首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
We compare different radiotherapy techniques-helical tomotherapy (tomotherapy), step-and-shoot IMRT (IMRT), and 3-dimensional conformal radiotherapy (3DCRT)-for patients with mid-distal esophageal carcinoma on the basis of dosimetric analysis. Six patients with locally advanced mid-distal esophageal carcinoma were treated with neoadjuvant chemoradiation followed by surgery. Radiotherapy included 50 Gy to gross planning target volume (PTV) and 45 Gy to elective PTV in 25 fractions. Tomotherapy, IMRT, and 3DCRT plans were generated. Dose-volume histograms (DVHs), homogeneity index (HI), volumes of lung receiving more than 10, 15, or 20 Gy (V(10), V(15), V(20)), and volumes of heart receiving more than 30 or 45 Gy (V(30), V(45)) were determined. Statistical analysis was performed by paired t-tests. By isodose distributions and DVHs, tomotherapy plans showed sharper dose gradients, more conformal coverage, and better HI for both gross and elective PTVs compared with IMRT or 3DCRT plans. Mean V(20) of lung was significantly reduced in tomotherapy plans. However, tomotherapy and IMRT plans resulted in larger V(10) of lung compared to 3DCRT plans. The heart was significantly spared in tomotherapy and IMRT plans compared to 3DCRT plans in terms of V(30) and V(45). We conclude that tomotherapy plans are superior in terms of target conformity, dose homogeneity, and V(20) of lung.  相似文献   

3.
This study was designed to assess the feasibility and potential benefit of using intensity-modulated radiotherapy (IMRT) planning for patients newly diagnosed with glioblastoma multiforme (GBM). Five consecutive patients with confirmed histopathologically GBM were entered into the study. These patients were planned and treated with 3-dimensional conformal radiation therapy (3DCRT) using our standard plan of 3 noncoplanar wedged fields. They were then replanned with the IMRT method that included a simultaneous boost to the gross tumor volume (GTV). The dose distributions and dose-volume histograms (DHVs) for the planning treatment volume (PTV), GTV, and the relevant critical structures, as obtained with 3DCRT and IMRT, respectively, were compared. In both the 3DCRT and IMRT plans, 59.4 Gy was delivered to the GTV plus a margin of 2.5 cm, with doses to critical structures below the tolerance threshold. However, with the simultaneous boost in IMRT, a higher tumor dose of 70 Gy could be delivered to the GTV, while still maintaining the uninvolved brain at dose levels of the 3DCRT technique. In addition, our experience indicated that IMRT planning is less labor intensive and time consuming than 3DCRT planning. Our study shows that IMRT planning is feasible and efficient for radiotherapy of GBM. In particular, IMRT can deliver a simultaneous boost to the GTV while better sparing the normal brain and other critical structures.  相似文献   

4.
The purpose of this study was to evaluate the dosimetric variation among six non-beam-matched Varian linacs using different techniques for the same plans. Six non-beam-matched Varian machines, comprising two Clinac iX, two 600 C/D (Unique), and two True Beam Tx photon 6 MV X-ray devices were acquired. Sixty patients with of head and neck (H&N; 30) and pelvic (30) treatment sites were chosen. For all 60 patients, three-dimensional conformal radiotherapy (3DCRT), intensity-modulated radiotherapy (IMRT), and volumetric-modulated radiotherapy (VMAT) plans were generated for the Clinac iX-1 device; all plans were migrated to the remaining machines, using the eclipse treatment planning system without any modification. The dosimetric variation among the six machines for each target volume and organ at risk was recorded and analyzed. In H&N cases, the maximum variation among the six machines with 3DCRT, IMRT, and VMAT was 2.57%, 2.6%, and 2.6%, respectively. In pelvic cases, the maximum variation among the six machines with 3DCRT, IMRT, and VMAT was 2.2%, 1.95%, and 2.05%, respectively. Our overall results show that dosimetric variation, while interchanging the plans among the six machines at phantom and patient levels, remains within the limits of clinical acceptability. The noted variation was not correlated with any of these treatment techniques: 3DCRT, IMRT, or VMAT.  相似文献   

