首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ObjectivesMinisternotomy and right anterior minithoracotomy are the 2 main techniques applied for minimally invasive aortic valve replacement. The goal of this study is to compare early and long-term outcomes of both techniques.MethodsThe data of 2419 patients undergoing isolated minimally invasive aortic valve replacement between 1999 and 2019 were prospectively collected. Retrospectively, patients were divided into the ministernotomy group (n = 1352) and the minithoracotomy group (n = 1067).ResultsAfter propensity score matching, 986 patients remained in each group. Operation time and rate of conversion to full sternotomy were significantly higher in the minithoracotomy group than in the ministernotomy group (184.6 ± 45.2 vs 241.3 ± 68.6, relative risk, 2.54, P = .005 and .09 vs .23, relative risk, 1.45, P = .013, respectively). The 30-day mortality, excluding cardiac death, was lower in the ministernotomy group than in the minithoracotomy group (0.012 vs 0.028, relative risk, 1.41, P = .011, respectively); the intensive care unit length of stay (12.4 vs 16.5, relative risk, 1.62, P = .037, respectively) and hospital length of stay (5.4 vs 8.7, relative risk, 1.74 P = .028, respectively) were significantly longer in the minithoracotomy group. The minithoracotomy surgical approach was the strongest independent predictor of early mortality (odds ratio, 4.24 [1.67-7.35], P = .002). The actuarial survival by Kaplan–Meier analysis at 1, 3, 5, 10, and 20 years was significantly better in the ministernotomy group than in the minithoracotomy group (P = .0001). Actuarial freedom from reoperation at 5 years was 97.3% ± 4.4% in the ministernotomy group versus 95.8% ± 5.2% in the minithoracotomy group (P = .087).ConclusionsMinimally invasive aortic valve replacement using ministernotomy is associated with reduced operative time, intensive care unit stay, hospital length of stay, and postoperative morbidities and incisional pain, and improves early and long-term mortality.  相似文献   

2.
BackgroundValve-sparing root replacement (VSRR) has excellent outcomes when performed in experienced centers in well-selected patients. It is suggested that reimplantation of the aortic valve may have better durability than remodeling in patients with Marfan syndrome (MFS), although long-term comparative data are limited.MethodsBetween 1988 and 2018, 194 patients with MFS underwent VSRR at our institution. From these, we derived a propensity-matched cohort of 68 patients (44 who underwent reimplantation and 24 who had remodeling). Early outcomes included death and perioperative complications. Late outcomes were survival, probability of aortic insufficiency, and reintervention up to 20 years of follow-up. Median follow-up was 17.8 years (interquartile range, 12.0-20.6 years) for the entire matched cohort.ResultsBaseline variables were similar between reimplantation and remodeling patients after matching: age (39 ± 12 vs 40 ± 13 years, P = .75) and male sex (28 [64%] vs 15 [63%], P = 1.0). Similar 20-year survival was observed after reimplantation compared with remodeling (82% vs 72%, P = .20), whereas the probability of developing greater than mild aortic insufficiency at 20 years was increased after remodeling (5.8% vs 13%, P = .013). More patients underwent reoperation on the aortic valve after a remodeling procedure than after reimplantation of the aortic valve (18% vs 0%, P = .018).ConclusionsVSRR provides excellent long-term survival and freedom from valve-related complications outcomes in patients with MFS. Reimplantation of the aortic valve was associated with a lower risk of aortic valve reoperation and aortic insufficiency than the remodeling procedure after 2 decades of follow-up.  相似文献   

3.
ObjectiveValve-sparing root replacement using reimplantation techniques is increasingly applied to bicuspid aortopathy. Long-term durability of cusp repair is unclear. We analyze midterm results using a conservative approach to cusp repair.MethodsFrom 2006 to 2018, 327 patients underwent valve-sparing reimplantation, 66 with bicuspid valves. Leaflets were analyzed after reimplantation. A majority (51/66) required no cusp repair. Fifteen patients had cusp repair limited to closure of unfused raphe or central plication. Patients were followed by echocardiography.ResultsMean age of patients was 44.7 ± 12.3 years. The cusp repair group had a higher incidence of preoperative moderate (10% vs 40%) or severe (4% vs 33.3%) aortic insufficiency (P < .001). There was no operative mortality or major complication. Mean follow-up was 51.6 ± 40.8 months. On postoperative echocardiography, incidence of none, trace, or mild aortic insufficiency was 41.3% (19/46), 43.5% (20/46), and 15.2% (7/46) in the no cusp repair group and 40% (6/15), 40% (6/15), and 20% (3/15) in the cusp repair group, respectively (P = .907). Few patients progressed in degree of aortic insufficiency. No patients required reoperation. At 5 years, freedom from any aortic insufficiency was 46.9% versus 15.8% (P = .013), and freedom from greater than trace aortic insufficiency was 59.1% versus 36.9% (P = .002) due to the higher rate of postoperative trace and mild aortic insufficiency with cusp repair. There was no difference in freedom from greater than mild aortic insufficiency (92.1% vs 100%; P = .33).ConclusionsValve-sparing root replacement is reliably performed with bicuspid aortic valves whether or not cusp reconstruction is necessary. Few patients progress to greater than mild aortic insufficiency. Need for reoperation is rare in midterm follow-up.  相似文献   

