 共查询到20条相似文献,搜索用时 78 毫秒
1.
目的 探讨双源CT低管电压冠状动脉成像技术的应用价值及不同心率对图像质量和辐射剂量的影响。方法 对323例临床怀疑冠心病患者进行双源CT低管电压(100 kVp)和常规管电压回顾性心电门控冠状动脉成像增强扫描,检查前不使用β受体阻滞剂控制心率。按患者扫描时的平均心率对低管电压组201例进行分组,≤59 次/min为A组(50例),60~69次/min为B组(64例),70~91次/min为C组(62例),≥91次/min为D组(25例)。对照组(管电压120 kVp)为E组(122例)。评价各组的最佳重建时相图像,记录各组的增强扫描序列的螺距、CT容积剂量指数(CTDIvol)、剂量长度乘积(DLP)及有效剂量(E)值,比较各组患者的扫描螺距、图像质量评分和辐射剂量值等,分析心率对图像质量和辐射剂量的影响。结果 A~D 4组螺距分别为(0.24±0.03)、(0.29±0.04)、(0.33±0.05)、(0.38±0.06),差异有统计学意义(F=62.57,P<0.05);A~E 5组CTDIvol值分别为(21.59±7.97)、(20.24±6.03)、(18.23±7.55)、(18.14±5.75)、(38.62±16.21)mGy(F=85.16, P<0.05);E值分别为(5.31±2.18)、(4.85±1.70)、(4.49±1.86)、(4.37±1.50)、(8.75±4.07)mSv(F=44.83, P<0.05);图像评分分别为(4.65±0.46)、(4.55±0.53)、(4.55±0.53)、(4.47±0.72)、(4.66±0.44)分(F=1.89,P>0.05)。结论 双源CT低管电压(100 kVp)技术冠状动脉成像在不控制心率情况下可获得较好的图像质量;在自动心电门控剂量窗时,中低心率对辐射剂量的影响较小,高心率可使有效辐射剂量降低,但获得优质图像质量的可能性减小。  相似文献   

2.
目的 探讨CT不同扫描方案检查所致婴幼儿眼晶状体吸收剂量估算方法,并寻求快速估算眼晶状体吸收剂量的实用方法。方法 通过设置7种临床标准扫描方案,对1岁年龄组仿真模体进行扫描,利用布放在模体不同位置的热释光探测器(TLD)测量剂量,最后测量结果分别用组织因子转换和个人剂量当量转换两种方法来估算眼晶状体吸收剂量,同时将眼晶状体吸收剂量与CT剂量指数(CTDI)建立线性回归方程。结果 7种临床标准儿童扫描方案CT检查所致的婴幼儿眼晶状体吸收剂量分别为(9.96±0.69)mGy(头部轴向)、(7.01±0.42)mGy(头部螺旋)、(12.60±0.97)mGy(副鼻窦)、(12.97±0.42)mGy(内耳高分辨)、(0.63±0.03)mGy(颈部软组织)、(8.89±0.44)mGy(颈部颈椎)和(0.34±0.01)mGy(胸部常规),不同组之间剂量差异有统计学意义(F=846.826,P<0.05)。不同扫描部位,CTDI值与眼晶状体吸收剂量之间均存在线性关系(r=0.986~0.999,P<0.05)。结论 采用儿童CT扫描条件,婴幼儿眼晶状体吸收剂量单次剂量范围一般不会超过阈剂量。另外,通过读取CTDI值,利用线性关系,可快速估算眼晶状体吸收剂量。  相似文献   

