1.
目的 评价99Tcm 1,2 双 [双 2 乙氧乙基膦 ]乙烷 (tetrofosmin)诊断冠心病的临床价值。方法 经冠脉造影、病历资料完整的 5 3例患者 ,其中行99Tcm tetrofosmin心肌灌注显像 2 7例 ,行99Tcm MIBI心肌灌注显像 2 6例。运动负荷试验按Bruce方案进行。Tetrofosmin显像于给药后 30min行心肌断层显像 ,间隔 2 4h后作静息心肌断层显像 ,运动 静息一日法则在 4h后作静息心肌断层显像 ;MIBI显像于给药后 1~ 2h行心肌断层显像 ,48h后作静息心肌断层显像。冠脉造影采用Judkins法。结果 99Tcm tetrofosmin心肌灌注显像 ,运动、静息显像以及运动 静息一日法心肌显像均获得了清晰的心肌断层图像 ,均未发现邻近器官有明显的放射性干扰。Tetrofosmin诊断冠心病的灵敏度为 90 % ,MIBI的诊断灵敏度为 94% ,两者间差异无显著性 (P >0 .0 5 )。Tetrofosmin的检测效率为 85 .2 % ,MIBI的检测效率为88.5 % ,两者间差异无显著性 (P >0 .0 5 )。Tetrofosmin和MIBI的阳性预测值分别为 90 .0 %和 89.5 % ,诊断特异性分别为 71%和 75 %。结论 99Tcm tetrofosmin心肌显像对冠心病心肌缺血具有较高的诊断价值 ,且适用于运动 静息一日法心肌显像  相似文献   

2.
99TCm-MIBI联合67Ga心肌显像诊断小儿病毒性心肌炎   总被引:5,自引:1,他引:4  
目的 探讨99Tcm 甲氧基异丁基异腈 (MIBI)心肌灌注显像联合6 7Ga心肌显像诊断小儿病毒性心肌炎 (VMC)的价值。方法  78例VMC患儿 ,其中急性期 (<6个月 ) 4 5例 ,慢性期 (>6个月) 33例 ,分别行99Tcm MIBI心肌灌注显像和6 7Ga心肌显像。结果  4 5例急性期患儿中 31例(6 8 9% ) 99Tcm MIBI心肌灌注显像出现不同程度的放射性分布异常 ,38例 (84 4 % ) 6 7Ga心肌显像示心脏部位异常放射性浓聚 ;33例慢性期患儿中 2 3例 (6 9 7% ) 99Tcm MIBI心肌灌注显像阳性 ,6 7Ga心肌显像仅10例 (30 3% )阳性。急性期两者结果差异无显著性 (P >0 0 5 ) ;慢性期两者差异有显著性 (P <0 0 5 )。结论 99Tcm MIBI心肌灌注显像联合6 7Ga心肌显像对诊断小儿VMC及观察病情演变有较高价值。  相似文献   

3.
目的 用99Tcm 甲氧基异丁基异腈 (MIBI)静息SPECT显像评价年轻心肌梗死患者的心肌损伤。方法 总结分析了 42例年龄 <40岁的心肌梗死患者99Tcm MIBI静息心肌灌注断层显像 ,并与冠状动脉造影和ECG进行比较。结果  42例年轻心肌梗死患者 ,90 % (38例 )心肌灌注显像异常 ,10 % (4例 )未见明显异常 ,诊断灵敏度为 90 %。与ECG相比 ,心肌灌注显像对梗死灶定位更准确 ,特别是心尖和后壁梗死。结论 心肌灌注显像显示年轻心肌梗死患者心肌受损较严重。  相似文献   

