首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The relative efficacies of different spin-echo pulse sequences at 1.5 T were evaluated in the detection of focal hepatic disease. Pulse sequences compared were spin-echo with a repetition time (TR) of 200 msec and echo time (TE) of 20 msec, with six excitations; TR = 300 msec, TE = 20 msec, with 16 excitations (T1-weighted sequences); and a double spin-echo with TR = 2500 and TE = 25 and 70, with two excitations (proton-density-weighted and T2-weighted pulse sequences, respectively). Respiratory-motion compensation, which involved a recording of the phase-encoding gradients (Exorcist), was used for the last two sequences. Spin-echo with TR = 2500 msec and TE = 70 msec was superior in lesion detection and contrast-to-noise ratio. The proton-density-weighted and T2-weighted sequences with respiratory compensation produced better artifact suppression than did the short TR, short TE T1-weighted sequence with temporal averaging. In contradistinction to prior results at 0.6 T, T2-weighted pulse sequences appear superior to T1-weighted pulse sequences with multiple excitations for both lesion detection and artifact suppression at 1.5 T.  相似文献   

2.
We studied the efficacy of T2 measurements at high field strength in distinguishing between liver hemangiomas and hepatic metastases when an ultrafast (single-excitation) MR imaging technique is used. Fourteen patients with known liver tumors were imaged in a 2.0-T prototype ultrafast MR scanner with a spin-echo (infinite TR and TE of 30-340 msec) pulse sequence. Each image was obtained with a total data acquisition time of 20 msec. T2 calculations for hepatic metastases (n = 6) showed a mean of 79.3 +/- 13.5 msec, whereas hemangiomas (n = 8) showed a T2 of 139.8 +/- 18.8 msec (p less than .0001). T2 values of lesions had a smaller relative standard deviation than previously reported, and the range of T2 values of hemangiomas (119-181 msec) and metastases (68-103 msec) did not overlap. Our preliminary results suggest that T2 calculations with ultrafast MR imaging may be useful for differentiating hemangiomas from metastases. We hypothesize that T2 values obtained from ultrafast MR images are more reliable than those obtained from conventional MR images, primarily because of the elimination of T1 information and effects of motion on image signal intensity.  相似文献   

3.
Stark  DD; Wittenberg  J; Butch  RJ; Ferrucci  JT  Jr 《Radiology》1987,165(2):399-406
To determine the accuracy of magnetic resonance (MR) imaging relative to computed tomography (CT) in the diagnosis of liver metastases, a randomized, controlled study was conducted of 135 subjects, including 57 with cancer metastatic to the liver, 27 with benign cysts or hemangiomas, and 51 without focal liver disease. The sensitivity of MR imaging for detecting individual metastatic deposits was 64%, significantly greater than 51% for CT (P less than .001); the difference in sensitivity for identifying patients with one or more hepatic metastases was less (82% for MR imaging vs. 80% for CT). In patients without hepatic metastases, the specificity of MR imaging was 99% versus 94% for CT. Significant differences were found between individual MR pulse sequences in detection of individual lesions. The sensitivity of both T1-weighted spin-echo (SE) (64%) and inversion-recovery (IR) (65%) pulse sequences was significantly (P less than .001) greater than either the TE (echo time) 60 msec (43%) or TE 120 msec (43%) T2-weighted pulse sequences. Overall, the accuracy of a single T1-weighted (10-minute) pulse sequence was superior to that of contrast-enhanced CT.  相似文献   

4.
An animal model of liver cancer was used to demonstrate that with a fast MRI technique, Gadolinium-DTPA increases tumor-liver contrast. A spin-echo pulse sequence with short repetition (TR) and echo-delay (TE) times (TR 250/TE 15/Excitations 1) has a scan time of 0.6 min, which allows early dynamic postcontrast infusion imaging. This is necessary to capture peak compartmental differences when an extracellular contrast agent such as Gadolinium-DTPA is used. This short TR/short TE pulse sequence also increases T1-dependent tissue contrast over the traditional (inversion recovery or spin echo) T1-weighted pulse sequences. Our studies suggest a significant potential for improved detection of liver metastases with Gadolinium-DTPA-enhanced liver MRI.  相似文献   

