首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
目的 探讨药物洗脱支架(DES)置入术后晚期支架贴壁不良的特点.方法 分析32例(包括51支血管、共置入71个支架)置入DES 1年后[(14.8±5.2)个月]行光学相干断层成像(OCT)检查的患者资料,对支架节段的OCT图像每间隔0.5 mm取1帧图像进行分析,找出贴壁不良的支架金属结构,测量支架到参照血管内壁的距离及支架表面内膜厚度,分析晚期支架贴壁不良的特点.结果 OCT检查在7例(21.9%)患者中检出支架贴壁不良,其中4例合并支架段血管的正性重构,1例重叠置入支架,2例发现由血栓覆盖支架金属结构,7例患者随访期间无心脏不良事件发生.97.6%的支架金属结构完全贴壁并不同程度的内膜覆盖,2.4%的支架金属结构贴壁不良,包括1.2%的支架金属结构位于血管分支开口.位于血管分支开口的支架金属结构与其他贴壁不良支架表面的内膜覆盖厚度差异无统计学意义[(0.06±0.05)mm比(0.05±0.03)mm,P>0.05].绪论晚期支架贴壁不良见于DES置入最初的贴壁不良、血管壁正性重构、重叠置入支架以及支架金属结构位于分支血管开口;贴壁不良的支架金属结构表面亦有不同程度的内膜覆盖.  相似文献   

2.
Background: Using optical coherence tomography (OCT), we evaluated the relationship between malapposed and uncovered struts following implantation of drug‐eluting stents (DESs). Methods: A total of 271 patients with 306 lesions who underwent DES implantation and follow‐up OCT were included in the study. The lesions were grouped based on the presence of malapposition and then by the median value of the percentage of malapposed struts (1.3%) to produce 3 groups: lesions without malapposition (group I, n = 232) and those with percentage of malapposed struts <1.3% (group II, n = 37) or ≥1.3% (group III, n = 37). Percentages of malapposed and uncovered struts were calculated as percent ratio of malapposed or uncovered to total struts in the defined cross‐sections, respectively. We compared percentage of uncovered struts in all analyzable struts and in the residual struts without malapposed segments among the 3 groups. Results: Group III showed a significantly larger percentage of uncovered struts among all the struts (group I, 3.7 ± 6.4 vs. II, 5.5 ± 5.6 vs. III, 17.6 ± 15.9%, P < 0.001) and among residual struts without malapposed segments (3.7 ± 6.4 vs. 5.2 ± 5.7 vs. 15.0 ± 14.4%, respectively, P < 0.001). There was a significant correlation between malapposed and uncovered struts in group III (r = 0.393, P = 0.016), but not in group II (r =?0.007, P = 0.965) among residual struts without malapposed segments. Conclusion: The percentage of uncovered DES struts was quite different depending on the presence and extent of malapposed struts. (J Interven Cardiol 2012;25:270–277)  相似文献   

3.

Objectives

Prospective optical coherence tomography (OCT) study of strut apposition and neointimal hyperplasia thickness (NIH) of a paclitaxel eluting stent (PES), (Infinium, Sahajanand Medical Technologies Pvt Ltd.).

Background

Few data exist concerning neointimal coverage of PES. Uncovered and malapposed struts are more common following stenting in acute coronary syndromes (ACS) than in non-ACS lesions.

Methods

All consecutive patients with ACS, treated with the above PES for single native coronary lesions between August 2008 and January 2009, who consented to invasive follow-up with OCT at six months (N = 13), were included.

Results

At 6 months no patient demonstrated angiographic restenosis. 3180 struts from 20 stents were analyzed, and 91.3% were covered with neointima (NIH 204.8 ± 159.5 μm). Standard statistics and least squares estimates (LSE) derived from a hierarchical ANCOVA model to take into account clustering effects are presented. Rate of uncovered struts was 8.6%, LSE 7.39 (95% CI 3.05-11.73), malapposed struts 2.2%, LSE 1.76 (95% CI 0.05-3.58), and protruding struts 2.9%, LSE 2.8 (95% CI 1.35-4.65). The proportion of uncovered malapposed struts was significantly higher compared to uncovered embedded struts (55.7% vs. 6.8%, p < 0.01). In total, 5 (25%) PES were fully covered by neointima. No intracoronary thrombus or clinical events were detected.

