首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
The effect of muscle tone on passive range of motion (PROM) in affected joints and comparison joints on the unaffected side was investigated in 15 patients with flaccid paralysis hemiplegia. PROM was measured in the shoulder and hip in flexion, extension, abduction, adduction and internal and external rotation using the plastic universal goniometer. PROM in the elbow and knee was assessed in flexion and extension. Wrist PROM was measured in flexion, extension and radial and ulnar deviation. Additionally, ankle dorsiflexion, plantarflexion, eversion and inversion PROM were assessed. Decreased muscle tone significantly affected shoulder (p = 0.006), wrist (p = 0.032) and hip (p = 0.003) PROM. Significant differences between the affected and unaffected sides were found in shoulder PROM in extension (p = 0.014), adduction (p = 0.001) and internal (p = 0.034) and external rotation (p = 0.007). Wrist PROM was significantly different in flexion (p = 0.048) and extension (p = 0.001), and hip PROM was significantly different in abduction (p = 0.029), adduction (p = 0.012) and external rotation (p = 0.001). Surprisingly, although muscle tone had no influence on ankle PROM, there was a significant difference in ankle plantarflexion PROM (p = 0.013). In conclusion, in flaccid hemiplegia, decreased muscle tone affects the PROM in the shoulder, wrist and hip. Differences in PROM between the unaffected and affected side are evident in shoulder extension, adduction and internal and external rotation, wrist flexion and extension, hip abduction, adduction and external rotation, and ankle plantarflexion.  相似文献   

2.
Goniometric reliability in a clinical setting. Shoulder measurements   总被引:5,自引:0,他引:5  
The purpose of this study was to examine the intratester and intertester reliabilities for clinical goniometric measurements of shoulder passive range of motion (PROM) using two different sizes of universal goniometers. Patients were measured without controlling therapist goniometric placement technique or patient position during measurements. Repeated PROM measurements of shoulder flexion, extension, abduction, shoulder horizontal abduction, horizontal adduction, lateral (external) rotation, and medial (internal) rotation were taken of two groups of 50 subjects each. The intratester intraclass correlation coefficients (ICCs) for all motions ranged from .87 to .99. The ICCs for the intertester reliability of PROM measurements of horizontal abduction, horizontal adduction, extension, and medial rotation ranged from .26 to .55. The intertester ICCs for PROM measurements of flexion, abduction, and lateral rotation ranged from .84 to .90. Goniometric PROM measurements for the shoulder appear to be highly reliable when taken by the same physical therapist, regardless of the size of the goniometer used. The degree of intertester reliability for these measurements appears to be range-of-motion specific.  相似文献   

3.
OBJECTIVES: To identify the etiology of hemiplegic shoulder pain by arthrographic and clinical examinations and to determine the correlation between arthrographic measurements and clinical findings in patients with hemiplegic shoulder pain. DESIGN: Case series. SETTING: Medical center of a 1582-bed teaching institution in Taiwan. PARTICIPANTS: Thirty-two consecutive patients with hemiplegic shoulder pain within a 1-year period after first stroke were recruited. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Clinical examinations included Brunnstrom stage, muscle spasticity distribution, presence or absence of subluxation and shoulder-hand syndrome, and passive range of motion (PROM) of the shoulder joint. Arthrographic measurements included shoulder joint volume and capsular morphology. RESULTS: Most patients had onset of hemiplegic shoulder pain less than 2 months after stroke. Adhesive capsulitis was the main cause of shoulder pain, with 50% of patients having adhesive capsulitis, 44% having shoulder subluxation, 22% having rotator cuff tears, and 16% having shoulder-hand syndrome. Patients with adhesive capsulitis showed significant restriction of passive shoulder external rotation and abduction and a higher incidence of shoulder-hand syndrome (P=.017). Those with irregular capsular margins had significantly longer shoulder pain duration and more restricted passive shoulder flexion (P=.017) and abduction (P=.020). Patients with shoulder subluxation had significantly larger PROM (flexion, P=.007; external rotation, P<.001; abduction, P=.001; internal rotation, P=.027), lower muscle tone (P=.001), and lower Brunnstrom stages of the proximal upper extremity (P=.025) and of the distal upper extremity (P=.001). Muscle spasticity of the upper extremity was slightly negatively correlated with shoulder PROM. Shoulder joint volume was moderately positively correlated with shoulder PROM. CONCLUSIONS: After investigating the hemiplegic shoulder joint through clinical and arthrographic examinations, we found that the causes of hemiplegic shoulder pain are complicated. Adhesive capsulitis was the leading cause of shoulder pain, followed by shoulder subluxation. Greater PROM of the shoulder joint, associated with larger joint volume, decreased the occurrence of adhesive capsulitis. Proper physical therapy and cautious handling of stroke patients to preserve shoulder mobility and function during early rehabilitation are important for a good outcome.  相似文献   

