首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
《Acta orthopaedica》2013,84(5):427-432
Background and purpose — Straight collarless polished tapered stems have been linked to an increased risk for periprosthetic femur fractures in comparison with anatomically shaped stems, especially in elderly patients. Therefore, we evaluated the effect of an orthopedic department’s full transition from the use of a cemented collarless, polished, tapered stem to a cemented anatomic stem on the cumulative incidence of postoperative periprosthetic fracture (PPF).

Patients and methods — This prospective single-center cohort study comprises a consecutive series of 1,077 patients who underwent a cemented hip arthroplasty using either a collarless polished tapered stem (PTS group, n = 543) or an anatomic stem (AS group, n = 534). We assessed the incidence of PPF 2 years postoperatively and used a Cox regression model adjusted for age, sex, ASA class, cognitive impairment, BMI, diagnosis, and surgical approach for outcome analysis.

Results — Mean age at primary surgery was 82 years (49–102), 73% of the patients were female, and 75% underwent surgery for a femoral neck fracture. The PPF rate was lowered from 3.3% (n = 18) in the PTS group to 0.4% (n = 2) in the AS group. The overall complication rate was also lowered from 8.8% in the PTS group to 4.5% in the AS group. In the regression model only cognitive dysfunction (HR 3.8, 95% CI 1.4–10) and the type of stem (PTS vs AS, HR 0.1, CI 0.0–0.5) were correlated with outcome.

Interpretation — For elderly patients with poor bone quality use of cemented anatomic stems leads to a substantial reduction in periprosthetic fracture rate without increasing other complications.  相似文献   

2.

Background

Cemented stems are designed to follow 1 of 2 principles of fixation: composite beams or slide taper. Stems in the latter category have a collarless, polished, tapered (CPT) design and subside into the cement mantle, creating hoop stresses. We compared the rate of periprosthetic fracture (PPF) of stem designed with these 2 principles of fixation. In addition, we examined radiographic factors that may predispose to the development of PPF.

Methods

We retrospectively reviewed all patients who underwent primary THA by a single surgeon using highly polished cemented stems. PPF rates were compared between CPT stems (follow-up, 21 months; standard deviation [SD], 22) and composite beam stems (follow-up, 21.7 months; SD, 26). Demographic data were compared between patients with and without a PPF. Three preoperative radiographic parameters (canal bone ratio [CBR], canal-calcar ratio, and canal flare index), stem alignment, and cement mantle were compared in match-paired patients with and without a PPF (1:34).

Results

Seven of 1460 THA patients developed a PPF (0.479%); 4 hips of 185 with a CPT stem (2.2%); and 3 of 1275 hips with a composite beam stem (0.23%; P = .0064). Three of the 4 PPFs in the CPT group and none in the composite beam group were classified as Vancouver B2. The CBR in patients with a PPF was 0.50 (SD, 0.07) and 0.43 (SD, 0.07) in the match cohort of hips without PPF (P = .013).

Conclusion

CPT stems may be associated with a higher risk of PPF that often require reoperation. An increased CBR may be a risk factor for postoperative PPF.  相似文献   

3.
4.
BackgroundUncemented hemiarthroplasty (UHA) for displaced femoral neck fracture (FNF) is favored by some surgeons because of the reduced rate of perioperative mortality and operative time. However higher rates of intraoperative and postoperative periprosthetic fractures (PPFs) have been reported. The aim of the study was to review day-0, day-1, day-2, day-30, and one-year mortality as well as intraoperative and postoperative PPF after UHA for displaced FNF and compare this with cemented hemiarthroplasties (CHAs) performed. Secondary objectives were to assess whether femoral stem geometry and alignment were associated with PPF in UHA.MethodsA retrospective observational study was conducted of patients treated with a hemiarthroplasty for a displaced FNF over an eleven-year period. Radiographic analysis was conducted of femoral geometry and stem alignment.ResultsOver the 11-year study period, 857 UHAs and 247 CHAs were performed. There were no on-table, day-0, day-1, or day-2 deaths in UHA. Intraoperative PPF occurred in 3.6% UHA and 2% CHA and postoperative PPF in 2.4% UHA and 4.8% CHA. Intraoperative PPF was not associated with increased mortality (P = .15), postoperative PPF, or all-cause revision in UHA. Valgus stem alignment was a risk factor for a postoperative PPF and additional surgery in UHA (P = .004).ConclusionUHA was associated with no perioperative deaths and a 30-day mortality rate of 5% in this series. It can be considered in patients with multiple medical comorbidities. Careful surgical planning and technique is important to optimize stem alignment particularly in Dorr C type femurs.  相似文献   