3.
目的 探讨胸主动脉CT血管造影(CTA)成像时的适应性统计迭代重建(ASIR)的最佳权重和优化低剂量扫描参数.方法 将体质量指数为19~24 kg/m2的120例患者随机数字表法分成6组,用宝石能谱CT进行胸主动脉CTA扫描,扫描范围为290~330 mm,第1组扫描条件为机器默认的100 kV、240 mAs,使用10%~100%权重的适应性统计迭代重建,对图像进行重建并计算信噪比(SNR)及对比度噪声比(CNR),请两位影像学家对图像进行5分值主观评价,优选出最佳图像质量的ASIR权重,在此权重基础上固定100 kV,用210、180、 150、120 及90 mAs对其他5组患者进行扫描,记录不同mAs的CTDIvol及DLP,并转换为有效剂量E.计算上述图像的SNR及CNR,并进行主观评价.结果 100 kV、240 mAs 扫描条件下图像的最佳ASIR权重为60%.ASIR权重为60%、100 kV下240~90 mAs扫描产生图像进行主观评价分值分别为(4.78±0.30)~(3.15±0.23);其CTDIvol、DLP平均值分别为: 12.64~4.41 mGy和331.81~128.27 mGy,并将DLP转换为E为4.98~1.92 mSv.120~240 mAs各组的影像质量差异无统计学意义(F=5.365,P>0.05),但120 mAs的CTDIvol、DLP及E较240 mAs分别低53.4%、48.5%及49.9%. 结论 在进行胸主动脉低剂量CTA成像时最佳的ASIR权重为60%.体质量指数为19~24 kg/m2的被检者胸主动脉低剂量CTA扫描的最佳mAs 为120 mAs (100 kV时).  相似文献   

4.
目的 对比分析婴幼儿先心病双源CT(DSCT)前瞻性心电触发血管造影中,Flash(大螺距扫描)与序列扫描两种模式的辐射剂量和图像质量。方法 60例临床拟诊先天性心脏病并进行DSCT前瞻性心电触发扫描的患儿纳入研究并随机分为2组,A组30例采用Flash扫描模式, B组30例采用序列扫描模式。比较两组容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效辐射剂量(E)以及CT图像质量,并以手术或心脏造影(DSA)结果为标准,比较两组诊断符合率。结果A、B两组CTDIvol分别为(0.32±0.10)和(1.40±0.43)mGy(t=13.32,P<0.05); DLP分别为(6.46±1.92)和(17.91±4.80)mGy·cm(t=7.97,P<0.05);E分别为(0.19±0.05)和(0.45±0.12)mSv(t=16.64,P<0.05);图像质量评分分别为(4.03±1.15)和(3.13±1.38)(t=3.55,P<0.05);A、B两组总诊断符合率分别为100%和93%,差异无统计学意义;但A组畸形检出率(91%)高于B组(75%)(χ2=7.72,P<0.05)。结论 在婴幼儿先心病DSCT血管造影中,采用Flash扫描模式时畸形检出率高于序列模式,且有效辐射剂量降低。  相似文献   

5.
目的 探讨智能最佳kV(CARE kV)技术在成人胸部CT成像的应用及其对降低辐射剂量的价值。方法 将69例患者按随机数字表法分成A、B两组,A组39例,行CARE kV技术扫描;B组30例,行标准120 kV技术扫描。比较两组CT剂量指数(CTDIvol)、剂量长度乘积(DLP)和有效剂量(E)以及分析A组管电压的选择与体重指数(BMI)关系。结果 A组平均CTDIvol(11.00±3.89)mGy、DLP(294.05±91.17)mGy·cm及E(4.12±1.28)mSv分别低于B组(16.64±1.20)mGy、(475.99±41.16)mGy·cm、(6.66±0.58)mSv(t=-7.653、-10.151、-10.150,P<0.05),与B组比较,A组总体E降低了38.14%。A组实际使用电压范围80~140 kV,管电压的选择与患者BMI呈正相关(r=0.627,P<0.05)。A组中非肥胖组患者E较肥胖组(BMI≥28 kg/m2)减少了31.74%(t=4.322,P<0.05),而B组中非肥胖组患者E与肥胖组患者差异无统计学意义。结论 胸部CT成像中,CARE kV技术能够根据患者体型和解剖部位的不同而自动地选择管电压和调整管电流,从而能够在保证图像诊断质量的同时显著降低总体辐射剂量。  相似文献   

6.
目的 通过改变扫描位置优化下颌骨CT扫描方法降低辐射剂量.方法 50例下颌骨CT扫描的连续病例纳入本前瞻性对照研究,用随机数字表法分2组,各25例.分别进行体位优化法和常规法扫描,比较其图像质量、CT 剂量加权指数(CTDIvol)、扫描范围长度(L)及剂量长度乘积(DLP).结果 体位优化法与常规法的下颌骨图像质量相同,两组的CTDIvol 无明显差异,体位优化法扫描范围长度(L)和剂量长度乘积(DLP) 比常规法分别下降20%(t=4.986, P<0.05) 和16%(t=3.682, P<0.05),并避开了晶状体.结论 体位优化法下颌骨扫描能有效减少扫描长度和避开晶状体,降低有效辐射剂量.  相似文献   

