1.
目的:探讨64排螺旋CT冠脉成像在冠心病经皮冠状动脉介入(PCI)术后诊断中的应用价值。方法:选取在我院进行治疗的冠心病PCI术后患者61例(103枚支架),分别进行64排螺旋CT冠脉成像检查和常规冠状动脉造影检查,并以冠状动脉造影结果为金标准,分析其诊断的敏感性、特异性、阳性预测值、阴性预测值及准确性。结果:64排螺旋CT冠脉成像共显示103枚支架,其诊断支架内再狭窄阳性的敏感性为88.89%,特异性95.29%,阳性预测值80.00%,阴性预测值97.59%,准确性94.17%。结论:给予冠心病PCI术后患者64排螺旋CT冠脉成像诊断支架内再狭窄的准确性、特异性及敏感性较高,可判断冠心病PCI术后患者预后情况。  相似文献   

2.
目的:分析64排128层螺旋CT在冠状动脉病变中的应用价值。方法:回顾性分析2017年3月至2018年6月期间在本院接受64排128层螺旋CT及冠状动脉造影成像检查的疑似冠状动脉疾病患者86例临床资料。所有患者均行64排128层螺旋CT及冠状动脉造影检查。以冠状动脉造影检查结果为金标准,分析64排128层螺旋CT诊断的准确度、特异性、敏感性、阴性预测值及阳性预测值。结果:经冠状动脉造影检查结果显示,57例患者存在冠状动脉病变;64排128层螺旋CT检查动脉狭窄准确度为92.79%、特异性93.46%、敏感性91.55%、阴性预测值95.29%、阳性预测值88.44%。结论:64排128层螺旋CT诊断冠状动脉病病变具有较高的诊断准确度、特异性、敏感性、阴性预测值及阳性预测值,可有效作为临床冠状动脉病变的筛查方法。  相似文献   

3.
目的:比较64排螺旋CT(64SCTCA)冠状动脉成像和冠状动脉造影对冠心病的诊断价值。方法:对36例患者均采用64SCTCA与选择性冠状动脉造影检查分析冠状动脉,并进行对比分析。结果:64SCTCA诊断冠状动脉病变的敏感性为85%,特异性为89%,阳性预测值85%,阴性预测值91%。结论:64SCTCA作为无创的检查在显示冠状动脉病变时,具有较高的敏感性和特异性,对于预测及早期诊断冠心病,有重要的临床应用价值。  相似文献   

4.
目的:探讨冠脉血管狭窄程度诊断中应用64排螺旋CT(CTA)的敏感性和特异性。方法:选取疑似冠心病患者202例,全部患者均接受64排螺旋CT与冠状动脉造影检查,以冠状动脉造影检查作为金标准,分析64排螺旋CT诊断冠脉血管狭窄程度的效果。结果:本组202例患者中,冠脉造影检查显示阳性156例,阴性46例,64排CTA检查显示阳性170例,阴性32例,CTA诊断冠脉狭窄的检出率与冠脉造影检查差异无统计学意义(P>0.05);202例患者共检测血管节段2626段,在评估时各级狭窄均出现高估或低估的情况,64排螺旋CT诊断冠脉血管狭窄随着狭窄程度增加,敏感、特异性与阳性预测值逐渐升高(P<0.05)。结论:冠脉血管狭窄程度诊断中应用64排螺旋CT的敏感性和特异性高,可使冠脉狭窄得到准确诊断,为后续治疗提供参考。  相似文献   