Conclusions

Six months after implantation of a specific PES in patients with ACS, most of the stents were only partially covered with neointima, especially at sites of strut malapposition or protrusion. These findings emphasize the need for optimal stent apposition during implantation and for prolonged dual antiplatelet therapy.  相似文献   

4.
  • The current meta‐analysis evaluates the relationship of late incomplete stent apposition (LISA) observed either by IVUS or OCT 6–18 months after PCI and long‐term outcomes, particularly in regard to stent thrombosis (ST) and has demonstrated a small but significant increase in ST with LISA.
  • The results of the current study do not apply to acute stent malapposition whose relevance to adverse outcomes is uncertain based on current evidence and a malapposition classification based on presence, length, and severity of malapposed struts.
  • A classification of stent malapposition based on cause of malapposition is proposed as a method to determine prognostic importance of acute incomplete stent apposition.
  相似文献   

5.
Compared with the bare metal stent (BMS), suppression of neointimal growth in the sirolimus-eluting stent (SES) reduced restenosis at the cost of more exposed struts that could impose the risk of stent thrombosis. The present study was conducted to analyze neointimal coverage patterns of stents at a strut-level after implantation of BMS or SES with the use of optical coherence tomography (OCT). We enrolled 35 patients and analyzed neointimal coverage of every strut from 41 stents (BMS: n = 8, SES: n = 33) by using OCT at follow-up of the stent implantation. All of the 371 struts from eight BMSs were covered with ≥100 μm of neointima, while 19.8 and 3.5 % of 3,478 struts from 33 SESs were uncovered (neointimal thickness of <10 μm) and malapposed, respectively. The histogram of neointimal thickness showed basically normal distribution in BMS but skewed in SES. No regional difference in neointimal thickness was observed in BMS (proximal, 535.7 ± 25.2 μm; body, 532.4 ± 17.0 μm; distal, 485.8 ± 27.0 μm). In SES, however, the body segment showed thinner neointima [median 40 μm (interquartile range (IQR) 10–90 μm)] than proximal [60 μm (IQR 10–140 μm), p < 0.001] or distal [50 μm (IQR 10–110 μm), p < 0.001] segment, while uncovered and malapposed struts were more frequent in the proximal and body segments. In conclusion, SES, compared with BMS, showed more suppressed neointimal growth with regional variation: neointimal thickness was the least in the body part while the ratio of exposed and malapposed struts was minimal in the distal segment. OCT was useful for a strut-level analysis of neointimal coverage over the whole stent.  相似文献   

6.
PurposeZilver PTX nitinol self-expanding drug-eluting stent with paclitaxel coating is effective for treatment of superficial femoral artery (SFA) disease. However, as with any stent, it induces a measure of vascular inflammatory response. The current clinical trial (NCT02734836) aimed to assess vascular patency, remodeling, and inflammatory markers with intravascular optical coherence tomography (OCT) in patients with SFA disease treated with Zilver PTX stents.MethodsSerial OCT examinations were performed in 13 patients at baseline and 12-month follow-up. Variables evaluated included neointimal area, luminal narrowing, thrombus area, stent expansion as well as measures of inflammation including, peri-strut low-intensity area (PLIA), macrophage arc, neovascularization, stent strut apposition and coverage.ResultsPercentage of malapposed struts decreased from 10.3 ± 7.9% post-intervention to 1.1 ± 2.2% at 12-month follow-up, but one patient showed late-acquired stent malapposition (LASM). The percent of uncovered struts at follow-up was 3.0 ± 4.5%. Average expansion of stent cross-sectional area from baseline to follow-up was 35 ± 19%. The average neointimal area was 7.8 ± 3.8 mm2. Maximal luminal narrowing was 61.1 ± 25.0%, and average luminal narrowing was 35.4 ± 18.2%. Average peri-strut low-intensity area (PLIA) per strut was 0.017 ± 0.018 mm2. Average number of neovessels per mm of stent was 0.138 ± 0.181. Average macrophage angle per frame at follow-up was 7 ± 11°. Average thrombus area at follow-up was 0.0093 ± 0.0184 mm2.ConclusionAt 12-month follow-up, OCT analysis of Zilver PTX stent shows outward remodeling and minimal neointimal growth, but evidence of inflammation including PLIA, neovessels, thrombus and macrophages.SummaryThirteen patients with PAD had paclitaxel-coated stents implanted in their SFAs and were then imaged with OCT at baseline and 12-month follow-up. OCT proxy metrics of inflammation were quantified.  相似文献   