4.
BackgroundChild abuse is a significant cause of injury and death among children, but accurate identification is often challenging. This study aims to assess whether racial disparities exist in the identification of child abuse.MethodsThe 2010–2014 and 2016–2017 National Trauma Data Bank was queried for trauma patients ages 1–17. Using ICD-9CM and ICD-10CM codes, children with injuries consistent with child abuse were identified and analyzed by race.ResultsBetween 2010–2014 and 2016–2017, 798,353 patients were included in NTDB. Suspected child abuse victims (SCA) accounted for 7903 (1%) patients. Of these, 51% were White, 33% Black, 1% Asian, 0.3% Native Hawaiian/Other Pacific Islander, 2% American Indian, and 12% other race. Black patients were disproportionately overrepresented, composing 12% of the US population, but 33% of SCA patients (p < 0.001). Although White SCA patients were more severely injured (ISS 16–24: 20% vs 16%, p < 0.01) and had higher in-hospital mortality (9% vs. 6%, p = 0.01), Black SCA patients were hospitalized longer (7.2 ± 31.4 vs. 6.2 ± 9.9 days, p < 0.01) despite controlling for ISS (1–15: 4. 5.7 ± 35.7 vs. 4.2 ± 6.2 days, p < 0.01). In multivariate regression, Black children continued to have longer lengths of stay despite controlling for ISS and insurance type.ConclusionsUtilizing a nationally representative dataset, Black children were disproportionately identified as potential victims of abuse. They were also subjected to longer hospitalizations, despite milder injuries. Further studies are needed to better understand the etiology of the observed trends and whether they reflect potential underlying unconscious or conscious biases of mandated reporters.Type of studyTreatment study.Level of evidenceIII.  相似文献   

5.
BackgroundModerate hypothermic circulatory arrest (MHCA) with antegrade cerebral perfusion (ACP) is safe and efficient in total arch replacement (TAR) and frozen elephant trunk (FET) for acute type A aortic dissection (ATAAD). Complications related to hypothermia and ischemia are inevitable, however. The aortic balloon occlusion (ABO) technique is performed to elevate the lowest nasopharyngeal temperature to 28°C and shorten the circulatory arrest time. In this study, we aimed to evaluate the efficacy of this new technique.MethodsWe reviewed the clinical data of patients with ATAAD who underwent TAR and FET, including 79 who underwent ABO and 109 who underwent MHCA/ACP.ResultsCirculatory arrest time was significantly lower in the ABO group compared with the MHCA/ACP group (mean, 4.8 ± 1.2 minutes vs 18.4 ± 3.1 minutes; P < .001). The composite endpoint was comparable in the 2 groups (11.4% for ABO vs 13.8% for MHCA/ACP; P = .631). Fewer patients in the ABO group developed high-grade acute kidney injury (AKI) according to a modified RIFLE criterion (22.8% vs 36.7%; P = .041), and the rate of hepatic dysfunction was lower in the ABO group (11.4% vs 28.4%; P = .005). Multivariable logistic analysis showed that the ABO technique is protective against duration of ventilation >24 hours (odds ratio [OR], 0.455; 95% confidence interval [CI], 0.234-0.887; P = .021), hepatic dysfunction (OR, 0.218; 95% CI, 0.084-0.561; P = .002), and grade II-III AKI (OR, 0.432; 95% CI, 0.204-0.915; P = .028).ConclusionsThe ABO technique significantly shortens the circulatory arrest time in TAR and FET. Available clinical data suggest that it has a certain protective effect on the liver and kidney. Future large-sample studies are warranted to thoroughly evaluate this new technique.  相似文献   