5.
When treating prostate patients having a metallic prosthesis with radiation, a 3D conformal radiotherapy (3DCRT) treatment plan is commonly created using only those fields that avoid the prosthesis in the beam’s-eye view (BEV). With a limited number of portals, the resulting plan may compromise the dose sparing of the rectum and bladder. In this work, we investigate the feasibility of using intensity-modulated radiotherapy (IMRT) to treat prostate patients having a metallic prosthesis. Three patients, each with a single metallic prosthesis, who were previously treated at the University of Chicago Medical Center for prostate cancer, were selected for this study. Clinical target volumes (CTV = prostate + seminal vesicles), bladder, and rectum volumes were identified on CT slices. Planning target volumes (PTV) were generated in 3D by a 1-cm expansion of the CTVs. For these comparative studies, treatment plans were generated from CT data using 3DCRT and IMRT treatment planning systems. The IMRT plans used 9 equally-spaced 6-MV coplanar fields, with each field avoiding the prosthesis. The 3DCRT plans used 5 coplanar 18-MV fields, with each field avoiding the prosthesis. A 1-cm margin around the PTV was used for the blocks. Each of the 9-field IMRT plans spared the bladder and rectum better than the corresponding 3DCRT plan. In the IMRT, plans, a bladder volume receiving 80% or greater dose decreased by 20–77 cc, and a volume rectal volume receiving 80% or greater dose decreased by 24–40 cc. One negative feature of the IMRT plans was the homogeneity across the target, which ranged from 95% to 115%.  相似文献   

6.
PURPOSE: To compare helical tomotherapy (HT) and conventional intensity-modulated radiotherapy (IMRT) using a variety of dosimetric and radiobiologic indexes in patients with locally advanced non-small cell lung cancer (LA-NSCLC). PATIENTS AND METHODS: A total of 20?patients with LA-NSCLC were enrolled. IMRT plans with 4-6 coplanar beams and HT plans were generated for each patient. Dose distributions and dosimetric indexes for the tumors and critical structures were computed for both plans and compared. RESULTS: Both modalities created highly conformal plans. They did not differ in the volumes of lung exposed to >?20?Gy of radiation. The average mean lung dose, volume receiving ≥?30?Gy, and volume receiving ≥?10?Gy in HT planning were 18.3?Gy, 18.5%, and 57.1%, respectively, compared to 19.4?Gy, 25.4%, and 48.9%, respectively, with IMRT (p?=?0.004, p?相似文献   

7.
The purpose of this work was to develop a robust technique for planning intensity-modulated radiation therapy (IMRT) for prostate cancer patients who are to be entered into a proposed hypofractionated dose escalation study. In this study the dose escalation will be restricted to the prostate alone, which may be regarded as a concurrent boost volume within the overall planning target volume (PTV). The dose to the prostate itself is to be delivered in 3 Gy fractions, and for this phase of the study the total prostate dose will be 57 Gy in 19 fractions, with 50 Gy prescribed to the rest of the PTV. If acute toxicity results are acceptable, the next phase will escalate doses to 60 Gy in 20 x 3 Gy fractions. There will be 30 patients in each arm. This work describes the class solution which was developed to create IMRT plans for this study, and which enabled the same set of inverse planning parameters to be used during optimization for every patient with minimal planner intervention. The resulting dose distributions were compared with those that would be achieved from a 3D conformal radiotherapy (3DCRT) technique that used a multileaf collimator (MLC) but no intensity modulation to treat the PTV, followed by a sequential boost to raise the prostate to 57 Gy. The two methods were tested on anatomical data sets for a series of 10 patients who would have been eligible for this study, and the techniques were compared in terms of doses to the target volumes and the organs at risk. The IMRT method resulted in much greater sparing of the rectum and bladder than the 3DCRT technique, whilst still delivering acceptable doses to the target volumes. In particular, the volume of rectum receiving the minimum PTV dose of 47.5 Gy was reduced from a mean value of 36.9% (range 23.4% to 61.0%) to 18.6% (10.3% to 29.0%). In conclusion, it was found possible to use a class solution approach to produce IMRT dose escalated plans. This IMRT technique has since been implemented clinically for patients enrolled in the hypofractionated dose escalation study.  相似文献   

8.

Purpose

To make dosimetric comparisons of volumetric-modulated arc therapy (VMAT) and 7-field intensity-modulated radiotherapy (IMRT) with dynamic MLCs using the Monaco treatment planning system with Monte Carlo algorithm.