7.
ObjectivesTo compare the early vascular healing of ruptured plaques (RP) and non-ruptured plaques (NRP) one month after primary percutaneous coronary intervention (PCI) in patients with ST-segment elevation myocardial infarction (STEMI), using optical coherence tomography (OCT).BackgroundVascular healing and strut coverage are important factors in reducing the risk of stent thrombosis after PCI. Influence of underlying lesion characteristics and differences in healing response between RP and NRP are unknown.MethodsTwenty-six STEMI-patients underwent PCI and implantation of a polymer-free drug-coated Biofreedom stent (BF-BES). OCT was performed pre-PCI, post-PCI and at 1-month follow-up. The patients were divided into two groups: RP = 15 and NRP = 11. OCT analyses of culprit lesion, post stent implantation at baseline and follow-up were performed to determine the difference in vascular healing based on presence of uncovered and/or malapposed stent struts and intraluminal filling defects.ResultsThe stent coverage did not differ significantly between the two groups at 1-month follow-up with percentage of uncovered struts: RP 26.5% [IQR 15.0–49.0] and NRP 28.1% [IQR 15.5–38.8] for NRP (p = 0.78). At 1-month, RP showed an increased percentage of late acquired malapposed struts (1.4% [IQR 0.8–2.4] vs. 0.0% [IQR 0.0–1.4], p = 0.03) and a larger total malapposition area (1.3 mm2 [IQR 0.4–2.5] vs. 0.0 mm2 [IQR 0.0–0.9], p = 0.01), compared to NRP.ConclusionThree out of four struts were covered within one month after stenting. The vascular healing was comparable in RP and NRP on stent coverage. However, RP had more and larger late acquired malapposition areas.  相似文献   

8.
ObjectivesWe sought to investigate stent healing and neointimal hyperplasia with ihtDEStiny drug-eluting stent (DES) by optical coherence tomography (OCT) examination conducted 9 months after implantation.BackgroundThe currently used DES present certain features that have been linked separately to their better performance in terms of efficacy and safety.MethodsFirst-in-man, prospective and multicenter study including patients treated with ihtDEStiny stent undergoing OCT examination at 9 months follow up. The ihtDEStiny stent is a sirolimus eluting stent with an oval shape ultrathin struts (68 μm) and an abluminal coating of a fluoropolymer containing the antiplatelet agent triflusal. Primary endpoint was the percentage of obstruction of the in-stent volume by the neointima.ResultsIn 58 patients (63 lesions) in-stent late lumen loss was 0.11 ± 0.23 mm (95% CI 0.05–0.16) with only in 6% of stents being > 0.5 mm and in-segment binary stenosis was 1.6%. In OCT mean neointima volume obstruction was 10.5 ± 6.9% with a mean neointima thickness of 110.9 ± 89.8 μm. The proportion of uncovered struts was 2.5%, malapposed struts 1.1% and malapposed/uncovered struts 0.7% and no subclinical thrombi detected. Mean incomplete stent apposition area was 0.1 ± 0.1 mm2. At 12 months target lesion revascularization rate was 3% and no stent thrombosis was reported.ConclusionsIn this study the ihtDEStiny stent has shown a very low degree of neointimal proliferation associated with a low rate of uncovered/malapposed struts and total absence of subclinical thrombi at 9 months follow up.  相似文献   

9.

Background

Pathology studies have shown delayed arterial healing in culprit lesions of patients with acute coronary syndrome (ACS) compared with stable coronary artery disease (CAD) after placement of drug-eluting stents (DES). It is unknown whether similar differences exist in-vivo during long-term follow-up. Using optical coherence tomography (OCT), we assessed differences in arterial healing between patients with ACS and stable CAD five years after DES implantation.

