1.
BACKGROUND: Different types of coils have been designed for transcatheter closure of persistent arterial ducts. We compared the efficacy and safety of three types of coils: Gianturco coils (Cook), Cook detachable coils (Cook), and Duct Occlud devices (pfm). METHODS: Sixty-three patients underwent coil occlusion of arterial ducts between April 1995 and July 2000. The mean age and weight were 4.8+/-3.4 years and 16.5+/-7.6 kg, respectively. The results and complications of ductal occlusion among the three types of coils were compared. Kaplan-Meier analysis was used to assess reduction in the prevalence of residual shunt with time, and multiple regression analysis was performed to identify predictors of complete occlusion. RESULTS: Coil occlusion of persistent arterial ducts that measured 2. 2 +/- 0.8 mm was feasible in 90% (57/63) of patients. Gianturco coils were used in 29, Duct Occlud devices in 16, and Cook detachable coils in 12 patients. The prevalence of residual shunt at 24 hours, 6 months, 12 months, and 24 months was 42%, 20%, 18%, and 14%, respectively. The reduction in prevalence of residual shunt with time tended to be greater when Gianturco coils were used (P =. 067). Logistic regression identified the use of Gianturco coils to be a significant predictor of complete ductal occlusion on follow-up (P =.04). Pull-through of coils occurred in 4.8% (3/63) and coil embolization in 6.3% (4/63). There was no association between the type of coil and the risk of embolization (P = 1.00). CONCLUSIONS: Transcatheter occlusion of small persistent arterial ducts with coils is safe and effective. There is no advantage of detachable coils (Cook detachable coils and Duct Occlud devices) over nondetachable Gianturco coils in reducing the risk of embolization. Our findings are in favor of the inexpensive, but more effective, Gianturco coils for occluding small arterial ducts of 3 mm or less.  相似文献   

2.
BACKGROUND: The aim of this study was to report the initial experience of using the Gianturco coil (Cook Cardiology, Bloomington, Indiana) without heparinization to close patent ductus arteriosus (PDA). PATIENTS AND METHODS: Forty consecutive patients (30 females, 10 males) underwent transcatheter closure of a PDA via the right femoral artery approach without heparinization. Patients ages ranged from 7 months to 55 years (median, 6.8 years); weights ranged from 7.8 65 kg (median, 18.3 kg). Twenty-one patients had cardiomegaly (n = 21), congestive heart failure (n = 10), or both (n = 10). The PDAs measured 0.8 4.5 mm (median, 2.6 mm) at the narrowest diameter; the mean Qp/Qs ranged from 1.0 2.6 (1.4 +/- 0.4). The helical diameter of the coil that we chose was 1.7 times the narrowest PDA diameter. The length of the coil was sufficient to produce 4 or 5 loops. RESULTS: Successful coil placement was accomplished in all 40 patients. Thirty-five patients (87.5%) underwent single coil implantation, 2 patients (5%) had 2 coils, and 3 patients (7.5%) had 3 coils. Complete ductus occlusion was achieved in 80% of cases at the end of the procedure, while 8 patients had minimal shunt detected by aortography or echocardiography. The occlusion rate increased to 87.5% by the next day, 90% by 1 month, 92.5% by 3 months, 95% by 6 months, and 97.5% by 9 and 12 months. Only one asymptomatic patient had minimal residual shunt detected by color Doppler at 12 months follow-up. At a median follow-up of 17 months (range, 5 25 months), no patient had thromboembolism, endocarditis, coil migration, diminished femoral pulse or hemolysis. CONCLUSION: Our preliminary results suggest that retrograde transcatheter closure of PDA with the Gianturco coil without heparinization is feasible, safe and efficacious. A single coil allowed complete occlusion of PDA 3 mm in diameter.  相似文献   