Materials and methods

Single-arc VMAT and 7-field IMRT treatment plans were compared for 12 intermediate risk prostate cancer patients treated with prostate and seminal vesicle radiotherapy. For all patients, the prescribed dose was 78 Gy delivered in 39 fractions. The dosimetric data of IMRT and VMAT plans with 6, 10 and 15 MV energies were compared. The comparison was made for target volume, organs at risk (OAR) doses, and for monitor units (MU).

Results

The normal tissue surrounding the target were lower in VMAT plans compared to IMRT plans. VMAT plans achieved lower doses to all OARs for nearly all dosimetric endpoints. VMAT plans achieved 9.4, 9.0 and 7.0 % relative decrease in MUs required for RT delivery, for 6, 10 and 15 MV energy levels, respectively. The target volume and OAR dosimetric values did not differ significantly between 6, 10 and 15 MV photon energies.

Conclusion

VMAT plans were found to be dosimetrically equivalent to IMRT plans for prostate cancer patients, with better rectum and bladder sparing and fewer MUs required.  相似文献   

9.
目的:探讨三维适形(含电子线照射野)的照射技术治疗双眶Grave’s眼病的实施方法及其剂量学优势。方法10例确诊为双侧Grave’ s眼病的患者,均用三维适形(含电子线照射野)照射技术、传统的对穿野照射技术以及近年来主流的调强照射技术等三种技术完成治疗计划,比较计划靶区(planning target volume,PTV)和危及器官(organ at risk,OAR)的剂量分布图、剂量体积直方图和剂量学参数。结果对于PTV的参数D98%、V95%、Dmean、CI和HI,双侧晶体的参数Dmin、Dmean和Dmax,双侧泪腺的参数Dmin和Dmean,三维适形和调强技术二者与对穿野技术相比差异均具有统计学意义(P<0.05),但三维适形与调强技术相比差异无统计学意义。对于PTV的参数D2%和双侧泪腺的参数Dmax,则三种技术之间比较差异均无统计学意义。结论三维适形(含电子线照射野)和调强技术与传统的对穿野技术相比都有着同样的剂量学优势,在患者不愿意接受调强技术昂贵的价格或者没有调强设备的时候,可以用三维适形技术代替。  相似文献   

10.
The purpose of this study was to establish intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) treatment plans for synchronous bilateral breast cancer (SBBC) and to compare those plans with the previous treatment plans using 3D conformal radiation therapy (3DCRT). The differences among the treatments were also statistically compared regarding dosimetry distribution and treatment efficiency. The research was conducted with 10 SBBC patients. The study established IMRT (12 fields with a single isocenter) and VMAT (2 partial arcs with a single isocenter) treatment plans for SBBC patients and then compared those plans with 3DCRT (8 fields with multiple isocenters). The plans were evaluated based on a dose-volume histogram analysis. For planning target volumes (PTVs), the mean doses and the values of V95%, V105%, conformity index, and homogeneity index were reported. For the organs at risk, the analysis included the mean dose, maximum dose, and VXGy, depending on the organs (lungs, heart, and liver). To objectively evaluate the efficiency of the treatment plans, each plan's beam times, treatment times (including set-up time), and monitor units were compared. Tukey test and one-way analysis of variance were used to compare the PTV and organs at risk values of the 3 techniques. Additionally, the independent-samples t-test was used to compare the 2 techniques (IMRT and VMAT) based on the values of Rt. PTV and Lt. PTV (p?<?0.05). For PTV dose distribution, IMRT showed increases of approximately 1.2% in Dmean and of approximately 5.7% in V95% dose distribution compared with 3DCRT. In comparison to VMAT, 3DCRT showed about 3.0% higher dose distribution in Dmean and V95%. IMRT was the best in terms of conformity index and homogeneity index (p?<?0.05), whereas 3DCRT and VMAT did not significantly differ from each other. In terms of dose distribution on lungs, heart, and liver, the percentage of volume at high doses such as V30Gy and V40Gy was approximately 70% lower for IMRT and approximately 40% lower for VMAT than for 3DCRT. For distribution volumes of low doses such as V5% and V10%, that for 3DCRT was approximately 60% smaller than for IMRT and approximately 70% smaller than for VMAT. Comparison between IMRT and VMAT showed that the IMRT was superior in all distribution factors. VMAT showed better treatment efficiency than 3DCRT or IMRT. Among the SBBC radiotherapy treatment plans, IMRT was superior to 3DCRT and VMAT in terms of PTV dose distribution, whereas VMAT showed the most outstanding treatment efficiency.  相似文献   