7.
目的 探讨儿童髋关节CT检查时降低管电流对图像质量的影响。方法 随机选儿童髋关节CT扫描45例,分常规剂量组、低剂量Ⅰ组(<6岁)和低剂量Ⅱ组(6~12岁)。记录容积CT剂量指数(CTDIvol)和扫描长度,计算出平均剂量长度乘积(DLP)。由专家对不同扫描参数的软组织窗和骨密度算法重建的骨窗图像质量分别进行评分,并进行统计学处理。结果 常规剂量组、低剂量Ⅰ组和Ⅱ组的CTDIvol分别为35.4、15.8、17.3 mGy,DLP分别为(442.75±23.51)、(197.91±18.46)和(216.01±14.25) mGy·cm。各组可满足临床诊断要求的图像的比例差异无统计学意义(P>0.05)。结论 儿童髋关节CT检查时应采用低剂量扫描技术,既减少辐射剂量,又能保证图像质量,满足临床诊断的要求。  相似文献   

8.
目的 比较容积CT剂量指数(CTDIvol)及体型特异性剂量评估(SSDE)在估算腹部CT扫描时患者所受辐射剂量的差异。方法 采用Philips 256螺旋CT扫描仪对180例患者进行上腹部CT增强扫描,在左肾静脉主干层面测量每例患者的左右径(LAT)、前后径(AP),计算有效直径(ED),同时记录每例被检者的CTDIvol值及体模的扫描直径,计算SSDE。将患者按照体质量指数(BMI)分为3组:A组,BMI<20.0 kg/m2;B组,BMI介于20.0~24.9 kg/m2之间;C组,BMI>24.9 kg/m2。分别比较180例被检者及不同体质量指数组CTDIvol与SSDE之间的差异。结果180例被检者CTDIvol和SSDE分别为(9.91±2.91)和(14.01±2.82)mGy,差异有统计学意义(t=-13.354, P<0.01)。A组CTDIvol和SSDE分别为(7.96±1.83)和(12.83±2.52)mGy (t=-8.417, P<0.01);B组分别为(9.28±1.76)和(13.62±2.18)mGy(t=-15.051,P<0.01);C组分别为(12.19±3.65)和(15.39±3.47)mGy(t=-4.535,P<0.01)。此外,3组SSDE分别较CTDIvol平均增加了62.83%、 47.80%和28.40%,即CTDIvol过低估算被检者的辐射剂量,且随着体质量指数的增加,CTDIvol与SSDE之间的差值越小。结论 SSDE能够反映特定体型的被检者进行腹部CT扫描时所接受的辐射剂量。  相似文献   

9.
目的 比较容积CT剂量指数(CTDIvol)及体型特异性剂量估算(SSDE)在估算腹部CT扫描时患者所受辐射剂量的差异。方法 采用Philips 256螺旋CT扫描仪对180例患者进行上腹部CT增强扫描,在左肾静脉主干层面测量每位患者的左右径(LAT)、前后径(AP),计算有效直径(ED),同时记录每位被检者的CTDIvol值及体模的扫描直径,计算SSDE。将患者按照体重指数(BMI)分为3组:A组,BMI<20 kg/m2;B组,BMI介于20~24.9 kg/m2之间;C组,BMI>24.9 kg/m2。分别比较180例被检者及不同体重指数组CTDIvol与SSDE之间的差异。结果 180例被检者CTDIvol和SSDE分别为(9.91±2.91)和(14.01±2.82)mGy,差异有统计学意义(t=-13.354,P=0.000)。A组CTDIvol和SSDE分别为(7.96±1.83)和(12.83±2.52)mGy ( t=-8.417,P =0.000);B组分别为(9.28±1.76)和(13.62±2.18)mGy(t=-15.051,P=0.000);C组分别为(12.19±3.65)和(15.39±3.47)mGy(t=-4.535,P=0.000)。此外,3组SSDE分别较CTDIvol平均增加了62.83%、 47.80%和28.40%,即CTDIvol过低估算被检者的辐射剂量,且随着体重指数的增加,CTDIvol与SSDE之间的差值越小。结论 SSDE能够反映特定体型的被检者进行腹部CT扫描时所接受的辐射剂量。  相似文献   