3.
PURPOSE: To describe the radiographic appearance of the Gianturco and the Cook detachable coils and present the clinical results in patients who underwent transcatheter closure of patent ductus arteriosus. MATERIALS AND METHODS: Between January 1994 and June 1997, eighty-two patients underwent closure of patent ductus arteriosus (PDA) using either Gianturco or Cook detachable coils. The chest x-ray and echocardiography of all patients were reviewed and the following parameters were evaluated: 1) the size of the heart (cardiothoracic ratio), 2) the position and the type of the coils in the postero-anterior and the lateral projection, 3) the number of coils used, 4) the existence of residual ductal flow, 5) Doppler velocity in the left pulmonary artery. RESULTS: Complete occlusion was achieved in 94%, and cardio-thoracic ratio regressed from 0.57 to 0.53 (p < 0.01), after a mean follow-up of 1.2 years. The identification of the different coils on the chest radiograph was successful in only 47% of cases, difficulties arising especially, when multiple coils were used. In 55 patients (67%) the coil position was judged to be optimal, in 27 patients (33%) suboptimal. The latter correlates with the presence of residual shunt. Multiple coils correlated more with a left pulmonary artery flow velocity exceeding 1.5 m/s. CONCLUSION: Coil-occlusion of patent ductus arteriosus is effective and leads to reduced cardio-thoracic ratio. Radiographic coil identification is possible but may be difficult if multiple coils are deployed. Suboptimal coil position led more often to residual PDA shunt. Multiple coils are more commonly associated with increased LPA velocities, but hemodynamic significant obstruction to flow is rare.  相似文献   

4.
应用Cook可控弹簧栓子封堵动脉导管未闭   总被引:5,自引:4,他引:1       下载免费PDF全文
目的 :应用 Cook可控弹簧栓子封堵动脉导管未闭 (PDA)并对其疗效进行评价。方法 :全组共 10例 ,年龄 2~ 35 (平均 11.6 )岁 ,体重 8~ 6 4(平均 30 .6 ) kg,PDA最窄处直径 1.4~ 3.2 (平均 2 .6 ) m m。经导管置入 Cook可控弹簧栓子封堵 PDA。封堵后 10 min行胸主动脉造影评价疗效。术后 3天、1月、6月及 12月行超声心动图检查观察有无残余分流及 PDA再通。结果 :全组技术成功率为 10 0 % ,术后 10 m in胸主动脉造影及术后 3d超声心动图未见残余分流。随访 12个月 ,均未发现 PDA再通及弹簧栓子移位。结论 :应用 Cook可控弹簧栓子封堵小型 PDA是一种安全、有效的非手术方法  相似文献   

5.
6.
Objectives: The present study evaluates two transcatheter closure strategies utilized at a single center and makes recommendations for device selection when occluding the patent ductus arteriosus. Background: A variety of devices are available for transcatheter closure of the patent ductus arteriosus (PDA) but no guidelines exist to guide operator device choice. Methods: A total of 132 patients underwent attempted transcatheter PDA closure utilizing one of two consecutive closure strategies between January 2000 and June 2005. Strategy A (n = 64; January 2000–May 2003) utilized Gianturco coils only. Strategy B (n = 68; June 2003–June 2005) utilized a single Gianturco coil for the PDA with a minimal diameter ≤1 mm (n = 28) or an Amplatzer Duct Occluder (ADO) if the PDA diameter exceeded 1 mm (n = 40). Success was defined as complete occlusion on a follow up echocardiogram. Results: 58 of 64 (90.6%) patients treated utilizing strategy A had successful coil implantation. 68 of 68 (100%) patients treated utilizing strategy B had successful coil/device implantation. At follow up echocardiography, 32 of 44 (72.7%) strategy A patients had complete ductal closure, as compared with 57 of 58 (98.3%) strategy B patients (P < 0.0001). Stepwise logistic regression analysis identified closure strategy as the most powerful predictor of procedural success (OR = 85.9; CI 5.6–9.99). Conclusions: A transcatheter PDA closure strategy consisting of a single Gianturco coil for PDA ≤ 1 mm or an ADO for larger sized PDA (strategy B) achieves superior outcomes compared to the use of coils alone. © 2008 Wiley‐Liss, Inc.  相似文献   