5.
Hepatic metastases studied with MR and CT   总被引:1,自引:0,他引:1  
Heiken  JP; Lee  JK; Glazer  HS; Ling  D 《Radiology》1985,156(2):423-427
Examinations of the liver using magnetic resonance (MR) and computed tomography (CT) were performed on 50 patients with hepatic metastases. MR and CT were comparable in their ability to detect metastases, which generally appeared hypointense compared with normal liver parenchyma on T1-weighted MR images and hyperintense on T2-weighted images. The MR imaging techniques that were most reliable in detecting metastases were inversion recovery and a relatively T2-weighted, spin-echo technique (TR = 1,500 msec, TE = 60 msec). We conclude that CT, because of its shorter imaging time, greater spatial resolution, and lower cost, should remain the preferred screening test for hepatic metastases. MR imaging should be reserved for patients with equivocal CT findings and for patients in whom there is persistent clinical suspicion of hepatic metastases despite a negative CT examination.  相似文献   

6.
The role of magnetic resonance (MR) imaging in the detection of gallbladder disease was evaluated in 39 individuals (16 healthy, five with asymptomatic gallstones, and 18 with clinical symptoms of gallbladder disease). MR imaging was performed after they fasted for 12 hours. Imaging sequences included a combination of repetition times (TR) of 0.5 and 1.5 sec and echo times (TE) of 28 and 56 msec. On the images obtained at TR = 0.5 sec and TE = 56 msec, gallbladder bile was hyperintense compared with the liver in all healthy and asymptomatic subjects and was hypointense (n = 9), isointense (n = 4), or hyperintense (n = 5) in symptomatic patients, eight of whom had surgical confirmation of cholecystitis. Comparison of normal versus pathologically proved cases for the presence of gallbladder disease yielded a specificity of 100%, sensitivity of 75%, and a significant difference of P less than .01. Thus, with a pulse sequence of TR = 0.5 sec and TE = 56 msec, MR was sensitive in detecting gallbladder disease. However, the role of MR in the radiologic workup of gallbladder disease will be determined by more experience with this modality.  相似文献   

7.
Conventional and rapid MR imaging of the liver with Gd-DTPA   总被引:1,自引:0,他引:1  
Hamm  B; Wolf  KJ; Felix  R 《Radiology》1987,164(2):313-320
Twenty-three patients with malignant hepatic tumors underwent magnetic resonance (MR) imaging before and after intravenous administration of gadolinium-diethylene-triaminepentaacetic acid (DTPA). Two different doses were used, 0.1 mmol/kg and 0.2 mmol/kg. The larger dose proved to be more effective than the smaller dose. The signal-enhancement-to-noise ratio was significantly larger in the tumor than in the liver (2 alpha less than or equal to .05). In a moderately T1-weighted spin echo (SE) sequence (SE 400/30) (repetition time [TR] msec/echo time [TE] msec), the tumor was better defined 6 minutes after administration of Gd-DTPA. More strongly T1-weighted sequences--that is, SE 200/20 and inversion recovery 1,500/35/400 (TR msec/TE msec/inversion time, msec)--showed significantly worse contrast between tumor and liver (signal-difference-to-noise ratio [SD/N]) 10 and 15 minutes after administration (2 alpha less than or equal to .05). On the other hand, the low SD/N in the rapid MR imaging sequence was significantly improved (2 alpha less than or equal to .05). The most important indications for administration of Gd-DTPA in diagnosing hepatic tumors are the presentation of perfusion conditions and contrast optimization in rapid MR images.  相似文献   