4.
OBJECTIVE: To determine variables among glenohumeral elevation and 3-dimensional scapular rotations that are related to shoulder function as assessed by the Disability of the Arm, Shoulder and Hand-Disability/Symptom (DASH-D/S) scale. DESIGN: Prospective, cross-sectional study. PATIENTS: Eighty-eight patients with shoulder pain and limited range of motion were included. METHODS: Each patient performed 2 full active range of motion activities, forward flexion and abduction, and 2 activities of daily living, combing hair and simulating washing the back. Glenohumeral elevation and scapular rotations were measured by the Polhemus Fastrak electromagnetic system. RESULTS: On multiple regression analysis, glenohumeral elevation in combing hair and scapular lateral rotation in both abduction and simulating washing the back were the best predictors of shoulder function and explained 39.7% of the variance of the DASH-D/S score. CONCLUSION: These findings support the classical rehabilitation of the shoulder based on glenohumeral elevation and suggest the importance of attention paid to scapular lateral rotation.  相似文献   

5.
《Manual therapy》2014,19(1):77-81
This study characterized the impairments of range of motion, three-dimensional scapulo-thoracic kinematics, isokinetic muscle performance and disability in a patient with Parsonage–Turner Syndrome. The patient had a history of 2.5-years of shoulder pain, and electroneurodiagnostic testing indicative of suprascapular neuropathy. The patient-rated Disabilities of the Arm, Shoulder and Hand (DASH) score was 33.3% (0 = no symptoms/disability), and reduced shoulder internal rotation, external rotation, and flexion as compared bilaterally. There were deficits in isokinetic muscle performance at slow and fast speeds during abduction, lateral and medial rotations as compared to the uninvolved side. Alterations in scapular kinematics were decreased posterior tilt, increased internal rotation, and increased upward rotation during arm elevation and lowering. This information can be used to assist clinicians in developing treatment programs to address the alterations caused by this neuralgic amyotrophy.  相似文献   

6.
Populations considered for shoulder analysis are often composed of various ratios of men and women. It is consequently hypothesized that gender has no significant effect on the joint kinematic. However, the literature reports, for the shoulder, differences in the range of motion between genders. The specific influence of gender on the scapulo‐thoracic kinematics has not been studied yet. The dominant shoulder of two populations of men and women composed of 11 subjects each were evaluated in three dimensions for three distinct motions: flexion in the sagittal plane, abduction in the frontal plane and gleno‐humeral internal/external rotation with the arm abducted at 90°. Posture, kinematics and range of motion were studied separately. For flexion and abduction and with regard to the scapular kinematic, external rotation was significantly larger for women than men. The differences were of at least 5° at 120° of humeral elevation. Upward rotations were identical. Women also showed larger average active humero‐thoracic range of motion. The mean differences were of 13°, 7°, 12° and 5° for abduction, flexion, internal rotation and external rotation, respectively. No difference was observed between the scapular resting positions of both populations. The observed differences concerning both the scapular and humeral patterns would indicate that the shoulder behaviour of men and women should not be expected to be similar.  相似文献   