6.
ObjectivesTo assess the effect of DuraGraft (Somahlution Inc, Jupiter, Fla), an intraoperative graft treatment, on saphenous vein grafts in patients undergoing isolated coronary artery bypass grafting.MethodsWithin patients, 2 saphenous vein grafts were randomized to DuraGraft or heparinized saline. Multidetector computed tomography angiography at 1, 3, and 12 months assessed change in wall thickness (primary end point at 3 months), lumen diameter, and maximum narrowing for the whole graft and the proximal 5-cm segment. Safety end points included graft occlusion, death, myocardial infarction, and repeat revascularization.ResultsAt 3 months, no significant changes were observed between DuraGraft- and saline-treated grafts (125 each) for wall thickness, lumen diameter, and maximum narrowing. At 12 months, DuraGraft-treated grafts demonstrated smaller mean wall thickness, overall (0.12 ± 0.06 vs 0.20 ± 0.31 mm; P = .02) and in the proximal segment (0.11 ± 0.03 vs 0.21 ± 0.33 mm; P = .01). Changes in wall thickness were greater in the proximal segment of saline-treated grafts (0.09 ± 0.29 vs 0.00 ± 0.03 mm; P = .04). Increase in maximum graft narrowing was larger in the proximal segment in the saline-treated grafts (4.7% ± 12.7% vs 0.2% ± 3.8%; P = .01). Nine DuraGraft and 11 saline grafts had occluded or thrombosed. One myocardial infarction was associated with a saline graft occlusion. No deaths or revascularizations were observed.ConclusionsDuraGraft demonstrated a favorable effect on wall thickness at 12 months, particularly in the proximal segment. Longer-term follow-up in larger studies is needed to evaluate the effect on clinical outcomes.  相似文献   

7.
ObjectiveThe study objective was to investigate the long-term survival of patients undergoing xenograft versus homograft full root aortic valve replacement.MethodsA total of 166 patients requiring aortic valve surgery were randomized to undergo the Freestyle (Medtronic Inc, Minneapolis, Minn) bioprosthesis (N = 90) or a homograft (N = 76) full root aortic valve replacement between 1997 and 2005 in a single institution. Six patients randomly assigned to the homograft crossed over to the Freestyle bioprosthesis because of the unavailability of suitably sized homografts. All surgeons were required to adhere to the standard surgical technique for homograft root implantation previously described. Follow-up was 98.5% complete.ResultsThe mean age of the study population was 65 ± 8 years. Coronary artery bypass grafting was associated with root aortic valve replacement in 76 of 166 patients (46%, P = not significant between groups), and overall hospital mortality was 4.8% (8/166, P = not significant between groups). Median follow-up was 13.8 years (range, 0-21.8 years; 2033 patient-years). The Kaplan–Meier survival analysis showed that there was no significant difference in overall survival between the 2 arms at 5, 10, and 15 years. Twenty-year survival was 28.3% ± 5% for the Freestyle group versus 25.1% ± 5.7% for the homograft group (P = .90), which was comparable to the age- and sex-matched UK general population. The freedom from aortic valve reoperation at 20 years was comparable for the Freestyle group versus the homograft group (67.9% ± 8.8% vs 67.2% ± 10.3%, respectively; P = .74).ConclusionsThis is the first study to investigate the long-term survival of xenograft versus homograft full root aortic valve replacement from a prospective randomized trial. The observed 20-year overall survival and freedom from aortic valve reoperation serve as a benchmark for future studies on interventions for aortic valve disease in the elderly.  相似文献   

8.
PurposeThe purpose of this study was to retrospectively compare two puncture routes (transpleural vs. transpulmonary) for computed tomography (CT) fluoroscopy-guided cutting needle biopsy of lung nodules with pleural contact.Patients and methodsA total of 102 patients (72 men; mean age, 71.1 ± 9.5 [SD] years) were included and 102 biopsies of 102 lung nodules (mean size, 16.7 ± 5.9 [SD] mm; range, 6.0–29.4 mm; mean length of pleural contact, 10.1 ± 4.2 [SD] mm; range, 2.8–19.6 mm) were analyzed. All procedures were classified as biopsies via the direct transpleural route or the transpulmonary route. The patient-, lesion-, and biopsy-related variables, diagnostic yields, and incidence of complications were compared between the two routes.ResultsBiopsy was performed via the direct transpleural route (n = 59; 57.8%) and transpulmonary route (n = 43; 42.2%). In the transpulmonary route group, the mean distance of the intrapulmonary pathway was 17.7 ± 9.4 [SD] mm (range: 4.1–47.6 mm; P < 0.001) and the introducer needle trajectory angle of < 45° was significantly observed (8.5% [5/59] vs. 60.5% [26/43]; P < 0.001). There was no significant difference in diagnostic accuracy between the direct transpleural and transpulmonary routes (93.2% [55/59] vs. 90.7% [39/43]; P = 0.718). The frequencies of all complications (64.4% [38/59] vs. 97.7% [42/43]; P < 0.001), pneumothorax (33.9% [20/59] vs. 65.1% [28/43]; P = 0.003), pneumothorax with chest tube placement (3.4% [2/59] vs. 18.6% [8/43]; P = 0.016), and pulmonary hemorrhage (47.5% [28/59] vs. 76.7% [33/43]; P = 0.004) were significantly lower in the direct transpleural group.ConclusionDirect transpleural route is recommended for CT fluoroscopy-guided biopsy of lung nodules with pleural contact because it is safer and yields similar diagnostic accuracy than transpulmonary route.  相似文献   