5.
Studies on patients with degenerative joint disease of the hip show that femoral periprosthetic bone mineral decreases following total hip arthroplasty. Scarcely any osteodensitometric data exist on femoral neck fracture (FNF) patients and periprosthetic bone remodelling. In two parallel cohorts we enrolled 87 patients (mean age, 72 ± 12 years; male:female ratio, 30:57) undergoing total hip arthroplasty for either primary osteoarthritis (OA) of the hip (n = 37) or for an acute FNF (n = 50) and followed them for a mean of 5.4 years. Outcomes were bone mineral density (BMD) changes in the periprosthetic Gruen zones 1–7, the incidence of periprosthetic fractures and clinical outcome. The bone mineral loss in the fracture group was more than twice that of the osteoarthritis group, ?16.9% versus ?6.8% (p = 0.004). The incidence of periprosthetic fractures was 12% (6/50) in the fracture cohort compared with none (0%) in the OA cohort (p = 0.03). Periprosthetic bone mineral loss following total hip arthroplasty is significantly greater in patients who are treated for acute FNF than in OA patients. This decrease of BMD follows a different pattern with the FNF patients losing larger proportions of bone in Gruen zones 1, 2, 6, and 7 while the OA patients tend to have larger losses only in zones 1 and 7. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:504–512, 2015.
  相似文献   

6.
《Acta orthopaedica》2013,84(4):491-497
Background?A total hip arthroplasty (THA) is often used as treatment for failed osteosynthesis of femoral neck fractures and is now also used for acute femoral neck fractures. To investigate the results of THA after femoral neck fractures, we used data from the Norwegian Arthroplasty Register (NAR).

Patients and methods?The results of primary total hip replacements in patients with acute femoral neck fractures (n = 487) and sequelae after femoral neck fractures (n = 8,090) were compared to those of total hip replacements in patients with osteoarthrosis (OA) (n = 55,109). The hips were followed for 0–18 years. The Cox multiple regression model was used to construct adjusted survival curves and to adjust for differences in sex, age, and type of cement among the diagnostic groups. Separate analyses were done on the subgroups of patients who were operated with Charnley prostheses.

Results?The survival rate of the implants after 5 years was 95% for the patients with acute fractures, 96% for the patients with sequelae after fracture, and 97% for the OA patients. With adjustment for age, sex, and type of cement, the patients with acute fractures had an increased risk of revision compared to the OA patients (RR 1.6, 95% CI: 1.0–2.6; p = 0.05) and the sequelae patients had an increased risk of revision (RR 1.3, 95% CI: 1.2–1.5; p < 0.001). Sequelae hips had higher risk of revision due to dislocation (RR 2.0, 95% CI: 1.6–2.4; p < 0.001) and periprosthetic fracture (RR 2.2, 95% CI: 1.5–3.3; p < 0.001), and lower risk of revision due to loosening of the acetabular component (RR 0.72, 95% CI; 0.57–0.93; p = 0.01) compared to the OA patients. The increased risk of revision was most apparent for the first 6 months after primary operation.

Interpretation?THA in fracture patients showed good results, but there was an increased risk of early dislocations and periprosthetic fractures compared to OA patients.  相似文献   

7.
《Acta orthopaedica》2013,84(4):396-402
Background and purpose— We previously evaluated a new uncemented femoral stem designed for elderly patients with a femoral neck fracture and found stable implant fixation and good clinical results up to 2 years postoperatively, despite substantial periprosthetic bone mineral loss. We now present the medium-term follow-up results from this study.

Patients and methods— In this observational prospective cohort study, we included 50 patients (mean age 81 (70–92) years) with a femoral neck fracture. All patients underwent surgery with a cemented cup and an uncemented stem specifically designed for fracture treatment. Outcome variables were migration of the stem measured with radiostereometry (RSA) and periprosthetic change in bone mineral density (BMD), measured with dual-energy X-ray absorptiometry (DXA). Hip function and health-related quality of life were assessed using the Harris hip score (HHS) and the EuroQol-5D (EQ-5D). DXA and RSA data were collected at regular intervals up to 4 years, and data concerning reoperations and hip-related complications were collected during a mean follow-up time of 5 (0.2–7.5) years.