10.
目的 了解儿童CT检查扫描条件选择及其所致辐射剂量的相关性,以期通过适当调节mAs、扫描长度等参数,降低儿童CT检查患者受照剂量。方法 比较江苏省7家医院不同年龄组(<1岁、1~5岁、6~10岁和11~15岁)儿童头颅、胸部、腹部多排螺旋CT检查主要扫描参数的差异。选用相同的检查参数在TM160剂量模体上测量CTDI100,计算DLP,并通过经验加权因子,估算出不同部位检查的有效剂量(E)。对mAs、扫描长度和DLP进行多元线性回归分析,比较两家典型医院由于选择扫描条件不同所导致的剂量差异。结果 儿童头颅、胸部、腹部CT检查所致患者的有效剂量均值分别为2.46、5.69、11.86 mSv,各部位检查DLP与mAs、扫描长度均呈正相关(r=0.81、0.81、0.92,P<0.05)。较高的mAs选择,致使本研究各年龄组儿童胸腹部CT检查有效剂量是德国Galanski等研究的1.2~3.0倍;B医院各年龄组腹部检查选择了较高的扫描长度,以致其所致有效剂量均高于本研究均值。结论 建议通过合理优化儿童不同部位CT检查mAs、扫描长度等扫描参数,降低受检者所受辐射风险。  相似文献   

11.
Objective Metuximab is a specific monoclonal antibody F(ab')fragment targeted to the hepatocellular carcinoma(HCC)associated antigen of HAb18G/CD147.131I labeled metuximab has shown to be effective response on HCC in phase Ⅰ/Ⅱtrails.To evaluate the feasibility of 131I-metuximab combined with transarterial chemoembolization(TACE)is the treatment of HCC,the anthors estimated the radiation absorbed dose to organs.Methods 131I-metuximab(27.75 MBq/kg)and the mixture of anticancer drug and Lipiodol with interval 20 min later were administered to 21 patients with HCC via a transfemoral catheter.The pharmacokinetie and desimetric data were collected by means of venous blood samples.urine collections,and 4 or 5 γ-scintigraphies (SPECT) over7 d.The total amount of activity in percent of iniected activity (%ID)of main organ and the total body were calculated by regions of interest(ROI).The cumulated activities were determined from integration of the time-%ID curves using the SPSS 12.0 software.Absorbed doses to organ and red marrow were estimated according to the medical internal radiation dose (MIRD) formalism and blood-based marrow estimation with a red marrow-to-blood activity concentration ratio.The tumorto-no tumor ratio was calculated as well.Results A mean administered aetivity was 1.89 GBq per session (range 1.47-2.23 GBq).SPECT scans showed the significant accumulation of the radioconjugate in liver tumor and faint uptake in other organs until 14 d.Organ absorbed dose(n=12):the total absorbed dose to liver,spleen,thyroid,lungs,kidney and total-body was(3.19±1.01),(3.65±2.41),(3.61±2.40),(0.97±0.23),(0.96±0.35)and(0.57±1.55)Gy,with(0.55±0.09)Gy to the red marrow(n=7),respectively.From 2.88±1.11 to 1.64±0.39 were observed in tumor-to-liver ratio at 3 h to 168 h.Conclusion Internal absorbed dose estimation based on MIRD formalism is not only to establish reliable dose-response relationships for target tissue and dose-toxicity relationships for normal tissue but also to improve treatment planning in individual patient.  相似文献   

12.
幼猪头颅低剂量螺旋CT扫描参数优化研究   总被引:1,自引:0,他引:1  
Objective To optimize the scanning parameters for CT with lower radiation dose on the infant pigs' brain which mimic the baby's head of human being. Methods Five pigs underwent CT scan using regular X-ray dose I. E. , 400 mAs, and other dose including 300,250, 200,150 and 100 mAs respectively, and the other parameters were the same. Each pig was scanned 12 times repeatedly with each of the six X-ray doses, which obtained 960 image. Anatomic details and the confidence level in reaching a diagnosis were evaluated by three radiologists respectively in a double-blinded manner using a 4-point scoring system. The CTDI of every group were compared. All Results were analyzed by Chi-square test and analysis of variance. Results The CTDI of 400,300,250,200,150,100 mAs was (55.5±0.1),(41.9±0.0), (34.7±0.0), (27.8±0.0), (20.9±0.0), (12.2±0.0) mGy respectively, there was a significant difference(F = 214872.0,P < 0.05)among the six groups. There was no significant difference in the quality of images obtained from the conventional 400 mAs scanning and low dose group of 300,250,200, 150 mAs scanning images, the total score was (3.7±0.5), (3.7±0.5), (3.6±0.3), (3.6±0.5), (3.6±0.5) respectively,which was more than 3 points, while the 100 mAs group showed low quality (2.1±0.5) which was less than 3 points. In the 100 mAs group, there were 215 in 960 images >3 points, 745 images < 3 points, and regular doses of 400 mAs group (934 image > 3 points). Image quality difference was statistically significant (χ2=3289.9,P <0.05). Conclusion The low-dose scanning (120 kV, 150 mAs, 20.8 mGy)would be practical in diagnosing in normal infant pigs' brain.  相似文献   