8.
Glazer  GM; Aisen  AM; Francis  IR; Gyves  JW; Lande  I; Adler  DD 《Radiology》1985,155(2):417-420
Using a 0.35-T superconducting magnet and spin echo imaging, we prospectively evaluated 11 patients who had proved hepatic cavernous hemangioma. Magnetic resonance (MR) identified more lesions than either contrast-enhanced CT, or ultrasonography. The MR appearance was consistent; hemangiomas were homogeneous and generally isointense at short TR and TE intervals but were hyperintense at long TR intervals and greatly hyperintense at long TR and long TE intervals. However, the MR appearance of hemangioma was not specific; 2/14 other focal hepatic masses had similar features. The calculated relaxation times (T1, T2) were not useful in lesion characterization, although the intensity ratio of hemangioma to normal liver at the TR = 2.0 sec TE = 56 msec pulse sequence was useful in diagnosis since hemangiomas always had a ratio greater than 1.4.  相似文献   

9.
Magnitude-reconstructed short inversion-time (TI) inversion-recovery (IR) sequences have the advantage of reducing the signal of fat while providing additive T1 and T2 contrast. A double-echo short TI IR sequence was implemented to offer different degrees of T1- and T2-dependent image contrast. In 50 consecutive patients with proved liver tumors (30 metastases, 13 hemangiomas, seven other primary liver tumors), images obtained with a double-echo IR sequence at a repetition time (TR) of 1,500 msec, echo time (TE) of 30 and 60 msec, and TI of 80 msec (TR/TE/TI = 1,500/30, 60/80) were compared with those obtained with spin-echo (SE) sequences at a TR of 275 msec and a TE of 14 msec (TR/TE = 275/14) and 2,350/60, 120, 180. Metastases-liver contrast-to-noise ratios were highest at SE 275/14, followed by IR 1,500/30/80 and SE 2,350/180. IR 1,500/30/80 and SE 275/14 sequences consistently showed higher sensitivity for the detection of metastases than T2-weighted SE sequences. Differential diagnosis of benign and malignant lesions was more reliable with T2-weighted SE sequences than T2-weighted short TI IR sequences.  相似文献   

10.
To find an optimal magnetic resonance (MR) sequence for mangafodipir trisodium-enhanced liver and pancreas imaging, six healthy volunteers were studied using a 1.5 T MR system with different T1-weighted abdominal imaging sequences. These were turbo field (gradient)-echo (TFE), fast field (gradient)-echo (FFE), and spin-echo sequences before and after mangafodipir trisodium administration. Various parameter combinations were investigated within each sequence type, and then the best combination was found and compared with those of the other sequences. Signal intensity (SI) measurements were made in regions of interest in the liver, pancreas, and a reference marker with a known T1 value. Contrast index (CI, SItissue/SImarker) and contrast-to-noise ratio (CNR, [SItissue/SImarker]/SDbackground) were calculated, and percentage CI increase and CNR in the postcontrast images were used for the best sequence evaluation. Regarding CI, the TFE sequence with a TR/TE/flip angle of 15 msec/4.6 msec/20 degrees and inversion time of 300 msec had the largest pre- to postcontrast percentage increase. The FFE sequence with a TR/TE/flip angle of 140 msec/4.6 msec/90 degrees had the highest postcontrast CNR and is considered to be the optimal sequence for mangafodipir trisodium-enhanced MR imaging of the liver and pancreas.  相似文献   