5.
目的通过与同期选择性冠状动脉造影对照,评价64排128层螺旋CT冠脉成像对冠状动脉疾病的诊断价值与冠状动脉支架术后的疗效判断。方法选自临床怀疑或诊断冠心病的非选择性连续患者81例行64排128层螺旋CT冠状动脉成像及选择性冠状动脉造影检查。其中临床怀疑冠心病63例,冠状动脉内置入支架18例;以冠状动脉造影结果为标准,评价64排128层螺旋CT对冠心病的诊断价值。评价结果以敏感度、特异度、阳性预测值、阴性预测值和诊断准确度来描述。结果临床怀疑冠心病63例受检者,基于冠状动脉血管节段数评价,64排128层螺旋CT诊断冠状动脉病变的敏感度为90%,特异度为97%,阳性预测值为87%,阴性预测值为98%,准确度为96%。以选择性冠状动脉造影结果为标准,64排128层螺旋CT对中度及以上(≥50%)冠状动脉狭窄诊断的敏感度为90.5%,特异度为96.6%,阳性预测值为85.9%,阴性预测值为97.8%,准确度为95.4%。对重度(≥75%)冠状动脉狭窄诊断的敏感度为93.5%,特异度为98.9%,阳性预测值为87.9%,阴性预测值为99.4%,准确度为98.4%。在18例支架置入术患者中,共置入28枚支架,能满足影像学评价为25枚,占89%。64排128层螺旋CT诊断支架再狭窄的敏感度为100%,特异度为90%,阳性预测值为71%,阴性预测值为100%,准确度为92%。结论 64排128层螺旋CT对冠状动脉狭窄有较高的诊断价值,并对冠状动脉支架的形态及有无再狭窄能作出良好评价,可作为冠心病筛查及支架置入术后随访的手段。  相似文献   

6.
目的探讨64排螺旋CT冠状动脉成像的临床应用价值。方法对122例行冠状动脉CTA检查者采用多种后处理方法重建图像,回顾性分析总结64排螺旋CT冠状动脉成像诊断冠心病的临床价值。结果发现不同类型粥样斑块310处;并与同期的常规冠状动脉造影对照了14例147节段,统计学结果为:64排螺旋CT冠状动脉成像诊断管腔内径狭窄≥50%的敏感性95.5%,特异性92.2%,阴性预测值97.9%,阳性预测值82.7%。总符合率93.2%。结论 64排螺旋CT冠状动脉成像是冠心病的有效筛查手段,具有较高的临床应用价值,是常规冠状动脉造影的重要补充。  相似文献   

7.
心率对64层螺旋CT冠状动脉造影诊断准确性的影响   总被引:1,自引:0,他引:1  
目的 评价心率对64层螺旋CT诊断冠状动脉狭窄准确性的影响.方法 对148例临床怀疑或确诊为冠心病的患者进行64层螺旋CT冠状动脉造影(CTCA)检查,将结果与传统冠状动脉造影(CCA)结果进行对照.入选患者按照心率不同分为3组:第一组为心率≤65次/分,第二组心率为66~75次/分,第三组为心率>75次/分.结果 64层螺旋CT诊断冠状动脉狭窄≥50%的敏感性为89.75%,特异性为98.63%,阳性预测值为92.33%,阴性预测值为98.12%;诊断冠状动脉狭窄≥75%的敏感性为90.22%,特异性为99.21%,阳性预测值91.71%,阴性预测值99.05%.在不同心率组中,第一组诊断狭窄≥50%的敏感性为94.55%,特异性为98.80%,阳性预测值为95.50%,阴性预测值为98.54%.第二组诊断≥50%狭窄的敏感性为90.48%,特异性为98.43%,阳性预测值为87.69%,阴性预测值为98.82%.第三组诊断≥50%狭窄的敏感性为71.93%,特异性为95.91%,阳性预测值为67.21%,阴性预测值为96.70%.结论 64层螺旋CT对心率较慢的患者有较高的准确性,可作为临床无创筛查冠心病的有效手段.  相似文献   

8.
目的比较64层螺旋CT冠状动脉成像与冠状动脉造影诊断冠心病的价值。方法选择冠心病患者120例,所有患者均接受64排螺旋CT冠状动脉成像及冠状动脉造影检查,比较两种检查方法对冠状动脉狭窄的显示情况及其敏感性、特异性、阳性预测率及阴性预测率。结果 (1)以冠状动脉造影为标准,64排螺旋CT冠脉成像显示的轻度冠脉狭窄数量较多,而中度及重度冠脉狭窄的数量较少,经统计学分析,两种检查方法间无统计学差异(P>0.05)。(2)依照冠脉造影的标准,64排螺旋CT冠脉成像对冠状动脉狭窄(≥50%)诊断的敏感性及特异性为96.4%(137/142)和96.8%(274/283),阳性预测率及阴性预测率为93.8%(137/146)和98.2%(274/279)。结论 64排螺旋CT在冠脉病变的诊断中具有较高的敏感性、特异性、阳性预测率和阴性预测率。  相似文献   