9.
ObjectivesLobar lung transplantation (LLTx) from deceased donors is a potential solution for donor–recipient size mismatch for small sized recipients. We reviewed our institutional experience to compare outcomes after LLTx to standard lung transplantation (LTx).MethodsWe retrospectively reviewed transplants in our institution from January 2000 to December 2017. LLTx early- and long-term outcomes were compared with LTx. Additional analysis of outcomes was performed after dividing the cohort into 2 eras (era 1, 2000-2012; era 2, 2013-2017).ResultsAmong the entire cohort (1665), 75 were LLTx (4.5%). Compared with LTx, LLTx were more frequently bridged to transplant with extracorporeal life support or mechanical ventilation and were transplanted in a rapidly deteriorating status (respectively, 20% vs 4.4%, P = .001; 22.7% vs 7.9, P < .001; and 41.3% vs 26.5%, P = .013). LLTx had longer intensive care unit and hospital lengths of stay (respectively, median 17 vs 4 days, and 45 vs 23, both P < .001), and greater 30-day mortality (13.3% vs 4.3%, P = .001) and 90-day mortality (17.3% vs 7.2%, P = .003). In era 2, despite a significantly greater 30-day mortality (10.8% vs 2.8%, P = .026), there was no significant difference in 90-day mortality between LLTx and LTx (13.5% vs 5.1%, P = .070). Overall survival at 1, 3, and 5 years was not significantly different between LLTx and LTx (73.2% vs 84.4%, 56.9% vs 68.4% and 50.4% vs 55.8, P = .088).ConclusionsAlthough LLTx is a high-risk procedure, both mid- and long-term survival are comparable with LTx in all cohorts in the modern era. LLTx therefore represents a valuable surgical option for small-sized recipients.  相似文献   

10.
ObjectiveAcute hyperglycemia during myocardial infarction worsens outcomes in part by inflammatory mechanisms. Pulsed ultrasound has anti-inflammatory potential in bone healing and neuromodulation. We hypothesized that pulsed ultrasound would attenuate the hyperglycemic exacerbation of myocardial ischemia–reperfusion injury via the cholinergic anti-inflammatory pathway.MethodsAcute hyperglycemia was induced in wild-type C57BL6 or acetylcholine-receptor knockout (α7nAChR-/-) mice by intraperitoneal injection of glucose. Pulsed ultrasound (frequency 7 MHz, bursting mechanical index 1.2, duration 1 second, repeated every 6 seconds for 2 minutes, 20-second total exposure) was performed at the spleen or neck after glucose injection. Separate mice underwent vagotomy before treatment. The left coronary artery was occluded for 20 minutes, followed by 60 minutes of reperfusion. The primary end point was infarct size in explanted hearts.ResultsSplenic pulsed ultrasound significantly decreased infarct size in wild-type C57BL6 mice exposed to acute hyperglycemia and myocardial ischemia–reperfusion injury (5.2% ± 4.4% vs 16.9% ± 12.5% of risk region, P = .013). Knockout of α7nAChR abrogated the beneficial effect of splenic pulsed ultrasound (22.2% ± 12.1%, P = .79 vs control). Neck pulsed ultrasound attenuated the hyperglycemic exacerbation of myocardial infarct size (3.5% ± 4.8%, P = .004 vs control); however, the cardioprotective effect disappeared in mice that underwent vagotomy. Plasma acetylcholine, β2 adrenergic receptor, and phosphorylated Akt levels were increased after splenic pulsed ultrasound treatment.ConclusionsPulsed ultrasound treatment of the spleen or neck attenuated the hyperglycemic exacerbation of myocardial ischemia–reperfusion injury leading to a 3-fold decrease in infarct size. Pulsed ultrasound may provide cardioprotection via the cholinergic anti-inflammatory pathway and could be a promising new nonpharmacologic, noninvasive therapy to reduce infarct size during acute myocardial infarction and improve patient outcomes.  相似文献   

11.
ObjectiveTo determine whether a continuous intravenous infusion of standard amino acids could preserve kidney function after on-pump cardiac surgery.MethodsAdult patients scheduled to receive cardiac surgery lasting longer than 1 hour on-pump were randomized to standard care (n = 36) or an infusion of amino acids initiated immediately after induction of anesthesia (n = 33). The study's primary outcome measurements assessed renal function. These assessments included duration of renal dysfunction, duration and severity of acute kidney injury (AKI), estimated glomerular filtration rate (eGFR) over time, urine output, and use of renal-replacement therapy. Complications and other measures of morbidity were also assessed.ResultsSixty-nine patients (mean age 71.5 [standard deviation 9.2] years; 19 of 69 women) were enrolled and randomized. Patients received coronary artery bypass graft surgery (37/69), valve surgery (24/69), coronary artery bypass graft and valve surgery (6/69), or other procedures (2/69). Mean on-pump time was 268 [standard deviation 136] minutes. Duration of renal dysfunction did not differ between the groups (relative risk, 0.86; 95% confidence interval [CI], 0.19-3.79, P = .84). However, patients who received the amino acid infusion had a reduced duration of AKI (relative risk, 0.02; 95% CI, 0.005-0.11, P < .0001) and greater eGFR (+10.8%; 95% CI, 1.0%-20.8%, P = .033). Daily mean urine output was also significantly greater in patients who received the amino acid infusion (1.4 ± 0.5 vs 1.7 ± 0.9 L/d; P = .046).ConclusionsCommencing an infusion of standard amino acids immediately after the induction of anesthesia did not alter duration of renal dysfunction; however, other key measures of renal function (duration of AKI, eGFR and urine output) were significantly improved. These results warrant replication in multicenter clinical trials.  相似文献   