11.
Forty-three patients with liver metastases were imaged using 14 different pulse sequences (average, 7.5 sequences per patient) to allow direct comparison of their performance. "T2-weighted" spin-echo (SE) images, "T1-weighted" inversion recovery (IR) images, and "T1-weighted" SE images were obtained using a wide range of timing parameters. Pulse sequence performance was quantitated by measuring liver signal-to-noise (S/N) ratios and cancer-liver signal difference-to-noise (SD/N) ratios. Data were standardized to reflect a constant imaging time of 9 minutes for all pulse sequences. The SE 2,000/120 (TR [repetition time]/TE [echo time]) sequence resulted in the greatest SD/N ratio of the T2-weighted SE sequences but also yielded the low S/N ratios, poor anatomic resolution, and motion artifacts common to all T2-weighted SE images. IR sequence images were also sensitive to motion artifacts because of the use of a long TR (1,500 msec). Short TR/TE T1-weighted SE sequences (SE 260/18) had the greatest SD/N ratio (P less than .05), S/N ratio, and anatomic resolution. Furthermore, extensive signal averaging appears to be a powerful solution to all types of motion artifacts in the abdomen.  相似文献   

12.
Imaging of pancreatic neoplasms: comparison of MR and CT   总被引:2,自引:0,他引:2  
Thirty-two patients with pathologically proved pancreatic carcinomas or cystadenomas were evaluated with MR images obtained with T1-weighted spin echo (short TR/short TE), inversion recovery, and T2-weighted spin-echo (long TR/long TE) pulse sequences. CT was used as the reference standard to determine the ability of MR to delineate normal and abnormal pancreatic anatomy and thereby to exclude or detect pancreatic malignancy. Short TR/short TE spin-echo sequences were significantly better (p less than .05) than inversion recovery or T2-weighted spin-echo sequences in resolution of both normal and abnormal anatomy. Resolution of pancreatic anatomy correlated (r = .9) with the image signal-to-noise ratio. In seven (22%) of 32 cases, MR visualized pancreatic tumors better than CT did because it showed a signal intensity difference between the tumor and normal pancreatic tissue. Overall, the slight superiority of MR over CT for tumor visualization tended to occur in larger tumors and was not statistically significant. On T1-weighted images, 63% (20 of 32) of pancreatic tumors studied had lower signal intensities than normal pancreatic tissue, whereas on T2-weighted sequences (TE = 60, 120, and 180 msec) only 41% (13 of 32) of tumors had increased signal intensities. Currently available MR imaging techniques offer no significant advantages over CT for evaluating the pancreas for neoplasia.  相似文献   

13.
The magnetic resonance (MR) examinations of 18 patients with dilated bile ducts were reviewed retrospectively to determine the capability of MR to demonstrate biliary dilatation, assess MR appearance of the dilated biliary tract using spin-echo techniques, and define the optimal MR imaging parameters (repetition time [TR] and echo time [TE]) for its demonstration. On images with short TR (0.5 sec) and TE (28 msec), the dilated intrahepatic and intrapancreatic bile ducts usually had lower signal intensity compared with the surrounding liver or pancreas; on images with long TR (2.0 sec) and TE (56 msec), they had higher signal intensity. Because of the observed variation in percentage of contrast between dilated bile ducts and surrounding liver and pancreas, two imaging sequences are recommended to obtain reliable demonstration of dilated intrahepatic and intrapancreatic bile ducts. The dilated common bile duct at the level of the hepatic hilus is best seen with a short TR and TE.  相似文献   

14.
PURPOSE: To develop a technique for time-efficient multislice double inversion-recovery (DIR) black-blood imaging and to test its applicability and limitations for high-resolution imaging of carotid arteries. MATERIALS AND METHODS: A multislice DIR pulse sequence with fast spin-echo (FSE) readout was implemented on a 1.5 T magnetic resonance (MR) scanner. The principle of the method is that a slice-selective inversion in a DIR preparation reinverts an entire slice pack, and all slices are imaged within repetition time (TR). The number of slices acquired per TR (N) controls the inversion time (TI) to execute the readout for each slice at the zero-crossing point of blood. Multislice DIR images (TR/TE = 2500/9 msec) of carotid arteries were obtained with variable N = 2-8 from four subjects. The method was compared with the standard single-slice DIR and inflow saturation techniques. RESULTS: Multislice DIR with N = 2-6 provided similar flow suppression in carotid arteries as single-slice DIR. At all N = 1-8, blood suppression by DIR was significantly better than by inflow saturation. An additional limitation of multislice DIR was saturation of the signal from stationary tissues that worsened visualization of the vessel wall at N >or= 6. CONCLUSION: Multislice DIR provides up to eight-fold improvement of time-efficiency relative to single-slice DIR and high-quality blood suppression.  相似文献   