7.
We present the short- and intermediate-term results of transcatheter closure of patent ductus arteriosus with Gianturco coils in adolescents and adults. During a 5-year period, 55 patients (44 females, 11 males) with ages ranging from 14 to 72 years (median, 23) underwent attempted transcatheter closure of patent ductus with the Gianturco coils. The diameter of the narrowest segment of the ductus ranged from 0.8 to 7.6 mm (3.9 +/- 1.3 mm). The 55 patients were divided into three groups. Group I consisted of nine patients with a ductal diameter < or = 3 mm, group II consisted of 27 patients with a ductal diameter > 3 mm but < or = 4 mm, and group III consisted of 19 patients with a ductal diameter > 4 mm. Four- to five-loop Gianturco coils were used, which were deployed via retrograde aortic route. Multiple-coil technique was generally applied in group II patients. Balloon occlusion technique in combination with multiple-coil technique was generally used in group III patients. Deployment of coil was successful in 51 patients (93%) but failed in 4. The success rate of coil deployment in group I, II, and III were 100% (9/9), 96% (26/27), and 84% (16/19), respectively. A mean of 1.9 +/- 0.7 coils was deployed per patient. Of the four patients with unsuccessful coil deployment, three underwent surgery and one received implantation with Amplatzer duct occluder. Distal embolization of 21 coils occurred in 10 patients (3 in group II and 7 in group III), from whom 20 coils were retrieved with a gooseneck snare and 1 coil was removed during surgery. The mean diameter of ductus in the 10 patients with distal embolization was significantly larger than that in those without (5.2 +/- 1.4 vs. 3.7 +/- 1.1 mm; P < 0.01). Among the 51 patients with successful coil deployment, immediate complete closure was achieved in 20 (39%), while trivial to mild leak was present in 31 (61%). No significant complications were encountered. After a follow-up period ranging from 5 to 42 months, four patients had a small residual shunt and three underwent a second intervention with complete occlusion. None had left pulmonary artery stenosis documented with Doppler echocardiography. Transcatheter closure of ductus with the Gianturco coils is safe and feasible in the majority of adolescents and adults. Taking high embolization rate in patients with a ductus diameter > 4 mm into consideration, controlled-release coils, Buttoned device, or Amplatzer duct occluder can be a better choice.  相似文献   

8.
Transcatheter closure of patent ductus arteriosus (PDA) is now a well-established treatment alternative to surgery in many cardiology centers. Of all the methods used, transcatheter coil occlusion is the preferred therapy. For small PDA, the method using 0.038" Gianturco coils has proven safe and effective. However, this therapeutic strategy has encountered some difficulties with large PDA. This study provides an alternative strategy, using 0.052" Gianturco coil and complete closure of residual shunt with multiple coils to close large PDA. Fifteen patients underwent transcatheter coil occlusion of large ( > or = 4mm) patent ductus arteriosus. The intermediate success rate was 86.7%. There were four complications and only two patients had to be referred for surgery.  相似文献   

9.
We report our experience with transcatheter occlusion of the small PDA using Gianturco coils comparing a single coil strategy to a "multiple coil-no residual shunt strategy". Fifteen patients (Group I) had a single coil only placed irrespective of residual shunting and 20 (Group II) were treated using the no residual shunt strategy. Age, minimal PDA diameter, PDA length and PDA types were similar between groups. Closure rates in Group I patients were 60%, 80% and 87% at <1 month, 6 months and 1 year, respectively. In Group II, the <1 month and 6 month closure rates were 100%. The costs and hospital charges for coil closure were comparable to a concurrent surgical group; the total charges (hospital plus physician) were less for Group I, but similar between Group II and the surgical group. The complication rate for coil closure was significantly less than surgical closure. From these data, transcatheter closure with multiple coils can achieve the same closure rate as surgery at similar hospital charges with fewer complications.  相似文献   

