistically significant (P < 0.0001).

Conclusion

MR diffusion imaging could be an important supportive tool in differentiation between benign and malignant lymph nodes, can to a lesser extent differentiate between the types of malignant lymphadenopathy and can be used as an indicator for improvement and recurrence post chemo and radiotherapy.  相似文献   

16.

Objective

To evaluate the impact of adding 18F-fluorine-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in the evaluation of suspicious breast lesions on magnetic resonance imaging (MRI).

Methods

Sixty patients with suspicious breast lesions on MRI were selected to perform a PET–CT in prone position, dedicated to the evaluation of the breasts. The areas with increased 18F-FDG concentration relative to normal parenchyma were considered positive on PET–CT. Fusion of PET and MRI images (PET–MRI) was performed on a dedicated workstation to better locate corresponding lesions, and its findings were compared with histological results.

Results

76 lesions were evaluated, including 64 mass lesions (84.2%) and 12 non-mass lesions (15.8%). Lesions’ mean diameter on MRI was 29.6 ± 19.2 mm (range 6–94 mm). PET–CT showed increased metabolically activity on 57 lesions (75.0%), with mean maximum SUV of 5.7 ± 5.0 (range 0.8–23.1). On histopathology, there were 17 (22.4%) benign and 59 (79.7%) malignant lesions. Considering all lesions, PET–MRI fusion provided 89.8% sensitivity, 76.5% specificity and 86.8% accuracy. Considering only mass lesions higher than 10 mm, PET–MRI fusion provided 95.8% sensitivity, 83.3% specificity and 93.3% accuracy.

Conclusion

The inclusion of 18F-FDG PET on the evaluation of suspicious breast lesions on MRI helped to differentiate benign from malignant breast lesions, especially for mass lesions with a diameter higher than 10 mm.  相似文献   

17.

Objective

To investigate whether the addition of diffusion-weighted imaging (DWI) to dynamic contrast-enhanced MRI (DCE-MRI) improves diagnostic performance in predicting pathologic response and residual breast cancer size following neoadjuvant chemotherapy.

Materials and methods

A total of 78 consecutive patients who underwent preoperative breast MRI with DWI following neoadjuvant chemotherapy were enrolled. DWI was performed on a 1.5 T system with b values of 0 and 750 s/mm. or on a 3 T system with b values of 0 and 800 or 0 and 1000 s/mm. The images on DCE-MRI alone, DWI alone, and DCE-MRI plus DWI were retrospectively reviewed. We evaluated the diagnostic performances of the three MRI protocols for the detection of residual cancer. The tumor size as predicted by MRI was compared with histopathologic findings. Apparent diffusion coefficient (ADC) values were also compared between the groups with and without residual cancer.

Results

Of the 78 patients, 59 (75.6%) had residual cancer. For detection of residual cancer, DCE-MRI plus DWI had higher specificity (80.0%), accuracy (91.0%), and PPV (93.2%) than DCE-MRI or DWI alone (P = 0.004, P = 0.007, and P = 0.034, respectively). The ICC values for residual cancer size between MRI and histopathology were 0.891 for DCE-MRI plus DWI, 0.792 for DCE-MRI, and 0.773 for DWI. ADC values showed no significant differences between residual cancer and chemotherapeutic changes (P = 0.130).

Conclusions

The addition of DWI to DCE-MRI significantly improved diagnostic performance in predicting pathologic response and residual breast cancer size after neoadjuvant chemotherapy.  相似文献   

18.

Purpose

To determine the accuracy of a probably benign assessment of non-palpable breast lesions (BI-RADS category 3) at mammography and/or ultrasound with immediate histological work-up.

Materials and methods

Stereotactic or ultrasound guided core needle breast biopsy (NBB) was performed to evaluate 288 lesions, which were prospectively assessed as BI-RADS category 3. Imaging findings included 195 masses, 73 calcification cases, 16 focal asymmetries, and four architectural distortion cases. After NBB, patients underwent either open surgical biopsy (OSB) (n = 204) or mammographic follow-up (n = 84) for at least 24 months. Histological results of NBB were compared with those of OSB.