4.
目的 探讨静息2 0 1 Tl 负荷99Tcm 甲氧基异丁基异腈 (MIBI)双核素心肌SPECT显像在冠心病诊断中的价值。方法 对 36例冠心病患者行2 0 1 Tl负荷 延迟再分布心肌SPECT显像 ;常规潘生丁药物负荷高峰时 ,静脉注射2 0 1 Tl111~ 14 8MBq ,15min后进行心肌显像。对 2 3例冠心病患者和 9例正常人行静息2 0 1 Tl负荷、99Tcm MIBI双核素心肌SPECT显像 ,静息状态注射2 0 1 Tl111~ 14 8MBq ,注射后5min给予潘生丁药物负荷 ,高峰时注射99Tcm MIBI 92 5MBq。 1h后行双核素显像。结果  36例冠心病患者2 0 1 Tl负荷 延迟再分布心肌显像的阳性率为 83 33% ,2 3例冠心病患者双核素心肌显像的阳性率为 10 0 % ,两组阳性率比较差异有显著性 (χ2 =4 2 6 7,P =0 0 4 3)。 9例正常受检者均为阴性。结论双核素心肌显像对冠心病的检出率较高 ,省时、安全并可获得高质量图像 ,对冠心病诊断有较高临床价值。  相似文献   

5.
99Tcm-octreotide显像在乳腺癌诊断中的应用   总被引:2,自引:2,他引:0  
目的 探讨99Tcm 奥曲肽 (octreotide)显像对乳腺癌诊断的临床价值。方法  36例乳腺肿块患者 ,据手术及病理检查结果分为乳腺癌组 (19例 )和乳腺良性病变组 (17例 )。术前分次进行乳腺99Tcm octreotide及99Tcm 甲氧基异丁基异腈 (MIBI)显像 ,行定性及半定量 [放射性摄取比值 (UR)测定 ]分析。结果 99Tcm octreotide显像对乳腺癌诊断的灵敏度 (6 8 4 %)低于99Tcm MIBI (94 7%,P <0 0 5 ) ,特异性 (10 0 %)明显高于99Tcm MIBI(76 5 %,P <0 0 5 ) ,准确性 (83 3%)与99Tcm MIBI (86 1%)差异无显著性 (P >0 0 5 )。联合99Tcm octreotide与99Tcm MIBI显像特异性高 (10 0 %) ,但准确性(80 6 %)无明显变化 (P >0 0 5 )。结论 99Tcm octreotide显像对乳腺癌诊断特异性高 ,准确性与99Tcm MIBI显像无明显差别。  相似文献   

6.
目的 比较99Tcm tetrofosmin和99Tcm 甲氧基异丁基异腈 (MIBI)显像诊断乳腺癌和腋淋巴结转移的临床价值。方法 对 5 2例乳腺肿瘤患者进行99Tcm tetrofosmin和99Tcm MIBI显像。患者均在 2周内行外科手术治疗 ,并做病理检查。结果  2 6例患者病理检查证实为乳腺癌 ,其中 30例为良性病变。99Tcm tetrofosmin显像发现乳腺癌 2 1例 ,其中 11例合并腋淋巴结转移 ;99Tcm MIBI显像发现乳腺癌 19例 ,其中 12例合并腋淋巴结转移。99Tcm tetrofosmin和99Tcm MIBI显像对乳腺癌诊断的灵敏度、特异性和准确性分别为 80 8%、76 7%、78 6 %和 73 1%、73 3%、73 2 % ;诊断腋淋巴结转移的灵敏度、特异性和准确性分别为 6 8 8%、80 0 %、76 0 %和 75 0 %、80 0 %、76 9%。结论 99Tcm tetrofosmin显像对乳腺癌的检出优于99Tcm MIBI显像  相似文献   

7.
目的 探讨定量分析运动99Tcm 甲氧基异丁基异腈 (MIBI)心肌显像左室暂时性扩大诊断冠状动脉 (简称冠脉 ) 3支病变的价值。方法  76例拟诊冠心病患者 ,平均年龄 (6 1± 8 3)岁。间隔1个月内完成运动 静息99Tcm MIBI心肌断层显像和冠脉造影检查。根据心肌短轴断层影像直径方向剖面曲线 2个峰值点间的距离计算左心腔面积 (LVD) ,以运动 /静息LVD比值 (LVDR)作为判断左心腔暂时性扩大的指标。结果 冠脉造影正常组、冠脉 1支病变、2支病变和 3支病变组LVDR平均值分别为 1 0 1± 0 0 5、1 0 2± 0 0 5、1 0 5± 0 0 4和 1 13± 0 0 6。 76例拟诊冠心病患者中左室暂时性扩大者 2 1例 ,其中 ,有冠脉 3支病变者 19例 (90 % )。LVDR值诊断冠脉 3支病变的灵敏度和特异性分别为 82 %和 94% ,常规分析方法分别为 5 0 %和 91%。其灵敏度显著高于常规分析方法 (χ2 =4 96 ,P <0 0 5 ) ,特异性差异无显著性 (χ2 =1 31,P >0 0 5 ) ,2种分析方法结合 ,灵敏度进一步提高 ,而特异性无显著下降。结论 定量分析运动99Tcm MIBI心肌显像左心腔暂时性扩大可提高其诊断冠脉 3支病变的灵敏度 ,不降低其特异性 ,LVDR值是诊断冠脉 3支病变的 1个新的有用指标。  相似文献   