Results— At 5 years, 19 patients had either passed away or were unavailable for further participation and 31 could be followed up. Of the original 50 patients, 6 patients had suffered a periprosthetic fracture, all of them sustained after the 2-year follow-up. In 19 patients, we obtained complete RSA and DXA data and no component had migrated after the 2-year follow-up. We also found a continuous total periprosthetic bone loss amounting to a median of –19% (–39 to 2). No changes in HHS or EQ-5D were observed during the follow-up period.

Interpretation— In this medium-term follow-up, the stem remained firmly fixed in bone despite considerable periprosthetic bone mineral loss. However, this bone loss might explain the high number of late-occurring periprosthetic fractures. Based on these results, we would not recommend uncemented femoral stems for the treatment of femoral neck fractures in the elderly.  相似文献   

8.
Background and purpose — The use of uncemented fixation in total hip arthroplasty (THA) is increasing. Registry studies have indicated an increased risk of revision of uncemented implants due to early periprosthetic femoral fracture. In this paper, we describe the incidence and predisposing factors for intraoperative and early postoperative (90 days) periprosthetic femoral fractures after cemented and uncemented THA.

Patients and methods — This was a prospective observational study in 8 Danish high-volume centers from February 2010 to November 2013. We used the 90-day follow-up from the Danish National Patient Registry and patient records. We obtained intraoperative information from the Danish Hip Arthroplasty Registry and from surgical notes.

Results — Of 7,169 primary consecutive THAs, 5,482 (77%) were performed using uncemented femoral components. The total incidence of periprosthetic femoral fractures90 days postoperatively was 2.1% (n = 150). 70 fractures were detected intraoperatively (46 required osteosynthesis). 51 postoperatively detected fractures occurred without trauma (42 of which were reoperated) and 29 were postoperative fall-related fractures (27 of which were reoperated). 134 fractures (2.4%) were found in uncemented femoral components and 16 (0.9%) were found in cemented femoral components (p < 0.001). Uncemented femoral stem (relative risk (RR)?=?4.1, 95% CI: 2.3–7.2), medically treated osteoporosis (RR =2.8, CI: 1.6–4.8), female sex (RR =1.6, CI: 1.1–2.2), and age (RR =1.4 per 10 years, CI: 1.2–1.6) were associated with increased risk of periprosthetic femoral fracture when analyzed using multivariable regression analysis.

Interpretation — Uncemented femoral components were associated with an increased risk of early periprosthetic femoral fractures, especially in elderly, female, and osteoporotic patients.  相似文献   

9.
Background and purpose — Long-term fixation of cemented femoral stems relies on several factors including cement adhesion and fatigue. Hi-Fatigue is a newer third-generation bone cement with low-viscosity properties at room temperature, good mechanical strength, and stable bone–cement interface in a laboratory testing environment. Palacos bone cement has excellent 10-year survival and is considered gold standard. We compared stem subsidence after fixation with Hi-Fatigue and Palacos bone cements using radiostereometry.

Patients and methods — In a patient-blinded randomized controlled trial, 52 patients (30 women) at mean age 76 years (71–87) with osteoarthrosis and no osteoporosis received Hi-Fatigue G or Palacos R?+?G cement fixation of collarless, polished, double-tapered stems (CPT). Tantalum beads were inserted in the periprosthetic bone. Supine stereoradiographs were obtained postoperatively, 3 months, 6 months, 1 year, and 2 years after surgery. Oxford Hip Score (OHS) and VAS pain were recorded preoperatively and 1 and 2 years after surgery. Cement working times and properties were registered.

Results — At 2 years, mean stem subsidence of 1.12?mm (95% CI 0.96–1.29) for Hi-Fatigue and 1.19?mm (CI 1.03–1.34) for Palacos was similar. Likewise, stem version was comparable between cement groups. Mean OHS and VAS pain were similar between cement groups.

Cement working times were similar between cement groups, but the mean curing time was longer for Hi-Fatigue (13.7?min) than for Palacos (11.6?min).

Interpretation — We found similar and generally low migration of CPT femoral stems inserted with Hi-Fatigue and Palacos bone cement until 2 years’ follow-up, which indicates a good long-term survival of polished taper femoral stems inserted with both cement types.

Trial registration: ClinicalTrials.gov identifier: NCT01289834.  相似文献   

10.
《Acta orthopaedica》2013,84(4):363-367
Purpose — We evaluated the 5-year survival of the uncemented Optan anatomically adapted femoral stem, with revision for aseptic loosening as the endpoint.