Results

Three of the 288 lesions (1.0%) proved to be malignant at histological work-up, two of them were ductal carcinoma in situ (DCIS) and one of them was an invasive carcinoma. NBB revealed invasive carcinoma in 1/288 (0.35%) and atypical ductal hyperplasia (ADH) in 13/288 (4.5%) lesions. OSB revealed DCIS in 2/204 (1%) and invasive carcinoma in 1/204 (0.5%) lesions. The two DCIS were underestimated as ADH by NBB. The remaining 285 (99%) lesions proved to be benign at OSB or remained stable during follow-up.

Conclusion

Confirmed by tissue diagnosis, the low likelihood of malignancy of prospectively assessed probably benign lesions is below the 2% threshold established for BI-RADS category 3. Imaging follow-up is a safe and effective alternative to immediate histological work-up for such lesions.  相似文献   

19.

Purpose

The aim of this study is to assess the prevalence, the site and the nature of extra-mammary findings on breast magnetic resonance imaging (MRI) and to determine its accuracy in the characterization of the discovered lesions.

Materials and methods

A retrospective review of 308 female patients (mean age 50 ± 20) who underwent breast MRI with 1.5 T device was performed. 125 out of 308 (40.5%) had a positive personal history of breast cancer (pre-operative n = 80; follow-up n = 45), while the remaining 183 without history of breast cancer (high familiar risk for breast cancer n = 80; dense breast n = 103). All incidental findings were characterized by means of additional imaging (US; Bone scintigraphy-MRI; CT-PET-CT).

Results

59 incidental findings were found in 53/308 (17%) examined patients. 9/59 incidental findings (15%) were confirmed to be malignant while the remaining 50/59 (84%) benign. The most common site was the liver (33/59; 55.8%), followed by the lung (6/59; 10.1%), bone (6/59; 10.1%), diaphragm (6/59; 10.1%) spleen (3/59; 5%), kidney (2/59; 3.4%), gall bladder (1/5; 1.5%), ascending aorta (1/59; 1.5%), thyroid (1/59; 1.5%). The incidence of malignant incidental findings resulted to be higher in the group of patients with personal breast cancer (36%) than in the other one (8%). By comparing MRI findings with the additional definitive imaging tools, breast MRI allowed a correct diagnosis in 58/59 cases with a diagnostic accuracy value of 98%.

Conclusion

Incidental extramammary findings on breast MRI are common. Benign lesions represent the most frequent findings, however malignant ones need to be searched especially in patients with personal history of breast cancer because they could influence the clinical patient management. Breast MRI can characterize incidental findings with high accuracy value.  相似文献   

20.

Objectives

Preoperative magnetic resonance (MR) guided wire localization is a frequently used tool to target MR-only visible breast lesions. Different techniques are available. Targeting can be performed using automated software or a manual approach. Aim of this study therefore was to compare manually and automated software assisted wire localization of suspicious breast lesions regarding to image time and accurate positioning.

Methods

60 females with suspicious breast lesions underwent MR-guided wire localization. In 30 patients a manual target calculation and in another 30 patients a software calculated approach was used. Time measurements for MR imaging as well as calculation of the target coordinates were performed. Furthermore size measurements of (i) lesions, (ii) distance to wire anchor as well as, (iii) distance to skin were performed. A Mann-Whitney-test was used for statistical evaluation.

Results

Total imaging time was shorter for the automated software calculated approach but failed to show a statistical significant difference (p = 0.13). Time for localization of the lesions was significantly shorter for the software based method (p < 0.001). Lesion sizes, distances to wire anchor and skin showed no statistically significant differences.

Conclusions

Preoperative MR-guided wire localization of suspicious lesions that are accessible horizontally, a manually or automated software generated target calculation can be used. As MR guided wire localization of breast lesions needs its time in total, a minimal time consuming approach and therefore an automated software calculated targeting (if available) should be preferred.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号