8.
目的 对比分析99Tcm 甲氧基异丁基异腈 (MIBI)和99Tcm 亚甲基二膦酸盐 (MDP)对骨良恶性病变的诊断价值和疗效评估。方法  6 1例临床拟诊骨良恶性病变患者分别进行 2项骨显像 ,其中 6例恶性肿瘤患者分别进行化疗前后显像。显像后均经手术、病理检查对比分析。结果 99Tcm MIBI显像 :73 %恶性肿瘤病灶肉眼见中、高度MIBI浓聚 ,6 0 %良性病灶肉眼未见MIBI聚集。恶性病灶部位与对侧正常组织放射性计数比值 (L C)即99Tcm MIBI摄取比值 (3 0 8± 1 6 7)明显高于良性病灶(1 36± 0 6 4) ,P <0 0 1。99Tcm MDP显像 :大多数恶性或良性病灶肉眼见中、高度MDP浓聚 ,但恶性病灶99Tcm MDPL C(3 76± 1 37)与良性病灶L C(3 10± 1 0 5 )比较差异无显著性 (P >0 0 5 )。化疗可以抑制99Tcm MIBI摄取 ,99Tcm MIBI摄取程度与99Tcm MDP比较能较好反应治疗效果。结论 99Tcm MIBI对鉴别诊断良恶性骨病和评估疗效有较好的应用价值 ,与99Tcm MDP显像联合应用可更全面地提供信息  相似文献   

9.
目的 探讨99Tcm 甲氧基异丁基异腈 (MIBI)门控心肌显像可逆性局部室壁运动异常(RWMA)对判断冠状动脉 (简称冠脉 )狭窄程度的价值。方法  116例疑诊冠心病患者 ,在行运动 静息99Tcm MIBI门控心肌显像前后 2周内进行冠脉造影 (CAG)。运动显像于运动后 15~ 2 0min内进行图像采集 ;应用 2 0节段 5分制进行室壁运动及增厚率评分。结果 用心肌显像可逆性RWMA判断狭窄程度≥ 75 %冠脉狭窄的灵敏度为 6 5 % ,特异性为 97% ;用可逆性RWMA区别严重冠脉狭窄 (≥75 % )和不严重冠脉狭窄 (<75 % )有较高的阳性预测值 (98% )。多因素分析示负荷室壁运动总积分(SSSWM)、室壁运动差分值 (SDSWM)和运动显像灌注总积分 (SSS)是濒危冠脉积分的独立危险因子。结论 根据99Tcm MIBI门控心肌显像可逆性RWMA判断严重冠脉狭窄特异性和阳性预测值较高。运动后及可逆性RWMA可提高心肌灌注显像对冠脉狭窄程度的评估价值。  相似文献   