10.
经导管介入治疗冠状动脉瘘   总被引:13,自引:0,他引:13  
目的:探讨经导管介入治疗冠状动脉瘘的方法及临床疗效。方法:经导管堵塞冠状动脉瘘14例,平均年龄7.1岁。结果:13例应用弹簧圈堵塞,平均瘘口大小为3.65mm,除3例失败外均获成功;1例(瘘口6.6mm)应用Amplatzer动脉导管未闭堵塞器堵塞成功。所有病例随访1个月-4年,均无残余分流及任何并发症。结论:经导管介入治疗冠状动脉瘘具有良好的临床疗效及安全性。可控弹簧圈一般用于堵塞瘘口较小的冠状动脉瘘,而瘘口较大的冠状动脉瘘可选用Amplatzer动脉导管未闭堵塞器。  相似文献   

11.
Objectives . We report the use of non‐ferromagnetic embolization coils for transcatheter PDA closure. Background . Transcatheter patent ductus arteriosus (PDA) closure has been performed for 40 years. A number of devices have been used with varying degrees of success. Gianturco embolization coils have been used frequently since 1992 with excellent results. These coils are a stainless steel alloy, and create an artifact when subsequent MRI imaging is performed. Methods . Eight patients underwent right and left heart catheterization and transcatheter PDA closure. Angiography displayed a PDA with left to right shunting. The minimum PDA diameter was measured. An Inconel MReye coil was implanted using standard retrograde technique. A postimplant angiogram was performed. Evaluations were performed the following morning and after 2 months. Results . The median age was 5.5 years, median weight was 24 kg. The PDA minimum diameter was 1.7 mm (range 1.4–2.4 mm), with a median Qp:Qs=1.33:1. In all patients, the PDA was completely immediately closed using one Inconel coil. Two patients also had a small aorto‐pulmonary collateral vessel that was occluded using a separate Inconel coil. All patients had follow‐up evaluation the following day; the PDA remained completely occluded and there was no obstruction of the pulmonary artery branches or descending aorta. Seven patients had subsequent follow‐up and echocardiograms; the PDA remained completely occluded. There were no complications. Conclusion . The Inconel MReye coil is safe and effective for coil occlusion of small PDA and aorto‐pulmonary vessels. Additional studies are needed to define the maximum vessel diameter for Inconel coil occlusion. © 2008 Wiley‐Liss, Inc.  相似文献   

12.
A number of patent ductus arteriosus (PDA) occluding devices have been studied in an attempt to develop a transcatheter method of closure of PDA. Some devices were tested in only animal models, whereas others progressed to clinical trials in human subjects. Some devices have been discontinued, some received approval for general clinical use, and many have not yet received approval by regulatory authorities. No prospective randomized clinical trials have been undertaken and, therefore, data on separate clinical trials are used to determine relative efficacy of the devices. Selection of a method of PDA closure depends largely on its minimal diameter and to some degree on its shape. Silent PDAs do not need occlusion. Very small to small PDAs may be occluded by free or detachable Gianturco coils (Cook Cardiology, Bloomington, IN). Moderate-to-large PDAs require closure by devices, conventional surgery, and videothoracoscopic interruption. The choice in the latter group depends largely on the availability of a given method at a given institution at that particular time. Approval of several of the devices by regulatory authorities may result in conduct of prospective randomized clinical trials and use of a device or method most appropriate to the size and shape of the PDA.  相似文献   

13.
Objectives. This report evaluates the use of Gianturco coils to close large patent ductus arteriosus (PDAs) (≥3.5 mm) and describes transvenous delivery of 0.052-in. (0.132-cm) Gianturco coils.

Background. Coil closure of PDAs has become increasingly popular. However, the technique has significant limitations when used to close large PDAs. This report evaluates patient characteristics, PDA anatomy, hemodynamic variables, delivery technique and coil geometry to determine predictors of success.