11.
The focus of this work is to evaluate the dosimetric impact of treatment planning for three-dimensional conformal radiotherapy (3DCRT) and intensity-modulated radiotherapy (IMRT) of prostate cancer using Varian/BrainLAB 120-leaf high-definition multileaf collimator (HD120 MLC) with 2.5 mm leaf width and Varian 120-leaf millennium multileaf collimator (M120 MLC) with 5 mm leaf width. We measured the leaf transmission and dosimetric leaf gap (DLG) of two multileaf collimator (MLC) systems using Farmer ionization chamber. The dosimetric impact of treatment planning for 3DCRT and IMRT of prostate cancer for ten clinical cases using two MLC systems was evaluated quantitatively. 3DCRT was divided to 3DCRT(middle) as fitting at middle of leaf tip and 3DCRT(outside) as fitting at outside of leaf tip. The leaf transmission factor and DLG of HD120 MLC for 6 and 10 MV X-ray decreased by 0.2% and 1 mm, respectively, compared to M120 MLC. The mean conformity index of PTV of treatment planning for prostate 3DCRT(middle), 3DCRT(outside) , and IMRT decreased by 0.9%, 6.6%, and 0.9% and the mean homogeneity index increased 2.3%, 13.0%, and 4.2%, respectively. The mean V20, V40, and V65 decreased by 2.4%, 6.6%, and 4.5% for bladder and 3.3%, 6.1%, and 5.9% for rectum, respectively. The results of this work demonstrated that the dose conformity of PTV improved and the dose of bladder and rectum decreased for 3DCRT and IMRT of prostate cancer using HD120 MLC compared to M120 MLC, because of reduction of leaf width, leaf transmission, and rounded leaf end transmission.  相似文献   

12.
This study investigated the dosimetric advantages of inversely planned intensity-modulated radiotherapy (IMRT) over forward-planned conventional 3D conformal radiotherapy (3D-CRT) in treating lung cancer patients at escalated dose. Three consecutively accrued patients on the RTOG 93-11 dose-escalation protocol were replanned using IMRT with the same dosimetric rules, so that the isodose distributions and dose-volume histograms could be generated and compared. The Helax-TMS treatment planning system, with an IMRT optimization module (version 6.0), was used. In all cases, a consistent approach of inverse planning and set of dose-volume constraints (DVCs) provided improved critical structure sparing. However, the minimum dose in PTV was generally below that achieved with the corresponding forward planned 3D-CRT.  相似文献   

13.
The purpose of this study was to evaluate the clinical implementation of tangential field IMRT using sliding window technique and to compare dosimetric parameters with 3-dimensional conformal radiation therapy (3DCRT). Twenty breast cancer patients were randomly selected for comparison of intensity modulated radiation therapy (IMRT)-based treatment plan with 3DCRT. Inverse treatment was performed using the sliding window technique, employing the Eclipse® Planning System (version 7.1.59, Varian, Palo Alto, CA). The dosimetric parameters compared were V95 (the percentage of target volume getting ≥95% of prescribed dose), V105, V110, and dose homogeneity index, DHI (percentage of target volume getting between 95% and 110% of prescribed dose). The mean V95, DHI, V105, and V110 for target volume for IMRT vs. 3D were 90.6% (standard deviation [SD]: 3.2) vs. 91% (SD: 3.0), 87.7 (SD: 6.0) vs. 82.6 (SD: 7.8), 27.3% (SD: 20.3) vs. 49.4% (SD: 14.3), and 2.8 (SD: 5.6) vs. 8.4% (SD: 7.4), respectively. DHI was increased by 6.3% with IMRT compared to 3DCRT (p < 0.05). The reductions of V105 and V110 for the IMRT compared to 3DCRT were 44.7% and 66.3%, respectively (p < 0.01). The mean dose and V30 for heart with IMRT were 2.3 (SD: 1.1) and 1.05 (SD: 1.5) respectively, which was a reduction by 6.8% and 7.9%, respectively, in comparison with 3D. Similarly, the mean dose and V20 for the ipsilateral lung and the percentage of volume of contralateral volume lung receiving > 5% of prescribed dose with IMRT were reduced by 9.9%, 2.2%, and 35%, respectively. The mean of total monitor units used for IMRT and 3DCRT was about the same (397 vs. 387). The tangential field IMRT for intact breast using sliding window technique was successfully implemented in the clinic. We have now treated more than 1000 breast cancer patients with this technique. The dosimetric data suggest improved dose homogeneity in the breast and reduction in the dose to lung and heart for IMRT treatments, which may be of clinical value in potentially contributing to improved cosmetic results and reduced late treatment-related toxicity.  相似文献   