13.
目的:评估不同的参数自动优化(AOP)曝光模式对乳腺数字化放射成像(DR)图像质量和平均腺体剂量的影响,为乳腺DR摄影的质量及剂量控制提供参考.方法:选用AOP提供的剂量(DOSE)模式、标准(STD)模式和对比度(CNT)模式三种曝光模式对乳腺模体进行曝光,每种曝光模式重复4次,记录每次曝光的平均腺体剂量(AGD).然后由两位资深的乳腺影像诊断医师分别在同一乳腺图像工作站的5MP显示器上观察,独立对所获得的12幅乳腺模体图像按美国放射学会(ACR)推荐方法评分.所有曝光数据和评分数据进行统计学分析.结果:在相同压力和乳腺厚度条件下,DOSE曝光模式的AGD最低,STD、CNT曝光模式下的AGD较之分别增加了21.9%、146.2%;3组12幅图像质量均通过ACR评分,3组图像数据分析差异无统计学意义(P>0.05).结论:乳腺DR的AOP曝光模式选择中,CNT模式的AGD明显增高.应警慎使用,DOSE模式能有效降低AGD,并且对图像质量无明显影响.  相似文献   

14.
乳腺摄影降低辐射量的优化选择   总被引:1,自引:0,他引:1  
目的:研究乳腺X线摄影中降低射线剂量曝光条件的优化选择.方法:在全自动(kV和mAs均自动,即auto filter)和半自动(手动kV、mAs自动,即auto time)曝光模式下对不同厚度的模体进行曝光,对所得照片影像质量进行评分,并测其剂量.结果:同一厚度模体在不同曝光务件下所得照片影像质量差异无显著性意义,不同厚度模体在autofilter模式下所得照片影像质量差异无显著性意义,即自动曝光控制(automatic exposure contol,AEC)装置工作状态正常.在各种曝光条件组合中,kV高的曝光条件组合X线摄影剂量低;auto filter模式下X线摄影剂量均不是最低的.结论:在乳腺X线摄影的实际工作中,首先应确保AEC的正常工作状态;在不影响照片影像质量的情况下,选用AEC装置的autotime模式适当提高kV,降低摄影剂量.  相似文献   

15.
Jacob K  Vivian G  Steel JR 《Clinical radiology》2004,59(10):928-34; discussion 926-7
AIM: To study knowledge of radiation exposure among doctors of various grades and specialties in a large district general hospital. METHODS: A multiple-choice format questionnaire with a total of 11 questions was distributed amongst doctors at Derriford Hospital, Plymouth, UK. Doctors of various grades and specialties completed 240 questionnaires which tested knowledge of terrestrial and medical radiation exposure. RESULTS: With a pass mark of only 45% and a generous marking scheme, only 66 (27.5%) doctors passed. Only 15.4-25.8% of doctors knew the doses relative to a chest radiograph of various more complex procedures involving ionizing radiation and only 12.5% of doctors were aware of the one in 2000 risk of induction of fatal carcinoma from CT of the abdomen. Only 56.7% of practitioners who, under Ionizing Radiation (Medical Exposures) Regulations 2000, have responsibility for justifying procedures, passed the test. The proportion of practitioners correctly identifying the relative dose of a test to a chest radiograph varied from 30 to 56.7%, depending on the exam type. Only 20% in this group were aware of the risk of inducing a fatal cancer from a CT of the abdomen. CONCLUSION: The study demonstrated an urgent need to improve knowledge of radiation exposure amongst doctors in clinical practice.  相似文献   