Methods. Between January 1995 and January 1997, 16 of 118 patients undergoing catheterization for PDA closure were found to have large PDAs. Their median age and weight were 14 months (range 3 months to 43 years) and 8.5 kg (range 3.5 to 73), respectively. The mean PDA diameter was 4.3 mm (range 3.5 to 5.9). Closure of PDAs was attempted using transcatheter delivery of 0.038-in. (0.096-cm) and 0.052-in. coils. Differences in clinical, anatomic, hemodynamic and technical variables between successes and failures were compared.

Results. Eleven (69%) of 16 patients had successful closure of their PDA. Failures occurred only in patients <8 months of age with an indexed PDA diameter >7 mm/m and a pulmonary/systemic flow ratio ≥2.8:1. Use of 0.052-in. coils tended to reduce the incidence of embolization and the number of coils needed for closure.

Conclusions. Patients >8 months of age can have successful closure of large PDAs with currently available Gianturco coils. The 0.052-in. Gianturco coils can be used safely to close large PDAs in infants as small as 6 kg. Increased experience and improved coil design may improve closure rates of large PDAs in infants.  相似文献   


14.
Jackson screwing detachable coils, developed for arterial and venous embolization, have been successfully employed recently for the percutaneous occlusion of patent ductus arteriosus (PDA). Special screwing detachable coils were designed for closure of the PDA, and the experience gained by their use is described in this report. Occlusion was attempted in 29 patients with a minimal ductal diameter of 0.9–4.2 mm. Coils were successfully placed in all 29 patients. One coil, which embolized 10 min after detachment, was retrieved. In 26 patients (89%), complete closure was achieved. Only 35 coils were placed in 29 patients. Residual shunts in three patients are minimal, detectable only on color-flow mapping. Screwing detachable coils for closure of PDA are safe and effective for occlusion of PDA with a minimal diameter <4.2 mm. Embolization of the coil is very rare. A high closure rate is achieved with a low number of placed coils. Cathet. Cardiovasc. Diagn. 41:386–391, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

15.
Transcatheter occlusion of patent ductus arteriosus (PDA) using Gianturco coils (GCs) has been performed for the past decade. However, little has been written regarding anatomical and hemodynamic predictors for successful occlusion of the PDA in infants. This report is to evaluate the outcome of transcatheter occlusion of PDA in symptomatic infants less than 8 kg and to assess predictors of successful occlusion. Retrospective review of catheterization charts and cineangiograms of 42 symptomatic infants who underwent cardiac catheterization for attempted transcatheter occlusion of their PDA was conducted. The hemodynamic and angiographic data evaluated included the length/diameter (L/D) ratio, defined as the length divided by the narrowest diameter of the ductus arteriosus, and preocclusion pulmonary artery pressures. Thirty-one out of 42 patients (74%) had successful occlusion. Twenty-nine out of 42 infants had an L/D ratio > 3. Of these, 26 (90%) had successful occlusion of their PDA. Thirteen out of 42 patients had an L/D ratio < or = 3. Of these, 8 (62%) had unsuccessful occlusion. Complications encountered were transient loss of femoral arterial pulse (n = 6), coil embolization (n = 5), hemolysis (n = 2), and mild left pulmonary artery obstruction (n = 2). No permanent loss of femoral arterial pulse was noted. These complications resulted in no mortality and minimal morbidity. The L/D ratio was the strongest predictor of successful outcome, with an L/D ratio greater than 3.0 being more amenable to transcatheter occlusion (odds ratio of 4.6). Other predictors for success included lower preocclusion systolic, diastolic, and mean pulmonary artery pressure and smaller ductal diameter. Our conclusion was that infants less than 8 kg with an L/D ratio > 3.0 can safely and successfully undergo transcatheter occlusion of their PDA using transcatheter coils.  相似文献   