12.
PurposeTo compare morphological imaging features and CT texture histogram parameters between grade 3 pancreatic neuroendocrine tumors (G3-NET) and neuroendocrine carcinomas (NEC).Materials and methodsPatients with pathologically proven G3-NET and NEC, according to the 2017 World Health Organization classification who had CT and MRI examinations between 2006-2017 were retrospectively included. CT and MRI examinations were reviewed by two radiologists in consensus and analyzed with respect to tumor size, enhancement patterns, hemorrhagic content, liver metastases and lymphadenopathies. Texture histogram analysis of tumors was performed on arterial and portal phase CT images. images. Morphological imaging features and CT texture histogram parameters of G3-NETs and NECs were compared.ResultsThirty-seven patients (21 men, 16 women; mean age, 56 ± 13 [SD] years [range: 28-82 years]) with 37 tumors (mean diameter, 60 ± 46 [SD] mm) were included (CT available for all, MRI for 16/37, 43%). Twenty-three patients (23/37; 62%) had NEC and 14 patients (14/37; 38%) had G3-NET. NECs were larger than G3-NETs (mean, 70 ± 51 [SD] mm [range: 18 - 196 mm] vs. 42 ± 24 [SD] mm [range: 8 - 94 mm], respectively; P = 0.039), with more tumor necrosis (75% vs. 33%, respectively; P = 0.030) and lower attenuation on precontrast (30 ± 4 [SD] HU [range: 25-39 HU] vs. 37 ± 6 [SD] [range: 25-45 HU], respectively; P = 0.002) and on portal venous phase CT images (75 ± 18 [SD] HU [range: 43 - 108 HU] vs. 92 ± 19 [SD] HU [range: 46 - 117 HU], respectively; P = 0.014). Hemorrhagic content on MRI was only observed in NEC (P = 0.007). The mean ADC value was lower in NEC ([1.1 ± 0.1 (SD)] × 10−3 mm2/s [range: (0.91 - 1.3) × 10−3 mm2/s] vs. [1.4 ± 0.2 (SD)] × 10−3 mm2/s [range: (1.1 - 1.6) × 10−3 mm2/s]; P = 0.005). CT histogram analysis showed that NEC were more heterogeneous on portal venous phase images (Entropy-0: 4.7 ± 0.2 [SD] [range: 4.2-5.1] vs. 4.5 ± 0.4 [SD] [range: 3.7-4.9]; P = 0.023).ConclusionPancreatic NECs are larger, more frequently hypoattenuating and more heterogeneous with hemorrhagic content than G3-NET on CT and MRI.  相似文献   

13.
PurposeTo evaluate the potential differences in non-target embolization and vessel microsphere filling of a reflux-control microcatheter (RCM) compared to a standard end-hole microcatheter (SEHM) in a swine model.Materials and methodsRadiopaque microspheres were injected with both RCM and SEHM (2.4-Fr and 2.7-Fr) in the kidneys of a preclinical swine model. Transarterial renal embolization procedures with RCM or SEHM were performed in both kidneys of 14 pigs. Renal arteries were selectively embolized with an automated injection protocol of radio-opaque microspheres. Ex-vivo X-ray microtomography images of the kidneys were utilized to evaluate the embolization by quantification of the deposition of injected microspheres in the target vs. the non-target area of injection. X-ray microtomography images were blindly analyzed by five interventional radiologists. The degree of vessel filling and the non-target embolization were quantified using a scale from 1 to 5 for each parameter. An analysis of variance was used to compare the paired scores.ResultsTotal volumes of radio-opaque microspheres injected were similar for RCM (11.5 ± 3.6 [SD] mL; range: 6–17 mL) and SEHM (10.6 ± 5.2 [SD] mL; range: 4–19 mL) (P = 0.38). The voxels enhanced ratio in the target (T) vs. non-target (NT) areas was greater with RCM (T = 98.3% vs. NT = 1.7%) than with SEHM (T = 89% vs. NT = 11%) but the difference was not significant (P = 0.30). The total score blindly given by the five interventional radiologists was significantly different between RCM (12.3 ± 2.1 [SD]; range: 6–15) and the standard catheter (11.3 ± 2.5 [SD]; range: 4–15) (P = 0.0073), with a significant decrease of non-target embolization for RCM (3.8 ± 1.3 [SD]; range: 3.5–4.2) compared to SEHM (3.2 ± 1.5 [SD]; range: 2.9–3.5) (P = 0.014).ConclusionIn an animal model, RCM microcatheters reduce the risk of non-target embolization from 11% to 1.7%, increasing the delivery of microspheres of 98% to the target vessels, compared to SEHM microcatheters.  相似文献   