Methods — Between January 2004 and March 2007, 432 total hip arthroplasties (THAs) were performed in 432 patients. After follow-up for a mean time of 5 years, the patients were evaluated using the WOMAC questionnaire and plain radiography. Patients who were unable to attend the follow-up visit were contacted by telephone to determine whether they had had any revision surgery of their THA

Results — Within 5 years, 39 patients (9%) had died of unrelated causes and 63 patients (15%) had been lost to follow-up. Of the remaining cohort, 224 patients (68%) had full follow-up while 88 patients (27%) were evaluated with WOMAC only and 18 patients (5%) were evaluated with radiography only. The mean WOMAC score of all evaluated patients was 21 (10–100). At 5-year follow-up, there were 26 stem revisions reported (6%), 14 hips (3%) showed aseptic loosening, and 12 hips (3%) had had a periprosthetic femoral fracture. The 5-year survival to revision for any reason was 94%. Worst-case analysis yielded a 5-year survival of 79%.

Interpretation — The 5-year survival for aseptic loosening of the Optan anatomically adapted femoral component was disappointing. Radiographic evaluation showed evidence of proximal radiolucencies and distal cortical bone hypertrophy, which we attribute to insufficient proximal bone in-growth and increased load transfer at the tip of the stem. We do not recommend the use of the Optan femoral stem.  相似文献   

11.
《The Journal of arthroplasty》2020,35(4):1069-1073
BackgroundExtensive femoral bone loss poses a challenge in revision total hip arthroplasty (rTHA). Many techniques have been developed to address this problem including fully porous cylindrical stems, impaction bone grafting, and cementation of long stems, which have had varied success. Modular tapered fluted femoral stems (MTFS) show favorable results. We sought to determine the minimum 2-year radiographic and clinical performance of MTFS in rTHA in a population with extensive proximal femoral bone loss.MethodsOur clinical database was queried retrospectively for all patients who underwent rTHA with an MTFS. We included patients with Paprosky 3 and 4 femoral bone loss and patients with Vancouver B2 and B3 periprosthetic femur fractures. Patients without 2-year follow-up were invited to return to clinic for X-ray evaluation and to complete clinical questionnaires. We assessed distance of stem subsidence and presence of stem fixation on final X-ray. We recorded all-cause revision and survival of the stem at final follow-up.ResultsOne hundred twenty-nine patients were available for follow-up. Average follow-up time was 3.75 years. One hundred twenty-two stems (95%) remained in place at final follow-up. Median subsidence was 1.4 mm (range 0-21). All-cause revision rate was 16.3% (21 patients). Of the hips revised, 10 were for instability, 6 for infection, 1 for aseptic loosening, and 1 for periprosthetic femur fracture. Three were revised for other reasons. The stem was revised in 7 patients (5.4%), and the most common reason for stem revision was infection (5 patients). The other 2 stems were revised for aseptic loosening in a Paprosky 4 femur and periprosthetic femur fracture. Survival of tapered modular fluted stems with aseptic failure as an endpoint was 98.4%. The mean Hip disability and Osteoarthritis Outcome Score, Joint Replacement score at final follow-up was 73, and mean Veterans Rand 12 item health survey physical and mental scores were 32.8 and 52.2, respectively.ConclusionIn patients with Paprosky 3, 4 femoral defects or Vancouver type B2, B3 fractures, modular tapered fluted stems for femoral revision show excellent outcomes at minimum 2-year follow-up.  相似文献   

12.
《The Journal of arthroplasty》2020,35(6):1708-1711
BackgroundPeriprosthetic fracture remains a major source of reoperation following total hip arthroplasty (THA). Within 90 days of surgery, fractures may occur spontaneously or with minor injury and are therefore more likely related to patient factors including anatomic variation.MethodsFrom 2008 to 2018, 16,254 primary THAs were performed at our institution; of those, 48 were revised for periprosthetic fracture within 90 days of surgery. A control group of 193 patients undergoing THA for hip osteoarthritis (OA) was randomly selected from the source population. We excluded patients with genetic bone disease and THA performed for hip fracture. We used logistic regression to analyze associations between patient factors (demographics, anatomical factors, comorbidities, surgical technique, and implants) and odds of 90-day periprosthetic fracture.ResultsIncreased age was significantly associated with fracture (P = .002), as was female gender (P = .046). After adjusting for age and gender, absence of contralateral OA was associated with increased odds of fracture relative to patients with contralateral OA (odds ratio [OR] 3.85, 95% confidence interval [CI] 1.60-9.29), as was having a contralateral THA in place (OR 3.70, 95% CI 1.59-8.60). The neck-shaft angle, femoral offset, and the Dorr classification were not associated with increased odds of fracture. Additionally, the distance from the tip of the trochanter to the top of the femoral head was associated with increased odds of fracture per half centimeter (OR 1.48, 95% CI 1.14-1.93).ConclusionRisk of early postoperative periprosthetic fracture following THA is increased with age, female gender, and increasing distance from the greater trochanter to the top of the femoral head; and decreased in the setting of contralateral hip OA. The trochanter-head distance correlation with periprosthetic hip fracture indicates that the preoperative anatomy may influence PPF, particularly regarding how that anatomy is reconstructed.  相似文献   