14.
《Medical Dosimetry》2014,39(2):180-184
The purpose of this study is to analyze the dosimetric effect of Elekta Beam Modulator in 3-dimensional conformal radiation therapy (3DCRT) and in intensity-modulated radiation therapy (IMRT) for localized prostate cancer. We compared treatment plans developed with 2 different Elekta multileaf collimators (MLC): Beam Modulator micro-MLC (mMLC) (4-mm leaf width at the isocenter) and standard MLC (10-mm leaf width at the isocenter). The comparison was performed for 15 patients with localized prostate cancer in 3DCRT and IMRT delivery; a total of 60 treatment plans were processed. The dose-volume histograms were used to provide the quantitative comparison between plans. In particular, we analyzed differences between rectum and bladder sparing in terms of a set of appropriate Vx (percentage of organ at risk [OAR] volume receiving the x dose) and differences between target conformity and coverage in terms of coverage factor and conformation number. Our analysis demonstrates that in 3DCRT there is an advantage in the use of Elekta Beam Modulator mMLC in terms of organ sparing; in particular, a significant decrease in rectal V60 and V50 (p = 0.001) and in bladder V70 and V65 (p = 0.007 and 0.002, respectively) was found. Moreover, a better target dose conformity was obtained (p = 0.002). IMRT plans comparison demonstrated no significant differences between the use of the 4 or 10-mm MLCs. Our analysis shows that in 3DCRT the use of the Elekta Beam Modulator mMLC gives a gain in target conformity and in OARs dose sparing whereas in IMRT plans there is no advantage.  相似文献   

15.
The emergent use of a combined modality approach (chemotherapy and radiation) in pancreatic cancer is associated with increased gastrointestinal toxicity. Intensity-modulated radiation therapy (IMRT) has the potential to deliver adequate dose to the tumor volume while decreasing the dose to critical structures such as the small bowel. We evaluated the influence of IMRT with inverse treatment planning on the dose-volume histograms (DVHs) of normal tissue compared to standard 3-dimensional conformal radiation treatment (3D-CRT) in patients with pancreatic cancer. Between July 1999 and May 2001, 10 randomly selected patients with adenocarcinoma of the pancreatic head were planned simultaneously with 3D-CRT and inverse-planned IMRT using the volume at risk approach (VaRA) and compared for various dosimetric parameters. DVH and normal tissue complication probability (NTCP) were calculated using IMRT and 3D-CRT plans. The aim of the treatment plan was to deliver 61.2 Gy to the gross tumor volume (GTV) and 45 Gy to the clinical treatment volume (CTV) while maintaining critical normal tissues to below specified tolerances. IMRT plans were more conformal than 3D-CRT plans. The average dose delivered to one third of the small bowel was lower with the IMRT plan compared to 3D-CRT. The IMRT plan resulted in one third of the small bowel receiving 30.2+/-12.9 Gy vs. 38.5+/-14.2 Gy with 3D-CRT (p = 0.006). The median volume of small bowel that received greater than either 50 or 60 Gy was reduced with IMRT. The median volume of small bowel exceeding 50 Gy was 19.2+/-11.2% (range 3% to 45%) compared to 31.4+/-21.3 (range 7% to 70%) for 3D-CRT (p = 0.048). The median volume of small bowel that received greater than 60 Gy was 12.5+/-4.8% for IMRT compared to 19.8+/-18.6% for 3D-CRT (p = 0.034). The VaRA approach employing IMRT techniques resulted in a lower dose per volume of small bowel that exceeded 60 Gy. We used the Lyman-Kutcher models to compare the probability of small bowel injury employing IMRT compared to 3D-CRT. The BIOPLAN model predicted a small bowel complication probability of 9.3+/-6% with IMRT compared to 24.4+/-18.9% with 3D-CRT delivery of dose (p = 0.021). IMRT with an inverse treatment plan has the potential to significantly improve radiation therapy of pancreatic cancers by reducing normal tissue dose, and simultaneously allow escalation of dose to further enhance locoregional control.  相似文献   