16.
Transcatheter coil occlusion of the patent ductus arteriosus (PDA) has become the interventional treatment option of choice. Immediate occlusion of any residual shunting results in excellent closure rates, but frequently requires multiple coil deployment. Aims: To assess the efficacy and limitations of single Cook detachable coil PDA closure compared to a preceding series of Rashkind umbrella procedures. Methods and results: Between 1990 and 1999, transcatheter occlusion of a small (<2 mm; n=45) or moderate-sized (2-4 mm; n=47) PDA was successfully attempted in 90/92 consecutive patients (mean age 6+/-4.8 years) with a coil (39/41) or Rashkind device (51/51). Immediate angiographic closure rates for both devices were low, although better for small (54-68%) than moderate ducts (7-22%, P<0.01). A 2-year echocardiographic closure rate of small ducts increased to 92% for the coil group versus 95% for the Rashkind group. By that time, moderate-sized ducts were only occluded in 64% with the coil and 54% with the Rashkind device. A visible residual shunt at post-implant angiography in moderate ducts was associated with a high incidence (59%) of long-term echocardiographic shunt patency and a need for repeat interventions for audible residual shunts (32%). Conclusions: Single coil transcatheter occlusion is the treatment of choice for the small duct as most residual shunts will resolve spontaneously. However, long-term shunt persistence after single coil deployment in moderate sized ducts is as frequent as with the Rashkind device. A primary multiple coil approach is advocated if the postcoil aortogram shows residual ductal shunting and if there is persistence of a ductal murmur on auscultation.  相似文献   

17.
OBJECTIVE: To assess the immediate and mid-term results of transcatheter closure of patent ductus arteriosus (PDA) > or = 4 mm with multiple Gianturco coils. (Transcatheter closure of large PDAs using the Rashkind occluder or the buttoned device is associated with a 7-38% incidence of residual shunt.) METHODS: 19 patients (7 male, 12 female) underwent an attempt at anterograde transcatheter closure with multiple Gianturco coils of a large PDA at a median age of 3.8 yr (range 2 weeks-34 yr) and median weight of 14 kg (range 2.3-80 kg). RESULTS: The median PDA diameter at the narrowest segment was 4.3 mm (range 4-7 mm) and the mean (SD) Qp/Qs was 1.9 (0.8). Each patient had left atrial and left ventricular volume overload. A 4F catheter was used to deliver the coils in all patients. There was immediate and complete closure in 16/18; one patient had residual shunt that was closed at a second procedure and the other had spontaneous disappearance of the residual shunt at the six week visit. A short ductus (angiographic type B) in one patient could not be closed. The median number of coils placed at the first attempt to close the ductus was 4 (range 2-6 coils) and the median fluoroscopy time was 40 minutes (range 13-152 minutes). Mild left pulmonary artery stenosis occurred in the two smallest patients. Coil migration to the lung occurred in 3 patients with retrieval of coils in two patients. All procedures but one were done on an outpatient basis. At a median follow up of 1.6 yr (range 2 weeks-2.2 yr) all patients had complete closure with no new complications. CONCLUSIONS: Anterograde transcatheter closure with multiple Gianturco coils is an effective treatment for most patients with large PDA of diameters up to 7 mm. This technique can be performed in small infants on an outpatient basis without the need for general endotracheal anaesthesia.  相似文献   

18.
Different coils have been used to close the patient ductus arteriosus (PDA). In small- and moderate-sized PDA, coils are an adequate alternative to surgery and/or to other devices. The aim of the study is to review and discuss the advantages and disadvantages of using coils (excluding PFM coils PFM Medical, Germany) to close PDA. Cambier was the first to successfully close a PDA using a Gianturco coil. To date, thousands of patients worldwide have undergone transcatheter closure of PDA using this or other types of coils. The use of coils is analyzed with regard to costs in comparison with other therapeutic modalities; techniques--anterograde, retrograde approach, selection of coil size--in relation to the size of the PDA and the available sizes of coils; efficacy of the rate of complete occlusion and the need for reocclusion; and safety in relation to embolization rate, other complications including hemolysis, left pulmonary artery LPA stenosis and coarctation. It is concluded that coils are a cheap alternative for the occlusion of PDA in the small-to-moderate PDA. The technique can be learned quite quickly, it has a high rate of complete occlusion, and has an acceptable rate of safety. The disadvantages include a moderate rate of coil embolization and of hemolysis in patients with residual shunt after coil occlusion in large PDAs. When more than one coil is used, the potential for developing LPA stenosis is high.  相似文献   