Methods and results

A total of 88 patients comprised of 53 ACS lesions with 7864 struts and 35 stable lesions with 5298 struts were suitable for final OCT analysis five years after DES implantation. The analytical approach was based on a hierarchical Bayesian random-effects model. OCT endpoints were strut coverage, malapposition, protrusion, evaginations and cluster formation. Uncovered (1.7% vs. 0.7%, adjusted p = 0.041) or protruding struts (0.50% vs. 0.13%, adjusted p = 0.038) were more frequent among ACS compared with stable CAD lesions. A similar trend was observed for malapposed struts (1.33% vs. 0.45%, adj. p = 0.072). Clusters of uncovered or malapposed/protruding struts were present in 34.0% of ACS and 14.1% of stable patients (adj. p = 0.041). Coronary evaginations were more frequent in patients with ST-elevation myocardial infarction compared with stable CAD patients (0.16 vs. 0.13 per cross section, p = 0.027).

Conclusion

Uncovered, malapposed, and protruding stent struts as well as clusters of delayed healing may be more frequent in culprit lesions of ACS compared with stable CAD patients late after DES implantation. Our observational findings suggest a differential healing response attributable to lesion characteristics of patients with ACS compared with stable CAD in-vivo.  相似文献   

10.
A 76-year-old man presented with an anterior myocardial infarction. Coronary angiography showed 99% stenosis in the left anterior descending artery and total occlusion in the left circumflex artery (LCX). After successful percutaneus coronary intervention (PCI) for segment 7, a staged PCI to the LCX with a distal protection system was attempted, but the wire entered the subintima, creating a large dissection and intramural hematoma. Three sirolimus-eluting stents (SES) were implanted to cover the entire hematoma, but 2 weeks later intravascular ultrasound revealed stent malapposition, with healing of the residual hematoma, and vessel enlargement. Optical coherence tomography (OCT) showed the malapposition more clearly. Balloon dilatation successfully achieved apposition of the SES to the vessel wall, but 6 months later it revealed recurrence of malapposition, with the struts covered by thrombus-like tissue. This case suggests that SES implantation treatment of a long intramural hematoma can potentially cause late malapposition because of persistent vessel enlargement related to arterial wall injury and inhibition of neointimal hyperplasia by the SES. OCT is useful in showing the precise condition of the stent struts.  相似文献   

11.
A 90-year-old man was admitted to our hospital with acute ST-segment elevation myocardial infarction. He had a history of post-infarction angina pectoris 79 months ago and had a bare-metal stent (BMS) implanted in the proximal left anterior descending artery at our hospital. Emergent coronary angiography demonstrated thrombotic occlusion in the previously stented segment. After catheter thrombectomy, antegrade flow was restored, but 90% stenosis with haziness persisted in the proximal and distal portions of the previously stented segment. Intravascular ultrasound imaging showed interstrut cavities or stent malapposition at the proximal and distal sites of stented segment. In close proximity to the sites, residual thrombi were also observed. Optical coherence tomography (OCT) demonstrated neither lipid-laden neointimal tissue nor rupture but clearly demonstrated residual thrombus adjacent to the malapposed region in addition to the stent malapposition. PCI with balloon was successfully performed and stent apposition was confirmed by OCT. Stent malapposition is an unusual mechanism of very late stent thrombosis after BMS implantation. OCT can clearly reveal the etiology of stent thrombosis.  相似文献   