7.
BackgroundContradictory evidence exists regarding the clinical course of frozen shoulder (FS).ObjectivesTo explore the clinical course of FS regarding disabilities, pain, range of motion (ROM), muscle strength, scapular upward rotation, and proprioception and to establish longitudinal correlations between these variables.MethodsPatients with FS were prospectively followed for 9 months at 3-month intervals. Assessment included the Disabilities of the Arm, Shoulder and Hand questionnaire; visual analogue scale for pain; an inclinometer for shoulder external rotation (ER), internal rotation (IR), flexion, and abduction ROM, and scapular upward rotation and proprioception, as well as handheld dynamometry for muscle strength in shoulder abduction, ER, and IR.ResultsInitially, 149 patients (98 females; mean (SD) age 53 (9) years) were included, with 88 completing all follow-up assessments. Most variables showed early improvement in the clinical course of FS, particularly ER and IR at 90° abduction, which continued to improve from 6 to 9 months of follow-up. Associations were observed between disabilities and pain (r = 0.61), disabilities/pain and ROM (r=-0.62 to -0.59 and r=-0.47 to -0.39, respectively), disabilities/pain and muscle strength (r=-0.24 to -0.35 and r=-0.36 to -0.17, respectively), and between disabilities/pain and scapular upward rotation below shoulder level (r = 0.23 to 0.38 and r = 0.24 to 0.30, respectively). ROM correlated with muscle strength (r = 0.14 to 0.44), while both ROM and ER muscle strength correlated with scapular upward rotation below shoulder level (r=-0.37 to -0.23 and r=-0.17 to -0.12, respectively). Muscle strength correlated with scapular upward rotation above shoulder level (r = 0.28 to 0.38) and lift-off muscle strength correlated with joint repositioning (r=-0.17 to -0.15).ConclusionAlmost all factors improved in the early phase (3–6 months) after baseline assessment, while ER and IR ROM at shoulder level continued to improve long term.  相似文献   

8.
The purpose of this study is to restore the motion of the paralyzed shoulder caused by upper motor neuron disorders using functional electrical stimulation (FES). Percutaneous wire electrodes were implanted into twelve muscles of the shoulder in six patients with stroke or cervical spinal cord injury. The motion of the paralyzed shoulder was controlled by a portable FES computer system, with the three standard stimulation patterns for restoring motion of 90 degrees flexion to 90 degrees horizontal abduction, 90 degrees flexion to 20 degrees horizontal adduction, and 90 degrees abduction to 90 degrees horizontal adduction. Shoulder movements were repeatedly controlled according to the created stimulation patterns in five of the patients. The two dimensional motion analyzer also confirmed shoulder control over a satisfactorily broad range of excursion. One hemiplegic patient, who was a signboard painter, had his paretic left upper extremity improved by FES, and he drew a large picture on a board with his normal right hand and, with his affected left arm against the wall, to support his trunk. This may be a world first case of producing shoulder motion through FES.  相似文献   

9.
ObjectiveTo better understand how the shoulder moves in breast cancer survivors with axillary web syndrome (AWS), we compared 3-dimensional (3D) shoulder kinematics during shoulder elevation among breast cancer survivors with and without AWS 5 years postoperatively. Although research consistently shows decreased shoulder range of motion with AWS, we do not understand the underlying biomechanics.DesignNested case control study.SettingUniversity Academic Breast Center.ParticipantsTwenty-five women who had surgery 5 years previously for unilateral breast cancer with the removal of at least 1 lymph node participated in this study (N=25). Twelve participants had AWS; 13 women did not have AWS.InterventionsNot applicable.Main Outcome MeasuresThree-dimensional shoulder kinematic data during shoulder forward flexion, scapular plane abduction, and coronal plane abduction were collected using 3D electromagnetic motion tracking. Kinematic data were extracted at 30°, 60°, 90°, and 120° of arm elevation for scapular upward rotation, internal rotation, and posterior tilt as well as for glenohumeral external rotation.ResultsWomen with AWS demonstrated 15.2° less scapular upward rotation at 120° humerothoracic elevation (95% confidence interval [-25.2, -5.2], P=.005), regardless of plane. No significant between-group differences were found for any other angle of scapular upward rotation, nor for scapular internal rotation, scapular posterior tilt, or glenohumeral axial rotation at any angle.ConclusionsFive years after surgery for breast cancer, women diagnosed with AWS have altered scapulohumeral kinematics that may place them at an increased risk of shoulder pain based on existing kinematic literature in healthy cohorts. This information can help guide rehabilitation programs for breast cancer survivors to facilitate pain-free upper extremity function after treatment.  相似文献   