16.
Abdominal spiral CT in children: which radiation exposure is required?   总被引:1,自引:0,他引:1  
We decided to test to what extent dose reduction is possible in abdominal spiral computed tomography (CT) in young children without loss of anatomic diagnostic information. A retrospective study was performed of 30 abdominal CT examinations of children aged 3 months to 7 years. These were divided into two groups: group A with reduced radiation exposure (tube current 50 mA, CT dose index CTDIFDA < or =0.83 mGy) and group B with standard radiation exposure (tube current > or =100 mA, CTDIFDA > or =1.66 mGy). Image quality was assessed using a four-part scale ('excellent', 'good', 'sufficient', 'poor') on visual image impression and visibility of 32 anatomical details. Five experienced radiologists read the CT scans independently who were blinded to the examination parameters. Differences in ranked data were evaluated with Wilcoxon's rank sum test. No difference between groups A and B was observed in visual image impression. Detail visibility was significantly lower in group A, but the differences were limited to right upper quadrant structures (portal vein, common bile duct, pancreatic head, adrenals) and to arterial branches. Significant differences in visibility rated as 'poor' were only found for the hepatic, splenic and renal arteries; all other structures showed no difference between groups A and B. A protocol with reduced radiation exposure (50 mA, CTDIFDA < or =0.83 mGy) allowed the demonstration of most anatomic structures in abdominal spiral CT in young children. For the precise demonstration of small details (e.g. structures of the right upper quadrant), a protocol with standard radiation exposure (> or =100 mAs) was superior.  相似文献   

17.
目的:评估X-CARE技术在女性胸部CT检查中的应用价值.方法:将体检人群中行胸部CT检查的130例女性受检者随机等分为对照组和实验组,对照组采用常规低剂量螺旋CT扫描(100 kV、40 mAs),实验组采用相同条件并同时使用X-CARE技术.测量两组图像肺尖层面左侧胸大肌、隆突层面降主动脉及左心房的平均CT值、噪声(SD),计算信噪比(SNR)与对比噪声比(CNR).两名放射科医师采用5分制对图像质量进行评价,并将结果进行比较;计算并比较两组CT容积剂量指数(CTDIvol)、剂量长度乘积(DLP)及有效剂量(ED).结果:两组图像质量均能完全满足临床诊断需求,两名医师对图像质量的评估具有较好一致性(Kappa=0.775).对照组和实验组肺尖层面左侧胸大肌、隆突层面降主动脉、左心房的平均CT值分别为(64.10±9.73)、(40.33士5.52)、(39.49士5.04)HU和(60.06士11.30)、(40.05±5.88)和(39.43士5.24)HU;两组SD分别为(11.99±3.23)、(8.04士2.21)、(7.95±2.18)和(10.43±2.90)、(8.20士1.86)、(8.24±1.97);SNR分别为(5.64±1.38)、(5.37±1.57)、(5.29±1.49)和(6.06±1.73)、(5.13±1.36)、(5.04±1.35);CNR分别为(2.12士1.07)和(1.48±0.81),两组间差异均无统计学意义(P均>o.05).结论:采用X-CARE技术进行女性胸部CT检查能在减少女性乳腺受到直接辐射的同时保证很好的图像质量,具有很高的临床应用价值.  相似文献   

18.
目的为了评估飞行高度与纬度对民航机组人员飞行中所受电离辐射剂量水平的影响。方法在北纬20°-61°的不同航线的11个机场上空以RSS-111高压电离室测量宇宙辐射电离成分的剂量率。结果宇宙辐射电离成分剂量率随飞行高度的增加而呈指数型增大,并随纬度增大而增加;在同一飞行高度,随地磁纬度的增大而呈直线。增加。根据所测数据,许算出我国空域不同经纬度地区上空不同飞行高度分配层的宇宙辐射电离成分剂量率。结论在民航现有航线(从北纬61°到南纬40°)上,按现有的飞行高度分配层(一般在12km以下)飞行,机组人员每年飞行1000h所接受的宇宙辐射剂量要小于国际放射防护委员会(ICRP)建议的20mSv/a(5年平均值)剂量限值。  相似文献   