10.
目的 评价^99Tc^m-1,2-双[双-2-乙氧乙基膦]乙烷(tetrofosmin)诊断冠心病的临床价值。方法 经冠脉造影、病历资料完整的53例患者,其中行^99Tc^m-tetrofosmin心肌灌注显像27例,行^99Tc^m-MIBI心肌灌注显像26例。运动负荷试验按Bruce方案进行。tetrofosmin显像于给药后30min行心肌断层显像,间隔24h后作静息心肌断层显像,运动-静息一日法则在4h后作静息心肌断层显像;MIBI显像于给药后1-2h行心肌断层显像,48h后作静息心肌断层显像。冠脉造影采用Judkins法。结果 ^99Tc^m-tetrofosmin心肌灌注显像,运动,静息显像以及运动-静息一日法心肌显像均获得了清晰的心肌断层图像,均未发现邻近器官有明显的放射性干扰。Tetrofosmin诊断冠心病的灵敏度为90%,MIBI的诊断灵敏度为94%,两者间差异无显著性(P>0.05)。Tetrofosmin的检测效率为85.2%,MIBI的检测效率为88.5%,两者间差异无显著性(P>0.05)。Tetrofosmin和MIBI的阳性预测值分别为90.0%和89.5%,诊断特异性分别为71%和75%。结论 Tetrofosmin心肌显像对冠心病心肌缺血具有较高的诊断价值,且适用于运动-静息一日法心肌显像。  相似文献   

11.
缺血心肌99Tcm-MIBI清除率变化的临床研究   总被引:1,自引:0,他引:1  
目的 探讨缺血性心脏病(IHD)患者心肌99Tcm-甲氧基异丁基异腈(MIBI)早期、晚期清除率的变化及其评估缺血心肌细胞功能障碍的价值.方法 对临床诊断为IHD并满足冠状动脉三支主要分支狭窄均≥50%、除外心肌梗死的16例患者行99Tcm-MIBI静态平面及门控心肌灌注断层显像.用t检验比较99Tcm-MIBI早期(注药后90 min)、晚期(注药后4 h)清除率及左心室射血分数(LVEF)与健康对照组(10名)的差异,并对早期、晚期清除率与LVEF行直线相关分析.结果 IHD组早期、晚期心肌清除率及LVEF分别为(13.44±2.87)%、(19.24±4.71)%和(55.71±7.97)%,健康对照组分别为(17.32±4.92)%、(15.23±3.81)%和(67.75±5.43)%,2组相比差异均有统计学意义(t值分别为2.384,-2.246及-4.418,P均<0.05).早期及晚期清除率与LVEF不具有相关性,r值分别为-0.212(P>0.05)及0.352(P>0.05).结论 IHD患者心肌99Tcm-MIBI清除率异常可反映缺血引起的细胞功能损伤.  相似文献   

12.
目的评价腺苷和运动负荷心肌灌注显像诊断不典型胸痛患者心肌缺血的价值。方法不典型胸痛患者67例行腺苷负荷心肌灌注显像,81例行运动负荷心肌灌注显像,结果分别与冠状动脉(简称冠脉)造影比较,得到显像诊断冠心病心肌缺血的灵敏度、特异性和准确性。结果腺苷负荷心肌灌注显像组67例中,23例冠脉造影有狭窄病变,腺苷负荷心肌灌注显像检出可逆性灌注异常即诊断心肌缺血16例,44例冠脉造影阴性者中,腺苷心肌灌注显像正常41例。腺苷负荷心肌灌注显像诊断冠心病心肌缺血的灵敏度为70%,特异性93%,准确性85%。运动负荷心肌灌注显像组81例中,31例冠脉造影阳性,运动负荷心肌灌注显像检出心肌缺血22例,50例冠脉造影阴性者中,运动负荷心肌灌注显像正常48例。运动负荷心肌灌注显像诊断冠心病心肌缺血的灵敏度为71%,特异性96%,准确性86%。结论腺苷或运动负荷心肌灌注显像出现可逆性灌注异常对诊断不典型胸痛患者冠心病心肌缺血有重要意义。  相似文献   

13.
To evaluate the clinical efficacy of 99Tcm-MIBI myocardial tomography for detecting coronary artery disease (CAD) 115 consecutive patients who underwent both 99Tcm-MIBI single photon emission computed tomography (SPECT) and coronary arteriography were studied. Thirty-three patients without and 82 with significant coronary artery disease were documented by coronary arteriography. The overall sensitivity and specificity of 99Tcm-MIBI SPECT for detecting coronary artery disease were 96 and 87.9%, respectively. The sensitivity for identifying patients with CAD without myocardial infarction was 88%. The sensitivity of 99Tcm-MIBI SPECT for detecting individual coronary artery lesions was 86% for left anterior descending artery (LAD), 69% for left circumflex artery (Lcx) and 86% for right coronary artery (RCA), lesions respectively. In conclusion, 99Tcm-MIBI SPECT provides a reliable method for detecting CAD.  相似文献   