10.
目的:观察上肢康复机器人结合常规康复训练对急性期脑卒中患者上肢运动功能的改善情况。方法:将50例脑卒中患者随机分为对照组和观察组,对照组每天进行2次常规康复训练,观察组每天进行1次常规康复训练及1次上肢康复机器人训练,每周治疗5d,共4周,治疗前后分别用Fugl-Meyer(上肢部分,FMA-UE)、改良日常生活能力(MBI)、肩关节主动关节活动度评价康复效果。结果:治疗后,2组患者的FMA-UE、肩关节主动关节活动度和MBI评估均有明显提高(P0.05),上肢康复机器人结合常规康复训练组的FMA-UE和肩关节前屈、水平内收、水平外展主动关节活动度与对照组相比提高更加明显(P0.05)。结论:上肢康复机器人结合常规康复训练对急性期脑卒中患者上肢功能有明显改善作用。  相似文献   

11.

Objectives:

To evaluate intra-rater and inter-rater reliability and measurement error in glenohumeral range of motion (ROM) measurements using a standard goniometer.

Study design:

17 adult subjects with and without shoulder pathology were evaluated for active and passive range of motion. Fifteen shoulder motions were assessed by two raters to determine reliability. The intra-class correlation coefficients (ICC) were calculated and examined to determine if reliability of ICC ≥ 0.70 existed. The standard error of measurement (SEM) and the minimal clinical difference (MCD) were also calculated.

Results:

Thxe criterion reliability was achieved in both groups for intra-rater reliability of standing AROM abduction; supine AROM and PROM abduction, flexion, external rotation at 0° abduction; and for inter-rater reliability of supine AROM and PROM abduction, external rotation at 0° abduction. The SEM ranged from 4°-7° for intra-rater and 6°-9° for inter-rater agreement on movements that achieved the criterion reliability. The MCD ranged from 11°-16° for a single evaluator and 14°-24° for two evaluators.

Conclusions:

Assessment of AROM and PROM in supine achieves superior reliability. The use of either a single or multiple raters affects the number of movements that achieved clinically meaningful reliability. Some movements consistently did not achieve the criterion and may not be the best movements to monitor treatment outcome.  相似文献   

12.
OBJECTIVE: Post-stroke shoulder pain is a common phenomenon in hemiplegia and impedes rehabilitation. The aim of this study was to identify a possible relationship between post-stroke shoulder pain, scapula resting position and shoulder motion. METHODS: Shoulder kinematics of 27 patients after stroke (17 men) were compared with 10 healthy age-matched control subjects. Using an electromagnetic tracking device, the kinematics of both the contralateral and ipsilateral (i.e. paretic and non-paretic) arm during active and passive abduction and forward flexion were measured and expressed in Euler angles. RESULTS: Scapular lateral rotation relative to the thorax was increased in patients with post-stroke shoulder pain compared with both patients without post-stroke shoulder pain and control subjects at rest as well as during arm abduction and forward flexion. Additionally, glenohumeral elevation was decreased in patients with post-stroke shoulder pain during passive abduction. No differences were found regarding scapula position (displacement relative to the thorax). CONCLUSION: In patients with post-stroke shoulder pain a particular kinematical shoulder pattern was established, characterized by enhanced scapular lateral rotation and diminished glenohumeral mobility.  相似文献   