13.
We evaluated the clinical and radiographic results of the first consecutive 154 implantations of a cementless, double-tapered straight femoral stem (cementless Spotorno (CLS), Sulzer Orthopedics) in 141 patients under the age of 55 (mean 47 (13–55)) years. After a mean follow-up of 12 (10–15) years, 11 patients (11 hips) had died and 7 (7 hips) could not be located. 5 patients (5 hips) underwent femoral revision—1 for infection, 1 for periprosthetic fracture and 3 for aseptic loosening of the stem. The overall survival rate of the stem was 97% at 12 years (95% confidence limits, 93%–100%), and survival with femoral revision for aseptic loosening as an end point 98 (95–100)%. The survival rate of the acetabular components was 78 (71–85) % after 12 years. The median Harris hip score at follow-up was 84 points. None of the patients had thigh pain. Radiolucent lines in Gruen regions 1 and 7 were present in 21 hips (17%). 2 hips had radiolucent lines in regions 2–6 on anteroposterior (AP) radiographs. No femoral osteolysis was detected.

The mid- to long-term survival with this type of femoral component is excellent and compares favorably with cemented stems in this age group. However, the high rate of cup loosening and the low Harris hip scores are a concern in this subgroup of young patients.  相似文献   

14.
We report the results of impaction bone grafting of the femoral side in revision total hip arthroplasty in Asian hips (South Korean patients) in which the surgery was performed with the use of the Exeter stem. The minimum follow-up was 39 months (mean, 48.4; range, 39-66). There was subsidence of the cement-graft interface (<1 mm) in three hips (5%), of the stem-cement interface (<1 mm) in 12 hips (21%) and of the stem-cement interface (1-2 mm) in 14 hips (25%). Five hips (9%) developed intraoperative femoral fracture and two hips (4%) femoral perforation in revision. The complications of femoral fracture and subsidence did not have an adverse effect on the final clinical outcomes. The impaction of fresh-frozen allograft and use of a cemented, polished, tapered stem (Exeter stem) were also successful with good clinical and radiographic outcomes in our study of Asian hips (South Korean patients). However, we used smaller stems than the usual ones used for Western patients because of the smaller femur sizes.  相似文献   

15.
16.
《Acta orthopaedica》2013,84(4):427-435
Background and purpose We have developed an individually designed, uncemented femoral component for achievement of improved strain distribution and fixation to the bone, to make uncemented stems more applicable in femurs of abnormal size and shape, and to improve the joint mechanics. Here we describe the design of the implant and present the results of a prospective clinical study with at least 7 years of follow-up.

Patients and methods The prostheses are produced by CAD-CAM technique. The design of the stem is based on CT information, and the neck design is based on the surgeon's planning of the center of rotation, femoral head offset, and leg length correction. The first-generation stem produced before 2001 had a proximal HA coating and a sand-blasted distal part that was down-scaled to avoid contact with compact bone. The second-generation stem had a porous coating beneath the HA layer and the distal part of the stem was polished.

The implant was used in 762 hips (614 patients) from 1995 until 2009. 191 of these hips were followed for 7 years and 83 others were followed for 10 years, and these hips are included in the present study. Mean age at surgery was 48 (20–65) years. Congenital dysplasia of the hip was the reason for osteoarthritis in 46% and 57% of the hips in respective groups. Merle d'Aubigné score was recorded in 152 and 75 hips in the two groups. Prostheses followed for 10 years, and almost all in the 7-year group, were first-generation stems.