14.
目的 探讨核素心肌灌注显像对代谢综合征患者并发冠心病的诊断价值.方法 回顾性分析251例[男179例,女72例,年龄(59±10)岁]代谢综合征患者99Tcm-甲氧基异丁基异腈(MIBI)心肌灌注显像的结果,与冠状动脉造影进行比较,计算99Tc-MIBI心肌灌注显像诊断冠心病的灵敏度、特异性和准确性.结果 在251例代谢综合征患者中,163例(65%)患者冠状动脉造影示有狭窄病变,99Tcm-MIBI心肌灌注显像检出心肌缺血或心肌梗死116例;88例冠状动脉造影阴性患者中,82例心肌灌注显像结果正常;99Tcm-MIBI心肌灌注显像诊断冠心病的灵敏度为71%(116/163),特异性为93%(82/88),阳性预测值为95%(116/122),阴性预测值为64%(82/129),准确性为79%(198/251).诊断单支、双支和三支冠状动脉病变患者的灵敏度分别为58%(36/61),61%(22/36)和87%(57/66).结论 99Tcm-MIBI心肌灌注显像对检测代谢综合征患者有无并发冠心病有重要的应用价值.  相似文献   

15.
目的 探讨心肌灌注显像对症状性冠状动脉(以下简称冠脉)心肌桥患者的临床应用价值.方法 回顾性分析19例因胸痛、胸闷等症状行冠脉造影排除阻塞性冠脉狭窄,诊断为心肌桥并接受运动-静息99Tcm-甲氧基异丁基异腈(MIBI)心肌灌注显像的患者资料,分析心肌灌注显像结果,并与运动心电图、冠脉造影结果比较.应用Stata 7.0软件,对符合正态分布的计量资料行t检验比较,用χ2检验分析组间频数差别.结果 19例症状性心肌桥患者冠脉造影示收缩期冠脉狭窄程度为(65.4±22.1)%,18例为左前降支肌桥、1例为左前降支合并左回旋支肌桥.运动-静息心肌灌注显像示心肌缺血10例、正常9例,其中心肌缺血位于前壁和(或)心尖部8例、下壁1例、后侧壁和后间壁1例;心肌灌注显像诊断心肌缺血的阳性率为52.6%(10/19),明显高于运动心电图的21.1%(4/19)=4.07,P<0.05.19例心肌桥患者按Nobel分级法,Ⅰ级狭窄5例、Ⅲ级狭窄6例、Ⅲ级狭窄8例;Ⅰ级狭窄患者中1例心肌灌注显像心肌缺血阳性,Ⅱ级狭窄患者中2例阳性,Ⅲ级狭窄患者中7例阳性.心肌桥患者心肌灌注显像心肌缺血组收缩期冠脉狭窄明显高于心肌灌注显像正常组[(78.0±4.7)%与(52.8±6.7)%,t=3.06,P<0.01],2组肌桥长度差异无统计学意义[(15.1±2.1)mm与(11.8±1.0)mm,t=1.43,P>0.05].结论 运动-静息心肌灌注显像能有效评价症状性心肌桥患者所致心肌缺血,明确心肌桥与临床症状的关系及其临床意义.  相似文献   