19.
Background and hypothesis: Although results of surgical ligation of the patent ductus arteriosus (PDA) in the pediatric age group are excellent, surgical management of the adult with a PDA may be more problematic. The PDA that presents in adulthood may be calcified and friable, rendering simple ligation via a thoracotomy difficult, inadequate, and hazardous. Patch closure of the ductus arteriosus from either the aortic or pulmonary artery orifice using cardiopulmonary bypass or transient aortic cross-clamping is necessary but increases surgical risks. Furthermore, older patients with diseases unrelated to their PDA and patients with Down's syndrome may have higher risks with intubation, general anesthesia, and surgery. Early results of percutaneous transcatheter occlusion of the PDA with Gianturco coils performed under sedation and local anesthesia are promising. Methods: Six adults with mean age of 39.1 years (range 23.1–62.0 years) were found to have an isolated PDA with mean minimum diameter of 2.7 mm (range 1.0–5.0 mm) at cardiac catheterization. All underwent percutaneous transcatheter occulsion of the PDA using Gianturco coils. Results: Coil implantation was successful in all patients. There were no complications and all were discharged home within 24 hours. Complete ductal occlusion was seen immediately in 4 of 6 patients (67%) while 2 of 6 (33%) had small residual leaks. However, complete occlusion was achieved in all patients by 6 months following the procedure. Conclusion: Transcatheter occlusion of the PDA using coils is safe and efficacious in adults.  相似文献   

20.
Background: The Rashkind Umbrella device has proven effective in closing small to moderate size patent ductus arteriosus. A comparable early occlusion rate was also seen in PDA occlusion using Gianturco coils. This study addresses the long-term outcome of both techniques in a single centre. Methods: Review was undertaken of 522 patients with PDA who underwent transcatheter occlusion before January 1997; 244 patients (mean: age 8.0±6.7 years, weight 21.8±12.9 kg, PDA size 3.2±1.0 mm) were intended to receive the Rashkind Umbrella device and the remaining 278 patients (mean: age 6.4±5.6 years, weight 18.6±11.2 kg, PDA size 2.5±1.0 mm) would receive Gianturco coils. Deployment failure occurred in 8 patients (3%) and 6 (2%) during the initial learning curve of the Rashkind Umbrella and Gianturco coil, respectively. In the Rashkind Umbrella group, haemolysis occurred in 6, device embolisation in 3, and 1 patient died from anaesthetic sequelae. Peripheral pulmonary embolisation of coils occurred in 7 patients and all were successfully retrieved. Results: Results were analysed from 228 and 258 patients who had successful Rashkind Umbrella device and Gianturco coil deployment respectively. All had completed at least 1 year follow-up. They were evaluated clinically for residual ductal murmur and echocardiographically for a residual ductal shunt and presence of pulmonary artery or aortic obstruction. The Rashkind Umbrella group had significantly higher residual shunt compared to the Gianturco coil group at various stages of follow-up (p<0.05), 40% v 22% at 24 hours, 29% v 7% at 3 months, 25% v 4% at 6 months and 22% v 3% at 1 year. In 57 patients, a reocclusion procedure during the study period was undertaken to effect immediate complete occlusion. Mild left pulmonary artery stenosis (velocity<2 m/s) was noted in 6 patients who had multiple coils and one who had a 17 mm Rashkind Umbrella device. Conclusions: Transcatheter occlusion of PDA using the Gianturco coil is safer and more effective than the Rashkind Umbrella device. It has become the first choice for treating small to moderate size native PDA at our institution.  相似文献   