16.
The purpose of this study was to evaluate the clinical implementation of tangential field IMRT using sliding window technique and to compare dosimetric parameters with 3-dimensional conformal radiation therapy (3DCRT). Twenty breast cancer patients were randomly selected for comparison of intensity modulated radiation therapy (IMRT)-based treatment plan with 3DCRT. Inverse treatment was performed using the sliding window technique, employing the Eclipse® Planning System (version 7.1.59, Varian, Palo Alto, CA). The dosimetric parameters compared were V95 (the percentage of target volume getting ≥95% of prescribed dose), V105, V110, and dose homogeneity index, DHI (percentage of target volume getting between 95% and 110% of prescribed dose). The mean V95, DHI, V105, and V110 for target volume for IMRT vs. 3D were 90.6% (standard deviation [SD]: 3.2) vs. 91% (SD: 3.0), 87.7 (SD: 6.0) vs. 82.6 (SD: 7.8), 27.3% (SD: 20.3) vs. 49.4% (SD: 14.3), and 2.8 (SD: 5.6) vs. 8.4% (SD: 7.4), respectively. DHI was increased by 6.3% with IMRT compared to 3DCRT (p < 0.05). The reductions of V105 and V110 for the IMRT compared to 3DCRT were 44.7% and 66.3%, respectively (p < 0.01). The mean dose and V30 for heart with IMRT were 2.3 (SD: 1.1) and 1.05 (SD: 1.5) respectively, which was a reduction by 6.8% and 7.9%, respectively, in comparison with 3D. Similarly, the mean dose and V20 for the ipsilateral lung and the percentage of volume of contralateral volume lung receiving > 5% of prescribed dose with IMRT were reduced by 9.9%, 2.2%, and 35%, respectively. The mean of total monitor units used for IMRT and 3DCRT was about the same (397 vs. 387). The tangential field IMRT for intact breast using sliding window technique was successfully implemented in the clinic. We have now treated more than 1000 breast cancer patients with this technique. The dosimetric data suggest improved dose homogeneity in the breast and reduction in the dose to lung and heart for IMRT treatments, which may be of clinical value in potentially contributing to improved cosmetic results and reduced late treatment-related toxicity.  相似文献   

17.
《Medical Dosimetry》2014,39(4):330-336
Reirradiation of patients who were previously treated with radiotherapy is vastly challenging. Pulsed low–dose rate (PLDR) external beam radiotherapy has the potential to reduce normal tissue toxicities while providing significant tumor control for recurrent cancers. This work investigates treatment planning techniques for intensity-modulated radiation therapy (IMRT)-based PLDR treatment of various sites, including cases with pancreatic and prostate cancer. A total of 20 patients with clinical recurrence were selected for this study, including 10 cases with pancreatic cancer and 10 with prostate cancer. Large variations in the target volume were included to test the ability of IMRT using the existing treatment planning system and optimization algorithm to deliver uniform doses in individual gantry angles/fields for PLDR treatments. Treatment plans were generated with 10 gantry angles using the step-and-shoot IMRT delivery technique, which can be delivered in 3-minute intervals to achieve an effective low dose rate of 6.7 cGy/min. Instead of dose constraints on critical structures, ring structures were mainly used in PLDR-IMRT optimization. In this study, the PLDR-IMRT plans were compared with the PLDR-3-dimensional conformal radiation therapy (3DCRT) plans and the PLDR-RapidArc plans. For the 10 cases with pancreatic cancer that were investigated, the mean planning target volume (PTV) dose for each gantry angle in the PLDR-IMRT plans ranged from 17.6 to 22.4 cGy. The maximum doses ranged between 22.9 and 34.8 cGy. The minimum doses ranged from 8.2 to 17.5 cGy. For the 10 cases with prostate cancer that were investigated, the mean PTV doses for individual gantry angles ranged from 18.8 to 22.6 cGy. The maximum doses per gantry angle were between 24.0 and 34.7 cGy. The minimum doses per gantry angle ranged from 4.4 to 17.4 cGy. A significant reduction in the organ at risk (OAR) dose was observed with the PLDR-IMRT plan when compared with that using the PLDR-3DCRT plan. The volume receiving an 18-Gy (V18) dose for the left and right kidneys was reduced by 10.6% and 12.5%, respectively, for the pancreatic plans. The volume receiving a 45-Gy (V45) dose for the small bowel decreased from 65.3% to 45.5%. For the cases with prostate cancer, the volume receiving a 40-Gy (V40) dose for the bladder and the rectum was reduced significantly by 25.1% and 51.2%, respectively. When compared with the RapidArc technique, the volume receiving a 30-Gy (V30) dose for the left and the right kidneys was lower in the IMRT plans. For most OARs, no significant differences were observed between the PLDR-IMRT and the PLDR-RapidArc plans. These results clearly demonstrated that the PLDR-IMRT plan was suitable for PLDR pancreatic and prostate cancer treatments in terms of the overall plan quality. A significant reduction in the OAR dose was achieved with the PLDR-IMRT plan when compared with that using the PLDR-3DCRT plan. For most OARs, no significant differences were observed between the PLDR-IMRT and the PLDR-RapidArc plans. When compared with the PLDR-3DCRT plan, the PLDR-IMRT plan could provide superior target coverage and normal tissue sparing for PLDR reirradiation of recurrent pancreatic and prostate cancers. The PLDR-IMRT plan is an effective treatment choice for recurrent cancers in most cancer centers.  相似文献   