16.
The aim of this study was to compare the clinical value of 99Tcm-MIBI single photon emission tomography (SPET) and electron beam computed tomography (EBCT) in the assessment of coronary artery disease (CAD) in different age groups. 99Tcm-MIBI SPET (stress-rest), EBCT and coronary angiography studies were performed in 64 consecutive patients with suspected CAD. The patients were classified into two groups: Group A = 40 patients > 45 years of age and Group B = 24 patients < or = 45 years of age. There were 31 and 14 patients with coronary stenosis > or = 50% as determined by coronary angiography in Groups A and B, respectively. All patients (30 cases) with abnormal 99Tcm-MIBI myocardial SPET and coronary calcification detected by EBCT had significant coronary artery disease, and 93.3% of the patients with normal 99Tcm-MIBI SPET and normal EBCT had normal coronary angiography or < 50% lumen narrowing of the coronary arteries. In Group B, the sensitivity of SPET for detecting CAD was significantly higher than that of EBCT (92.9 vs 42.9%, P < 0.01); the specificity of SPET was comparable to that of EBCT. In Group A, there was no significant difference between SPET and EBCT in terms of sensitivity (93.6 vs 90.3%) or specificity (88.9 vs 55.6%). However, in the detection of individual coronary artery disease, the specificity of SPET was significantly higher than that of EBCT in Group A (94.1 vs 66.7%, P < 0.001). The sensitivity of SPET was again significantly higher than that of EBCT (85.7 vs 38.1%, P < 0.005) in Group B. The accuracy of SPET was higher than that of EBCT in both groups (82.5 vs 67.5%, P < 0.01 in Group A; 93.1 vs 76.4%, P < 0.01 in Group B, respectively). We conclude that 99Tcm-MIBI myocardial perfusion SPET has a higher sensitivity than EBCT in the detection of CAD in patients < or = 45 years old and a higher specificity in patients > 45 years of age. A combination of SPET and EBCT may assess CAD more accurately.  相似文献   

17.
双核素心肌显像检测存活心肌的对比研究   总被引:2,自引:0,他引:2  
目的 对比多巴酚丁胺负荷201Tl/静息99Tcm-甲氧基异丁基异腈(MIBI)双核素同步心肌断层显像及多巴酚丁胺负荷-再分布/再注射201Tl心肌断层显像法检测存活心肌的作用.方法 对160例临床怀疑有冠心病的患者予静息状态下静脉注射740 MBq99Tcm-MIBI,休息15 min后进行多巴酚丁胺负荷试验,在达到终止指标时静脉注射111 MSq201TICI.注射后观察5-lO min,分别行早期(10 min)、延迟(3 h)99Tcm-MIBI和201Tl双核素同步心肌断层显像.对早期负荷201Tl图像发现放射性缺损,延迟再分布201Tl和静息99Tcm-MIBI图像未见放射性填充的患者再注射37 MBq201TICI,30min后行再注射心肌灌注显像.负荷枷201Tl图像示放射性缺损,静息99Tcm-MIBI、再分布201Tl及再注射201Tl图像中发现任何一种放射性填充者均为存活心肌.断层显像后2周内全部患者进行了冠状动脉造影.采用SAS 6.12软件进行x2检验.结果 (1) 160例患者冠状动脉造影均发现冠状动脉狭窄.其中单支病变76例、双支病变5l例、三支病变33例.(2)152例多巴酚丁胺负荷201Tl图像发现放射性缺损的患者中,63例201Tl再分布和静息99Tcm-MIBI图像均发现放射性填充,5例201Tl再分布发现放射性填充而静息99Tcm-MIBI图像未见放射性填充,9例静息99Tcm-MIBI图像发现放射性填充而2001Tl再分布未见放射性填允,75例201Tl再分布和静息99Tcm-MIBI图像均未发现放射性填充,负荷201Tl-延迟再分布显像(66.0%,68/103)和负荷201Tl/静息99Tcm-MIBI显像(69.9%,72/103)鉴别存活心肌的灵敏度差异无统计学意义(x2=O.36,P>0.05).(3)75例201Tl再分布和静息99Tcm-MIBI图像均未发现放射性填充患者中,再注射201Tl显像后有26例放射性填充,再注射201Tl显像较单纯201Tl再分布或静息99Tcm-MIBI显像多检测出34.7%(26/75)患者有存活心肌.(4)8例多巴酚丁胺负荷201Tl、201Tl再分布图像和静息99Tcm-MIBI图像均未发现放射性稀疏,为假阴性,其中3例为三支冠状动脉病变,1例为双支冠状动脉病变(狭窄分别为90%及60%),3例为单支冠状动脉病变(狭窄<75%2例,85%1例),1例冠状动脉闭塞后有充分的侧枝循环.结论 多巴酚丁胺负荷-再分布/再注射201Tl心肌断层显像鉴别存活心肌优于多巴酚丁胺负荷201Tl/静息99Tcm-MIBI双核素同步心肌断层显像,是一种有效、无创的鉴别存活心肌的方法.  相似文献   