15.
Use of intraacquisition modification of pulse-sequence parameters to reduce acquisition time for conventional T2-weighted spin-echo images was evaluated. With this technique (variable-rate spin-echo pulse sequence), the repetition time and echo time (TR msec/TE msec) were reduced during imaging as a function of the phase-encoding view. To maintain T2-based contrast, TR and TE for the low-spatial-frequency views were left at their prescribed values (eg, 2,000/80). TR and TE for the high-spatial-frequency views were progressively reduced during imaging (eg, to 1,000/20). Acquisition time was reduced by as much as 25%. In one pulse sequence, the duration of multisection imaging nominally performed at TR 2,000 and with 256 phase-encoding views was reduced from 9 minutes 30 seconds to 6 minutes 30 seconds. In all sequences, edges and small structures were enhanced, and T2 contrast was somewhat decreased in high spatial frequencies. Filtering of the raw data before reconstruction can suppress these effects and provide a net increase in contrast-to-noise ratio.  相似文献   

16.
MR of visual pathways in patients with neurofibromatosis   总被引:1,自引:0,他引:1  
MR was performed on six patients clinically diagnosed as having neurofibromatosis. Owing to its multiplanar capability, MR greatly helped determine the extent of visual pathway disease. We attempted to find specific optimal pulse sequences for evaluating the prechiasmatic, chiasmatic, and retrochiasmatic visual system at 0.35 T. Using spin-echo techniques, we evaluated a T1-weighted sequence (TR 300 msec/TE 35 msec), an intermediate T2-weighted sequence (TR 1500 msec/TE 35 msec), and a T2-weighted sequence (TR 1500 msec/TR 70 msec). We found that the orbital and intracanalicular optic nerves were most accurately and easily seen with the T1-weighted sequence axially and coronally; the chiasm was best seen with the intermediate T2-weighted coronal sequence; and the retrochiasmatic visual pathway was optimally evaluated with T2-weighted spin-echo technique.  相似文献   

17.
Adrenal tissue characterization using MR imaging   总被引:3,自引:0,他引:3  
Using a superconducting magnet operating at 0.35 T, the authors investigated the adrenal tissue characterization potential of magnetic resonance (MR) in 28 patients with 33 adrenal masses. There were 13 adrenal adenomas (12 non-hyperfunctioning, one aldosteronoma), nine adrenal metastases, four pheochromocytomas, two neuroblastomas, two adrenal lymphomas, two myelolipomas, and one adrenal cortical carcinoma. Spin-echo pulse sequences were obtained at TR 0.5, 2.0 sec and TE 28, 56 msec. Both qualitative (visual assessment) and quantitative (absolute signal intensity, intensity ratios, T1, T2) data were used for tissue characterization. The results suggest that non-hyperfunctioning adrenal adenomas can be distinguished from non-adenomas using both qualitative and quantitative data: 16/19 non-adenomas were visually hyperintense compared with liver at TR 2.0 sec, TE 56 msec, while none of the non-hyperfunctioning adenomas was relatively hyperintense at any pulse sequence used. Of the quantitative data, the intensity ratios of adrenal lesion/liver at TR 0.5 sec, TE 56 msec were most useful in diagnosis: all adenomas had ratios less than 0.83, while 19/20 non-adenomas had ratios exceeding this value. It is concluded that MR has considerable promise in adrenal tissue characterization.  相似文献   