12.
The efficacy of DEB in modifying the high restenosis risk associated with BMS implantation is doubtful. Optical coherence tomography (OCT) may allow precise assessment of neointimal formation after stent implantation. We performed a single-center, prospective, 1:2 randomized trial comparing BMS implantation alone (BMS group) vs. additional DEB (DEB group). DEB patients were further randomized 1:1 to DEB before stenting (pre-DEB group), or after stenting (post-DEB group). Primary endpoint was OCT-assessed neointimal hyperplasia (expressed both as mean in-stent neointimal area and as percentage obstruction of the mean stent area) at 6 months. Secondary endpoints were the percentage of uncovered and malapposed stent struts. Thirty patients were enrolled and randomized to BMS (n = 10), pre-DEB (n = 10), post-DEB (n = 10). At 6-month OCT follow-up, DEB significantly reduced neointimal area compared with BMS: mean neointimal area 2.01 ± 0.89 vs. 3.03 ± 1.07 mm2 (p = 0.02), percentage area obstruction 24.56 ± 12.50 vs. 37.51 ± 12.26 % (p = 0.02). The percentage of uncovered and malapposed stent struts did not differ significantly between BMS and DEB. In the comparison between pre-DEB and post-DEB, no significant difference was observed for both primary and secondary endpoints. In de novo coronary lesions treated with BMS, DEB use could be associated with a mild reduction in neointimal hyperplasia at 6 months; this effect could be unrelated to the timing of DEB dilation (pre- or post-stenting).Clinical Trial Registration Information: http://www.clinicaltrials.gov. Identifier: NCT01057563.  相似文献   

13.
Objective:To evaluate neointimal coverage after Drug Eluting Stent implantation without no restenosis during angiographic follow up by using optical coherence tomography(OCT).Methods:18 case enrolled into this project who received angiography follow up and OCT checkout.Results:1.Totally,4709 struts were analyzed and 88.6% were completely covered with neointimal,and 0.7% were partly covered and 8.1% were uncovered.The rate of late malapposition of struts was 2.6%.The average neointimal hyperplasia thickness...  相似文献   

14.

Background

No randomized studies have been conducted to investigate serial changes in optical coherence tomography (OCT) analyses following implantation of biolimus-A9-eluting stents (BES) and sirolimus-eluting stents (SES).

Methods

A total of 60 patients fulfilling the study criteria were randomly assigned into BES (n = 30) and SES (n = 30) implantation groups. Serial OCT evaluation at post-procedure, 3- and 12-month follow-up was performed in 46 patients [BES (n = 22) and SES (n = 24)]. OCT analyses were compared according to the type of stents and the follow-up time intervals. The percentage of uncovered struts was defined as the ratio of uncovered struts to total struts in all cross-sections. The primary endpoint was the percentage change (Δ) of uncovered struts in the 3- and 12-month follow-up samples.

Results

The percentage of uncovered struts at the 3-month time period was not significantly different in the BES and SES groups; the median value (interquartile range) was 14.7% (0.0–23.4) versus 8.6% (0.7–21.5) (p = 0.98), respectively. However, OCT at the 12-month follow-up showed a significantly lower percentage of uncovered struts [2.6% (0.8–5.6) versus 6.2% (1.7–14.7), (p = 0.028), respectively] without significant difference of neointimal thickness. BES showed a greater reduction of percentage Δ of uncovered struts from 3–12 months than that of SES [− 17.2 ± 14.5% versus − 7.7 ± 16.3%, respectively (p = 0.043)].

Conclusions

Both drug-eluting stents showed a high percentage of incomplete strut coverage at 3 months. However, BES showed a significantly lower percentage of uncovered struts at 12 months compared to that of SES. This was achieved by superior strut coverage from 3 to 12 months.  相似文献   

15.
目的:通过支架释放同时推注造影剂(Simultaneous injection contrast,SIC),判断支架贴壁情况与光学相干断层成像(optical coherence tomography,OCT),测量支架小梁与血管内膜之间距离,对比评价SIC方法,判断术后即刻支架贴壁情况的实用性。方法:入选21例原位病变的冠心病患者,行支架植入术的同时通过释放支架,同时推注造影剂(SIC)方法判断支架大体的贴壁情况,同时记录支架的型号释放压力等,之后用光学相干断层成像(OCT)精确判断支架的贴壁情况,并对OCT图像每隔1 mm的横截面的支架小梁的贴壁情况进行记录和分析,通过两者的结果对比,评价SIC方法在支架贴壁情况中的实用性。结果:21例患者中共植入支架34枚,其中2个支架节段用SIC及OCT判断均存在贴壁不良,11个支架节段SIC判断贴壁良好,而经OCT检查发现存在>1%的支架小梁贴壁不良。SIC和OCT检查均为贴壁良好的支架节段有21个。结论:SIC方法是在临床实践中一种简便实用的判断支架贴壁情况的方法,虽然其准确性难以与OCT相媲美,但作为一种简便经济的方法,值得在临床推广使用。  相似文献   