9.
目的:比较16层螺旋cT诊断冠状动脉狭窄的准确性。方法:对64例患者行16层CT冠状动脉血管成像和冠状动脉造影,计算出16层CT对冠状动脉狭窄的诊断准确性。结果:16层CT诊断冠状动脉狭窄的敏感性为86.19%,特异性为95.2%,阳性预测值为82.54%,阴性预测值96,32%。结论:16层螺旋CT冠状动脉成像对翘心病患者具有较好的诊断价值。  相似文献   

10.
目的:探讨螺旋CT冠状动脉成像对2型糖尿病的冠状动脉病变的诊断价值。方法:选取2014年5月至2017年5月东莞东华医院收治的172例存在冠状动脉病变的2型糖尿病患者,以冠状动脉造影作为检查的金标准,同时对全部患者均开展螺旋CT检查,比较两种检查方法的检查结果。结果:经过相应方法检查可知,两种检查方式的检查准确率差异无统计学意义(P0.05);64排螺旋CT显示多排螺旋CT血管造影诊断冠状动脉狭窄的敏感性,特异性,阳性预测值以及阴性预测值均较高。结论:螺旋CT冠状动脉成像对2型糖尿病的冠状动脉病变的诊断价值较高,同时其检查无创,可在临床上推广应用。  相似文献   

11.
背景:近年来,非体外循环冠状动脉旁路移植后桥血管通畅率是否与传统的体外循环冠状动脉旁路移植相同存在争议。目的:探讨体外循环与非体外循环冠状动脉旁路移植后桥血管时间通畅率的差异性。方法:选取同一操作者行体外循环冠状动脉旁路移植患者100例,按其临床特征及桥血管病变危险因素匹配抽取非体外循环冠状动脉旁路移植患者137例。采用64排多螺旋CT血管造影分析冠脉搭桥后1个月,1年,2年,3年,4年的桥血管通畅情况。结果与结论:共对641条桥血管进行评价,两组中左侧乳内动脉桥血管时间通畅率均高于大隐静脉桥,两组左侧乳内动脉桥和大隐静脉桥血管时间通畅率比较差异均无显著性意义。说明非体外循环与体外循环冠状动脉旁路移植后患者桥血管时间通畅率相似,对于某些适当的患者来说,非体外循环冠状动脉旁路移植不失为一个良好的选择。  相似文献   

12.
多层螺旋CT对冠状动脉桥血管的评价   总被引:5,自引:0,他引:5  
目的 评价16层螺旋CT在冠状动脉搭桥术后随访中的价值。方法 8例冠状动脉搭桥术后患者行心电门控下16层螺旋CT冠状动脉成像。原始数据传至工作站,进行容积再现(VRT)、最大密度投影(MIP)、曲面重建(CPR)和仿真内窥镜(CTVE)等后处理,观察桥血管位置、管腔通畅情况。结果 在CT图像上,8例患者的12根桥血管均可用于评价,并且未发现明显再狭窄和闭塞。结论 16层螺旋CT可无创性对冠状动脉桥血管进行评价。  相似文献   