18.
This paper deals with a study to obtain the optimal sequence of gradient echo (GE) for T1- and T2*-weighted images similar to T1- and T2-weighted images of spin echo (SE). Two GE sequences, fast low angle shot (FLASH) and fast imaging with steady-state precession (FISP), were performed in 15 cases of liver metastasis in various combination of flip angle (FA), repetition time (TR), and echo time (TE). The optimal combinations were summarized as follows: 1) T1-weighted FLASH image with FA of 40 degrees, TR of 22 msec and TE of 10 msec, 2) T1-weighted FISP image with FA of 70 degrees, TR of 100 msec, TE of 10 msec, 3) both T2*-weighted FLASH and FISP images with FA of 10 degrees, TR of 100 msec and TE of 30 msec. Not only to provide the adequate T1- and T2*-weighted images but also to enable breath-holding MR imaging, GE sequences can optionally take place SE in cases of deteriorated images caused by moving artifacts. Other applications support the re-examination and further detailing when required, conveniently rather in short time.  相似文献   

19.
Combined gadolinium-enhanced and fat-saturation MR imaging of renal masses   总被引:4,自引:0,他引:4  
Combined gadopentetate dimeglumine enhancement and fat-saturation (FS) spin-echo (SE) magnetic resonance (MR) imaging for the detection and characterization of renal masses was evaluated in 43 patients with a total of 71 lesions (28 solid masses and 43 cysts). SE MR sequences compared were the following: short repetition time (TR)/echo time (TE), conventional SE, short TR/TE FS SE, long TR/TE conventional SE, gadolinium-enhanced short TR/TE conventional SE, and gadolinium-enhanced short TR/TE FS SE techniques. MR findings were compared with findings of contrast-enhanced computed tomography (CT) and with pathologic findings in all patients. The sensitivities for detection of renal masses with gadolinium-enhanced FS (71 of 71 lesions) and with gadolinium-enhanced short TR/TE conventional (65 of 71 lesions) SE sequences were significantly (P less than .01) greater than with any unenhanced (short TR/TE conventional [40 of 71 lesions], or long TR/TE [39 of 71 lesions]) SE sequence. Lesion characterization was also best with the gadolinium-enhanced FS SE sequence (65 of 71 lesions correctly classified). When combined pre- and postcontrast short TR/TE FS SE images were analyzed with both qualitative (visual) and quantitative (region-of-interest measurements) assessment, lesion characterization improved even further (70 of 71 lesions were correctly characterized). All lesions detected with CT were visualized with the gadolinium-enhanced FS SE MR sequence, which in addition depicted seven cysts and two small renal cell carcinomas. In summary, the use of gadopentetate dimeglumine, especially when combined with the FS technique, was superior to unenhanced MR imaging for detection and characterization of renal lesions.  相似文献   

20.
MR studies of the lumbar spine in 111 patients were analyzed at 469 disks to assess the prevalence of intranuclear cleft (INC) in the lumbar intervertebral disk. MR studies were performed on either 0.1-tesla (T) magnet (69 patients) or 0.22-T magnet (42 patients). The pulse sequences reviewed were saturation recovery (SR; TR = 0.5 sec), short TR, TE spin echo (S-SE; TR = 0.5 sec, TE = 34 msec) and long TR, TE spin echo (L-SE; TR = 1.5 sec, TE = 68,80 msec). All study were done in a sagittal plane with 10 mm slice thickness. The conclusions were as follows: 1) On a 80 msec TE, 1.5 sec TR image, INCs were detected in more than 80% of disks in patients over 30 years old but in only 13.3% of disks in patients under 20 years old. 2) In both imaging system, L-SE showed INCs more frequently than SR and S-SE. 3) INCs were less frequently demonstrated in the disk with decreased signal intensity on 0.1-T magnet as compared with 0.22-T magnet. 4) On SR and S-SE, there is an increase in the prevalence of INC in the disk with decreased signal intensity. We suggest that the INC will be a good landmark of the pathological process of the lumbar disk, such as degeneration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号