16.
ObjectivesThis study sought to evaluate the impact of poststent optical coherence tomography (OCT) findings, including severe malapposition, on long-term clinical outcomes.BackgroundSuboptimal OCT findings following percutaneous coronary intervention (PCI) are highly prevalent; however, their clinical implications remain controversial.MethodsOf the patients registered in the Yonsei OCT registry, a total of 1,290 patients with 1,348 lesions, who underwent OCT immediately poststenting, were consecutively enrolled for this study. All patients underwent implantation of drug-eluting stents. Poststent OCT findings were assessed to identify predictors of device-oriented clinical endpoints (DoCE), including cardiac death, target vessel-related myocardial infarction (MI) or stent thrombosis, and target lesion revascularization (TLR). Significant malapposition criteria associated with major safety events (MSE) were also investigated, such as cardiac death, target vessel-related MI, or stent thrombosis.ResultsThe median follow-up period was 43.0 months (interquartile range [IQR] 21.4 to 56.0 months). The incidence rates of stent edge dissection, tissue prolapse, thrombus, and malapposition after intervention were not associated with occurrence of DoCE. However, patients with significant malapposition (total malapposition volume [TMV] ≥7.0 mm3] exhibited more frequent MSE. A smaller minimal stent area (MSA) was identified as an independent predictor for DoCE (hazard ratio [HR]: 1.20 [95% confidence interval [CI]: 1.00 to 1.43]; p = 0.045). Malapposition with TMV ≥7.0 mm3 was found to be an independent predictor of MSE (HR: 6.12 [95% CI: 1.88 to 19.95]; p = 0.003). Follow-up OCT at 3, 6, or 9 months after PCI showed that poststent TMV ≥7.0 mm3 was related to a greater occurrence of late malapposition and uncovered struts.ConclusionsAlthough most suboptimal OCT findings were not associated with clinical outcomes, a smaller MSA was associated with DoCE, driven mainly by TLR, and significant malapposition with TMV ≥7.0 mm3 was associated with more MSE after PCI. (Yonsei OCT [Optical Coherence Tomography] Registry for Evaluation of Efficacy and Safety of Coronary Stenting; Yonsei OCT registry; NCT02099162)  相似文献   

17.

Background

We used optical coherence tomography (OCT) and intravascular ultrasound (IVUS) to assess the struts of implanted stents in patients with acute coronary syndrome (ACS).

Methods

A totle of 10,756 stent struts were analyzed with OCT in 42 patients of ACS. Of them, both of IVUS and OCT imaging were performed in 33 patients. Appearance of stent struts was classified as well apposed, buried, malapposed, and nondetectable, and the number of stent struts were counted by OCT and IVUS was compared.

Results

Most of stent struts were well apposed (78.1%, 8,407/10,756). However, malapposed struts were 5.6% (607/10,756), and 14.1% (1,514/10,756) of stent struts were buried by thrombus. The nondetectable struts were 2.11% (228/10,756) in ACS. 94.7% (216/228) of nondetectable stent struts were associated with red thrombus, and plaque prolapse was in 5.3% (12/228). The number of stent struts counted by OCT were larger than that of IVUS. The mean number of stent struts at the proximal and distal stent edges were 24 ± 6.57 in OCT, the stent struts IVUS counted were 20 ± 4.18 (P < 0.0001). Although the frequency of malapposed struts were similar 4.6% (376/8,248) in OCT versus 4.8% (369/7,674) in IVUS (P = 0.788). Stent struts were often buried by thrombus in ACS 15.2% (1,252/8,248) in OCT versus 9.7% (747/7,674) in IVUS; P = 0.006. The nondetectable struts were fewer in IVUS than OCT 0.2% (16/7,674) in IVUS versus 2.2% (187/8,248) in OCT; P < 0.0001.