13.
BackgroundThere are no guidelines for return to driving following upper extremity injury. A greater comprehension of the role of the upper extremity in driving is required to assist clinicians in their fitness-to-drive assessments. This research aims to assist clinicians by analyzing the motion at the upper extremity in safe automobile driving.MethodsThirty-six participants were recruited to the Monash University Accident Research Centre's driving simulator. They were tested in a realistic driving simulation using highway scenarios and traffic hazards. An OptiTrack™ motion tracking system recorded participants' upper limb movements.FindingsThe following ranges of motion were recorded (left and right arm mean whole numbers): The shoulder flexed from 14 to 54°, abducted to 18°and adducted to 9°. Shoulder rotation ranged from 6° external to 32° internal rotation. Elbow flexion ranged from 35° to 72°. Pronation reached 77° and supination to 24°. Wrist flexion reached 34° and extension reached 23°. The wrist deviated to 17°radially and 38° ulnar. To avoid simulated hazards, the steering wheel revolved 57.2° (SD 19.2). The key movements in hazard avoidance are shoulder flexion, shoulder rotation, forearm rotation and wrist deviation.InterpretationShoulder flexion, internal rotation and forearm rotation have been shown to be key upper extremity movements in safe driving. Clinicians can refer to the ranges of motion recorded in this investigation, or the driving task at hand in their fitness-to-drive assessments. The ability to revolve the steering wheel 100° exceeds the 95th percentile of the steering wheel revolution angle required to avoid simulated traffic hazards.  相似文献   

14.
OBJECTIVE. We determined (1) whether active range of motion (AROM) of shoulder flexion and wrist extension measured at the initial therapy evaluation in the acute hospital predicted upper-extremity (UE) motor function 3 mo after stroke and (2) whether the presence of nonmotor impairments influenced this prediction. METHOD. We collected AROM data from 50 people with stroke during their initial acute hospital therapy evaluation and UE motor function data 3 mo later. Multiple regression techniques determined the predictive ability of initial AROM on later UE motor function. RESULTS. Initial AROM explained 28% of the variance in UE motor function 3 mo poststroke. Nonmotor deficits did not contribute to the variance. CONCLUSION. Compared with later AROM measurements, initial values did not adequately predict UE motor function 3 mo after stroke. Clinicians should use caution when informing clients of UE functional prognosis in the early days after stroke.  相似文献   

15.
16.
[Purpose] The aim of the present study was to identify the effects of an unstable support surface (USS) on the activities of trunk and lower extremity muscles during pulley-based shoulder exercise (PBSE). [Subjects] Twenty healthy college students were included in this study. [Methods] Surface EMG was carried out in twenty healthy adult men. The activities of trunk and lower extremity muscles performed during PBSE using a resistance of 14 kg on a stable or unstable support surface were compared. The PBSE included shoulder abduction, adduction, flexion, extension, internal rotation, and external rotation. [Results] On the unstable surface, the rectus abdominis and erector spinae showed significantly less activation during shoulder external rotation, but the extent of activation was not significantly different during other shoulder exercises. The external oblique and rectus femoris showed no significant difference during any shoulder exercises. The tibialis anterior showed significantly greater activation during all shoulder exercises, except flexion and extension. The gastrocnemius showed significantly greater activation during shoulder abduction, extension, and internal rotation. However, during shoulder adduction, flexion, and external rotation, the gastrocnemius showed no significant difference. [Conclusion] The use of USS to increase core stability during PBSE is probably not effective owing to compensatory strategies of the ankle.Key words: Electromyography, Core stability, Ankle strategy  相似文献   