14.
PurposeTo compare conventional magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) in the differentiation of bone plasmacytoma from bone metastasis in the extremities.Materials and methodsA total of 65 patients with 27 bone plasmacytomas (11 men; mean age, 63.6 ± 8.2 [SD] years) and 38 patients with bone metastases (20 men; mean age, 64.1 ± 11.5 [SD] years) were retrospectively included. Plasmacytomas and metastases were compared for size, peritumoral edema, signal intensity (SI), SI pattern, apparent diffusion coefficient (ADC) values and standard deviation (SD) of ADC. Receiver operating characteristic analysis with area under the curve (AUC) was used to calculate sensitivity, specificity, and accuracy of MRI and DWI for the diagnosis of plasmacytoma according to a defined cut-off value.ResultsOn conventional MRI, plasmacytomas showed less peritumoral edema (22% vs. 71%; P < 0.001), were more often hyperintense on T1-weighted image (48% vs. 18%; P = 0.022) and more homogeneous on T2-weighted image (78% vs. 26%; P < 0.001) and contrast-enhanced T1-weighted images (70% vs. 25%; P = 0.001) than bone metastases. Mean ADC value and SD of ADC were significantly lower in bone plasmacytomas (760.1 ± 196.9 [SD] μm2/s and 161.5 ± 62.7 [SD], respectively) than in bone metastases (1214.2 ± 382.6 [SD] μm2/s and 277.0 ± 110.3 [SD], respectively) (P < 0.001). Using an ADC value  908.3 μm2/s, DWI yielded 88% sensitivity and 78% specificity for the diagnosis of plasmacytoma. ADC value yielded best area under the curve (AUC = 0.913), followed by SD of ADC (AUC = 0.814) and homogeneity on T2-weighted images (AUC = 0.757). The combination of conventional MRI and DWI (AUC = 0.894) showed improved diagnostic performance over conventional MRI alone (AUC= 0.843) for discriminating between plasmacytoma and metastasis.ConclusionConventional MRI in combination with DWI can be useful to discriminate between bone plasmacytoma and bone metastasis in the extremities.  相似文献   

15.
ObjectiveThe aim of this study was to evaluate comparative outcomes for percutaneous coronary intervention (PCI) versus coronary artery bypass grafting (CABG) in patients with reduced ejection fraction.MethodsAll patients from the University of Pittsburgh Medical Center from 2011 to 2018 who had reduced preoperative ejection fraction (<50%) and underwent CABG or PCI for coronary revascularization were included in this study. Patients were risk-adjusted with propensity matching (1:1) and primary outcomes included long-term survival, readmission, and major adverse cardiac and cerebrovascular events (MACCE).ResultsA total of 2000 patients were included in the current study, consisting of CABG (n = 1553) and PCI (n = 447) cohorts with a mean ejection fraction of 35% ± 9.53%. Propensity matching yielded a 1:1 match with 324 patients in each cohort, controlling for all baseline characteristics. Thirty-day mortality was similar for PCI versus CABG (6.2% vs 4.9%; P = .49). Overall mortality over the study follow-up period (median, 3.23 years; range, 1.83-4.98 years) was significantly higher for the PCI cohort (37.4% vs 21.3%; P < .001). Total hospital readmissions (24.1% vs 12.9%; P = .001), cardiac readmissions (20.4% vs 11.1%; P = .001), myocardial infarction event (7.7% vs 1.8%; P = .001), MACCE (41.4% vs 23.8%; P < .001), and repeat revascularization (6.5% vs 2.6%; P = .02) occurred more frequently in the PCI cohort. Freedom from MACCE at 1 year (74.4% vs 87.0%; P < .001) and 5 years (54.5% vs 74.0%; P < .001) was significantly lower for the PCI cohort. On multivariable cox regression analysis, CABG (hazard ratio, 0.57; 95% confidence interval, 0.44-0.73; P < .001) was significantly associated with improved survival. Prior liver disease, dialysis, diabetes, and peripheral artery disease were the most significant predictors of mortality. The cumulative incidence of hospital readmission was lower for the CABG cohort (hazard ratio, 0.51; 95% confidence interval, 0.37-0.71; P < .001). Multivariable cox regression for MACCE (hazard ratio, 0.48; 95% confidence interval, 0.39-0.58; P < .001) showed significantly fewer events for the CABG cohort.ConclusionsPatients with reduced ejection fraction who underwent CABG had significantly improved survival, lower MACCE, and fewer repeat revascularization procedures compared with patients who underwent PCI.  相似文献   