Conclusion

Stent struts are frequently buried and nondetectable due to thrombi burden in ACS patients. Adequate thrombus removal and proper selection of the imaging device is warranted in ACS. (J Interven Cardiol 2016;29:99–107)
  相似文献   

18.
Objective:Confirming complete neointimal coverage after implantation of drug-eluting stent(DES)is clinically important because incomplete stent coverage is maybe responsible for late thrombosis and sudden cardiac death.Optical coherence tomography(OCT)is a high-resolution(≈10 μm)imaging technique capable of detecting a thin layer of neointimal hyperplasia(NIH)inside DES.Helios stent system(KinheIy Bio-tech Co(Shenzhen).Ltd)is a new generation of sirolimus eluting stents.Methods:Motorized optical coherence t...  相似文献   

19.

Objective

We aimed to assess early neointimal healing by optical coherence tomography (OCT) 3 months after implantation of the ultrathin Orsiro® sirolimus‐eluting stent with biodegradable polymer.

Background

New generations of drug‐eluting stents with biodegradable polymer have been developed to avoid the continued vascular irritation of durable polymers.

Methods

In this prospective, open‐label study, 34 patients received an Orsiro® sirolimus‐eluting stent with biodegradable polymer. In a subgroup of patients (n = 15), the intervention was performed under OCT guidance. All patients underwent OCT‐examination at three months. The primary endpoint was 3‐month neointimal healing (NIH) score, calculated by weighing the presence of filling defects, malapposed and uncovered struts. Secondary endpoint was maturity of tissue coverage at 3 months.

Results

At 3 months, NIH score was 13.7 (5.4‐22), covered struts per lesion were 90% (84‐97%), malapposed struts were 2.7% (0.8‐5.4%) and rate of mature tissue coverage was 47% (42‐53%). No target lesion failure occurred up to 12 months. Patients with OCT‐guided stent implantation demonstrated a trend toward earlier stent healing as demonstrated by superior NIH scores (angio guided: 17.6% [8.8‐26.4]; OCT‐guided: 9.8% [4.0‐15.5]; mean difference ?8, [95%CI: ?18.7‐2.9], P = 0.123). This group had significantly more covered struts per lesion (angio‐guided: 86% [82‐90]; 95% [92‐99]; mean difference 9% [95%CI: 3‐15], P = 0.001).

Conclusion

The Orsiro® sirolimus‐eluting stent with biodegradable polymer shows early vascular healing with a high rate of strut coverage at 3‐month follow‐up. OCT guided stent implantation had a positive impact on early vascular healing.
  相似文献   

20.
光学相干断层成像在冠心病介入治疗中的应用价值   总被引:8,自引:0,他引:8  
目的应用光学相干断层成像(OCT)技术评价冠状动脉内粥样硬化斑块、血管对置入支架后即刻和中远期的反应。方法20例冠心病患者,有22支血管在完成冠状动脉造影或介入治疗后进行OCT成像。同时获取23个支架OCT成像,在23个支架中有15个为支架术后4~35个月随访,其中7个为雷帕霉素药物洗脱支架,8个为金属裸支架,另外8个为支架置放后即刻成像。结果入选的20例患者均成功进行OCT检查,并获取22支血管和23个支架满意的图像。通过OCT成像清晰地显示8处纤维斑块、3处钙化斑块、9处富含脂质斑块、2处血栓形成、斑块破裂3处及血管壁上夹层、粥样硬化斑块微小裂口和夹层等。7个置入雷帕霉素药物洗脱支架后OCT随访,均未发现有明显再狭窄,支架表面有少量内膜覆盖,部分支架表面没有内膜覆盖,其中1个支架血管出现瘤样扩张、支架与血管壁分离、支架表面没有内膜覆盖,有1个支架没有充分扩张。8个金属裸支架后用OCT随访发现,所有置入金属裸支架后支架表面内膜增殖明显,其中有3个支架因为内膜过度增殖而出现再狭窄,并再次接受介入治疗。8个支架术后即刻OCT检查显示,与血管贴壁均良好、支架扩张充分有3个支架,4个支架充分扩张,但可见到斑块裂片通过支架网眼突入管腔,1个支架支撑杆分布不均,可见支架与血管壁分离,在8个支架中有2个为支架内套叠支架。结论OCT成像技术可清晰显示各种冠状动脉粥样斑块情况,并可用于评价冠状动脉介入治疗的效果。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号