17.
The aim of the study was to evaluate the effect of an intervention including shoulder control and strengthening exercises on function in persons with shoulder impingement. Eight subjects with shoulder impingement were evaluated weekly during the nine weeks of this single-subject design study. The study was divided into three phases (A(1)-B-A(2)) and involved repeated measures of shoulder pain and function (Shoulder Pain And Disability Index (SPADI) questionnaire), painful arc of motion, peak torque and 3-dimensional scapular attitudes. During the intervention phase, each subject participated in 12 exercise sessions supervised by a physiotherapist. Measures taken during the intervention and post-intervention phases were compared to pre-intervention values. All subjects showed significant improvement in the SPADI at the end of the study. A disappearance of a painful arc of motion in flexion and abduction (n=6), an increase in isometric peak torque in lateral rotation (n=3) and abduction (n=2), and changes in the scapular kinematics, mainly in the sagittal plane, were also observed. The present results provide preliminary evidence to support the use of shoulder control exercises to reduce pain and improve function of persons with shoulder impingement.  相似文献   

18.

Background

Researchers have demonstrated moderate evidence for the use of exercise in the treatment of subacromial impingement syndrome (SAIS). Recent evidence also supports eccentric exercise for patients with lower extremity and wrist tendinopathies. However, only a few investigators have examined the effects of eccentric exercise on patients with rotator cuff tendinopathy.

Purpose

To compare the effectiveness of an eccentric progressive resistance exercise (PRE) intervention to a concentric PRE intervention in adults with SAIS.

Study Design

Randomized Clinical Trial

Methods

Thirty‐four participants with SAIS were randomized into concentric (n = 16, mean age: 48.6 ± 14.6 years) and eccentric (n = 18, mean age: 50.1 ± 16.9 years) exercise groups. Supervised rotator cuff and scapular PRE''s were performed twice a week for eight weeks. A daily home program of shoulder stretching and active range of motion (AROM) exercises was performed by both groups. The outcome measures of the Disabilities of the Arm, Shoulder, and Hand (DASH) score, pain‐free arm scapular plane elevation AROM, pain‐free shoulder abduction and external rotation (ER) strength were assessed at baseline, week five, and week eight of the study.

Results

Four separate 2x3 ANOVAs with repeated measures showed no significant difference in any outcome measure between the two groups over time. However, all participants made significant improvements in all outcome measures from baseline to week five (p <  0.0125). Significant improvements also were found from week five to week eight (p < 0.0125) for all outcome measures except scapular plane elevation AROM.

Conclusion

Both eccentric and concentric PRE programs resulted in improved function, AROM, and strength in patients with SAIS. However, no difference was found between the two exercise modes, suggesting that therapists may use exercises that utilize either exercise mode in their treatment of SAIS.

Level of evidence

Therapy, level 1b  相似文献   

19.
Abstract

Mobilization with movement (MWM) is a fairly new therapeutic technique commonly used by physical therapists. The purpose of this case report was to describe the use of MWM in the treatment of a 27-year old left-hand dominant male patient referred to physical therapy with a diagnosis of supraspinatus tendinopathy secondary to impingement. Interventions consisted of MWM and other manual therapy techniques, modalities, and therapeutic exercises. Outcome measures used included goniometric active range of motion (AROM) measurements and manual muscle tests of the shoulder, impingement tests, and the Shoulder Pain and Disability Index (SPADI) and Short Form-36 (SF-36) questionnaires. Specific outcome measures used to describe the response to MWM of the glenohumeral joint included the Numeric Pain Rating Scale (NPRS) and goniometric measurement of abduction AROM. After the first MWM treatment (session 2/12), the 6/10 pre-application NPRS score during shoulder abduction was reduced to 3/10 post-application; however, abduction AROM did not improve (95°). At the final MWM treatment (session 6/12), the pre-application NPRS score during abduction was reduced from 3/10 to 0/10 post-application; abduction AROM increased from 130° to 175°. After 12 sessions, there was a decrease from moderate pain (7/10) to little or no pain (0-1/10) during active shoulder abduction; restricted (95°) to full shoulder abduction active range of motion (180°); and an improvement in the SPADI score from 45% to 8% with no pain or ADL activity difficulty scores >2. This case report indicates that MWM may be an effective treatment intervention for patients with subacromial impingement. Future research is needed to study the efficacy and mechanisms of this treatment technique.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号