16.
BackgroundWe investigated outcomes of coronary artery bypass grafting (CABG) with endoscopic vein harvest (EVH) vs open vein harvest (OVH) within the Evaluation of XIENCE Versus CABG (EXCEL) trial.MethodsAll patients in EXCEL randomized to CABG were included in this study. For this analysis, the primary end points were ischemia-driven revascularization (IDR) and graft stenosis or occlusion at 5 years. Additional end points were as follows: a composite of death from any cause, stroke, or myocardial infarction; bleeding; blood product transfusion; major arrhythmia; and infection requiring antibiotics. Event rates were based on Kaplan-Meier estimates in time-to-first-event analyses.ResultsOf the 957 patients randomized to CABG, 686 (71.7%) received at least 1 venous graft with 257 (37.5%) patients in the EVH group and 429 (62.5%) patients in the OVH group. At 5 years, IDR was higher (11.5% vs 6.7%; P = .047) in the EVH group. At 5 years, rates of graft stenosis or occlusion (9.7% vs 5.4%; P = .054) and the primary end point (17.4% vs 20.9%; P = .27) were similar. In-hospital bleeding (11.3% vs 13.8%; P = .35), in-hospital blood product transfusion (12.8% vs 13.1%; P = .94), and infection requiring antibiotics within 1 month (13.6% vs 16.8%; P = .27) were similar between EVH and OVH patients. Major arrhythmia in the hospital (19.8% vs 13.5%; P = .03) and within 1 month (21.8% vs 15.4%; P = .03) was higher in EVH patients.ConclusionsIDR at 5 years was higher in the EVH group. EVH and OVH patients had similar rates of graft stenosis or occlusion and the composite of death, stroke, or myocardial infarction at 5 years.  相似文献   

17.
ObjectiveThe study objective was to analyze the outcomes of thoracic endovascular aortic repair performed for complicated and uncomplicated acute type B aortic dissections.MethodsPatients from WL Gore's Global Registry for Endovascular Aortic Treatment who underwent thoracic endovascular aortic repair for acute type B aortic dissections were included, and data were retrospectively analyzed.ResultsOf 5014 patients enrolled in the Global Registry for Endovascular Aortic Treatment, 172 underwent thoracic endovascular aortic repair for acute type B aortic dissections. Of these repairs, 102 were for complicated acute type B aortic dissections and 70 were for uncomplicated acute type B aortic dissections. There were 46 (45.1%) procedures related to aortic branch vessels versus 15 (21.4%) in complicated type B aortic dissections and uncomplicated type B aortic dissections (P = .002). The mean length of stay was 14.3 ± 10.6 days (median, 11; range, 2-75) versus 9.8 ± 7.9 days (median, 8; range, 0-42) in those with complicated type B aortic dissections versus those with uncomplicated acute type B aortic dissections (P < .001). Thirty-day mortality was not different between groups (complicated type B aortic dissections 2.9% vs uncomplicated acute type B aortic dissections 1.4%, P = .647), as well as aortic complications (8.8% vs 5.7%, P = .449). Aortic event-free survival was 62.9% ± 37.1% versus 70.6% ± 29.3% at 3 years (P = .696).ConclusionsIn the Global Registry for Endovascular Aortic Treatment, thoracic endovascular aortic repair results for complicated type B aortic dissections versus uncomplicated acute type B aortic dissections showed that 30-day mortality and perioperative complications were equally low for both. The midterm outcome was positive. These data confirm that thoracic endovascular aortic repair as the first-line strategy for treating complicated type B dissections is associated with a low risk of complications. Further studies with longer follow-up are necessary to define the role of thoracic endovascular aortic repair in uncomplicated acute type B dissections compared with medical therapy. However, in the absence of level A evidence from randomized trials, results of the uncomplicated acute type B aortic dissection patient cohort treated with thoracic endovascular aortic repair from registries are important to understand the related risk and benefit.  相似文献   