18.
目的 探讨99Tcm-MIBI动态血流灌注显像和双时相显像对甲状腺冷结节良恶性的诊断价值.方法 回顾性分析甲状腺冷结节行手术治疗的患者28例,所有患者使用配备低能高分辨准直器的SPECT仪行99Tcm-MIBI动态血流灌注、30 min早期相及120 min延迟相静态平面显像,并用T/NT值等综合分析显像结果.结果 9例甲状腺癌患者在动态血流灌注、30 min早期相和120 min延迟相显像中阳性数分别为5例、6例、7例;19例良性病变患者在动态血流灌注、30 min早期相和120 min延迟相显像中阴性数分别为14例、11例、16例.99Tcm-MIBI动态血流灌注显像诊断甲状腺癌的灵敏度为55.56%,特异度为73.68%,准确率为67.85%;30 min早期相显像诊断甲状腺癌的灵敏度为66.67%,特异度为57.89%,准确率为67.85%;120 min延迟相显像诊断甲状腺癌的灵敏度为77.78%,特异度为84.21%,准确率为82.14%.结论 99Tcm-MIBI的双时相显像对甲状腺冷结节的诊断和鉴别诊断具有一定价值,通过对动态血流灌注和99Tcm-MIBI的双时相显像中T/NT值等综合分析,可以降低假阳性和假阴性的发生.  相似文献   