18.
19.
PURPOSE: Limited information is available comparing target volume and normal tissue dosimetry with the different techniques of partial breast irradiation (PBI). We present results of a dosimetric comparison of single catheter, balloon-based brachytherapy using the MammoSite catheter (BRT), 3D conformal radiation therapy (3DCRT), and intensity-modulated radiation therapy (IMRT). METHODS AND MATERIALS: Fifteen patients were treated using the BRT device. With the use of CT scans with balloons in inflated and deflated states, plans were developed for each patient using each of the methods of PBI, for a total of 45 plans. The plans were then compared using the below dosimetric parameters. RESULTS: The mean V100 was 95%, 92%, and 94% for the BRT, 3DCRT, and IMRT techniques, respectively. The mean ipsilateral breast V50 was 29%, 56%, and 46% (p < 0.0001) and the mean ipsilateral lung V30 was 5%, 7%, and 2% (p < 0.001 for IMRT vs. others) for the BRT, 3DCRT, and IMRT methods, respectively. For the 10 patients with left-sided breast tumors, the mean heart V5 was 12%, 4%, and 1% for the BRT, 3DCRT, and IMRT methods, respectively (p < 0.01). CONCLUSIONS: With increasing interest in PBI, our data may help clinicians individualize patient treatment decisions.  相似文献   

20.
《Medical Dosimetry》2014,39(3):227-234
The 3-dimensional conformal radiotherapy (3DCRT) technique is the standard for breast cancer radiotherapy. During treatment planning, not only the coverage of the planning target volume (PTV) but also the minimization of the dose to critical structures, such as the lung, heart, and contralateral breast tissue, need to be considered. Because of the complexity and variations of patient anatomy, more advanced radiotherapy techniques are sometimes desired to better meet the planning goals. In this study, we evaluated external-beam radiation treatment techniques for left breast cancer using various delivery platforms: fixed-field including TomoDirect (TD), static intensity-modulated radiotherapy (sIMRT), and rotational radiotherapy including Elekta volumetric-modulated arc therapy (VMAT) and tomotherapy helical (TH). A total of 10 patients with left-sided breast cancer who did or did not have positive lymph nodes and were previously treated with 3DCRT/sIMRT to the entire breast were selected, their treatment was planned with Monaco VMAT, TD, and TH. Dosimetric parameters including PTV coverage, organ-at-risk (OAR) sparing, dose-volume histograms, and target minimum/maximum/mean doses were evaluated. It is found that for plans providing comparable PTV coverage, the Elekta VMAT plans were generally more inhomogeneous than the TH and TD plans. For the cases with regional node involvement, the average mean doses administered to the heart were 9.2 (± 5.2) and 8.8 (± 3.0) Gy in the VMAT and TH plans compared with 11.9 (± 6.4) and 11.8 (± 9.2) Gy for the 3DCRT and TD plans, respectively, with slightly higher doses given to the contralateral lung or breast or both. On average, the total monitor units for VMAT plans are 11.6% of those TH plans. Our studies have shown that VMAT and TH plans offer certain dosimetric advantages over fixed-field IMRT plans for advanced breast cancer requiring regional nodal treatment. However, for early-stage breast cancer fixed-field radiotherapy is potentially more beneficial in terms of OAR sparing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号