18.
ObjectiveBarlow's disease remains challenging to repair, given the complex valvular morphology and lack of quantitative data to compare techniques. Although there have been recent strides in ex vivo evaluation of cardiac mechanics, to our knowledge, there is no disease model that accurately simulates the morphology and pathophysiology of Barlow's disease. The purpose of this study was to design such a model.MethodsTo simulate Barlow's disease, a cross-species ex vivo model was developed. Bovine mitral valves (n = 4) were sewn into a porcine annulus mount to create excess leaflet tissue and elongated chordae. A heart simulator generated physiologic conditions while hemodynamic data, high-speed videography, and chordal force measurements were collected. The regurgitant valves were repaired using nonresectional repair techniques such as neochord placement.ResultsThe model successfully imitated the complexities of Barlow's disease, including redundant, billowing bileaflet tissues with notable regurgitation. After repair, hemodynamic data confirmed reduction of mitral leakage volume (25.9 ± 2.9 vs 2.1 ± 1.8 mL, P < .001) and strain gauge analysis revealed lower primary chordae forces (0.51 ± 0.17 vs 0.10 ± 0.05 N, P < .001). In addition, the maximum rate of change of force was significantly lower postrepair for both primary (30.80 ± 11.38 vs 8.59 ± 4.83 N/s, P < .001) and secondary chordae (33.52 ± 10.59 vs 19.07 ± 7.00 N/s, P = .006).ConclusionsThis study provides insight into the biomechanics of Barlow's disease, including sharply fluctuating force profiles experienced by elongated chordae prerepair, as well as restoration of primary chordae forces postrepair. Our disease model facilitates further in-depth analyses to optimize the repair of Barlow's disease.  相似文献   

19.
BackgroundLiver cirrhosis is now well recognized as a potential complication after the Fontan procedure, although associated risk factors and optimal timing of liver screening remain unclear.MethodsAll patients who underwent an extracardiac conduit Fontan procedure at The Royal Children’s Hospital, Melbourne, were identified using the Australia and New Zealand Fontan Registry. Cirrhosis was diagnosed based on liver biopsy, or a combination of imaging findings and clinical evaluation by a hepatologist.ResultsBetween 1997 and 2020, 398 patients underwent an extracardiac conduit Fontan procedure at our center, and 276 had ongoing follow-up in Victoria. Ninety-five patients (34%) underwent liver assessment at a mean age of 18.2 ± 6.7 years (11.8 ± 5.5 years post-Fontan). Fifteen patients (16%) were diagnosed with cirrhosis at a mean age of 22.7 ± 5.9 years (14.0 ± 5.2 years post-Fontan). The need for prior or concomitant atrioventricular valve repair or replacement was associated with an increased risk of cirrhosis (univariable hazard ratio [HR] 7.09, 95% confidence interval [CI] 2.13-23.61, P = .001). By multivariable analysis, factors associated with development of cirrhosis were atrioventricular valve failure prior to Fontan (HR 3.27, 95% CI 1.15-9.31, P = .026) and older age at Fontan operation (HR 1.13 per year increase, 95% CI 1.01-1.26, P = .034). The proportion of patients alive, nontransplanted, and without cirrhosis at 10, 15, and 20 years was 93.4% (95% CI 88.4%-98.7%), 79.6% (95% CI 69.7%-90.8%), and 64.6% (95% CI 51.0%-81.9%), respectively.ConclusionsEarly commencement of liver screening should be considered for patients with a history of atrioventricular failure during Fontan palliation.  相似文献   

20.
ObjectiveThe study objective was to determine if hemiarch replacement is an adequate arch management strategy for patients with acute type A aortic dissection and arch branch vessel dissection but no cerebral malperfusion.MethodsFrom January 2008 to August 2019, 479 patients underwent open acute type A aortic dissection repair. After excluding those with aggressive arch replacement (n = 168), cerebral malperfusion syndrome (n = 34), and indeterminable arch branch vessel dissection (n = 1), 276 patients with an acute type A aortic dissection without cerebral malperfusion syndrome who underwent hemiarch replacement comprised this study. Patients were then divided into those with arch branch vessel dissection (n = 133) and those with no arch branch vessel dissection (n = 143).ResultsThe median age of the entire cohort was 62 years, with the arch branch vessel dissection group being younger (60 vs 62 years, P = .048). Both groups had similar aortic arch and descending thoracic aortic diameters, with significantly more DeBakey type I dissections (100% vs 80%) in the arch branch vessel dissection group. The arch branch vessel dissection group had more aortic root replacement (36% vs 27%, P = .0035) and longer aortic crossclamp times (153 vs 128 minutes, P = .007). Postoperative outcomes were similar between the arch branch vessel dissection and no arch branch vessel dissection groups, including stroke (10% vs 5%, P = .12) and operative morality (7% vs 5%, P = .51). The arch branch vessel dissection group had a significantly greater cumulative incidence of reoperation (8-year: 19% vs 4%, P = .04) with a hazard ratio of 2.89 (95% confidence interval, 1.01-8.27; P = .048), which was similar between groups among only DeBakey type I dissections (8-year: 19% vs 5%, P = .11). The 8-year survival was similar between the arch branch vessel dissection and no arch branch vessel dissection groups (76% vs 74%, P = .30).ConclusionsHemiarch replacement was adequate for patients with acute type A aortic dissection with arch branch vessel dissection without cerebral malperfusion syndrome, but carried a higher risk of late reoperation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号