Results The 7- and 10-year cumulative revision rates were 1.1% and 2.4%, respectively, with stem revision for any reason as endpoint. The clinical results were similar at 7 and 10 years, with Merle d'Aubigné scores of 17. Intraoperative trochanteric fissures occurred in 2 of the 191 operations (1.0%); both healed after wiring. In hips followed for 7 years, 2 periprosthetic fractures occurred; exchange of the stem was necessary in both. One additional fracture occurred between 7 and 10 years, and it was treated successfully with osteosynthesis. The rate of dislocation was 1.6% and 2.4%, respectively. There was no radiographic loosening at follow-up.

Interpretation Use of a custom femoral stem gives a reliable fixation and promising medium-term clinical results in femurs of normal and abnormal shape and dimension. The individual design, which enables optimized joint mechanics, gives a low risk of mechanical complications.  相似文献   

17.
We prospectively followed 191 consecutive collarless polished tapered (CPT) femoral stems, implanted in 175 patients who had a mean age at operation of 64.5 years (21 to 85). At a mean follow-up of 15.9 years (14 to 17.5), 86 patients (95 hips) were still alive. The fate of all original stems is known. The 16-year survivorship with re-operation for any reason was 80.7% (95% confidence interval 72 to 89.4). There was no loss to follow-up, with clinical data available on all 95 hips and radiological assessment performed on 90 hips (95%). At latest follow-up, the mean Harris hip score was 78 (28 to 100) and the mean Oxford hip score was 36 (15 to 48). Stems subsided within the cement mantle, with a mean subsidence of 2.1 mm (0.4 to 19.2). Among the original cohort, only one stem (0.5%) has been revised due to aseptic loosening. In total seven stems were revised for any cause, of which four revisions were required for infection following revision of the acetabular component. A total of 21?patients (11%) required some sort of revision procedure; all except three of these resulted from failure of the acetabular component. Cemented acetabular components had a significantly lower revision burden (three hips, 2.7%) than Harris Galante uncemented components (17 hips, 21.8%) (p < 0.001). The CPT stem continues to provide excellent radiological and clinical outcomes at 15?years following implantation. Its results are consistent with other polished tapered stem designs.  相似文献   

18.
Background and purpose — The loss of bone mineral in the proximal femur following hip arthroplasty may increase the fracture risk around uncemented stems. We hypothesized that the surgical approach to the hip might influence bone mineral changes around the femoral stem in patients with a femoral neck fracture (FNF).

Patients and methods — This was a pre-specified subgroup analysis (n = 51) of an ongoing randomized trial (n = 120) in patients with FNF. Participants were allocated to an uncemented hemiarthroplasty inserted through a direct lateral (Hardinge) approach or an anterolateral (modified Watson-Jones) approach. The 51 patients (mean age 83 (70–90) years, 33 women) were measured by dual-energy X-ray absorptiometry (DXA) to assess changes in periprosthetic bone mineral density (BMD).

Results — The mean change in total BMD differed between groups at 12 months in favor of the anterolateral group (4.8%, 95% CI 0.0–9.6; p = 0.05). DXA at 3 months displayed BMD loss in the proximal Gruen zones in the lateral group compared with the anterolateral group. Zone 1 (–5.0% vs. 2.7%), zone 2 (–4.3% vs. 4.1%), zone 6 (–6.5% vs. 0.0%) and zone 7 (–11% vs. –2.4%, all p < 0.05).

Interpretation — DXA measurements in this study indicate that surgical approach to the hip influences periprosthetic BMD. Clinical implications remain uncertain. Our conclusions should be interpreted with caution as we did not perform adjustments for multiple tests, possibly leading to inflation of false-positive findings.  相似文献   


19.
The purpose of this study was to evaluate the osseointegration potential and implant-related complications of cementless total hip arthroplasty with a titanium alloy collarless, tapered, wedge-shaped femoral stem with a proximal circumferential plasma-spray coating in patients with acute hip fractures. The cohort consists of 85 patients with a mean age of 78.1 years. The mean duration of follow-up was 3.8 years. Total hip arthroplasty conferred significant improvement in function for all patients. All femoral components were stable with evidence of bone ingrowth (84 hips) or fibrous fixation (1 hip). Mild thigh pain was present in 3 patients. The complications included dislocation (3 cases), intraoperative femoral fracture (2 cases), and periprosthetic femoral fracture in the postoperative period (1 case). There was one reoperation for revision of the femoral component in the patient with a periprosthetic fracture. There were 25 (29%) deaths. Cementless total hip arthroplasty using a tapered proximally coated femoral stem is a viable option for the treatment of a displaced hip fracture and preexistent arthritis.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号