19.
目的 在正常和心肌梗死犬模型上,研究99TcmN-2-巯基吡啶-N-氧化物(99TcmN-MPO)的药物代谢动力学特征、生物学分布特征和对急性心肌梗死的诊断能力,并与传统示踪剂99锝m-甲氧基异丁基异腈(99Tcm-MIBI)进行对比研究.方法 正常杂种犬12只.静脉注射99TcmN-MPO,于不同时间点(30 s及1、2、3、4、5、10、20、30、40、60和90 min)静脉分别采血1 ml,经γ探测器测量其放射活性;注药后10、20、30、60、90及120 min行全身SPECT显像,并于不同器官上各取同样大小的ROI,测量其放射性计数进行定量研究.每只犬均注射相同剂量的99TcmMIBI,进行相同的实验作为对照.介入学方法构建犬急性心肌梗死模型,24 h后,静脉注入99TcmN-MPO(5只)和99Tcm-MIBI(5只),并于注药后30、60min进行心肌SPECT显像.结果 在静脉注射90 min内,99TcmN-MPO和99Tcm-MIBI均表现为快速的血液清除.两种示踪剂的初始注射剂量均为370 MBq.注射后1 min,每毫克血浆的放射活性小于初始注射剂量的50%[99TcmN-MPO为(35.77±6.31)%ID/mg;99Tcm-MIBI为(34.46±6.83)%ID/mg],30 min时<5%[99TcmN-MPO:(3.11±1.44)%ID/mg;99Tcm-MIBI:(2.93±0.39)%ID/mg].99TcmN-MPO在心脏的浓聚明显,且存留时间很长,由于其在肝脏清除的速度较快,因此可获得良好的心/肝摄取比值,注射后10 min为0.54±0.06,30 min为1.02±0.06,60 min上升到1.38±0.06.相比之下,99Tcm-MIBI的心/肝摄取比值上升较为缓慢(注射后10 min为0.46±0.03,30 min为0.63±0.03,60 min为0.62±0.12).犬心肌梗死后SPECT心肌断层扫描显示,在注射99TcmN-MPO 30 min后,心脏与肝脏分界清楚,可清楚显示心肌缺血、梗死灌注缺损区域、范围和程度;而99Tcm-MIBI注射后60 min,心脏和肝脏的分界依然不清,尤其是肝脏的高放射性对心脏下壁和左心室壁的影响很大,对心脏左心室壁的心肌梗死灌注缺损区域的显示不佳.结论 99TcmN-MPO具有心肌摄取量较高,肝脏代谢快的特点,是一种具有广阔临床应用前景的SPECT心肌灌注成像显像剂.
Abstract:
Objective The purpose of the present study is to compare the pharmacokinetic and biodistribution properties of 99Tcm N-mercaptopyridine-N-oxide (99 Tcm N-MPO) with 99 Tcm-sestamibi (99 Tcm-MIBI) in normal dogs, and to investigate the potential of 99TcmN-MPO as a myocardial perfusion agent in canines with acute myocardial infarction. Methods Twelve healthy mongrel dogs were injected intravenously with 99TcmN-MPO (n = 6) or 99Tcm-MIBI (n = 6). Tracer kinetics in body fluids were determined by collecting blood of 1 ml via a femoral vein catheter at 30 s, 1,2,3,4,5, 10, 20, 30, 40, 60and 90 min post-injection (p. i.). The collected blood samples were weighed and counted for radioactivity in a γ-counter. Anterior and posterior planar γ-camera images were collected at 10, 20, 30, 60, 90, and 120 min after injection, with organ uptake quantified by region-of-interest (ROIs) analysis. For comparison, 99Tcm-MIBI was also evaluated in the same twelve dogs. Canine infarct models were set up by micro-invasive interventional embolization. SPECT images in the canine infarct model were collected 24 hours after myocardial infarction at 30 min and 60 min after the administration of 99Tcm N-MPO (n = 5) or 99Tcm-MIBI (n = 5). Results Both of 99Tcm N-MPO and 99Tcm-M1BI had a rapid blood clearance with less than 50% of initial radioactivity remaining at 1 min [99TcmN-MPO: (35. 77 ± 6. 31)% ID/mg ,99Tcm-MIBI (34. 46 ± 6. 83) % ID/mg] and less than 5% at 30 min p. i. [99Tcm N-MPO(3. 11 ± 1.44) % ID/mg,99Tcm-MIBI (2.93 ±0. 39)% ID/mg] . After injection, 99TcmN-MPO showed significant accumulation in the myocardium and prolonged retention. This rapid liver clearance of 99TcmN-MPO led to favorable heart-to-liver ratios, reaching values of 0. 54 ±0. 06 at 10 min, 1.02 ±0. 06 at 30 min, and 1.38 ±0. 06 at 60 min p. i.In contrast, the heart/liver ratio of 99Tcm-MIBI remained low at all time points (0. 46 ± 0. 03 at 10 min,0. 63 ±0. 03 at 30 min, and 0. 62 ± 0. 12 at 60 min p. i.). SPECT imaging studies in canines with acute myocardial infarction indicated that good visualization of the left ventricular wall and perfusion defects could be achieved at 30 min after administration of 99TcmN-MPO, but not 99Tcm-MIBI. Conclusion The combination of high heart uptake and rapid liver clearance makes 99TcmN-MPO a promising new radiotracer for myocardial perfusion imaging.  相似文献   

20.
A new non-invasive test for the detection of compartment syndromes   总被引:1,自引:0,他引:1  
Chronic exertional compartment syndrome (CECS) is currently diagnosed using invasive pressure measurements. We report the use of 99Tcm-methoxyisobutyl isonitrile (99Tcm-MIBI) scintigraphy as a new non-invasive method of diagnosis. Forty-six patients with suspected chronic compartment syndrome underwent graded treadmill exercise to reproduce the presenting symptoms. At peak exercise, 300 MBq of 99Tcm-MIBI were injected intravenously. Subsequent cross-sectional imaging provided by emission tomography demonstrated regional abnormalities in muscle perfusion in the calf. A repeat study was performed at rest the following day. All patients in whom there was a strong clinical suspicion of CECS were considered for invasive pressure measurements. Statistical analysis of the results for investigation of CECS using 99Tcm-MIBI versus pressure studies gave P = 0.06. A comparison of 99Tcm-MIBI versus outcome gave P < 0.0001. The sensitivity was 80% and the specificity 97% for 99Tcm-MIBI studies based on outcome. The positive predictive value was 89% and the negative predictive value 94%. Thus 99Tcm-MIBI can detect compartment syndromes with good positive and negative predictive values. It is relatively simple, cheap and less invasive than pressure measurements. This technique shows promise in the diagnosis of CECS.  相似文献   