13.
The left internal thoracic artery (LITA) undergoes vascular remodelling when used for coronary artery bypass grafting. In this study we tested the hypothesis that the extent of the LITA remodelling late after coronary artery bypass grafting assessed by multidetector computed tomography is related to the severity of stenosis in the native coronary vessel. One hundred and forty-two patients who had undergone coronary artery bypass grafting including implantation of LITA as conduit to the left anterior descending artery were studied 5 years after surgery. Arterial graft patency and geometry was assessed with 64-slice multidetector computed tomography. Quantitative volumetric assessment of the LITA was performed to measure the average vessel lumen area (mm2/m2). The native coronary vessel subtended by the LITA was evaluated by multidetector computed tomography and defined as a high-grade stenosis patient group, when the diameter stenosis was >70% and an intermediate grade stenosis patient group when <70%. Among patients with intermediate-grade stenosis of the native vessel 11 out of 65 patients (17%) had a totally occluded LITA, as opposed to none among the 77 patients with a high-grade stenosis. In patients with intermediate-grade stenosis of the proximal native vessel, the LITA lumen area was 4.9 compared to 5.3 mm2/m2 in patients with a high-grade stenosis of the proximal native vessel (P = 0.0043). Lumen area of the LITA when used as a conduit in patients with coronary artery disease seems to be inversely correlated with the severity of disease in the native coronary vessel proximal to the anastomosis. Volumetric vessel multidetector computed tomography appears to be useful for evaluation of coronary bypass remodelling.  相似文献   

14.
64层螺旋CT在评价冠状动脉桥血管中的价值   总被引:1,自引:0,他引:1       下载免费PDF全文
目的探讨64层螺旋CT在诊断冠状动脉桥血管的临床价值。方法对21例冠状动脉搭桥术的患者行64层螺旋CT心、胸部血管造影检查。对所有扫描原始数据行冠状、矢状MPR、曲面重建(CPR)以及VR、MIP重建。由两位有经验的放射科医生对所有图像进行观察,对桥血管狭窄进行诊断,并评价其狭窄程度。8例CT诊断桥血管重度狭窄(管腔狭窄>75%)或闭塞的患者同时行选择性血管造影检查。结果21例患者均可清晰地显示冠状动脉各主要分支,并能清晰地显示其斑块和管腔的狭窄。21例患者经螺旋CT心、胸部血管造影检查,可清晰显示52条桥血管,其中13条桥血管出现再狭窄(10条为大隐静脉桥血管,3条为乳内动脉桥血管),狭窄部位均位于桥血管吻合口处;重度狭窄7条,闭塞1条,此8条桥血管均与选择性血管的结果相吻合,CT评价冠状动脉桥血管重度狭窄的准确性为100%。结论64层螺旋CT心、胸血管造影检查不但能显示冠状动脉桥血管,而且能清晰地显示原始的冠状动脉及冠状动脉与桥血管的吻合口,是评价冠状动脉桥血管的一种有效的可靠的检查方法。  相似文献   

15.
目的:探讨64排螺旋CT在冠状动脉旁路移植患者术后随访中的价值。方法:对52例接受冠状动脉旁路移植患者作螺旋CT检查,进行血管重建,对部分患者同期进行冠状动脉造影检查,结合临床症状对螺旋CT成像结果进行分析。结果:52例患者均成功完成了冠状动脉螺旋CT检查,共有187支桥血管成像,其中乳内动脉移植血管50支,静脉移植血管129支,桡动脉移植血管8支。50支乳内动脉移植血管中,6支有不同程度狭窄;129支静脉移植血管中,48支有不同程度狭窄;8支桡动脉桥中2支有不同程度狭窄。本组患者中有28例患者同期作了冠状动脉造影,共检出105支移植血管血管,造影结果与CT检查结果基本相符,螺旋CT检查假阳性率为4.4%,假阴性率为2.7%。检出有移植血管血管病变的27例患者中,22例有临床症状;另有3例有症状的患者,螺旋CT检查未发现有异常。结论:作为一种微创伤检查方法,64排螺旋CT是冠状动脉旁路移植患者术后随访的理想的方法。  相似文献   

16.
目的:评价64层螺旋CT冠状动脉血管成像(CTA)在诊断各种类型冠状动脉变异中的价值和临床应用。方法:回顾性分析617例行冠状动脉CTA检测患者的冠状动脉变异检出率,并根据CT结果对冠状动脉变异进行分类。结果:617例冠状动脉CTA受检者中,共检出冠状动脉变异78例(12.64%,78/617),其中右冠状动脉起自主动脉左冠状窦者9例,左冠状动脉起自主动脉右冠状窦者2例,右冠状动脉开口高位者2例,多开口变异者2例(并行左主干),心肌桥者59例.前降支.肺动脉瘘者2例,左右冠状动脉一肺动脉瘘者l例,右冠状动脉一左室瘘合并右冠状动脉瘤者1例。结论:冠状动脉CTA能准确评估冠状动脉变异,并可清晰显示各类病变细节,可作为无创性诊断冠状动脉变异的首选方法。  相似文献   