19.
目的 探讨数字乳腺X线摄影中应用不同附加滤过对辐射剂量和影像质量的影响.方法 设备采用数字乳腺机、配套的后处理工作站和5M高分辨率医用显示器.首先采用自动曝光模式对Fluke NA 18-220模体中含有模拟钙化群、纤维及块状物的蜡块和不同厚度的BR12模体(总厚度分别为1.6、2.6、3.6、4.6、5.6、6.6、7.6和8.6 cm)进行曝光,然后采用与自动曝光模式相同的管电压、管电流、压力、压迫厚度、阳极靶面及不同附加滤过板依次对不同厚度的模体进行手动曝光.记录2种曝光模式下,采用钼(molybdenum,Mo)和铑(rhodium,Rh)附加滤过板获得的平均腺体剂量(average glandular dose,AGD)、表面入射剂量(entrance surface dose,ESD)、信噪比(signal-to-noise ratio,SNR)、对比噪声比(contrast-to-noise ratio,CNR)和美国放射学院(American College of Radiology,ACR)标准的影像评分等参数值,并对Mo和Rh两组的上述参数值及AGD、ESD随模体厚度增加的增幅值进行配对样本t检验.结果 Mo、Rh滤过两组中AGD和ESD均随模体厚度的增加而增高.Rh滤过组中AGD、ESD的增幅值分别为0.423±0.190和3.057±2.139,低于Mo滤过组的0.539±0.246和4.731±3.294,差异有统计学意义(t值分别为3.396和3.605,P值均<0.05).Mo滤过组的AGD和ESD分别为1.915±1.301和12.516±11.632,Rh滤过组分别为1.484±1.041和7.969±7.633,差异均有统计学意义(t值分别为4.614和3.209,P值均<0.05).两组的SNR、CNR及影像评分值均随着模体厚度的增加而降低,差异均无统计学意义(P值均>0.05).结论 对于同一被照体,采用相同的摄影条件时,Rh滤过板相对于Mo滤过板可显著降低辐射剂量,且影像质量没有明显差别;同时随着被照体厚度的增加这种优势更加明显.  相似文献   

20.
目的 对比研究DR与CR双面阅读成像系统辐射剂量与成像质量的关系.方法 在相同的辐射剂量下用DR和CR双面阅读成像系统对ALVIM统计学摄影模体TRG进行曝光,记录摄影条件和模体表面入射剂量,然后固定此摄影条件kV值,选用不同mAs值(分别为3.2、4.0、4.3、4.8和5.2 mAs)用CR双面阅读成像系统对模体进行曝光,记录表面入射剂量,并将所获取的影像在图像诊断工作站显示器上由3名影像医师进行视读打分,按照5分值判断法评判,绘制ROC曲线,计算每种信号的判断概率值(Pdet),对不同摄影系统及条件下3名观察者对模体影像信息的判断概率平均值采用双因素方差分析(ANOVA)进行比较.结果 在辐射剂量为137.5 μGy时,DR所摄取模体影像内容物中0.5 ~ 1.0 nun直径骨代替物和0.9 ~ 2.0 mm直径肌肉代替物的Pdet值分别是0.742~0.923和0.635 ~0.900,CR双面阅读成像系统所得模体影像内容物中上述直径的骨代替物和肌肉代替物的Pdet值分别是0.526 ~0.586和0.473 ~0.560;DR和CR双面阅读成像系统对不同直径的骨替代物ROC曲线Pdet相差为0.216 ~0.337,以直径1.0mm为著,相差0.337;二者对直径0.9~2.0mm的肌肉替代物相差为0.075 ~0.342,以直径2.0mm为著,相差0.342,差异有统计学意义(F =35.30,P<0.01).当CR双面阅读系统的摄影条件增为75 kV、4.8 mAs时,辐射剂量为180.4μGy,两种摄影系统所摄取影像ROC曲线的Pdet值基本相同,二者对直径0.5~1.0 mm骨代替物ROC曲线的Pdet相差为-0.003 ~0.009;二者对直径0.9 ~2.0 mm肌肉代替物ROC曲线的Pdet 相差为~0.005 ~0.008,差异无统计学意义(F=5.23,P>0.05).在相同的判断概率值Pdet下,CR双面阅读成像系统所用表面入射剂量为180.4 μGy,DR所用的表面入射剂量为137.5 μGy.结论 在相同曝光条件下,DR对模体内容物的检出率高于CR双面成像系统;在获得相似图像质量时,DR的辐射剂量低于CR双面阅读成像系统.  相似文献   