17.
目的:通过对64排螺旋CT(MSCT)冠状动脉造影与选择性冠状动脉造影检测冠状动脉病变(冠状动脉狭窄≥50%)的对比分析,探讨64层螺旋CT评估冠状动脉病变诊断的准确性。方法:回顾性收集2007年12月~2008年10月于我院同期接受64层螺旋CT冠状动脉成像和常规经皮冠脉造影的112位冠心病患者的影像资料,以常规冠脉造影为参考标准,对2种检查方法的结果进行对比分析,评估64层螺旋CT冠脉造影对冠状动脉病变诊断的准确性。结果:按常规冠脉造影计算,112例患者共发现374处病变用于评价,MSCT造影检测冠脉病变总的准确性为90.6%,假阳性率和假阴性率分别为4.3%和5.1%;其中MSCT检测为假阴性均发生在左回旋支和右冠远段,假阳性均为冠状动脉伴有钙化。结论:64排螺CT冠状动脉造影检测冠状动脉病变诊断的准确性较高,但血管解剖和冠状动脉钙化可能会影响其对冠状动脉病变的评价和检测。  相似文献   

18.
Recurrent cardiac ischemia after coronary artery bypass graft surgery occurs in a significant proportion of patients, prompting repeat investigations and incurring significant clinical and financial costs. Noninvasive investigations to identify graft occlusion and quantify graft stenosis are desirable due to the complications, cost, and patient inconvenience of invasive coronary angiography. The increasing use of 64-slice multislice computed tomography has led to multiple reports on its accuracy in graft stenosis and occlusion. This review focuses on image acquisition and manipulation techniques, interpretative pitfalls, and the diagnostic performance of 64-slice multislice computed tomography in coronary artery bypass graft imaging across the medical literature.  相似文献   

19.
目的 评价64层螺旋CT冠状动脉成像(coronary 64-slice computed tomographic angiography,64S-CCTA)在诊断冠状动脉疾病(CAD)中的临床应用价值.方法 回顾性分析92例行64S-CCTA患者完整资料,并以近期(2周之内)实施的X线冠状动脉造影检查(coronary artery disease,CAG)结果为金标准进行对比.结果 所有可用于评估1,129段冠脉中,64S-CCTA显示轻度和明显狭窄病变各为122、231段,其中各有61、198段得到CAG证实;64S-CCTA判断冠状动脉明显狭窄的灵敏度、特异度、阳性预测值、阴性预测值、阳性似然比、阴性似然比分别为88.39%、96.35%、85.71%、97.10%及24.22、0.12;在CAG确诊狭窄节段中,64S-CCTA在轻度狭窄和明显狭窄中分别检测出非钙化性斑块、钙化斑块各为32、65 和154、53个.结论 64S-CCTA是一种简便、可靠的无创性检查方法,对病变血管管腔狭窄及不同性质粥样硬化斑块与狭窄关系的评价有一定价值,可作为临床拟诊冠心病患者筛查的有效手段.  相似文献   

20.
This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic modality were compared to the findings of traditional coronary angiography. In the first patient MDCT showed occlusion of the left internal mammary artery (LIMA) and saphenous vein graft after the second anastomosis. Coronary angiography confirmed these findings. In the second patient EBT showed patency of the LIMA and saphenous vein graft. After the first anastomosis of the saphenous vein graft, the connected vessel filled poorly. Coronary angiography confirmed both grafts to be patent, and detected an occlusion distal to the first anastomosis. These findings support the evidence that both MDCT and EBT are suitable techniques for establishing bypass graft patency by non-invasive means.  相似文献   